Search NASA⌕ Search

SEARCH · Search NASA

Results for “Inlets”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Techno-economic Evaluation of Utility-Scale Power Plants Based on the Indirect sCO2 Brayton Cycle - Presentation

This presentation discusses the results of a techno-economic analysis (TEA) of a coal-fired utility scale power plant based on the indirect supercritical carbon dioxide (sCO2) Brayton cycle using an oxy-fired circulating fluidized bed (CFB). A baseline plant configuration was examined as well as three variations to the sCO2 power cycle examining the impact of reheat (Rht), main compressor intercooling (IC), and a combination of reheat and main compressor intercooling (RhtIC). Each plant configuration was assessed at two turbine inlet temperatures of 620 °C and 760 °C.

Brayton power cycle↗

Ceramic Matrix Composite Advanced Transition for 65% Combined Cycle Efficiency Turbines - Final Report

This project under DE-FOA-0001107 targeted the development of a CMC-based design for Siemens’ Advanced Transition in support of 65% efficient gas turbines. The current Advanced Transition (AT) already demonstrates significant mid-frame cooling and leakage savings over conventional designs. The CMC application will further reduce mid-frame cooling air consumption and result in emissions and/or performance improvements beyond the current AT benefits by A. Reducing NO x – by effectively reducing the combustion zone’s temperature for a constant Turbine Inlet Temperature (TIT) or by B. Increasing TIT - enabling an increase in engine efficiency and power output without a corresponding increase in NO x emissions.

02 PETROLEUM↗

Integrated Flue Gas Purification and Latent Heat Recovery for Pressurized Oxy-Combustion (Final Scientific/Technical Report)

Pressurized oxy-combustion has been identified by DOE as a transformational technology for coal power with carbon capture due to the advantages that are realized when the combustion process is pressurized. The staged pressurized oxy-combustion (SPOC) process is particularly attractive as the efficiency of the process is almost 6 percentage points greater than that of first generation oxy-combustion. A critical component of the SPOC process, and potentially other pressurized combustion processes, is the Direct Contact Cooler (DCC) where the latent heat of the flue gas moisture is recovery to improve plant efficiency while simultaneously removing SO x and NO x from the flue gas, so that the FGD and de-NO x processes can be eliminated, and the cost of electricity minimized. The objective of this R&D effort was to advance the TRL of the DCC technology, which included performance testing at a 100 kW scale to validate the process and obtain key engineering data for scale-up. A collateral objective was to study the gas- and liquid-phase kinetics, and the development of a systematic chemical mechanism validated by experimental data. Experiments in a bench-scale stirred reactor provided an updated understanding of the liquid chemistry and the effects of temperature and pH. This information was used to develop a reduced reaction mechanism, which was subsequently incorporated in an ASPENbased process model, to allow for evaluation of the DCC at full scale. A small-pilot DCC column was designed, constructed and tested using simulated flue gas at the pressurized oxy-combustion test facility at Washington University in St. Louis. In the majority of tests, the SO 2 capture approached 100%, making the NO x capture the primary metric of capture efficiency. An NO x capture efficiency of 90% was achieved when the gas residence time was 95 seconds, demonstrating that high capture rates can be attained with reasonable reactor size. At higher temperatures (up to 200°C inlet gas temperature) the total NO x scrubbing efficiency was reduced by approximately 10% (compared to room temp.) and this was attributed to a reduced NO oxidation rate. A significant amount of SO 2 was present in the gas outlet (10%) only when the temperature was high and the N:S ratio was low (N/S < 1), which highlights the necessity of controlling the NOx concentration in the flue gas for complete sulfur scrubbing. After incorporated our optimized chemical mechanism into an ASPEN process model, various full-scale configurations of the DCC were evaluate, and the results indicate that the proposed DCC can accomplish its intended goals at full scale and at a modest size. Thus, the results of this project indicate that the DCC is a promising technology for recovery of the latent heat of the moisture in the flue gas while simultaneously scrubbing the nitrogen and sulfur oxides, thus enabling pressurized oxy-combustion, in general, and the SPOC process, in particular.

