Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cold”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Prefibrillar transthyretin oligomers and cold stored native tetrameric transthyretin are cytotoxic in cell culture

Recent studies suggest that soluble, oligomeric species, which are intermediates in the fibril formation process in amyloid disease, might be the key species in amyloid pathogenesis. Soluble oligomers of human wild type transthyretin (TTR) were produced to elucidate oligomer properties. Employing ThT fluorescence, time-resolved fluorescence anisotropy of pyrene-labeled TTR, chemical cross-linking, and electron microscopy we demonstrated that early formed soluble oligomers (within minutes) from A-state TTR comprised on the average 20-30 TTR monomers. When administered to neuroblastoma cells these early oligomers proved highly cytotoxic and induced apoptosis after 48 h of incubation. More mature fibrils (>24 h of fibrillation) were non-toxic. Surprisingly, we also found that native tetrameric TTR, when purified and stored under cold conditions (4 deg. C) was highly cytotoxic. The effect could be partially restored by increasing the temperature of the protein. The cytotoxic effects of native tetrameric TTR likely stems from a hitherto unexplored low temperature induced rearrangement of the tetramer conformation that possibly is related to the conformation of misfolded TTR in amyloigogenic oligomers.

60 APPLIED LIFE SCIENCES↗

Comprehensive Analysis of Model Parameter Uncertainty Influence on Evaluation of HVAC Operation to Mitigate Indoor Virus: A Case Study for an Office Building in a Cold and Dry Climate

Simulation-based studies of HVAC operation to mitigate indoor virus have been conducted to understand tradeoffs between indoor air quality (IAQ) and energy consumption. However, the influence of model parameter uncertainty in these studies has not been systematically quantified, which is critical when providing guidance to building operators. To address this gap, we identify 20 model parameters for a typical medium office building system in a cold and dry climate that can influence IAQ and energy consumption for indoor virus scenarios. Next, the distributions of the parameter values are estimated from literature and a set of simulation samples for three representative days is generated that simultaneously sample all of the parameters from their distributions. Two HVAC virus mitigation strategies are studied: increased filtration using MERV 13 filters and increased ventilation, via supply of 100% outdoor air into buildings. The model parameter uncertainty leads to significant variability in the results, particularly for the IAQ because of the highly uncertain virus generation rate. Use of 100% outdoor air can be beneficial for some uncertain scenarios on the hot day, but shows less IAQ improvement and/or significant energy increases on the other days. The virus removal efficiency and pressure drop of the HVAC filter, fan efficiency, and internal heat gain are the most important parameters to determining the tradeoffs of the two strategies. Our results demonstrate how this model parameter uncertainty analysis methodology can provide practical guidance to building operators.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mechanical ventilation and indoor air quality in recently constructed U.S. homes in marine and cold-dry climates

Data were collected to characterize whole-house mechanical ventilation (WHMV) and indoor air quality (IAQ) in 55 homes in the Marine climate of Oregon and the Cold-Dry climate of Colorado in the U.S. Sixteen homes were monitored for two weeks, with and without WHMV operating. Ventilation airflows; airtightness; time-resolved CO 2 , PM2.5 and radon; and time-integrated NO 2 , NO X and formaldehyde were measured. Participants provided information about IAQ-impacting activities, perceptions and ventilation use. All homes had operational cooktop ventilation and bathroom exhaust. Thirty homes had equipment that could meet the ASHRAE 62.2–2010 standard with continuous or controlled runtime and 34 had some WHMV operating as found. Thirty-five of 46 participants with WHMV reported they did not know how to operate it, and only half of the systems were properly labeled. Two-week homes had lower formaldehyde, radon, CO 2 and NO (NO X -NO 2 ) when operated with WHMV, and had faster PM 2.5 decays following indoor emission events. Overall IAQ satisfaction was similar in Oregon and Colorado, but more Colorado participants (19% vs 3%) felt their IAQ could be improved and more reported dryness as a problem (58% vs. 14%). The collected data indicate that there are benefits of operating WHMV, even when continuous use may not be needed because outdoor pollutant concentrations are low and indoor sources do not present substantial challenges.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pre-existing humoral immunity to human common cold coronaviruses negatively impacts the protective SARS-CoV-2 antibody response

