Search NASA⌕ Search

SEARCH · Search NASA

Results for “software validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Erosion resistance test of SiC mirror sample for ITER divertor VUV spectrometer

A series of tests have been performed to validate the resistance of the Silicon Carbide (SiC) mirror as the first mirror material of ITER VUV spectrometers to all ITER environmental conditions. Here we focused on the erosion (and deposition) of the SiC mirror sample caused by high-energy neutral particles. The flux of neutral particles reaching the first mirror was calculated using the ZEMAX software with a simplified entrance duct model. In the calculation, the particle flux reaching the first wall is necessary and the previously reported values derived from the SOLPS calculations were used. Based on this estimated particle flux, the erosion resistance tests were performed to check the erosion effect due to the high-energy neutral particles on the first mirror of ITER divertor VUV spectrometer. In the experiment, erosion was induced by exposing the SiC mirror sample to hydrogen and deuterium plasmas (and ions). The target fluence of incident ions in experiment is based on the estimation of the flux of neutral particles in ITER. The surface shape, composition, erosion depth, and surface roughness were measured to check the damage of the mirror surface after erosion test. Based on simulations and erosion resistance tests, it was concluded that the SiC mirror can be used as the first mirror of ITER divertor VUV spectrometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling and Simulation of Ternary Pumped Storage Hydropower for Power System Studies

As the deployment of wind and solar energy increases in the United States, energy storage (ES) will play an important role in future electric power grids. To help manage the variability from high penetration levels of renewable generation, ES can provide promising power/energy demand to coordinate with renewables generation, as a virtual power plant (VPP). There is an industry need for the capability in power system studies to model ternary pumped storage hydropower (T-PSH) that offers increased system benefits. This paper presents a comprehensive vendor-neutral dynamic model of T-PSH in GE's commercial software positive sequence load flow (PSLF). A new governor model is developed with detailed gate valve modeling and a shared-penstock function. Specifically, this model is designed to simulate the seamless transition among three operation modes: generation mode, pumping mode, and hydraulic short-circuit mode. The developed T-PSH model has been tested and validated on a 10-bus test system. A comparison study of T-PSH to conventional pumped storage hydropower has also been conducted on the Western Interconnection system.

13 HYDRO ENERGY↗

Experience with the alpaka performance portability library in the CMS software

ion Library for Parallel Kernel Acceleration) is a header-only C++ library that provides performance portability across different back-ends, abstracting the underlying levels of parallelism. It supports serial and parallel execution on CPUs, and extremely parallel execution on NVIDIA, AMD and Intel GPUs.This contribution will show how alpaka is used in the CMS software to develop and maintain a single code base; to use different toolchains to build the code for each supported back-end, and link them into a single application; to seamlessly select the best backend at runtime, and implement portable reconstruction algorithms that run efficiently on CPUs and GPUs from different vendors. It will describe the validation and deployment of the alpaka-based implementation in the CMS High Level Trigger, and highlight how it achieves near-native performance.

Alawieh, Jaafar [CERN]↗

Seismic Monitoring To Assess Performance Of Structures In Near-Real Time: Recent Progress

Earlier papers have described how observed data from classical accelerometers deployed in structures or from differential GPS with high sampling ratios deployed at roofs of tall buildings can be configured to establish seismic health monitoring of structures. In these configurations, drift ratios{sup 1} are the main parametric indicator of damage condition of a structure or component of a structure.Real-time measurement of displacements are acquired either by double integration of accelerometer time-series data, or by directly using GPS. Recorded sensor data is then related to the performance level of a building. Performance-based design method stipulates that for a building the amplitude of relative displacement of the roof of a building (with respect to its base) indicates its performance.Usually, drift ratio is computed using relative displacement between two consecutive floors. When accelerometers are used, a specific software is used to compute displacements and drift ratios in realtime by double integration of accelerometer data from several floors. However, GPS-measured relative displacements are limited to being acquired only at the roof with respect to its reference base. Thus, computed drift ratio is the average drift ratio for the whole building. Until recently, the validity of measurements using GPS was limited to long-period structures (T>1 s) because GPS systems readily available were limited to 10-20 samples per seconds (sps) capability. However, presently, up to 50 sps differential GPS systems are available on the market and have been successfully used to monitor drift ratios [1,2]--thus enabling future usefulness of GPS to all types of structures. Several levels of threshold drift ratios can be postulated in order to make decisions for inspections and/or occupancy.Experience with data acquired from both accelerometers and GPS deployments indicates that they are reliable and provide pragmatic alternatives to alert the owners and other authorized parties to make informed decisions and select choices for pre-defined actions following significant events.

