Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cancer models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Liposomal formulation of {alpha}-tocopheryl maleamide: In vitro and in vivo toxicological profile and anticancer effect against spontaneous breast carcinomas in mice

The vitamin E analogue {alpha}-tocopheryl succinate ({alpha}-TOS) is an efficient anti-cancer drug. Improved efficacy was achieved through the synthesis of {alpha}-tocopheryl maleamide ({alpha}-TAM), an esterase-resistant analogue of {alpha}-tocopheryl maleate. In vitro tests demonstrated significantly higher cytotoxicity of {alpha}-TAM towards cancer cells (MCF-7, B16F10) compared to {alpha}-TOS and other analogues prone to esterase-catalyzed hydrolysis. However, in vitro models demonstrated that {alpha}-TAM was cytotoxic to non-malignant cells (e.g. lymphocytes and bone marrow progenitors). Thus we developed lyophilized liposomal formulations of both {alpha}-TOS and {alpha}-TAM to solve the problem with cytotoxicity of free {alpha}-TAM (neurotoxicity and anaphylaxis), as well as the low solubility of both drugs. Remarkably, neither acute toxicity nor immunotoxicity implicated by in vitro tests was detected in vivo after application of liposomal {alpha}-TAM, which significantly reduced the growth of cancer cells in hollow fiber implants. Moreover, liposomal formulation of {alpha}-TAM and {alpha}-TOS each prevented the growth of tumours in transgenic FVB/N c-neu mice bearing spontaneous breast carcinomas. Liposomal formulation of {alpha}-TAM demonstrated anti-cancer activity at levels 10-fold lower than those of {alpha}-TOS. Thus, the liposomal formulation of {alpha}-TAM preserved its strong anti-cancer efficacy while eliminating the in vivo toxicity found of the free drug applied in DMSO. Liposome-based targeted delivery systems for analogues of vitamin E are of interest for further development of efficient and safe drug formulations for clinical trials.

60 APPLIED LIFE SCIENCES↗

Use of microgravity bioreactors for development of an in vitro rat salivary gland cell culture model

During development, salivary gland (SG) cells both secrete factors which modulate cellular behavior and express specific hormone receptors. Whether SG cell growth is modulated by an autocrine epidermal growth factor (EGF) receptor-mediated signal transduction pathway is not clearly understood. SG tissue is the synthesis site for functionally distinct products including growth factors, digestive enzymes, and homeostasis maintaining factors. Historically, SG cells have proven difficult to grow and may be only maintained as limited three-dimensional ductal-type structures in collagen gels or on reconstituted basement membrane gels. A novel approach to establishing primary rat SG cultures is use of microgravity bioreactors originally designed by NASA as low-shear culture systems for predicting cell growth and differentiation in the microgravity environment of space. These completely fluid-filled bioreactors, which are oriented horizontally and rotate, have proven advantageous for Earth-based culture of three-dimensional cell assemblies, tissue-like aggregates, and glandular structures. Use of microgravity bioreactors for establishing in vitro models to investigate steroid-mediated secretion of EGF by normal SG cells may also prove useful for the investigation of cancer and other salivary gland disorders. These microgravity bioreactors promise challenging opportunities for future applications in basic and applied cell research.

NASA Program Space Biology↗

Mueller-matrix mapping of optically anisotropic fluorophores of biological tissues in the diagnosis of cancer

We report the results of studying the polarisation manifestations of laser autofluorescence of optically anisotropic structures in biological tissues. A Mueller-matrix model is proposed to describe their complex anisotropy (linear and circular birefringence, linear and circular dichroism). The relationship is established between the mechanisms of optical anisotropy and polarisation manifestations of laser autofluorescence of histological sections of rectal tissue biopsy in different spectral regions. The ranges of changes in the statistical moments of the 1st-to-4th orders, which describe the distribution of the azimuth-invariant elements of Mueller matrices of rectal tissue autofluorescence, are found. Effectiveness of laser autofluorescence polarimetry is determined and the histological sections of biopsy of benign (polyp) and malignant (adenocarcinoma) tumours of the rectal wall are differentiated for the first time. (laser biophotonics)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A New Approach to Reduce Uncertainties in Space Radiation Cancer Risk Predictions

