Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mobile Measuring System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Wearable Biosensor Monitor to Support Autonomous Crew Health and Readiness to Perform

For future human exploration missions, NASA needs a health monitoring system composed of hardware that is compact, fully interoperable with an integrated data management system, and requires minimal consumables. Such a system will be achieved through the integration of small, easy to use biomedical sensors that will have the ability to measure, store and transmit physiological parameters during operational and ambulatory activity. Since 2012, the Canadian Space Agency (CSA) has been active in funding the development of wearable biomonitoring sensors. The Astroskin is the first prototype and consists of a shirt-based garment and headband with embedded sensors, and associated software and technology that measure vital signs, sleep quality and activity level of the wearer. NASA and CSA have been collaborating since 2014 to test and validate this system in a lab environment at Ames Research Center and more recently in the Human Exploration Research Analog (HERA) located at Johnson Spaceflight Center. Specific objectives of the HERA study were: 1) to assess the performance of the Astroskin biosensor system for long-term health monitoring (24-hours) capabilities and during exercise as a measure of crew fitness; 2) to obtain crew feedback on comfort and usability of the Astroskin system; 3) to demonstrate performance of Bluetooth communication during real-time transmission and for verification of data in this environment; and 4) to obtain baseline data for further development of algorithms and tools that facilitate decision support for diagnosing and monitoring of a sick or injured crewmember. HERA Campaign 3 included four missions (each 30-days in duration) with four crewmembers assigned to each mission. A total of 9 men and 7 women participated in the Astroskin evaluation that included continuous physiological monitoring (24-hours) on mission days MD-11, MD1 (high workload), MD15 (low workload), MD19, MD29, and MD+7. Mission days 19 and 29 also included 30 minutes of sub-maximal exercise on a cycle ergometer. Following each 24-hour monitoring session crew physiological data were downloaded to laptops and each crewmember completed a 28 question survey on their experiences with the Astroskin hardware and software. This presentation will focus on lessons learned from the HERA missions. Specifically it will address Astroskin system performance in terms of data loss and data quality (no comparison to lab standard devices), wireless communication with the onboard mobile device, crew usability and comfort, and future development of a next generation biomonitoring system.

crew fitness↗

Atomic and electronic structure of exfoliated black phosphorus

Black phosphorus, a layered two-dimensional crystal with tunable electronic properties and high hole mobility, is quickly emerging as a promising candidate for future electronic and photonic devices. Although theoretical studies using ab initio calculations have tried to predict its atomic and electronic structure, uncertainty in its fundamental properties due to a lack of clear experimental evidence continues to stymie our full understanding and application of this novel material. In this work, aberration-corrected scanning transmission electron microscopy and ab initio calculations are used to study the crystal structure of few-layer black phosphorus. Directly interpretable annular dark-field images provide a three-dimensional atomic-resolution view of this layered material in which its stacking order and all three lattice parameters can be unambiguously identified. In addition, electron energy-loss spectroscopy (EELS) is used to measure the conduction band density of states of black phosphorus, which agrees well with the results of density functional theory calculations performed for the experimentally determined crystal. Furthermore, experimental EELS measurements of interband transitions and surface plasmon excitations are also consistent with simulated results. Finally, the effects of oxidation on both the atomic and electronic structure of black phosphorus are analyzed to explain observed device degradation. The transformation of black phosphorus into amorphous PO{sub 3} or H{sub 3}PO{sub 3} during oxidation may ultimately be responsible for the degradation of devices exposed to atmosphere over time.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Li 2 GeS 3 : Lithium Ionic Conductor with an Unprecedented Structural Type

