Search NASA⌕ Search

SEARCH · Search NASA

Results for “High gradient acceleration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Atomistic self-sputtering mechanisms of rf breakdown in high-gradient linacs.

Molecular dynamics (MD) models of sputtering solid and liquid surfaces - including the surfaces charged by interaction with plasma, Coulomb explosion, and Taylor cone formation - were developed. MD simulations of self-sputtering of a crystalline (1 0 0) copper surface by Cu{sup +} ions in a wide range of ion energies (50 eV-50 keV) were performed. In order to accommodate energetic ion impacts on a target, a computational model was developed that utilizes MD to simulate rapid atomic collisions in the central impact zone, and a finite-difference method to absorb the energy and shock wave for the collisional processes occurring at a longer time scales. The sputtering yield increases if the surface temperature rises and the surface melts as a result of heat from plasma. Electrostatic charging of the surface under bombardment with plasma ions is another mechanism that can dramatically increase the sputtering yield because it reduces the surface binding energy and the surface tension. An MD model of Taylor cone formation at a sharp tip placed in a high electric field was developed, and the model was used to simulate Taylor cone formation for the first time. Good agreement was obtained between the calculated Taylor cone angle (104.3{sup o}) and the experimental one (98.6{sup o}). A Coulomb explosion (CE) was proposed as the main surface failure mechanism triggering breakdown, and the dynamics of CE was studied by MD.

43 PARTICLE ACCELERATORS↗

Heat load of a GaAs photocathode in an SRF electron gun

A great deal of effort has been made over the last decades to develop a better polarized electron source for high energy physics. Several laboratories operate DC guns with a gallium arsenide photocathode, which yield a highly polarized electron beam. However, the beam's emittance might well be improved by using a superconducting radio frequency (SRF) electron gun, which delivers beams of a higher brightness than that from DC guns because the field gradient at the cathode is higher. SRF guns with metal and CsTe cathodes have been tested successfully. To produce polarized electrons, a Gallium-Arsenide photo-cathode must be used: an experiment to do so in a superconducting RF gun is under way at BNL. Since a bulk gallium arsenide (GaAs) photocathode is normal conducting, a problem arises from the heat load stemming from the cathode. In this paper, we present our measurements of the electrical resistance of GaAs at cryogenic temperatures, a prediction of the heat load and verification by measuring the quality factor of the gun with and without the cathode at 2 K. We simulate heat generation and flow from the GaAs cathode using the ANSYS program. Finally, by following the findings with the heat load model, we designed and fabricated a new cathode holder (plug) to decrease the heat load from GaAs.

2 K test↗

Accelerating full waveform inversion via source stacking and cross-correlations

SUMMARY Accurate synthetic seismic wavefields can now be computed in 3-D earth models using the spectral element method (SEM), which helps improve resolution in full waveform global tomography. However, computational costs are still a challenge. These costs can be reduced by implementing a source stacking method, in which multiple earthquake sources are simultaneously triggered in only one teleseismic SEM simulation. One drawback of this approach is the perceived loss of resolution at depth, in particular because high-amplitude fundamental mode surface waves dominate the summed waveforms, without the possibility of windowing and weighting as in conventional waveform tomography. This can be addressed by redefining the cost-function and computing the cross-correlation wavefield between pairs of stations before each inversion iteration. While the Green’s function between the two stations is not reconstructed as well as in the case of ambient noise tomography, where sources are distributed more uniformly around the globe, this is not a drawback, since the same processing is applied to the 3-D synthetics and to the data, and the source parameters are known to a good approximation. By doing so, we can separate time windows with large energy arrivals corresponding to fundamental mode surface waves. This opens the possibility of designing a weighting scheme to bring out the contribution of overtones and body waves. It also makes it possible to balance the contributions of frequently sampled paths versus rarely sampled ones, as in more conventional tomography. Here we present the results of proof of concept testing of such an approach for a synthetic 3-component long period waveform data set (periods longer than 60 s), computed for 273 globally distributed events in a simple toy 3-D radially anisotropic upper mantle model which contains shear wave anomalies at different scales. We compare the results of inversion of 10 000 s long stacked time-series, starting from a 1-D model, using source stacked waveforms and station-pair cross-correlations of these stacked waveforms in the definition of the cost function. We compute the gradient and the Hessian using normal mode perturbation theory, which avoids the problem of cross-talk encountered when forming the gradient using an adjoint approach. We perform inversions with and without realistic noise added and show that the model can be recovered equally well using one or the other cost function. The proposed approach is computationally very efficient. While application to more realistic synthetic data sets is beyond the scope of this paper, as well as to real data, since that requires additional steps to account for such issues as missing data, we illustrate how this methodology can help inform first order questions such as model resolution in the presence of noise, and trade-offs between different physical parameters (anisotropy, attenuation, crustal structure, etc.) that would be computationally very costly to address adequately, when using conventional full waveform tomography based on single-event wavefield computations.

