Search NASA⌕ Search

SEARCH · Search NASA

Results for “Computational Method Validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Systematic study of the validity of the eikonal model including uncertainties

Nuclear reactions at intermediate beam energies are often interpreted using the eikonal model. In the analysis of complex reaction probes, where few-body reaction methods are needed, the eikonal method may be used as an efficient way for describing the fragment-target reaction process. In this work, we perform a systematic study to test the validity of the eikonal approximation for nucleon-nucleus reactions. We also quantify uncertainties due to the nucleon optical potential on reaction observables. We inspect the validity of the eikonal model and its semiclassical correction by comparing it to exact solutions (obtained from solving the optical-model equation with a finite-differences method) for a wide range of reactions. We also study the effect of relativistic corrections, both kinematic and dynamic, by effectively incorporating the relativistic effects at intermediate energies. The uncertainties from a Bayesian global optical potential (KDUQ) are propagated to the observables of interest. Our study includes neutron and proton reactions on 27 Al , 40 Ca , 90 Zr , and 208 Pb , for a wide range of energies 𝐸 lab = 0–400 MeV. We calculate neutron-total cross sections (elastic and reactions) as well as proton-absorption cross sections as a function of beam energy, using the eikonal model, the eikonal model with a semiclassical correction, and the exact solution. Here, we also compute angular distributions for the methods above. Our results show that for the proton-absorption cross section, the eikonal model can be used down to around 60 MeV and the semiclassical correction extends its use to 30 MeV. However, the validity of the eikonal model for the neutron-total cross section only goes down to ≈120 MeV, a range extended to ≈ 50 MeV when using the semiclassical correction. We find the semiclassical correction to the eikonal model to be less effective in describing the angular distributions. The 1⁢𝜎 uncertainty intervals on the observables we studied is less than 5% for most of the energies considered, but increases rapidly for higher energies, namely energies outside the range of KDUQ (𝐸 lab > 200MeV).

Cluster models↗

PET-Based Treatment Response Evaluation in Rectal Cancer: Prediction and Validation

Purpose: To develop a positron emission tomography (PET)-based response prediction model to differentiate pathological responders from nonresponders. The predictive strength of the model was validated in a second patient group, treated and imaged identical to the patients on which the predictive model was based. Methods and Materials: Fifty-one rectal cancer patients were prospectively included in this study. All patients underwent fluorodeoxyglucose (FDG) PET-computed tomography (CT) imaging both before the start of chemoradiotherapy (CRT) and after 2 weeks of treatment. Preoperative treatment with CRT was followed by a total mesorectal excision. From the resected specimen, the tumor regression grade (TRG) was scored according to the Mandard criteria. From one patient group (n = 30), the metabolic treatment response was correlated with the pathological treatment response, resulting in a receiver operating characteristic (ROC) curve based cutoff value for the reduction of maximum standardized uptake value (SUV{sub max}) within the tumor to differentiate pathological responders (TRG 1-2) from nonresponders (TRG 3-5). The applicability of the selected cutoff value for new patients was validated in a second patient group (n = 21). Results: When correlating the metabolic and pathological treatment response for the first patient group using ROC curve analysis (area under the curve = 0.98), a cutoff value of 48% SUV{sub max} reduction was selected to differentiate pathological responders from nonresponders (specificity of 100%, sensitivity of 64%). Applying this cutoff value to the second patient group resulted in a specificity and sensitivity of, respectively, 93% and 83%, with only one of the pathological nonresponders being false positively predicted as pathological responding. Conclusions: For rectal cancer, an accurate PET-based prediction of the pathological treatment response is feasible already after 2 weeks of CRT. The presented predictive model could be used to select patients to be considered for less invasive surgical interventions or even a 'wait and see' policy. Also, based on the predicted response, early modifications of the treatment protocol are possible, which might result in an improved clinical outcome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sharp front tracking with geometric interface reconstruction

