Search NASA⌕ Search

SEARCH · Search NASA

Results for “Impact loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Impact of Biofuel Blending on Hydrocarbon Speciation and Particulate Matter from a Medium-Duty Multimode Combustion Strategy

The U.S. Department of Energy’s Co-Optima initiative simultaneous focused on diversifying fuel sources, improving efficiency, and reducing emissions through using novel combustion strategies and sustainable fuel blends. For medium-duty/heavy-duty diesel engines, research in this area has led to the development of a multimode strategy that uses premixed charge compression ignition (PCCI) at low loads and conventional diesel combustion (CDC) at mid–high loads. The aim of this study was to understand how emissions were impacted when using PCCI instead of CDC at low loads and switching to an oxygenated biofuel blend. It provides a detailed speciation of the hydrocarbon (HC) and particulate matter (PM) emissions from a multimode medium-duty engine operating at low loads in PCCI and CDC modes and high loads in CDC. The effect of the oxygenated biofuel blend on emissions was studied at all three mode–load conditions using #2 ULSD and a bio-derived fuel (25% hexyl hexanoate (HHN)) blended in #2 ULSD. The PCCI mode effectively decreased NOx, total HC, and PM/PN emissions, with a substantial decrease in larger particles (≥50 nm). A PM/PN reduction was observed at high loads with the 25% HHN fuel. While the total HC emissions were not impacted by fuel type, the detailed HC analysis exposed changes in the HC’s composition.

09 BIOMASS FUELS↗

Integrated Two-Stage Alkaline-Oxidative Pretreatment of Hybrid Poplar. Part 1: Impact of Alkaline Pre-Extraction Conditions on Process Performance and Lignin Properties

We previously demonstrated that a two-stage pretreatment comprising of an alkaline pre-extraction followed by a Cu-catalyzed alkaline–oxidative treatment is effective at pretreating hardwoods under relatively mild reaction conditions. In this work, we focus on characterizing how biomass source and reaction conditions used during the alkaline pre-extraction impact the subsequent processing stages as well as lignin yields and properties. Specifically, three hybrid poplars were subjected to the first stage alkaline pre-extraction under various conditions including differences in time (15–300 min), temperature (95–155 °C), and alkali loadings (50–200 mg NaOH/g biomass), and the impact on total mass solubilization, lignin recovery, and lignin purity was determined. Empirical correlations were developed between reaction conditions and mass solubilization and lignin recovery during the pre-extraction stage. For select conditions, lignin properties were assessed and include β-O-4 content determined by 13C NMR, molecular mass distributions as determined by gel permeation chromatography, and susceptibility to depolymerization to aromatic monomers using thioacidolysis and formic acid catalyzed depolymerization. We found alkaline pre-extraction performed at higher temperatures generated lignins exhibiting lower contamination by polysaccharides, lower aromatic monomer yields from depolymerization, lower molar masses, and lower β-O-4 contents relative to the lower temperature pre-extractions. Lastly, the pre-extracted biomass from select conditions was assessed for its response to the subsequent Cu-catalyzed alkaline–oxidative treatment and enzymatic hydrolysis. It was demonstrated that minor differences in delignification during pre-extraction have quantifiable impacts on the subsequent efficacy of the second stage of pretreatment and enzymatic hydrolysis with improved lignin removal during the first pre-extraction stage resulting in improved hydrolysis yields.

09 BIOMASS FUELS↗

Role of initial conditions in plasma-current coupling of gas-puff Z-pinches

Azimuthal magnetic field measurements obtained during the implosion phase of an oxygen gas-puff Z-pinch on a 500 kA peak current and 180 ns rise time linear transformer driver are presented. While a fraction of the driver current was measured within the imploding plasma, key initial conditions were found to significantly impact the delivery of current to the plasma load. The electrode geometry was modified to assist the initial dielectric breakdown and resulted in improved shot reproducibility. Optimization of the gas injection plenum pressure and timing resulted in an increase in the current coupling parameter, defined as the ratio of the measured value of $B$ $θ$ to the expected value, from 50% to 75%. Furthermore, the degree of radial expansion of the gas puff in the load region, which is suspected to lead to the observed current loss during the implosion, was reduced by shortening the valve opening duration. Additionally, a pre-embedded axial magnetic field of up to 0.2 T was found to have no significant impact on the plasma-current coupling of the oxygen implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Decarbonization of Residential Building Energy Supply: Impact of Cogeneration System Performance on Energy, Environment, and Economics