58 GEOSCIENCES↗

Metazen – metadata capture for metagenomes

Background: As the impact and prevalence of large-scale metagenomic surveys grow, so does the acute need for more complete and standards compliant metadata. Metadata (data describing data) provides an essential complement to experimental data, helping to answer questions about its source, mode of collection, and reliability. Metadata collection and interpretation have become vital to the genomics and metagenomics communities, but considerable challenges remain, including exchange, curation, and distribution. Currently, tools are available for capturing basic field metadata during sampling, and for storing, updating and viewing it. These tools are not specifically designed for metagenomic surveys; in particular, they lack the appropriate metadata collection templates, a centralized storage repository, and a unique ID linking system that can be used to easily port complete and compatible metagenomic metadata into widely used assembly and sequence analysis tools. Results: Metazen was developed as a comprehensive framework designed to enable metadata capture for metagenomic sequencing projects. Specifically, Metazen provides a rapid, easy-to-use portal to encourage early deposition of project and sample metadata. Conclusion: Metazen is an interactive tool that aids users in recording their metadata in a complete and valid format. A defined set of mandatory fields captures vital information, while the option to add fields provides flexibility.

97 MATHEMATICS AND COMPUTING↗

CSP Systems Analysis - Final Project Report

The CSP Systems Analysis project was a three-year effort supporting the Concentrating Solar Power (CSP) Subprogram within the Solar Energy Technologies Office of the U.S. Department of Energy (DOE). The goal of the CSP Systems Analysis project was to provide timely and accurate CSP cost data to the DOE and predict performance and cost for emerging technologies that may impact research directions and industry investment. The project consisted of six, mostly independent tasks. Major accomplishments over the three-year period of performance were as follows. The NREL team maintained current cost estimates for CSP technologies by annual updates to the cost input parameters within NREL's System Advisor Model (SAM). SAM is a performance and cost simulation software that includes technology models for the primary CSP technologies. During the period from 2016 to 2018, the estimated cost within SAM's default CSP molten-salt power tower technology dropped from 13.0 to 11.1 cent/kWh (real dollars without incentives). Power cycle models for the supercritical carbon dioxide (sCO2) Brayton Cycle were developed and made an option within SAM's molten-salt power tower model. These models were subsequently used to evaluate the cost reduction potential of alternative salts. The partial-cooling model was found to provide the greatest cost-reduction potential due to its combination of efficiency and temperature differential across the turbine and thermal energy storage (TES) system. These studies were documented in two journal articles. NREL's optical modeling software SolTrace and SolarPILOT were made more versatile and released as open-source software to the CSP community. These tools help researchers and developers to model and optimize the optical performance of CSP collector systems. The new features were highlighted in a recorded webinar that can be accessed from the NREL SAM website. New models for solar-thermal systems, that is, applications for solar industrial process heat, were developed, validated, and installed within SAM. The analysis includes a 2018 review of linear collectors in the market that are tailored for solar process heat applications. In 2018 the NREL team also developed an annual simulation for a direct steam generation system integrated with a latent-heat TES system. This analysis was submitted for journal publication. The NREL team continued to support the exchange of information and development of CSP guidelines within the international CSP community of SolarPACES. Much of the work under this project was presented at SolarPACES, including the development of a modeling checklist to help CSP stakeholders standardize the models used for estimating CSP performance and cost. The CSP Systems Analysis project also supported DOE requests for tracking and reporting programmatic targets for the CSP Subprogram.