SARS-CoV-2 infection causes diverse outcomes ranging from asymptomatic infection to respiratory distress and death. A major unresolved question is whether prior immunity to endemic, human common cold coronaviruses (hCCCoVs) impacts susceptibility to SARS-CoV-2 infection or immunity following infection and vaccination. Therefore, we analyzed samples from the same individuals before and after SARS-CoV-2 infection or vaccination. We found hCCCoV antibody levels increase after SARS-CoV-2 exposure, demonstrating cross-reactivity. However, a case-control study indicates that baseline hCCCoV antibody levels are not associated with protection against SARS-CoV-2 infection. Rather, higher magnitudes of pre-existing betacoronavirus antibodies correlate with more SARS-CoV-2 antibodies following infection, an indicator of greater disease severity. Additionally, immunization with hCCCoV spike proteins before SARS-CoV-2 immunization impedes the generation of SARS-CoV-2-neutralizing antibodies in mice. Together, these data suggest that pre-existing hCCCoV antibodies hinder SARS-CoV-2 antibody-based immunity following infection and provide insight on how pre-existing coronavirus immunity impacts SARS-CoV-2 infection, which is critical considering emerging variants.

60 APPLIED LIFE SCIENCES↗

RF-transpond: A 1D coupled cold plasma wave and plasma transport model for ponderomotive force driven density modification parallel to B

The RF-Transpond code couples a fluid plasma transport solver with a frequency domain cold plasma RF wave solver in a 1D domain parallel to a strong background magnetic field. A ponderomotive force term proportional to parallel gradients in the electric field strength is included in the transport model in order to describe ponderomotive effects in the scrape-off layer (SOL) of fusion plasmas. The transport and wave codes are verified independently and a coupled case corresponding to experimental parameters from the LArge Plasma Device (LAPD) is presented. The density perturbation ratio R n , calculated to describe ponderomotive force driven modifications, is up to 20% for the simulation inputs used.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A preference for cold dark matter over Superfluid Dark Matter in local Milky Way data

There are many well-known correlations between dark matter and baryons that exist on galactic scales. These correlations can essentially be encompassed by a simple scaling relation between observed and baryonic accelerations, historically known as the Mass Discrepancy Acceleration Relation (MDAR). The existence of such a relation has prompted many theories that attempt to explain the correlations by invoking additional fundamental forces on baryons. The standard lore has been that a theory that reduces to the MDAR on galaxy scales but behaves like cold dark matter (CDM) on larger scales provides an excellent fit to data, since CDM is desirable on scales of clusters and above. However, this statement should be revised in light of recent results showing that a fundamental force that reproduces the MDAR is challenged by local Milky Way dynamics and rotation curve data between 5–18 kpc. In this study, we test this claim on the example of Superfluid Dark Matter. We find that a standard CDM model is preferred over a static superfluid profile assuming a steady-state Galactic disk and discuss the robustness of this conclusion to disequilibrium effects. This preference is due to the fact that the superfluid model over-predicts vertical accelerations, even while reproducing galactic rotation curves. Our results establish an important criterion that any dark matter model must satisfy within the Milky Way.

79 ASTRONOMY AND ASTROPHYSICS↗

Nanostructure TEM analysis of diamond cold cathode field emitters

Diamond cold cathode devices have demonstrated significant potential as electron field emitters. Ultra-sharp diamond pyramidal tips (~5nm tip radius) have been fabricated and show improvement in emission when compared to conventional field emitters. However, the emission mechanisms in these complex diamond nanostructures are not well understood. Transmission electron microscopy performed in this study provides new insight into tip structure and composition with implications for field emission and diamond growth.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Hot, cold, or just right? An infrared biometric sensor to improve occupant comfort and reduce overcooling in buildings via closed-loop control