Here, this paper presents a novel sharp front-tracking method designed to address limitations in classical front-tracking approaches, specifically their reliance on smooth interpolation kernels and extended stencils for coupling the front and fluid mesh. In contrast, the proposed method employs exclusively sharp, localized interpolation and spreading kernels, restricting the coupling to the interfacial fluid cells–those containing the interface/front. This localized coupling is achieved by integrating a divergence-preserving velocity interpolation method with a piecewise parabolic interface calculation (PPIC) and a polyhedron intersection algorithm to compute the indicator function and local interface curvature. Surface tension is computed using the Continuum Surface Force (CSF) method, maintaining consistency with the sharp representation. Additionally, we propose an efficient local roughness smoothing implementation to account for surface mesh undulations, which is easily applicable to any triangulated surface mesh. Building on our previous work, the primary innovation of this study lies in the localization of the coupling for both the indicator function and surface tension calculations. By reducing the interface thickness on the fluid mesh to a single cell, as opposed to the 4–5 cell spans typical in classical methods, the proposed sharp front-tracking method achieves a highly localized and accurate representation of the interface. This sharper representation mitigates parasitic currents and improves force balancing, making it particularly suitable for scenarios where the interface plays a critical role, such as microfluidics, fluid-fluid interactions, and fluid-structure interactions. The proposed method is comprehensively validated and tested on canonical interfacial flow problems, including stationary and translating Laplace equilibria, oscillating droplets, and rising bubbles. The presented results demonstrate that the sharp front-tracking method significantly outperforms the classical approach in terms of accuracy, stability, and computational efficiency. Notably, parasitic currents are reduced by approximately two orders of magnitude and stable results are obtained for parameter ranges where classical front tracking fails to converge.

42 ENGINEERING↗

Monte Carlo-based simulation of dynamic jaws tomotherapy

Purpose: Original TomoTherapy systems may involve a trade-off between conformity and treatment speed, the user being limited to three slice widths (1.0, 2.5, and 5.0 cm). This could be overcome by allowing the jaws to define arbitrary fields, including very small slice widths (<1 cm), which are challenging for a beam model. The aim of this work was to incorporate the dynamic jaws feature into a Monte Carlo (MC) model called TomoPen, based on the MC code PENELOPE, previously validated for the original TomoTherapy system. Methods: To keep the general structure of TomoPen and its efficiency, the simulation strategy introduces several techniques: (1) weight modifiers to account for any jaw settings using only the 5 cm phase-space file; (2) a simplified MC based model called FastStatic to compute the modifiers faster than pure MC; (3) actual simulation of dynamic jaws. Weight modifiers computed with both FastStatic and pure MC were compared. Dynamic jaws simulations were compared with the convolution/superposition (C/S) of TomoTherapy in the ''cheese'' phantom for a plan with two targets longitudinally separated by a gap of 3 cm. Optimization was performed in two modes: asymmetric jaws-constant couch speed (''running start stop,'' RSS) and symmetric jaws-variable couch speed (''symmetric running start stop,'' SRSS). Measurements with EDR2 films were also performed for RSS for the formal validation of TomoPen with dynamic jaws. Results: Weight modifiers computed with FastStatic were equivalent to pure MC within statistical uncertainties (0.5% for three standard deviations). Excellent agreement was achieved between TomoPen and C/S for both asymmetric jaw opening/constant couch speed and symmetric jaw opening/variable couch speed, with deviations well within 2%/2 mm. For RSS procedure, agreement between C/S and measurements was within 2%/2 mm for 95% of the points and 3%/3 mm for 98% of the points, where dose is greater than 30% of the prescription dose (gamma analysis). Dose profiles acquired in transverse and longitudinal directions through the center of the phantom were also compared with excellent agreement (2%/2 mm) between all modalities. Conclusions: The combination of weights modifiers and interpolation allowed implementing efficiently dynamic jaws and dynamic couch features into TomoPen at a minimal cost in terms of efficiency (simulation around 8 h on a single CPU).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

DSMC Simulations of Hypersonic Flows and Comparison With Experiments

This paper presents computational results obtained with the direct simulation Monte Carlo (DSMC) method for several biconic test cases in which shock interactions and flow separation-reattachment are key features of the flow. Recent ground-based experiments have been performed for several biconic configurations, and surface heating rate and pressure measurements have been proposed for code validation studies. The present focus is to expand on the current validating activities for a relatively new DSMC code called DS2V that Bird (second author) has developed. Comparisons with experiments and other computations help clarify the agreement currently being achieved between computations and experiments and to identify the range of measurement variability of the proposed validation data when benchmarked with respect to the current computations. For the test cases with significant vibrational nonequilibrium, the effect of the vibrational energy surface accommodation on heating and other quantities is demonstrated.

