Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Measurements of liquid and glass structures using in-situ high energy x-ray and neutron scattering

Investigation of high temperature molten materials and their evolution to the amorphous state is often hampered by unwanted reactions with container surfaces. This work used aerodynamic levitation in combination with laser beam heating to study high melting point materials that can form supercooled liquids or glasses. Details of the instruments that are being used at the Advanced Photon Source and the Spallation Neutron Source to study molten oxides with high energy x-ray scattering and neutron diffraction with isotope substitution are presented. Examples of measurements are used to illustrate the use of the instruments. Plans for further development and application of the capabilities are presented.

Weber, Richard↗

Plasmonic trace sensing below the photon shot noise limit

Plasmonic sensors are important detectors of biochemical trace compounds, but those that utilize optical readout are approaching their absolute limits of detection as defined by the Heisenberg uncertainty principle in both differential intensity and phase readout. However, the use of more general minimum uncertainty states in the form of squeezed light can push the noise floor in these sensors below the shot noise limit (SNL) in one analysis variable at the expense of another. Here, we demonstrate a quantum plasmonic sensor whose noise floor is reduced below the SNL in order to perform index of refraction measurements with sensitivities unobtainable with classical plasmonic sensors. The increased signal-to-noise ratio can result in faster detection of analyte concentrations that were previously lost in the noise. As a result, these benefits are the hallmarks of a sensor exploiting quantum readout fields in order to manipulate the limits of the Heisenberg uncertainty principle.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of tip shape on line edge roughness measurement based on atomic force microscopy

Atomic force microscopy (AFM) is an important tool in line edge roughness (LER) measurements, where accuracy for line edge identification is influenced by the shape of the tip. In this article, the effect of tip shape on LER measurement based on AFM is studied theoretically. The formulas for calculating the distance between the measured and actual line edge of the sample are presented. The effects of the three kinds of tips with different shapes are experimentally compared for validation. Suggestions on how to reduce measuring error caused by tip shape are also given.

36 MATERIALS SCIENCE↗

Calcium and lithium ion production for laser ion source

Calcium and lithium ion beams are required by NASA Space Radiation Laboratory at Brookhaven National Laboratory to simulate the effects of cosmic radiation. To identify the difficulties in providing such highly reactive materials as laser targets, both species were experimentally tested. Plate shaped lithium and calcium targets were fabricated to create ablation plasmas with a 6 ns 1064 nm neodymium-doped yttrium aluminum garnet laser. We found significant oxygen contamination in both the Ca and Li high charge state beams due to the rapid oxidation of the surfaces. A large spot size, low power density laser was used to create low charge state beams without scanning the targets. The low charge state Ca beam did not have any apparent oxygen contamination, showing the potential to clean the target entirely of oxide with a low power beam once in the chamber. The Li target was clearly still oxidizing in the chamber after each low power shot. To measure the rate of oxidation, we shot the low power laser at the target repeatedly at 10 s, 30 s, 60 s, and 120 s interval lengths, showing a linear relation between the interval time and the amount of oxygen in the beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE EARLY STAGES OF STAR FORMATION IN INFRARED DARK CLOUDS: CHARACTERIZING THE CORE DUST PROPERTIES

Identified as extinction features against the bright Galactic mid-infrared background, infrared dark clouds (IRDCs) are thought to harbor the very earliest stages of star and cluster formation. In order to better characterize the properties of their embedded cores, we have obtained new 24 {mu}m, 60-100 {mu}m, and submillimeter continuum data toward a sample of 38 IRDCs. The 24 {mu}m Spitzer images reveal that while the IRDCs remain dark, many of the cores are associated with bright 24 {mu}m emission sources, which suggests that they contain one or more embedded protostars. Combining the 24 {mu}m, 60-100 {mu}m, and submillimeter continuum data, we have constructed broadband spectral energy distributions (SEDs) for 157 of the cores within these IRDCs and, using simple graybody fits to the SEDs, have estimated their dust temperatures, emissivities, opacities, bolometric luminosities, masses, and densities. Based on their Spitzer/Infrared Array Camera 3-8 {mu}m colors and the presence of 24 {mu}m point-source emission, we have separated cores that harbor active, high-mass star formation from cores that are quiescent. The active 'protostellar' cores typically have warmer dust temperatures and higher bolometric luminosities than the more quiescent, perhaps 'pre-protostellar', cores. Because the mass distributions of the populations are similar, however, we speculate that the active and quiescent cores may represent different evolutionary stages of the same underlying population of cores. Although we cannot rule out low-mass star formation in the quiescent cores, the most massive of them are excellent candidates for the 'high-mass starless core' phase, the very earliest in the formation of a high-mass star.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurable radiation levels around individuals externally contaminated by nuclear fallout

During the early response to large-scale radioactive contamination events, people who are potentially affected need to be screened for radioactive contamination and public health staff need to triage individuals who may need immediate decontamination. This is typically done by screening individuals for external contamination using ionising radiation detection equipment. In this study, spatially and temporally dependent isotopic compositions from a simulated nuclear detonation and Monte Carlo methods were used to relate contamination activity levels to the measurable radiation levels at select distances away from an individual with whole-body contamination. Radionuclide-specific air kerma rate coefficients and Geiger–Mueller instrument response coefficients at five select distances from contaminated individuals are presented for 662 radionuclides. Temporally and spatially dependent incident-specific coefficients are presented for a hypothetical surface detonation of a 235 U-fueled device.

