Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dose Code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Benchmark Exercise Report for Experimental Study of Bubble Scrubbing in Sodium Pool

Mechanistic source term (MST) analyses are likely to be an important part of advanced reactor licensing applications. For the purpose, an MST analysis code applicable to newly introduced advanced reactors, called SRT (Simplified Radionuclide Transport) code, has been developed by Argonne National Laboratory. SRT can track overall behaviors of radionuclides especially in metal fuel-based sodium fast reactors (SFRs) and microreactors. Throughout the simulation, migration inside fuel pins before failure, interaction with coolant (for SFR), removal/leakage in cover gas and containment (or confinement), and environmental dose impacts are considered alongside radioactive decay for short-lived nuclides. Among the postulated process, pool scrubbing phenomenon, especially under sodium pool condition, has been identified as high importance with limited supportive data. The phenomenon plays a crucial role in assessing the degree of radiological impacts as radioactive aerosols or vapors are efficiently and effectively removed during the process. To provide validation basis for SRT in assessing pool scrubbing performance inside sodium pools, the University of Wisconsin-Madison performed tests including extensive parametric effects. Separate effect tests were conducted to directly evaluate the SRT models and to estimate degree of contribution by each contributing factor. Specifically, bubble size, aerosol size, aerosol density, aerosol concentration, pool depth, system temperature, and bubble swarm effects were considered. According to the parametric effects, decontamination performance enhances with decreasing bubble size, large density, and deeper pool height. Aerosol concentration provides no effect for the whole range of interest, and pool temperature variation shows minor effects under the considered temperature condition. When multiple bubbles are injected generating a bubble swarm condition, DF performance further enhances by bubble interactions and turbulence characteristics. The measurement shows the exceptional importance of aerosol size range considered, with the lowest decontamination, where most radionuclides are expected to escape.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

OBJECT KINETIC MONTE CARLO SIMULATIONS OF RADIATION DAMAGE IN BULK TUNGSTEN

We used our recently developed lattice based OKMC code; KSOME [1] to carryout simulations of radiation damage in bulk W. We study the effect of dimensionality of self interstitial atom (SIA) diffusion i.e. 1D versus 3D on the defect accumulation during irradiation with a primary knock-on atom (PKA) energy of 100 keV at 300 K for the dose rates of 10-5 and 10-6 dpa/s. As expected 3D SIA diffusion significantly reduces damage accumulation due to increased probability of recombination events. In addition, dose rate, over the limited range examined here, appears to have no effect in both cases of SIA diffusion.

Nandipati, Giridhar↗

Extension of OpenMC for Fixed Source Transmutation Calculations

This report documents work performed under a Strategic Partnership Project between Argonne National Laboratory (ANL) and the United Kingdom Atomic Energy Authority (UKAEA). The overall goal of this project is to extend OpenMC [1], a community-developed Monte Carlo particle transport code, to be able to perform fixed-source transmutation calculations. In fission and fusion reactors, the high flux of energetic neutrons causes materials within the reactor to “transmute,” or undergo a nuclear reaction that results in the addition/removal of neutrons and protons from the nucleus of an atom. If subjected to these reactions for long enough, the overall composition and physical properties of the material itself begin to change as a result of transmutation. Such a feature is vital for predicting the decrease in tritium production rate within a breeder blanket during the lifetime of a fusion reactor. OpenMC is capable of simulating neutron transport in fission/fusion systems, thereby allowing it to estimate the flux that causes transmutation. It is also capable of solving the transmutation equations, which determine how the composition of a material changes over time due to neutron irradiation and radioactive decay. However, solving the transmutation equations was previously only possible when the source of neutrons came from a fission system. In a fusion system, the source of neutrons is typically determined by a separate code and then given as an input to the particle transport simulation. This is known as a fixed source calculation. Through this project, we have extended OpenMC to solve the transmutation equations for a fixed source calculation. Evaluating the change in material compositions due to transmutation and its effect on physical properties is of key importance to a range of engineering analyses for fission and fusion systems. For example, in a fusion reactor, estimating the dose rate at different physical locations resulting from irradiated materials in the reactor allows designers to ensure that workers are not exposed to doses beyond applicable regulations. In order to properly dispose of irradiated materials, designers also need to estimate the radiotoxicity, which again relies on knowledge of the material composition at some future time. The specific tasks for this project that were agreed to between ANL and UKAEA were as follows: 1. Make changes and additions in the openmc.deplete and related modules in OpenMC to support transmutation calculations following a fixed source transport simulation. 2. Make necessary changes to OpenMC to model transmutation due to an arbitrary set of reactions needed for fusion applications. Use this new capability to generate a depletion chain file based on the TENDL nuclear data library. 3. Improve the openmc.deplete module in OpenMC to keep track of gases produced as a by-product of nuclear reactions during transmutation calculations. 4. Validate the new capabilities by carrying out fixed-source transmutation calculations on a suitable benchmark problem using OpenMC and a comparable Monte Carlo neutron transport code.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Technical Note: Influence of the phantom material on the absorbed-dose energy dependence of the EBT3 radiochromic film for photons in the energy range 3 keV–18 MeV

