Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear Data Evaluation Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Data-Informed Evaluation Framework for Integrated Energy Systems: Insights from Power, Process Heat, and Hydrogen Production Applications

The multi-criteria decision analysis (MCDA) framework provides a systematic evaluation of the diverse preferences and performance metrics associated with alternative solutions. This approach is advantageous over a single-criterion methodology, which are only valid under conditions that assume ceteris paribus or an "apples-to-apples" comparison. However, selecting suitable technologies for integrated energy systems (IES) can be likened to an "apples-to-oranges" comparison, given the heterogeneous factors at stake. These factors include economics and performance parameters, geological compatibility, and environmental impacts. Consequently, past research has often employed a mixture of qualitative and quantitative criteria tailored to the specific interests of each study. While the method proves effective in handling the intricate interplay of criteria, the resulting rankings and scores can vary from study to study. This inconsistency is introduced from the use of subjectively defined thresholds and weights. As a result, decision-makers frequently find it challenging to establish clear connections between specific criteria and the resulting scores, as the transformation of criteria into ordinal scores results in a substantial loss of information. To address this challenge, we introduce a data-informed IES evaluation framework that offers comprehensive, interpretable, and traceable evaluations backed by quantifiable rationale. First, we identified key IES evaluation criteria from a decade of literature, focusing on relevant IES applications in power, process heat, and hydrogen production. We leveraged state-of-the-art cost estimates from the Idaho National Laboratory (INL) and technical data from 78 reactor designs from the International Atomic Energy Agency (IAEA) and the Organization for Economic Co-operation and Development - Nuclear Energy Agency (OECD-NEA). Lastly, we established thresholds by analyzing the mean, variance, root mean square, and slope of values across alternatives, categorizing the preferences of decision-makers into distinct utility functions, such as linear, saturating, exponential, and stepwise. Our approach yielded two main outcomes: (1) it provided consistent assessments across different stakeholder groups and (2) it visualized uncertainties in the decision-making context via comprehensive sensitivity analysis. To demonstrate the impact of our framework, we conducted case studies on 6 reactor designs (AP1000, NuScale, BWRX-300, Xe-100, eVinci, iMSR) for the three applications. Our data-driven framework proved to be highly effective in addressing heterogenous uncertainties faced by varied decision-makers? preferences and IES applications, as well as cost and technical estimates of advanced reactors.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Data-Informed Evaluation Framework for Integrated Energy Systems: Insights from Power, Process Heat, and Hydrogen Production Applications

The multi-criteria decision analysis (MCDA) framework provides a systematic evaluation of the diverse preferences and performance metrics associated with alternative solutions. This approach is advantageous over a single-criterion methodology, which are only valid under conditions that assume ceteris paribus or an "apples-to-apples" comparison. However, selecting suitable technologies for integrated energy systems (IES) can be likened to an "apples-to-oranges" comparison, given the heterogeneous factors at stake. These factors include economics and performance parameters, geological compatibility, and environmental impacts. Consequently, past research has often employed a mixture of qualitative and quantitative criteria tailored to the specific interests of each study. While the method proves effective in handling the intricate interplay of criteria, the resulting rankings and scores can vary from study to study. This inconsistency is introduced from the use of subjectively defined thresholds and weights. As a result, decision-makers frequently find it challenging to establish clear connections between specific criteria and the resulting scores, as the transformation of criteria into ordinal scores results in a substantial loss of information. To address this challenge, we introduce a data-informed IES evaluation framework that offers comprehensive, interpretable, and traceable evaluations backed by quantifiable rationale. First, we identified key IES evaluation criteria from a decade of literature, focusing on relevant IES applications in power, process heat, and hydrogen production. We leveraged state-of-the-art cost estimates from the Idaho National Laboratory (INL) and technical data from 78 reactor designs from the International Atomic Energy Agency (IAEA) and the Organization for Economic Co-operation and Development - Nuclear Energy Agency (OECD-NEA). Lastly, we established thresholds by analyzing the mean, variance, root mean square, and slope of values across alternatives, categorizing the preferences of decision-makers into distinct utility functions, such as linear, saturating, exponential, and stepwise. Our approach yielded two main outcomes: (1) it provided consistent assessments across different stakeholder groups and (2) it visualized uncertainties in the decision-making context via comprehensive sensitivity analysis. To demonstrate the impact of our framework, we conducted case studies on 6 reactor designs (AP1000, NuScale, BWRX-300, Xe-100, eVinci, iMSR) for the three applications. Our data-driven framework proved to be highly effective in addressing heterogenous uncertainties faced by varied decision-makers? preferences and IES applications, as well as cost and technical estimates of advanced reactors.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Attracting Future Radiation Oncologists: An Analysis of the National Resident Matching Program Data Trends From 2004 to 2015

