Search NASA⌕ Search

SEARCH · Search NASA

Results for “BACKSCATTERING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Exploring the potential of using L-Band InSAR for the mapping of flooded vegetation in tropical wetlands

Wetlands play a critical role in global water and carbon cycles, yet monitoring their water extent remains difficult, particularly beneath dense vegetation. SAR-based techniques such as backscatter thresholding are limited by complex scattering mechanisms, while fully polarimetric SAR (PolSAR) data capable of detecting doublebounce scattering remain scarce. To address these challenges, this study evaluates the potential of Interferometric SAR (InSAR) for mapping water surfaces beneath vegetation, termed flooded vegetation, using the Atrato floodplain in Colombia as a case study. We develop an automated workflow combining InSAR fringe detection with local phase homogeneity analysis and random sampling of processing parameters to generate probabilistic flooded vegetation maps. Applied to ALOS PALSAR-1 L-band image pairs from 2007–2011, the workflow captures seasonal fluctuations in flooded extent ranging from 500 to 1,500 km2. Compared to other L-band SAR inundation products, the InSAR-based maps identify broader flooded areas, with ~70% agreement in pairwise comparisons. Around 84% of detections align with existing wetland inventories and seasonal changes correspond with regional hydrological indicators, including terrestrial water storage anomalies and water gauge measurements. PolSAR analysis shows that InSAR complements backscatter-based methods by detecting inundation in areas with weak double-bounce signals. These findings suggest that combining InSAR with backscatter-based methods can improve detection of flooded vegetation, which is especially relevant for the upcoming NISAR mission that will offer frequent global L-band observations.

Coastal inundation↗

Optimizing detector geometry for trace element mapping by X-ray fluorescence

Trace metals play critical roles in a variety of systems, ranging from cells to photovoltaics. X-Ray Fluorescence (XRF) microscopy using X-ray excitation provides one of the highest sensitivities available for imaging the distribution of trace metals at sub-100 nm resolution. With the growing availability and increasing performance of synchrotron light source based instruments and X-ray nanofocusing optics, and with improvements in energy-dispersive XRF detectors, what are the factors that limit trace element detectability? To address this question, we describe an analytical model for the total signal incident on XRF detectors with various geometries, including the spectral response of energy dispersive detectors. This model agrees well with experimentally recorded X-ray fluorescence spectra, and involves much shorter calculation times than with Monte Carlo simulations. With such a model, one can estimate the signal when a trace element is illuminated with an X-ray beam, and when just the surrounding non-fluorescent material is illuminated. From this signal difference, a contrast parameter can be calculated and this can in turn be used to calculate the signal-to-noise ratio (S/N) for detecting a certain elemental concentration. We apply this model to the detection of trace amounts of zinc in biological materials, and to the detection of small quantities of arsenic in semiconductors. We conclude that increased detector collection solid angle is (nearly) always advantageous even when considering the scattered signal. However, given the choice between a smaller detector at 90° to the beam versus a larger detector at 180° (in a backscatter-like geometry), the 90° detector is better for trace element detection in thick samples, while the larger detector in 180° geometry is better suited to trace element detection in thin samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase Transition of H 2 in Subnanometer Pores Observed at 75 K

In this paper, we report a phase transition in H 2 adsorbed in a locally graphitic Saran carbon with subnanometer pores 0.5–0.65 nm in width, in which two layers of hydrogen can just barely squeeze, provided they pack tightly. The phase transition is observed at 75 K, temperatures far higher than other systems in which an adsorbent is known to increase phase transition temperatures: for instance, H 2 melts at 14 K in the bulk, but at 20 K on graphite because the solid H 2 is stabilized by the surface structure. Here we observe a transition at 75 K and 77–200 bar: from a low-temperature, low-density phase to a high-temperature, higher density phase. We model the low-density phase as a monolayer commensurate solid composed mostly of para-H 2 (the ground nuclear spin state, S = 0) and the high-density phase as an orientationally ordered bilayer commensurate solid composed mostly of ortho-H 2 (S = 1). We attribute the increase in density with temperature to the fact that the oblong ortho-H 2 can pack more densely. The transition is observed using two experiments. The high-density phase is associated with an increase in neutron backscatter by a factor of 7.0 ± 0.1. Normally, hydrogen produces no backscatter (scattering angle >90°). This backscatter appears along with a discontinuous increase in the excitation mass from 1.2 amu to 21.0 ± 2.3 amu, which we associate with collective nuclear spin excitations in the orientationally ordered phase. Film densities were measured using hydrogen adsorption. Finally, no phase transition was observed in H 2 adsorbed in control activated carbon materials.

