Search NASA⌕ Search

SEARCH · Search NASA

Results for “Method development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

SU-E-T-111: An Iterative Approach to Modelling Dosimetric Properties of a Varian MLC

Purpose: In effort to efficiently and accurately model MLC parameters for use in Varian Eclipse treatment planning system (TPS), an iterative technique for characterizing the dosimetric properties of MLCs has been developed. Methods: The initial characterization of the dosimetric leaf gap (DLG) and MLC transmission was performed using varied sizes of moving gaps and transmission measurements through central axis of the radiation beam. These values were determined during the initial data collection. After the initial values were determined and entered into the TPS, two plans were calculated to test the veracity of DLG and transmission independently. The plan used to determine the DLG has openings of varied sizes which are affected differently by the DLG. A large field uniform fluence that required a MLC carriage shift was used to determine the transmission value independent of DLG. After characterizing the dosimetric properties of the MLC independently, clinical IMRT plans were tested and used to tweak the final values. Results: This approach to modelling MLC dosimetric properties was employed for: standard 120 leaf MLC (SDMLC) and 120 leaf high definition MLC (HDMLC). Both types were successfully commissioned, tested, and approved for clinical use on 4 SDMLC machines and 2 HDMLC machines. The pass rate of clinical IMRT plans was 96.9% for 6MV and 98.3% for 10MV for SDMLC and 96.3% for 6MV, 96.5% for 6FFF, and 97.5% for 10FFF for HDMLCs using MapCheck2 with gamma analysis of 2%/2mm and 10% threshold. The final DLG and transmission parameters for 6X were 0.5mm and 0.01, and 1.35mm and 0.02 for HD and SD MLCs respectively. Conclusion: This iterative approach of determining dosimetric properties of MLCs is viable for both SDMLC and HDMLC and multiple energies. This approach accurately and efficiently determines the values needed for commissioning MLCs when they are employed for modulated therapies.

60 APPLIED LIFE SCIENCES↗

SU-E-T-597: Parameterization of the Photon Beam Dosimetry for a Commercial Linear Accelerator

Purpose: In radiation therapy, accurate data acquisition of photon beam dosimetric quantities is important for (1) beam modeling data input into a treatment planning system (TPS), (2) comparing measured and TPS modelled data, (3) a linear accelerator’s (linac) beam characteristics quality assurance process, and (4) establishing a standard data set for data comparison, etcetera. Parameterization of the photon beam dosimetry creates a portable data set that is easy to implement for different applications such as those previously mentioned. The aim of this study is to develop methods to parameterize photon percentage depth doses(PDD), profiles, and total scatter output factors(Scp). Methods: Scp, PDDs and profiles for different field sizes (from 2×2 to 40×40cm{sup 2}), depths and energies were measured in a linac using a three-dimensional water tank. All data were smoothed and profile data were also centered, symmetrized and geometrically scaled. The Scp and PDD data were analyzed using exponential functions. For modelling of open and wedge field profiles, each side was divided into three regions described by exponential, sigmoid and Gaussian equations. The model’s equations were chosen based on the physical principles described by these dosimetric quantities. The equations’ parameters were determined using a least square optimization method with the minimal amount of measured data necessary. The model’s accuracy was then evaluated via the calculation of absolute differences and distance–to–agreement analysis in low gradient and high gradient regions, respectively. Results: All differences in the PDDs’ buildup and the profiles’ penumbra regions were less than 2 mm and 0.5 mm, respectively. Differences in the low gradient regions were 0.20 ± 0.20% and 0.50 ± 0.35% for PDDs and profiles, respectively. For Scp data, all differences were less than 0.5%. Conclusion: This novel analytical model with minimum measurement requirements proved to accurately calculate PDDs, profiles, and Scp for different field sizes, depths and energies.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-610: Phosphor-Based Fiber Optic Probes for Proton Beam Characterization

