Search NASA⌕ Search

SEARCH · Search NASA

Results for “INDUCTANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Interplay between phonon downconversion efficiency, density of states at Fermi energy, and intrinsic energy resolution for microwave kinectic inductance detectors

Microwave Kinetic Inductance detectors (MKIDs) have been recognized as a powerful new tool for single photon detection. These highly multiplexed superconducting devices give timing and energy measurement for every detected photon. However, the full potential of MKID single photon spectroscopy has not been reached , the achieved energy resolution is lower than expected from first principles. Here, we study the efficiency in the phonon downconversion process following the absorption of energetic photons in MKIDs. Assuming previously published material properties, we measure an average downconversion efficiency for three TiN resonators is $\eta$=0.14. We discuss how this efficiency can impact the intrinsic energy resolution of MKID, and how any uncertainty in the unknown density of electron states at the Fermi energy directly affects the efficiency estimations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High speed induction machine

In one embodiment, a high speed induction machine includes: a stator formed of a first plurality of laminations having a thickness of less than approximately 0.01 inch and a winding comprising a coil formed of Litz wire adapted about the stator; and a rotor adapted within the stator. The rotor may include: a rotor core formed of a second plurality of laminations having a second thickness of greater than approximately 0.10 inch and formed of high strength steel and sandwiched between a first end region including at least one first peripheral second lamination and a second end region including at least one second peripheral second lamination, the first end region having a first end ring retained by a first retaining ring adapted there around, the second end region having a second end ring retained by a second retaining ring adapted there around.

Karmaker, Haran Chandra↗

On the Homogeneity of TiN Kinetic Inductance Detectors Produced through Atomic Layer Deposition

The non-homogeneity in the critical temperature $T_{c}$ of an Microwave Kinetic Inductance Detector (MKID) could be caused by non-uniformity in the deposition process of the thin superconducting film. This produces low percent yield and frequency collision in the readout of the MKIDs. Here, we show the homogeneity that offers Atomic Layer Deposition (ALD). We report an improvement of up to a factor of 50 in the fractional variation of the $T_{c}$ for TiN MKIDs fabricated with Atomic Layer Deposition in comparison with MKIDs fabricated with sputtering. We measured the critical temperature of 48 resonators. We extracted the $T_{c}$ of the MKIDs by fitting the fractional resonance frequency to the complex conductivity of their resonators. We observed uniformity on the critical temperature for MKIDs belonging to the same fabrication process, with a maximum change in the $T_{c}$ of 60 mK for MKIDs fabricated on different wafers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structural Study of SiC Nanoparticles Grown by Inductively Coupled Plasma and Laser Pyrolysis for Nano-structured Ceramics Elaboration

Refractory carbide nano-structured ceramics as SiC constitute interesting materials for high temperature applications and particularly for fourth generation nuclear plants. To elaborate such nano-materials, weighable amounts of SiC nano-powders have to be synthesized first with an accurate control of the grain size and stoichiometry. The inductively coupled plasma and the laser pyrolysis techniques, respectively developed at EMPA Thun and CEA Saclay, allow meeting these requirements. Both techniques are able to produce dozens of grams per hour of silicon carbide nano-powders. The particle size can be adjusted down to around 20 nm for the plasma synthesis and even down to 5-10 nm for the laser pyrolysis. The stoichiometry Si/C can be tuned by the addition of methane into the plasma and acetylene for the laser process. (authors)

36 MATERIALS SCIENCE↗

Cold Crucible Induction Melter (CCIM) Demonstration Using a Representative Savannah River Site Sludge Simulant On the Large-Size Pilot Platform at the CEA-Marcoule

