Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface contamination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Land use change detection with LANDSAT-2 data for monitoring and predicting regional water quality degradation

The author has identified the following significant results. Comparison between LANDSAT 1 and 2 imagery of Arkansas provided evidence of significant land use changes during the 1972-75 time period. Analysis of Arkansas historical water quality information has shown conclusively that whereas point source pollution generally can be detected by use of water quality data collected by state and federal agencies, sampling methodologies for nonpoint source contamination attributable to surface runoff are totally inadequate. The expensive undertaking of monitoring all nonpoint sources for numerous watersheds can be lessened by implementing LANDSAT change detection analyses.

Macdonald, H.↗

Landsat change detection can aid in water quality monitoring

Comparison between Landsat-1 and -2 imagery of Arkansas provided evidence of significant land use changes during the 1972-75 time period. Analysis of Arkansas historical water quality information has shown conclusively that whereas point source pollution generally can be detected by use of water quality data collected by state and federal agencies, sampling methodologies for nonpoint source contamination attributable to surface runoff are totally inadequate. The expensive undertaking of monitoring all nonpoint sources for numerous watersheds can be lessened by implementing Landsat change detection analyses.

Macdonald, H. C.↗

Reactivity of stratospheric aerosols to small amounts of ammonia in the laboratory environment

Trace ammonia in laboratory air reacts easily with sulfuric acid aerosol samples to form crystalline ammonium sulfate. Argon atmospheres, however, protect sampling surfaces from ammonia contamination. It is found that atmospheric aerosols treated in this way contain only sulfuric acid. After an hour exposed to laboratory air, these same samples convert to ammonium sulfate. Aerosol particles have been collected, using argon control, to determine if the absence of crystalline sulfate is common. But so far there is no evidence that aerosols are neutralized by ammonia in the stratosphere.

Hayes, D.↗

Defect studies in one MeV electron irradiated GaAs and in Al/sub x Ga/sub l-x As P-N junction solar cells

Deep level transient spectroscopy reveals that the main electron traps for one-MeV electron irradiated GaAs cells are E9c)-0.31, E(c)-0.90 eV, and the main hole trap is due to the level. Electron trap density was found to vary from 3/tens-trillion ccm for 2/one quadrillion cm 3/3.7 quadrillion cm for 21 sextillion cm electron fluence for electron fluence; a similar result was also obtained for the hole trap density. As for the grown-in defects in the Al(x)Ga(1-x)As p-n junciton cells, only two electron traps with energies of E(c)-0.20 and E(c)-0.34 eV were observed in samples with x = 0.17, and none was found for x 0.05. Auger analysis on the Al(x)Ga(1-x) As window layer of the GaAs solar cell showed a large amount of oxygen and carbon contaminants near the surface of the AlGaAs epilayer. Thermal annealing experiment performed at 250 C for up to 100 min. showed a reduction in the density of both electron traps.

Li, S. S.↗

Use of a 35mm camera for remote surface cleanliness verification

Non-contact or remote monitoring of surfaces for both particle and molecular contaminants is required for verification of surface cleanliness on many program subsystems. The capability of a 35mm camera to satisfy this need is presented. The many limitations imposed by standard available lens systems are compared to actual required sensitivities. Methods of optimizing camera systems for specific applications and descriptions of support systems for extending the range of usefulness of the recorded data are also provided. Although this general concept is not new, significant improvements in the technique involving the use of polarized light and diffraction effects have resulted in a more efficient utilization of information recorded on the film.

Crutcher, E. R.↗

Design and demonstration of a system for the deposition of atomic-oxygen durable coatings for reflective solar dynamic power system concentrators

A system for the vacuum deposition of atomic-oxygen durable coatings for reflective solar dynamic power systems (SDPS) concentrators was designed and demonstrated. The design issues pertinent to SDPS were developed by the Government Aerospace Systems Division of the Harris Corporation and are described in NASA-CR-179489. Both design and demonstration phases have been completed. At the time of this report the deposition system was ready for coating of facets for SDPS concentrators. The materials issue relevant to the coating work were not entirely resolved. These issues can only be resolved when substrates which are comparable to those which will be used in flight hardware are available. The substrates available during the contract period were deficient in the areas of surface roughness and contamination. These issues are discussed more thoroughly in the body of the report.