36 MATERIALS SCIENCE↗

Interpretable ensemble learning unveils main aerosol optical properties in predicting cloud condensation nuclei number concentration

Variations in cloud condensation nuclei number concentration (N CCN ) significantly influence cloud microphysics, yet direct N CCN measurements remain challenging. Here, we present an N CCN ensemble learning (NEL) model utilizing ensemble learning and interpretability analysis on aerosol optical parameters. Validated at two land sites, two ocean sites and one polar site within the Atmospheric Radiation Measurement program, the mean absolute percentage error range of the NEL model across different environments is from 12% to 36%, demonstrating high accuracy. Key findings reveal that aerosol optical parameters can serve as predictors for N CCN . Aerosol scattering and backscattering coefficients, absorption coefficient, backscatter fraction (BSF), and Ångström exponent (AE) are positively correlated with N CCN , while single scattering albedo shows negative correlations. N CCN prediction at land sites is highly sensitive to BSF, largely driven by the backscattering coefficient, as fine particles dominate in these sites. At ocean sites, N CCN prediction is more sensitive to AE, primarily influenced by the scattering coefficient, due to the higher proportion of larger particles. At the polar site, N CCN prediction shows sensitivity to both BSF and AE, mainly driven by the scattering coefficient, as polar sites are cleaner and contain larger particles. These differences reflect the variation in particle size and number concentration across different environments.

Atmospheric science↗

Vlasov simulation of Langmuir decay instability

A parametric decay process of beam-generated Langmuir waves is examined by a one-dimensional Vlasov code simulation in the open system. It is confirmed that pump Langmuir waves decay into backscattered Langmuir and ion acoustic waves when the wave energy is higher than the thermal energy of background electrons. In the present Vlasov simulation, a large-amplitude pump Langmuir wave is excited by an electron beam. Then a backscattered Langmuir wave and a forward ion acoustic wave are excited by the parametric decay instability. When the wave energy of the backscattered Langmuir waves is also higher than the thermal energy of background electrons, backward ion acoustic waves are also excited. As a result, the wavenumber spectra of Langmuir and ion acoustic waves are broadened in both forward and backward directions, suggesting possible multiple parametric decay processes of Langmuir waves in a beam-plasma system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comment on 'Stimulated Raman scattering of laser from periodically spaced nanoparticles' [Phys. Plasmas 16, 093106 (2009)]

Parashar [Phys. Plasmas 16, 093106 (2009)] studied the Raman backscattering of electromagnetic waves from nanoparticle lattice. We have demonstrated that the uncoupled dispersion curves have incorrect cutoff frequencies and the electromagnetic dispersion curves do not have correct asymptotic behavior at large frequencies. It has been shown that Parashar obtained an incorrect diagram of the growth rate for which the pump wave frequency goes below the cutoff frequency of the electromagnetic wave. Correct diagrams for the Raman backscattering as well as forward scattering are presented. It has been shown that backscattering has a larger maximum growth rate. We also found no instability if scattered radiation belongs to the lower branch of the dispersion curves.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Surpassing one x-ray photon per electron in nonlinear Thomson scattering in 180 deg. geometry