01 COAL, LIGNITE, AND PEAT↗

ThermoLift – A Natural Gas Fired Air Conditioner and Heat Pump

ThermoLift is developing TC-Cycle™, a natural-gas driven air conditioner and cold-climate heat pump that can provide space heating, water heating, and air conditioning in a single device. Unlike traditional heat-pump system, the TC-Cycle system uses helium as working fluid in place of high global warming potential HFC refrigerant. The system has broad application as a combined HVAC solution and technology development throughout this program has advanced the Technology Readiness Level (TRL) from TRL-1 to TRL-5 achieved in the Gen 3.0 prototype. In August of 2013, the US Department of Energy (DOE) provided Research and Development funding through the Building Technologies Innovations Program Funding Opportunity Announcement DE-FOA-0000823. The statement of work (SOW) outlined a deliverable of testing at ORNL and a final test report prepared to include various heating cooling temperature ranges and performance analysis. Furthermore, a milestone of this effort was to analyze all test data to establish further efficiency improvements and consider optimum manufacturing methodologies to facilitate the next level improvements. ThermoLift’s Gen 3.0 gas-fired heat pump was shipped and installed into ORNL’s test facility with most of the data reported herein obtained on August 6, 2018. Uninterrupted operation demonstrated cycle Coefficient of Performance (COP) well exceeding DOE targets for cold-climate heat pumps. Furthermore, there was no degradation in capacity as inlet (ambient) temperature decreased.

03 NATURAL GAS↗

Data Driven Temperature Control of Heat Exchangers

The following poster presents a couple of approaches for temperature control at heat exchanger’s exit. One of the approaches is based on using n-step ahead neural network while the other approach utilizes a combination of control + learning module for temperature control. Designing robust controllers for typical heat exchangers is very challenging primarily because of complexities associated with the synthesis of dynamics of industrial heat exchangers. Even if a dynamics model is synthesized, the accuracy of it would be called into question as there can be lot of unmodeled system dynamics and random noise in input parameters. In many situations, the degree of uncertainty in the model of system being controlled limits the utility of optimal control design. Controller can be manually tuned on the field but it is very difficult to determine manual adjustments that result in overall improvement. These practical challenges call for learning based approaches for temperature control that would result in optimal heat exchanger performance. We utilize the existing mathematical model for air-water system synthesized by Underwood and Crawford for testing our algorithms. Underwood and Crawford developed a model of heating coil by fitting a second-order non-linear equations to measurements of air and water temperature and flow rates obtained from the actual coil. The uncertainties in the model include air and water inlet temperatures and air-flow rate. These uncertainties are modeled as random variables that are sampled from a uniform distribution. The control variable is the water flow rate which is controlled for regulating the air-outlet temperature. Neural networks are frequently used in various literatures for learning time-series. We propose a modified version of neural networks known as n-step ahead neural network that take the state variables and output at time t as input to successfully predict output at time t+n. The variable n is a hyper-parameter which can be optimized based on performance constraints. The n-step ahead neural network was then trained on training data generated from experimental model to high training accuracies. This trained model performed appreciably in its objective to regulate outlet temperature of a heat exchanger. The second approach uses a combination of control and learning module for temperature regulation. The control module used is a proportional controller while the learning module used is steady state neural network. The steady state neural network is used to learn the controller output as a function of random variables and temperature set-point. The proportional controller is then used to compensate for transient behavior of linearized system around various operating points. The algorithm works effectively for temperature regulation as neural network captures the non-linear input-output behavior of closed loop system leaving proportional controller to compensate for steady state errors of a linearized plant. The proposed algorithm’s performances were evaluated against the performance of a PI controller. Further, the robustness of the algorithms were also studied in great detail under small perturbations around tuned parameters of the proposed algorithms.

