Development of PET/MRI with insertable PET for simultaneous PET and MR imaging of human brain

Purpose: The purpose of this study was to develop a dual-modality positron emission tomography (PET)/magnetic resonance imaging (MRI) with insertable PET for simultaneous PET and MR imaging of the human brain. Methods: The PET detector block was composed of a 4 × 4 matrix of detector modules, each consisting of a 4 × 4 array LYSO coupled to a 4 × 4 Geiger-mode avalanche photodiode (GAPD) array. The PET insert consisted of 18 detector blocks, circularly mounted on a custom-made plastic base to form a ring with an inner diameter of 390 mm and axial length of 60 mm. The PET gantry was shielded with gold-plated conductive fabric tapes with a thickness of 0.1 mm. The charge signals of PET detector transferred via 4 m long flat cables were fed into the position decoder circuit. The flat cables were shielded with a mesh-type aluminum sheet with a thickness of 0.24 mm. The position decoder circuit and field programmable gate array-embedded DAQ modules were enclosed in an aluminum box with a thickness of 10 mm and located at the rear of the MR bore inside the MRI room. A 3-T human MRI system with a Larmor frequency of 123.7 MHz and inner bore diameter of 60 cm was used as the PET/MRI hybrid system. A custom-made radio frequency (RF) coil with an inner diameter of 25 cm was fabricated. The PET was positioned between gradient and the RF coils. PET performance was measured outside and inside the MRI scanner using echo planar imaging, spin echo, turbo spin echo, and gradient echo sequences. MRI performance was also evaluated with and without the PET insert. The stability of the newly developed PET insert was evaluated and simultaneous PET and MR images of a brain phantom were acquired. Results: No significant degradation of the PET performance caused by MR was observed when the PET was operated using various MR imaging sequences. The signal-to-noise ratio of MR images was slightly degraded due to the PET insert installed inside the MR bore while the homogeneity was maintained. The change of gain of the 256 GAPD/scintillator elements of a detector block was <3% for 60 min, and simultaneous PET and MR images of a brain phantom were successfully acquired. Conclusions: Experimental results indicate that a compact and lightweight PET insert for hybrid PET/MRI can be developed using GAPD arrays and charge signal transmission method proposed in this study without significant interference.

60 APPLIED LIFE SCIENCES↗

History-dependent dissipative vortex dynamics in superconducting arrays

In this study, we perform current (I)-voltage (V) measurements on low resistance superconductor-normal-superconductor arrays in finite magnetic fields, focusing on the dilute vortex population regime. We observe significant deviations from predicted behavior, notably the absence of a differential resistance peak near the vortex depinning current, and a broad linear I-V region with an extrapolated I intercept equal to the depinning current. Comparing these results to an overdamped molecular vortex model, we find that this behavior can be explained by the presence of a history-dependent dissipative force. Lastly, this approach has not been considered previously, to our knowledge, yet it is crucial for obtaining a correct description of the vortex dynamics in superconducting arrays.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Broken symmetry dielectric resonators for high quality factor Fano metasurfaces

We present a new approach to dielectric metasurface design that relies on a single resonator per unit cell and produces robust, high quality factor Fano resonances. Our approach utilizes symmetry breaking of highly symmetric resonator geometries, such as cubes, to induce couplings between the otherwise orthogonal resonator modes. In particular, we design perturbations that couple “bright” dipole modes to “dark” dipole modes whose radiative decay is suppressed by local field effects in the array. Our approach is widely scalable from the near-infrared to radio frequencies. We first unravel the Fano resonance behavior through numerical simulations of a germanium resonator-based metasurface that achieves a quality factor of ~1300 at ~10.8 μm. Then, we present two experimental demonstrations operating in the near-infrared (~1 μm): a silicon-based implementation that achieves a quality factor of ~350; and a gallium arsenide-based structure that achieves a quality factor of ~600, the highest near-infrared quality factor experimentally demonstrated to date with this kind of metasurface. Importantly, large electromagnetic field enhancements appear within the resonators at the Fano resonant frequencies. Here, we envision that combining high quality factor, high field enhancement resonances with nonlinear and active/gain materials such as gallium arsenide will lead to new classes of active optical devices.