Mcclure, Donald J.↗

Contamination effects of GPS Navstar solar array performance

The solar arrays on Navstars 1 to 6 have been limiting the electrical power capabilities in the extended life (beyond the 5 year design life). The departure from predicted performance consists of an extra 2.5 percent per year degradation beyond the radiation model estimates. This degradation is unusual in showing a linear rather than exponential decay with time. The performance of the arrays on these satellites has been examined in order to predict future behavior and to make refined projections on the Navstar 7 to 11 solar arrays. Evidence obtained from flight experiments on Navstar 5 and 6, and from laboratory experiments, suggests that contamination of the solar arrays while on orbit may be responsible. The evidence for photo-induced contamination of spacecraft surfaces is presented, and the effect on solar array output in the case of the GPS satellites is shown to be consistent with the observed anomalies.

Marvin, Dean C.↗

Measuring Weld Profiles By Computer Tomography

Noncontacting, nondestructive computer tomography system determines internal and external contours of welded objects. System makes it unnecessary to take metallurgical sections (destructive technique) or to take silicone impressions of hidden surfaces (technique that contaminates) to inspect them. Measurements of contours via tomography performed 10 times as fast as measurements via impression molds, and tomography does not contaminate inspected parts.

Pascua, Antonio G.↗

Preliminary drop-tower experiments on liquid-interface geometry in partially filled containers at zero gravity

Plexiglass containers with rounded trapezoidal cross sections were designed and built to test the validity of Concus and Finn's existence theorem (1974, 1983) for a bounded free liquid surface at zero gravity. Experiments were carried out at the NASA Lewis two-second drop tower. Dyed ethanol-water solutions and three immiscible liquid pairs, with one liquid dyed, were tested. High-speed movies were used to record the liquid motion. Liquid rose to the top of the smaller end of the containers when the contact angle was small enough, in agreement with the theory. Liquid interface motion demonstrated a strong dependence on physical properties, including surface roughness and contamination.

Smedley, G.↗

A review of nuclear electric propulsion spacecraft system concepts

The last 25-30 years of system concepts and design philosophies for spacecraft employing nuclear-electric propulsion (NEP) are reviewed. NEP spacecraft-system design constraints and criteria are identified, including radiation exposure of humans and electronics, thermal control requirements, effluent contamination of spacecraft surfaces, surface erosion, launch-vehicle integration, operations and safety requirements, attitude control, EM interference, and power control and distribution. The impact on spacecraft design philosophy of these constraints and criteria is explored. Several NEP spacecraft are characterized and discussed with respect to the propulsion system used. The electric propulsion system catagories are electrothermal (arcjet), EM (magnetoplasmadynamic and pulsed-inductive thruster) and electrostatic (ion engine). A brief summary of the mission, nuclear power source, electric propulsion system, and spacecraft configuration are provided for each NEP spacecraft concept.

Deininger, W. D.↗

The effect of nitrogen on xenon ion engine erosion

Erosion studies were performed on a 30-cm diameter J-series ion engine modified for operation on xenon propellant. The erosion rates of molybdenum and tantalum badges placed at different locations within the discharge chamber were measured as a function of the percentage of nitrogen (by mass) added to the xenon propellant. Reductions in the erosion rates of these badges of a factor of 8 to 50 were observed at nitrogen addition fractions between 0.5 to 2.0 percent. Reductions in cathode-side baffle erosion were achieved by adding nitrogen to the xenon propellant or by increasing the cathode orifice diameter. Analyses show that no significant degradation in ion engine performance should be expected at these nitrogen mass fractions. XRD, XPS and Auger analyses indicate the existence of nitrogen and nitrides in the surface of some but not all of the badges used in the tests where nitrogen was added to the xenon. Difficulty in identifying surface nitrides in the samples may be due to the existence of surface oxides and contaminants, or to the small thicknesses of the nitride layers.

Garner, Charles E.↗

Measurement realities of current collection in dynamic space plasma environments

Theories which describe currents collected by conducting and non-conducting bodies immersed in plasmas have many of their concepts based upon the fundamentals of sheath-potential distributions and charged-particle behavior in superimposed electric and magnetic fields. Those current-collecting bodies (or electrodes) may be Langmuir probes, electric field detectors, aperture plates on ion mass spectrometers and retarding potential analyzers, or spacecraft and their rigid and tethered appendages. Often the models are incomplete in representing the conditions under which the current-voltage characteristics of the electrode and its system are to be measured. In such cases, the experimenter must carefully take into account magnetic field effects and particle anisotropies, perturbations caused by the current collection process itself and contamination on electrode surfaces, the complexities of non-Maxwellian plasma distributions, and the temporal variability of the local plasma density, temperature, composition and fields. This set of variables is by no means all-inclusive, but it represents a collection of circumstances guaranteed to accompany experiments involving energetic particle beams, plasma discharges, chemical releases, wave injection and various events of controlled and uncontrolled spacecraft charging. Here, an attempt is made to synopsize these diagnostic challenges and frame them within a perspective that focuses on the physics under investigation and the requirements on the parameters to be measured. Examples include laboratory and spaceborne applications, with specific interest in dynamic and unstable plasma environments.