Moss, James N.↗

GTD analysis of airborne antennas radiating in the presence of lossy dielectric layers

The patterns of monopole or aperture antennas mounted on a perfectly conducting convex surface radiating in the presence of a dielectric or metal plate are computed. The geometrical theory of diffraction is used to analyze the radiating system and extended here to include diffraction by flat dielectric slabs. Modified edge diffraction coefficients valid for wedges whose walls are lossy or lossless thin dielectric or perfectly conducting plates are developed. The width of the dielectric plates cannot exceed a quarter of a wavelength in free space, and the interior angle of the wedge is assumed to be close to 0 deg or 180 deg. Systematic methods for computing the individual components of the total high frequency field are discussed. The accuracy of the solutions is demonstrated by comparisons with measured results, where a 2 lambda by 4 lambda prolate spheroid is used as the convex surface. A jump or kink appears in the calculated pattern when higher order terms that are important are not included in the final solution. The most immediate application of the results presented here is in the modelling of structures such as aircraft which are composed of nonmetallic parts that play a significant role in the pattern.

Rojas-Teran, R. G.↗

Strategic Plan for Nuclear Energy -- Knowledge Base for Advanced Modeling and Simulation (NE-KAMS)

The Nuclear Energy Computational Fluid Dynamics Advanced Modeling and Simulation (NE-CAMS) system is being developed at the Idaho National Laboratory (INL) in collaboration with Bettis Laboratory, Sandia National Laboratory (SNL), Argonne National Laboratory (ANL), Utah State University (USU), and other interested parties with the objective of developing and implementing a comprehensive and readily accessible data and information management system for computational fluid dynamics (CFD) verification and validation (V&V) in support of nuclear energy systems design and safety analysis. The two key objectives of the NE-CAMS effort are to identify, collect, assess, store and maintain high resolution and high quality experimental data and related expert knowledge (metadata) for use in CFD V&V assessments specific to the nuclear energy field and to establish a working relationship with the U.S. Nuclear Regulatory Commission (NRC) to develop a CFD V&V database, including benchmark cases, that addresses and supports the associated NRC regulations and policies on the use of CFD analysis. In particular, the NE-CAMS system will support the Department of Energy Office of Nuclear Energy Advanced Modeling and Simulation (NEAMS) Program, which aims to develop and deploy advanced modeling and simulation methods and computational tools for reliable numerical simulation of nuclear reactor systems for design and safety analysis. Primary NE-CAMS Elements There are four primary elements of the NE-CAMS knowledge base designed to support computer modeling and simulation in the nuclear energy arena as listed below. Element 1. The database will contain experimental data that can be used for CFD validation that is relevant to nuclear reactor and plant processes, particularly those important to the nuclear industry and the NRC. Element 2. Qualification standards for data evaluation and classification will be incorporated and applied such that validation data sets will result in well-defined, well-characterized data. Element 3. Standards will be established for the design and operation of experiments for the generation of new validation data sets that are to be submitted to NE-CAMS that addresses the completeness and characterization of the dataset. Element 4. Standards will be developed for performing verification and validation (V&V) to establish confidence levels in CFD analyses of nuclear reactor processes; such processes will be acceptable and recognized by both CFD experts and the NRC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Neutron source in the MCNPX shielding calculating for electron accelerator driven facility