The prediction of space radiation induced cancer risk carries large uncertainties with two of the largest uncertainties being radiation quality and dose-rate effects. In risk models the ratio of the quality factor (QF) to the dose and dose-rate reduction effectiveness factor (DDREF) parameter is used to scale organ doses for cosmic ray proton and high charge and energy (HZE) particles to a hazard rate for γ-rays derived from human epidemiology data. In previous work, particle track structure concepts were used to formulate a space radiation QF function that is dependent on particle charge number Z, and kinetic energy per atomic mass unit, E. QF uncertainties where represented by subjective probability distribution functions (PDF) for the three QF parameters that described its maximum value and shape parameters for Z and E dependences. Here I report on an analysis of a maximum QF parameter and its uncertainty using mouse tumor induction data. Because experimental data for risks at low doses of γ-rays are highly uncertain which impacts estimates of maximum values of relative biological effectiveness (RBE max ), I developed an alternate QF model, denoted QF γAcute where QFs are defined relative to higher acute γ-ray doses (0.5 to 3 Gy). The alternate model reduces the dependence of risk projections on the DDREF, however a DDREF is still needed for risk estimates for high-energy protons and other primary or secondary sparsely ionizing space radiation components. Risk projections (upper confidence levels (CL)) for space missions show a reduction of about 40% (CL~50%) using the QF γAcute model compared the QFs based on RBE max and about 25% (CL~35%) compared to previous estimates. In addition, I discuss how a possible qualitative difference leading to increased tumor lethality for HZE particles compared to low LET radiation and background tumors remains a large uncertainty in risk estimates.

59 BASIC BIOLOGICAL SCIENCES↗

Absolute Dosimetry Model of the University of Washington Clinical Neutron Therapy System (CNTS)

The University of Washington (UW) Clinical Neutron Therapy System (CNTS) generates a fast neutron beam using 50.5 MeV protons incident on a beryllium target. The CNTS is mainly used for fast neutron therapy in the treatment of cancer but is also used for radiation effects testing and the production of rare isotopes, or isotopes with a short half-life, for medical imaging and therapy. The accelerator and treatment head is modeled using the MCNP6 Monte Carlo code to enable beam characterization (neutron and photon fluence, linear energy transfer, secondary particle production), study the behavior of neutron dosimeters and ionization chamber (IC) responses, and to conduct first principle studies of the relative biological effectiveness (RBE) of fast neutrons compared to {sup 60}Co γ-rays. Measurements of neutron dose in selected CNTS fields were made using a model-17 ion chamber (IC-17) flowing methane-based, tissue-equivalent (TE) gas. As a first approximation, we compared IC-17 measurements to the MCNP calculated dose in a thin layer of water at selected locations along the central axis of the beam. To examine the impact of the composition of the chamber fill-gas and the chamber design characteristics, we also developed a high-resolution (∼ 50 μm) MCNP model of the IC-17 from a computerized tomography (CT) scan. Initial results indicate that the dose response of the IC-17 ion chamber is up to 30% larger (smaller?) compared to the dose to water for neutrons with energies >20 MeV. Differences in chamber and water response as large as 800% occur for neutrons with kinetic energies below 1 keV. The simulations of IC-17 response (and dose to water) for CNTS fast neutron spectra match measured doses within 4.6% for all field sizes and irradiation geometries considered. This reported studies provide additional evidence establishing use of the IC-17 ion chamber model or a thin layer of water as a reasonable surrogate for CNTS fast neutron dose calculations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Synergistically killing activity of aspirin and histone deacetylase inhibitor valproic acid (VPA) on hepatocellular cancer cells