Lithium-ion batteries (LIBs) are widely used in electric vehicles, mobile electronic devices, and large-scale stationary energy storage systems. However, their liquid electrolytes present significant safety concerns due to their inherent flammability. To address this, the focus has shifted toward all-solid-state batteries (ASSBs) utilizing inorganic solid electrolytes that promise enhanced safety. In this work, we report the discovery of a new crystal structural type of Li-ion conductor, Li 2 GeS 3 , with a unique structure, synthesized by a solid-state reaction from Li 2 S and GeS 2 . It was first reported in 2000 with an orthorhombic unit cell, but its detailed crystal structure remains veiled. Here, we have unveiled its structure for the first time, employing an ab initio structure determination technique from powder X-ray and time-of-flight neutron diffraction data. The compound has an unprecedented crystal structural type with a hexagonal $P6_1$ symmetry and a unit cell of α = 6.79364(4) Å and c = 17.90724(14) Å. Its structure is comprised of a distorted hexagonal close-packed arrangement of sulfur anions with three asymmetric metal atoms: Li1, Li2, and Ge are in tetrahedral cavities surrounded by sulfur atoms. The ionic conductivity of Li 2 GeS 3 was measured to be 1.63 × 10 –8 S cm –1 at 303 K and 2.45 × 10 –7 S cm –1 at 383 K. Bond valence energy landscape calculations revealed three-dimensional lithium diffusion pathways within the structure. This novel crystal structure in Li 2 GeS 3 holds the potential for developing high-performance ionic conductors through suitable chemical substitution and offers valuable insights into designing new ionic conductors for ASSBs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

WE-E-12A-01: Medical Physics 1.0 to 2.0: MRI, Displays, Informatics

Medical Physics 2.0 is a bold vision for an existential transition of clinical imaging physics in face of the new realities of value-based and evidence-based medicine, comparative effectiveness, and meaningful use. It speaks to how clinical imaging physics can expand beyond traditional insular models of inspection and acceptance testing, oriented toward compliance, towards team-based models of operational engagement, prospective definition and assurance of effective use, and retrospective evaluation of clinical performance. Organized into four sessions of the AAPM, this particular session focuses on three specific modalities as outlined below. MRI 2.0: This presentation will look into the future of clinical MR imaging and what the clinical medical physicist will need to be doing as the technology of MR imaging evolves. Many of the measurement techniques used today will need to be expanded to address the advent of higher field imaging systems and dedicated imagers for specialty applications. Included will be the need to address quality assurance and testing metrics for multi-channel MR imagers and hybrid devices such as MR/PET systems. New pulse sequences and acquisition methods, increasing use of MR spectroscopy, and real-time guidance procedures will place the burden on the medical physicist to define and use new tools to properly evaluate these systems, but the clinical applications must be understood so that these tools are use correctly. Finally, new rules, clinical requirements, and regulations will mean that the medical physicist must actively work to keep her/his sites compliant and must work closely with physicians to ensure best performance of these systems. Informatics Display 1.0 to 2.0: Medical displays are an integral part of medical imaging operation. The DICOM and AAPM (TG18) efforts have led to clear definitions of performance requirements of monochrome medical displays that can be followed by medical physicists to ensure proper performance. However, effective implementation of that oversight has been challenging due to the number and extend of medical displays in use at a facility. The advent of color display and mobile displays has added additional challenges to the task of the medical physicist. This informatics display lecture first addresses the current display guidelines (the 1.0 paradigm) and further outlines the initiatives and prospects for color and mobile displays (the 2.0 paradigm). Informatics Management 1.0 to 2.0: Imaging informatics is part of every radiology practice today. Imaging informatics covers everything from the ordering of a study, through the data acquisition and processing, display and archiving, reporting of findings and the billing for the services performed. The standardization of the processes used to manage the information and methodologies to integrate these standards is being developed and advanced continuously. These developments are done in an open forum and imaging organizations and professionals all have a part in the process. In the Informatics Management presentation, the flow of information and the integration of the standards used in the processes will be reviewed. The role of radiologists and physicists in the process will be discussed. Current methods (the 1.0 paradigm) and evolving methods (the 2.0 paradigm) for validation of informatics systems function will also be discussed. Learning Objectives: Identify requirements for improving quality assurance and compliance tools for advanced and hybrid MRI systems. Identify the need for new quality assurance metrics and testing procedures for advanced systems. Identify new hardware systems and new procedures needed to evaluate MRI systems. Understand the components of current medical physics expectation for medical displays. Understand the role and prospect fo medical physics for color and mobile display devices. Understand different areas of imaging informatics and the methodology for developing informatics standards. Understand the current status of informatics standards and the role of physicists and radiologists in the process, and the current technology for validating the function of these systems.