Romanowicz, Barbara↗

Quench degradation limit of multifilamentary AgBi 2 Sr 2 CaCu 2 O x round wires

Understanding safe operating limits of composite superconducting wires is important for the design of superconducting magnets. Here we report measurements of quench-induced critical current density Jc degradation in commercial Ag/Bi 2 Sr 2 CaCu 2 O x (Bi-2212) round wires using heater-induced quenches at 4.2 K in self magnetic field that reveal a general degradation behavior. J c degradation strongly depends on the local hot spot temperature T max , and is nearly independent of operating current, the temperature gradient along the conductor dT max /dx, and the temperature rising rate dT max /dt. Both J c and n value (where n is an index of the sharpness of the superconductor-to-normal transition) exhibit small but irreversible degradation when T max exceeds 400-450 K, and large degradation occurs when Tmax exceeds 550 K. This behavior was consistently found for a series of Bi-2212 wires with widely variable wire architectures and porosity levels in the Bi-2212 filaments, including a wire processed using a standard partial melt processing and in which Bi-2212 filaments are porous, an overpressure processed wire in which Bi-2212 filaments are nearly porosity-free and that has a J c (4.2 K, self field) exceeding 8000 A/mm 2 , and a wire that has nearly no filament to filament bridges after reaction. Microstructural observations of degraded wires reveal cracks in the Bi-2212 filaments perpendicular to the wire axis, indicating that the quench-induced I c degradation is primarily driven by strain. These results further suggest that the quench degradation temperature limit depends on the strain state of Bi-2212 filaments and this dependence shall be carefully considered when engineering a high-field Bi-2212 magnet.

