Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerating cavity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Design and performance of a new induction furnace for heat treatment of superconducting radiofrequency niobium cavities

Superconducting radio frequency (SRF) cavities made of high purity niobium (Nb) are the building blocks of many modern particle accelerators. The fabrication process includes several cycles of chemical and heat treatment at low ({approx}120 Degree-Sign C) and high ({approx}800 Degree-Sign C) temperatures. In this contribution, we describe the design and performance of an ultra-high-vacuum furnace which uses an induction heating system to heat treat SRF cavities. Cavities are heated by radiation from the Nb susceptor. By using an all-niobium hot zone, contamination of the Nb cavity by foreign elements during heat treatment is minimized and allows avoiding subsequent chemical etching. The furnace was operated up to 1400 Degree-Sign C with a maximum pressure of {approx}1 Multiplication-Sign 10{sup -5} Torr and the maximum achievable temperature is estimated to be higher than 2000 Degree-Sign C. Initial results on the performance of a single cell 1.5 GHz cavity made of ingot Nb heat treated at 1200 Degree-Sign C using this new induction furnace and without subsequent chemical etching showed a reduction of the RF losses by a factor of {approx}2 compared to cavities made of fine-grain Nb which underwent standard chemical and heat treatments.

43 PARTICLE ACCELERATORS↗

Processing and Breakdown Localization Rresults For an L-Band Standing-Wave Cavity

An L-band (1.3 GHz), normal-conducting, 5-cell, standing-wave cavity that was built as a prototype capture accelerator for the ILC is being high-power processed at SLAC. The goal is to demonstrate stable operation at 15 MV/m with 1 msec, 5 Hz pulses and the cavity immersed in a 0.5 Telsa solenoidal magnetic field. This paper summarizes the performance that was ultimately achieved and describes a novel analysis of the modal content of the stored energy in the cavity after a breakdown to determine on which iris it occurred.

43 PARTICLE ACCELERATORS↗

Absorber Materials at Room and Cryogenic Temperatures

We recently reported on investigations of RF absorber materials at cryogenic temperatures conducted at Jefferson Laboratory (JLab). The work was initiated to find a replacement material for the 2 Kelvin low power waveguide Higher Order Mode (HOM) absorbers employed within the original cavity cryomodules of the Continuous Electron Beam Accelerator Facility (CEBAF). This effort eventually led to suitable candidates as reported in this paper. Furthermore, though constrained by small funds for labor and resources, we have analyzed a variety of lossy ceramic materials, several of which could be usable as HOM absorbers for both normal conducting and superconducting RF structures, e.g. as loads in cavity waveguides and beam tubes either at room or cryogenic temperatures and, depending on cooling measures, low to high operational power levels.

43 PARTICLE ACCELERATORS↗

Accelerator Physics Lessons From CBETA, the First Multi-turn SRF ERL

The Cornell-BNL ERL Test Accelerator (CBETA) has been designed, constructed, and commissioned in a collaboration between Cornell and Brookhaven National Laboratory (BNL). It focuses on energy-saving measures in accelerators, including permanent magnets, energy recovery, and superconductors; it has thus been referred to as a green accelerator. CBETA has become the world's first Energy Recovery Linac (ERL) that accelerates through multiple turns and then recovers the energy in superconducting radiofrequency (SRF) cavities though multiple decelerating turns. The energy is then available to accelerate more beam. It has also become the first accelerator that operates 7 beams in the same large-energy aperture Fixed Field Alternating-gradient (FFA) lattice. The FFA is constructed of permanent combined function magnets and transports energies of 42, 78, 114, and 150 MeV simultaneously. Accelerator physics lessons from the commissioning period will be described and applications of such an accelerator from hadron cooling to EUV lithography and from nuclear physics to a compact Compton source will be discussed.

Deitrick, K. E.↗

Overview of the First Five Refurbished CEBAF Cryomodules

The Thomas Jefferson National Accelerator Facility is currently engaged in a cryomodule refurbishment project known as the C50 project. The goal of this project is robust 6 GeV, 5 pass operation of the Continuous Electron Beam Accelerator Facility (CEBAF). The scope of the project includes removing, refurbishing and replacing ten CEBAF cryomodules at a rate of three per year. Refurbishment includes reprocessing of SRF cavities to eliminate field emission and increase the nominal gradient from the original 5 MV/m to 12.5 MV/m. New "dogleg" couplers between the cavity and helium vessel flanges will intercept secondary electrons that produce arcing at the 2 K ceramic window in the fundamental Power Coupler (FPC). Modifications of the external Q (Qext) of the FPC will allow higher gradient operations. Other changes include new ceramic RF windows for the air to vacuum interface of the FPC and improvements to the mechanical tuner. Any damaged or worn components will be repla