Purpose: A significant physician shortage has been projected to occur by 2025, and demand for oncologists is expected to outpace supply to an even greater degree. In response to this, many have called to increase the number of radiation oncology residency positions. The purpose of this study is to evaluate National Resident Matching Program (NRMP) data for the number of residency positions between 2004 and 2015 as well as the number and caliber of applicants for those positions and to compare radiation oncology to all residency specialties. Methods: NRMP data for all specialties participating in the match, including radiation oncology, were assessed over time examining the number of programs participating in the match, the number of positions offered, and the ratio of applicants to positions in the match from 2004 to 2015. Results: From 2004 to 2015, the number of total programs participating in the match has increased by 26.7%, compared to the increase of 28.6% in the number of radiation oncology programs from during the same time period. The total number of positions offered in the match increased by 53.4%, whereas radiation oncology positions increased by 56.3%, during the same time period. The ratio of applicants (defined as those selecting a specialty as their first or only choice) to positions for all specialties has fluctuated over this time period and has gone from 1.21 to 1.15, whereas radiation oncology experienced a decrease from 1.45 to 1.14. Conclusions: NRMP data suggest that senior medical student applications to radiation oncology are decreasing compared to those of other specialties. If we hope to continue to attract the best and brightest to enter our field, we must continue to support early exposure to radiation oncology, positive educational experiences, and dedicated mentorship to interested medical students.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

VERIFICATION OF THE DEFENSE WASTE PROCESSING FACILITY PROCESS DIGESTION METHOD FOR THE SLUDGE BATCH 6 QUALIFICATION SAMPLE

For each sludge batch that is processed in the Defense Waste Processing Facility (DWPF), the Savannah River National Laboratory (SRNL) confirms applicability of the digestion method to be used by the DWPF lab for elemental analysis of Sludge Receipt and Adjustment Tank (SRAT) receipt samples and SRAT product process control samples.1 DWPF SRAT samples are typically dissolved using a room temperature HF-HNO3 acid dissolution (i.e., DWPF Cold Chem (CC) Method, see DWPF Procedure SW4-15.201) and then analyzed by inductively coupled plasma - atomic emission spectroscopy (ICPAES). In addition to the CC method confirmation, the DWPF lab's mercury (Hg) digestion method was also evaluated for applicability to SB6 (see DWPF procedure 'Mercury System Operating Manual', Manual: SW4-15.204. Section 6.1, Revision 5, Effective date: 12-04-03). This report contains the results and comparison of data generated from performing the Aqua Regia (AR), Sodium Peroxide/Hydroxide Fusion (PF) and DWPF Cold Chem (CC) method digestion of Sludge Batch 6 (SB6) SRAT Receipt and SB6 SRAT Product samples. For validation of the DWPF lab's Hg method, only SRAT receipt material was used and compared to AR digestion results. The SB6 SRAT Receipt and SB6 SRAT Product samples were prepared in the SRNL Shielded Cells, and the SRAT Receipt material is representative of the sludge that constitutes the SB6 Batch or qualification composition. This is the sludge in Tank 51 that is to be transferred into Tank 40, which will contain the heel of Sludge Batch 5 (SB5), to form the SB6 Blend composition. In addition to the 16 elements currently measured by the DWPF, this report includes Hg and thorium (Th) data (Th comprising {approx}2.5 - 3 Wt% of the total solids in SRAT Receipt and SRAT Product, respectively) and provides specific details of ICP-AES analysis of Th. Thorium was found to interfere with the U 367.007 nm emission line, and an inter-element correction (IEC) had to be applied to U data, which is also discussed. The results for any one particular element should not be used in any way to identify the form or speciation of a particular element without support from XRD analysis or used to estimate ratios of compounds in the sludge.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A novel conformity index for intensity modulated radiation therapy plan evaluation