43 PARTICLE ACCELERATORS↗

Motion of Drops on Surfaces with Wettability Gradients

A liquid drop present on a solid surface can move because of a gradient in wettability along the surface, as manifested by a gradient in the contact angle. The contact angle at a given point on the contact line between a solid and a liquid in a gaseous medium is the angle between the tangent planes to the liquid and the solid surfaces at that point and is measured within the liquid side, by convention. The motion of the drop occurs in the direction of increasing wettability. The cause of the motion is the net force exerted on the drop by the solid surface because of the variation of the contact angle around the periphery. This force causes acceleration of an initially stationary drop, and leads to its motion in the direction of decreasing contact angle. The nature of the motion is determined by the balance between the motivating force and the resisting hydrodynamic force from the solid surface and the surrounding gaseous medium. A wettability gradient can be chemically induced as shown by Chaudhury and Whitesides who provided unambiguous experimental evidence that drops can move in such gradients. The phenomenon can be important in heat transfer applications in low gravity, such as when condensation occurs on a surface. Daniel et al have demonstrated that the velocity of a drop on a surface due to a wettability gradient in the presence of condensation can be more than two orders of magnitude larger than that observed in the absence of condensation. In the present research program, we have begun to study the motion of a drop in a wettability gradient systematically using a model system. Our initial efforts will be restricted to a system in which no condensation occurs. The experiments are performed as follows. First, a rectangular strip of approximate dimensions 10 x 20 mm is cut out of a silicon wafer. The strip is cleaned thoroughly and its surface is exposed to the vapor from an alkylchlorosilane for a period lasting between one and two minutes inside a desiccator. This is done using an approximate line source of the vapor in the form of a string soaked in the alkylchlorosilane. Ordinarily, many fluids, including water, wet the surface of silicon quite well. This means that the contact angle is small. But the silanized surface resists wetting, with contact angles that are as large as 100 degs. Therefore, a gradient of wettability is formed on the silicon surface. The region near the string is highly hydrophobic, and the contact angle decreases gradually toward a small value at the hydrophilic end away from this region. The change in wettability occurs over a distance of several mm. The strip is placed on a platform within a Plexiglas cell. Drops of a suitable liquid are introduced on top of the strip near the hydrophobic end. An optical system attached to a video camera is trained on the drop so that images of the moving drop can be captured on videotape for subsequent analysis. We have performed preliminary experiments with water as well as ethylene glycol drops. Results from these experiments will be presented in the poster. Future plans include the refinement of the experimental system so as to permit images to be recorded from the side as well as the top, and the conduct of a systematic study in which the drop size is varied over a good range. Experiments will be conducted with different fluids so as to obtain the largest possible range of suitably defined Reynolds and Capillary numbers. Also, an effort will be initiated on theoretical modeling of this motion. The challenges in the development of the theoretical description lie in the proper analysis of the region in the vicinity of the contact line, as well as in the free boundary nature of the problem. It is known that continuum models assuming the no slip condition all the way to the contact line fail by predicting that the stress on the solid surface becomes singular as the contact line is approached. One approach for dealing with this issue has been to relax the no-slip boundary condition using the Navier model. Molecular dynamics simulations of the contact line region show that for a non-polar liquid on a solid surface, the no-slip boundary condition is in fact incorrect near the contact line. Furthermore, the same simulations also show that the usual relationship between stress and the rate of deformation breaks down in the vicinity of the contact line. In developing continuum theoretical models of the system, we shall accommodate this knowledge to the extent possible.

Subramanian, R. Shankar↗

Finite element analysis of the impact of beam heating mode in molten salt corrosion experiments employing simultaneous ion irradiation

Finite element analysis was used to investigate the temperature and stress profiles that develop in 316L stainless steel membranes being irradiated using different proton beam conditions in contact with a molten salt environment. It was shown that in addition to a nonuniform irradiation profile, a focused 2 MeV proton beam leads to very strong temperature and stress gradients in the membrane, introducing highly localized driving forces that complicate and even compromise the integrity and reliability of the experimental results of corrosion studies. Here, the use of a focused beam in corrosion studies can create experimental artifacts that may misrepresent the true corrosion behavior. In contrast, the use of a rastered beam is shown to distribute the protons and resulting radiation damage uniformly across the membrane face, and more importantly, results in temperature and stress profiles that are not only very uniform but are of much lower magnitude. The use of a rastered beam during molten salt corrosion experiments is therefore recommended to achieve uniform damage rates, thereby reducing both gradients and magnitudes of the temperature and stress distributions.

43 - PARTICLE ACCELERATORS↗

Interactive Visualization of Multi-Group Cross Sections on High-Fidelity Spatial Meshes