We have obtained the general analytical expressions of harmonic radiation for Thomson scattering (TS) of arbitrary polarized laser by virtue of generalized Bessel functions and derived the extremum conditions for backscattered harmonics. Especially, for the fundamental backscattered Thomson scattering x-ray yield, we have shown that at the same conditions, the circular polarization reaches maximum while the linear case minimum. This effect is significant when a{sup 2}{>=}1. With the assumption that the x-ray photon yield of a realistic focused pulse of energy E, wavelength {lambda}, and Rayleigh range z{sub R} is equivalent to a plane wave pulse containing N{sub l} cycles via the relation N{sub l}{lambda}=pz{sub R} where the effective factor p is of order one, we applied the plane wave results to realistic laser pulses and deduced that the backscattered x-ray photon number N{sub f} per electron achieves its peak value when the average dimensionless laser intensity a{sup 2}=0.677 and is irrelevant to the value of p. Since N{sub f} and its maximum N{sub fmax} both scale with the square root of E/{lambda}, it is realizable to attain N{sub f}{>=}1 using joule-scale laser pulses while a great challenge for N{sub f}>10.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance of beryllium targets with full-scale capsules in low-fill 6.72-mm hohlraums on the National Ignition Facility

When used with 1.06-mm beryllium (Be) capsules on the National Ignition Facility, gold hohlraums with the inner diameter of 5.75 mm and helium gas fill density of 1.6 mg/cm 3 exhibit significant drive degradation due to laser energy backscatter (of order 14%–17%) and “missing” X-ray drive energy (about 32% during the main pulse). Also, hard to simulate cross-beam energy transfer (CBET) must be used to control the implosion symmetry. Larger, 6.72-mm hohlraums with fill densities ≤0.6 mg/cm 3 generally offer improved drive efficiency, reduced hot-electron preheat, and better control of the implosion symmetry without CBET. Recently, we carried out an exploratory campaign to evaluate performance of 1.06-mm Be capsules in such hohlraums and determine optimal hohlraum parameters. Specifically, we performed in this paper a hohlraum fill-density scan with a three-shock, 9.5-ns laser pulse and found that an appropriate axial laser repointing and azimuthal outer-quad splitting resulted in significantly improved hohlraum energetics at fill densities ≤0.3 mg/cm 3 (with backscattered and “missing” energies being of about 5% and 23% of the total laser energy, respectively). The capsule shape at stagnation was slightly oblate and improved with lowering the fill density. We also performed an implosion with a lower-picket, 12.6-ns pulse at the hohlraum fill density of 0.15 mg/cm 3 to observe comparable hohlraum energetics (about 3% of backscattered and 27% of “missing” energy) but an even more oblate implosion shape. Finally, achieving symmetric implosions of 1.06-mm Be capsules in low-fill, 6.72-mm gold hohlraums with reasonably low-adiabat pulses may not be feasible. However, symmetric implosions have recently been successfully demonstrated in such hohlraums with 0.8-mm Be capsules.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Application of cross-beam energy transfer to control drive symmetry in ICF implosions in low gas fill Hohlraums at the National Ignition Facility

Cross beam energy transfer (CBET), invoked by setting a wavelength difference, Δλ, between inner and outer beam cones, can be used to increase the drive on the waist in indirectly driven inertial confinement fusion experiments at the National Ignition Facility (NIF). Historically, hot spot symmetry control in capsule implosions in high (≥0.9 mg/cm 3 4 He) gas fill Hohlraums was enabled by substantial CBET. However, these implosion designs suffered from inflight symmetry swings, high SRS backscatter on the inner cones, and significant hot electron generation posing a threat to DT fuel preheat. Subsequent experiments in larger, low (≤0.6 mg/cm 3 4 He) gas fill Hohlraums demonstrated round implosions by varying the inner cone fraction throughout the laser drive at Δλ = 0 Å while keeping backscatter and hot electron generation very low. To enable driving larger capsules at a given Hohlraum size, additional tools for implosion symmetry control are required. With this goal in mind, here we present a detailed experimental study of using CBET in low gas fill Hohlraums near NIF's current peak power capability. We find a ~2.5× higher sensitivity of the P 2 Legendre mode with respect to Δλ changes compared to that of high gas fill designs. We attribute this observation to the fact that backscatter remains very low and that CBET remains in a linear regime, as suggested by simulations. As a result, a much smaller Δλ of order 1 Å is sufficient for sustaining implosion symmetry while keeping laser-to- Hohlraum coupling high and hot electron generation very low. While this study used plastic ablator capsules, our findings can be generalized to other ablator materials and, hence, show great promise for using wavelength detuning as a strong lever for implosion symmetry control in future low gas fill designs that require smaller case to capsule ratios in order to increase the energy coupled to the capsule.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Raman gap and collisional absorption