14 SOLAR ENERGY↗

Providing Experimental Infrastructure for Accelerating Advanced Reactor Demonstrations through the National Reactor Innovation Center

A suite of experimental infrastructure projects has been developed by the National Reactor Innovation Center to accelerate advanced reactor demonstrations and facilitate their development, addressing crucial gaps in data, materials characterization, and modeling. First, the Molten Salt Thermophysical Examination Capability (MSTEC) provides a specialized platform for post-irradiation characterization of molten salt reactor fuel, coolant salts, and structural materials, essential for supporting the design and operation of advanced reactors and future commercial molten salt reactor development and licensing. The Virtual Test Bed (VTB) complements these efforts by leveraging advanced modeling and simulation tools to evaluate reactor performance and safety. Serving as a library of reference models, the VTB offers a database of multiphysics reactor models, facilitating rapid safety evaluations and includes continuous software quality assurance, crucial for accelerating deployment while maintaining reliability. Additionally, the Helium Component Test Facility (HeCTF) addresses the need for high-temperature helium-cooled reactor component testing. As the first-of-its-kind facility in the United States, HeCTF emulates high-temperature gas reactor conditions, reducing time and cost associated with component validation, thereby accelerating reactor development. Finally, In-cell Thermal Creep Frames provide a unique solution for obtaining thermal creep data from irradiated materials, critical for materials qualification and licensing. Developed by the National Reactor Innovation Center, these compact frames enable the examination of previously irradiated materials, overcoming traditional limitations and enhancing the understanding of mechanical properties crucial for reactor development. Collectively, these experimental infrastructure projects form a comprehensive framework aimed at expediting advanced reactor demonstrations, fostering innovation, and ensuring the viability of next-generation nuclear energy solutions.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Comprehensive reaction mechanism for n-butanol pyrolysis and combustion

A detailed reaction mechanism for n-butanol, consisting of 263 species and 3381 reactions, has been generated using the open-source software package, Reaction Mechanism Generator (RMG). The mechanism is tested against recently published data - jet-stirred reactor mole fraction profiles, opposed-flow diffusion flame mole fraction profiles, autoignition delay times, and doped methane diffusion flame mole fraction profiles - and newly acquired n-butanol pyrolysis experiments with very encouraging results. The chemistry of butanal is also validated against autoignition delay times obtained in shock tube experiments. A flux and sensitivity analysis for each simulated dataset is discussed and reveals important reactions where more accurate rate constant estimates were required. New rate constant expressions were computed using quantum chemistry and transition state theory calculations. Furthermore, in addition to comparing the proposed model with the eight datasets, the model is also compared with recently published n-butanol models for three of the datasets. Key differences between the proposed model and the published models are discussed. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TRANSLATE - a Monte Carlo simulation of electron transport in liquid argon

Here, the microphysics of electron and photon propagation in liquid argon is a key component of detector design and calibrations needed to construct and perform measurements within a wide range of particle physics experiments. As experiments grow in scale and complexity, and as the precision of their intended measurements increases, the development of tools to investigate important microphysics effects impacting such detectors becomes necessary. In this paper we present a new time-domain Monte Carlo simulation of electron transport in liquid argon. The simulation models the TRANSport in Liquid Argon of near-Thermal Electrons (TRANSLATE) with the aim of providing a multi-purpose software package for the study and optimization of detector environments, with a particular focus on ongoing and next generation liquid argon neutrino experiments utilizing the time projection chamber technology. TRANSLATE builds on previous work of Wojcik and Tachiya, amongst others, introducing additional processes, including ionization, thus modeling the full range of drift electron scattering interactions. The simulation is validated by benchmarking its performance with swarm parameters from data collected in experimental setups operating in gas and liquid.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tutorial: Crystal orientations and EBSD — Or which way is up?

Electron backscatter diffraction (EBSD) is an automated technique that can measure the orientation of crystals in a sample very rapidly. There are many sophisticated software packages that present measured data. Unfortunately, due to crystal symmetry and differences in the set-up of microscope and EBSD software, there may be accuracy issues when linking the crystal orientation to a particular microstructural feature. In this paper we outline a series of conventions used to describe crystal orientations and coordinate systems. These conventions have been used to successfully demonstrate that a consistent frame of reference is used in the sample, unit cell, pole figure and diffraction pattern frames of reference. We establish a coordinate system rooted in measurement of the diffraction pattern and subsequently link this to all other coordinate systems. A fundamental outcome of this analysis is to note that the beamshift coordinate system needs to be precisely defined for consistent 3D microstructure analysis. This is supported through a series of case studies examining particular features of the microscope settings and/or unambiguous crystallographic features. These case studies can be generated easily in most laboratories and represent an opportunity to demonstrate confidence in use of recorded orientation data. Finally, we include a simple software tool, written in both MATLAB® and Python, which the reader can use to compare consistency with their own microscope set-up and which may act as a springboard for further offline analysis. - Highlights: • Presentation of conventions used to describe crystal orientations • Three case studies that outline how conventions are consistent • Demonstrates a pathway for calibration and validation of EBSD based orientation measurements • EBSD computer code supplied for validation by the reader.