Argonne National Laboratory (ANL) of USA and Kharkov Inst. of Physics and Technology (KIPT) of Ukraine have been collaborating on the design development of an experimental neutron source facility. It is an accelerator driven system (ADS) utilizing a subcritical assembly driven by electron accelerator. The facility will be utilized for performing basic and applied nuclear researches, producing medical isotopes, and training young nuclear specialists. Monte Carlo code MCNPX has been utilized as a design tool due to its capability to transport electrons, photons, and neutrons at high energies. However the facility shielding calculations with MCNPX need enormous computational resources and the small neutron yield per electron makes sampling difficulty for the Monte Carlo calculations. A method, based on generating and utilizing neutron source file, was proposed and tested. This method reduces significantly the required computer resources and improves the statistics of the calculated neutron dose outside the shield boundary. However the statistical errors introduced by generating the neutron source were not directly represented in the results, questioning the validity of this methodology, because an insufficiently sampled neutron source can cause error on the calculated neutron dose. This paper presents a procedure for the validation of the generated neutron source file. The impact of neutron source statistic on the neutron dose is examined by calculating the neutron dose as a function of the number of electron particles used for generating the neutron source files. When the value of the calculated neutron dose converges, it means the neutron source has scored sufficient records and statistic does not have apparent impact on the calculated neutron dose. In this way, the validity of neutron source and the shield analyses could be verified. (authors)

43 PARTICLE ACCELERATORS↗

On computing stress in polymer systems involving multi-body potentials from molecular dynamics simulation

Hardy stress definition has been restricted to pair potentials and embedded-atom method potentials due to the basic assumptions in the derivation of a symmetric microscopic stress tensor. Force decomposition required in the Hardy stress expression becomes obscure for multi-body potentials. In this work, we demonstrate the invariance of the Hardy stress expression for a polymer system modeled with multi-body interatomic potentials including up to four atoms interaction, by applying central force decomposition of the atomic force. The balance of momentum has been demonstrated to be valid theoretically and tested under various numerical simulation conditions. The validity of momentum conservation justifies the extension of Hardy stress expression to multi-body potential systems. Computed Hardy stress has been observed to converge to the virial stress of the system with increasing spatial averaging volume. This work provides a feasible and reliable linkage between the atomistic and continuum scales for multi-body potential systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Efficient particle control in systems with large density gradients

Simulations of large density gradients present a number of challenges for direct Monte Carlo methods, since they lead to too few particles in dilute regions and prohibitively many in the dense regions. Here, we propose a particle control methodology that gives the user more control of the number of particles per cell by introducing a variable weight for each particle. The proposed scheme is based on the stochastic weighted particle method, requires only small modifications to DSMC, and exactly conserves mass, momentum, and energy. In validation tests of systems with density ratios of order 102-104, we observe 101-102 times less variance in the dilute region compared to a DSMC solution with the same number of system particles, while introducing a moderate additional computational cost.

DSMC↗

On the Stability of a Linear System of Difference Equations with Random Parameters

We study the asymptotic behavior of solutions to a linear system of difference equation whose right-hand side at each time moment depends not only on the value at the previous moment, but also on a random parameter that takes its values in a given set. We obtain conditions of the Lyapunov stability and the asymptotic stability of the equilibrium position that are valid for all values of the random parameter or with probability 1.

97 MATHEMATICS AND COMPUTING↗

Stochastic modeling of evaporating sprays within a consistent hybrid joint PDF framework

In the present study, a framework for modeling two-phase evaporating flow is presented, which employs an Eulerian-Lagrangian-Lagrangian approach. For the continuous phase, a joint velocity-composition probability density function (PDF) method is used. Opposed to other approaches, such PDF methods require no modeling for turbulent convection and chemical source terms. For the dispersed phase, the PDF of velocity, diameter, temperature, seen gas velocity and seen gas composition is calculated. This provides a unified formulation, which allows to consistently address the different modeling issues associated with such a system. Because of the high dimensionality, particle methods are employed to solve the PDF transport equations. To further enhance computational efficiency, a local particle time-stepping algorithm is implemented and a particle time-averaging technique is employed to reduce statistical and bias errors. In comparison to previous studies, a significantly smaller number of droplet particles per grid cell can be employed for the computations, which rely on two-way coupling between the droplet and gas phases. The framework was validated using established experimental data and a good overall agreement can be observed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Studies of EMP generation using a Lienard-Wiechert formulation, and progress toward a 3-D EMP code