Purpose: To investigate feasibility of using fiber optics probes with rare-earth-based phosphor tips for proton beam radiation dosimetry. We designed and fabricated a fiber probe with submillimeter resolution (<0.5 mm3) based on TbF3 phosphors and evaluated its performance for measurement of proton beam including profiles and range. Methods: The fiber optic probe with TbF3 phosphor tip, embedded in tissue-mimicking phantoms was irradiated with double scattering proton beam with energy of 180 MeV. Luminescence spectroscopy was performed by a CCD-coupled spectrograph to analyze the emission spectra of the fiber tip. In order to measure the spatial beam profile and percentage depth dose, we used singular value decomposition method to spectrally separate the phosphors ionoluminescence signal from the background Cerenkov radiation signal. Results: The spectra of the TbF3 fiber probe showed characteristic ionoluminescence emission peaks at 489, 542, 586, and 620 nm. By using singular value decomposition we found the contribution of the ionoluminescence signal to measure the percentage depth dose in phantoms and compared that with measurements performed with ion chamber. We observed quenching effect at the spread out Bragg peak region, manifested as under-responding of the signal, due to the high LET of the beam. However, the beam profiles were not dramatically affected by the quenching effect. Conclusion: We have evaluated the performance of a fiber optic probe with submillimeter resolution for proton beam dosimetry. We demonstrated feasibility of spectral separation of the Cerenkov radiation from the collected signal. Such fiber probes can be used for measurements of proton beams profile and range. The experimental apparatus and spectroscopy method developed in this work provide a robust platform for characterization of proton-irradiated nanophosphor particles for ultralow fluence photodynamic therapy or molecular imaging applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Parameterization of photon beam dosimetry for a linear accelerator

Purpose: In radiation therapy, accurate data acquisition of photon beam dosimetric quantities is important for (1) beam modeling data input into a treatment planning system (TPS), (2) comparing measured and TPS modeled data, (3) the quality assurance process of a linear accelerator’s (Linac) beam characteristics, (4) the establishment of a standard data set for comparison with other data, etcetera. Parameterization of the photon beam dosimetry creates a data set that is portable and easy to implement for different applications such as those previously mentioned. The aim of this study is to develop methods to parameterize photon beam dosimetric quantities, including percentage depth doses (PDDs), profiles, and total scatter output factors (S{sub cp}). Methods: S{sub cp}, PDDs, and profiles for different field sizes, depths, and energies were measured for a Linac using a cylindrical 3D water scanning system. All data were smoothed for the analysis and profile data were also centered, symmetrized, and geometrically scaled. The S{sub cp} data were analyzed using an exponential function. The inverse square factor was removed from the PDD data before modeling and the data were subsequently analyzed using exponential functions. For profile modeling, one halfside of the profile was divided into three regions described by exponential, sigmoid, and Gaussian equations. All of the analytical functions are field size, energy, depth, and, in the case of profiles, scan direction specific. The model’s parameters were determined using the minimal amount of measured data necessary. The model’s accuracy was evaluated via the calculation of absolute differences between the measured (processed) and calculated data in low gradient regions and distance-to-agreement analysis in high gradient regions. Finally, the results of dosimetric quantities obtained by the fitted models for a different machine were also assessed. Results: All of the differences in the PDDs’ buildup and the profiles’ penumbra regions were less than 2 and 0.5 mm, respectively. The differences in the low gradient regions were 0.20% ± 0.20% (<1% for all) and 0.50% ± 0.35% (<1% for all) for PDDs and profiles, respectively. For S{sub cp} data, all of the absolute differences were less than 0.5%. Conclusions: This novel analytical model with minimum measurement requirements was proved to accurately calculate PDDs, profiles, and S{sub cp} for different field sizes, depths, and energies.

61 RADIATION PROTECTION AND DOSIMETRY↗

How does C-VIEW image quality compare with conventional 2D FFDM?