Core simulation tools utilizing Monte Carlo transport methods represent the 'Holy Grail' for nuclear reactor analysis. However, deterministic transport methods pose a number of advantages to Monte Carlo from a computational perspective, which seems likely to make these methods more viable in the near to intermediate term. Deterministic methods almost universally discretize the energy domain in a few to hundreds of energy groups. One of the key challenges for deterministic transport-based methods to be viable is accurate, reactor agnostic multi-group cross section generation. This paper describes tools for data processing and visualization of multigroup cross sections generated on high-fidelity spatial meshes from the OpenMC Monte Carlo code. Next generation deterministic transport reactor core modeling tools will require multi-group cross section (MGXS) generation on high-fidelity spatial meshes. High-fidelity MGXS are necessary for the accurate simulation of neutron physics in nuclear reactors with a high degree of spectral heterogeneity - e.g., large localized neutron flux gradients throughout a reactor core. Although many local (e.g., pin cell) approximations have been developed to model the scalar flux to compute spectral-averaged MGXS, these techniques cannot account for complex intra-pin and intra-assembly spatial self-shielding effects. Monte Carlo presents the most accurate method for reactor agnostic multi-group cross section generation since it does not require the use of local approximations to the flux. Monte Carlo has been proposed as a highly desirable framework for reactor agnostic cross section generation for many years. Monte Carlo methods can effectively embed all of the relevant spectral effects into the MGXS through the random particle tracking and interaction sampling processes. Previous work has applied MCNP and Serpent to compute few-group constants for diffusion calculations, and OpenMC to compute multi-group cross sections for transport-based methods. The primary difficulty with using Monte Carlo for MGXS generation is the tremendous computational resources required to adequately converge multi-group cross sections in each spatial region and energy group. Recent development of the OpenMC Monte Carlo code for high-performance computing platforms has made multigroup cross section generation from Monte Carlo more tractable in the foreseeable future. The recent release of OpenMC v0.7.1 includes a new Python-based module for MGXS generation. The MGXS generation module leverages many of the algorithms and features for 'big data' analysis of large tally datasets on complex spatial meshes. This paper describes the data management workflow and visualization tools which have been developed to explore the plethora of MGXS data generated with OpenMC. It is the authors' hope that the development of the visualization tool described in this paper will ultimately enable the design of machine learning algorithms to accelerate the convergence rate of high-fidelity multi-group cross section generated with Monte Carlo. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Field Cancellation Algorithm for Constructing Economical Planar Permanent Magnet (PM) Multipoles With Large High Quality Field Apertures

In recent years studies have been initiated on a new class of multipole field generators consisting of cuboid planar permanent magnet (PM) pieces arranged in biplanar arrays of 2-fold rotational symmetry. These structures, first introduced for Free Electron Laser (FEL) applications, are based on reducing the rotational symmetry of conventional N-pole field generators from N-fold to 2-fold. One consequence of this reduction is a large higher-multipole content in a planar PM multipole's field at distances relatively close to the structure's axis, making it generally unsuitable for applications requiring a large high-quality field aperture. In this paper we outline an economical field-cancellation algorithm that can substantially decrease the harmonic content of a planar PM's field without breaking its biplanar geometry or 2-fold rotational symmetry. An economical field-cancellation algorithm has been described which will allow the fabrication of bi-planar quadrupoles and sextupoles with high-quality fields using a manageably small number of PM pieces. For higher order N-poles the number of pieces required to cancel a given number of successively-higher multipole components will also increase linearly; nevertheless, the practicability of fabricating octupoles and higher N-poles of this type should be considered a subject of continuing r&d. Since the removal of a large number of successive multipole components essentially increases the transverse region over which the N-pole's field is dominated by its leading N-pole field component, the fabrication of quadrupoles and sextupoles of the type described in this paper should lead to their introduction in storage ring applications. One potentially important application in this area is as distributed focusing elements installed into very-short-period, small-gap undulators (e.g., as a FODO lattice). The installation is rendered feasible by the very small vertical height of the biplanar N-poles (on the order of a millimeter), which, notwithstanding, doesn't prevent them from attaining focusing gradients on the order of several hundred T/m. If proven, this would allow short-period undulators of substantial length (viz., >>b) to be operated on storage rings, potentially transforming the optimality and economy of synchrotron radiation sources toward more favorable regimes.