Sundar, Sreenath↗

Flexible Geothermal Power Generation utilizing Geologic Thermal Energy Storage (Final Seedling Project Report)

This report concludes that there is a cost-effective strategy for seasonal storage of heat that will provide firm, but dispatchable, electrical generating capacity in times when other renewable energy is not available to meet demand. Deployment of the technology appears to require no new technology, but instead combines solar, geothermal, and conventional oil and gas drilling technologies in a novel way. The study basis is the use of sedimentary geologic formations as a medium for thermal energy storage (TES), specifically for heat collected in concentrating solar collectors. The study identifies methodologies that could be used to transport this heat into and out of the subsurface in order to produce dispatchable electrical power, and reports on initial optimization results. The GeoTES system (heat input, storage, heat recovery, and heat to electric conversion) described in this analysis has the potential to provide a unique pathway for increasing the grid penetration of renewable energy in large blocks of power and across many states and regions. Further, the system can be used both to meet the nation’s flexible energy needs while also improving grid stability and reliability. The present study evaluated the use of a large number of dedicated wells to store and recover the heat, essentially creating a synthetic geothermal reservoir. The use of sedimentary geology allows the wells to be drilled at low cost. Dedicated hot and cold wells are used, arranged in a five-spot well pattern with each hot or cold well surrounded at an appropriate distance by the opposite type of well. In large numbers this becomes alternating rows of hot and cold wells. Each hot and cold well is operated using a push-pull strategy. This configuration provides the ability to immediately recover stored hot fluid from a GeoTES reservoir, or to store the heat over many months for recovery at low loss when needed. This is a practical approach for managing the system’s fluid inventory and reducing parasitic load. The production and injection power requirements are reduced because the rows of wells operating in “push” mode provide help to the wells operating in “pull” mode, and vice-versa. Initial charging of a GeoTES system increases the heat recovery temperature. Increasing the duration of the charging period decreases the magnitude of the temperature fluctuations that occur following prolonged system operation. Because of direct contact of the heated water with the reservoir formation, the production of both hot water and steam from the TES, and the temperature ranges of the recovered fluid (190 – 230°C or 375 – 445°F), conventional geothermal power cycles were used to convert the stored heat to electricity. A power cycle configuration for the GeoTES system was selected following a screening study of a number of flash, and flash/binary hybrid options. This analysis concluded that, of the configurations evaluated, a dual-stage flash steam cycle provides the lowest capital costs per unit net power generation with an acceptable hot brine inlet fluid flow rate. The evaluation included the power plant cost estimate, the cost and number of wells and the associated parasitic loads. Annual power generation performance was simulated to evaluate capacity factor and LCOE. The LCOE calculated for the inherently high capacity GeoTES system was $\$$0.13/kWhe. This value was calculated for the case where the solar thermal collector was sized in such a way that the solar collectors permitted an annual power plant capacity factor of up to 97%. The power cycle was able to provide power to the grid every night of the year, and flexible base-load power during the winter, if needed. This LCOE value compares favorably with reported values for solar photovoltaic plus battery energy storage (PV+BES) systems in the open literature, i.e. $\$$0.148/kWhe for a PV+BES system with 4 hours of electrochemical battery energy storage capacity. Addition of battery energy storage with more hours of storage would further increase PV+BES system LCOE and increase the separation between GeoTES and PV+BES. A GeoTES system would therefore provide superior economics for high capacity and long duration solar energy storage.