Purpose: The FDA approved the use of digital breast tomosynthesis (DBT) in 2011 as an adjunct to 2D full field digital mammography (FFDM) with the constraint that all DBT acquisitions must be paired with a 2D image to assure adequate interpretative information is provided. Recently manufacturers have developed methods to provide a synthesized 2D image generated from the DBT data with the hope of sparing patients the radiation exposure from the FFDM acquisition. While this much needed alternative effectively reduces the total radiation burden, differences in image quality must also be considered. The goal of this study was to compare the intrinsic image quality of synthesized 2D C-VIEW and 2D FFDM images in terms of resolution, contrast, and noise. Methods: Two phantoms were utilized in this study: the American College of Radiology mammography accreditation phantom (ACR phantom) and a novel 3D printed anthropomorphic breast phantom. Both phantoms were imaged using a Hologic Selenia Dimensions 3D system. Analysis of the ACR phantom includes both visual inspection and objective automated analysis using in-house software. Analysis of the 3D anthropomorphic phantom includes visual assessment of resolution and Fourier analysis of the noise. Results: Using ACR-defined scoring criteria for the ACR phantom, the FFDM images scored statistically higher than C-VIEW according to both the average observer and automated scores. In addition, between 50% and 70% of C-VIEW images failed to meet the nominal minimum ACR accreditation requirements—primarily due to fiber breaks. Software analysis demonstrated that C-VIEW provided enhanced visualization of medium and large microcalcification objects; however, the benefits diminished for smaller high contrast objects and all low contrast objects. Visual analysis of the anthropomorphic phantom showed a measureable loss of resolution in the C-VIEW image (11 lp/mm FFDM, 5 lp/mm C-VIEW) and loss in detection of small microcalcification objects. Spectral analysis of the anthropomorphic phantom showed higher total noise magnitude in the FFDM image compared with C-VIEW. Whereas the FFDM image contained approximately white noise texture, the C-VIEW image exhibited marked noise reduction at midfrequency and high frequency with far less noise suppression at low frequencies resulting in a mottled noise appearance. Conclusions: Their analysis demonstrates many instances where the C-VIEW image quality differs from FFDM. Compared to FFDM, C-VIEW offers a better depiction of objects of certain size and contrast, but provides poorer overall resolution and noise properties. Based on these findings, the utilization of C-VIEW images in the clinical setting requires careful consideration, especially if considering the discontinuation of FFDM imaging. Not explicitly explored in this study is how the combination of DBT + C-VIEW performs relative to DBT + FFDM or FFDM alone.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP2-13: Spatial Accuracy Evaluation for Real-Time MR Guided Radiation Therapy Using a Novel Large-Field MRI Distortion Phantom

Purpose: Evaluate a large-field MRI phantom for assessment of geometric distortion in whole-body MRI for real-time MR guided radiation therapy. Methods: A prototype CIRS large-field MRI distortion phantom consisting of a PMMA cylinder (33 cm diameter, 30 cm length) containing a 3D-printed orthogonal grid (3 mm diameter rods, 20 mm apart), was filled with 6 mM NiCl{sub 2} and 30 mM NaCl solution. The phantom was scanned at 1.5T and 3.0T on a GE HDxt and Discovery MR750, respectively, and at 0.35T on a ViewRay system. Scans were obtained with and without 3D distortion correction to demonstrate the impact of such corrections. CT images were used as a reference standard for analysis of geometric distortion, as determined by a fully automated gradient-search method developed in Matlab. Results: 1,116 grid points distributed throughout a cylindrical volume 28 cm in diameter and 16 cm in length were identified and analyzed. With 3D distortion correction, average/maximum displacements for the 1.5, 3.0, and 0.35T systems were 0.84/2.91, 1.00/2.97, and 0.95/2.37 mm, respectively. The percentage of points with less than (1.0, 1.5, 2.0 mm) total displacement were (73%, 92%, 97%), (54%, 85%, 97%), and (55%, 90%, 99%), respectively. A reduced scan volume of 20 × 20 × 10 cm{sup 3} (representative of a head and neck scan volume) consisting of 420 points was also analyzed. In this volume, the percentage of points with less than (1.0, 1.5, 2.0 mm) total displacement were (90%, 99%, 100%), (63%, 95%, 100%), and (75%, 96%, 100%), respectively. Without 3D distortion correction, average/maximum displacements were 1.35/3.67, 1.67/4.46, and 1.51/3.89 mm, respectively. Conclusion: The prototype large-field MRI distortion phantom and developed software provide a thorough assessment of 3D spatial distortions in MRI. The distortions measured were acceptable for RT applications, both for the high field strengths and the system configuration developed by ViewRay.