Purpose: Water is the reference medium for radiation therapy dosimetry, but for film dosimetry it is more practical to use a solid phantom. As the composition of solid phantoms differs from that of water, the energy dependence of film exposed within solid phantoms may also differ. The energy dependence of a radiochromic film for a given beam quality Q (energy for monoenergetic beams) has two components: the intrinsic energy dependence and the absorbed-dose energy dependence f(Q), the latter of which can be calculated through a Monte Carlo simulation of radiation transport. The authors used Monte Carlo simulations to study the influence of the phantom material on the f(Q) of the EBT3 radiochromic film (Ashland Specialty Ingredients, Wayne, NJ) for photon beams with energies between 3 keV and 18 MeV. Methods: All simulations were carried out with the general-purpose Monte Carlo code PENELOPE 2011. The geometrical model consisted of a cylindrical phantom, with the film positioned at different depths depending on the initial photon energy. The authors simulated monoenergetic parallel photon beams and x-ray beams from a superficial therapy system. To validate their choice of simulation parameters, they also calculated f(Q) for older film models, EBT and EBT2, comparing with published results. In addition to water, they calculated f(Q) of the EBT3 film for solid phantom materials commonly used for film dosimetry: RW1 and RW3 (PTW-Freiburg, Freiburg, Germany), Solid Water (Gammex-RMI, Madison, WI), and PMMA. Finally, they combined their calculated f(Q) with published overall energy response data to obtain the intrinsic energy dependence of the EBT3 film in water. Results: The calculated f(Q) for EBT and EBT2 films was statistically compatible with previously published data. Between 10 keV and 18 MeV, the variation found in f(Q) of the EBT3 film for water was within 2.3%, with a standard statistical uncertainty less than 1%. If the quantity dose-to-water in the phantom is considered, which is the common practice in radiation dosimetry, the maximum difference of energy dependence for the solid phantoms with respect to water is about 6%, at an energy of 50 keV. Conclusions: The EBT3 film shows a reasonably constant absorbed-dose energy dependence when irradiated in water. If the dose-to-water in the phantom is considered, the maximum difference of EBT3 film energy dependence with the solid phantoms studied with respect to water is about 6% (at an energy of 50 keV). The reported overall energy dependence of the EBT3 film in water at energies below 100 keV is mainly due to the intrinsic energy dependence.

07 ISOTOPE AND RADIATION SOURCES↗

Microdosimetric study on influence of low energy photons on relative biological effectiveness under therapeutic conditions using 6 MV linac