Electrical and thermal loads of residential buildings present a unique opportunity for onsite power generation, and concomitant thermal energy generation, storage, and utilization, to decrease primary energy consumption and carbon dioxide intensity. This approach also improves resiliency and ability to address peak load burden effectively. Demand response programs and grid-interactive buildings are also essential to meet the energy needs of the 21st century while addressing climate impact. Given the significance of the scale of building energy consumption, this study investigates how cogeneration systems influence the primary energy consumption and carbon footprint in residential buildings. The impact of onsite power generation capacity, its electrical and thermal efficiency, and its cost, on total primary energy consumption, equivalent carbon dioxide emissions, operating expenditure, and, most importantly, thermal and electrical energy balance, is presented. The conditions at which a cogeneration approach loses its advantage as an energy efficient residential resource are identified as a function of electrical grid’s carbon footprint and primary energy efficiency. Compared to a heat pump heating system with a coefficient of performance (COP) of three, a 0.5 kW cogeneration system with 40% electrical efficiency is shown to lose its environmental benefit if the electrical grid’s carbon dioxide intensity falls below 0.4 kg CO 2 per kWh electricity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Plasma Drag Hypervelocity Particle Accelerator (HYPER)

Current debris models are able to predict the growth of the space debris problem and suggest that spacecraft must employ armor or bumper shields for some orbital altitudes now and that the problem will become worse as a function of time. The practical upper limit to the velocity distribution is on the order of 40 km/s and is associated with the natural environment. The velocity distribution of the man-made component peaks at 9-10 km/s with maximum velocity in the 14-16 km/s range. Experience in space has verified that the "high probability of impact" particles are in the microgram to milligram range. These particles can have very significant effects on coatings, insulators, and thin metallic layers. The surface of thick materials becomes pitted and the local debris component is enhanced by ejecta from the impact events. In this paper, the HYPER facility is described which produces a reasonable simulation of the man-made space debris spectrum in a controlled environment. The facility capability is discussed in terms of drive geometry, energetics, velocity distribution, diagnostics, and projectile/debris loading. The facility has been used to study impact phenomena on Space Station Freedom's solar array structure, the calibration of space debris collectors, other solar array materials, potential structural materials for use in space, electrical breakdown in the space environment, and as a means of clarifying or duplicating the impact phenomena on surfaces which have been exposed in space.

Best, Steve R.↗

Quantifying the Effect of Economic Development Zones on Electrical Load Growth in Kentucky [Slides]

The Kentucky Energy and Environment Cabinet has recently undertaken a comprehensive effort to map and catalog potential economic development sites across the state. The purpose of this technical assistance is to quantify the potential impact of developing designated sites on Kentucky's electricity load growth, providing insights at both state and county level considering the next 10 years. This analysis should explicitly incorporate and address key project uncertainties by developing various load growth scenarios that account for development scale, site specificity, and sector variability. The need for a site-specific analysis comes from the understanding that conventional econometric (top-down) load forecasting models cannot sufficiently isolate or predict the discrete load increases resulting from the development of these unique and targeted economic sites.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Structural load control during construction

In the absence of gravitational pull, the major design considerations for large space structures are stiffness for controllability, and transient dynamic loadings (as opposed to the traditional static load associated with earth-based structures). Because of the absence of gravitational loading, space structures can be designed to be significantly lighter than their counterparts on Earth. For example, the Space Shuttle manipulator arm is capable of moving and positioning a 60,000 lb payload, yet weighs less than 1,000 lbs. A recent design for the Space Station which had a total weight of about 500,000 lbs. used a primary loadcarrying keel beam which weighed less than 10,000 lbs. For many large space structures designs it is quite common for the load-carrying structure to have a mass fraction on the order of one or two percent of the total spacecraft mass. This significant weight reduction for large space structures is commonly accompanied by very low natural frequencies. These low frequencies cause an unprecedented level of operational complexity for mission applications which require a high level of positioning and control accuracy. This control problem is currently the subject of considerable research directed towards reducing the flexibility problem. In addition, however, the small mass fraction typically results in structures which are quite unforgiving to inadvertent high loadings. In other words, the structures are 'fragile.' In order to deal with the fragility issue CSC developed a load-limiting concept for space truss structures. This concept is aimed at limiting the levels of load which can occur in a large space structure during the construction process as well as during subsequent operations. Currently, the approach for dealing with large loadings is to make the structure larger. The impact this has on construction is significant. The larger structures are more difficult to package in the launch vehicle, and in fact in some instances the concept must be changed from a deployable truss to an erectable truss to permit packaging. The new load-limiting concept is aimed at permitting the use in large space structures of smaller trusses with a high level of strength robustness, in order to simplify the construction process. To date several analyses conducted on the concept have demonstrated its feasibility, and an experiment is currently being designed to demonstrate its operation.