07 ISOTOPE AND RADIATION SOURCES↗

Compact, Miniature MMIC Receiver Modules for an MMIC Array Spectrograph

A single-pixel prototype of a W-band detector module with a digital back-end was developed to serve as a building block for large focal-plane arrays of monolithic millimeter-wave integrated circuit (MMIC) detectors. The module uses low-noise amplifiers, diode-based mixers, and a WR10 waveguide input with a coaxial local oscillator. State-of-the-art InP HEMT (high electron mobility transistor) MMIC amplifiers at the front end provide approximately 40 dB of gain. The measured noise temperature of the module, at an ambient temperature of 300 K, was found to be as low as 450 K at 95 GHz. The modules will be used to develop multiple instruments for astrophysics radio telescopes, both on the ground and in space. The prototype is being used by Stanford University to characterize noise performance at cryogenic temperatures. The goal is to achieve a 30-50 K noise temperature around 90 GHz when cooled to a 20 K ambient temperature. Further developments include characterization of the IF in-phase (I) and quadrature (Q) signals as a function of frequency to check amplitude and phase; replacing the InP low-noise amplifiers with state-of-the-art 35-nm-gate-length NGC low-noise amplifiers; interfacing the front-end module with a digital back-end spectrometer; and developing a scheme for local oscillator and IF distribution in a future array. While this MMIC is being developed for use in radio astronomy, it has the potential for use in other industries. Applications include automotive radar (both transmitters and receivers), communication links, radar systems for collision avoidance, production monitors, ground-penetrating sensors, and wireless personal networks.

Kangaslahti, Pekka P.↗

Predicting Quadcopter Noise With The Lattice-Boltzmann Method

From small delivery Unmanned Aircraft Systems (UAS) to short-haul building-to-building aircraft, urban air mobility is gaining traction as a new approach to tackle the problem of transportation in densely populated areas. NASA’s vision for vertical lift vehicles is to capitalize on and improve unique capabilities to greatly benefit the United States’ growing civil flight requirements. This vision is embodied in the Revolutionary Vertical Lift Technology (RVLT)project [1]. Beyond safety, one of the chief concerns of communities where drones are becoming more popular is the noise they generate. Noise will undoubtedly be one of the major obstacles to public acceptance of any new urban air mobility technology. The ability to predict the acoustics of new conceptual aircraft with multiple rotors and complex fuselages is critical to enable the creation of quieter designs. The objective of this research is to build up a better physical understanding of the noise generated by a typical quadcopter drone and what it takes to predict it from first principles using computational fluid dynamics (CFD) with the Lattice-Boltzmann method (LBM). The specific goals are to establish best practices to predict multi-rotor and vehicle interaction noise with LBM, validate these predictions by comparing to wind tunnel measurements, and assess the computational cost necessary to obtain accurate predictions.

Francois Cadieux↗

Vertical Structure and Ice Production Processes of Shallow Convective Postfrontal Clouds over the Southern Ocean in MARCUS. Part I: Observational Study

A study of the vertical structure of postfrontal shallow clouds in the marine boundary layer over the Southern Ocean is presented here. The central question of this two-part study regards cloud phase (liquid/ice) of precipitation, and the associated growth mechanisms. In this first part, data from the Measurements of Aerosols, Radiation, and Clouds over the Southern Ocean (MARCUS) field campaign are analyzed, starting with a 75-h case with continuous sea surface-based thermal instability, modest surface heat fluxes, an open-cellular mesoscale organization, and very few ice nucleating particles (INPs). The clouds are mostly precipitating and shallow (tops mostly around 2 km above sea level), with weak up- and downdrafts, and with cloud-top temperatures generally around –18° to –10°C. Further, the case study is extended to three other periods of postfrontal shallow clouds in MARCUS. While abundant supercooled liquid water is commonly present, an experimental cloud-phase algorithm classifies nearly two-thirds of clouds in the 0° to –5°C layer as containing ice (cloud ice, snow, or mixed phase), implying that much of the precipitation grows through cold-cloud processes. The best predictors of ice presence are cloud-top temperature, cloud depth, and INP concentration. Measures of convective activity and turbulence are found to be poor indicators of ice presence in the studied environment. The water-phase distribution in this cloud regime is explored through numerical simulations in Part II. Significance Statement: Climate models generally predict a lower albedo than observed over the Southern Ocean, and this is largely attributed to a lack of cloudiness, especially in the postfrontal cold sector of midlatitude cyclones. This in turn may be due to an excess of ice in these simulated clouds, resulting in rapid precipitation fallout and an overly brief cloud lifespan. The objective of this study is to examine whether shallow postfrontal clouds over the Southern Ocean are dominated by supercooled drops, or by snow and ice, using data collected by a U.S. Department of Energy Atmospheric Radiation Measurement Mobile Facility deployed aboard an Australian Antarctic supply vessel. We find that these clouds contain much supercooled liquid, even though cloud-top temperatures generally are around –18° to –8°C, and that about two-thirds of the clouds just above the freezing level contain ice. Much of the precipitation appears to grow through cold-cloud processes above the freezing level, rather than drizzle/rain. Updrafts and/or turbulence in convection or in cloud-top generating cells do not initiate much ice, compared to observations elsewhere in a similar temperature range. This may be attributable to the extremely low concentration of ice nucleating particles in this environment. Ultimately, the deepest clouds with the coldest cloud tops are most likely to be ice dominated.