To improve occupant comfort and save energy in buildings, we have developed a closed-loop air conditioning (AC) sensor-controller that predicts occupant thermal sensation from the thermographic measurement of skin temperature distribution, then uses this information to reduce overcooling (cooling-energy overuse that discomforts occupants) by regulating AC output. Taking measures to protect privacy, it combines thermal-infrared (TIR) and color (visible spectrum) cameras with machine vision to measure the skin-surface temperature profile. Since the human thermoregulation system uses skin blood flow to maintain thermoneutrality, the distribution of skin temperature can be used to predict warm, neutral, and cool thermal states. We conducted a series of human-subject thermal-sensation trials in cold-to-hot environments, measuring skin temperatures and recording thermal sensation votes. We then trained random-forest classification machine-learning models (classifiers) to estimate thermal sensation from skin temperatures or skin-temperature differences. The estimated thermal sensation was input to a proportional integral (PI) control algorithm for the AC, targeting a sensation level between neutral and warm. Our sensor-controller includes a sensor assembly, server software, and client software. The server software orients the cameras and transmits images to the client software, which in turn assesses occupant skin temperature distribution, estimates occupant thermal sensation, and controls AC operation. A demonstration conducted in a conference room in an office building near Houston, TX showed that our system reduced overcooling, decreasing AC load by 42% when the room was occupied while improving occupant comfort (fraction of “comfortable” votes) by 15 percentage points.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of heating and cooling loads on battery energy storage system sizing in extreme cold climates

Efficient operation of battery energy storage systems requires that battery temperature remains within a specific range. Current techno-economic models neglect the parasitic loads heating and cooling operations have on these devices, assuming they operate at constant temperature. In this work, these effects are investigated considering the optimal sizing of battery energy storage systems when deployed in cold environments. Here, a peak shaving application is presented as a linear programming problem which is then formulated in the PYOMO optimization programming language. The building energy simulation software EnergyPlus is used to model the heating, ventilation, and air conditioning load of the battery energy storage system enclosure. Case studies are conducted for eight locations in the United States considering a nickel manganese cobalt oxide lithium ion battery type and whether the power conversion system is inside or outside the enclosure. The results show an increase of 42% to 300% in energy capacity size, 43% to 217% in power rating, and 43% to 296% increase in capital cost dependent on location. This analysis shows that the heating, ventilation, and air conditioning load can have a large impact on the optimal sizes and cost of a battery energy storage system and merit consideration in techno-economic studies.

25 ENERGY STORAGE↗

Empirical analysis of electric vehicle fast charging under cold temperatures

This paper presents an empirical analysis of the effects of temperature on Direct Current Fast Charger (DCFC) charging rate and discusses the impact of such effects on wider adoptions of electric vehicles (EVs). The authors conducted statistical analysis on the effects of temperature and constructed an electric vehicle charging model that can show the dynamics of DCFC charging process under different temperatures. The results indicate that DCFC charging rate can deteriorate considerably in cold temperatures. These findings may be used as a reference to identify and assess the regions that may suffer from slow charging. In conclusion, the problems associated with temperature effects on DCFC charging deserve greater attention as electrification of motor vehicles progresses and DCFC usage increases in the future.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Rolling Optimization of Transmission Network Recovery and Load Restoration Considering Hybrid Wind-Storage System and Cold Load Pickup

A common solution to deal with the stochasticity introduced by fast-ramping wind power integration is to equip wind farms (WFs) with energy storage systems (ESSs) to formulate hybrid WF-ESSs. In addition to leveling off wind power fluctuations during normal operations, a hybrid WF-ESS can be a flexible power source to accumulate the power system restoration. In this paper, we propose a rolling optimization model for transmission network recovery and load restoration considering the contributions of WF-ESSs. The proposed model is formulated as a mixed integer linear programming problem that simultaneously optimizes the amount and location of restorable load blocks as well as the restoration lines. The cold load pickup features of interrupted loads considering the outage duration are modeled in detail. A chance-constrained method is employed to deal with the uncertainty of wind power, and a rolling horizon-based framework is adopted to reduce the influence of forecast error. Case studies are conducted on both New England 39-bus system and part of a provincial power system in China. The results show that the load restoration process can be significantly accelerated by employing the proposed method and contributions of hybrid WF-ESSs to power system restoration are validated.