43 PARTICLE ACCELERATORS↗

EVALUATION OF OPERATION TEMPERATURES UNDER NATURAL CONVECTION HELIUM FLOW IN A CONFINED CAVITY

The Spallation Neutron Source (SNS) is a high-power accelerator-based pulsed neutron source led by Oak Ridge National Laboratory (ORNL) to achieve high fluxes of neutrons for scientific experiments. Active and passive cooling of the systems and parts forming the SNS have been considered to warrant the safe operation of the facility. The diverse cooling systems make use of conjugated heat transfer mechanisms to provide a stable operation temperature for all components in the machine. Thermal power deposited into stainless-steel piping lines due to particle radiation may reach values of up to 1.2 W/cc in the regions located closer to the center of the lower IRP. These energy deposition levels, in not actively cooled components, such as the transfer-line-outer-vacuum-layer may increase the temperature of the component beyond design requirement limitations. The evaluation of the operation temperatures for the former components relies in the assumption that a low-pressure helium atmosphere provides enough heat removal capacity based on natural convection phenomena. In this work, the evaluation of steady state temperatures in components such as the CMS transfer lines has been evaluated using computational fluid dynamics (CFD), analytical correlations and experimental measurements. The companion experiments were conducted in a closed helium system at pressures varying from 1.1 to 1.5 bar. A copper rod was affixed horizontally between viewing windows and heated at constant power, and measurements were made of both the rod temperature and ambient temperature via a system fiberoptic distributed temperature sensors and RTDs. It was found that the measured heat transfer coefficients agree well with the predictions of Churchill and Chu correlations across the range of cases considered. Additionally, the ambient helium volume above the rod was imaged via background oriented schlieren (BOS), and these data was used to determine the line-averaged density gradients in this region. These gradients were compared to simulation data to validate the predictions of natural convection simulations.

Dominguez-Ontiveros, Elvis [ORNL] (ORCID:000000018↗

Linac-based extracranial radiosurgery with Elekta volumetric modulated arc therapy and an anatomy-based treatment planning system: Feasibility and initial experience

We reported our initial experience in using Elekta volumetric modulated arc therapy (VMAT) and an anatomy-based treatment planning system (TPS) for single high-dose radiosurgery (SRS-VMAT) of liver metastases. This study included a cohort of 12 patients treated with a 26-Gy single fraction. Single-arc VMAT plans were generated with Ergo++ TPS. The prescription isodose surface (IDS) was selected to fulfill the 2 following criteria: 95% of planning target volume (PTV) reached 100% of the prescription dose and 99% of PTV reached a minimum of 90% of prescription dose. A 1-mm multileaf collimator (MLC) block margin was added around the PTV. For a comparison of dose distributions with literature data, several conformity indexes (conformity index [CI], conformation number [CN], and gradient index [GI]) were calculated. Treatment efficiency and pretreatment dosimetric verification were assessed. Early clinical data were also reported. Our results reported that target and organ-at-risk objectives were met for all patients. Mean and maximum doses to PTVs were on average 112.9% and 121.5% of prescribed dose, respectively. A very high degree of dose conformity was obtained, with CI, CN, and GI average values equal to 1.29, 0.80, and 3.63, respectively. The beam-on-time was on average 9.3 minutes, i.e., 0.36 min/Gy. The mean number of monitor units was 3162, i.e., 121.6 MU/Gy. Pretreatment verification (3%-3 mm) showed an optimal agreement with calculated values; mean γ value was 0.27 and 98.2% of measured points resulted with γ < 1. With a median follow-up of 16 months complete response was observed in 12/14 (86%) lesions; partial response was observed in 2/14 (14%) lesions. No radiation-induced liver disease (RILD) was observed in any patients as well no duodenal ulceration or esophagitis or gastric hemorrhage. In conclusion, this analysis demonstrated the feasibility and the appropriateness of high-dose single-fraction SRS-VMAT in liver metastases performed with Elekta VMAT and Ergo++ TPS. Preliminary clinical outcomes showed a high rate of local control and minimum incidence of acute toxicity.

61 RADIATION PROTECTION AND DOSIMETRY↗

Compare low-gain 1D and 3D models toward a storage ring-based X-ray free-electron-laser oscillator