14 SOLAR ENERGY↗

Central Receiver Optimization

Sandia National Laboratories (Sandia) and the Commonwealth Scientific and Industrial Research Organisation (CSIRO) collaborated to optimize central receivers in the temperature range of 600-900°C suitable for advanced power cycles. It was recognized that significant cost reductions can be made in concentrating solar power (CSP) if efficiency was substantially improved. Advanced cycles such as supercritical CO 2 (sCO 2 ) power cycles offer the potential for high efficiency, but the solar collector and receiver geometry must be considered together to ensure the required inlet conditions for the turbine can be met in a cost-effective manner. This project investigated heliostat life cycle costs, heliostat field layout and associated receiver geometry to better understand the optical and thermodynamic relationship between these components in this temperature range of interest, allowing subsequent optimization. This work will assist the mission of Sandia, the Department of Energy (DOE), and CSIRO to develop sustainable, cost-competitive energy technologies for public use. The purpose of this work was to investigate factors affecting performance and costs of heliostats, including in-field heliostat testing. Alternative receiver designs designed to achieve high temperatures (900 °C and above) were also explored in conjunction with the heliostat field.

Ho, Clifford K.↗

Ultra High Temperature Anode Recycle Blower for Solid Oxide Fuel Cell (Phase I Final Report)

Under funding from DOE Award DE-FE0031148, Mohawk Innovative Technology, Inc. (MITI) has successfully developed, integrated and tested a prototype ultrahigh speed oil-free blower for use as an Ultra High Temperature Anode Recycle Blower (UHT-ARCB) in a 100 kWe Solid Oxide Fuel Cell (SOFC). MITI’s recycle blower design is hermetically sealed, and features a completely encapsulated permanent magnet motor, which allows it to handle the steam-rich anode recycle gas mixture. At the SOFC’s nominal operating condition, the MITI ARCB rotates at approximately 55000 rpm, raises the pressure of the incoming 621 °C gas from 104 to 112 kPa, and uses less than 1.2 kWe at a rate of approximately 30 g/s. The UHT-ARCB’s thermal management uses the incoming natural gas supply for the SOFC as cooling medium for bearings, seals and motor magnet, along with a water jacket for motor housing cooling to prevent the high temperature gas from affecting the bearing/motor assembly. MITI’s development of this UHT-ARCB will contribute to a reduction of cost and overall balance of plant (BOP) of SOFC systems. The UHT-ARCB recirculates a fraction of the depleted anode exhaust to the fuel-cell inlet. Direct recycling of anode off-gas takes advantage of the water already present in the stream to assist the methane reforming process and inhibit carbon deposition, without the need for an external water supply.

30 DIRECT ENERGY CONVERSION↗

Off-Normal Scenarios Using Resistively Heated Targets

This report describes the continuation of thermal experiments using the resistively heated target assembly within the helium flow loop at LANSCE that is described in the report, Resistively Heated Target Tests Using Helium Flow Loop, by Alexander Wass et al. In order to replicate off-normal operating scenarios of the helium cooled Mo-100 plant design disks during beam heating, an array of resistive heaters were placed within the helium flow loop, cooled via helium, and modified slightly. The resistively heated test piece is comprised of seven ceramic electric heaters with embedded thermocouples allowing temperature measurements of each heater. A total of three scenarios were performed. One unmodified scenario, and two off-normal scenarios were conducted to simulate a blocked cooling channel due to debris within the flow loop and a broken disk during in-beam heating at the Mo-99 production facility. A removable insert was placed within a cooling channel to block the flow of helium, and a resistive heater was removed to simulate a broken disk that had been evacuated from the target assembly. The inlet and outlet cooling pipe employs rectangular tubing to make a 90° bend at a radius consistent with and practical for the actual plant design.

36 MATERIALS SCIENCE↗

Dead-End Filtration and Crystalline Silicotitanate Cesium Ion Exchange with Hanford Tank Waste AW-102