One of the long-standing puzzles observed in many laser-plasma experiments is the gap in the Raman backscattering spectrum. This gap is characterized by the absence of backscattered light between some critical wavelength and twice the incident laser wavelength. The latter is associated with the absolute Raman instability from the quarter-critical density surface. Supported by particle-in-cell (PIC) simulations, it is suggested that the gap can result from the collisional damping of the backscattered light. A linear analysis of the competition between the Raman growth rate and the damping rate in a non-homogenous plasma predicts the gap's existence and width as a function of the system's parameters. The theory is compared with the PIC simulations and past experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interpreting scattered neutron spectra on omega cryogenic implosions with measured backgrounds and higher-order scattering

Measurements of the areal density (⁠ρR⁠) of inertially confined implosions are critical to evaluate their performance. On OMEGA, ρR is inferred from measurements of the scattered neutron spectrum via neutron-time-of-flight (nTOF) and magnetic recoil spectrometer detectors. The nTOF measurements, in particular, have the ability to measure a wide range of neutron energies and thus scattering angles, with high precision. However, the neutrons that are backscattered into the detector must transit through the entire dense fuel assembly, and as a result are subject to rescattering effects, which have been heretofore neglected in the interpretation of OMEGA neutron spectra. At the backscatter edge, neglecting rescattering on OMEGA can lead to a ~10 to 20% reduction of the apparent areal density and therefore must be included in the analysis. The low ρR s on OMEGA also mean that backgrounds from non-target physics effects, such as scattering in the target chamber or slow scintillator decays, can significantly alter the measured signal. Here, we discuss how the Monte Carlo neutron spectrum postprocessor IRIS is used to include second-order scattering effects in the interpretation of the scattered neutron spectrum in OMEGA implosion experiments, and how dedicated implosion experiments are used to measure nTOF backgrounds in order to infer backscattered areal densities on OMEGA.

Deuterium↗

Quantitative investigation of surface structure and interatomic potential with impact-collision ion scattering spectroscopy

Helium ion beam interactions with materials have important implications for magnetic confinement fusion, material modification, and helium ion microscopy. These interactions depend on the precise physics of how helium ions channel into the materials, which can vary greatly based on the local crystalline orientation. Here, we performed a dedicated experiment to investigate helium ion channeling in a well-characterized tungsten single crystal. Time-of-flight impact-collision ion scattering spectroscopy was used to obtain multi-angle maps of the backscattering intensity for 3 keV He + → W(111). We found that the backscattering intensity profile arising from helium ion channeling could be well described by a shadow cone analysis. This analysis revealed that subsurface W atoms as deep as the ninth monolayer contributed to the backscattering intensity profile. Binary collision approximation simulations were performed with MARLOWE to model the experimental maps with sufficient accuracy to allow for quantitative comparisons using reliability factors. These quantitative comparisons were applied to investigate how the W lattice structure and He–W interatomic potential affect the multi-angle maps.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Remote detection of radioactive material using a short-pulse CO 2 laser