36 MATERIALS SCIENCE↗

Two-color beam improvement of the colloidal particle lens array assisted surface nanostructuring

We consider laser nanostructuring of the material surface by means of a colloidal particle lens array. Here, the monolayer of dielectric micro- or nanospheres placed on the surface acts as an array of near-field lenses that focus the laser radiation into the multitude of distinct spots, allowing the formation of many structures in a single stage. We show that conversion of a small part of the energy of the femtosecond beam into the second harmonic (SH) is an efficient way to increase the surface density of obtained nanostructures. By combining the fundamental frequency and the SH, one benefits both from the power of the former and from the focusing ability of the latter. This combination provides an efficient nanostructuring with sphere diameter close to the wavelength of the second harmonic. The possibility to create arrays of nanostructures with surface density above 5×10{sup 8} cm{sup −2} with femtosecond Ti:sapphire laser operating at 800 nm was demonstrated by employing 0.45 μm spheres.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Source Identification and Location Techniques

Mr. Weir presented source location results obtained from an engine test as part of the Engine Validation of Noise Reduction Concepts program. Two types of microphone arrays were used in this program to determine the jet noise source distribution for the exhaust from a 4.3 bypass ratio turbofan engine. One was a linear array of 16 microphones located on a 25 ft. sideline and the other was a 103 microphone 3-D "cage" array in the near field of the jet. Data were obtained from a baseline nozzle and from numerous nozzle configuration using chevrons and/or tabs to reduce the jet noise. Mr. Weir presented data from two configurations: the baseline nozzle and a nozzle configuration with chevrons on both the core and bypass nozzles. This chevron configuration had achieved a jet noise reduction of 4 EPNdB in small scale tests conducted at the Glenn Research Center. IR imaging showed that the chevrons produced significant improvements in mixing and greatly reduced the length of the jet potential core. Comparison of source location data from the 1-D phased array showed a shift of the noise sources towards the nozzle and clear reductions of the sources due to the noise reduction devices. Data from the 3-D array showed a single source at a frequency of 125 Hz. located several diameters downstream from the nozzle exit. At 250 and 400 Hz., multiple sources, periodically spaced, appeared to exist downstream of the nozzle. The trend of source location moving toward the nozzle exit with increasing frequency was also observed. The 3-D array data also showed a reduction in source strength with the addition of chevrons. The overall trend of source location with frequency was compared for the two arrays and with classical experience. Similar trends were observed. Although overall trends with frequency and addition of suppression devices were consistent between the data from the 1-D and the 3-D arrays, a comparison of the details of the inferred source locations did show differences. A flight test is planned to determine if the hardware tested statically will achieve similar reductions in flight.

Weir, Donald↗

MAGNETIC LIQUID DEFORMABLE MIRRORS FOR ASTRONOMICAL APPLICATIONS: ACTIVE CORRECTION OF OPTICAL ABERRATIONS FROM LOWER-GRADE OPTICS AND SUPPORT SYSTEM

Deformable mirrors are increasingly used in astronomy. However, they still are limited in stroke for active correction of high-amplitude optical aberrations. Magnetic liquid deformable mirrors (MLDMs) are a new technology that has the advantages of high-amplitude deformations and low costs. In this paper, we demonstrate extremely high strokes and interactuator strokes achievable by MLDMs which can be used in astronomical instrumentation. In particular, we consider the use of such a mirror to suggest an interesting application for the next generation of large telescopes. We present a prototype 91 actuator deformable mirror made of a magnetic liquid (ferrofluid). This mirror uses a technique that linearizes the response of such mirrors by superimposing a large and uniform magnetic field on the magnetic field produced by an array of small coils. We discuss experimental results that illustrate the performance of MLDMs. A most interesting application of MLDMs comes from the fact they could be used to correct the aberrations of large and lower optical quality primary mirrors held by simple support systems. We estimate basic parameters of the needed MLDMs, obtaining reasonable values.