The Direct Feed Low-Activity Waste (DFLAW) flowsheet provides for the initial production of immobilized low-activity waste (ILAW) by feeding low-activity waste (LAW) directly from tank farms to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) LAW facility for immobilization. Prior to the transfer of feed to the WTP LAW facility, tank supernatant waste will be pretreated by the Tank Side Cesium Removal (TSCR) system to meet the WTP LAW waste acceptance criteria (<3.18E-5 Ci 137Cs/mole of Na). This pretreatment facility will filter the waste to remove suspended solids and remove cesium from the waste stream through ion exchange. Bench-scale filtration testing of 7.4 liters of diluted of AW-102 supernate was conducted using dead-end filtration in the hot cells of the Radiochemical Processing Laboratory at Pacific Northwest National Laboratory. A Mott 70-mm disc filter (media grade 5) was used to capture solids. The filter area was adjusted to 2.2 in2 to match the planned TSCR supernate process volume to surface area ratio. There was no indication of filter fouling and no recoverable solids were observed on the filter. Ion exchange testing with the filtered, diluted AW-102 supernatant was conducted using crystalline silicotitanate (CST) ion exchange media. The IONSIV R9140-B CST was provided by Honeywell UOP, LLC in 2018 (Lot number 8056202-999). The column testing operations were prototypic to the intended Low-Activity Waste Pretreatment System operations in a lead-lag column format, although on a small-scale basis with 10-mL CST beds. The feed was processed downflow through the lead column and then through the lag column at ~1.8 bed volumes per hour (BV/h). After 88.6 BVs of feed processing, the volume in the feed bottle dropped below the inlet tube and the lead column fluid headspace was displaced with air. Feed processing was suspended while a new column was prepared and installed into the lead position. A total of 450 BVs of diluted AW-102 feed were processed through the new lead column; only 4.3% Cs breakthrough was achieved. This volume of feed was insufficient to generate useful Cs loading information without extrapolation. A straight-line extrapolation was used to determine the 50% breakthrough of the lead column and contract limit breakthrough from the lag. The values were found to be 1200 BVs and 930 BVs, respectively.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RCCS Testing with the Water-based NSTF: Year-1 Single-Phase Results

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large scale test facility has been constructed to generate validation data for passive decay heat removal systems of advanced reactors. Located at Argonne National Laboratory, the Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS). This report serves as a summary of the single-phase testing results obtained during the programs first year of matrix testing. An introduction to the high-level program objectives is first presented, followed by a brief summary of facility design, instrumentation, and control systems. Details of the NQA-1 driven test method are included, which govern the programs quality assurance requirements and provide a background for the testing strategy and procedures. Checkout activities, including verification of gross system mass and energy balances, heat loss quantification, and isothermal facility characterization, were performed early in the first year and results presented in this report. These tests have identified relevant facility characteristics such as K-factors, frictional pressure losses, parasitic heat loss rates, and transient heating response. Results are then presented from four accepted matrix tests where the facility established a steady-state, single-phase mode of flow operation. All matrix tests were performed with an identical top-level procedure: first initiating a heater power ramp to target levels, and then holding power levels constant until the facilities structural members and network piping reached thermal equilibrium. Upon obtaining stable thermal and hydraulic conditions, active cooling was initiated off of the bulk storage tank to maintain constant riser inlet temperatures of 30°C. This steady-state period was then held for a minimum required duration, at which point the heaters were ramped down and test concluded. The two baseline tests completed reflect conditions prototypic to the full scale plant at both normal operation, and design basis Depressurized Loss of Forced Cooling (DLOFC) conditions. These parameters are defined by full RCCS decay heat loads of 1.4 MWt and 2.1 MWt, which translate to NSTF scale thermal power levels of 34.4 kWt and 51.6 kWt, respectively. Two additional tests were also conducted, which repeated baseline cases but included modification by single parameter variations in decay heat load, or heater power, at 700 kWt, and 2.8 MWt. Finally, a scoping test was performed to demonstrate the facilities ability to operate in a two-phase mode of operation. The facility successfully operated for a 3-hour period at this mode, reaching peak inventory temperatures of 105°C and condensing approximately 50 gallons of boil-off inventory. The testing parameters for this demonstration were based off the design basis DLOFC condition, and will be the reference for new baseline cases as the program moves forward with two-phase matrix testing.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal Hydraulic Experimental Test Article: Status Report for FY2019