Highlights: •Novel combination therapy using aspirin and valproic acid (VPA). •Combination of aspirin and VPA elicits synergistic cytotoxic effects. •Combination of aspirin and VPA significantly reduces the drug dosage required alone. •Combination of aspirin and VPA significantly inhibit tumor growth. •Lower dose of aspirin in combination therapy will minimize side effects of aspirin. -- Abstract: Aspirin and valproic acid (VPA) have been extensively studied for inducing various malignancies growth inhibition respectively, despite their severe side effects. Here, we developed a novel combination by aspirin and VPA on hepatocellular cancer cells (HCCs). The viability of HCC lines were analyzed by MTT assay, apoptotic analysis of HepG2 and SMMC-7721 cell was performed. Real time-PCR and Western blotting were performed to determine the expression of apoptosis related genes and proteins such as Survivin, Bcl-2/Bax, Cyclin D1 and p15. Moreover, orthotopic xenograft tumors were challenged in nude mice to establish murine model, and then therapeutic effect was analyzed after drug combination therapy. The viability of HCC lines’ significantly decreased after drug combination treatment, and cancer cell apoptosis in combination group increasingly induced compared with single drug use. Therapeutic effect was significantly enhanced by combination therapy in tumor volume and tumor weight decrease. From the data shown here, aspirin and VPA combination have a synergistic killing effect on hepatocellular cancers cells proliferation and apoptosis.

60 APPLIED LIFE SCIENCES↗

Feasibility of a Multigroup Deterministic Solution Method for Three-Dimensional Radiotherapy Dose Calculations

Purpose: To investigate the potential of a novel deterministic solver, Attila, for external photon beam radiotherapy dose calculations. Methods and Materials: Two hypothetical cases for prostate and head-and-neck cancer photon beam treatment plans were calculated using Attila and EGSnrc Monte Carlo simulations. Open beams were modeled as isotropic photon point sources collimated to specified field sizes. The sources had a realistic energy spectrum calculated by Monte Carlo for a Varian Clinac 2100 operated in a 6-MV photon mode. The Attila computational grids consisted of 106,000 elements, or 424,000 spatial degrees of freedom, for the prostate case, and 123,000 tetrahedral elements, or 492,000 spatial degrees of freedom, for the head-and-neck cases. Results: For both cases, results demonstrate excellent agreement between Attila and EGSnrc in all areas, including the build-up regions, near heterogeneities, and at the beam penumbra. Dose agreement for 99% of the voxels was within the 3% (relative point-wise difference) or 3-mm distance-to-agreement criterion. Localized differences between the Attila and EGSnrc results were observed at bone and soft-tissue interfaces and are attributable to the effect of voxel material homogenization in calculating dose-to-medium in EGSnrc. For both cases, Attila calculation times were <20 central processing unit minutes on a single 2.2-GHz AMD Opteron processor. Conclusions: The methods in Attila have the potential to be the basis for an efficient dose engine for patient-specific treatment planning, providing accuracy similar to that obtained by Monte Carlo.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cost-Effectiveness Analysis of Stereotactic Body Radiation Therapy Compared With Radiofrequency Ablation for Inoperable Colorectal Liver Metastases

Purpose: To conduct a cost-effectiveness analysis to determine whether stereotactic body radiation therapy (SBRT) is a cost-effective therapy compared with radiofrequency ablation (RFA) for patients with unresectable colorectal cancer (CRC) liver metastases. Methods and Materials: A cost-effectiveness analysis was conducted using a Markov model and 1-month cycle over a lifetime horizon. Transition probabilities, quality of life utilities, and costs associated with SBRT and RFA were captured in the model on the basis of a comprehensive literature review and Medicare reimbursements in 2014. Strategies were compared using the incremental cost-effectiveness ratio, with effectiveness measured in quality-adjusted life years (QALYs). To account for model uncertainty, 1-way and probabilistic sensitivity analyses were performed. Strategies were evaluated with a willingness-to-pay threshold of $100,000 per QALY gained. Results: In base case analysis, treatment costs for 3 fractions of SBRT and 1 RFA procedure were $13,000 and $4397, respectively. Median survival was assumed the same for both strategies (25 months). The SBRT costs $8202 more than RFA while gaining 0.05 QALYs, resulting in an incremental cost-effectiveness ratio of $164,660 per QALY gained. In 1-way sensitivity analyses, results were most sensitive to variation of median survival from both treatments. Stereotactic body radiation therapy was economically reasonable if better survival was presumed (>1 month gain) or if used for large tumors (>4 cm). Conclusions: If equal survival is assumed, SBRT is not cost-effective compared with RFA for inoperable colorectal liver metastases. However, if better local control leads to small survival gains with SBRT, this strategy becomes cost-effective. Ideally, these results should be confirmed with prospective comparative data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Disparities in the Use of Postmastectomy Radiation Therapy for Inflammatory Breast Cancer