54 ENVIRONMENTAL SCIENCES↗

Redox-controlled backbone dynamics of human cytochrome c revealed by {sup 15}N NMR relaxation measurements

Research highlights: {yields} The dynamic parameters for the backbone dynamics in Cyt c were determined. {yields} The backbone mobility of Cyt c is highly restricted due to the covalently bound heme. {yields} The backbone mobility of Cyt c is more restricted upon the oxidation of the heme. {yields} The redox-dependent dynamics are shown in the backbone of Cyt c. {yields} The backbone dynamics of Cyt c would regulate the electron transfer from Cyt c. -- Abstract: Redox-controlled backbone dynamics in cytochrome c (Cyt c) were revealed by 2D {sup 15}N NMR relaxation experiments. {sup 15}N T{sub 1} and T{sub 2} values and {sup 1}H-{sup 15}N NOEs of uniformly {sup 15}N-labeled reduced and oxidized Cyt c were measured, and the generalized order parameters (S{sup 2}), the effective correlation time for internal motion ({tau}{sub e}), the {sup 15}N exchange broadening contributions (R{sub ex}) for each residue, and the overall correlation time ({tau}{sub m}) were estimated by model-free dynamics formalism. These dynamic parameters clearly showed that the backbone dynamics of Cyt c are highly restricted due to the covalently bound heme that functions as the stable hydrophobic core. Upon oxidation of the heme iron in Cyt c, the average S{sup 2} value was increased from 0.88 {+-} 0.01 to 0.92 {+-} 0.01, demonstrating that the mobility of the backbone is further restricted in the oxidized form. Such increases in the S{sup 2} values were more prominent in the loop regions, including amino acid residues near the thioether bonds to the heme moiety and positively charged region around Lys87. Both of the regions are supposed to form the interaction site for cytochrome c oxidase (CcO) and the electron pathway from Cyt c to CcO. The redox-dependent mobility of the backbone in the interaction site for the electron transfer to CcO suggests an electron transfer mechanism regulated by the backbone dynamics in the Cyt c-CcO system.