chance-constrained optimization↗

Evaluating Target Cold Spots By the use of Tail EUDs

Purpose: To propose a new measure of target underdose that can be used in the evaluation and optimization of radiotherapy dose distributions. Methods and Materials: We compare various formulations of the equivalent uniform dose (EUD) and introduce a modification of existing EUD definitions, which we call tail EUD. Tail EUD is a measure of 'cold spots' below the prescription dose in the target dose distribution, using units of gray (Gy). We investigate the mathematical properties of various target EUD concepts, including tail EUD. We apply the tail EUD measure retrospectively to intensity modulated radiation therapy (IMRT) treatment plans from our plan database. We also use tail EUD as an optimization objective in the optimization of prostate, pancreas, and head-and-neck plans. Results: Tail EUD has desirable mathematical properties. In particular, it is convex and it leads to convex level sets (i.e., no local minima) if the EUD from which it is derived is concave. The tail EUD value is correlated with the subjective degree of target coverage. Constraining tail EUDs to a certain level in plan optimization leads to comparable target coverage in different plans and treatment sites. Conclusions: The newly introduced concept of tail EUD appears to be useful for both plan evaluation and optimization. In addition it can potentially be applied in the design of new clinical protocols.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Periodic changes in effluent chemistry at cold-water geyser: Crystal geyser in Utah

Crystal geyser is a CO 2 -driven cold-water geyser which was originally drilled in the late 1930’s in Green River, Utah. By utilizing a suite of temporal groundwater sample datasets, in situ monitoring of temperature, pressure, pH and electrical conductivity from multiple field trips to Crystal geyser from 2007 to 2014, periodic trends in groundwater chemistry from the geyser effluent were identified. Based on chemical characteristics, the primary sourcing aquifers are characterized to be both the Entrada and Navajo Sandstones with a minor contribution from Paradox Formation brine. The single eruption cycle at Crystal geyser lasted over four days and was composed of four parts: Minor Eruption (mEP), Major Eruption (MEP), Aftershock Eruption (Ae) and Recharge (R). During the single eruption cycle, dissolved ionic species vary 0–44% even though the degree of changes for individual ions are different. Generally, Na + , K + , Cl - and SO 4 2- regularly decrease at the onset and throughout the MEP. These species then increase in concentration during the mEP. In contrast, Ca 2+ , Mg 2+ , Fe 2+ and Sr 2+ increase and decrease in concentration during the MEP and mEP, respectively. The geochemical inverse modeling with PHREEQC was conducted to characterize the contribution from three end-members (Entrada Sandstone, Navajo Sandstone and Paradox Formation brine) to the resulting Crystal geyser effluent. Results of the inverse modeling showed that, during the mEP, the Navajo, Entrada and brine supplied 62–65%, 36–33% and 1–2%, respectively. During the MEP, the contribution shifted to 53–56%, 45–42% and 1–2% for the Navajo, Entrada and Paradox Formation brine, respectively. Finally, these changes in effluent characteristics further support the hypothesis by Watson et al. (2014) that the mEP and MEP are driven by different sources and mechanisms.

54 ENVIRONMENTAL SCIENCES↗

Single particle impact explorations on the role of powder heat treatments in cold spray: Effects of strength and oxide structure

In cold spray, the optimization of the powder feedstock for improving the final properties of the coating and for improving the process itself are two different objectives. This paper explores the latter, studying the relationship between powder pre-heat treatment and the kinetic bonding between the individual particles and the substrate. Using a laser-induced particle impact test (LIPIT), we investigate the effect of different heat treatments on the critical adhesion velocity of Al 6061. Although heat treatments change the strength of the powders as well as the thickness of the native oxide layer each by as much as ∼50 %, the critical adhesion velocity remains constant to within only ∼10 %. A deeper analysis reveals that these two factors change in somewhat complementary ways for the heat treatments explored here, leading to counteracting effects. By quantitatively evaluating these two microstructural factors in tandem, we find that they are roughly equally important in determining the critical adhesion velocity. These observations thus provide insight for the development of new heat treatment regimens that might lower the adhesion velocity.