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in an SFR. High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. Figure 1 illustrates the main components of the primary system. THETA will be installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, the secondary system in the 18-inch Test Vessel #6, and its sodium-to-air heat exchanger will occupy the location for 18-inch Test Vessel #5 (Test Vessel #5 will not be installed), Figure 2. The design work for the facility has been completed and is currently in the procurement, manufacturing and initial testing stage. The THETA primary system, including the redan, inlet and outlet plenum, 38 kW electric core simulant heater, submerged flowmeter, pump, and all instrumentation has either been procured or is currently being tested at Argonne. The secondary sodium system for cooling the tube-side sodium of the intermediate heat exchanger has all been analyzed according to ASME code and is in the final development stages before procurement.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Continuation Report: Creep-fatigue Behavior and Damage Accumulation of a Candidate Structural Material for Concentrating Solar Thermal Receiver

At the start of this phase, six alloys were determined to be candidate materials for the concentrating solar power (CSP) thermal receiver: Alloys 617, 625, 740H, 230, 282 and Alloy X. From these, Alloys 740H and 282 were determined to be the most suitable, with both alloys exhibiting similar high temperature strength properties. Alloy 740H was selected due to its ease to work with (simpler heat treatments and welding procedures) and a larger database of existing data. Fatigue testing was started in this phase, with four fatigue tests having been completed, with additional fatigue testing planned, as well as tensile, creep and creep-fatigue tests starting in the next phase. Two fatigue tests performed at 850 °C and were completed in significantly fewer cycles than the two tests performed at 750 °C. Metallography was performed on the fatigued specimens to examine crack path and surrounding microstructure. These preliminary results suggest a significant drop in strength at elevated temperatures above 750 °C, however, more test results will be needed prior to setting design limits. Several potential model high temperature design methods were evaluated that could form the basis of our final recommended creep-fatigue design method for Alloy 740H. To do this we expanded on the receiver finite element model to develop a model representative of a potential Gen 3 design using KCl-MgCl2 salt coolant and operating with a salt inlet temperature of 550°C and salt outlet temperature of 720°C. Using the temperature fields from the model thermohydraulic analysis we determined the design life of the reference receiver assuming it was constructed from 740H seamless tubing and assuming high temperature design properties for 740H from literature data and, where required, naïve extrapolation. As experimental data is generated, these tentative design parameters will be updated to match the actual performance of 740H in elevated temperature service. The results of this design study are a rank ordering of potential design methods for two criteria: ease of use and design margin. The end goal of this project is to develop a creep-fatigue design method with adequate, but not over conservative, design margin that is straightforward to execute. Our receiver model is based on the preliminary design provided to DOE by Solar Reserve. Our analysis indicates a peak metal temperature of around 840° C for this design (comparable to Solar Reserve’s analysis, which shows a peak metal temperature of around 830° C). The Solar Reserve tube thickness is too thin to sustain creep-fatigue loading at this temperature. This means that the current trial design is not well-suited for evaluating different design methodologies, as we predict it will have a very short design life. We suggest that we modify our reference design with input from DOE in order to lower the maximum metal temperature to less than 800° C. We can then repeat these analyses and give a more meaningful comparison of different design methods before making a final selection.

14 SOLAR ENERGY↗

Performance Evaluation of the ThermoLift Natural Gas Fired Air Conditioner and Cold-Climate Heat Pump