Purpose: Intensity modulated radiation therapy (IMRT) has gained popularity in the treatment of cancers. Manual evaluation of IMRT plans for head-and-neck cancers has been especially challenging necessitating efficient and objective assessment tools. In this work, the authors address this issue by developing a personalized conformity index (CI) for comparison of IMRT plans for head-and-neck cancers and evaluating its plan quality discerning power in comparison with other widely used CIs. Methods: A two-dimensional CI with dose and distance incorporated (CI{sub DD}) was developed using the MATLAB program language, to quantify the planning target volume (PTV) coverage. Valuable information contained in the digital imaging and communication in medicine (DICOM) RT objects were harvested for computation of each of the CI{sub DD} components. Apart from the dose penalty factor, a distance-based exponential function was employed by varying the penalty weight associated with the location of cold spots within the PTV. With the goal of deriving a customized penalty factor, the distances between individual pixel and its nearest PTV boundary was found. Using the exponential function, the impact of distance penalty was substantially larger for cold spots closer to the PTV centroid but petered out quickly wherever they were situated in the vicinity of PTV border. In order to evaluate the CI{sub DD} scoring system, three CT image data sets of nasopharyngeal carcinoma (NPC) patients were collected. Ten IMRT plans with degrading qualities were generated from each dataset and were ranked based on CI{sub DD} and other existing indices. The coefficient of variance was calculated for each dataset to compare the degree of variation. Results: The CI{sub DD} scoring system that considered spatial importance of each voxel within the PTV was successfully developed. The results demonstrated that the CI{sub DD} including four discrete factors could provide accurate rankings of plan quality by examining the relative importance of each cold spot within the PTVs. Apart from the dose penalty factor, a distance-based exponential function was employed taking the specific tumor geometry into account. Compared with other commonly used CIs, the CI{sub DD} resulted in the largest coefficient of variance among the ten IMRT plans for each dataset, indicating that its discerning power was the best among the CIs being compared. Conclusions: The CI{sub DD} scoring system was successfully developed to incorporate patient-specific spatial dose information and provide a geometry-based physical index for comparison of IMRT plans for head-and-neck cancers. By taking individual tumor geometry into account, the superiority of CI{sub DD} in plan discerning power was demonstrated. The use of CI{sub DD} could provide an effective means of benchmarking performance, reducing treatment plan variability, and advancing the quality of current IMRT planning.

60 APPLIED LIFE SCIENCES↗

Energy dependence of fission product yields from 235 U, 238 U, and 239 Pu with monoenergetic neutrons between thermal and 14.8 MeV

Under a joint collaboration between TUNL-LANL-LLNL, a set of absolute fission product yield measurements has been performed. The energy dependence of a number of cumulative fission product yields (FPY) have been measured using quasi-monoenergetic neutron beams for three actinide targets, 235 U, 238 U and 239 Pu, between 0.5 and 14.8 MeV. The FPYs were measured by a combination of fission counting using specially designed dual-fission chambers and γ-ray counting. Each dual-fission chamber is a back-to-back ionization chamber encasing an activation target in the center with thin deposits of the same target isotope in each chamber. This method allows for the direct measurement of the total number of fissions in the activation target with no reference to the fission cross-section, thus reducing uncertainties. γ-ray counting of the activation target was performed on well-shielded HPGe detectors over a period of two months post irradiation to properly identify fission products. Reported are absolute cumulative fission product yields for incident neutron energies of 0.5, 1.37, 2.4, 3.6, 4.6, 5.5, 7.5, 8.9 and 14.8 MeV. Preliminary results from thermal irradiations at the MIT research reactor will also be presented and compared to present data and evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