Fourth-generation diffraction-limited synchrotron light sources (DL-SLS) present a compelling platform for advanced light source applications due to their ultra-low emittance (around tens of picometers), sub-micrometer beam stability, and high repetition rates (greater than 1 MHz). Despite these advantages, fundamental limitations, such as long bunch durations (tens of picoseconds), large relative energy spread (~10⁻³), and low peak current (<300 A), have hindered their effectiveness in free-electron laser (FEL) applications. Using a low-gain three-dimensional (3D) model based on NSLS-II upgrade lattice parameters, we demonstrate that a 6% single-pass gain is achievable with an optimized transverse gradient undulator (TGU). Concurrently, recent advances in X-ray optics—specifically, a four-mirror bow-tie resonator utilizing diamond mirrors and beryllium compound refractive lenses (CRLs)—enable total round-trip losses below 4% and an output coupling efficiency near 1%, rendering a Storage Ring based X-ray FEL oscillator (XFELO) a realistic possibility. In the 3D framework, the TGU effectively mitigates the detrimental effects of large energy spread by spatially dispersing the beam, leading to enhanced gain relative to conventional one-dimensional (1D) models. We establish both analytical and numerical connections between the 1D and 3D descriptions, leveraging GENESIS simulations to map equivalent gain conditions. While 1D resonance is defined in the energy domain, the 3D TGU system shifts the resonance dependence to transverse gradient and dispersion parameters. Once optimized, this framework allows predictive modeling using 1D formulas, which can then be validated through full 3D simulations.

43 PARTICLE ACCELERATORS↗

The DOSIMAP, a high spatial resolution tissue equivalent 2D dosimeter for LINAC QA and IMRT verification

The continual need for more accurate and effective techniques in radiation therapy makes it necessary to devise new control means combining high spatial resolution as well as high dose accuracy. Intensity modulated radio therapy (IMRT) allows highly conformed fields with high spatial gradient and therefore requires a precise monitoring of all the multileaf positions. In response to this need, the authors have developed a new 2D tissue equivalent dosimeter with high spatial resolution. A plastic scintillator sheet is sandwiched between two polystyrene blocks and the emitted light is captured by a high resolution camera. A newly developed procedure described herein allows efficient discrimination of the scintillation from the parasitic Cerenkov radiation. This processing is applied on the cumulated image from a sequence of images taken during an irradiation field at a rate of 10 images/s. It provides a high resolution mapping of the cumulated dose in quasireal time. The dosimeter is tissue equivalent (ICRU-44) and works both for electrons and photons without complex parameter adjustment since phantom and detector materials are identical. Instrument calibration is simple and independent of the irradiation conditions (energy, fluence, quality, ...). In this article, the authors present the principle of the dosimeter and its calibration procedure. They compare the results obtained for photons and electron beams with ionization chamber measurements in polystyrene. Technical specifications such as accuracy and repeatability are precisely evaluated and discussed. Finally, they present different IMRT field measurements and compare DOSIMAP measurements to TPS simulations and dosimetric film profiles. The results confirm the excellent spatial resolution of the instrument and its capacity to inspect the leaf positions for each segment of a given field.

61 RADIATION PROTECTION AND DOSIMETRY↗

Acceleration of polarized protons in the AGS

The high energy (s{sup 1/2} = 500 GeV) polarized proton beam experiments performed in RHIC, require high polarization of the proton beam. With the AGS used as the pre-injector to RHIC, one of the main tasks is to preserve the polarization of the proton beam, during the beam acceleration in the AGS. The polarization preservation is accomplished by the two partial helical magnets [1,2,3,4,5,6,7] which have been installed in AGS, and help overcome the imperfection and the intrinsic spin resonances which occur during the acceleration of protons. This elimination of the intrinsic resonances is accomplished by placing the vertical tune Q{sub y} at a value close to 8.98, within the spin-tune stop-band created by the snake. At this near integer tune the perturbations caused by the partial helical magnets is large resulting in large beta and dispersion waves. To mitigate the adverse effect of the partial helices on the optics of the AGS, we have introduced compensation quads[2] in the AGS. In this paper we present the beam optics of the AGS which ameliorates this effect of the partial helices.

