Search NASA⌕ Search

SEARCH · Search NASA

Results for “Capacity estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Electric Utility Distribution Costs: Scoping Study on Trends, Drivers, and Possible Response Strategies [Slides]

This scoping study synthesizes information that will help stakeholders understand the scope, scale, and drivers of recent increases in investor-owned utility (IOU) expenditures on local distribution power grids, while providing regulators and other decision-makers with potential strategies to keep electricity bills down. The study includes five distinct components. Drawing first on data from FERC Form 1, it summarizes key trends in past and recent IOU distribution costs. Next, through a review of a sample of distribution-system plans, it characterizes material drivers of planned distribution expenditures. Ultimately, regulators must approve cost recovery for IOU expenditures, including those for the distribution system. The study therefore also: examines trends in utility requests and regulatory approvals related to changes in retail rates and return on equity; identifies areas where utility shareholder and customer incentives may be misaligned; and develops a menu of options that state regulators might consider to optimize distribution system expenditures. Some of the key findings include: - IOU distribution spending at a national level has grown by 6%/yr since 2014 in real dollar terms, 4x faster than in the prior 20 years and consisting mostly of capital (not operating) expenditure. - On a per-kWh basis, increases in IOU distribution costs since 2014 represent over 30% of the overall national-average increase in retail electricity rates. - Regional spending growth has ranged from 2-8%/yr, with larger estimated rate impacts in CAISO, then NYISO & ISO-NE, and then the Southeast, MISO & PJM (see figure). - Some utilities are planning for significantly increased distribution system spending. Planned spending on managing the existing system (asset replacement, safety & reliability, and resilience are all important drivers) exceeds that for capacity expansion. - IOU rate increase requests ($18 billion in 2025) and public utility commission (PUC) approval levels (average of 64% of requested amounts from 2021-2025) have recently hit multi-decadal highs. - PUCs in New England and the Southeast have recently approved a greater fraction of rate requests (>75%, on average) than in ther regions, while PUCs in California and the Southeast have generally authorized higher equity returns than in other regions. - Regulators have many tools to tackle potential misalignments between utility and customer interests and, more specifically, to optimize and reduce distribution costs. Shorter-term options include those related to return on equity, capital structure, depreciation, trackers, construction work in progress, and securitization. Longer-term options include performance-based regulation and a wide variety of planning-related requirements. All options embed important tradeoffs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design definition study of a life/cruise fan technology V/STOL aircraft. Volume 2, addendum 2: Program risk assessment

The results are presented of a risk assessment study conducted on two technology aircraft. The aircraft system components were reviewed and assessed for risk based on: (1) complexity relative to state-of-the-art, (2) manufacturing and qualification testing, (3) availability and delays, and (4) cost/schedule impact. These assessments were based on five risk nomenclatures: low, minor, moderate, high, and extreme. Each aircraft system was assigned an overall risk rating depending upon its contribution to the capability of the aircraft to achieve the performance goals. The slightly lower Sabreliner performance margin is due to the restricted flight envelope, the fixed landing gear, and internal fuel capacity. The Sabreliner with retractable gear and allowed to fly at its best speed and altitude would reflect performance margins similar to the New Airframe. These significant margins, inherent with the MCAIR three gas generator/three fan propulsion system, are major modifiers to risk assessment of both aircraft. The estimated risk and the associated key system and performance areas are tabulated.

Source record↗

The use of NOAA AVHRR data for assessment of the urban heat island effect

The objective of the study was to evaluate the use of a satellite-derived vegetation index and surface temperature estimates for the assessment of the difference in urban and rural air temperature due to the urban heat island effect. The difference in the ND (normalized difference) index between urban and rural regions appears to be an indicator of the difference in surface properties (evaporation and heat storage capacity) between the two environments that are responsible for the urban heat island effect. The use of the approach proposed here may provide a globally consistent method for assessing this phenomenon.

