Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fluids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Metastable Fluid Decay During Electric Explosion of Metallic Foils

Results of experimental investigations into overheated metastable fluid decay during electric explosion of metallic foils are presented. Experiments have been performed using an experimental complex consisting of three current generators, one of which provides explosion of foil and two others – X-pinch-based radiographs – are used for diagnostic purposes. The upper limit of the decay time of an overheated metastable metal is determined experimentally. For aluminum conductor with deposited energy of (5.3 ± 0.5) kJ/g, the metastable state decay time is ~110 ns; for copper foil with deposited energy of (2.4 ± 0.2) kJ/g, it is ~260 ns; and for nickel foil with deposited energy of (1.3 ± 0.3) kJ/g, it is ~350 ns.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Approach to Cerebrospinal Fluid (CSF) Biomarker Discovery and Evaluation in HIV Infection

Central nervous system (CNS) infection is a nearly universal facet of systemic HIV infection that varies in character and neurological consequences. While clinical staging and neuropsychological test performance have been helpful in evaluating patients, cerebrospinal fluid (CSF) biomarkers present a valuable and objective approach to more accurate diagnosis, assessment of treatment effects and understanding of evolving pathobiology. We review some lessons from our recent experience with CSF biomarker studies. We have used two approaches to biomarker analysis: targeted, hypothesis-driven and non-targeted exploratory discovery methods. We illustrate the first with data from a cross-sectional study of defined subject groups across the spectrum of systemic and CNS disease progression and the second with a longitudinal study of the CSF proteome in subjects initiating antiretroviral treatment. Both approaches can be useful and, indeed, complementary. The first is helpful in assessing known or hypothesized biomarkers while the second can identify novel biomarkers and point to broad interactions in pathogenesis. Common to both is the need for well-defined samples and subjects that span a spectrum of biological activity and biomarker concentrations. Previouslydefined guide biomarkers of CNS infection, inflammation and neural injury are useful in categorizing samples for analysis and providing critical biological context for biomarker discovery studies. CSF biomarkers represent an underutilized but valuable approach to understanding the interactions of HIV and the CNS and to more objective diagnosis and assessment of disease activity. Both hypothesis-based and discovery methods can be useful in advancing the definition and use of these biomarkers.

Biomarkers↗

Effects of Heat Treatment on Corrosion and Wear Behaviors of Mg-6Gd-2Zn-0.4Zr Alloy in Simulated Body Fluid

Mg-6Gd-2Zn-0.4Zr (wt.%, GZ62K) alloy was processed by solution treatment under different temperatures. The microstructure, hardness, corrosion and wear behaviors in simulated body fluid (SBF) have been studied. The results indicate that the (Mg, Zn){sub 3}Gd phase decreases, the precipitated phases gradually increase, and the long-period stacking ordered structure disappears with the increase of solution temperature. The alloy has better corrosion resistance after solution treatment, and that solution treated at 490 °C for 12 h shows the best corrosion resistance. The friction coefficient of the alloy under dry sliding condition decreases slightly, but the mass loss increases with increasing the solution temperature. The alloy solution treated at 460 °C for 12 h exhibits the lowest friction coefficient and mass loss in SBF, and it also has the best wear resistance under dry sliding condition.

36 MATERIALS SCIENCE↗

Electrochemical Corrosion and In vitro Biocompatibility Performance of AZ31Mg/Al{sub 2}O{sub 3} Nanocomposite in Simulated Body Fluid

In this present investigation, AZ31 alloy nanocomposite was prepared with the inclusion of Al{sub 2}O{sub 3} nanoparticles using innovative disintegrated melt deposition (DMD) process followed by hot extrusion to improve the corrosion resistance and in vitro biocompatibility in simulated body fluid (SBF). This investigation systematically inspected the degradation performances of AZ31 alloy with Al{sub 2}O{sub 3} nanoparticles through hydrogen evolution, weight loss and electrochemical methods in SBF. Further, the surface microstructure with the in vitro mineralization of the alloys in SBF was characterized by XRD, XPS, and SEM/EDS analysis. It was seen that the addition of Al{sub 2}O{sub 3} nanoparticles significantly decreased the weight loss of AZ31 alloy substrates after 336 h of exposure in SBF. The corrosion resistance of the monolithic and nanocomposite samples was evaluated using potentiodynamic polarization tests, electrochemical impedance spectroscopy measurements in short- and long-term periods. Accordingly, the electrochemical analysis in SBF showed that the corrosion resistance performance of the AZ31 alloy enhanced considerably due to the incorporation of Al{sub 2}O{sub 3} nanoparticles as reinforcement. Moreover, the rapid formation of bone-like apatite layer on the surface of the nanocomposite substrate demonstrated a good bioactivity of the nanocomposite samples in SBF.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Fabrication of Brushite Coating on AZ91D and AZ31 Alloys by Two-Step Chemical Treatment and Its Surface Protection in Simulated Body Fluid