Mikulas, Martin M., Jr.↗

Plug Load Management System Field Study: Wireless Meter and Controls

This presentation offers background on GSA's Green Proving Ground (GPG) and DOE's High Impact Technology (HIT) Catalyst work, and a field study that assessed a plug load management (PLM) system in two commercial building applications. The Ibis InteliNetwork (TM) PLM system enables users to measure and analyze device energy use and identify opportunities for reduction of plug load energy use, and set times for individual devices (or groups of devices) to turn off when not in use. The presentation gives an overview of the PLM demonstration project, its results, and lessons learned.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Multi-Model Framework for Assessing Long- and Short-Term Climate Influences on the Electric Grid

Climate change influences many aspects of the electric grid, but prior work and industry practices often ignore the potential effects of changing climate, or they only consider a single effect or individual effects in isolation. Challenges vary with each grid and include adapting to long-term trends such as changing temperature and precipitation or shorter-term events such as drought or storms that could increase in frequency or intensity. Here we present a multi-model framework designed to analyze the effects of long and short-term climate impacts in combination. This framework couples capacity expansion and production cost models with hydrologic models and future climate scenario data to analyze alternative climate and energy futures at high spatial, temporal, and process resolutions. Furthermore, we constructed and evaluated the results of a suite of simulated scenarios exploring climate impacts on capacity investment and stress-tested the resulting future infrastructures using hourly dispatch modeling under alternative drought and load conditions. We demonstrate the approach through a case study of the U.S. Western Interconnection, where climate impacts depend on interactions between temperature-induced load, water availability for hydropower, technology competitiveness, and demand flexibility. Changes in 2038 generating capacity range from -8.5-16.6 GW, and changes in 2038 transmission capacity range from -1-2 GW. Capacity increases are driven by higher load from higher temperatures, while capacity reductions can be achieved in scenarios with higher future hydropower availability and increased demand flexibility. Scenarios requiring additional capacity cost an additional $\$5$-$\$17$ billion (discounted) from 2018 to 2038; however, scenarios with capacity reductions cost $\$1$-$\$18$ billion less. Stress tests on four 2038 infrastructures demonstrated that the identified systems were able to serve at least 99.999% of load and 99.96% of reserves. However, drought and unexpected high-load conditions can result in reduced capacity to respond to contingency events we did not model. Although these results are system and scenario specific, they highlight the importance of considering multiple climate change impacts simultaneously in long-term planning efforts and demonstrate a multi-model, multiscale approach that can be flexibly applied to any system and set of climate change concerns.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High velocity impact of an Fe/Cr/Mn/Ni high entropy alloy

A series of shock loading experiments were conducted on High Entropy Alloy (HEA) samples consisting of Fe/Cr/Mn/Ni in weight percentages of 25.2/23.5/24.8/26.5. Characterizing this transition metal alloy is a first step in understanding the shock compression response of this relatively new class of alloy. A single stage light gas gun was used to conduct a series of flyer plate symmetric impact experiments to obtain fundamental dynamic properties. Photonic Doppler Velocimetry (PDV) diagnostics were employed to measure the free surface velocity on the back of each target during dynamic compression. These experiments yielded four data points that are in reasonable agreement with an estimated Hugoniot for the material.

36 MATERIALS SCIENCE↗

The impact of chromium coatings on Zircaloy cladding deformation behavior under reactivity-initiated accident-like mechanical loading conditions

A reactivity-initiated accident (RIA) occurs when a control rod ejection or control blade drop causes an increase in the fission rate. The injection of energy results in an increase in fuel temperature which in turn causes rapid thermal expansion of the fuel pellet. This thermal expansion may result in pellet-cladding mechanical interaction (PCMI) in which the fuel imparts a mechanical strain to the cladding. PCMI may cause the cladding to fail, and thus, the mechanical response of cladding due to PCMI must be investigated when characterizing new cladding materials. Chromium-coated Zircaloy-4 is a near-term accident-tolerant fuel cladding that exhibits improved high-temperature oxidation resistance. Modified burst testing was utilized to experimentally simulate the effects of PCMI on both uncoated and chromium-coated Zircaloy cladding samples at hot zero power conditions. Samples were coated using either cold spraying or physical vapor deposition to understand the differences in behavior that the coating application method may cause. Digital image correlation was used to analyze images of the deforming specimens to extract the in-situ strain behavior of the cladding. The uncoated specimens burst at hoop strains ranging from 8.8 % to 17.2 %. The cold-spray chromium-coated Zircaloy specimens burst at hoop strains of 7.0 % to 11.0 %. The physical vapor deposition coated tubes burst at hoop strains of 9.1 % to 11.5 %. These results indicate that the chromium coating causes a loss in the ductility of the cladding. Furthermore, the higher burst hoop strains of the physical vapor deposition-coated samples relative to the cold-spray samples indicate that the cold-spraying technique causes more of a loss in ductility than physical vapor deposition. All samples burst at higher hoop strains than those expected to occur in an RIA for fresh cladding.