Here, we describe studies of the generation of electro-magnetic pulse (EMP) fields under the idealized conditions of a delta-function gamma pulse, a spherical cap of Compton electrons located at a common radius from the burst, and the absence of the conduction current. Various processes (geomagnetic rotation, drag, and scattering) contribute to the time derivative of the Compton current density, which appears as the source term in the Lienard–Wiechert expression for the radiation field. These processes are considered separately and in combination, and their influences on the waveform of the EMP assessed. Using a separate computational approach, different numerical models of multiple scattering are tested, in an effort to assess the validity of existing codes and earlier results. We also describe plans for and progress toward a comprehensive 3-D EMP code, which is to employ recently developed numerical methods and is to offer a variety of models, including the Lienard–Wiechert formulation described here.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Computed Tomography Radiomics Predicts HPV Status and Local Tumor Control After Definitive Radiochemotherapy in Head and Neck Squamous Cell Carcinoma

Purpose: This study aimed to predict local tumor control (LC) after radiochemotherapy of head and neck squamous cell carcinoma (HNSCC) and human papillomavirus (HPV) status using computed tomography (CT) radiomics. Methods and Materials: HNSCC patients treated with definitive radiochemotherapy were included in the retrospective study approved by the local ethical commission (93 and 56 patients in the training and validation cohorts, respectively). Three hundred seventeen CT radiomic features, including those based on shape, intensity, texture, and wavelet transform, were calculated in the primary tumor region. Cox and logistic regression models were built to predict LC and HPV status, respectively. The best-performing features in the univariable analysis were included in the multivariable analysis after the exclusion of redundant features. The quality of the models was assessed using the concordance index (CI) for modeling of LC and receiver operating characteristics area under the curve (AUC) for HPV status prediction. The radiomics LC model was compared to a model incorporating clinical parameters (tumor stage, volume, and HPV status) and a mixed model. Results: A radiomic signature comprising 3 features was significantly associated with LC (CI{sub training} = 0.75 and CI{sub validation} = 0.78), showing that tumors with a more heterogeneous CT density distribution are at risk for decreased LC. The addition of clinical parameters to the radiomics model slightly improved the model in the training cohort but not in the validation cohort. Another radiomic signature showed good performance in HPV status prediction (AUC{sub training} = 0.85 and AUC{sub validation} = 0.78) and indicated that HPV-positive tumors have a more homogenous CT density distribution. Conclusions: Heterogeneity of HNSCC tumor density, quantified by CT radiomics, is associated with LC after radiochemotherapy and HPV status.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Distinguishing correct from incorrect PML proposals and a corrected unsplit PML for anisotropic, dispersive media

We show that some previous proposals for perfectly matched layer (PML) absorbers in anisotropic media or for waveguides at oblique incidence are not, in fact true PMLs; in previous work we similarly showed a failure of several PML proposals for periodic media (photonic crystals). We therefore argue that a more careful validation scheme is required for PML proposals, in contrast to past authors who have typically checked only that reflections are small for a fixed resolution, and suggest a simple validation scheme that can be readily applied to any PML proposal regardless of derivation or implementation. We demonstrate this test for a corrected, unsplit-field PML valid for anisotropic, dispersive media, implemented in both planewave-expansion and finite-difference time-domain (FDTD) methods.

97 MATHEMATICS AND COMPUTING↗

Classical nuclear motion coupled to electronic non-adiabatic transitions

Based on the exact factorization of the electron-nuclear wave function, we have recently proposed a mixed quantum-classical scheme [A. Abedi, F. Agostini, and E. K. U. Gross, Europhys. Lett. 106, 33001 (2014)] to deal with non-adiabatic processes. Here we present a comprehensive description of the formalism, including the full derivation of the equations of motion. Numerical results are presented for a model system for non-adiabatic charge transfer in order to test the performance of the method and to validate the underlying approximations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Validation of a deformable image registration technique for cone beam CT-based dose verification