A biocompatible dicalcium phosphate dihydrate (DCPD) brushite coating of flake-like crystals was developed on AZ91D and AZ31 magnesium (Mg) surfaces to control and slow down the rapid degradation rate of the substrates. The electrochemical behavior of the DCPD-coated substrates was examined in a simulated body fluid (SBF) with uncoated substrates as the control. Fabrication of the coating was achieved via chemical immersion technique by modifying the surfaces with Ca(NO{sub 3}){sub 2}·4H{sub 2}O and KH{sub 2}PO{sub 4} in addition to heat treatment. The morphology of the DCPD coating is uniform and dense with a flake-like crystal structure. After in vitro tests, the DCPD coating would have exhibited excellent corrosion resistance with more biomineralization of the active calcium phosphate (CaP). Moreover, the DCPD coating induced CaP formation after immersion in the SBF, indicating excellent bioactivity upon increasing the coating. Hence, the two-step chemical treatment enhances the bioactivity of DCPD coatings on Mg alloys, making them better implant materials.

36 MATERIALS SCIENCE↗

Improved Electrochemical Performance of Plasma Electrolytic Oxidation Coating on Titanium in Simulated Body Fluid

The effect of plasma electrolytic oxidation (PEO) pre-treatments on corrosion behavior of titanium in simulated body fluid (SBF) is investigated. Three pre-treatments are compared, using silicate, calcium phosphate and mixed silicate and calcium phosphate (1:1) electrolytes, respectively. The resultant coatings in different compositions and morphologies were examined by high-resolution field emission scanning electron microscopy equipped with energy-dispersive spectrometer and x-ray diffraction. The PEO-treated specimens revealed distribution of coating species, mainly the titanium-rich inner coating region. However, findings show highly localized variations in composition within their crystalline structures, due to the melting and rapid solidification of the coating material in three different electrolytes. Corrosion behavior of the coatings was also examined in SBF at 37 °C by potentiodynamic polarization, revealing an improvement in corrosion resistance for mixed electrolyte compared to silicate and calcium phosphate electrolytes.

36 MATERIALS SCIENCE↗

Correlation between Antimicrobial Activity and Bioactivity of Na-Mica and Na-Mica/Fluorapatite Glass and Glass-Ceramics and Their Corrosion Protection of Titanium in Simulated Body Fluid

The improvement in bioactivity of titanium (Ti) surface was achieved via coating it with Na-mica and Na-mica/fluorapatite glass and glass-ceramic using the low-cost electrophoretic deposition technique. Two compositions from pure Na-mica (M) and 80 Na-mica/20 fluorapatite glasses (MF) were prepared in the system SiO{sub 2}-Al{sub 2}O{sub 3}-MgO-MgF{sub 2}-Na{sub 2}O-B{sub 2}O{sub 3} using melting–quenching technique. Characterization of the as-prepared glasses and their counterpart glass-ceramics was studied using differential thermal analysis (DTA), x-ray diffraction (XRD), Scanning Electron Microscopy (SEM) and Fourier Transform-IR (FTIR) spectroscopy techniques. The bioactivity behavior was proved by studying the XRD, FTIR and SEM after immersing both glass and glass-ceramic samples in simulated body fluid (SBF). Both M and MF glasses and glass-ceramics showed high microhardness measurements and good antibacterial behavior. In vitro biodegradation was studied by using electrochemical corrosion behavior of the prepared glass- and glass-ceramic-coated Ti in SBF. The prepared coated Ti showed good corrosion resistance in SBF at 37 °C using potentiodynamic polarization technique, and the impedance data fitting explained the structure of the coating and the adsorption of SBF ions on the Ti surface. The MFGC provides the best corrosion-resistant coating, especially after sintering it.