Accident-tolerant fuel↗

Shock initiation of nano-Al/Teflon: High dynamic range pyrometry measurements

In this paper, laser-launched flyer plates (25 μm thick Cu) were used to impact-initiate reactive materials consisting of 40 nm Al particles embedded in Teflon AF polymer (Al/Teflon) on sapphire substrates at a stoichiometric concentration (2.3:1 Teflon:Al), as well as one-half and one-fourth that concentration. A high dynamic range emission spectrometer was used to time and spectrally resolve the emitted light and to determine graybody temperature histories with nanosecond time resolution. At 0.5 km s -1 , first light emission was observed from Teflon, but at 0.6 km s -1 , the emission from Al/Teflon became much more intense, so we assigned the impact threshold for Al/Teflon reactions to be 0.6 (±0.1) km s -1 . The flyer plates produced a 7 ns duration steady shock drive. Emission from shocked Al/Teflon above threshold consisted of two bursts. At the higher impact velocities, the first burst started 15 ns after impact, peaked at 25 ns, and persisted for 75 ns. The second burst started at a few hundred nanoseconds and lasted until 2 μs. The 15 ns start time was exactly the time the flyer plate velocity dropped to zero after impact with sapphire. The first burst was associated with shock-triggered reactions and the second, occurring at ambient pressure, was associated with combustion of leftover material that did not react during shock. The emission spectrum was found to be a good fit to a graybody at all times, allowing temperature histories to be extracted. At 25 ns, the temperature at 0.7 km s -1 and the one-fourth Al load was 3800 K. Those temperatures increased significantly with impact velocity, up to 4600 K, but did not increase as much with Al load. A steady combustion process at 2800 (±100) K was observed in the microsecond range. Finally, the minimal dependence on Al loading indicates that these peak temperatures arise primarily from Al nanoparticles reacting almost independently, since the presence of nearby heat sources had little influence on the peak temperatures.

36 MATERIALS SCIENCE↗

Shock Response of Polymethyl Methacrylate (PMMA) Under Explosive Loading

Abstract The dynamic response of polymethyl methacrylate (PMMA) is well understood for one-dimensional planar impact shocks, but limited research has been performed on the response of PMMA under spherical shock loading. In this work, the shock decay of an explosively-driven shock wave into PMMA was experimentally measured. PMMA cubes of various geometries were explosively loaded with an RP-80 detonator to produce the explosive shock wave. High-speed schlieren imaging was implemented to measure the explosively-driven shock wave velocity throughout the PMMA cubes. Photon Doppler velocimetry (PDV) was used to measure the particle velocity imparted by the shock wave at the surface of the cubes. The material shock response was studied at distances from 21.91 to 133.3 mm from the explosive source. The particle velocity history measured by PDV was compared to the wave profile visualized in the high-speed images. The shock wave pulse amplitude decreased with increased distance from the source. The conducted experiments extend the PMMA shock Hugoniot relating to the lower shock and particle velocity regime.

Torres, S. M. (ORCID:0009000287177206)↗

Long-Term Assessment of Commercial Building Energy and Carbon Emissions in the Northwestern Region Under Future Weather Trend

The future climate significantly impacts building performance and increases uncertainties in energy simulations. A rising temperature trend is expected to heighten cooling loads during summer and result in more carbon emissions. Understanding the impact of future climate on building performance is significant for policymakers to make informed decisions. Building retrofit measures can improve building energy efficiency and reduce operational carbon emissions, yet their effects under future climate conditions have not been fully investigated so far. Thus, we proposed an assessment methodology for evaluating long-term energy consumption and operational carbon reduction potential using a building stock dataset. For this study, commercial buildings in the northwestern (NW) region were utilized to assess the impacts of future climate and building retrofit. In addition, we selected Montana with a cold and dry climate as an example to analyze and discuss the carbon emission reduction potential in buildings. The main findings are: (1) Under future climate trends, changes in energy use intensity (EUI) will fluctuate due to variations in heating and cooling degree-days (HDDs and CDDs) and increasing HDDs will lead to increasing EUI. (2) After applying annual building retrofitting, the long-term EUI reduction potential of buildings in the NW region will decrease with the increasing retrofitting degree, and the short-term EUI reduction potential will be impacted by the change of heating and cooling degree days. (3) In Montana, the long-term carbon intensity reduction potential of retrofitted buildings will decrease under future climate trends with the increasing renewable energy penetration.