Detection of radioactive material at distances greater than the radiated particle range is an important goal with applications in areas such as national defense and disaster response. Here, we demonstrate avalanche-breakdown-based remote detection of a 3.6 mCi α-particle source at a standoff distance of 10 m, using 70 ps, long-wave infrared (λ = 9.2 µm) CO 2 laser pulses. This is ∼10 times longer than our previous results using a mid-IR laser. The primary detection method is direct backscatter from microplasmas generated in the laser focal volume. The backscatter signal is amplified as it propagates back through the CO 2 laser chain, enhancing sensitivity by >100 times. Here we also characterize breakdown plasmas with fluorescence imaging, and present a simple model to estimate backscattered signals as a function of the seed density profile in the laser focal volume. All of this is achieved with a relatively long-drive laser focal geometry (f/200) that is readily scalable to >100 m.

43 PARTICLE ACCELERATORS↗

Pushing the Limits of Plasma Length in Inertial-Fusion Laser-Plasma Interaction Experiments

We demonstrate laser beam propagation and low backscatter in laser produced hohlraum plasmas of ignition plasma length. At intensities I<5x10{sup 14} W cm{sup -2} greater than 80% of the energy in a blue (3{omega}, 351 nm) laser is transmitted through a L=5-mm long, high-temperature (T{sub e}=2.5 keV), high-density (n{sub e}=5x10{sup 20} cm{sup -3}) plasma. These experiments show that the backscatter scales exponentially with plasma length which is consistent with linear theory. The backscatter calculated by a new steady state 3D laser-plasma interaction code developed for large ignition plasmas is in good agreement with the measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Comparison of Different NDE Signal Processing Techniques Based on Waveform Entropies Applied to Long Fiber Graphite/Epoxy Plates

This study compares different approaches for imaging the internal architecture of graphite/epoxy composites using backscattered ultrasound. Two cases are studied. In the first, near-surface defects in a thin graphite/epoxy plates are imaged. The same backscattered waveforms were used to produce peak-to-peak, logarithm of signal energy, as well as entropy images of different types. All of the entropy images exhibit better border delineation and defect contrast than the either peak-to-peak or logarithm of signal energy. The best results are obtained using the joint entropy of the backscattered waveforms with a reference function. Two different references are examined. The first is a reflection of the insonifying pulse from a stainless steel reflector. The second is an approximate optimum obtained from an iterative parametric search. The joint entropy images produced using this reference exhibit three times the contrast obtained in previous studies. These plates were later destructively analyzed to determine size and location of near-surface defects and the results found to agree with the defect location and shape as indicated by the entropy images. In the second study, images of long carbon graphite fibers (50% by weight) in polypropylene thermoplastic are obtained as a first step toward ultrasonic determination of the distributions of fiber position and orientation.

Entropy Imaging↗

Monte Carlo investigation of breast intraoperative radiation therapy with metal attenuator plates

In intraoperative electron radiation therapy for breast cancer, attenuation plates are commonly used to protect organs at risk. These plates can be made of different materials, and the correct material (or combination of materials) has to be chosen in order to achieve the desired attenuation, while avoiding excessive backscattered radiation. The Monte Carlo method (BEAMnrcMP and DOSXYZnrcMP) has been used to characterize the electron beam generated by the setup (composed of a nondedicated linac and an applicator), and to simulate the percent depth dose (PDD) for plates of different materials. The beam has been characterized for nominal energies of 9 and 12 MeV. Several differently composed plates have been investigated: it was found, as expected, that the use of a plate presenting to the electron beam a high-Z material (i.e., lead) has to be avoided because of excessive backscatter (up to 52% compared to the PDD without plate). On the other hand, the use of a single low-Z material (i.e., aluminum) in the plate can lead to an insufficient attenuation of the beam. The two-layer plate (6 mm of Al plus 3 mm of Cu) used in S. Chiara Hospital has been found to attenuate the beam almost completely for both considered energies, causing negligible backscatter radiation. The spectrum at various depth and at the tissue-plate interface has also been investigated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of TG-43 and TG-186 in breast irradiation using a low energy electronic brachytherapy source