The cold-crucible induction melter technology (CCIM) is considered worldwide for industrial implementation to overcome the current limits of high level waste vitrification technologies and to answer future challenges such as: new or difficult sludge compositions, need for improving waste loading, need for high temperatures, and corrosive effluents. More particularly, this technology is being considered for implementation at the US DOE Savannah River site to increase the rate of waste processing while reducing the number of HLW canisters to be produced through increased waste loading and improved waste throughput. A collaborative program involving AREVA, CEA (French Atomic Energy Commission), SRNL (Savannah River National Laboratory) and WSRC (Washington Savannah River Company) has thus been initiated in 2007 to demonstrate vitrification with waste loadings on the order of 50% (versus the current DWPF waste loading of about 35%) with a PUREX-type waste composition (high Fe{sub 2}O{sub 3} composition), and to perform two pilot-scale runs on the large size platform equipped with a 650 mm diameter CCIM at the CEA Marcoule. The objectives of the demonstrations were 1) to show the feasibility of processing a representative SRS sludge surrogate using continuous slurry feeding, 2) to produce a glass that would meet the acceptance specifications with an increased waste loading when compared to what is presently achieved at the DWPF, and 3) achieve improved waste throughputs. This presentation describes the platform and the very encouraging results obtained from the demonstration performed at temperatures, specific throughputs and waste loadings that overcome current DWPF limits. Results from the initial exploratory run and second demonstration run include 1) production of a glass product that achieved the targeted glass composition that was more durable than the standard Environmental Assessment (EA) glass, 2) successful slurry feeding of the CCIM, and 3) promising waste processing rates (at 1250 deg. C and 1300 deg. C melt pool temperature) that could result in processing of the Savannah River HLW faster than could be currently achieved with the existing Joule Heated melter in DWPF. In conclusion, this joint effort conducted by CEA, AREVA, SRNL and WSRC led to very encouraging results, demonstrating waste throughputs 44 % that of the DWPF ceramic melter throughput in a 650 mm CCIM melter for the same waste type with a Sludge Batch 3 PUREX-type waste feed flux of 150 L/h/m{sup 2} demonstrated at 1250 deg. C. The very high waste loading (above 52%) allows reducing the amount of glass to be produced by about 27% to treat the same amount of waste when compared to previous DWPF operation for this specific type of feed, since 27 % less glass is needed to immobilize the same amount of waste. It was also demonstrated, for this type of feed, an unusual behavior with regard to nepheline formation, which would require further evaluation for future applications. The product from the baseline demonstration run, with a waste loading of at least 52%, displayed a very good quality. Stabilized operation close to the maximum throughput was demonstrated. Cesium volatility was apparently between 7 and 12 % (based on glass analysis); however this value is only preliminary. This demonstration also allowed the CEA to better understand the SRS slurry feed behavior and to propose adaptations to the platform for any future demonstrations using this type of feed. Finally, use of a large diameter CCIM ({approx}1 meter) may allow faster processing of the SRS HLW than can be achieved with the current DWPF melter. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced Modeling of Cold Crucible Induction Melting for Process Control and Optimization

The Idaho National Laboratory (INL) and the St. Petersburg Electrotechnical University 'LETI' (ETU) have collaborated on development and validation of an advanced numerical model of the cold crucible induction melting (CCIM) process. This work was conducted in support of the Department of Energy (DOE) Office of Environmental Management Technology and Engineering (EM-20) International Program. The model predicts quasi-steady state temperature distributions, convection cell configurations, and flow field velocities for a fully established melt of low conductivity non-magnetic materials at high frequency operations. The INL/ETU ANSYS{sup C} finite element model is unique in that it has been developed specifically for processing borosilicate glass (BSG) and other glass melts. Specifically, it accounts for the temperature dependency of key material properties, some of which change by orders of magnitude within the temperature ranges experienced (temperature differences of 500 deg. C are common) in CCIM processing of glass, including density, viscosity, thermal conductivity, specific heat, and electrical resistivity. These values, and their responses to temperature changes, are keys to understanding the melt characteristics. Because the model has been validated, it provides the capability to conduct parametric studies to understand operational sensitivities and geometry effects. Additionally, the model can be used to indirectly determine difficult to measure material properties at higher temperatures such as resistivity, thermal conductivity and emissivity. The model can also be used to optimize system design and to predict operational behavior for specific materials and system configurations, allowing automated feedback control. This becomes particularly important when designing melter systems for full-scale industrial applications. (authors)

42 ENGINEERING↗

Induction of NEIL1 and NEIL2 DNA glycosylases in aniline-induced splenic toxicity