60 APPLIED LIFE SCIENCES↗

GROUNDWATER RADIOIODINE: PREVALENCE, BIOGEOCHEMISTRY, AND POTENTIAL REMEDIAL APPROACHES

Iodine-129 ({sup 129}I) has not received as much attention in basic and applied research as other contaminants associated with DOE plumes. These other contaminants, such as uranium, plutonium, strontium, and technetium are more widespread and exist at more DOE facilities. Yet, at the Hanford Site and the Savannah River Site {sup 129}I occurs in groundwater at concentrations significantly above the primary drinking water standard and there is no accepted method for treating it, other than pump-and-treat systems. With the potential arrival of a 'Nuclear Renaissance', new nuclear power facilities will be creating additional {sup 129}I waste at a rate of 1 Ci/gigawatts energy produced. If all 22 proposed nuclear power facilities in the U.S. get approved, they will produce more {sup 129}I waste in seven years than presently exists at the two facilities containing the largest {sup 129}I inventories, ({approx}146 Ci {sup 129}I at the Hanford Site and the Savannah River Site). Hence, there is an important need to fully understand {sup 129}I behavior in the environment to clean up existing plumes and to support the expected future expansion of nuclear power production. {sup 129}I is among the key risk drivers at all DOE nuclear disposal facilities where {sup 129}I is buried, because of its long half-life (16 million years), high toxicity (90% of the body's iodine accumulates in the thyroid), high inventory, and perceived high mobility in the subsurface environment. Another important reason that {sup 129}I is a key risk driver is that there is the uncertainty regarding its biogeochemical fate and transport in the environment. We typically can define {sup 129}I mass balance and flux at sites, but can not accurately predict its response to changes in the environment. This uncertainty is in part responsible for the low drinking water standard, 1 pCi/L {sup 129}I, and the low permissible inventory limits (Ci) at the Savannah River Site, Hanford Site, and the former Yucca Mountain disposal facilities. The objectives of this report are to: (1) compile the background information necessary to understand behavior of {sup 129}I in the environment, (2) discuss sustainable remediation approaches to {sup 129}I contaminated groundwater, and (3) identify areas of research that will facilitate remediation of {sup 129}I contaminated areas on DOE sites. Lines of scientific inquiry that would significantly advance the goals of basic and applied research programs for accelerating {sup 129}I environmental remediation and reducing uncertainty associated with disposal of {sup 129}I waste are: (1) Evaluation of amendments or other treatment systems that can sequester subsurface groundwater {sup 129}I. (2) Develop analytical techniques for measurement of total {sup 129}I that eliminate the necessity of collecting and shipping large samples of groundwater. (3) Develop and evaluate ways to manipulate areas with organic-rich soil, such as wetlands, to maximize {sup 129}I sorption, minimizing releases during anoxic conditions. (4) Develop analytical techniques that can identify the various {sup 129}I species in the subsurface aqueous and solid phases at ambient concentrations and under ambient conditions. (5) Identify the mechanisms and factors controlling iodine-natural organic matter interactions at appropriate environmental concentrations. (6) Understand the biological processes that transform iodine species throughout different compartments of subsurface waste sites and the role that these processes have on {sup 129}I flux.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Comparison of Oxidized Carbon Abundances among Comets

Comets contain relatively well preserved icy material remaining from the epoch of Solar System formation, however the extent to which these ices are modified from their initial state remains a fundamental question in cometary science. As a comet approaches the Sun, sublimation of the ices contained in its nucleus (termed " native ices") releases parent volatiles into the coma, where they can be measured spectroscopically. One means of assessing the degree to which interstellar ices were processed prior to their incorporation into cometary nuclei is to measure the relative abundances of chemically-related parent volatiles. For example, formation of C2H6 by hydrogen atom addition (e.g., to C2H2) on surfaces of ice-mantled grains was proposed to explain the high C2H6 to CH4 abundance observed in C/1996 B2 (Hyakutake) [1]. The large C2H6/CH4 abundance ratios measured universally in comets, compared with those predicted by gas phase production of C2H6, establishes H-atom addition as an important and likely ubiquitous process. CO should also be hydrogenated on grain surfaces. Laboratory irradiation experiments on interstellar ice analogs indicate this to require very low temperatures (T approx. 10-25 K), the resulting yields of H2CO and CH3OH being highly dependent both on hydrogen density (i.e., fluence) and on temperature ([2],[3]). This relatively narrow range in temperature reflects a lack of mobility below 8-10 K on the one hand, and reduced sticking times for H-atoms as grain surfaces are warmed above 20 K on the other. The relative abundances of these three chemically-related molecules in comets provides one measure of the efficiency of H-atom addition to CO on pre-cometary grains (Fig. 1).

DiSanti, M. A.↗

In situ investigation of high-pressure hydrogen-induced swelling in elastomers and its correlation with material properties

The resistance of elastomeric materials to high-pressure hydrogen-induced damage is essential for ensuring the reliability of hydrogen infrastructure. Here, in this study, we systematically investigated the swelling behavior and hydrogen transport properties of four elastomer types – EPDM, NBR, FKM, and HNBR – using a custom in-situ view cell system capable of real-time monitoring during decompression from pressures up to 96.5 MPa. Each elastomer was formulated with and without fillers and plasticizers to assess the effects of formulation on swelling response. Thermal desorption analysis (TDA) was employed to determine equilibrium hydrogen content and diffusion coefficients, providing insight into gas uptake and mobility within each material. Correlation analyses using Pearson and Spearman coefficients revealed that the diffusion coefficient showed a stronger relationship with swelling behavior than hydrogen content, highlighting the dominant role of hydrogen mobility. Filled elastomers, particularly those with carbon black, consistently showed reduced swelling due to enhanced stiffness and reduced diffusivity. These results deepen our understanding of diffuso-mechanical interactions in elastomers and support the rational design of sealing materials for high-pressure hydrogen systems.