61 RADIATION PROTECTION AND DOSIMETRY↗

Significant Improvements in Pyranometer Nighttime Offsets Using High-Flow DC Ventilation

Abstract Ventilators are used to keep the domes of pyranometers clean and dry, but they affect the nighttime offset as well. This paper examines different ventilation strategies. For the several commercial single-black-detector pyranometers with ventilators examined here, high-flow-rate [50 cubic feet per minute (CFM) and higher] 12-VDC (where VDC refers to voltage direct current) fans lower the offsets, lower the scatter, and improve the predictability of the offsets during the night compared with lower-flow-rate (35 CFM) 120-VAC (where VAC refers to voltage alternating current) fans operated in the same ventilator housings. Black-and-white pyranometers sometimes show improvement with DC ventilation, but in some cases DC ventilation makes the offsets slightly worse. Since the offsets for these black-and-white pyranometers are always small, usually no more than 1 W m−2, whether AC or DC ventilated, changing their ventilation to higher CFM DC ventilation is not imperative. Future work should include all major manufacturers of pyranometers and unventilated and ventilated pyranometers. An important outcome of future research will be to clarify under what circumstances nighttime data can be used to predict daytime offsets.

14 SOLAR ENERGY↗

Report on the Second ARM Mobile Facility (AMF2) Roll, Pitch, and Heave (RPH) Stabilization Platform: Design and Evaluation

One of the primary objectives of the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) Climate Research Facility’s second Mobile Facility (AMF2) is to obtain reliable measurements of solar, surface, and atmospheric radiation, as well as cloud and atmospheric properties, from ocean-going vessels. To ensure that these climatic measurements are representative and accurate, many AMF2 instrument systems are designed to collect data in a zenith orientation. A pillar of the AMF2 strategy in this effort is the use of a stable platform. The purpose of the platform is to 1) mitigate vessel motion for instruments that require a truly vertical orientation and keep them pointed in the zenith direction, and 2) allow for accurate positioning for viewing or shading of the sensors from direct sunlight. Numerous ARM instruments fall into these categories, but perhaps the most important are the vertically pointing cloud radars, for which vertical motions are a critical parameter. During the design and construction phase of AMF2, an inexpensive stable platform was purchased to perform the stabilization tasks for some of these instruments. The first table compensated for roll, pitch, and yaw (RPY) and was reported upon in a previous technical report (Kafle and Coulter, 2012). Subsequently, a second table was purchased specifically for operation with the Marine W-band cloud radar (MWACR). Computer programs originally developed for RPY were modified to communicate with the new platform controller and with an inertial measurements platform that measures true ship motion components (roll, pitch, yaw, surge, sway, and heave). This platform could not be tested dynamically for RPY because of time constraints requiring its deployment aboard the container ship Horizon Spirit in September 2013. Hence the initial motion tests were conducted on the initial cruise. Subsequent cruises provided additional test results. The platform, as tested, meets all the design and performance criteria established for its use. This is a report of the results of those efforts and the critical points in moving forward

54 ENVIRONMENTAL SCIENCES↗

Observations and Modeling of the Green Ocean Amazon 2014/15: Parsivel2 Field Campaign Report

One of the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility’s Parsivel2 disdrometers was deployed at the first ARM Mobile Facility (AMF1) T3 site in Manacapuru, Brazil at the beginning of the second Green Ocean Amazon (GoAmazon)2014/15 intensive operational period (IOP2) in September 2014 through the end of the field campaign in December 2015. The Parsivel2 provided one-minute drop-size distribution (DSD) observations that have already been used for a number of applications related to GoAmazon2014/15 science objectives. The first use was the creation of a reflectivity-rain rate (Z-R) relation enabling the calculation of rain rates from the Brazilian Sistema de Protecao da Amazonia (SIPAM) S-band operational radar in Manaus. The radar-derived rainfall is an important constraint for the variational analysis of a large-scale forcing data set, which was recently released for the two IOPs that took place in the 2014 wet and transition seasons, respectively. The SIPAM radar rainfall is also being used to validate a number of cloud-resolving model simulations being run for the campaign. A second use of the Parsivel2 DSDs has been to provide a necessary reference point to calibrate the vertical velocity retrievals from the AMF1 W Band ARM Cloud Radar (WACR) cloud-profiling and ultra-high-frequency (UHF) wind-profiling instruments. Accurate retrievals of in-cloud vertical velocities are important to understand the microphysical and kinematic properties of Amazonian convective clouds and their interaction with the land surface and atmospheric aerosols. Further use of the Parsivel2 DSD observations can be made to better understand precipitation characteristics and their variability during GoAmazon2014/15.

