Search NASA⌕ Search

SEARCH · Search NASA

Results for “ION IMPLANTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Dependence of the half-life of {sup 221}Fr on the implantation environment

The possible dependence of the half-life of {sup 221}Fr on the solid-state environment has been investigated by the simultaneous measurement of implanted {sup 221}Fr ions in an insulator (Si) and a metallic substrate (Au) at the ISOLDE facility at CERN. Our results indicate that, if existing, the difference in half-life does not follow a systematic trend and it is well below 1%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electrical activation and electron spin resonance measurements of arsenic implanted in silicon

The electrical activation of arsenic (As) implanted in Si is investigated with electron spin resonance (ESR), spreading resistance (SR), and secondary ion mass spectroscopy (SIMS). The As ions were implanted with a dose of 1 × 10{sup 12 }cm{sup −2} and subsequently annealed at various temperatures in the range of 500–1100 °C. The ESR measurements at 10 K show that the density of the As donor electrons for all the annealing temperatures is less than 10% of the As atom concentration measured by SIMS. The SR data indicate that the density of conduction band electrons is several times larger than that of the As donor electrons. These results strongly suggest that most of the As donor electrons are ESR inactive at low temperatures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Site specific isolated nanostructure array formation on a large area by broad ion beam without any mask and resist

We report the formation of isolated nanostructure arrays on a large area via broad ion beam implantation without the aid of any mask or resist. Desired ions have been implanted at specific locations of the prefabricated silicon ripple or triangular structures by exploiting the variation of local ion impact angles. We have shown that the implantation of Fe ions on an O{sup +} ions induced pre fabricated triangular shaped patterned Si surface results in a self-organized periodic array of striped magnetic nanostructures having several micron length and about 50 nm width arranged with a spacial separation of ∼200 nm. The morphology, composition, crystalline structure, and magnetic property of these nanopatterns have been analyzed using high-resolution cross-sectional transmission electron microscopy and atomic force microscopy. A geometrical model has been proposed to explain the fundamental features of such ion-induced nanopattern structures.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Conformal Doping of FINFETs: a Fabrication and Metrology Challenge

Whereas the introduction of 3D-dimensional devices such as FINFETs may be a solution for next generation technologies, they do represent significant challenges with respect to the doping strategies and the junction characterization. Aiming at a conformal doping, classical beam implants fail due to the differences in impact angle, ion incorporation efficiency and the effect of wafer rotation. Moreover shadowing represents an additional limitation for larger tilt angles when considering closely spaced FINs. Plasma immersion doping is an alternative approach which holds the promise of conformality but is also quite challenging and relies on secondary processes such as resputtering, deposition and in diffusion etc. Its implementation is compromised by concurrent artifacts, sputter erosion being the most important one. In support of these developments the measurement of the 3D-dopant distribution and the identification of conformality is essential requiring adequate metrology such as Scanning Spreading Resistance Microscopy, SIMS through FINs, resistors and the Tomographic Atomprobe.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Distribution of species and Ga–N bonds in silicon co-implanted with gallium and nitrogen ions

The concentration profiles of species in silicon subjected to gallium and nitrogen co-implantation and subsequent annealing have been investigated by the method of X-ray photoelectron spectroscopy combined with the layer-by-layer ion etching of the implanted layer. It is shown that practically entire implanted gallium undergoes out-diffusion, but the preliminary implantation of nitrogen for the synthesis of a barrier SiN{sub x} layer makes it possible to avoid the essential loss of gallium. In this case, about 14 % of implanted gallium bond to nitrogen. The obtained data are discussed from the viewpoint of the possibility of ion synthesis of GaN inclusions in silicon matrix.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Influence of ion source configuration and its operation parameters on the target sputtering and implantation process