Purpose: Microdosimetry has been developed for the evaluation of radiation quality, and single-event dose-mean lineal energy y{sub D} is well-used to represent the radiation quality. In this study, the changes of the relative biological effectiveness (RBE) values under the therapeutic conditions using a 6 MV linac were investigated with a microdosimetric method. Methods: The y{sub D} values under the various irradiation conditions for x-rays from a 6 MV linac were measured with a tissue-equivalent proportional counter (TEPC) at an extremely low dose rate of a few tens of {mu}Gy/min by decreasing the gun grid voltage of the linac. According to the microdosimetric kinetic model (MK model), the RBE{sub MK} values for cell killing of the human salivary gland (HSG) tumor cells can be derived if the y{sub D} values are obtained from TEPC measurements. The Monte Carlo code GEANT4 was also used to calculate the photon energy distributions and to investigate the changes of the y{sub D} values under the various conditions. Results: The changes of the y{sub D} values were less than approximately 10% when the field size and the depth in a phantom varied. However, in the measurements perpendicular to a central beam axis, large changes were observed between the y{sub D} values inside the field and those outside the field. The maximum increase of approximately 50% in the y{sub D} value outside the field was obtained compared with those inside the field. The GEANT4 calculations showed that there existed a large relative number of low energy photons outside of the field as compared with inside of the field. The percentages of the photon fluences below 200 keV outside the field were approximately 40% against approximately 8% inside the field. By using the MK model, the field size and the depth dependence of the RBE{sub MK} values were less than approximately 2% inside the field. However, the RBE{sub MK} values outside the field were 6.6% higher than those inside the field. Conclusions: The increase of the RBE{sub MK} values by 6.6% outside the field was observed. This increase is caused by the change of the photon energy distributions, especially the increase of the relative number of low energy photons outside the field.

43 PARTICLE ACCELERATORS↗

MO-FG-303-06: Evaluation of the Performance of Very High-Energy Electron (VHEE) Beams in Radiotherapy: Five Clinical Cases

Purpose: To evaluate the performance of 100–120 MeV very-high energy electron (VHEE) scanning pencil beams to radiotherapy by means of Monte Carlo (MC) simulations. Methods: We selected five clinical cases with target sizes of 1.2 cm{sup 3} to 990.4 cm{sup 3}. We calculated VHEE treatment plans using the MC EGSnrc code implemented in a MATLAB-based graphical user interface developed by our group. We generated phase space data for beam energies: 100 and 120 MeV and pencil beam spot sizes of 1, 3, and 5 mm at FWHM. The number of equidistant beams considered in this work was 16 or 32. Dose was calculated and then imported into a research version of RayStation where treatment plan optimization was performed. We compared the VHEE plans with the clinically delivered volumetric modulated arc therapy (VMAT) plan to evaluate VHEE plans performance. Results: VHEE plans provided the same PTV coverage and dose homogeneity than VMAT plans for all the cases. In average, the mean dose to organs at risk (OARs) was 24% lower for the VHEE plans. The structures that benefited the most from using VHEE were: large bowel for the esophagus case, chest wall for the liver case, brainstem for the acoustic case, carina for the lung case, and genitalia for the anal case, with 23.7–34.6% lower dose. VHEE dose distributions were more conformal than VMAT solution as confirmed by conformity indices CI100 and CI50. Integral dose to the body was in average 19.6% (9.2%–36.5%) lower for the VHEE plans. Conclusion: We have shown that VHEE plans resulted in similar or superior dose distributions compared to clinical VMAT plans for five different cases and a wide range of target volumes, including a case with a small target (1.2 cm{sup 3}), which represents a challenge for VMAT planning and might require the use of more complex non-coplanar VMAT plans. B Palma: None. M Bazalova: None. B Hardemark: Employee, RaySearch Laboratories AB. E Hynning: Employee, RaySearch Laboratories AB. B Qu: None. B Loo Jr.: Research support, RaySearch, Varian. P Maxim: Research support, RaySearch, Varian.

60 APPLIED LIFE SCIENCES↗

Absolute Dosimetry Model of the University of Washington Clinical Neutron Therapy System (CNTS)