60 APPLIED LIFE SCIENCES↗

Energy filtering–induced ultrahigh thermoelectric power factors in Ni 3 Ge

Traditional thermoelectric materials rely on low thermal conductivity to enhance their efficiency but suffer from inherently limited power factors. Innovative pathways to optimize electronic transport are thus crucial. Here, we achieve ultrahigh power factors in Ni 3 Ge-based systems through an unconventional thermoelectric materials design principle. When overlapping flat and dispersive bands are engineered to the Fermi level, charge carriers can undergo intense interband scattering, yielding an energy filtering effect similar to what has long been predicted in certain nanostructured materials. Via a multistep DFT-based screening method developed here, we find a family of L1 2 -ordered binary compounds with ultrahigh power factors up to 11 mW m −1 K −2 near room temperature, which are driven by an intrinsic phonon-mediated energy filtering mechanism. Our comprehensive experimental and theoretical study of these intriguing materials paves the way for understanding and designing high-performance scattering-tuned metallic thermoelectrics.

Science & Technology - Other Topics↗

Printed Assemblies of Inorganic Light-Emitting Diodes for Deformable and Semitransparent Displays

We have developed methods for creating microscale inorganic light-emitting diodes (LEDs) and for assembling and interconnecting them into unusual display and lighting systems. The LEDs use specialized epitaxial semiconductor layers that allow delineation and release of large collections of ultrathin devices. Diverse shapes are possible, with dimensions from micrometers to millimeters, in either flat or “wavy” configurations. Printing-based assembly methods can deposit these devices on substrates of glass, plastic, or rubber, in arbitrary spatial layouts and over areas that can be much larger than those of the growth wafer. Furthermore, the thin geometries of these LEDs enable them to be interconnected by conventional planar processing techniques. Displays, lighting elements, and related systems formed in this manner can offer interesting mechanical and optical properties.

42 ENGINEERING↗

Surface Plasmon Resonance and Aggregate Stability of Silver Nanoparticle Complexes with Chemotripsin

Extinction spectra, effective sizes, and aggregate stability of silver nanoparticles and nanocomplexes of silver nanoparticles with chymotrypsin obtained by the reactions of chemical reduction of silver nitrate using sodium borohydride as a reducing agent are studied. It is shown that silver nanoparticles obtained in the absence of chymotrypsin are aggregatively stable only at pH values immediately after synthesis. The placement of the synthesized silver nanoparticles in buffer solutions with pH values from 3.0 to 12.0 resulted in the appearance of a wide absorption band in the visible region of the spectrum, which is due to the agglomeration of silver nanoparticles, which appears to be the result of the destruction of the double electric layer formed by the ions making up sodium borohydride. The presence of chymotrypsin in the reaction medium resulted in significant spectral changes. Unlike silver nanoparticles synthesized in the absence of chymotrypsin, for nanocomplexes of silver nanoparticles with chymotrypsin with a change in pH, the shape of the extinction spectra and the position of the surface plasmon resonance band were preserved, while nanocomplexes of silver nanoparticles with chymotrypsin retained the aggregative stability in solutions in the pH range from 3.0 to 12.0 within a month. The observed stabilization effect of silver nanoparticles over a wide pH range induced by the presence of chymotrypsin in the reaction medium can be used further to develop methods for immobilizing enzymes on nanoparticles of biogenic elements and for creating polyfunctional pharmaceuticals, in which the components of nanocomplexes have different biological activity.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

X-ray diffraction study of BaTiO{sub 3} single crystals before and after fast-neutron irradiation

The neutron irradiation of ferroelectrics is efficiently used to form structural states that cannot be obtained by conventional technologies. To date, the effect of neutron irradiation on the structure and properties of BaTiO{sub 3} has been studied for only ceramic materials. We have considered the influence of fast-neutron irradiation (F = 1 × 10{sup 17} cm{sup −2}) on the structure and properties of BaTiO{sub 3} single crystals for the first time. The structural changes occurring in irradiated BaTiO{sub 3} and their correlation with the behavior of dielectric and nonlinear optical characteristics are analyzed with the aid of a specially developed method for taking into account the experimental correction to diffuse scattering. Neutron irradiation to the aforementioned dose retains the polar structure of the material and only slightly changes atomic displacements. The radiationinduced structural changes occur according to the high-temperature type to form a structure similar to the cubic modification of unirradiated BaTiO{sub 3} crystal.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Construction of a dynamical matrix for an HCP crystal using phonon data at the symmetry points of the Brillouin zone and elastic constants