In the work, investigation of the features and operation regimes of sputter enhanced ion-plasma source are presented. The source is based on the target sputtering with the dense plasma formed in the crossed electric and magnetic fields. It allows operation with noble or reactive gases at low pressure discharge regimes, and, the resulting ion beam is the mixture of ions from the working gas and sputtering target. Any conductive material, such as metals, alloys, or compounds, can be used as the sputtering target. Effectiveness of target sputtering process with the plasma was investigated dependently on the gun geometry, plasma parameters, and the target bias voltage. With the applied accelerating voltage from 0 to 20 kV, the source can be operated in regimes of thin film deposition, ion-beam mixing, and ion implantation. Multi-component ion beam implantation was applied to {alpha}-Fe, which leads to the surface hardness increasing from 2 GPa in the initial condition up to 3.5 GPa in case of combined N{sub 2}-C implantation. Projected range of the implanted elements is up to 20 nm with the implantation energy 20 keV that was obtained with XPS depth profiling.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modification of the crystal structure of gadolinium gallium garnet by helium ion irradiation

The structure of gadolinium gallium garnet (GGG) single crystals before and after implantation by He{sup +} ions has been investigated using high-resolution X-ray diffraction methods and the generalized dynamic theory of X-ray scattering. The main types of growth defects in GGG single crystals and radiation-induced defects in the ion-implanted layer have been determined. It is established that the concentration of dislocation loops in the GGG surface layer modified by ion implantation increases and their radius decreases with an increase in the implantation dose.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of surface texture by ion beam sputtering on implant biocompatibility and soft tissue attachment

The objectives in this report were to use the ion beam sputtering technique to produce surface textures on polymers, metals, and ceramics. The morphology of the texture was altered by varying both the width and depth of the square pits which were formed by ion beam erosion. The width of the ribs separating the pits were defined by the mask used to produce the texture. The area of the surface containing pits varies as the width was changed. The biological parameters used to evaluate the biological response to the texture were: (1) fibrous capsule and inflammatory response in subcutaneous soft tissue; (2) strength of the mechanical attachment of the textured surface by the soft tissue; and (3) morphology of the epidermal layer interfacing the textured surface of percutaneous connectors. Because the sputter yield on teflon ribs was approximately an order of magnitude larger than any other material the majority of the measurements presented in the report were obtained with teflon.

Gibbons, D. F.↗

GaAs/GaAlAs distributed Bragg reflector laser with a focused ion beam, low dose dopant implanted grating

The performance of a GaAs/GaAlAs distributed Bragg reflector (DBR) laser using a focused ion beam implanted grating (FIB-DBR) is reported for the first time. Stripes of Si(2+) with a period of 2300 A and a dose about 10 to the 14th/sq cm are directly implanted into the passive large optical cavity layer to provide the distributed feedback. Surface-emitting light from the second-order grating is observed. Threshold current of 110 mA and single DBR mode operation from 20 to 40 C are obtained. The wavelength tuning rate with temperature is 0.8 A/C. The coupling coefficient is estimated to be 15/cm. The results show that FIB technology is practical for distributed feedback and DBR lasers and optoelectronic integrated circuits.

Wu, M. C.↗

Extremely large d 0 magnetism in krypton implanted polar ZnO films

Magnetization is produced in samples of ZnO by implanting krypton ions. Krypton is chemically inert; hence, the magnetization is the consequence of the radiation damage that occurred due to the implantation process. We have found magnetization as large as 185 emu cm –3 at room temperature which corresponds to a moment of ~40 Bohr magnetons per implanted krypton ion. The results are compared for implantation into different ZnO samples, O- and Zn-polar thin films and thin ZnO crystal wafers. The structure of the films has been investigated using RHEED, AFM, XRD and EXAFS. The O-polar film grew in a layer-by-layer mode and after implantation, its lattice spacing increased and the grain size decreased which indicated that the Kr atoms had been incorporated into the lattice. In contrast the Zn-polar film grew in a Stranski–Krastanov mode and its lattice spacing and grain size were almost unchanged by the implantation indicating that the Kr atoms were in the grain boundaries. Raman scattering is used to characterize the radiation damage and to identify scattering from amorphous regions in the grain boundaries and the scattering from point defects. The largest magnetization is found in the O-polar ZnO films where there is a marked grain fragmentation, leading to an increase in the volume of the sample occupied by grain boundaries. As a result, the increase in the number of point defects, which was identified by Raman scattering for films of both polarity, was less effective at producing a magnetic signal than the grain boundaries.