Szuszczewicz, Edward P.↗

Electrical system/environment interactions on the planet Mars

The Martian environment is a diverse environment with which systems will interact in numerous ways. Preliminary thoughts on electrical system/environment interactions which might be of interest to system designers at all stages of system design are presented. These interactions are primarily related to electrical charging, contamination, and Martian surface sand and dust.

Kolecki, J. C.↗

Erosion rates for polymers measured on LDEF

The summary and viewgraphs of work presented at the Long Duration Exposure Facility (LDEF) materials workshop are given. Experimental data for erosion depths and rates for polymers measured on LDEF are given. In general, agreement is reasonably good between erosion rates from the University of Alabama in Huntsville (UAH) LDEF experiment and prior data obtained at much lower mission fluences. Agreement is particularly satisfying in the case of Kapton where the prior data base is large. In spite of the known presence of silicaceous contamination on LDEF surfaces, the erosion rates of the highly erodible materials are hardly affected, if at all. Graphs showing changes in optical properties (reflectance and transmittance) of metal films are included.

Gregory, John C.↗

ASRM Process Development in Aqueous Cleaning

Viewgraphs are included on process development in aqueous cleaning which is taking place at the Aerojet Advanced Solid Rocket Motor (ASRM) Division under a NASA Marshall Space and Flight Center contract for design, development, test, and evaluation of the ASRM including new production facilities. The ASRM will utilize aqueous cleaning in several manufacturing process steps to clean case segments, nozzle metal components, and igniter closures. ASRM manufacturing process development is underway, including agent selection, agent characterization, subscale process optimization, bonding verification, and scale-up validation. Process parameters are currently being tested for optimization utilizing a Taguci Matrix, including agent concentration, cleaning solution temperature, agitation and immersion time, rinse water amount and temperature, and use/non-use of drying air. Based on results of process development testing to date, several observations are offered: aqueous cleaning appears effective for steels and SermeTel-coated metals in ASRM processing; aqueous cleaning agents may stain and/or attack bare aluminum metals to various extents; aqueous cleaning appears unsuitable for thermal sprayed aluminum-coated steel; aqueous cleaning appears to adequately remove a wide range of contaminants from flat metal surfaces, but supplementary assistance may be needed to remove clumps of tenacious contaminants embedded in holes, etc.; and hot rinse water appears to be beneficial to aid in drying of bare steel and retarding oxidation rate.

Swisher, Bill↗

The bromine content of micrometeorites - Arguments for stratospheric contamination

Bromine-salt nanocrystals are associated with a porous chondritic micrometeorite (W7029E5) that was collected in the lower stratosphere. These salt nanocrystals occur together with volcanic Na and K salt nanocrystals embedded in sulfuric acid droplets that were originally adhered to the particle. These materials were concentrated during hexane rinsing as part of routine curation procedures at the NASA Johnson Space Center Cosmic Dust Curatorial Facility. This observation is fortuitous to the extent that the concentration of nanocrystals and sulfuric acid is an experimental artifact of curation. If bromine is a stratospheric contaminant due to surface adsorption, there should be a positive linear relationship between the mass-normalized residence time and bromine content of individual micrometeorites. I show that the predicted correlation exists using a new model to calculate the stratospheric residence time of individual nonspherical micrometeorites in the slow-settling Wilson-Huang regime of the stratosphere.

Rietmeijer, Frans J. M.↗

Hydrophobic Porous Material Adsorbs Small Organic Molecules

Composite molecular-sieve material has pore structure designed specifically for preferential adsorption of organic molecules for sizes ranging from 3 to 6 angstrom. Design based on principle that contaminant molecules become strongly bound to surface of adsorbent when size of contaminant molecules is nearly same as that of pores in adsorbent. Material used to remove small organic contaminant molecules from vacuum systems or from enclosed gaseous environments like closed-loop life-support systems.

Sharma, Pramod K.↗