The University of Washington (UW) Clinical Neutron Therapy System (CNTS) generates a fast neutron beam using 50.5 MeV protons incident on a beryllium target. The CNTS is mainly used for fast neutron therapy in the treatment of cancer but is also used for radiation effects testing and the production of rare isotopes, or isotopes with a short half-life, for medical imaging and therapy. The accelerator and treatment head is modeled using the MCNP6 Monte Carlo code to enable beam characterization (neutron and photon fluence, linear energy transfer, secondary particle production), study the behavior of neutron dosimeters and ionization chamber (IC) responses, and to conduct first principle studies of the relative biological effectiveness (RBE) of fast neutrons compared to {sup 60}Co γ-rays. Measurements of neutron dose in selected CNTS fields were made using a model-17 ion chamber (IC-17) flowing methane-based, tissue-equivalent (TE) gas. As a first approximation, we compared IC-17 measurements to the MCNP calculated dose in a thin layer of water at selected locations along the central axis of the beam. To examine the impact of the composition of the chamber fill-gas and the chamber design characteristics, we also developed a high-resolution (∼ 50 μm) MCNP model of the IC-17 from a computerized tomography (CT) scan. Initial results indicate that the dose response of the IC-17 ion chamber is up to 30% larger (smaller?) compared to the dose to water for neutrons with energies >20 MeV. Differences in chamber and water response as large as 800% occur for neutrons with kinetic energies below 1 keV. The simulations of IC-17 response (and dose to water) for CNTS fast neutron spectra match measured doses within 4.6% for all field sizes and irradiation geometries considered. This reported studies provide additional evidence establishing use of the IC-17 ion chamber model or a thin layer of water as a reasonable surrogate for CNTS fast neutron dose calculations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Model-Based Radiation Dose Correction for Yttrium-90 Microsphere Treatment of Liver Tumors With Central Necrosis

Purpose: The objectives of this study were to model and calculate the absorbed fraction {phi} of energy emitted from yttrium-90 ({sup 90}Y) microsphere treatment of necrotic liver tumors. Methods and Materials: The tumor necrosis model was proposed for the calculation of {phi} over the spherical shell region. Two approaches, the semianalytic method and the probabilistic method, were adopted. In the former method, the range--energy relationship and the sampling of electron paths were applied to calculate the energy deposition within the target region, using the straight-ahead and continuous-slowing-down approximation (CSDA) method. In the latter method, the Monte Carlo PENELOPE code was used to verify results from the first method. Results: The fraction of energy, {phi}, absorbed from {sup 90}Y by 1-cm thickness of tumor shell from microsphere distribution by CSDA with complete beta spectrum was 0.832 {+-} 0.001 and 0.833 {+-} 0.001 for smaller (r{sub T} = 5 cm) and larger (r{sub T} = 10 cm) tumors (where r is the radii of the tumor [T] and necrosis [N]). The fraction absorbed depended mainly on the thickness of the tumor necrosis configuration, rather than on tumor necrosis size. The maximal absorbed fraction {phi} that occurred in tumors without central necrosis for each size of tumor was different: 0.950 {+-} 0.000, and 0.975 {+-} 0.000 for smaller (r{sub T} = 5 cm) and larger (r{sub T} = 10 cm) tumors, respectively (p < 0.0001). Conclusions: The tumor necrosis model was developed for dose calculation of {sup 90}Y microsphere treatment of hepatic tumors with central necrosis. With this model, important information is provided regarding the absorbed fraction applicable to clinical {sup 90}Y microsphere treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detector density and small field dosimetry: Integral versus point dose measurement schemes

Purpose: TheAlfonso et al. [Med. Phys.35, 5179–5186 (2008)] formalism for small field dosimetry proposes a set of correction factors (k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}}) which account for differences between the detector response in nonstandard (clinical) and machine-specific-reference fields. In this study, the Monte Carlo method was used to investigate the viability of such small field correction factors for four different detectors irradiated under a variety of conditions. Because k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} values for single detector position measurements are influenced by several factors, a new theoretical formalism for integrated-detector-position [dose area product (DAP)] measurements is also presented and was tested using Monte Carlo simulations. Methods: A BEAMnrc linac model was built and validated for a Varian Clinac iX accelerator. Using the egs++ geometry package, detailed virtual models were built for four different detectors: a PTW 60012 unshielded diode, a PTW 60003 Diamond detector, a PTW 31006 PinPoint (ionization chamber), and a PTW 31018 MicroLion (liquid-filled ionization chamber). The egs-chamber code was used to investigate the variation ofk{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} with detector type, detector construction, field size, off-axis position, and the azimuthal angle between the detector and beam axis. Simulations were also used to consider the DAP obtained by each detector: virtual detectors and water voxels were scanned through high resolution grids of positions extending far beyond the boundaries of the fields under consideration. Results: For each detector, the correction factor (k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}}) was shown to depend strongly on detector off-axis position and detector azimuthal angle in addition to field size. In line with previous studies, substantial interdetector variation was also observed. However, it was demonstrated that by considering DAPs rather than single-detector-position dose measurements the high level of interdetector variation could be eliminated. Under small field conditions, mass density was found to be the principal determinant of water equivalence. Additionally, the mass densities of components outside the sensitive volumes were found to influence the detector response. Conclusions: k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} values for existing detector designs depend on a host of variables and their calculation typically relies on the use of time-intensive Monte Carlo methods. Future moves toward density-compensated detector designs or DAP based protocols may simplify the methodology of small field dosimetry.