Purpose: Although radiation therapy improves locoregional control and survival for inflammatory breast cancer (IBC), it is underused in this population. The purpose of this study was to identify variables associated with the underuse of postmastectomy radiation therapy (PMRT) for IBC. Methods and Materials: Using the 1998 to 2011 National Cancer Data Base, we identified 8273 women who underwent mastectomy for nonmetastatic IBC. We used logistic regression modeling to determine the demographic, tumor, and treatment variables associated with the underuse of PMRT. Results: Although the use of PMRT increased over time, a total of 30.3% of our cohort did not receive PMRT. On multivariate analysis, variables associated with the underuse of PMRT for IBC included the following (all P<.05): Medicare insurance (odds ratio [OR] = 0.70), annual income <$34,999 (<$30,000: OR=0.79; $30,000-$34,999: OR=0.82), cN2 and cN0 disease (cN2: OR=0.71; cN0: OR=0.63), failure to receive chemotherapy and hormone therapy (chemotherapy: OR=0.15; hormone therapy: OR=0.35), treatment at lower-volume centers (OR=0.83), and treatment in the South and West (South: OR=0.73; West: OR=0.80). Greater distance between patient's residence and radiation facility was also associated with the underuse of PMRT (P=.0001). Conclusions: Although the use of PMRT for IBC has increased over time, it continues to be underused. Disparities related to a variety of variables impact which IBC patients receive PMRT. A concerted effort must be made to address these disparities in order to optimize the outcomes for IBC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Antineoplastic activity of Salmonella Typhimurium outer membrane nanovesicles

Highlights: • ST-OMVs is a promising antitumor monotherapy or as an adjuvant to chemotherapies. • ST-OMVs downregulated Ki-67 and upregulated CD49b immune-expression. • ST-OMVs downregulated angiogenesis by inhibiting VEGF gene expression. • ST-OMVs increased tumor cells apoptosis and autophagy (increased caspase-3and Beclin1). Nano-sized Gram-negative bacterial outer membrane vesicles possess unique structural and immunostimulatory effects that could be exploited to regress tumors by alerting the host immune system and reversing the immunosuppressive tumor microenvironment. The current study was conducted to investigate the antitumor activity of the outer membrane vesicles (ST-OMVs) of Salmonella Typhimurium ATCC 14028, in vitro in human colorectal carcinoma (HTC116), breast cancer (MCF-7), and hepatocellular carcinoma (HepG2) cell lines and in vivo in Ehrlich solid carcinoma-bearing mice model either as a mono-immunotherapy or as an adjuvant to a commonly used conventional chemotherapy. In addition, we investigated the safety of ST-OMVs. Adult Swiss albino female mice with transplanted Ehrlich solid carcinoma were treated with either ST-OMVs, paclitaxel or a combination of both. Tumor volume, growth inhibition rate, quantitative RT-PCR of Bax and VEGF genes expression, histopathology and immune-expression of caspase-3, Beclin-1, CD49b and Ki-67 were all analyzed. Our results showed that ST-OMVs significantly decreased tumor volume, significantly increased tumor growth inhibition rate, up-regulated the immunohistochemical expression of caspase-3, Beclin-1, and CD49b (enhanced recruitment of NK cells). Furthermore, ST-OMVs down-regulated the expression of Ki-67, increased Bax gene expression and decreased VEGF gene expression as detected by qRT-PCR analysis. Histologically, ST-OMVs promoted apoptosis, decreased tumor invasion and mitotic activities. Moreover, ST-OMVs showed a remarkable cytotoxic activity in various investigated in vitro cancer cell lines. Our findings demonstrate potential antitumor activity of ST-OMVs that might be used as a promising safe antitumor immunotherapy or an adjuvant to conventional chemotherapeutic drugs, resolving some of their problems.