Gallo, K. P.↗

NASA Tech Briefs, November 2007

Topics include: Wireless Measurement of Contact and Motion Between Contact Surfaces; Wireless Measurement of Rotation and Displacement Rate; Portable Microleak-Detection System; Free-to-Roll Testing of Airplane Models in Wind Tunnels; Cryogenic Shrouds for Testing Thermal-Insulation Panels; Optoelectronic System Measures Distances to Multiple Targets; Tachometers Derived From a Brushless DC Motor; Algorithm-Based Fault Tolerance for Numerical Subroutines; Computational Support for Technology- Investment Decisions; DSN Resource Scheduling; Distributed Operations Planning; Phase-Oriented Gear Systems; Freeze Tape Casting of Functionally Graded Porous Ceramics; Electrophoretic Deposition on Porous Non- Conductors; Two Devices for Removing Sludge From Bioreactor Wastewater; Portable Unit for Metabolic Analysis; Flash Diffusivity Technique Applied to Individual Fibers; System for Thermal Imaging of Hot Moving Objects; Large Solar-Rejection Filter; Improved Readout Scheme for SQUID-Based Thermometry; Error Rates and Channel Capacities in Multipulse PPM; Two Mathematical Models of Nonlinear Vibrations; Simpler Adaptive Selection of Golomb Power-of- Two Codes; VCO PLL Frequency Synthesizers for Spacecraft Transponders; Wide Tuning Capability for Spacecraft Transponders; Adaptive Deadband Synchronization for a Spacecraft Formation; Analysis of Performance of Stereoscopic-Vision Software; Estimating the Inertia Matrix of a Spacecraft; Spatial Coverage Planning for Exploration Robots; and Increasing the Life of a Xenon-Ion Spacecraft Thruster.

Source record↗

Initial in Situ Measurements of Perennial Meltwater Storage in the Greenland Firn Aquifer

A perennial storage of water in a firn aquifer was discovered in southeast Greenland in 2011. We present the first in situ measurements of the aquifer, including densities and temperatures. Water was present at depths between approx. 12 and 37m and amounted to 18.7 +/- 0.9 kg in the extracted core. The water filled the firn to capacity at approx. 35m. Measurements show the aquifer temperature remained at the melting point, representing a large heat reservoir within the firn. Using model results of liquid water extent and aquifer surface depth from radar measurements, we extend our in situ measurements to the Greenland ice sheet. The estimated water volume is 140 +/- 20 Gt, representing approx. 0.4mm of sea level rise (SLR). It is unknown if the aquifer temporary buffers SLR or contributes to SLR through drainage and/or ice dynamics.

measurements↗

A Technology Architecture for Accessing the Oceans of Icy Worlds

The icy moon oceans beckon with ingredients that potentially may harbour extant life. Beginning with the Galileo and Cassini missions, measurements have revealed the presence of global oceans under the icy crust of several moons of Jupiter and Saturn. Among those moons, Europa and Enceladus have their ocean in contact with the rocky core, providing an environment similar to the conditions existing on the terrestrial sea-floor where life has developed at hydrothermal vents Accessing these oceans presents considerable difficulty due to a number of issues including the depth and composition of the icy crust, the time needed to travel through the crust, the power needed to propel a probe, communication of scientific and engineering data though the ice and back to Earth, entry and mobility in the ocean and autonomous operations for the life of the mission. A detailed trade space study was conducted to develop a technology architecture defining a system that would access an icy moon’s ocean. To specifically bound the architecture, Jupiter’s moon Europa was chosen as the target body though the work can apply to other bodies. The current understanding of the scientific properties of the ice crust and ocean was used to guide the development. A strawman scientific payload was devised to further develop a baseline set of requirements. Beginning with a launch and trajectory that can bring a system to Europa’s orbit, a complete trade space was developed outlining the engineering systems needed to access the ocean. The architecture was divided into specific phases for i) deorbit, descent and landing, ii) surface operations, iii) ice descent and iv) ocean access. The technical maturity of each of sub-system for the phases was assessed for systems that could be developed to a maturity ready for a preliminary design in less than ten years. Integrated system parameters on power, communication capacity, and mass were developed to further define the overall system. To constrain the design, a total time in the ice, from the ice crust surface to accessing the ocean was limited to three years, and 15Km of ice was baselined with a temperature profile through the ice estimated from the scientific literature.

Sengupta, Anita↗

Analysis of the Electrical Grid for UAM

A wide range of challenges must be overcome to conduct Urban Air Mobility (UAM) operations at scale with electric vertical takeoff and landing aircraft as envisioned. This presentation is on an analysis of one potential infrastructure challenge for UAM: available electrical grid power capacity. The success of UAM depends on the availability of electricity, which will be increasingly impacted by the proliferation of ground electric vehicles over time. Under the best-case assumption that electricity can be transmitted and distributed as needed within each interconnection (i.e., electrical grid), it is estimated that the maximum number of UAM aircraft that can charge simultaneously in the continental United States will decrease by 20% from about 595 thousand in the year 2021 to about 475 thousand in the year 2050 due to the projected increase in ground electric vehicles.