The mechanisms by which aniline exposure elicits splenotoxic response, especially the tumorigenic response, are not well-understood. Earlier, we have shown that aniline-induced oxidative stress is associated with increased oxidative DNA damage in rat spleen. The base excision repair (BER) pathway is the major mechanism for the repair of oxidative DNA base lesions, and we have shown an up-regulation of 8-oxoguanine glycosylase 1 (OGG1), a specific DNA glycosylase involved in the removal of 8-hydroxy-2'-deoxyguanosine (8-OHdG) adducts, following aniline exposure. Nei-like DNA glycosylases (NEIL1/2) belong to a family of BER proteins that are distinct from other DNA glycosylases, including OGG1. However, contribution of NEIL1/2 in the repair of aniline-induced oxidative DNA damage in the spleen is not known. This study was, therefore, focused on evaluating if NEILs also contribute to the repair of oxidative DNA lesions in the spleen following aniline exposure. To achieve that, male SD rats were subchronically exposed to aniline (0.5 mmol/kg/day via drinking water for 30 days), while controls received drinking water only. The BER activity of NEIL1/2 was assayed using a bubble structure substrate containing 5-OHU (preferred substrates for NEIL1 and NEIL2) and by quantitating the cleavage products. Aniline treatment led to a 1.25-fold increase in the NEIL1/2-associated BER activity in the nuclear extracts of spleen compared to the controls. Real-time PCR analysis for NEIL1 and NEIL2 mRNA expression in the spleen revealed 2.7- and 3.9-fold increases, respectively, in aniline-treated rats compared to controls. Likewise, Western blot analysis showed that protein expression of NEIL1 and NEIL2 in the nuclear extract of spleens from aniline-treated rats was 2.0- and 3.8-fold higher than controls, respectively. Aniline treatment also led to stronger immunoreactivity for NEIL1 and NEIL2 in the spleens, confined to the red pulp areas. These studies, thus, show that aniline-induced oxidative stress is associated with an induction of NEIL1/2. The increased NIEL-mediated BER activity is another indication of aniline-induced oxidative damage in the spleen and could constitute another important mechanism of removal of oxidative DNA lesions, especially in transcribed DNA following aniline insult.

60 APPLIED LIFE SCIENCES↗

The production of advanced glass ceramic HLW forms using cold crucible induction melter

Cold Crucible Induction Melters (CCIM) will favorably change how High-Level radioactive Waste (from nuclear fuel recovery) is treated in a near future. Unlike the existing Joule-Heated Melters (JHM) currently in operation for the glass-based immobilization of High-Level Waste (HLW), CCIM offers unique material features that will increase melt temperatures, increase throughput, increase mixing, increase loading in the waste form, lower melter foot prints, eliminate melter corrosion and lower costs. These features not only enhance the technology for producing HLW forms, but also provide advantageous attributes to the waste form by allowing more durable alternatives to glass. It is concluded that glass ceramic waste forms that are tailored to immobilize fission products of HLW can be can be made from the HLW processed with the CCIM. The advantageous higher temperatures reached with the CCIM and unachievable with JHM allows the lanthanides, alkali, alkaline earths, and molybdenum to dissolve into a molten glass. Upon controlled cooling they go into targeted crystalline phases to form a glass ceramic waste form with higher waste loadings than achievable with borosilicate glass waste forms. Natural cooling proves to be too fast for the formation of all targeted crystalline phases.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Partitioning of fission products from irradiated nitride fuel using inductive vaporization

Irradiated nitride fuel (Pu{sub 0.3}Zr{sub 0.7})N fabricated at PSI in frame of the CONFIRM project and having a burn-up of 10.4 % FIMA (Fission per Initial Metal Atom) has been investigated by means of inductive vaporization. The study of thermal stability and release behavior of Pu, Am, Zr and fission products (FPs) was performed in a wide temperature range (up to 2300 C. degrees) and on different redox conditions. On-line monitoring by ICP-MS detected low nitride stability and significant loss of Pu and Am at T>1900 C. degrees during annealing under inert atmosphere (Ar). The oxidative pre-treatment of nitride fuel on air at 1000 C. degrees resulted in strong retention of Pu and Am in the solid, as well as of most FPs. Thermodynamic modelling of elemental speciation using GEM-Selektor v.3 code (Gibbs Energy Minimization Selektor), supported by a comprehensive literature review on thermodynamics of actinides and FPs, revealed a number of binary compounds of Cs, Mo, Te, Sr and Ba to occur in the solid. Speciation of some FPs in the fuel is discussed and compared to earlier results of electron probe microanalysis (EPMA). Predominant vapor species predicted by GEM-Selektor calculations were Pu(g), Am(g) and N{sub 2}. Nitrogen can be completely released from the fuel after complete oxidation at 1000 C. degrees. With regard to the irradiated nitride reprocessing technology, this result can have an important practical application as an alternative way for {sup 15}N recovery. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Iron Phosphate Glass for Vitrifying Hanford AZ102 LAW in Joule Heated and Cold Crucible Induction Melters - 12240