60 APPLIED LIFE SCIENCES↗

Dose to the Contralateral Breast From Radiotherapy and Risk of Second Primary Breast Cancer in the WECARE Study

Purpose: To quantify the risk of second primary breast cancer in the contralateral breast (CB) after radiotherapy (RT) for first breast cancer. Methods and Materials: The study population included participants in the Women's Environmental, Cancer, and Radiation Epidemiology study: 708 cases (women with asynchronous bilateral breast cancer) and 1399 controls (women with unilateral breast cancer) counter-matched on radiation treatment. Participants were <55 years of age at first breast cancer. Absorbed doses to quadrants of the CB were estimated. Rate ratios (RR) and 95% confidence intervals (CI) were calculated using multivariable-adjusted conditional logistic regression models. Results: Across all patients, the mean radiation dose to the specific quadrant of the CB tumor was 1.1 Gy. Women <40 years of age who received >1.0 Gy of absorbed dose to the specific quadrant of the CB had a 2.5-fold greater risk for CB cancer than unexposed women (RR = 2.5, 95% CI 1.4-4.5). No excess risk was observed in women >40 years of age. Women <40 years of age with follow-up periods >5 years had a RR of 3.0 (95% CI 1.1-8.1), and the dose response was significant (excess RR per Gy of 1.0, 95% CI 0.1-3.0). Conclusions: Women <40 years of age who received a radiation dose >1.0 Gy to the CB had an elevated, long-term risk of developing a second primary CB cancer. The risk is inversely related to age at exposure and is dose dependent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-C-BRF-01: Correlation of DIBH Breath Hold Amplitude with Dosimetric Sparing of Heart and Left Anterior Descending Artery in Left Breast Radiotherapy

Purpose: A 7.4% increase in major coronary events per 1 Gy increase in mean heart dose has been reported from the population-based analysis of radiation-induced cardiac toxicity following treatment of left sided breast cancer. Deep inhalation breath-hold (DIBH) is clinically utilized to reduce radiation dose to heart and left anterior descending artery (LAD). We investigated the correlation of dose sparing in heart and LAD with internal DIBH amplitude to develop a quantitative predictive model for expected dose to heart and LAD based on internal breath hold amplitude. Methods: A treatment planning study (Prescription Dose = 50 Gy) was performed on 50 left breast cancer patients underwent DIBH whole breast radiotherapy. Two CT datasets, free breathing (FB) and DIBH, were utilized for treatment planning and for determination of the internal anatomy DIBH amplitude (difference between sternum position at FB and DIBH). The heart and LAD dose between FB and DIBH plans was compared and dose to the heart and LAD as a function of breath hold amplitude was determined. Results: Average DIBH amplitude using internal anatomy was 13.9±4.2 mm. The DIBH amplitude-mean dose reduction correlation is 20%/5mm (0.3 Gy/5mm) for the heart and 18%/5mm (1.1 Gy/5mm) for LAD. The correlation with max dose reduction is 12%/5mm (3.8 Gy/5mm) for the heart and 16%/5mm (3.2 Gy/5mm) for LAD. We found that average dose reductions to LAD from 6.0±6.5 Gy to 2.0±1.6 Gy with DIBH (4.0 Gy reduction: -67%, p < 0.001) and average dose reduction to the heart from 1.3±0.7 Gy to 0.7±0.2 Gy with DIBH (0.6 Gy reduction: -46%, p < 0.001). That suggests using DIBH may reduce the risk of the major coronary event for left sided breast cancer patients. Conclusion: The correlation between breath hold amplitude and dosimetric sparing suggests that dose sparing linearly increases with internal DIBH amplitude.