07 ISOTOPE AND RADIATION SOURCES↗

Theoretical Investigation of Microstructure Evolution and Deformation of Zirconium Under Cascade Damage Conditions

This work is based on our reaction-diffusion model of radiation growth of Zr-based materials proposed recently in "On the Origin of Radiation Growth of HCP Crystals". In "On the Origin of Radiation Growth of HCP Crystals", the equations for the strain rates in unloaded pure crystal under cascade damage conditions of, e.g., neutron or heavy-ion irradiation were derived as functions of dislocation densities, which include contributions from dislocation loops, and spatial distribution of their Burgers vectors. The model takes into account the intra-cascade clustering of self-interstitial atoms and their one-dimensional diffusion; explains the growth stages, including the break-away growth of pre-annealed samples; and accounts for some striking observations, such as of negative strain in prismatic direction, and co-existence of vacancy- and interstitial-type prismatic loops. In this report, the change of dislocation densities due to accumulation of sessile dislocation loops is taken into account explicitly to investigate the dose dependence of radiation growth. The dose dependence of climb rates of dislocations is calculated, which is important for the climb-induced glide model of radiation creep. The results of fitting the model to available experimental data and some numerical calculations of the strain behavior of Zr for different initial dislocation structures are presented and discussed. The computer code RIMD-ZR.V1 (Radiation Induced Microstructure and Deformation of Zr) developed is described and attached to this report.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-T-107: An Investigation Into Attenuation Effects On the Energy Spectrum for {sup 137}Cs Using Monte Carlo Techniques

Purpose: The calibration of radiation protection instrumentation including ionization chambers, scintillators, and Geiger Mueller (GM) counters used as survey meters are often done using {sup 137}Cs irradiators. During calibration, irradiators use a combination of attenuators with various thicknesses to modulate the beam to a known air-kerma rate. The variations in energy spectra as a result of these attenuators are not accounted for and may play a role in the energy-dependent response of survey meters. This study uses an experimentally validated irradiator geometry modeled in the MCNP5 transport code to characterize the effects of attenuation on the energy spectrum. Methods: A Hopewell Designs G-10 {sup 137}Cs irradiator with lead attenuators of thicknesses of 0.635, 1.22, 2.22, and 4.32 cm, was used in this study. The irradiator geometry was modeled in MCNP5 and validated by comparing measured and simulated percent depth dose (PDD) and cross-field profiles. Variations in MCNP5 simulated spectra with increasing amounts of attenuation were characterized using the relative intensity of the 662 keV peak and the average energy. Results: Simulated and measured PDDs and profiles agreed within the associated uncertainty. The relative intensity of the 662 keV peak for simulated spectra normalized to the intensity of the unattenuated spectra ranged from 0.16% to 100% based on attenuation thickness. The average energy for simulated spectra for attenuators ranged from 582 keV with no attenuation to 653 keV with 5.54 cm of attenuation. Statistical uncertainty for MCNP5 simulations ranged from 0.11% to 3.69%. Conclusion: This study successfully used MCNP5 to validate a {sup 137}Cs irradiator geometry and characterize variations in energy spectra between different amounts of attenuation. Variations in the average energy of up to 12% were determined through simulations, and future work will aim to determine the effects of these differences on survey meter response and calibration.