36 MATERIALS SCIENCE↗

Semi-numerical solution to a fractal telegraphic dual-porosity fluid flow model

We present a semi-numerical solution to a fractal telegraphic dual-porosity fluid flow model. It combines Laplace transform and finite difference schemes. The Laplace transform handles the time variable whereas the finite difference method deals with the spatial coordinate. This semi-numerical scheme is not restricted by space discretization and allows the computation of a solution at any time without compromising numerical stability or the mass conservation principle. Our formulation results in a non-analytically-solvable second-order differential equation whose spatial discretization yields a tridiagonal linear algebraic system. Moreover, we describe comparisons between semi-numerical and semi-analytical solutions for particular cases. Results agree well with those from semi-analytic solutions. Furthermore, we expose a parametric analysis from the coupled model in order to show the effects of relevant parameters on pressure profiles and flow rates for the case where neither analytic nor semi-analytic solutions are available.

97 MATHEMATICS AND COMPUTING↗

Methodology for Thermodynamic Analysis Coupled with Computational Fluid Dynamics Modeling for Casting a Novel Aluminum–Cerium Alloy

In this paper, we present the results of computational fluid dynamics (CFD) analysis to assess castability, porosity, molten metal fluidity and other technological properties of a new Al-Ce alloy. A thermodynamic analysis of a new Al-Ce alloy is done to obtain the physical properties as a function of temperature across both solid and liquid phases. These properties are then used to build the CFD of model the full casting process from initial pouring through to final solidification of the part, here an example of a heavy duty mor mount is used. While several excellent commercial CFD codes exists this process shows that CFD can be used to assess the capability of the alloy to properly fill the mold, as well as give predictions where scattered porosity or large-scale defects may occur in the casting. Further, unlike the commercially available software (e.g., ProCAST, SOLIDCast , MAGMASOFT®) the complex 3D-analysis of the stress / strain fields in cast parts is not performed at this time. However, the availability of free software for assessing the required thermodynamic / thermo-physical properties of new alloys (OpenCALPHAD) and CFD codes such as OpenFOAM® makes the developed option attractive and economical, especially for the analysis of new Al-Ce alloys, for which the available data does not exist.

36 MATERIALS SCIENCE↗

Modeling of heat transfer, fluid flow and solidification microstructure of nickel-base superalloy fabricated by laser powder bed fusion

Laser-Powder Bed Fusion (L-PBF), an additive manufacturing process, produces a distinctive microstructure that closely resembles the weld metal microstructure but at a much finer scale. The solidification parameters, particularly temperature gradient and solidification rate, are important to study the as-built microstructure. In the present paper, a computational framework with meso-scale resolution is developed for L-PBF of Inconel ® 718 (IN718), a Ni-base superalloy. The framework combines a powder packing model based on Discrete Element Method and a 3-D transient heat and fluid flow simulation. The latter, i.e., the molten pool model, captures the interaction between laser beam and individual powder particles including free surface evolution, surface tension and evaporation. The solidification parameters, calculated from the temperature fields, are used to assess the solidification morphology and grain size using existing theoretical models. The IN718 coupon built by L-PBF are characterized using optical and scanning electron microscopies. Finally, the experimental data of molten pool size and solidification microstructure are compared to the corresponding simulation results.

36 MATERIALS SCIENCE↗

A Geometric Volume of Fluid-Based Multiphase Flow Solver Extension to the Reacting Flow Solver, PeleLM

A new algorithm is presented to simulate multiphase flows with surface tension in a pathway for spray combustion simulation. The algorithm combines capabilities from two open-source packages, including the interface reconstruction library (IRL), a library of computational geometry routines to enable the volume of fluid (VOF) method, and PeleLM, a solver for the reacting Navier-Stokes equations. Additionally, surface tension is implemented using the continuum surface force (CSF) model with an improved height function technique in the volume fraction field. Spurious errors in volume fraction arising from our combined strategy are corrected through a topology-based method that improves both numerical stability and accuracy. Multiple validation simulations are conducted, including (i) translations and rotations of Zalesak's disk, (ii) a stationary circular droplet with surface tension, (iii) an oscillating elliptical droplet, and (iv) three-dimensional deformation of a spherical droplet. Results indicate that the combined scheme retains the favorable properties of each of the component algorithms.