79 ASTRONOMY AND ASTROPHYSICS↗

Array-fed reflector antenna design and applications

One phase of the spacecraft antenna research carried out at the Jet Propulsion Laboratory for deep space and near-earth communications is described. Array-fed reflector antenna designs have been elaborated for beam scanning, power amplification, and multiple beam applications. The antenna designs derive from similar optical concepts. Each antenna comprises a relatively small plane-wave array feeding a near-field dual-reflector system. The main reflector and the the subreflector are confocal paraboloids having identical focal length to diameter ratios. The array feed is positioned in such a way that the subreflector is in the near-field (collimated beam) region of the feed. The field distribution of the feed aperture is thereby recreated approximately in the main reflector aperture. The detailed design concepts of the antennas (beam-scanning, high-power, and mutliple-beam) are discussed, and the calculated and measured RF performances of the antennas are presented.

Woo, K.↗

Electron spectrometer in adjustable triode configuration for photo-induced field emission measurements

We have constructed a new ultrahigh vacuum apparatus with a triode configuration for the systematic investigation of photo-induced field emission (PFE) from metallic or semiconducting cathodes. These are exposed to electric fields up to 400 MV/m and laser irradiation by means of hole or mesh gates. Cathodes and gates are in situ exchangeable and adjustable with high precision to ensure a homogeneous extraction of electrons which are partially transmitted to the fixed electron spectrometer. Its hemispherical sector analyzer provides an energy resolution limit of 8 meV. The commissioning of the measurement system has been performed with a tungsten needle. Its temperature showed up in the high-energy tail of the electron spectrum, while its work function was derived from the spectral low-energy part combined with the integral current-voltage curve. First PFE measurements on B-doped Si-tip arrays yielded a small field emission current increase under green laser illumination. A shift and splitting of the energy spectra was observed which revealed different emission regimes as well as the photosensitivity of the cathode due to carrier excitation into the conduction band. For the full exploitation of the PFE system, a tunable laser over a wide eV-range is required.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pressure-driven assembly of spherical nanoparticles and formation of 1D nanostructure arrays.

External pressure was used to engineer nanoparticle assembly. Reversible manipulation of the unit-cell dimensions of a 3D ordered nanoparticle array under a hydrostatic pressure field enabled the fine-tuning of the interparticle distance. Under a uniaxial pressure field, nanoparticles were forced to contact and coalesce into nanorods or nanowires and ordered ultrahigh-density arrays (see picture; small arrows denote pressure).

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Ultrasonic Phased Array Evaluation of Control Rod Drive Mechanism (CRDM) Nozzle Interference Fit and Weld Region

Ultrasonic phased array data were collected on a removed-from-service CRDM nozzle specimen to assess a previously reported leak path. First a mock-up CRDM specimen was evaluated that contained two 0.076-mm (3.0-mil) interference fit regions formed from an actual Inconel CRDM tube and two 152.4-mm (6.0-in.) thick carbon steel blocks. One interference fit region has a series of precision crafted electric discharge machining (EDM) notches at various lengths, widths, depths, and spatial separations for establishing probe sensitivity, resolution and calibration. The other interference fit has zones of boric acid (crystal form) spaced periodically between the tube and block to represent an actively leaking CRDM nozzle assembly in the field. Ultrasonic phased-array evaluations were conducted using an immersion 8-element annular 5.0-MHz probe from the tube inner diameter (ID). A variety of focal laws were employed to evaluate the interference fit regions and J grove weld, where applicable. Responses from the mock-up specimen were evaluated to determine detection limits and characterization ability as well as contrast the ultrasonic response differences with the presence of boric acid in the fit region. Nozzle 63, from the North Anna Unit-2 nuclear power plant, was evaluated to assess leakage path(s) and was destructively dismantled to allow a visual verification of the leak path(s).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Overview and first measurements of the MAST Upgrade bolometer diagnostic

Here, a suite of multi-channel resistive bolometers has been implemented to measure the total radiation from Mega Amp Spherical Tokamak Upgrade plasmas, with cameras covering the core plasma and lower divertor chamber. Data are digitized and processed using novel field-programmable gate array-based electronics, offering improved compactness and new operational capabilities. A synthetic diagnostic has been developed to explore the quality of 2D reconstructions available from the system and to quantify the uncertainty on quantities such as the total radiated power. Measurements in the first campaign have demonstrated correct functioning of the diagnostic while also highlighting issues with electrical noise and some failure mechanisms of the detectors, as well as significant neutral beam fast-particle losses.