43 PARTICLE ACCELERATORS↗

Gravitational Effects on Flow Instability and Transition in Low Density Jets

Recent experiments have shown that low-density gas jets injected into a high-density ambient gas undergo an instability mode, leading to highly-periodic oscillations in the flow-field for certain conditions. The transition from laminar to turbulent flow in these jets is abrupt, without the gradual change in scales. Even the fine scale turbulent structure repeats itself with extreme regularity from cycle to cycle. Similar observations were obtained in buoyancy-dominated and momentum-dominated jets characterized by the Richardson numbers, Ri = [gD(rho(sub a)-rho(sub j))/rho(sub j)U(sub j)(exp 2) ] where g is the gravitational acceleration, D is the jet diameter, rho(sub a) and rho(sub a) are, respectively, the free-stream and jet densities, and U(sub j) is the mean jet exit velocity. At high Richardson numbers, the instability is presumably caused by buoyancy since the flow-oscillation frequency (f) or the Strouhal number, St = [fD/U(sub j)] scales with Ri. In momentum-dominated jets, however, the Strouhal number of the oscillating flow is relatively independent of the Ri. In this case, a local absolute instability is predicted in the potential core of low-density jets with S [= rho(sub j)/rho(sub a)] < 0.7, which agrees qualitatively with experiments. Although the instability in gas jets of high Richardson numbers is attributed to buoyancy, direct physical evidence has not been acquired in experiments. If the instability is indeed caused by buoyancy, the near-field flow structure of the jet will change significantly when the buoyancy is removed, for example, in the microgravity environment. Thus, quantitative data on the spatial and temporal evolutions of the instability, length and time scale of the oscillating mode and its effects on the mean flow and breakdown of the potential core are needed in normal and microgravity to delineate gravitational effects in buoyant jets. In momentum dominated low-density jets, the instability is speculated to originate in the potential core. However, experiments have not succeeded in identifying the direct physical cause of the instability. For example, the theory predicts an oscillating mode for S<0.62 in the limit of zero momentum thickness, which contradicts with the experimental findings of Kyle and Sreenivasan. The analyses of momentum-dominated jets neglect buoyancy effects because of the small Richardson number. Although this assumption is appropriate in the potential core, the gravitational effects are important in the annular region surrounding the jet, where the density and velocity gradients are large. This reasoning provides basis for the hypothesis that the instability in low Richardosn number jets studied by Kyle and Sreenivasan and Monkewitz et al. is caused by buoyancy. The striking similarity in characteristics of the instability and virtually the identical conclusions reached by Subbarao and Cantwell in buoyant (Ri>0.5) helium jets on one hand and by Kyle and Sreenivasan in momentum-dominated (Ri<1x10(exp -3)) helium jets on the other support this hypothesis. However, quantitative experiments in normal and microgravity are necessary to obtain direct physical evidence of buoyancy effects on the flow instability and structure of momentum-dominated low-density jets. The primary objective of this new research project is to quantify how buoyancy affects the flow instability and structure in the near field of low-density jets. The flow will be described by the spatial and temporal evolutions of the instability, length and time scales of the oscillating mode, and the mean and fluctuating concentration fields. To meet this objective, concentration measurements will be obtained across the whole field using quantitative Rainbow Schlieren Deflectometry, providing spatial resolution of 0.1mm and temporal resolution of 0.017s to 1ms. The experimental effort will be supplemented with linear stability analysis of low-density jets by considering buoyancy. The first objective of this research is to investigate the effects of gravity on the flow instability and structure of low-density jets. The flow instability in these jets has been attributed to buoyancy. By removing buoyancy in our experiments, we seek to obtain the direct physical evidence of the instability mechanism. In the absence of the instability, the flow structure will undergo a significant change. We seek to quantify these changes by mapping the flow field (in terms of the concentration profiles) of these jets at non-buoyant conditions. Such information is presently lacking in the existing literature. The second objective of this research is to determine if the instability in momentum-driven, low-density jets is caused by buoyancy. At these conditions, the buoyancy effects are commonly ignored because of the small Richardson based on global parameters. By eliminating buoyancy in our experiments, globally as well as locally, we seek to examine the possibility that the instability mechanism in self-excited, buoyant or momentum-driven jets is the same. To meet this objective, we would quantify the jet flow in normal and microgravity, while systematically decreasing the Richardson number from buoyancy-driven to momentum driven flow regime. The third objective of this research is to perform a linear stability analysis of low-density gas jets by including the gravitational effects. The flow oscillations in these jets are attributed to an absolute instability, whereby the disturbance grows exponentially at the site to ultimately contaminate the entire flow field. We seek to study the characteristics of both convective and absolute instabilities and demarcate the boundary between them.