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Higher Order Modes Damping Analysis for the SPX Deflecting Cavity Cryomodule

A single-cell superconducting deflecting cavity operating at 2.812 GHz has been proposed and designed for the Short Pulse X-ray (SPX) project for the Advanced Photon Source upgrade. A cryomodule of 4 such cavities will be needed to produce the required 2-MV deflecting voltage. Each deflecting cavity is equipped with one fundamental power coupler (FPC), one lower order mode (LOM) coupler, and two higher order mode (HOM) couplers to achieve the stringent damping requirements for the unwanted modes. The damping of the HOM/LOM modes below the beampipe cutoff has been analyzed in the single cavity geometry and shown to meet the design requirements. The HOMs above beam pipe cutoff in the 4-cavity cyromodule, however, may result in cross coupling which may affect the HOM damping and potentially trapped modes between the cavities which could produce RF heating to the beamline bellows and even be detrimental to the beam. We have evaluated the HOM damping and trapped modes in the 4-cavity cryomodule using the parallel finite element EM code ACE3P developed at SLAC. We will present the results of the cryomodule analysis in this paper.

43 PARTICLE ACCELERATORS↗

Elucidating ion capture and transport mechanisms of Preyssler anions in aqueous solutions using biased MACE-accelerated MD simulations

Equilibrium and biased multi-atomic cluster expansion (MACE) accelerated molecular dynamics (MD) simulations in aqueous solutions are performed to investigate the ion capture and transport mechanisms of the {P 5 W 30 } Preyssler anion (PA) as the smallest representative member of the extended polyoxometalate (POM) family with an internal cavity. The unique interatomic interactions present in the internal cavity vs the exterior of PA are carefully investigated using equilibrium MACE MD simulations for two representative Na(H 2 O)@PA and Na@PA complexes in aqueous solutions. Our careful analyses of radial distribution functions and coordination numbers show that the presence of confined water in Na(H 2 O)@PA has profound modulating effects on the nature of the interactions of the encapsulated ion with the oxygens of the PA cavity. Using well-converged MACE-accelerated multiple walker well-tempered metadynamics simulations with nanosecond timescales, two different associative (ion exchange) and dissociative (ion ejection) ion transport mechanisms were carefully investigated for Na + as one of the most abundant and representative ions present in seawater and saline solutions. By comparing systems with and without confined water, it was found that the presence of only one pre-encapsulated confined water in Na(H 2 O)@PA dramatically changes the free energy landscape of ion transport processes. It was also found that the contraction and dilation of the two windows present in PA directly influence the Na + and H 2 O transport. Furthermore, the results from this work are helpful, as they show a viable path toward tuning the ion exchange and transport phenomena in aqueous solutions of POM molecular clusters and frameworks.

25 ENERGY STORAGE↗

Summary Report for the C50 Cryomodule Project

The Thomas Jefferson National Accelerator Facility has recently completed the C50 cryomodule refurbishment project. The goal of this project was to enable robust 6 GeV, 5 pass operation of the Continuous Electron Beam Accelerator Facility (CEBAF). The scope of the project included removal, refurbishment and reinstallation of ten CEBAF cryomodules at a rate of three per year. The refurbishment process included reprocessing of SRF cavities to eliminate field emission and to increase the nominal gradient from the original 5 MV/m to 12.5 MV/m. New 'dogleg' couplers were installed between the cavity and helium vessel flanges to intercept secondary electrons that produce arcing in the fundamental Power Coupler (FPC). Other changes included new ceramic RF windows for the air to vacuum interface of the FPC and improvements to the mechanical tuner. Damaged or worn components were replaced as well. All ten of the refurbished cryomodules are now installed in CEBAF and are currently operational. This paper will summarize the performance of the cryomodules.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Magnet design for the splitter/combiner regions of CBETA, the Cornell-Brookhaven Energy-Recovery-Linac Test Accelerator

The Cornell-Brookhaven Energy-Recovery-Linac Test Accelerator (CBETA) will provide a 150-MeV electron beam using four acceleration and four deceleration passes through the Cornell Main Linac Cryomodule housing six 1.3-GHz superconducting RF cavities. The return path of this 76-m-circumference accelerator will be provided by 106 fixed-field alternating-gradient (FFAG) cells which carry the four beams of 42, 78, 114 and 150 MeV. Here we describe magnet designs for the splitter and combiner regions which serve to match the on-axis linac beam to the off-axis beams in the FFAG cells, providing the path-length adjustment necessary to energy recovery for each of the four beams. The path lengths of the four beamlines in each of the splitter and combiner regions are designed to be adapted to 1-, 2-, 3-, and 4-pass staged operations. Design specifi- cations and modeling for the 24 dipole and 32 quadrupole electromagnets in each region are presented. The CBETA project will serve as the first demonstration of multi-pass energy recovery using superconducting RF cavities with FFAG cell optics for the return loop.