07 ISOTOPE AND RADIATION SOURCES↗

Health Physics Research Reactor Criticality Accident Alarm System Benchmark Overview

From the countless critical experiments performed in the world during the past century, high-quality integral benchmarks experiments have been collected and gathered into the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook), managed by the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Working Group. This information preservation and dissemination effort is crucial for reactor licensing as well as criticality and radiation transport modeling validation. This summary reports on the status of a tentative benchmark addition to the ICSBEP Handbook. The proposed benchmark arises from legacy operation data of the Oak Ridge National Laboratory (ORNL) Health Physics Research Reactor (HPRR). The HPRR was a small, unmoderated, unshielded fast burst reactor that was used for research in health physics and radiobiology as well as teaching and training. As part of a comprehensive investigation of the available HPRR operation data and characteristics, different possibilities for use of the valuable results were studied. A critical experiment benchmark evaluation was performed, analyzing data coming from sub-critical and critical operation of the HPRR during operator training, steady-state irradiation of samples and before critical bursts. The results of the evaluation do not satisfy for the ICSBEP standards as the benchmark relative standard uncertainty is of about 4% for k eff , and the relative difference between sample calculations and expected k eff results is of about 1.5%. Due to those unsatisfactory results, it was decided not to pursue critical experiments evaluation of the HPRR presently and to focus instead on shielding type data for the creation of a criticality accident alarm system (CAAS) and shielding category benchmark, which is currently very scarce in the ICSBEP handbook—especially concerning critical, pulsed assembly, or reactor operation data. Several dosimetry and shielding experiments from HPRR burst operation were evaluated, with different benchmark metrics as sulfur fluence, Element 57 dose, or neutron fluence at different distances and under different shield materials conditions. An evaluation focusing on the Element 57 neutron dose as a benchmark metric was submitted to the ICSBEP Technical Review Group (TRG) meeting in October 2021, and the inclusion of the evaluation in the ICSBEP Handbook was deferred. The main change proposed by the international experiment evaluation experts is to use the neutron fluence measured by Bonner spheres as a benchmark metric. This represents a quantity closer to that actually measured by the experimentalists of the HPRR compared to the Element 57 dose, which adds another step of data transformation, thus potentially adding uncertainty to the benchmark. The evaluation has been updated and will be submitted to the 2022 ICSBEP TRG meeting for inclusion in the 2023 edition of the ICSBEP Handbook. The evaluation is performed using the KENO and MAVRIC combination from the SCALE 6.2.4 code suite which was previously used in similar CAAS benchmarks to allow for the use of variance reduction techniques.

61 RADIATION PROTECTION AND DOSIMETRY↗

User Guide for the Air Force Nuclear Weapons Center Dust Cloud Calculator V.1.0

The Air Force Nuclear Weapons Center (AFNWC) Dust Cloud Calculator is a Java™ application that can calculate the dust loading and radiation dose for an aircraft or cruise missile flying through a dust cloud created by a nuclear detonation. The dust cloud model is based upon the Air Force Institute of Technology (AFIT) dust cloud and fallout model. The AFIT model uses a combination of algorithms from the Weapons System Evaluation Group (WSEG) model 10 fallout code, the Defense Land Fallout Interpretive Code (DELFIC), and algorithms developed at AFIT to calculate the nuclear dust cloud.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

2010 Criticality Accident Alarm System Benchmark Experiment at the CEA Valduc SILENE Facility

Several experiments were performed at the CEA Valduc SILENE reactor facility, which are intended to be published as evaluated benchmark experiments in the ICSBEP Handbook. These evaluated benchmarks will be useful for the verification and validation of radiation transport codes and evaluated nuclear data, particularly those that are used in the analysis of CAASs. During these experiments SILENE was operated in pulsed mode in order to be representative of a criticality accident, which is rare among shielding benchmarks. Measurements of the neutron flux were made with neutron activation foils and measurements of photon doses were made with TLDs. Also unique to these experiments was the presence of several detectors used in actual CAASs, which allowed for the observation of their behavior during an actual critical pulse. This paper presents the preliminary measurement data currently available from these experiments. Also presented are comparisons of preliminary computational results with Scale and TRIPOLI-4 to the preliminary measurement data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Legislative and Regulatory Histories Related to Greater-Than-Class-C Low-Level Radioactive Waste - 18602