Agrawal A. K.↗

Near integer tune for polarization preservation in the AGS

The high energy (T = 250 GeV) polarized proton beam experiments performed in RHIC, require high polarization of the beam. In order to preserve the polarization of the proton beam, during the acceleration in the AGS, which is the pre-injector to RHIC, we have installed in AGS two partial helical magnets which minimize the loss of the beam polarization caused by the various intrinsic spin resonances occurring during the proton acceleration. The minimization of the polarization loss during the acceleration cycle, requires that the vertical tune of the AGS is between the values of 8.97 and 8.985 during the acceleration. With the AGS constrained to run at near integer tune {approx}8.980, the perturbations to the beam caused by the partial helical magnets are large and also result in large beta and dispersion waves. To mitigate the adverse effect of the partial helices on the optics of the AGS, we have installed in specified straight sections of the AGS compensation quads and we have also generated a beam bump at the location of the cold partial helix. In this paper we present the beam optics of the AGS which ameliorates the adverse effect of the two partial helices on the beam optics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Wire-coil insert optimization for high-heat-load/flux synchrotron components

Many synchrotron components require high levels of internal-flow, forced-convection heat transfer to minimize surface temperatures, thermal gradients, and thermally induced stress on high-power beam-interacting surfaces. Wire-coil inserts, physically similar to a common spring, are mechanically fitted inside of component cooling passages to optimize heat transfer performance. They are routinely used in Advanced Photon Source (APS) front end and beamline high-heat-load/flux components to significantly enhance convection heat transfer-up to 400% compared to plain open passages. This has the additional benefit of greatly reducing coolant flow requirements for these components. Using several cooling passage sizes, five different wire sizes, and a range of pitch values, an experimental investigation conducted at the APS has determined the average heat transfer coefficient and resulting pressure loss as a function of water flow rate for 65 different wire-coil inserts. Data from this study have been non-dimensionalized and generalized to yield relationships that can be used to determine the heat transfer performance and resulting pressure loss for any given wire-coil insert that may be used at the APS. Through data reduction, the wire-coil insert characteristic dimensions have also been optimized to yield the highest heat transfer enhancement while minimizing the coolant flow requirements. These generalized expressions for wirecoil inserts will be presented, and they can be used by scientists and engineers during the component design process to evaluate achievable heat transfer performance and associated pressure loss, aiding in the establishment of optimized operating parameters and cooling passage flow distribution schemes.

43 PARTICLE ACCELERATORS↗

Deep VLA Observations of the Cluster 1RXS J0603.3+4214 in the Frequency Range of 1–2 GHz

Here, we report L-band VLA observations of 1RXS J0603.3+4214, a cluster that hosts a bright radio relic, known as the Toothbrush, and an elongated giant radio halo. These new observations allow us to study the surface brightness distribution down to 1 arcsec resolution with very high sensitivity. Our images provide an unprecedented detailed view of the Toothbrush, revealing enigmatic filamentary structures. To study the spectral index distribution, we complement our analysis with published LOFAR and GMRT observations. The bright "brush" of the Toothbrush shows a prominent narrow ridge to its north with a sharp outer edge. The spectral index at the ridge is in the range –0.70 ≤ α ≤ –0.80. We suggest that the ridge is caused by projection along the line of sight. With a simple toy model for the smallest region of the ridge, we conclude that the magnetic field is below 5 μG and varies significantly across the shock front. Our model indicates that the actual Mach number is higher than that obtained from the injection index and agrees well with the one derived from the overall spectrum, namely ${ \mathcal M }={3.78}_{-0.2}^{+0.3}$. The radio halo shows an average spectral index of α = –1.16 ± 0.05 and a slight gradient from north to south. The southernmost part of the halo is steeper and possibly related to a shock front. Excluding the southernmost part, the halo morphology agrees very well with the X-ray morphology. A power-law correlation is found between the radio and X-ray surface brightness.

79 ASTRONOMY AND ASTROPHYSICS↗