Purpose: As radiation therapy evolves toward more adaptive techniques, image guidance plays an increasingly important role, not only in patient setup but also in monitoring the delivered dose and adapting the treatment to patient changes. This study aimed to validate a method for evaluation of delivered intensity modulated radiotherapy (IMRT) dose based on multimodal deformable image registration (DIR) for prostate treatments. Methods: A pelvic phantom was scanned with CT and cone-beam computed tomography (CBCT). Both images were digitally deformed using two realistic patient-based deformation fields. The original CT was then registered to the deformed CBCT resulting in a secondary deformed CT. The registration quality was assessed as the ability of the DIR method to recover the artificially induced deformations. The primary and secondary deformed CT images as well as vector fields were compared to evaluate the efficacy of the registration method and it’s suitability to be used for dose calculation. PLASTIMATCH, a free and open source software was used for deformable image registration. A B-spline algorithm with optimized parameters was used to achieve the best registration quality. Geometric image evaluation was performed through voxel-based Hounsfield unit (HU) and vector field comparison. For dosimetric evaluation, IMRT treatment plans were created and optimized on the original CT image and recomputed on the two warped images to be compared. The dose volume histograms were compared for the warped structures that were identical in both warped images. This procedure was repeated for the phantom with full, half full, and empty bladder. Results: The results indicated mean HU differences of up to 120 between registered and ground-truth deformed CT images. However, when the CBCT intensities were calibrated using a region of interest (ROI)-based calibration curve, these differences were reduced by up to 60%. Similarly, the mean differences in average vector field lengths decreased from 10.1 to 2.5 mm when CBCT was calibrated prior to registration. The results showed no dependence on the level of bladder filling. In comparison with the dose calculated on the primary deformed CT, differences in mean dose averaged over all organs were 0.2% and 3.9% for dose calculated on the secondary deformed CT with and without CBCT calibration, respectively, and 0.5% for dose calculated directly on the calibrated CBCT, for the full-bladder scenario. Gamma analysis for the distance to agreement of 2 mm and 2% of prescribed dose indicated a pass rate of 100% for both cases involving calibrated CBCT and on average 86% without CBCT calibration. Conclusions: Using deformable registration on the planning CT images to evaluate the IMRT dose based on daily CBCTs was found feasible. The proposed method will provide an accurate dose distribution using planning CT and pretreatment CBCT data, avoiding the additional uncertainties introduced by CBCT inhomogeneity and artifacts. This is a necessary initial step toward future image-guided adaptive radiotherapy of the prostate.

60 APPLIED LIFE SCIENCES↗

Operational Reactor Depletion Analysis Capability

The milestone for the operational reactor depletion demonstrates a cycle depletion simulation of Watt's Bar Unit 1 Cycle 1. The simulation was performed using the VERA-CS components MPACT and COBRA-TF. The simulation was performed on the Titan and Eos machines at the Oak Ridge Leadership Computing Facility. The simulation results include the critical boron concentration, the pin resolved power, temperature, and fluid density distributions, and detector responses as a function of time. These results are presented and the critical boron concentration is compared with measured data. The comparison is reasonable given the modeling approximation used at this point. Several suggestions, both near and longer term, are given for areas of future work which include improving the methods, data, models, and computational performance. For those solution results which are not compared to measurement, e.g. power and temperature distributions, their behavior coincides with analysts' expectations. An important next step in the validation of VERA-CS will be the comparison of the computational results to the measured flux data. To satisfy this L1 milestone, numerous capabilities were successfully added as a part of supporting L2 and L3 milestones. These include: full core depletion, generation of a new cross section library, coupling of neutronics and thermal hydraulic feedback, and detector response modeling. In addition to the operational reactor depletion, several 2-D core parametric studies were performed to assess the new simulation capability and to develop guidelines on model approximations and discretizations. Some of the conclusions from these studies are: • The simulation of B-10 depletion in the coolant is necessary to accurately predict critical boron concentrations, • If the end of cycle state is of primary interest in the simulation, then significant approximations may be made in the cycle history. The ability to make use of this approximation without a notable loss in accuracy will considerably accelerate multi-cycle analysis, • The new 47-group cross section library with a transport correction of the P 0 scattering can provide solutions very efficiently and which are nearly as accurate as solutions generated with explicit P 2 scattering, and • Simplified modeling of the equilibrium xenon concentration is well predicted by the existing depletion solver, and only in certain circumstances (e.g. large and "instantaneous" changes to rod position or T/H conditions) would an explicit physical model need to be included. Overall the milestone is considered a success as the objectives were met and several new and important results were produced from this work. The results and conclusions of this milestone will continue to guide future work and become the basis for addressing the CASL Challenge Problems.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