36 MATERIALS SCIENCE↗

SU-E-J-173: Evaluation of Deformable Registration for Correcting Respiratory Motion in 4DCT Lung Images

Purpose: Deformable Image Registration (DIR) is gaining wider clinical acceptance in radiation oncology. The aim of this work is to characterise a DIR algorithm on publically available 4DCT lung images, such that comparison can be performed against other algorithms. We propose an evaluation method of registration accuracy that takes into account the initial misregistration of the datasets. Methods: The “DIR Validation dataset” ( http://www.creatis.insa-lyon.fr/rio/dir{sub v}alidation{sub d}ata ) provides benchmark data for evaluating 3D CT registration algorithms. It consists of six 4DCT lung datasets (1x1x2mm resolution) with 100 landmarks identified on the end-exhalation and end-inhalation phases. Images were registered to end-inhalation using proprietary form of optical flow in commercial software (Mirada RTx, Mirada Medical, UK). Target registration error was measured before and after DIR, referred to as Initial Registration Error (IRE) and Final Registration Error (FRE). Results: The mean FRE over all landmarks was 1.37±1.81mm. FRE increased with IRE. Mean FRE of 0.86, 0.86, 1.53, 3.38, 4.45, 7.58mm was observed for IRE in the ranges 0–5, 5–10, 10–15, 15–20, 20–25, >25 mm. Higher FRE was observed at the inferior lung, where IRE was greater. Out-of-plane motion contributed more to IRE, and therefore to FRE. Maximum FRE of 20.6mm was observed for IRE of 32.1mm, located at the posterior of the middle lobe for dataset 2. Sub-voxel registration accuracy was achieved for up to 10mm IRE, and increased linearly at 0.3mm FRE/mm IRE thereafter. Conclusion: Publicly available clinical datasets enable algorithms to be compared objectively between publications. However, only reporting average TRE after registration can be misleading as the ability of an algorithm to correct for displacements varies with the IRE or position within the patient. Consequently, algorithms should be characterized using the entire range of initial displacements. For the algorithm assessed, clinically acceptable error within one voxel was achieved for IRE of up to 15mm. TK, AL, and MG are employees of Mirada Medical.

60 APPLIED LIFE SCIENCES↗

TH-C-BRD-04: Beam Modeling and Validation with Triple and Double Gaussian Dose Kernel for Spot Scanning Proton Beams

Purpose: To present the validity of our beam modeling with double and triple Gaussian dose kernels for spot scanning proton beams in Nagoya Proton Therapy Center. This study investigates the conformance between the measurements and calculation results in absolute dose with two types of beam kernel. Methods: A dose kernel is one of the important input data required for the treatment planning software. The dose kernel is the 3D dose distribution of an infinitesimal pencil beam of protons in water and consists of integral depth doses and lateral distributions. We have adopted double and triple Gaussian model as lateral distribution in order to take account of the large angle scattering due to nuclear reaction by fitting simulated inwater lateral dose profile for needle proton beam at various depths. The fitted parameters were interpolated as a function of depth in water and were stored as a separate look-up table for the each beam energy. The process of beam modeling is based on the method of MDACC [X.R.Zhu 2013]. Results: From the comparison results between the absolute doses calculated by double Gaussian model and those measured at the center of SOBP, the difference is increased up to 3.5% in the high-energy region because the large angle scattering due to nuclear reaction is not sufficiently considered at intermediate depths in the double Gaussian model. In case of employing triple Gaussian dose kernels, the measured absolute dose at the center of SOBP agrees with calculation within ±1% regardless of the SOBP width and maximum range. Conclusion: We have demonstrated the beam modeling results of dose distribution employing double and triple Gaussian dose kernel. Treatment planning system with the triple Gaussian dose kernel has been successfully verified and applied to the patient treatment with a spot scanning technique in Nagoya Proton Therapy Center.