EPDM↗

SU-F-I-72: Evaluation of the Ancillary Lead Shielding for Optimizing Radiation Protection in the Interventional Radiology Department

Purpose: The rising complexity of interventional fluoroscopic procedures has resulted in an increase of occupational radiation exposures in the interventional radiology (IR) department. This study assessed the impact of ancillary shielding on optimizing radiation protection for the IR staff. Methods: Scattered radiation measurements were performed in two IR suites equipped with Axiom Artis systems (Siemens Healthcare, Erlangen, Germany) installed in 2006 and 2010. Both rooms had suspended ceiling-mounted lead-acrylic shields of 75×60 cm (Mavig, Munich, Germany) with lead equivalency of 0.5 mm, and under-table drapes of 70×116 cm and 65×70 cm in the newer and the older room respectively. The larger skirt can be wrapped around the table’s corner and in addition the newer suite had two upper shields of 25×55 cm and 25×35 cm. The patient was simulated by 30 cm of acrylic, air kerma rate (AKR) was measured with the 180cc ionization chamber (AccuPro Radcal Corporation, Monrovia, CA, USA) at different positions. The ancillary shields, x-ray tube, image detector, and table height were adjusted by the IR radiologist to simulate various clinical setups. The same exposure parameters were used for all acquisitions. AKR measurements were made at different positions relative to the operator. Results: The AKR measurements demonstrated 91–99% x-ray attenuation by the drapes in both suites. The smaller size of the under-table skirt and absence of the side-drapes in the older room resulted in a 20–50 fold increase of scattered radiation to the operator. The mobile suspended lead-acrylic shield reduced AKR by 90–94% measured at 150–170 cm height. The recommendations were made to replace the smaller under-table skirt and to use the ceiling-mounted shields for all IR procedures. Conclusion: The ancillary shielding may significantly affect radiation exposure to the IR staff. The use of suspended ceiling-mounted shields is especially important for reduction of interventional radiologists’ cranial radiation.

60 APPLIED LIFE SCIENCES↗

Constraints in Semicrystalline Polymers: Using Quasi-isothermal Analysis to Investigate the Mechanisms of Formation and Loss of the Rigid Amorphous Fraction

The nanoscale phase behavior of a semicrystalline polymer is important for mechanical, thermal, optical and other macroscopic properties and can be analyzed well by thermal methods. Using quasi-isothermal (QI) heat capacity measurements, we investigate the formation behavior of the crystalline, mobile amorphous, and rigid amorphous fractions in poly(trimethylene terephthalate), PTT. The crystal and rigid amorphous phases comprise the total solid fraction in PTT at temperatures above T{sub g}, the glass transition temperature of the mobile amorphous fraction. PTT was quasi-isothermally cooled step-wise from the melt which causes its crystalline fraction to be fixed below 451 K. Between the high temperature fulfillment of the T{sub g} step and 451 K, the temperature dependent rigid amorphous fraction (RAF) is completely determined. For PTT, most of the RAF vitrifies between 451 K and T{sub g} step by step during QI cooling after the crystals have formed. The constraints imposed by the crystal surfaces reduce the mobility of the highly entangled polymer chains. We suggest the vitrification of RAF proceeds outward away from the lamellar surfaces in a step by step manner during QI cooling. Upon reheating, devitrification of RAF occurs at a temperature above its previous vitrification temperature, due to the effects of densification brought by physical aging during the long period of quasi-isothermal treatment. Finally, we consider recent concepts related to jamming, which have been suggested to apply to filled polymer systems, and may also be applicable in describing constraints exerted by crystal lamellae upon the RAF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal balance testing of MSAT 2 spacecraft