The history surrounding the legislative and regulatory developments regarding Greater-Than-Class C Low Level Radioactive Waste (GTCC LLW) is both interesting and complex. On October 25, 1978, the U.S. Nuclear Regulatory Commission (NRC) published an Advanced Notice of Proposed Rulemaking pertaining to the development of regulations for the land disposal of LLW. This regulation was one of the first undertaken by NRC since its inception pursuant to the Energy Reorganization Act of 1974. Given the problematic challenges that many States were facing with releases of radioactivity from waste disposal facilities at the time, the technical bases supporting this rulemaking were both forward-thinking and comprehensive. The rule included a waste classification system that was tiered in four waste classes: Class A, B, C and GTCC LLW. On December 27, 1982, the NRC finalized the requirements for disposing of these classes of radioactive waste in Title 10 of the Code of Federal Regulations, Part 61 (10 CFR 61). The NRC established the waste classification system to protect both members of the public and individuals that may someday inadvertently intrude in the waste placed in the disposal facility after expiration of the institutional control period. This waste classification was developed to ensure that radiation doses to members of the public and an inadvertent intruder would not exceed 0.25 mSv y{sup -1} (25 mrem y{sup -1}) or 5.0 mSv y{sup -1} (500 mrem y{sup -1}), respectively. At the time the regulation was promulgated, GTCC LLW was considered generally not suitable for near surface disposal. It was recognized that disposal of GTCC LLW would require disposal technologies having greater confinement capacity or protection than 'normal' near-surface disposal. In 1980 Congress enacted the Low-Level Waste Policy Act of 1980, as amended in 1985 (LLWPAA of 1985) that assigned responsibility of disposing of GTCC LLW generated in the commercial sector or owned or generated by the federal government to the U.S. Department of Energy (DOE). At the time States were having difficulties in developing disposal facilities within the time constraints mandated in the LLWPA of 1980. Therefore, Congress believed that if DOE was assigned responsibility of developing disposal facilities for GTCC LLW, then the States would be more likely to develop new LLW disposal facilities. Congress also assigned the NRC with the responsibility to license the disposal of GTCC LLW generated or owned by the federal government or by the commercial sector. Lastly, Congress changed the definition of LLW that had been defined in the LLWPA of 1980 removing the 'transuranic' exclusionary language. Four years later, on May 25, 1989, the NRC promulgated its regulation needed to implement the mandates specified in the LLWPAA of 1985. The NRC revised 10 CFR 61.55 specifying that the NRC was responsible for licensing the disposal of GTCC LLW. However, it inadvertently did not revise the definition of LLW needed to remove the 'transuranic' exclusionary language in this rulemaking consistent with the LLWPAA of 1985. This seemingly inconsequential omission was not discovered until a Petition for Rulemaking was filed in Texas in July 2014. Moreover, this omission has effectively orphaned waste with certain transuranic radionuclides with concentrations exceeding 100 nanocuries per gram (100 nCi/g). In December 2015, the NRC Commissioners directed its staff to move forward with a rulemaking to resolve this issue and to perform a regulatory analysis to determine whether or not an Agreement State can license the disposal of GTCC LLW pursuant to Section 274 of the Atomic Energy Act of 1954. The paper will discuss past and current legislation, rulemaking, and regulatory developments pertaining to resolving the transuranic waste discrepancy and providing a pathway to disposition GTCC LLW. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of a Conditioned System-Level Groundwater Model to Evaluate Long-Term Groundwater Impacts within a Performance Assessment - 20115