07 ISOTOPE AND RADIATION SOURCES↗

LoTToR: An Algorithm for Missing-Wedge Correction of the Low-Tilt Tomographic 3D Reconstruction of a Single-Molecule Structure (LoTToR) v1.0

The low-tilt tomographic reconstruction (LoTToR) method is a post-processing method to correct the missing-wedge artifact, which contains a model-free iteration process under a set of constraints in real and reciprocal spaces. A proof of concept is conducted by using the LoTToR on a phantom, i.e., a simulated 3D reconstruction from a low-tilt series of images, including that within a tilt range of ±15°. The method is validated by using both negative-staining (NS) and cryo-electron tomography (cryo-ET) experimental data. A significantly reduced missing-wedge artifact verifies the capability of LoTToR, suggesting a new tool to support the future study of macromolecular dynamics, fluctuation and chemical activity from the viewpoint of single-molecule 3D structure determination. Moreover, the software can be used for hospital computer tomography (CT) to reduce the radiation damage to patients without reducing the CT image quality.

Ren, Gang↗

Aeroelastic Modeling for Distributed Wind Turbines: March 11, 2021 - November 10, 2021

Aeroelastic modeling (AM) is the primary methodology for structural and performance assessment of any wind turbine whereby providing an understanding of the impact of design parameters on its loading and power response before witnessing it in the field. Despite these advantages, the use of AM in the Distributed Wind Technology (DWT) sector is limited, especially within the less established manufacturers. This project represents an in-depth assessment of the status of AM and its role within the Standards for the DWT industry. The study gathered input and feedback from a large number of national and international stakeholders, reviewed technical strengths and weaknesses of the current edition of the design standards, analyzed recent industry workshops' and meetings' minutes, collected publicly available AM templates, and provided an evaluation of the existing AM codes. The study achieved several goals including providing strategies for the load assessment categorization of turbines based on rotor swept area and archetype, and guidance for AM verification and validation (V&V), which includes discussions of measurement requirements and a sample test-plan useful for future V&V campaigns and design standard development. This document summarizes the different tasks conducted in the course of the project and highlights the steps required to improve the AM adoption based on a multifaceted approach that encompasses: 1) augmenting AM software capabilities, 2) publishing AM best-practices and design-basis, 3) creating new model templates, 4) providing guidance for V&V of codes and specific turbine models leveraging field testing best-practice, and 5) addressing weaknesses in the current standards. Many of the future objectives identified in this study could leverage NREL's upcoming testing campaigns of three modern distributed wind turbines. Recommendations within this study will advance the value and the ease-of-use of AM, thereby allowing the industry to better capitalize this underutilized tool resulting in a more efficient design process, an easier path to certification, and overall better and more distributed reliable wind turbine products.

17 WIND ENERGY↗

Portable HCAL reconstruction in the CMS detector using the Alpaka library

CMS has deployed a number of different GPU algorithms at the High-Level Trigger (HLT) in Run 3. As the code base for GPU algorithms continues to grow, the burden for developing and maintaining separate implementations for GPU and CPU becomes increasingly challenging. To mitigate this, CMS has adopted the Alpaka (Abstraction Library for Parallel Kernel Acceleration) library as the performance portability solution to provide a single-code base for parallel execution on both GPUs and CPUs in CMS software (CMSSW). A direct CUDA version of HCAL energy reconstruction, called Minimization At Hcal, Iteratively (MAHI), has been deployed at the HLT in the 2022-2023 data taking period. This contribution will describe how the CUDA version is converted into a portable implementation using the Alpaka library. We will discuss the porting experience from CUDA to Alpaka, the validation process and the performance of the Alpaka version in CPU and GPU.

Kwok, Martin↗

Evaluation of left ventricular mass on cadmium-zinc-telluride imaging: Validation against cardiac magnetic resonance