electrical grid; urban air mobility; electric vehi↗

System-level logistics modeling of DPC direct disposal - 15511

The U.S. Department of Energy (DOE), Office of Used Nuclear Fuel Disposition, has been conducting a study of the technical feasibility of direct disposal of existing dual-purpose canisters (DPCs) loaded with commercial spent nuclear fuel (SNF). The system-level logistical modeling described here is a part of this study with the primary goals to project the inventory of DPCs in the future and to understand the timing of DPC disposal constrained by thermal power limits for disposal and other key parameters of the waste management system. The logistics simulations also allow for estimating fuel age at emplacement, an important consideration if storage time is limited. This analysis evaluated the effects on DPC direct disposal from uncertainty in repository emplacement power limits, the repository start date, and whether or when the nuclear industry could transition to loading SNF into the smaller capacity multi-purpose canisters (MPCs). MPCs implemented at a future date would likely contain the youngest fuel with highest burnup, but smaller MPCs would cool to the emplacement power limits relatively quickly. The results of this analysis demonstrate that DPC direct disposal could be complete by about 2070 to 2170 depending on the repository emplacement power limit. These completion dates can be expedited by approximately 10 to 40 years in some scenarios through the transition to MPCs. The greatest average SNF age at emplacement is 88 years in the scenarios with the smallest repository thermal power limit in which no transition to MPCs is considered. Transition to MPCs could decrease the average age at emplacement, to as low as 42 years in some scenarios. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The reaction mechanism of FeSb 2 as anode for sodium-ion batteries

The electrochemical reaction of FeSb 2 with Na is reported for the first time. The first discharge (sodiation) potential profile of FeSb 2 is characterized by a gentle slope centered at 0.25 V. During charge (Na removal) and the subsequent discharge, the main reaction takes place near 0.7 V and 0.4 V, respectively. The reversible storage capacity amounts to 360 mA h g -1 , which is smaller than the theoretical value of 537 mA h g -1 . The reaction, studied by ex situ and in situ X-ray diffraction, is found to proceed by the consumption of crystalline FeSb 2 to form an amorphous phase. Upon further sodiation, the formation of nanocrystalline Na3Sb domains is evidenced. During desodiation, Na 3 Sb domains convert into an amorphous phase. The chemical environment of Fe, probed by 57 Fe Mo ssbauer spectroscopy, undergoes significant changes during the reaction. During sodiation, the well-resolved doublet of FeSb2 with an isomer shift around 0.45 mm s -1 and a quadrupole splitting of 1.26 mm s -1 is gradually converted into a doublet line centered at about 0.15 mm s1 along with a singlet line around 0 mm s -1 . The former signal results from the formation of a Fe-rich FexSb alloy with an estimated composition of Fe4Sb while the latter signal corresponds to superparamagnetic Fe due to the formation of nanosized pure Fe domains. Interestingly the signal of Fe4Sb remains unaltered during desodiation. This mechanism is substantially different than that observed during the reaction with Li. The irreversible formation of a Fe-rich Fe 4 Sb alloy and the absence of full desodiation of Sb domains explain the lower than theoretical practical storage capacity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Adsorptive separation and recovery of triacetic acid lactone from fermentation broth

Triacetic acid lactone (TAL), an emerging bioprivileged molecule, can be produced microbially and further chemically upgraded to several high-value chemicals. In this work, several acidic and basic ion-exchange resins and activated charcoal were evaluated for their ability to adsorb microbially produced TAL. Activated charcoal and a weak base resin, Dowex 66, showed similar TAL adsorption capacity of 0.18 ± 0.002 g/g. At 15% w/v activated charcoal, about 98% of TAL present in fermentation broth could be adsorbed. Further, ethanol washing allowed recovery of 72% of adsorbed TAL. A biorefinery producing TAL from sucrose was designed, simulated, and evaluated (through technoeconomic analysis) under uncertainty, for an estimated TAL minimum product selling price (MPSP) of $\$4.27$/kg ($\$3.71$–4.94/kg; 5th–95th percentiles) given the current state of technology and $\$2.83$/kg ($\$2.46$–3.29/kg) following potential near-term improvements to fermentation. This work provides an adsorptive process for the recovery of microbially produced TAL that can be upgraded chemically to a range of industrial products.