An iron phosphate composition for vitrifying a high sulfate (∼17 wt%) and high alkali (∼80 wt%) Hanford low activity waste (LAW), known as AZ-102 LAW, has been developed for processing in a Joule Heated Melter (JHM) or a Cold Crucible Induction Melter (CCIM). This composition produced a glass waste form, designated as MS26AZ102F-2, with a waste loading of 26 wt% of the AZ-102 which corresponded to a total alkali and sulfate (represented as SO{sub 3}) content of 21 and 4.4 wt%, respectively. A slurry (7 M Na{sup +}) of MS26AZ102F-2 simulant was melted continuously at temperatures between 1030 and 1090 deg. C for 10 days in a small JHM at PNNL and for 70 hours in a CCIM at INL. The as-cast glasses produced in both melters and in trial laboratory experiments along with their canister centerline cooled (CCC) counterparts met the requirements for the Product Consistency Test (PCT) and the Vapor Hydration Test (VHT) responses in the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Contract. These glass waste forms retained up to 77 % of the SO{sub 3} (3.3 wt%), 100% of the Cesium, and 33 to 44% of the rhenium (used as a surrogate for Tc) all of which either exceeded or were comparable to the retention limit for these species in borosilicate glass nuclear waste form. Analyses of commercial K-3 refractory lining and the Inconel 693 metal electrodes used in JHM indicated only minimum corrosion of these components by the iron phosphate glass. This is the first time that an iron phosphate composition was melted continuously in a slurry fed JHM and in the US, thereby, demonstrating that iron phosphate glasses can be used as alternative hosts for vitrifying nuclear waste. The following conclusions are drawn from the results of the present work. (1) An iron phosphate composition, designated as MS26AZ102F-2, containing 26 wt% of the simulated high sulfate (17 wt%), high alkali (80 wt%) Hanford AZ-102 LAW meets all the criteria for processing in a JHM and CCIM. This composition produces a homogeneous glass with a density of 2.80 ± 0.04 g/cm{sup 3} after melting between 1000 and 1050 deg. C for 3 to 5 h. (2) This is the first time that an iron phosphate glass was melted in the JHM continuously for 10 days achieving a specific melting rate of 1010 kg/m2/day and in the CCIM for 70 hrs with a melting rate of 664 kg/m{sup 2}/day. (3) The analyzed (ICP-AES) compositions for all the glasses prepared under several melting conditions are in excellent agreement with the target composition. The variation of melting conditions include: (i) use of small scale/short melting time to large scale/long melting time (300 g to 80 kg, 4 h to 10 days) operations including melting in the JHM and CCIM, (ii) use of dry or wet (slurry) melter feed, (iii) addition of reductant (sugar) in the batch, and (iv) bubbling the melt with air. (4) The chemical durability as measured by PCT and VHT for the quenched and CCC-treated waste forms prepared from laboratory, JHM or CCIM melting exceeds the DOE requirements for LAW. (5) Depending upon the melting time (4 h to 10 days), the average concentration of SO{sub 3} in the MS26AZ102F-2 iron phosphate glass waste form varies from about 1.78 (RSM) to 3.74 (laboratory melt) wt% which corresponds to an SO{sub 3} retention of 41 to 86% when melted between 1030 at 1050 deg. C in air. (6) The retention of SO{sub 3} in the glass was reduced when a reductant (sugar) was added to the slurry. (7) The retention of other problem components like Cesium and Rhenium/Tc-99 is also high; from 92 to 100% for Cs{sub 2}O under different melting conditions, and from 66 to 33% for Re{sub 2}O{sub 7} for melts processed from 3 to 5 hours and up to 10 days. (8) Corrosion tests on Inconel 693 and K-3 refractory at temperatures between 1000 and 1050 deg. C indicate that both materials should be suitable for melting iron phosphate glasses. (9) The viscosity and electrical conductivity of the MS26AZ102F-2 melt are within the acceptable limits for RSM and CCIM processing. (10)This work has shown that iron phosphate compositions are a potential alternative to borosilicate glasses for vitrifying problematic wastes such as Hanford AZ-102 LAW that contains high amounts sulfate and alkali oxides, and that iron phosphate melts such as MS26AZ102F-2 can be processed in the JHM or CCIM. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radiation and Electromagnetic Induction Data Fusion for Detection of Buried Radioactive Metal Waste - 12282