building energy modeling↗

Creating a Virtual Utility District: Assessing Quality and Building Energy Impacts of Microclimate Simulations

Buildings in China, India, the United States (US), and United Kingdom (UK) consume 39-45% of each nation's primary energy with fast-growing countries like India projected to use 76% of their primary energy by 2040. In the United States, 73% of all electricity is consumed by buildings. In an effort to better operate electrical grids, needs exist to generate improved load models by better understanding and quantifying weather impacts and microclimate effects on building-specific energy use throughout a city.Scalable methods have been created to allow urban-scale energy modeling – to identify and synthesize a fully-articulated building energy model for every building in an area of interest. This was applied to the 1,385 km2 utility district serviced by the Electric Power Board of Chattanooga, TN. Each building is simulated on the world’s 4th-fastest supercomputer, Titan, using the U.S. Dept. of Energy’s flagship whole-building simulation tool, EnergyPlus, to analyze relationships among climatic conditions, urban morphology, land cover, and energy use. The Weather Research Forecast (WRF) model was scaled on several High Performance Computing (HPC) resources to simulate microclimate variation under different urban morphologies. We analyze the differences between WRF-based microclimate simulations and measured weather station data. This information is then used to quantify impact of microclimate variation and variable-specific meteorological variables on the electrical consumption for individual buildings and show impacts at the scale of a utility district.

New, Joshua↗

Reinforced Concrete Fracture Diagnostics under Conditions of Bending by Parameters of the Electric Response to an Impact Action

Regularities of changes in the stress-strain state of reinforced concrete in the process of testing for four-point bending have been studied. The change in characteristics of the electric response to an impact action in the process of a sequential increase in the external load has been analyzed. Regularities in the relation between parameters of the electric response to the impact action and stages of the stress-strain state of reinforced beams in the process of bending have been revealed. Criteria of determining stages of reinforced beam destruction by parameters of the electric response are proposed.

36 MATERIALS SCIENCE↗

Parasitic Capacitors' Impact on Switching Performance in a 10 kV SiC MOSFET Based Converter

In a converter based on 10 kV SiC MOSFETs, major sources of parasitic capacitance are the anti-parallel junction barrier schottky (JBS) diode, heat sink, and load inductor. A half bridge phase leg test setup is built to investigate these parasitic capacitors’ impact on the switching performance at 6.25 kV. Generally these parasitic capacitors slows down both turn-on and turn-off transient and can cause significant increase in switching energy loss. The impact of the parasitic capacitor in the load inductor is analyzed, which has either very short wire or long wire in series. Switching performance of the phase leg with two different thermal designs are compared to investigate the impact of the parasitic capacitor due to the heat sink. The large parasitic capacitor due to the large drain plate of discrete 10 kV SiC MOSFET for heat dissipation can result in 44.5% increase in switching energy loss at low load current.

Huang, Xingxuan↗

Reduced-Order Structure-Preserving Model for Parallel-Connected Three-Phase Grid-Tied Inverters: Preprint

Given that next-generation infrastructures will contain large numbers of grid-connected inverters and these interfaces will be satisfying a growing fraction of system load, it is imperative to analyze the impacts of power electronics on such systems. However, since each inverter model has a relatively large number of dynamic states, it would be impractical to execute complex system models where the full dynamics of each inverter are retained. To address this challenge, we derive a reduced-order structure-preserving model for parallel-connected grid-tied three-phase inverters. Here, each inverter in the system is assumed to have a full-bridge topology, LCL filter at the point of common coupling, and the control architecture for each inverter includes a current controller, a power controller, and a phase-locked loop for grid synchronization. We outline a structure-preserving reduced-order inverter model for the setting where the parallel inverters are each designed such that the filter components and controller gains scale linearly with the power rating. By structure preserving, we mean that the reduced-order three-phase inverter model is also composed of an LCL filter, a power controller, current controller, and PLL. That is, we show that the system of parallel inverters can be modeled exactly as one aggregated inverter unit and this equivalent model has the same number of dynamical states as an individual inverter in the paralleled system. Numerical simulations validate the reduced-order models.

24 POWER TRANSMISSION AND DISTRIBUTION↗