43 PARTICLE ACCELERATORS↗

Design for a Muon Front End with Magnetically Shielded RF Cavities

In the baseline Neutrino Factory muon front end, strong, closely spaced solenoid magnets are used to contain the high emittance muon beam. In addition, significant acceleration is required for bunching, phase rotation and cooling, requiring RF cavities operating near to their maximum achievable gradient. There are experimental indications that RF cavities may not be able to achieve these large gradients in the presence of such intense magnetic fields. In this paper, I discuss the design of a muon cooling channel that is designed with RF cavities removed from the intense magnetic fields, and examine the change in performance that results from this compromise.

43 PARTICLE ACCELERATORS↗

Deformation and Fracture Behavior of Additively Manufactured 316L Stainless Steel

Tensile deformation and fracture behavior of an additively manufactured (AM) 316L stainless steel (SS) in the as-built, stress-relieved, and solution-annealed conditions was investigated using in situ tensile testing in a scanning electron microscope with an electron back scattering diffraction (SEM–EBSD) detector. Analyses were performed to discuss the characteristic deformation and fracture process of the fine-grained AM 316L SS with and without relaxation heat treatment. The as-built 316L showed the highest strength, and both post-build heat treatments lowered the strength of the alloy. Regardless of the post-build processing, the AM 316L SS showed overall higher strength but slightly lower ductility when compared to the wrought (WT) 316L SS. Analysis of EBSD data indicated that the characteristic microstructural features from AM, such as the complex and fine grain morphology, dislocation network, pores, and silicon-rich oxides, evolved and exerted various roles during the tensile deformation and fracture processes. Further, it was obvious that the interaction of dislocation slips with oxide particles and cavities (or pores) resulted in an accelerated cracking in AM 316L SS. Overall, however, their influence on mechanical behavior was limited, as the genuinely high ductility of 316L SS could help avoid any premature or brittle fracture.

36 MATERIALS SCIENCE↗

Similarity criteria in calculations of the energy characteristics of a cw oxygen - iodine laser

The calculated and experimental data on the energy efficiency of a cw oxygen - iodine laser (OIL) are analysed based on two similarity criteria, namely, on the ratio of the residence time of the gas mixture in the resonator to the characteristic time of extraction of the energy stored in singlet oxygen td and on the gain-to-loss ratio {Pi}. It is shown that the simplified two-level laser model satisfactorily predicts the output characteristics of OILs with a stable resonator at {tau}{sub d} {<=} 7. Efficient energy extraction from the OIL active medium is achieved in the case of {tau}{sub d} = 5 - 7, {Pi} = 4 - 8. (lasers)

43 PARTICLE ACCELERATORS↗

Breakdown in ceramic window

A capacitive type coaxial ceramic window is designed for the SC linac. The coaxial power coupler has inner conductor diameter 34.8 mm and outer conductor diameter 80 mm. An alumina disk of diameter 150 mm and thickness 3.6 mm is used as ceramic. The diameter of the inner conductor of the coupler near the ceramic is increased to 39.2 mm to match the impedance at 1050 MHz. A copper prototype of the window is fabricated and characterized. A performance of the window is often degraded because of the multipacting. A CST particle studio is used to simulate the multipacting trajectories. The particle trajectories are observed at different locations and different power levels up to 1 MW. The results are dependent on the initial position of the primary electron and power level. A few soft multipacting barriers are observed at the operating power level. (author)

43 PARTICLE ACCELERATORS↗

In vivo measurement of bone aluminum in population living in southern Ontario, Canada