ThermoLift is currently developing its Thermal Compression Heat Pump (TCHP™), a natural-gas driven air conditioner and cold-climate heat pump, which can provide space heating, water heating, and air conditioning simultaneously in a single device. The system has broad application as a combined heating, ventilation, and air-conditioning (HVAC) solution with the benefit of substantial energy, cost, and greenhouse gas (GHG) reductions. Unlike traditional vapor compression heat-pumps, the TCHP™ uses helium as a working fluid in place of high global warming potential (GWP) refrigerants. The development effort has produced three iterations or generations of prototypes with advancement of the technology readiness level (TRL) from TRL-1 (TCHP™ Gen 1.0) to TRL-5 (TCHP™ Gen 3.0). In August of 2013, the US DOE solicited the submission of proposals through funding opportunity announcement DE-FOA-0000823, Building Technologies Innovations Program. The Office of Energy Efficiency and Renewable Energy (EERE) subsequently accepted ThermoLift’s proposal to develop a heat pump system based on the Hofbauer cycle, a new cycle that supplants the Vuilleumier cycle and provided funding for prototype evaluation at Oak Ridge National Laboratory (ORNL). ORNL is a widely known research center for developing and evaluating building technologies. Through its Building Technologies Research and Integration Center, ORNL has unique capabilities which allows them to collaborate with industry and academia to advance building component technologies. The TCHP™ Gen 3.0 prototype was shipped to ORNL on July 23, 2018. After installation and integration of the heat pump into ORNL’s test facility and performing instrumentation validation and calibration, extended operation of the heat pump was achieved during continuous operation on August 6, 2018, and includes various heating and cooling temperature ranges and performance analysis. The Gen 3.0 prototype was evaluated at four “ambient” temperatures: −25°C, −8.33°C, 8.33°C, and 20°C, (−13°F, 17°F, 47°F, and 68°F) denoted as test points 1-4, respectively. For heating, cycle coefficients of performance (COP) at the four “ambient” temperatures were found to be 1.30, 1.46, 1.52, and 1.61, respectively. Furthermore, there is no capacity reduction as the inlet temperature to the cold heat exchanger (HX) decreases. The heating capacity delivered by the TCHP was found to be 12 kW at -25°C. Finally, this final report identifies measures for obtaining further efficiency improvements.

42 ENGINEERING↗

Advanced supercritical carbon dioxide cycles

The supercritical carbon dioxide cycle (sCO2) has been chosen as the most promising cycle to meet the SunShot goals with a power block that has the potential to achieve thermal efficiencies of 50+% with a turbine inlet temperature of 720 o C. While this cycle has significant potential, it is a fairly new cycle and therefore the costs and performance of the cycle are not known to the level required for detailed economic analysis. There are also multiple cycle configurations that may be used and the choice of configuration could depend on size, cost constraints, efficiency, cooling mode, O&M costs, etc. Each of the variants has particular advantages and drawbacks that have to be understood. The most cost effective way to understand these variants is to use models that allow us to predict the performance of the cycles linked to the heat source (solar thermal energy). In order to do this these models, need to be developed and improved to better predict the costs and performance of the cycle. One of the issues identified with the supercritical Brayton cycle is the fact that a large amount of internal heat exchange is required in order for it to realize its efficiency potential. To address this, recuperators of the Printed Circuit Heat Exchanger (PCHE) design have been primarily considered. While PCHEs are fairly advanced technology and have significant potential there are several drawbacks associated with them. The first being their cost; it is estimated that the two recuperators in a recompression Brayton cycle will cost more than 30% of the entire power block. Another major issue is the in service performance and lack of ability to repair or easily clean the recuperators. If there is a defect in a diffusion bond, fouling or plugging of the channels or mechanical damage due to rapid thermal transient then the entire PCHE may need to be replaced. The third issue is the lack of data and information on the performance of PCHEs at the scale that would be required even for a small 10 MWe plant. To date PCHE heat exchangers have not been constructed at this size and it is necessary to have multiple modules headered together in order to be able to recuperate up to the 40 MWth required in even a small, 10 MWe plant.