The present work reports on the recently completed infrared thermal balance/thermal vacuum testing of a MSAT satellite, the first satellite to provide mobile communications service for all of continental North America. MSAT is a two spacecraft program, using a three-axis stabilized Hughes HS-601 series Bus as the vehicle for the Canadian designed Payload. The thermal tests which were performed at the Canadian Space Agency's David Florida Laboratory in Ottawa, Canada, lasted approximately 35 days. The infrared (IR) heating rig was designed to provide radiant heat inputs into seven spacecraft zones during Thermal Vacuum (TV) testing. The TV test was divided into multiple phases. It began with a thermal balance cold phase, followed by a thermal cold cycle and a hot balance phase, complemented by a thermal hot cycle to finish with a thermal cycle with continuous monitoring of the Bus and Payload. The spacecraft's external heat fluxes were provided by IR lamp sources. To ensure flux uniformity, highly reflective baffles and IR East and West faces; the Earth facing (Nadir); and the inside of the thrust cylinder. The aft-end panel heat fluxes were provided by a heated LN2 shroud. The radiation flux intensity on the spacecraft zones from the various rig elements was measured using Monitored Background Radiometers (MBR's) and compared with direct calculations and with pretest predictions. The temperature measurement system was based on Uniform Temperature References (UTR's) located inside the chamber such that all feedthroughs were copper-copper. This system was devised to achieve a temperature measurement accuracy of plus/minus 0.5 C for over 850 thermocouples used in the test. A PC-(QNX-based) based real-time data acquisition system was utilized to provide continuous monitoring of all channels based on a 30-second time scan. In addition, the data acquisition system was able to retrieve telemetry stream from the Satellite Test Equipments (STE) station for real-time data manipulation. Preliminary results showed the test to be successful from both the thermal balance side and the electrical testing side.

Samson, Serge↗

Open-Shell Donor–Acceptor Conjugated Polymers with High Electrical Conductivity

Conductive polymers largely derive their electronic functionality from chemical doping, processes by which redox and charge-transfer reactions form mobile carriers. While decades of research have demonstrated fundamentally new technologies that merge the unique functionality of these materials with the chemical versatility of macromolecules, doping and the resultant material properties are not ideal for many applications. Here, it is demonstrated that open-shell conjugated polymers comprised of alternating cyclopentadithiophene and thiadiazoloquinoxaline units can achieve high electrical conductivities in their native “undoped” form. Spectroscopic, electrochemical, electron paramagnetic resonance, and magnetic susceptibility measurements demonstrate that this donor–acceptor architecture promotes very narrow bandgaps, strong electronic correlations, high-spin ground states, and long-range π-delocalization. A comparative study of structural variants and processing methodologies demonstrates that the conductivity can be tuned up to 8.18 S cm -1 . This exceeds other neutral narrow bandgap conjugated polymers, many doped polymers, radical conductors, and is comparable to commercial grades of poly(styrene-sulfonate)-doped poly(3,4-ethylenedioxythiophene). X-ray and morphological studies trace the high conductivity to rigid backbone conformations emanating from strong π-interactions and long-range ordered structures formed through self-organization that lead to a network of delocalized open-shell sites in electronic communication. The results offer a new platform for the transport of charge in molecular systems.