Purpose: The recently updated guidelines for dosimetry in brachytherapy in TG-186 have recommended the use of model-based dosimetry calculations as a replacement for TG-43. TG-186 highlights shortcomings in the water-based approach in TG-43, particularly for low energy brachytherapy sources. The Xoft Axxent is a low energy (<50 kV) brachytherapy system used in accelerated partial breast irradiation (APBI). Breast tissue is a heterogeneous tissue in terms of density and composition. Dosimetric calculations of seven APBI patients treated with Axxent were made using a model-based Monte Carlo platform for a number of tissue models and dose reporting methods and compared to TG-43 based plans. Methods: A model of the Axxent source, the S700, was created and validated against experimental data. CT scans of the patients were used to create realistic multi-tissue/heterogeneous models with breast tissue segmented using a published technique. Alternative water models were used to isolate the influence of tissue heterogeneity and backscatter on the dose distribution. Dose calculations were performed using Geant4 according to the original treatment parameters. The effect of the Axxent balloon applicator used in APBI which could not be modeled in the CT-based model, was modeled using a novel technique that utilizes CAD-based geometries. These techniques were validated experimentally. Results were calculated using two dose reporting methods, dose to water (D{sub w,m}) and dose to medium (D{sub m,m}), for the heterogeneous simulations. All results were compared against TG-43-based dose distributions and evaluated using dose ratio maps and DVH metrics. Changes in skin and PTV dose were highlighted. Results: All simulated heterogeneous models showed a reduced dose to the DVH metrics that is dependent on the method of dose reporting and patient geometry. Based on a prescription dose of 34 Gy, the average D{sub 90} to PTV was reduced by between ∼4% and ∼40%, depending on the scoring method, compared to the TG-43 result. Peak skin dose is also reduced by 10%–15% due to the absence of backscatter not accounted for in TG-43. The balloon applicator also contributed to the reduced dose. Other ROIs showed a difference depending on the method of dose reporting. Conclusions: TG-186-based calculations produce results that are different from TG-43 for the Axxent source. The differences depend strongly on the method of dose reporting. This study highlights the importance of backscatter to peak skin dose. Tissue heterogeneities, applicator, and patient geometries demonstrate the need for a more robust dose calculation method for low energy brachytherapy sources.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-439: An Improved Formula of Scatter-To-Primary Ratio for Photon Dose Calculation

Purpose: Scatter-to-primary ratio (SPR) is an important dosimetric quantity that describes the contribution from the scatter photons in an external photon beam. The purpose of this study is to develop an improved analytical formula to describe SPR as a function of circular field size (r) and depth (d) using Monte Carlo (MC) simulation. Methods: MC simulation was performed for Mohan photon spectra (Co-60, 4, 6, 10, 15, 23 MV) using EGSNRC code. Point-spread scatter dose kernels in water are generated. The scatter-to-primary ratio (SPR) is also calculated using MC simulation as a function of field size for circular field size with radius r and depth d. The doses from forward scatter and backscatter photons are calculated using a convolution of the point-spread scatter dose kernel and by accounting for scatter photons contributing to dose before (z' d) reaching the depth of interest, d, where z' is the location of scatter photons, respectively. The depth dependence of the ratio of the forward scatter and backscatter doses is determined as a function of depth and field size. Results: We are able to improve the existing 3-parameter (a, w, d0) empirical formula for SPR by introducing depth dependence for one of the parameter d0, which becomes 0 for deeper depths. The depth dependence of d0 can be directly calculated as a ratio of backscatter-to-forward scatter doses for otherwise the same field and depth. With the improved empirical formula, we can fit SPR for all megavoltage photon beams to within 2%. Existing 3-parameter formula cannot fit SPR data for Co-60 to better than 3.1%. Conclusion: An improved empirical formula is developed to fit SPR for all megavoltage photon energies to within 2%.

60 APPLIED LIFE SCIENCES↗