14 SOLAR ENERGY↗

Modeling Continuous-Flow Reactor Improvements over Batch Reactions for Enzyme Catalyzed Microsphere Surface Reactions

Our research objective was to study enzymatic reactions occurring on microsphere surfaces. Specifically, our work involved enzymatic polymerization reactions (chain lengthening) taking place both in batch and in a continuous flow reactor. My research involved creating simulations using COMSOL Multiphysics 5.4a to further study variable interactions within the continuous flow reactor. Our goal was to use suitable software to create a simulation platform suite that could be used for advanced research studies of continuous flow enzymatic surfaces reactions. In addition, we studied various characteristics of our present enzymatic polymerization reactor assembly, modeled inlet species flow (Species M) and estimated outlet species production (Species P). Our simulations spanned three levels of detail: Single-Bead, Packed-Bead Cell and Full Reactor Column. Furthermore, the Packed-Bead Cells were studied using three possible regular arrangement of solid spheres: Face-Centered Cubic (FCC), Hexagonal Close Packed (HCP) and Cubic Close Packed (CCP).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design of Fieldable Head Space Manifold

A system has been designed and built to meet the expected requirements for sampling large UF 6 cylinders in the field and to provide similar purification and analyses to those currently performed for 1S and 2S samples at Oak Ridge National Laboratory (ORNL). The system was designed to be modular, allowing flexibility to perform under a variety of conditions. At a minimum, a large cylinder can be accessed to collect head space samples. These samples can additionally be processed in the field to generate 10 cc purified samples that should be similar to ones currently generated at ORNL from sampling of smaller cylinders. Variable inlet mass spectrometer operation can be performed at the time of purification or at a different location on a purified sample. This design should allow collection, processing and analysis of one extracted sample per day based on similar operations using the ORNL manifold. Reduced operations can be performed at a slightly faster rate although movement between cylinders does require time to evacuate and dry the connection adequately for accessing the UF 6 head space.

42 ENGINEERING↗

Iodine Capture and Mechanical Stability of Modified Silver-Functionalized Silica Aerogel

Silver-functionalized silica aerogel (AgAero) is a material proposed for use in the removal of iodine from the off-gas streams arising from nuclear fuel reprocessing. This material was developed by Pacific Northwest National Laboratory and has been shown to adsorb up to 300 mg of iodine per gram of AgAero. One of the challenges noted for AgAero as an iodine sorbent is its mechanical stability. Its initial particle size is >0.85 mm, but previous testing has shown that extended exposure to heated gas streams results in the degradation of the material such that the sorbent bed is compacted with a substantial amount of fines produced. The observed mechanical degradation prompted an effort to reengineer the silica aerogel to improve the mechanical stability of the material without compromising its iodine capture characteristics. Pacific Northwest National Laboratory has modified the material with the intention of strengthening the aerogel backbone and improving mechanical durability. This reengineered material was transferred to Oak Ridge National Laboratory for extended testing to assess its mechanical durability. Modified AgAero was continuously exposed to a CH 3 I-bearing humid gas stream for 84 days. Testing was performed at 150°C with a superficial gas velocity of 10 m/min., a CH 3 I concentration of 554 ppb, and an inlet dew point of 10°C. The density of the AgAero increased by 16% during testing, and the height of the column was observed to decrease by 11%. The fines produced by the material were comparable to that of previously supplied material. Additionally, iodine loading of a thin bed of modified AgAero was performed at 150°C with a superficial gas velocity of 10 m/min. and a CH 3 I concentration of 50 ppm (balance dry air) with a total test duration of 1 week. The CH 3 I capture capacity of the reengineered material was 225 mg iodine per gram AgAero, as compared to a CH 3 I capacity of 250 mg iodine per gram AgAero for the original material. The primary data collected were visual observations, density measurements before and after testing, and the extent of column compaction during testing. Additionally, the material was tested to ensure that the iodine capacity of the material was not adversely impacted by the alternative methods used in the production of the reengineered material. Based on these criteria, no distinguishable improvements were observed between the material produced in fiscal years 2017 and 2019 and the mechanical stability of the aerogel in prototypic off-gas conditions remains a challenge to large-scale deployment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