42 ENGINEERING↗

A practical model for fluid flow in discrete-fracture porous media by using the numerical manifold method

Here in this study, a numerical manifold method (NMM) model is developed to analyze flow in porous media with discrete fractures in a non-conforming mesh. This new model is based on a two-cover-mesh system with a uniform triangular mathematical mesh and boundary/fracture-divided physical covers, where local independent cover functions are defined. The overlapping parts of the physical covers are elements where the global approximation is defined by the weighted average of the physical cover functions. The mesh is generated by a tree-cutting algorithm. A new model that does not introduce additional degrees of freedom (DOF) for fractures was developed for fluid flow in fractures. The fracture surfaces that belong to different physical covers are used to represent fracture flow in the direction of the fractures. In the direction normal to the fractures, the fracture surfaces are regarded as Dirichlet boundaries to exchange fluxes with the rock matrix. Furthermore, fractures that intersect with Dirichlet or Neumann boundaries are considered. Simulation examples are designed to verify the efficiency of the tree-cutting algorithm, the calculation's independency from the mesh orientation, and accuracy when modeling porous media that contain fractures with multiple intersections and different orientations. The simulation results show good agreement with available analytical solutions. Finally, the model is applied to cases that involve nine intersecting fractures and a complex network of 100 fractures, both of which achieve reasonable results. The new model is very practical for modeling flow in fractured porous media, even for a geometrically complex fracture network with large hydraulic conductivity contrasts between fractures and the matrix.

58 GEOSCIENCES↗

Improved natural convection heat transfer correlations for reactor cavity cooling systems of high-temperature gas-cooled reactors: From computational fluid dynamics to Pronghorn

The Reactor Cavity Cooling System (RCCS) is a common reactor safety system in High Temperature Gas Cooled Reactors (HTGR) that removes heat from the Reactor Pressure Vessel (RPV) by radiation ($\sim 80\%$) and natural convection ($\sim 20\%$). For simulation of accident scenarios of HTGRs, intermediate fidelity and system codes models must be employed for limiting the models' execution time. While accurate quantification of the radiative heat transfer is available in these models, quantification of natural convection must rely on correlations of questionable accuracy for the Nusselt number. Commonly used correlations are based in experiments performed at low Rayleigh numbers and/or using isothermal walls in simplified geometries. Here, this work improves on the accuracy of natural convection heat transfer correlations in support for HTGR designs. These correlations include both local and average Nusselt numbers as a function of the global Rayleigh number, the local Rayleigh number, and the temperature profile at the hot wall of the RCCS. In the absence of dedicated experiments and the difficulty of performing high-fidelity simulations at realistic Rayleigh numbers, the data to fit the correlations are generated with Computational Fluid Dynamics (CFD) using Reynolds Averaged Navier-Stokes (RANS) models. First, a careful selection of the RANS turbulence model is performed by comparing the results obtained with different RANS turbulence models against high fidelity simulations of natural convection at $Ra \ 1 \times 10^{11}$ in a rectangular cavity. Next, the selected model is used to perform simulations of an HTGR cavity at different high Rayleigh numbers $\in [6.1 \times 10^{11},2.9 \times 10^{13}]$ to encompass several HTGR designs, assuming an isothermal RPV wall. The results obtained are used to fit a correlation for the average and space-varying Nusselt number as a function of the global and local Rayleigh numbers via a sparsity-promoting least-squares method. The selected RANS model is then used to perform simulations of a PBMR 400 HTGR cavity with the temperature profiles at the RPV wall obtained during a PLOFC transient. We use the results obtained to fit a temperature-dependent correction to the space-varying Nusselt number with the sparsity-promoting least-squares method. The results obtained in this work, enable system-level codes, such as Pronghorn, to perform higher-fidelity simulations of the heat exchange process in the RCCS while still maintaining a low computational cost.

42 ENGINEERING↗

Cosmological fluids with logarithmic equation of state

We investigate the cosmological applications of fluids having an equation of state which is the analog to the one related to the isotropic deformation of crystalline solids, that is containing logarithmic terms of the energy density, allowing additionally for a bulk viscosity. We consider two classes of scenarios and we show that they are both capable of triggering the transition from deceleration to acceleration at late times. Furthermore, we confront the scenarios with data from Supernovae type Ia (SN Ia) and Hubble function observations, showing that the agreement is excellent. Moreover, we perform a dynamical system analysis and we show that there exist asymptotic accelerating attractors, arisen from the logarithmic terms as well as from the viscosity, which in most cases correspond to a phantom late-time evolution. Finally, for some parameter regions we obtain a nearly de Sitter late-time attractor, which is a significant capability of the scenario since the dark energy, although dynamical, stabilizes at the cosmological constant value.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Technical and economic evaluation of heat transfer fluids for a TES system integrated to an advanced nuclear reactor