Al 6061↗

Cold crucible induction melter test for crystalline ceramic waste form fabrication: A feasibility assessment

The first scaled proof-of-principle cold crucible induction melter (CCIM) test to process a multiphase ceramic waste form from a simulated combined (Cs/Sr, lanthanide and transition metal fission products) commercial used nuclear fuel waste stream was recently conducted in the United States. X-ray diffraction, 2-D X-ray absorption near edge structure (XANES), electron microscopy, inductively coupled plasma-atomic emission spectroscopy (and inductively coupled plasma-mass spectroscopy for Cs), and product consistency tests were used to characterize the fabricated CCIM material. Characterization analyses confirmed that a crystalline ceramic with a desirable phase assemblage was produced from a melt using a CCIM. We identified primary hollandite, pyrochlore/zirconolite, and perovskite phases in addition to minor phases rich in Fe, Al, or Cs. The material produced in the CCIM was chemically homogeneous and displayed a uniform phase assemblage with acceptable aqueous chemical durability.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Semi-integral LOCA test of cold-spray chromium coated zircaloy-4 accident tolerant fuel cladding

Enhancing the accident tolerance of PWRs came under serious consideration following the 2011 Fukushima Daiichi nuclear power plant events. While the current nuclear fuels are based on mature technology and have an excellent operational record, further enhancing their strength through accident tolerant fuel (ATF) research and development continues to be of interest. Particularly, the chromium coated clad ATF technology represents an evolutionary change to improve the high temperature performance of existing Zircaloy claddings. Additionally, despite several years of investigation of coated cladding, the integral loss of coolant accident (LOCA) performance of chromium coated cladding has had little attention. In this work, cold-spray chromium coated zircaloy-4 claddings are evaluated using EDF's semi-integral LOCA test facility. Results show that the chromium coating induces a reduced ballooning and burst and an increased burst temperature in the investigated conditions. However, these tests exhibit limited benefits concerning the post-quench behavior of the coated specimens which occurs in the last stage of a prototypical LOCA scenario.

36 MATERIALS SCIENCE↗

Annealing twin formation and recrystallization study of cold-drawn copper wires from EBSD measurements

The crystallographic texture and microstructure of an electrolytic tough pitch copper have been investigated by Electron Back Scattered Diffraction (EBSD) after cold wire drawing (reduction in area between 52% and 94%) and after primary recrystallization. The material presents a deformation texture composed of major <111> and minor <100> fibers. The evolution of the quality index of the Kikuchi patterns shows that the stored energy is lower in the <100> fiber than in the <111> fiber. Then, after recrystallization, the volume fraction of the <100> fiber increases at the expense of the other texture components. The study of the grain boundary nature shows that the recrystallization twin fraction decreases with increasing strain. It is shown that this evolution is the consequence of the grain size reduction.

36 MATERIALS SCIENCE↗

The effects of asymmetrical cold rolling on kinetics, grain size and texture in IF steels

Asymmetrical rolling is a promising way to achieve high rolling reductions and potentially grain refinement. However in steels the effect of asymmetrical rolling is not thoroughly quantified. In this paper the impact of cold asymmetrical rolling obtained by changing the roll velocity ratio (from 1.1 to 1.45) on the deformation and recrystallization features has been finely investigated by Electron Back-Scattering Diffraction in a Scanning Electron Microscope. In the investigated conditions (with low thickness reduction), it is found that asymmetrical rolling induces grain refinement and more homogeneous gamma fiber texture.

36 MATERIALS SCIENCE↗