09 BIOMASS FUELS↗

PV Fleet Performance Data Initiative Program and Methodology

The US Department of Energy’s PV Fleet Performance Data Initiative has been launched in order to collect and evaluate production data across multiple PV fleet partners. Performance statistics are anonymized, aggregated and shared to represent a snapshot of the US commercial and utility-scale fleet. Production data have been collected from over 1500 systems representing more than 1.3 GWdc capacity. Preliminary analysis indicates median performance loss rates are in line with previous publications of system degradation, on the order of –0.6%/yr to –0.9%/yr (preliminary numbers subject to change). These values are higher than module-only degradation rates which are often used in pro-forma estimates of project performance and economics, potentially exposing owner/operators to increased risk if systems under-perform over time.

41 EE - Solar Energy Technologies Office (EE-4S)↗

BioSTEAMDevelopmentGroup/Bioindustrial-Park/TAL

Triacetic acid lactone (TAL) can be microbially produced and further chemically upgraded to several high-value chemicals. In this work, several acidic and basic ion-exchange resins and activated charcoal were evaluated for their ability to adsorb microbially produced TAL. Activated charcoal and a weak base resin, Dowex 66, showed similar TAL adsorption capacity of 0.18 ± 0.002 g/g. At 15% w/v activated charcoal, about 98% of TAL present in fermentation broth could be adsorbed. Further, ethanol washing allowed recovery of 72% of adsorbed TAL. A biorefinery producing TAL from sucrose was designed, simulated, and evaluated (through technoeconomic analysis) under uncertainty, for an estimated TAL minimum product selling price (MPSP) of $4.27/kg [$3.71−4.94/kg; 5th-95th percentiles] for the current state of technology and $2.83/kg [$2.46–3.29/kg] following potential near-term improvements to fermentation. Thus, this work provides an adsorptive process to recover microbially produced TAL that can be chemically upgraded to several industrial products.

Cortes-Peña, Yoel↗

Benchmarking Wind Power Operating Costs in the United States: Results from a Survey of Wind Industry Experts

This paper draws on a survey of wind industry professionals to clarify trends in the operational expenditures (OpEx) of U.S. land-based wind power plants. The paper also highlights key drivers of those trends. We find that average all-in lifetime OpEx has declined from approximately $\$$80/kW-yr ($\$$35/MWh) for projects built in the late 1990s to a level that is approaching $\$$40/kW-yr ($\$$11/MWh) for projects under construction in 2018. Turbine operations and maintenance (O&M) costs—inclusive of scheduled and unscheduled maintenance—represent the single largest component of overall OpEx and the primary source of cost reductions over the last decade. We observe wide ranges of OpEx over time; for example, survey respondents cite a range in average expected costs for projects commissioned between 2015 and 2018 from $\$$33/kW-yr to $\$$59/kW-yr. Notably, these broad ranges include high levels of variability in both turbine O&M costs and non-turbine OpEx. Potential technical and strategic drivers of this variability are highlighted. We also use historical OpEx learning rates, showing a 9% OpEx reduction for each doubling of global installed wind capacity, to project a further $\$$5–$\$$8/kW-yr (12%–18%) OpEx reduction from 2018 to 2040. When compared with the broader literature, these findings suggest that continued OpEx reductions may contribute 10% or more of the expected reductions in land-based wind’s levelized cost of energy. Moreover, these estimates may understate the importance of OpEx owing to the multiplicative effects through which operational advancements influence not only O&M costs but also component reliability, performance, and plant-level availability—thereby affecting levelized costs though OpEx reduction and by enhancing annual energy production and plant lifetimes. Given the limited quantity and comparability of previously available OpEx data, the data and trends reported here may usefully inform OpEx assumptions used by electric system planners, analysts, modelers, and research and development managers. The results may also provide useful benchmarks to the wind industry, helping developers and asset owners compare their OpEx expectations with historical experience and other industry projections.