The utilization of thermal energy storage technology has emerged as a potential enhancement for nuclear power plants. Although nuclear energy systems possess the ability to adjust their energy output, prolonged variations in production can impact the plant's overall efficiency and economic viability. However, the nuclear industry can capitalize on thermal energy storage to bolster the power plant's economics by leveraging ancillary services and market hedging strategies. Here this research aims to advance the development of thermal energy storage for advanced nuclear reactors by assessing the thermophysical properties of various heat transfer fluids, including FLiNaK, KCl-MgCl 2 , LiCl-KCl, (LiNaK) 2 CO 3 , NaF-ZrF 4 , and KF-ZrF 4 , at temperatures ranging from 500 to 900oC. The assessment is conducted based on thermophysical correlations established in previous studies and employs figures of merit as a metric to evaluate the heat transfer performance of different salt candidates. Additionally, a cost analysis is conducted to provide an idea of the potential cost associated with each salt candidate.

25 ENERGY STORAGE↗

Cerebrospinal fluid CD4+ T lymphocyte-derived miRNA-let-7b can enhances the diagnostic performance of Alzheimer's disease biomarkers

Highlights: • Let-7b in CSF is mainly derived from CD4+ T lymphocytes. • Let-7b is associated with the AD biomarkers. • Let-7b can improve the diagnostic performance of AD biomarkers. Alzheimer's disease is very difficult to clinically diagnose. miRNAs constitute the promising next generation of Alzheimer's disease (AD) biomarkers and have the potential to diagnose neurodegenerative diseases. In this study, 94 subjects underwent extensive dementia screening. Let-7b miRNA was found to increase in association with the progression of AD, and the increase in let-7b miRNA was mainly due to CD4+ T cells in the cerebrospinal fluid (CSF). Additionally, let-7b was positively correlated with the expression of t-Tau and p-Tau. The inclusion of let-7b in Aβ40-Aβ42 or t-tau–p-tau logistic regression and receiver operating characteristic predictive models can significantly improve the diagnostic performance. Overall, let-7b has an important association with the pathology of AD and can be used as an adjunct to improve the diagnostic performance of traditional AD biomarkers.

60 APPLIED LIFE SCIENCES↗

Analysis of maximum pressure drop for a flat-base spouted fluid bed

For design purposes of the blower power requirements during startup of a spouting bed process, knowledge of the maximum pressure drop across a spouting bed at the onset of spouting is required. A survey of the literature for this information lead to only a few correlations which required information from a spouting bed test to be applicable. Therefore, an experimental investigation of this pressure drop and its associated superficial gas velocity in a flat based spouted bed operating with and without fluidization has been conducted. Measurements were performed using a 10 cm cylindrical bed with different static bed heights and two Geldard group B particles (Al2O3 and HDPE). The results show that the taller static bed height creates a larger maximum pressure drop across the bed, as expected. The maximum pressure drop also increases with increasing fluidized gas velocity. In conclusion, the evolution of maximum pressure drop and its velocity were evaluated and a correlation for the maximum pressure drop and its corresponding velocity for spouted and spouted fluid beds were obtained.

42 ENGINEERING↗

Computational fluid dynamics study of full-scale aerobic bioreactors: Evaluation of gas-liquid mass transfer, oxygen uptake, and dynamic oxygen distribution

Hydrodynamics, oxygen transfer, and oxygen uptake in bubble-column and airlift bioreactors were studied using multiphase Euler-Euler computational fluid dynamics (CFD) simulations. Interphase mass transfer of oxygen was modeled with a liquid mass-transfer coefficient and sustained driving force provided by a phenomenological model for microbial oxygen uptake rate (OUR). Laboratory-scale reactor simulations of a bubble-column (0.15 m diameter and 0.75 m initial liquid height) showed reasonable agreement with gas holdup and mass transfer experiments reported in the literature. Commercial-scale bubble-column and airlift reactor simulations (5 m diameter and 25 m initial liquid height) were simulated using this validated model. Similar trends for the variation of overall gas holdup and oxygen concentrations with superficial velocity were observed for both of the commercial-scale reactors. However, the simulation results indicate differences in hydrodynamics, such as better recirculation in the airlift reactors that enables favorable distribution of oxygen in the reactor.

09 BIOMASS FUELS↗