36 MATERIALS SCIENCE↗

An origin of orange (2 eV) photoluminescence in SiO{sub 2} films implanted with high Si{sup +}-ion doses

The photoluminescence and photoluminescence excitation spectra of SiO{sub 2} films implanted with high (3 at %) Si{sup +}-ion doses are studied in relation to the temperature of postimplantation annealing. It is shown that two photoluminescence bands with peaks at 2.7 and 2 eV are dominant in the spectra. As the annealing temperature is increased, the relation between the intensities of the 2.7 and 2 eV bands changes in favor of the former one. Both of the photoluminescence bands have their main excitation peak at the energy 5.1 eV. The excitation spectrum of the ∼2-eV band exhibits also peaks at 3.8 and 4.6 eV. It is concluded that, in the implanted SiO{sub 2} films, the orange photoluminescence band originates from radiative transitions between levels of centers associated with a deficiency of oxygen (≡Si–Si≡ or =Si:) and the levels of nonbridging oxygen (≡Si–O•)

36 MATERIALS SCIENCE↗

Ion beam synthesis of ZrC{sub x}O{sub y} nanoparticles in cubic zirconia

{110}-oriented yttria-stabilized zirconia single crystals have been implanted with low-energy C ions in an axial direction, at room temperature and at 550 °C. Room temperature ion implantation generated a damage layer that contains the expected dislocation loop clusters. Strikingly, the high temperature implantation produced zirconium oxycarbide nanoparticles (ZrC{sub x}O{sub y}) at a shallow depth in the yttria-stabilized cubic zirconia crystal, with a diameter in the range of 4–10 nm. Moreover, in the high concentration region of implanted C ions, between 100 and 150 nm below the surface, a number of large precipitates, up to 20 nm, were observed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SIMS/ARXPS - A New Technique of Retained Dopant Dose and Profile Measurement of Low Energy Doping Processes

A newly-developed surface analysis technique, which combines Secondary Ion Mass Spectrometry (SIMS) with Angle-Resolved X-ray Photoelectron Spectroscopy (ARXPS), was used to achieve more accurate results of the retained impurity doses and profiles for ultra-low energy implants, including conventional beam-line implant and plasma immersion ion implantation (PIII). Using this method, it has been found that the B{sub 2}H{sub 6}(Diborane) PIII demonstrates thicker native oxide and much more B dose loss during RTP and surface clean treatments than conventional beam-line ion implantation, due to the higher surface B concentration. In order to match the electrical parameters of the device, PIII must consider higher nominal dose to compensate the B loss.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Compositional and Structural Study of Gd Implanted ZnO Films

We report a compositional and structural study of ZnO films implanted with 30 keV Gd ions. The depth profile of the implanted ions, measured by Rutherford backscattering spectrometry, matches predictions of DYNAMIC-TRIM calculations. However, after annealing at temperatures above 550 deg. C the Gd ions are observed to migrate towards the bulk, and at the same time atomic force microscope images of the film surfaces show significant roughening. Raman spectroscopy shows that the annealed films have a reduced number of crystalline defects. The overall results are useful for developing an implantation-annealing regime to produce well characterized samples to investigate magnetism in the ZnO:Gd system.

36 MATERIALS SCIENCE↗

On the origins of trapped helium, neon and argon isotopic variations in meteorites. I - Gas-rich meteorites, lunar soil and breccia. II - Carbonaceous meteorites.

Data are presented from stepwise heating experiments and total extractions on five meteorites: Kapoeta, Fayetteville, Holman Island, Cee Vee, and Pultusk. These data reveal the presence of four isotopically distinct trapped neon components. A comparison of trapped neon with trapped helium and argon in bulk analyses indicates the existence of correlated helium, neon and argon isotopic structures. Component B is attributed primarily to direct implantation of rare gas ions by the present day solar wind. Component C is identified with directly implanted low energy (1-10 Mev/n) solar flare rare gases. Component D is associated with rare gas ions implanted in meteoritic material by the primitive, pre-main sequence, solar wind. A fourth component, observed only in Kapoeta and the lunar fines and breccia, is tentatively attributed to parent body 'atmospheric' ions implanted in surface material by a solar wind induced electric field.