General analytical expressions are obtained for the dynamical matrix D(k) and the elastic constants C{sub ik} in an HCP crystal in terms of the Born-von Karman (BvK) parameters. An analytical method is proposed for constructing D(k) on the basis of data about the phonon frequencies {omega}{sub i}(N) at the symmetry points of the Brillouin zone and the elastic constants C{sub ik}. A number of relations between the values of {omega}{sub i}(N) and C{sub ik} are presented for conventional interaction models. It is shown that the standard method for determining BvK parameters by fitting them to experimental phonon spectra in HCP lattices is, as a rule, ambiguous, whereas the analytical method proposed allows one to find all the solutions of the problem. The methods developed are illustrated by the construction of dynamical matrices for Tb, Sc, Ti, and 0008.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simulation of thermal ionization in a dense helium plasma by the Feynman path integral method

The region of equilibrium states is studied where the quantum nature of the electron component and a strong nonideality of a plasma play a key role. The problem of negative signs in the calculation of equilibrium averages a system of indistinguishable quantum particles with a spin is solved in the macroscopic limit. It is demonstrated that the calculation can be conducted up to a numerical result. The complete set of symmetrized basis wave functions is constructed based on the Young symmetry operators. The combinatorial weight coefficients of the states corresponding to different graphs of connected Feynman paths in multiparticle systems are calculated by the method of random walk over permutation classes. The kinetic energy is calculated using a viral estimator at a finite pressure in a statistical ensemble with flexible boundaries. Based on the methods developed in the paper, the computer simulation is performed for a dense helium plasma in the temperature range from 30000 to 40000 K. The equation of state, internal energy, ionization degree, and structural characteristic of the plasma are calculated in terms of spatial correlation functions. The parameters of a pseudopotential plasma model are estimated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Generalized Ginzburg-Landau functional calculations of the structure and energy of the coherent interphase boundaries between austenite and martensite in iron

The earlier-developed methods and experimental data on the phonon spectra and thermodynamics of fcc and bcc iron are used to construct a generalized Ginzburg-Landau functional for microscopic investigations of the austenite-martensite phase transformations in iron. This functional is used to calculate the structure and properties of a plane austenite-martensite interface for arbitrary orientations of this interface at various temperatures. The transformation parameter profiles in the interface region are calculated. The interface width is found to substantially exceed the interatomic distances. The interfacial surface energy is 500-800 erg/cm{sup 2}, depends strongly on the orientation, and has a sharp maximum when the interface is parallel to a close-packed plane.

36 MATERIALS SCIENCE↗

Subtractive procedure for calculating the anomalous electron magnetic moment in QED and its application for numerical calculation at the three-loop level

A new subtractive procedure for canceling ultraviolet and infrared divergences in the Feynman integrals described here is developed for calculating QED corrections to the electron anomalous magnetic moment. The procedure formulated in the form of a forest expression with linear operators applied to Feynman amplitudes of UV-diverging subgraphs makes it possible to represent the contribution of each Feynman graph containing only electron and photon propagators in the form of a converging integral with respect to Feynman parameters. The application of the developed method for numerical calculation of two- and threeloop contributions is described.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electron in the field of flexural vibrations of a membrane: Quantum time, magnetic oscillations, and coherence breaking