A preliminary performance assessment (PA) of single-shell tank Waste Management Area (WMA) A-AX located at the U.S. Department of Energy (DOE)'s Hanford Site in southeastern Washington is being conducted to satisfy the requirements of DOE Order 435.1 [1] as it relates to closure of the single-shell radioactive waste tanks in the WMA A-AX tank farms. A PA assesses the fate, transport, and impacts of radionuclides within a low-level radioactive waste disposal facility in its assumed closure configuration and the subsequent potential doses to humans over a 1,000-year compliance period and a 10,000-year performance evaluation period. The WMA A-AX preliminary PA evaluation is structured around the complementary use of process-level and system-level models to calculate the facility performance against established DOE Order 435.1 [1] performance objectives. Process-level models are those that represent a detailed phenomenological representation of processes of concern in the PA. Process models typically only represent one or a few of the components of the PA, such as groundwater flow and transport, and must be integrated with other modeling elements to perform PA calculations. System-level models are those that are abstracted from the process models, retaining the essential features of the process model, while allowing integration of all aspects of the PA in a single modeling framework. System-level models are often characterized by coarser numerical discretization, lower dimensionality, or other similar simplifications compared to the process-level model. Traditionally, a three-dimensional (3-D) process-level model is utilized primarily to evaluate the long-term impact on groundwater and the potential doses to individuals who consume contaminated groundwater. System-level models are also utilized to evaluate the groundwater pathway in PAs. These models typically have reduced dimensionality (1-D) and are conditioned utilizing flow fields (Darcy fluxes) and moisture content distributions that are abstracted from the process level models. The abstraction approach assures that the flow field in both models is consistent for a specific set of input parameters for flow, differing only in the discretization and dimensionality of the two models. The preliminary WMA A-AX PA incorporates a detailed representation of the geological system and hydraulic properties within the 3-D model STOMP{sup C} numerical code so that the effects of relevant features and processes on water flow and radionuclide transport in the subsurface can be evaluated. The complementary system-level model is developed utilizing the GoldSim{sup C} code to implement a simplified, 1-D equivalent model to represent the groundwater pathway. Contaminant transport through the vadose zone and unconfined aquifer for Tc-99 and I-129 were evaluated in each of the models. Adjustments to the saturated portion of the GoldSim{sup C} 1-D model were required to mimic the dispersion effect captured with the 3-D STOMP{sup C} model. Once this conditioning was conducted, highly similar results for the transport of Tc-99 and I-129 were achieved at the point of calculation, located 100 m downgradient from the WMA A-AX fenceline. These radionuclides represent elements that are regarded as primary dose drivers in the PA groundwater pathway analysis. The high degree of conformance between the two models suggests that the use of the equivalent 1-D system model is suitable for evaluating the full suite of radionuclides that will be released from the tank sources within WMA A-AX over the 1,000-year compliance period and over the 10,000-year evaluation period. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimization of a Mu2e production solenoid heat and radiation shield using MARS15

A Monte-Carlo study of several Mu2e Production Solenoid (PS) absorber (heat shield) versions using the MARS15 code has been performed. Optimizations for material as well as cost (amount of tungsten) have been carried out. Studied are such quantities as the number of displacements per atom (DPA) in the helium-cooled solenoid superconducting coils, power density and dynamic heat load in various parts of the PS and its surrounding structures. Prompt dose, residual dose, secondary particle flux are also simulated in the PS structures and the experimental hall. A preliminary choice of the PS absorber design is made on the ground of these studies.

43 PARTICLE ACCELERATORS↗

Occupational Radiation Exposure Report for Calendar Year 2023

The U.S. Department of Energy Occupational Radiation Exposure Report for Calendar 2023 presents the results of analyses of occupational radiation exposures at the U.S. Department of Energy (DOE), including the National Nuclear Security Administration (NNSA) operations, during calendar year 2023. This report includes occupational radiation exposure data for over 80,000 DOE Federal employees, contractors, and subcontractors as well as members of the public who have worked in or entered controlled areas monitored for exposure to radiation. DOE publishes this annual report to provide DOE Management, Program Offices, workers, health physicists, and other stakeholders an evaluation of DOE-wide performance regarding compliance with Title 10 of the Code of Federal Regulations (CFR) Part 835, Occupational Radiation Protection (10 CFR 835) radiation exposure limits and adherence to as low as reasonably achievable principles. This report provides a discussion regarding radiation protection and exposure reporting requirements. It also includes calendar year (CY) 2023 information and analyses regarding aggregate, individual, site, DOE Program, transient individuals’ dose, as well as a historical review of DOE exposure data. DOE continues to be diligent in protecting its workers and the public from exposure to radiation from DOE operations as illustrated by the results contained in this report.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