Black, D. C.↗

Positron annihilation studies of fluorine-vacancy complexes in Si and SiGe

The formation of fluorine-vacancy (FV) complexes in strained Si-SiGe-Si multilayer structures and relaxed SiGe layers of varying Ge content has been investigated using variable-energy positron annihilation spectroscopy, including Doppler-broadened spectra ratio curves. It has been found that in all sample types there are two distinct regions defined only by the damage created by the implanted F ions. The first, shallower region (from the surface to a depth of {approx}200 nm) was found to contain a mixture of undecorated vacancies and FV complexes; there is no correlation between the vacancy or F concentration in this region and the Ge content. The multi-layer samples may also have O contamination that is not present in the relaxed samples. The second region (at depths {approx}200-440 nm) contains primarily FV complexes in all samples. In the multi-layer samples secondary ion mass spectrometry (SIMS) results show peaks of F accumulating in, or at the interfaces of, each SiGe multi-layer; the FV complexes, however, are distributed over depths similar to those in the relaxed samples, with some localization at the SiGe layer located within the second region. The positron response is primarily to FV complexes formed by the F implant in all samples. The F: FV ratios are approximately 3-7: 1 in the relaxed samples. Positrons appear to be relatively insensitive to the largest of the F SIMS peaks which lies beyond the second region. This is probably because the F has filled all the open volume at the SiGe layer, leaving no positron trapping sites.

36 MATERIALS SCIENCE↗

Characteristics of ZnO Wafers Implanted with 60 keV Sn{sup +} Ions at Room Temperature and at 110 K

ZnO wafers implanted with 60 keV Sn{sup +} ions at room temperature (RT) and at 110 K are investigated by means of X-ray diffraction (XRD) and photoluminescence (PL) techniques. The effect of implantation temperature is evident in the XRD and PL data. A yellow-orange (YO) band near 600 nm appears in the PL spectra of the ZnO wafers implanted to the doses of 4x10{sup 14} and 8x10{sup 14} ions/cm{sup 2} at RT. The intensity of this band increases and the peak position blue-shifts after illumination of the samples with the 325 nm line of a He-Cd laser. The PL data suggests that the CB (conduction band){yields}V{sub O}{sup +} and Zn{sub i}{sup +{yields}}V{sub Zn}{sup -} transitions contribute to the photoemission of the YO band.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

MIAMI: Microscope and ion accelerator for materials investigations

A transmission electron microscope (TEM) with in situ ion irradiation has been built at the University of Salford, U.K. The system consists of a Colutron G-2 ion source connected to a JEOL JEM-2000FX TEM via an in-house designed and constructed ion beam transport system. The ion source can deliver ion energies from 0.5 to 10 keV for singly charged ions and can be floated up to 100 kV to allow acceleration to higher energies. Ion species from H to Xe can be produced for the full range of energies allowing the investigation of implantation with light ions such as helium as well as the effects of displacing irradiation with heavy inert or self-ions. The ability to implant light ions at energies low enough such that they come to rest within the thickness of a TEM sample and to also irradiate with heavier species at energies sufficient to cause large numbers of atomic displacements makes this facility ideally suited to the study of materials for use in nuclear environments. TEM allows the internal microstructure of a sample to be imaged at the nanoscale. By irradiating in situ it is possible to observe the dynamic evolution of radiation damage which can occur during irradiation as a result of competing processes within the system being studied. Furthermore, experimental variables such as temperature can be controlled and maintained throughout both irradiation and observation. This combination of capabilities enables an understanding of the underlying atomistic processes to be gained and thus gives invaluable insights into the fundamental physics governing the response of materials to irradiation. Details of the design and specifications of the MIAMI facility are given along with examples of initial experimental results in silicon and silicon carbide.

36 MATERIALS SCIENCE↗