We have studied the motion of an electron in a membrane under the influence of flexural vibrations with a correlator that decreases upon an increase in the distance in accordance with the law r–{sup 2η}. We have conducted a detailed consideration of the case with η < 1/2, in which the perturbation theory is inapplicable, even for an arbitrarily weak interaction. It is shown that, in this case, reciprocal quantum time 1/τ{sub q} is proportional to g{sup 1/(1–η)}T{sup (2–η)/(2–2η)}, where g is the electron–phonon interaction constant and T is the temperature. The method developed here is applied for calculating the electron density of states in a magnetic field perpendicular to the membrane. In particular, it is shown that the Landau levels in the regime with ω{sub c}τ{sub q} » 1 have a Gaussian shape with a width that depends on the magnetic field as B{sup η}. In addition, we calculate the time τ{sub φ} of dephasing of the electron wave function that emerges due to the interaction with flexural phonons for η < 1/2. It has been shown that, in several temperature intervals, quantity 1/τ{sub φ} can be expressed by various power functions of the electron–phonon interaction constant, temperature, and electron energy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coherent scattering of an atom in the field of a standing wave under conditions of initial quantum correlation of subsystems

Coherent scattering of a two-level atom in the field of a quantized standing wave of a micromaser is considered under conditions of initial quantum correlation between the atom and the field. Such a correlation can be produced by a broadband parametric source. The interaction leading to scattering of the atom from the nonuniform field occurs in the dispersion limit or in the wing of the absorption line of the atom. Apart from the quantized field, the atom simultaneously interacts with two classical counterpropagating waves with different frequencies, which are acting in the plane perpendicular to the atom’s propagation velocity and to the wavevector of the standing wave. Joint action of the quantized field and two classical waves induces effective two-photon and Raman resonance interaction on the working transition. The effective Hamiltonian of the interaction is derived using the unitary transformation method developed for a moving atom. A strong effect is detected, which makes it possible to distinguish the correlated initial state of the atom and the field in the scattering of atom from the state of independent systems. For all three waves, scattering is not observed when systems with quantum correlation are prepared using a high-intensity parametric source. Conversely, when the atom interacts only with the nonuniform field of the standing wave, scattering is not observed in the case of the initial factorized state.

74 ATOMIC AND MOLECULAR PHYSICS↗

Thermionic field emission of electrons from the paraboloidal metal micropoint

The problem of determining the emission current as a function of voltage, radius of the micropoint curvature, and the distance between the micropoint and a conducting plane is considered on the basis of the theoretical method developed for determining the electric field in the vicinity of a paraboloidal micropoint near a plane metal surface. The universal current–voltage characteristics for a copper micropoint, which are considered for various distances between the micropoint and the plane, can be used for obtaining quantitative estimates of currents in various physics problems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quasiparticle-phonon interaction in the theory of finite Fermi systems

Within the Green's function method and on the basis of the method developed by V.A. Khodel for analyzing anharmonic effects, effects of quasiparticle-phonon interaction in the second order in the amplitude of phonon production are studied in two problems as a natural development of A.B. Migdal's theory of finite Fermi systems. Transitions between excited states and static moments of magic and nonmagic nuclei in excited states, each of which is described in the random-phase approximation, are considered. The results for this problem are found to differ considerably from those in the quasiparticle random-phase approximation. The inclusion of all second-order anharmonic effects in the extended theory of finite Fermi systems that extends the standard theory of finite Fermi systems to the case of taking into account quasiparticle-phonon interaction in order to describe excited states, but which does not take into account all such effects, is also considered. They are taken into account at a level that makes it possible to calculate static moments of odd nuclei-more precisely, the respective equation for the vertex function, which, in the theory of finite Fermi systems, is a basic ingredient that describes the interaction of a nucleus with an external field, is derived. Some numerical results obtained within the recently implemented self-consistent version of the extended theory of finite Fermi systems are also presented for 15 stable and unstable tin isotopes. These results give sufficient grounds to conclude that phenomenological systematics are inapplicable to giant dipole resonances in neutron-rich isotopes. The cross sections for radiative neutron capture that are calculated by usingmicroscopic strength functions for the neutron-rich isotopes 132Sn and 150Sn differ strongly from the cross sections calculated on the basis of a phenomenological description of giant dipole resonances. These results are of paramount importance for astrophysics and for the theory of nuclear data for reactors since they highlight the inapplicability of phenomenological systematics to giant dipole resonances and the need for self-consistent calculations for neutron-rich nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