60 APPLIED LIFE SCIENCES↗

Patient-Specific Quality Assurance for Prostate Cancer Patients Receiving Spot Scanning Proton Therapy Using Single-Field Uniform Dose

Purpose: To describe our experiences with patient-specific quality assurance (QA) for patients with prostate cancer receiving spot scanning proton therapy (SSPT) using single-field uniform dose (SFUD). Methods and Materials: The first group of 249 patients with prostate cancer treated with SSPT using SFUD was included in this work. The scanning-beam planning target volume and number of monitor units were recorded and checked for consistency. Patient-specific dosimetric measurements were performed, including the point dose for each plan, depth doses, and two-dimensional (2D) dose distribution in the planes perpendicular to the incident beam direction for each field at multiple depths. The {gamma}-index with 3% dose or 3-mm distance agreement criteria was used to evaluate the 2D dose distributions. Results: We observed a linear relationship between the number of monitor units and scanning-beam planning target volume. The difference between the measured and calculated point doses (mean {+-} SD) was 0.0% {+-} 0.7% (range, -2.9% to 1.8%). In general, the depth doses exhibited good agreement except at the distal end of the spread-out Bragg peak. The pass rate of {gamma}-index (mean {+-} SD) for 2D dose comparison was 96.2% {+-} 2.6% (range, 90-100%). Discrepancies between the measured and calculated dose distributions primarily resulted from the limitation of the model used by the treatment planning system. Conclusions: We have established a patient-specific QA program for prostate cancer patients receiving SSPT using SFUD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of Radiation Pneumonitis Risk Using a Generalized Lyman Model

Purpose: To introduce a version of the Lyman normal-tissue complication probability (NTCP) model adapted to incorporate censored time-to-toxicity data and clinical risk factors and to apply the generalized model to analysis of radiation pneumonitis (RP) risk. Methods and Materials: Medical records and radiation treatment plans were reviewed retrospectively for 576 patients with non-small cell lung cancer treated with radiotherapy. The time to severe (Grade {>=}3) RP was computed, with event times censored at last follow-up for patients not experiencing this endpoint. The censored time-to-toxicity data were analyzed using the standard and generalized Lyman models with patient smoking status taken into account. Results: The generalized Lyman model with patient smoking status taken into account produced NTCP estimates up to 27 percentage points different from the model based on dose-volume factors alone. The generalized model also predicted that 8% of the expected cases of severe RP were unobserved because of censoring. The estimated volume parameter for lung was not significantly different from n = 1, corresponding to mean lung dose. Conclusions: NTCP models historically have been based solely on dose-volume effects and binary (yes/no) toxicity data. Our results demonstrate that inclusion of nondosimetric risk factors and censored time-to-event data can markedly affect outcome predictions made using NTCP models.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-J-199: Predictive Models for Cone Beam CT-Based Online Verification of Pencil Beam Scanning Proton Therapy

Purpose: To utilize online CBCT scans to develop models for predicting DVH metrics in proton therapy of head and neck tumors. Methods: Nine patients with locally advanced oropharyngeal cancer were retrospectively selected in this study. Deformable image registration was applied to the simulation CT, target volumes, and organs at risk (OARs) contours onto each weekly CBCT scan. Intensity modulated proton therapy (IMPT) treatment plans were created on the simulation CT and forward calculated onto each corrected CBCT scan. Thirty six potentially predictive metrics were extracted from each corrected CBCT. These features include minimum/maximum/mean over and under-ranges at the proximal and distal surface of PTV volumes, and geometrical and water equivalent distance between PTV and each OARs. Principal component analysis (PCA) was used to reduce the dimension of the extracted features. Three principal components were found to account for over 90% of variances in those features. Datasets from eight patients were used to train a machine learning model to fit these principal components with DVH metrics (dose to 95% and 5% of PTV, mean dose or max dose to OARs) from the forward calculated dose on each corrected CBCT. The accuracy of this model was verified on the datasets from the 9th patient. Results: The predicted changes of DVH metrics from the model were in good agreement with actual values calculated on corrected CBCT images. Median differences were within 1 Gy for most DVH metrics except for larynx and constrictor mean dose. However, a large spread of the differences was observed, indicating additional training datasets and predictive features are needed to improve the model. Conclusion: Intensity corrected CBCT scans hold the potential to be used for online verification of proton therapy and prediction of delivered dose distributions.