The harmful biological effect of excessive aluminum (Al) load in humans has been well documented in the literature. Al stored in bone, for instance due to dialysis treatment or occupational exposure, can interfere with normal bone remodeling leading to osteodystrophy, osteoarthritis, or osteomalacia. On the other hand, the relationship between chronic Al exposure and the risk of Alzheimer's disease remains controversial. In this work, the feasibility of in vivo neutron activation analysis (IVNAA) for measuring Al levels in the human hand bone, using the thermal neutron capture reaction {sup 27}Al(n,{gamma}){sup 28}Al, is reported. This noninvasive diagnostic technique employs a high beam current Tandetron accelerator based neutron source, an irradiation/shielding cavity, a 4{pi} NaI(Tl) detector system, and a new set of hand bone phantoms. The photon spectra of the irradiated phantom closely resemble those collected from the hands of nonexposed healthy subjects. A protocol was developed using the newly developed hand phantoms, which resulted in a minimum detectable limit (MDL) of 0.29 mg Al in the human hand. Using the ratio of Al to Ca as an index of Al levels per unit bone mass, the MDL was determined as 19.5{+-}1.5 {mu}g Al/g Ca, which is within the range of the measured levels of 20-27 {mu}g Al/g Ca[ICRP, Report of the Task Group on Reference Man, Publication 23 (Pergamon, Oxford, 1975)] found in other in vivo and in vitro studies. Following the feasibility studies conducted with phantoms, the diagnostic technique was used to measure Al levels in the hand bones of 20 healthy human subjects. The mean hand bone Al concentration was determined as 27.1{+-}16.1 ({+-}1 SD) {mu}g Al/g Ca. The average standard error (1{sigma}) in the Al/Ca is 14.0 {mu}g Al/g Ca, which corresponds to an average relative error of 50% in the measured levels of Al/Ca. These results were achieved with a dose equivalent of 17.6 mSv to a hand and an effective dose of 14.4 {mu}Sv. This effective dose is approximately half of that received in a chest radiograph examination. It is recommended to investigate the use of the bone Al IVNAA diagnostic technique for in vivo measurements of patients with documented overload of Al in bone.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

20-24 GeV FFA CEBAF Energy Upgrade

A proposal was formulated to increase the CEBAF energy from the present 12 GeV to 20-24 GeV by replacing the highest-energy arcs with Fixed Field Alternating Gradient (FFA) arcs. The new pair of arcs would provide six or seven new beam passes, going through this magnet array, allowing the energy to be nearly doubled using the existing CEBAF SRF cavity system. One of the immediate accelerator design tasks is to develop a proof-of-principle FFA arc magnet lattice that would support simultaneous transport of 6-7 passes with energies spanning a factor of two. We also examine the possibility of using combined function magnets to configure a cascade, six-way beam split switchyard. Finally, a novel multi-pass linac optics based on a weakly focusing lattice is being explored.

Bogacz, Slawomir Alex↗

Stagger Tuning Summary [Slides]

Beam Breakup (BBU) is dangerous for high-current linear induction accelerators (LIA) used for flash radiography. Cavity mode RF is coupled to the beam. For frequencies lower than the beam-pipe cutoff, the cavities only communicate via RF on the beam. This cumulative mode BBU grows exponentially with a number of e-foldings proportional to (Number of cavities) X (Beam current) X (Coupling factor) / (Magnetic focusing field).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CEBAF FFA Energy Upgrade

Encouraged by recent success of CBETA, a proposal was formulated to increase the CEBAF energy from the present 12 GeV to 20-24 GeV by replacing the highest-energy arcs with Fixed Field Alternating Gradient (FFA) arcs. The new pair of arcs would provide six or seven new beam passes, going through this magnet array, allowing the energy to be nearly doubled using the existing CEBAF SRF cavity system. One of the immediate accelerator design tasks is to develop a proof-of-principle FFA arc magnet lattice that would support simultaneous transport of 6-7 passes, with energies spanning a factor of two. We also examine a possibility of using combined function magnets to configure a cascade, six-way beam split switchyard. Finally, a novel, multi-pass linac optics based on a triplet focusing lattice is being explored.

Bogacz, S.↗

A new component of cosmic rays of unknown origin at a few MeV per nucleon

Recently discovered anomalies in the abundances and energy spectra of quiet time, extraterrestrial hydrogen, helium, carbon, nitrogen, and oxygen require serious revisions of origin theories to account for this new component of cosmic radiation. Abnormally large O/C and N/C ratios, long term intensity variations with time, and radial gradient measurements indicate a non-solar origin for these 2 to 30 MeV/nucleon particles. Ideas suggested to explain these measurements range from acceleration of galactic source material having an unusual composition to local acceleration of particles within the solar cavity. Observations are at present insufficient to choose between these alternate origin models.

Gloecker, G.↗