At the United States Army's test sites, fired penetrators made of Depleted Uranium (DU) have been buried under ground and become hazardous waste. Previously, we developed techniques for detecting buried radioactive targets. We also developed approaches for locating buried paramagnetic metal objects by utilizing the electromagnetic induction (EMI) sensor data. In this paper, we apply data fusion techniques to combine results from both the radiation detection and the EMI detection, so that we can further distinguish among DU penetrators, DU oxide, and non- DU metal debris. We develop a two-step fusion approach for the task, and test it with survey data collected on simulation targets. In this work, we explored radiation and EMI data fusion for detecting DU, oxides, and non-DU metals. We developed a two-step fusion approach based on majority voting and a set of decision rules. With this approach, we fuse results from radiation detection based on the RX algorithm and EMI detection based on a 3-step analysis. Our fusion approach has been tested successfully with data collected on simulation targets. In the future, we will need to further verify the effectiveness of this fusion approach with field data. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

UMo Solutions Processing in La Hague Cold Crucible Induction Melter: the Feedback From the First Years of Operation - 16376

250 cubic meters of high-level liquid waste from reprocessed U-Mo-Sn-Al spent fuel, used in Gas Cooled Reactors (GCR), were produced during the mid-1960's at La Hague facility. These 'UMo' solutions are less radioactive than the current fission product concentrates coming from ongoing reprocessing activities, but are very rich in molybdenum and phosphorus whose contents make the molten glass quite corrosive and require a high-temperature glass formulation to obtain sufficiently high waste loading factors (12% in molybdenum oxide). Hence the use of the Cold Crucible Induction Melter (CCIM) technology to process such solutions has been deemed a good opportunity for AREVA to meet its performance expectations. In addition to being very corrosive, the UMo waste is quite challenging to process as the molybdenum has a strong tendency to stick in the calciner and causes clogging issues in off-gas treatment equipment. Therefore, the process and technological qualifications were deployed in order to address these specific issues. UMo solutions processing in the La Hague CCIM has started in January 2013 and is currently ongoing. During this period (from 2013 to 2015), many data have been collected to confirm the process parameters that were defined during the qualification of this innovating process. Even if some difficulties occurred, operations teams experience along with engineering and R and D support allowed managing them. This paper presents the start-up methodology and the feedback from the first years of UMo solutions processing with the CCIM technology at La Hague site. Lessons learned are presented with the difficulties encountered and the solutions implemented, emphasizing the benefits of a close integration between R and D, engineering and operations teams. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

NETEC COLD CRUCIBLE INDUCTION MELTER DEMONSTRATION FOR SRNL WITH SIMULATED SLUDGE BATCH 4 DWPF WASTE

Cold Crucible Induction Melter (CCIM) Technology is being considered as a possible next generation melter for the Defense Waste Processing Facility (DWPF). Initial and baseline demonstrations that vitrified a Sludge Batch 4 (SB4) simulant at a waste loading of 50 weight percent (versus about 38 weight percent in the current DWPF Melter) were performed by the Nuclear Engineering and Technology Institute (NETEC) in South Korea via a subcontract from the Washington Savannah River Company (WSRC). This higher waste loading was achieved by using a CCIM which can run at higher glass processing temperatures (1250 C and higher) than the current DWPF Melter (1150 C). Higher waste loadings would result in less canisters being filled and faster waste throughput at the DWPF. The main demonstration objectives were to determine the maximum melt rate/waste throughput for the NETEC CCIM with a Sludge Batch 4 simulant as well as determine the viability of this technology for use in the DWPF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

GLASS FORMULATION DEVELOPMENT AND TESTING FOR COLD CRUCIBLE INDUCTION MELTER (CCIM) ADVANCED REMEDIATION TECHNOLOGIES DEMONSTRATION PROJECT - 9208