47 OTHER INSTRUMENTATION↗

SU-E-T-219: Investigation of IMRT Out-Of-Field Dose Calculation Accuracy for a Commercial Treatment Planning System

Purpose: Inaccuracies in out-of-field calculations could lead to underestimation of dose to organs-at-risk. This study evaluates the dose calculation accuracy of a model-based calculation algorithm at points outside the primary treatment field for an intensity modulated radiation therapy (IMRT) plan using experimental measurements. Methods: The treatment planning system investigated is Varian Eclipse V.10 with Analytical Anisotropic Algorithm (AAA). The IMRT fields investigated are from real patient treatment plans. The doses from a dynamic (DMLC) IMRT brain plan were calculated and compared with measured doses at locations outside the primary treatment fields. Measurements were performed with a MatriXX system (2-D chamber array) placed in solid water. All fields were set vertically incident on the phantom and were 9 cm × 6 cm or smaller. The dose was normalized to the central axis for points up to 15 cm off isocenter. The comparisons were performed at depths of 2, 10, 15, and 20 cm Results: The measurements have shown that AAA calculations underestimate doses at points outside the primary treatment field. The underestimation occurs at 2 cm depth and decreases down to a factor of 2 as depth increases to 20 cm. In low dose (<2% of target dose) regions outside the primary fields the local dose underestimations can be >200% compared to measured doses. Relative to the plan target dose, the measured doses to points outside the field were less than 1% at shallow depths and less than 2% at greater depths. Conclusion: Compared to measurements, the AAA algorithm underestimated the dose at points outside the treatment field with the greatest differences observed at shallow depths. Despite large local dose uncertainties predicted by the treatment planning system, the impact of these uncertainties is expected to be insignificant as doses at these points were less than 1-2% of the prescribed treatment dose.

60 APPLIED LIFE SCIENCES↗

Source physics experiments at the Nevada Test Site.

The U. S. capability to monitor foreign underground nuclear test activities relies heavily on measurement of explosion phenomena, including characteristic seismic, infrasound, radionuclide, and acoustic signals. Despite recent advances in each of these fields, empirical, rather than physics-based, approaches are used to predict and explain observations. Seismologists rely on prior knowledge of the variations of teleseismic and regional seismic parameters such as p- and s-wave arrivals from simple one-dimensional models for the teleseismic case to somewhat more complicated enhanced two-dimensional models for the regional case. Likewise, radionuclide experts rely on empirical results from a handful of limited experiments to determine the radiological source terms present at the surface after an underground test. To make the next step in the advancement of the science of monitoring we need to transform these fields to enable predictive, physics-based modeling and analysis. The Nevada Test Site Source Physics Experiments (N-SPE) provide a unique opportunity to gather precise data from well-designed experiments to improve physics-based modeling capability. In the seismic experiments, data collection will include time domain reflectometry to measure explosive performance and yield, free-field accelerometers, extensive seismic arrays, and infrasound and acoustic measurements. The improved modeling capability that we will develop using this data should enable important advances in our ability to monitor worldwide for nuclear testing. The first of a series of source physics experiments will be conducted in the granite of Climax Stock at the NTS, near the locations of the HARD HAT and PILE DRIVER nuclear tests. This site not only provides a fairly homogeneous and well-documented geology, but also an opportunity to improve our understanding of how fractures, joints, and faults affect seismic wave generation and propagation. The Climax Stock experiments will consist of a 220 lb (TNT equivalent) calibration shot and a 2200 lb (TNT equivalent) over-buried shot conducted in the same emplacement hole. An identical 2200 lb shot at the same location will follow to investigate the effects of pre-conditioning. These experiments also provide an opportunity to advance capabilities for near-field monitoring, and on-site inspections (OSIs) of suspected testing sites. In particular, geologic, physical, and cultural signatures of underground testing can be evaluated using the N-SPE activities as case studies. Furthermore, experiments to measure the migration of radioactive noble gases to the surface from underground explosions will enable development of higher fidelity radiological source term models that can predict migration through a variety of geologic conditions. Because the detection of short-lived radionuclides is essential to determining if an explosion was nuclear or conventional, a better understanding of the gaseous and particulate radionuclide source terms that reach the surface from underground testing is critical to development of OSI capability.