Background: Single-photon emission computed tomography has shown relevant limitations in the quantification of left ventricular (LV) mass. We sought to compare the estimates of LV mass on Cadmium-Zinc-Telluride (CZT) myocardial perfusion imaging (MPI) as compared to cardiac magnetic resonance (CMR). Methods and results: Twenty-five patients underwent MPI on a CZT camera and CMR on a 1.5 T scanner within 12 ± 3 weeks. LV mass was quantified on CZT images using two softwares: 4D-MSPECT (4DM) and Emory Cardiac Toolbox (ECTb). LV mass by CMR was quantified using MASS software (Medis, Leiden, The Netherlands). LV mass values obtained with 4DM and ECTb were highly reproducible [intraclass correlation coefficients .98 (95% CI .97-.99), and .98 (95% CI 0.97-.99), respectively]. The mean LVM mass values were 151 ± 44 g on CMR, 151 ± 43 g with 4DM (P = NS vs CMR), and 157 ± 42 g with ECTb (P < .001 vs CMR; P = .007 vs 4DM) CZT images. There was an excellent correlation between LV mass values between CMR and both 4DM (R{sup 2} = .95; P < .001) and ECTb (R{sup 2} = .98; P < .001) with narrow limits of agreement (− 13.6% to + 13.4% for 4DM, and − 5.6% to + 14.1% for ECTb). Conclusions: The evaluation of LV mass is feasible on CZT images, showing excellent agreement with CMR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Precipitation Estimate Using NEXRAD Ground-Based Radar Images: Validation, Calibration and Spatial Analysis

Precipitation is an important input variable for hydrologic and ecological modeling and analysis. Next Generation Radar (NEXRAD) can provide precipitation products that cover most of the continental United States with a high resolution display of approximately 4 × 4 km2. Two major issues concerning the applications of NEXRAD data are (1) lack of a NEXRAD geo-processing and geo-referencing program and (2) bias correction of NEXRAD estimates. In this chapter, a geographic information system (GIS) based software that can automatically support processing of NEXRAD data for hydrologic and ecological models is presented. Some geostatistical approaches to calibrating NEXRAD data using rain gauge data are introduced, and two case studies on evaluating accuracy of NEXRAD Multisensor Precipitation Estimator (MPE) and calibrating MPE with rain-gauge data are presented. The first case study examines the performance of MPE in mountainous region versus south plains and cold season versus warm season, as well as the effect of sub-grid variability and temporal scale on NEXRAD performance. From the results of the first case study, performance of MPE was found to be influenced by complex terrain, frozen precipitation, sub-grid variability, and temporal scale. Overall, the assessment of MPE indicates the importance of removing bias of the MPE precipitation product before its application, especially in the complex mountainous region. The second case study examines the performance of three MPE calibration methods using rain gauge observations in the Little River Experimental Watershed in Georgia. The comparison results show that no one method can perform better than the others in terms of all evaluation coefficients and for all time steps. For practical estimation of precipitation distribution, implementation of multiple methods to predict spatial precipitation is suggested.

Zhang, Xuesong↗

MO-C-17A-05: A Three-Dimensional Head-And-Neck Phantom for Validation of Kilovoltage- and Megavoltage-Based Deformable Image Registration

Purpose: To develop a three-dimensional (3D) deformable head-and-neck (H and N) phantom with realistic tissue contrast for both kilovoltage and megavoltage computed tomography and use it to objectively evaluate deformable image registration (DIR) algorithms. Methods: The phantom represents H and N patient anatomy. It is constructed from thermoplastic, which becomes pliable in boiling water, and hardened epoxy resin. Using a system of additives, the Hounsfield unit (HU) values of these materials were tuned to mimic anatomy for both kilovoltage (kV) and megavoltage (MV) imaging. The phantom opened along a sagittal midsection to reveal nonradiopaque markers, which were used to characterize the phantom deformation. The deformed and undeformed phantom was scanned with kV and MV computed tomography. Additionally, a calibration curve was created to change the HUs of the MV scans to be similar to kV HUs, (MC). The extracted ground-truth deformation was then compared to the results of two commercially available DIR algorithms, from Velocity Medical Solutions and MIM Software. Results: The phantom produced a 3D deformation, representing neck flexion, with a magnitude of up to 8 mm and was able represent tissue HUs for both kV and MV imaging modalities. The two tested deformation algorithms yielded vastly different results. For kV-kV registration, MIM made the lowest mean error, and Velocity made the lowest maximum error. For MV-MV, kV-MV, and kV-MC Velocity produced both the lowest mean and lowest maximum errors. Conclusion: The application of DIR across different imaging modalities is particularly difficult, due to differences in tissue HUs and the presence of imaging artifacts. For this reason, DIR algorithms must be validated specifically for this purpose. The developed H and N phantom is an effective tool for this purpose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