Over the past few years, Cold Crucible Induction Melter (CCIM) demonstrations have been completed using SRS sludge batches 2, 3 and 4 (SB2, SB3 and SB4) simulant compositions. These campaigns demonstrated the ability of the CCIM to effectively produce quality glasses at high waste loadings. The current Advanced Remediation Technology (ART) Phase II-A Project is aimed at demonstrating the CCIM technology under representative DWPF flowsheet conditions and to demonstrate extended operations of the melter. A glass composition development effort was completed to identify and recommend a frit composition and sludge batch 4 (SB4) simulant waste loading target for subsequent ART-Phase II-A CCIM demonstration testing. Based on the results of the glass formulation testing, it was recommended that the Frit 503-R6 composition (B{sub 2}O{sub 3} = 14 wt %; Li{sub 2}O = 9 wt %; Na{sub 2}O = 3 wt %; and SiO{sub 2} = 74 wt %) be utilized for the demonstration. Furthermore, a waste loading of 46 wt % was recommended. The recommended frit and waste loading would produce a glass with acceptable durability with a liquidus temperature adequately below the 1250 C nominal CCIM operating temperature. This frit composition and waste loading was found to result in a glass that met CCIM processing requirements for viscosity, electrical conductivity and thermal conductivity. The recommended frit and waste loading level should also provide a buffer for sludge product compositional variation to support the Phase II-A CCIM demonstration.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Separation of actinides using capillary extraction chromatography-inductively coupled plasma mass spectrometry

Trace levels of actinides have been separated on extraction chromatography columns. Detection of the actinides was achieved using an inductively coupled plasma mass spectrometer (ICP-MS), which was coupled with the extraction chromatography system. In this study we compare 30 cm long, 4.6 mm ID columns to capillary columns (750 {micro}m ID) with lengths from 30 cm up to 150 cm. The columns that were tested were packed with TRU resin. We were able to separate a mixture of five actinides ({sup 232}Th, {sup 238}U, {sup 237}Np, {sup 239}pU, {sup 241}Am). This work has application to rapid bioassay as well as for automated separations of actinide materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-resolved studies of particle effects in laser ablation inductively coupled plasma-mass spectrometry

Time resolved signals in laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) are studied to determine the influence of experimental parameters on ICP-induced fractionation effects. Differences in sample composition and morphology, i.e., ablating brass, glass, or dust pellets, have a profound effect on the time resolved signal. Helium transport gas significantly decreases large positive signal spikes arising from large particles in the ICP. A binder for pellets also reduces the abundance and amplitude of spikes in the signal. MO{sup +} ions also yield signal spikes, but these MO{sup +} spikes generally occur at different times from their atomic ion counterparts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Element for use in an inductive coupler for downhole components

An element for use in an inductive coupler for downhole components comprises an annular housing having a generally circular recess. The element further comprises a plurality of generally linear, magnetically conductive segments. Each segment includes a bottom portion, an inner wall portion, and an outer wall portion. The portions together define a generally linear trough from a first end to a second end of each segment. The segments are arranged adjacent to each other within the housing recess to form a generally circular trough. The ends of at least half of the segments are shaped such that the first end of one of the segments is complementary in form to the second end of an adjacent segment. In one embodiment, all of the ends are angled. Preferably, the first ends are angled with the same angle and the second ends are angled with the complementary angle.

47 OTHER INSTRUMENTATION↗

Methods for detecting and correcting inaccurate results in inductively coupled plasma-atomic emission spectrometry

A method for detecting and correcting inaccurate results in inductively coupled plasma-atomic emission spectrometry (ICP-AES). ICP-AES analysis is performed across a plurality of selected locations in the plasma on an unknown sample, collecting the light intensity at one or more selected wavelengths of one or more sought-for analytes, creating a first dataset. The first dataset is then calibrated with a calibration dataset creating a calibrated first dataset curve. If the calibrated first dataset curve has a variability along the location within the plasma for a selected wavelength, errors are present. Plasma-related errors are then corrected by diluting the unknown sample and performing the same ICP-AES analysis on the diluted unknown sample creating a calibrated second dataset curve (accounting for the dilution) for the one or more sought-for analytes. The cross-over point of the calibrated dataset curves yields the corrected value (free from plasma related errors) for each sought-for analyte.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