47 OTHER INSTRUMENTATION↗

Assessment and Performance of Flexible Quench Antenna Array Diagnostics for Superconducting Magnets

FNAL has been developing multiple versions of flexible quench antennas (flex-QA), including some specially optimized for high sensitivity and/or high resolution, to characterize quench events and transients during current ramping in superconducting magnets. A fundamental feature in our use of these is the creation of grid-like structures of sensitive elements to cover coil surfaces, with the aim of getting precise localization of magnetic flux-change events. The flex-QA are coupled with fast data-acquisition, allowing comprehensive analysis of signals at the relevant fine time scales. In addition to arrays of various flex-QA types being used during cryogenic testing of superconducting magnets, we also are utilizing a newly developed room temperature test stand to better understand QA response characteristics. The data from actual superconducting magnet tests, warm test stand measurements, and simulation data on the same QA designs allows us to draw conclusions on operational feasibility and plan better for improvements of our sensors. In this paper we present data from the multiple tests performed and analysis results. Flex-QA designs are compared, and their features, options, and optimization discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Near-field-driven radiative thermal dynamics in aperiodic photonic nanostructures

Harnessing structural correlations in near-field plasmonic and polaritonic systems hold untapped potential for controlling light–matter interactions at the nanoscale. By tuning these correlations, one can reshape mode localization, coupling, and spectral distribution which are properties central to manipulating energy transport and field enhancement in nanophotonic platforms. We exploit Vogel spirals, an aperiodic geometry where a single parameter dictates spatial correlations, to show how correlation strength reshapes the modal spectrum and transient dynamics of near-field coupling. As a proof of concept, we demonstrate that aperiodic configurations outperform both uncorrelated (random) and periodic arrays in controlling near-field radiative heat-transfer dynamics. These results establish deterministic aperiodic order as a powerful platform for tailoring correlated electromagnetic responses in next-generation nanophotonic devices.

36 MATERIALS SCIENCE↗

DARHT-II Beam Position Monitor B-Dot Owner’s Manual

Azimuthal arrays of magnetic and electric field detectors are used to measure the position of the centroid of the DARHT relativistic electron beams. These arrays consist of four detectors with 90-degree azimuthal separation. Differencing the opposing detectors and normalizing to the sum of all four gives the position of the beam, subject to negligibly small errors as discussed in Attachment A. This measurement yields the centroid of the current density, independent of the beam azimuthal asymmetry.

42 ENGINEERING↗

Automated inspection of surface breaking cracks using GMR sensor arrays

We present a prototype for automated magnetic stray field testing of ferromagnetic roller bearings. For this purpose NDE-adapted GMR sensor arrays (giant magneto resistance) are used for the detection of surface breaking cracks. The sensors are miniaturized down to the lower μm-regime to achieve adequate spatial resolution. In doing so, sensor arrays with up to 48 elements are used to inspect the bearing surface within a few seconds only. In contrast to magnetic particle inspection (MPI), where the global magnetization requires a further inspection step and succeeding demagnetization, the presented prototype only locally magnetize the surface area in the vicinity of the GMR Sensors. For the local magnetization, the applied sub-surface magnetic field was simulated and proofed for detecting flaws with a depth of a few 10 μm. By multiplexing the sensor array with an adapted read out electronics we quasi simultaneously detect the normal field component of about 100μm above the surface. The detection of artificial notches with a depth of 40 μm and more could be resolved with a SNR better than 20 dB. The presented testing facility is fast and provides a step towards automated testing of safety relevant steel components.