36 MATERIALS SCIENCE↗

Biological toxicity and environmental hazards associated with PLGA nanoparticles

There have been tremendous advances in nanotechnology. More recently, the use of nanoparticles has expanded to applications including materials, packaging, energy, and medical uses such as drug delivery, diagnostics, and therapeutics. The American Society for Testing and Materials (ASTM) and the International Organization for Standardization (ISO) define nanoparticles as particles with at least one dimension measuring between 1 and 100 nm (2), but this view is generally too limited, and recommendations have been made to consider all materials with a dimension measuring under 1,000 nm as nanoparticles. The biomedical uses of nanoparticles are particularly promising because of their ability to reach and target various sites and organs. However, some nanoparticles can be composed of toxic materials or are limited by issues of biodistribution and bioaccumulation, which have hampered their use in biomedicine. The copolymer poly lactic-co-glycolic acid (PLGA) has gained use in biomedical applications as a delivery system because it is considered biocompatible and can be formulated with controlled degradation in physiological environments. PLGA has a history in biomedicine that dates to the 1970s when biodegradable sutures were developed using PLGA. In addition, the United States (US) Food and Drug Administration (FDA) and the European Medicine Agency (EMA) have approved various PLGA particle formulations as therapeutic delivery vehicles. Interest in biocompatible materials to deliver a range of therapeutic drugs, proteins, nucleic acids, and other molecules has risen recently. In addition to drug delivery, sustained drug release can be achieved by tuning the physical properties of PLGA, such as the molecular weight, ratio of lactic to glycolic acid, drug concentration, stabilizing molecules, and particle size. Given the rise of nanoparticles, human and environmental exposure to them is inevitable as more applications use free, unbound, and highly mobile particles. Although PLGA is generally considered safe, a detailed understanding of how PLGA and the other components used to help formulate this copolymer into a nanoparticle delivery vehicle is useful for assessing potential harmful effects. Despite recent advances in PLGA nanoparticle formulations, residual stabilizing molecules, inconsistent preparations, and batch-to-batch variations can lead to toxicity. Poor preparations of PLGA can lead to common mechanisms of toxicity observed with nanoparticles, such as inflammation and oxidative stress. Consistency in PLGA formulations and accurate methods to evaluate nanoparticle toxicity are needed to ensure safety. In order to better assess PLGA nanoparticles as non-toxic delivery systems, it is critical to understand their physical and chemical properties and the formulation protocols that may introduce toxic components into particles.

Biology, nanoparticle, toxicity↗

Sault Tribe Building Efficiency Audits of Tribally-Owned Governmental Buildings and Residential Tribal Housing

The Tribe is working to reduce energy consumption and expense in Tribally-owned governmental buildings and low income housing sites. In 2009, the Tribe applied to the U. S. Department of Energy for funding to conduct energy audits of Tribally-owned governmental buildings. Findings from the energy audits would define the extent and types of energy efficiency improvements needed, establish a basis for energy priorities, strategies and action plans, and provide a benchmark for measuring improvements from energy efficiency implementations. In 2010, the DOE awarded a grant in the amount of $95,238 to the Tribe to fund the energy audits of nine governmental buildings and to pay for travel expenses associated with attendance and participation at the DOE annual program reviews. In 2011, the Tribe applied for and was awarded a DOE grant in the amount of $75,509 to conduct energy audits of the remaining 30 Tribally-owned governmental buildings. Repeating mobilization steps performed during the first DOE energy audits grant, the Tribe initiated the second round of governmental building energy audits by completing energy auditor procurement. The selected energy auditor successfully passed DOE debarment and Sault Tribe background clearances. The energy audits contract was awarded to U. P. Engineers and Architects, Inc. of Sault Ste. Marie, Michigan. The Tribe continued mobilizing for the energy audits by providing the energy auditor with one year of electric, gas and water utility invoice copies per building, as well as supplemental building information, such as operating hours. The Tribe also contacted building occupants to coordinate scheduling for the on-site energy audit inspections and arranged for facilities management personnel to guide the energy auditor through the buildings and answer questions regarding building systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Elucidating structure and dynamics of crystalline α-zirconium phosphates intercalated with water and methanol by multinuclear solid-state MAS NMR: A comprehensive NMR approach

Solid-state NMR experiments on 2 H, 31 P, 13 C, and 1 H nuclei, including 31 P T 1 , 1 H T 1 , and 1 H T 1ρ measurements, as well as on the kinetics of proton-phosphorus cross-polarization have been performed to characterize the crystalline and amorphous α-zirconium phosphates, which were intercalated with D 2 O and/or CD 3 OD. The 13 C{ 1 H} CP MAS NMR experiment performed for compound 1-CD 3 OD (Zr (HPO 4 ) 2 .0.2CD 3 OD) with carbon cross-polarization via protons of phosphate groups has provided a prove that the methanol was intercalated into the interlayer spaces of this compound. The variable-temperature 2 H solid-echo MAS NMR spectra of intercalated compounds demonstrated that the methanol molecules, in contrast to the mobile water, were immobile, keeping, however, free CD 3 rotations around the C 3 -axis. It has been demonstrated that the intercalated species, D 2 O and CD 3 OD, do not affect the high-frequency motions of the phosphate groups. By utilizing local structural models that satisfy the constraints of the experimental data, it has been suggested that the immobile methanol molecules are located in the cavity between two neighboring layers of the zirconium phosphates. Here, the present work illustrates the reliable criteria in a comprehensive NMR approach to structural and dynamic studies of such systems.

1H↗