54 ENVIRONMENTAL SCIENCES↗

Savannah River Site Climatology for Research Activities Conducted Onsite and in P-Area (1994-2023)

This report presents a climatology of meteorological variables at the Savannah River Site (SRS) using measurements from the P-Area and Central Climatology meteorological towers to support research activities at the Savannah River Site. Key values included in this report are wind, surface pressure, temperature, relative humidity, soil moisture, cloud fraction, cloud base, lightning, atmospheric stability, and boundary layer parameters. The Central Climatology tower is useful in that it is instrumented at four levels, allowing for an examination of height dependence on some variables.

54 ENVIRONMENTAL SCIENCES↗

Savannah River Site Climatology for Research Activities Conducted Onsite and in P-Area (1994-2023)

Executive Summary This report presents a climatology of meteorological variables at the Savannah River Site (SRS) using measurements from the P-Area and Central Climatology meteorological towers to support research activities at the Savannah River Site. Key values included in this report are wind, surface pressure, temperature, relative humidity, soil moisture, cloud fraction, cloud base, lightning, atmospheric stability, and boundary layer parameters. The Central Climatology tower is useful in that it is instrumented at four levels, allowing for an examination of height dependence on some variables.

54 ENVIRONMENTAL SCIENCES↗

Superconducting Material Growth for Radio-Frequency (RF) Cavities

Superconducting radio-frequency (SRF) cavities, usually manufactured from Niobium (Nb), are vital components of modern particle accelerators because of their ability to achieve high acceleration gradients with little power dissipation. Naturally forming Nb surface oxides significantly alter cavity performance by changing surface resistance. A nondestructive characterization of oxide thickness is helpful for relating surface processing treatments to cavity performance. This work develops a protocol to measure Nb oxide thickness using Angle-Resolved X-ray Photoelectron Spectroscopy (ARXPS) while correcting instrumental errors. Using uniform bulk standard samples (Silver, Aluminum oxide, and Germanium), we determined a baseline correction factor to account for analyzer-related intensity evolution as the measurement angle increases. The correction factor was then applied to Nb 3d ARXPS data. Applying the Strohmeier equation to the corrected data yielded a Nb2O5 thickness of 6.04 nm, closely matching the 5.5 (±.05) nm value obtained from cross-sectional transmission electron microscopy. Our approach will bring a method to incorporate inherent errors in the thickness measurements using ARXPS and can be broadly applied to improve the accuracy of thickness measurements in a wide range of heterostructures.

Lambert, Nathan [Fermilab]↗

Performance of first prototype multi-cell low-surface-field shape cavity

The idea of cavity shaping for higher ultimate acceleration gradients has been proposed for some time, Low Loss/Ichiro and Re-entrant being examples, both seeking a lower Hpk/Eacc at the expense of a higher Epk/Eacc. While experimental verification in single-cell cavities of those shapes was very successful including the record gradient of 59 MV/m, pushing multi-cell cavities of those shapes to higher gradients was prevented by field emission. The Low-Surface-Field (LSF) shape seeks not only a lower Hpk/Eacc but also a lower Epk/Eacc, therefore it has the advantage of raising ultimate gradient at reduced field emission. The first multi-cell LSF shape prototype cavity was built using the standard forming and welding techniques. RF tests have been carried out, following standard ILC TDR baseline surface processing and treatment recipe. Three out of five cells achieved Hpk values corresponding to Eacc 50 MV/m. The current limit is the field emission in end cells. Instrumented testing following end-cell wiping and HPR with larger nozzles is in progress. We will present detailed experimental results and preparation procedures.

Geng, R.-L.↗

Superconducting Material Growth for Radio-Frequency (RF) Cavities

Superconducting radio-frequency (SRF) cavities, usually manufactured from Niobium (Nb), are vital components of modern particle accelerators because of their ability to achieve high acceleration gradients with little power dissipation. Naturally forming Nb surface oxides significantly alter cavity performance by changing surface resistance. A nondestructive characterization of oxide thickness is helpful for relating surface processing treatments to cavity performance. This work develops a protocol to measure Nb oxide thickness using Angle-Resolved X-ray Photoelectron Spectroscopy (ARXPS) while correcting instrumental errors. Using uniform bulk standard samples (Silver, Aluminum oxide, and Germanium), we determined a baseline correction factor to account for analyzer-related intensity evolution as the measurement angle increases. The correction factor was then applied to Nb 3d ARXPS data. Applying the Strohmeier equation to the corrected data yielded a Nb2O5 thickness of 6.04 nm, closely matching the 5.5 (±.05) nm value obtained from cross-sectional transmission electron microscopy. Our approach will bring a method to incorporate inherent errors in the thickness measurements using ARXPS and can be broadly applied to improve the accuracy of thickness measurements in a wide range of heterostructures.