17 WIND ENERGY↗

Semiconductor: Supply Chain Deep Dive Assessment

In February 2021, President Biden signed Executive Order (EO) 14017, “America’s Supply Chains,” directing seven executive agencies to evaluate the resilience and security of the nation’s critical supply chains and to craft strategies for six industrial bases that underpin America’s economic and national security. See Sec. 3(b) of E.O. 14017. As part of the one-year response to EO 14017, the U.S. Department of Energy (DOE), through the national laboratories, conducted evaluations of the supply chains that encompass the Energy Sector Industrial Base, with a particular focus on technologies required to decarbonize the U.S. by 2050. This report focuses on one of these technologies, semiconductors, both conventional and wide bandgap (WBG) power electronics (PE). As noted in the 100-Day report, conventional semiconductors are a keystone technology that are essential for the operation of nearly every electronic device, including those that are critical to decarbonization, such as electric vehicles (EVs), industrial and building applications, and electricity generation and end use. In addition, power electronics have been applied to industrial equipment to improve energy efficiency and enhance controllability. Power electronics have also been used to improve the reliability of data centers and critical infrastructure, including the stabilization of the electric grid while subjected to disturbances. Increasingly, power electronics are being used to integrate renewable energy and battery storage systems, enabling new grid services and the development of microgrids. It is estimated that 30% of the electricity used in the U.S. passes through power electronic devices, and studies suggest that this number could reach 80% as power electronics are deployed in more markets. Nearly all forms of electrified transportation will depend on power electronics. Power electronic systems utilize high-capacity semiconductor devices at their core. The continued growth in power electronics depends on sustained innovation in the semiconductor industry.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Heat capacities of liquid metals above 1500 K

Heat capacity data are presented for liquid transition metals for temperatures close to the melting point and for 3000, 4000, and 5000 K. The data have been obtained by summarizing the results of levitation, exploding-wire, and drop-calorimetry measurements reported in the literature and by providing analytical estimates where experimental data are not available. The data given here are useful in assigning heat loads and predicting structure survival during extreme temperature excursions caused by nuclear, laser, or particle irradiations.

Margrave, J. L.↗

An Observationally Constrained Evaluation of the Oxidative Capacity in the Tropical Western Pacific Troposphere

Hydroxyl radical (OH) is the main daytime oxidant in the troposphere and determines the atmospheric lifetimes of many compounds. We use aircraft measurements of O3, H2O, NO, and other species from the Convective Transport of Active Species in the Tropics (CONTRAST) field campaign, which occurred in the tropical western Pacific (TWP) during January-February 2014, to constrain a photochemical box model and estimate concentrations of OH throughout the troposphere. We find that tropospheric column OH (OHCOL) inferred from CONTRAST observations is 12 to 40% higher than found in chemical transport models (CTMs), including CAM-chem-SD run with 2014 meteorology as well as eight models that participated in POLMIP (2008 meteorology). Part of this discrepancy is due to a clear-sky sampling bias that affects CONTRAST observations; accounting for this bias and also for a small difference in chemical mechanism results in our empirically based value of OHCOL being 0 to 20% larger than found within global models. While these global models simulate observed O3 reasonably well, they underestimate NOx (NO +NO2) by a factor of 2, resulting in OHCOL approx.30% lower than box model simulations constrained by observed NO. Underestimations by CTMs of observed CH3CHO throughout the troposphere and of HCHO in the upper troposphere further contribute to differences between our constrained estimates of OH and those calculated by CTMs. Finally, our calculations do not support the prior suggestion of the existence of a tropospheric OH minimum in the TWP, because during January-February 2014 observed levels of O3 and NO were considerably larger than previously reported values in the TWP.

Hydroxyl radical↗

Analysis of Electrical Grid Capacity by Interconnection for Urban Air Mobility

A wide range of challenges must be overcome to conduct Urban Air Mobility (UAM)operations at scale with electric vertical take-off and landing aircraft as envisioned. This paper documents an analysis of one potential infrastructure challenge for UAM: available electrical grid power capacity. The success of UAM depends on the availability of electricity, which will be increasingly impacted by the proliferation of ground electric vehicles(EVs) over time. Under the best-case assumption that electricity can be transmitted and distributed as needed within each interconnection (i.e., electrical grid), it is estimated that the maximum number of UAM aircraft that can charge simultaneously in the continental United States will decrease by 20% from about 595 thousand in the year 2021 to about 475 thousand in the year 2050due to the projected increase in ground EVs.

electrical grid↗

Analysis of Electrical Grid Capacity by Interconnection for Urban Air Mobility

A wide range of challenges must be overcome to conduct Urban Air Mobility (UAM)operations at scale with electric vertical take-off and landing aircraft as envisioned. This paper documents an analysis of one potential infrastructure challenge for UAM: available electrical grid power capacity. The success of UAM depends on the availability of electricity, which will be increasingly impacted by the proliferation of ground electric vehicles(EVs) over time. Under the best-case assumption that electricity can be transmitted and distributed as needed within each interconnection (i.e., electrical grid), it is estimated that the maximum number of UAM aircraft that can charge simultaneously in the continental United States will decrease by 20% from about 595 thousand in the year 2021 to about 475 thousand in the year 2050due to the projected increase in ground EVs.

electrical grid↗