60 APPLIED LIFE SCIENCES↗

MicroRNA library screening identifies growth-suppressive microRNAs that regulate genes involved in cell cycle progression and apoptosis

Micro(mi)RNAs play important and varied roles in tumorigenesis; however, the full repertoire of miRNAs that affect cancer cell growth is not known. In this study, an miRNA library was screened to identify those that affect the growth of A549 tumor cells. Among 300 miRNAs, miR-28-5p, -323-5p, -510-5p, -552-3p, and -608 were the most effective in inhibiting cell growth. More specifically, overexpressing miR-28-5p, -323-5p, and -510-5p induced G1 arrest, as determined by flow cytometry, whereas that of miR-608 induced cell death in a caspase-dependent manner. Moreover, several genes involved in apoptosis and cell cycle progression were downregulated upon overexpression of each of the five miRNAs, with the functional targets of miR-552-3p and miR-608 confirmed by microarray, quantitative real-time PCR, and luciferase reporter assay. In miR-608-transfected cells, B cell lymphoma 2-like 1 (BCL2L1), D-type cyclin 1 (CCND1), CCND3, cytochrome b5 reductase 3 (CYB5R3), phosphoinositide 3-kinase regulatory subunit 2 (PIK3R2), specificity protein 1 (SP1), and phosphorylated Akt were all downregulated, while Bcl-2-interacting killer (BIK) was upregulated. Moreover, miR-608 was determined to have a suppressive function on tumor growth in an NCI-H460 xenograft model. These findings provide insights into the roles of five miRNAs in growth inhibition and their potential function as cancer therapeutics. - Highlights: • MicroRNAs (miRNAs) affecting cancer cell growth were identified through a screen. • Five miRNAs that inhibit cell proliferation and survival were identified. • MiRNAs modulate various target genes to inhibit cancer cell growth. • These five miRNAs can potentially serve as new agents for cancer treatment.

60 APPLIED LIFE SCIENCES↗

Translating dosimetry of Dibenzo[ def,p ]chrysene (DBC) and metabolites across dose and species using physiologically based pharmacokinetic (PBPK) modeling

We report that Dibenzo[def,p]chrysene (DBC) is an environmental polycyclic aromatic hydrocarbon (PAH) that causes tumors in mice and has been classified as a probable human carcinogen by the International Agency for Research on Cancer. Animal toxicity studies often utilize higher doses than are found in relevant human exposures. Additionally, like many PAHs, DBC requires metabolic bioactivation to form the ultimate toxicant, and species differences in DBC and DBC metabolite metabolism have been observed. To understand the implications of dose and species differences, a physiologically based pharmacokinetic model (PBPK) for DBC and major metabolites was developed in mice and humans. Metabolism parameters used in the model were obtained from experimental in vitro metabolism assays using mice and human hepatic microsomes. PBPK model simulations were evaluated against mice dosed with 15 mg/kg DBC by oral gavage and human volunteers orally microdosed with 29 ng of DBC. DBC and its primary metabolite DBC-11,12-diol were measured in blood of mice and humans, while in urine, the majority of DBC metabolites were obeserved as conjugated DBC-11,12-diol, conjugated DBC tetrols, and unconjugated DBC tetrols. The PBPK model was able to predict the time course concentrations of DBC, DBC-11,12-diol, and other DBC metabolites in blood and urine of human volunteers and mice with reasonable accuracy. Agreement between model simulations and measured pharmacokinetic data in mice and human studies demonstrate the success and versatility of our model for interspecies extrapolation and applicability for different doses. Furthermore, our simulations show that internal dose metrics used for risk assessment do not necessarily scale allometrically, and that PBPK modeling provides a reliable approach to appropriately account for interspecies differences in metabolism and physiology.

59 BASIC BIOLOGICAL SCIENCES↗