Lambert, Nathan [Fermilab]↗

Development of a new generation of optical slope measuring profiler

A collaboration, including all DOE synchrotron labs, industrial vendors of x-ray optics, and with active participation of the HBZ-BESSY-II optics group has been established to work together on a new slope measuring profiler -- the optical slope measuring system (OSMS). The slope measurement accuracy of the instrument is expected to be<50 nrad for the current and future metrology of x-ray optics for the next generation of light sources. The goals were to solidify a design that meets the needs of mirror specifications and also be affordable; and to create a common specification for fabrication of a multi-functional translation/scanning (MFTS) system for the OSMS. This was accomplished by two collaborative meetings at the ALS (March 26, 2010) and at the APS (May 6, 2010).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Indirect evidence for Levy walks in squeeze film damping

Molecular flow gas damping of mechanical motion in confined geometries, and its associated noise, is important in a variety of fields, including precision measurement, gravitational wave detection, and microelectromechanical systems devices. We used two torsion balance instruments to measure the strength and distance-dependence of 'squeeze film' damping. Measured quality factors derived from free decay of oscillation are consistent with gas particle superdiffusion in Levy walks and inconsistent with those expected from traditional Gaussian random walk particle motion. The distance-dependence of squeeze film damping observed in our experiments is in agreement with a parameter-free Monte Carlo simulation. The squeeze film damping of the motion of a plate suspended a distance d away from a parallel surface scales with a fractional power between d{sup -1} and d{sup -2}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Femtosecond electron deflectometry for measuring transient fields generated by laser-accelerated fast electrons

The temporal evolution of the electric field generated near the surface of a solid target by a femtosecond laser pulse with intensity of 1 x 10{sup 16 }W/cm{sup 2} has been investigated by electron deflectometry; in this technique, ultrashort electron pulses generated by intense femtosecond laser pulses are used as probes. We found that electric field of the order of 10{sup 8 }V/m along the target surface was generated and decayed within 400 fs. The results of this study demonstrate the potential of electron deflectometry for measuring ultrafast phenomena in the femtosecond time domain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coupling a three-dimensional subsurface flow and transport model with a land surface model to simulate stream–aquifer–land interactions (CP v1.0)

Abstract. A fully coupled three-dimensional surface and subsurface land model is developed and applied to a site along the Columbia River to simulate three-way interactions among river water, groundwater, and land surface processes. The model features the coupling of the Community Land Model version 4.5 (CLM4.5) and a massively parallel multiphysics reactive transport model (PFLOTRAN). The coupled model, named CP v1.0, is applied to a 400 m × 400 m study domain instrumented with groundwater monitoring wells along the Columbia River shoreline. CP v1.0 simulations are performed at three spatial resolutions (i.e., 2, 10, and 20 m) over a 5-year period to evaluate the impact of hydroclimatic conditions and spatial resolution on simulated variables. Results show that the coupled model is capable of simulating groundwater–river-water interactions driven by river stage variability along managed river reaches, which are of global significance as a result of over 30 000 dams constructed worldwide during the past half-century. Our numerical experiments suggest that the land-surface energy partitioning is strongly modulated by groundwater–river-water interactions through expanding the periodically inundated fraction of the riparian zone, and enhancing moisture availability in the vadose zone via capillary rise in response to the river stage change. Meanwhile, CLM4.5 fails to capture the key hydrologic process (i.e., groundwater–river-water exchange) at the site, and consequently simulates drastically different water and energy budgets. Furthermore, spatial resolution is found to significantly impact the accuracy of estimated the mass exchange rates at the boundaries of the aquifer, and it becomes critical when surface and subsurface become more tightly coupled with groundwater table within 6 to 7 meters below the surface. Inclusion of lateral subsurface flow influenced both the surface energy budget and subsurface transport processes as a result of river-water intrusion into the subsurface in response to an elevated river stage that increased soil moisture for evapotranspiration and suppressed available energy for sensible heat in the warm season. The coupled model developed in this study can be used for improving mechanistic understanding of ecosystem functioning and biogeochemical cycling along river corridors under historical and future hydroclimatic changes. The dataset presented in this study can also serve as a good benchmarking case for testing other integrated models.

58 GEOSCIENCES↗