DOE Advanced Gas Reactor Fuel Development and Qualification Program Overview

Slides discussing the DOE Advanced Gas Reactor Fuel Development and Qualification Program Overview to include focus on LEU UCO TRISO fuel in cylindrical compacts, with data for fuel qualification in support of reactor licensing and a path to establish a domestic commercial TRISO fuel fabrication capability. Timelines from 2004 through 2029. Major program highlights include: Developed fuel performance models based on past observed behavior, Study to understand differences between US and German (“good”) fuel, Developed and improved fuel fabrication and characterization methods, Fabricated lab-scale fuel (AGR-1) with very high quality; excellent in-pile and post-irradiation high-temperature fuel performance, Scale-up coating fabrication (AGR-2) with excellent in-pile performance, AGR-3/4 fuel fabrication and irradiation experiment to assess FP transport behavior, Scale-up matrix fabrication (AGR-5/6/7); & fuel performance evaluation in progress.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Practical Applications of Cosmic Ray Science: Spacecraft, Aircraft, Ground-Based Computation and Control Systems, Exploration, and Human Health and Safety

In this presentation a review of galactic cosmic ray (GCR) effects on microelectronic systems and human health and safety is given. The methods used to evaluate and mitigate unwanted cosmic ray effects in ground-based, atmospheric flight, and space flight environments are also reviewed. However not all GCR effects are undesirable. We will also briefly review how observation and analysis of GCR interactions with planetary atmospheres and surfaces and reveal important compositional and geophysical data on earth and elsewhere. About 1000 GCR particles enter every square meter of Earth’s upper atmosphere every second, roughly the same number striking every square meter of the International Space Station (ISS) and every other low- Earth orbit spacecraft. GCR particles are high energy ionized atomic nuclei (90% protons, 9% alpha particles, 1% heavier nuclei) traveling very close to the speed of light. The GCR particle flux is even higher in interplanetary space because the geomagnetic field provides some limited magnetic shielding. Collisions of GCR particles with atomic nuclei in planetary atmospheres and/or regolith as well as spacecraft materials produce nuclear reactions and energetic/highly penetrating secondary particle showers. Three twentieth century technology developments have driven an ongoing evolution of basic cosmic ray science into a set of practical engineering tools needed to design, test, and verify the safety and reliability of modern complex technological systems and assess effects on human health and safety effects. The key technology developments are: 1) high altitude commercial and military aircraft; 2) manned and unmanned spacecraft; and 3) increasingly complex and sensitive solid state micro-electronics systems. Space and geophysical exploration needs drove the development of the instruments and analytical tools needed to recover compositional and structural data from GCR induced nuclear reactions and secondary particle showers. Finally, the possible role of GCR secondary particle showers in addressing an important homeland security problem, finding nuclear contraband and weapons, will be briefly reviewed.

Koontz, Steve↗

The Component Slope Linear Model for Calculating Intensive Partial Molar Properties: Application to Waste Glasses and Aluminate Solutions - 13099

Partial molar properties are the changes occurring when the fraction of one component is varied while the fractions of all other component mole fractions change proportionally. They have many practical and theoretical applications in chemical thermodynamics. Partial molar properties of chemical mixtures are difficult to measure because the component mole fractions must sum to one, so a change in fraction of one component must be offset with a change in one or more other components. Given that more than one component fraction is changing at a time, it is difficult to assign a change in measured response to a change in a single component. In this study, the Component Slope Linear Model (CSLM), a model previously published in the statistics literature, is shown to have coefficients that correspond to the intensive partial molar properties. If a measured property is plotted against the mole fraction of a component while keeping the proportions of all other components constant, the slope at any given point on a graph of this curve is the partial molar property for that constituent. Actually plotting this graph has been used to determine partial molar properties for many years. The CSLM directly includes this slope in a model that predicts properties as a function of the component mole fractions. This model is demonstrated by applying it to the constant pressure heat capacity data from the NaOHNaAl(OH){sub 4}-H{sub 2}O system, a system that simplifies Hanford nuclear waste. The partial molar properties of H{sub 2}O, NaOH, and NaAl(OH){sub 4} are determined. The equivalence of the CSLM and the graphical method is verified by comparing results determined by the two methods. The CSLM model has been previously used to predict the liquidus temperature of spinel crystals precipitated from Hanford waste glass. Those model coefficients are re-interpreted here as the partial molar spinel liquidus temperature of the glass components. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ion aggregation in high salt solutions: Ion network versus ion cluster

The critical aggregation phenomena are ubiquitous in many self-assembling systems. Ions in high salt solutions could also spontaneously form larger ion aggregates, but their effects on hydrogen-bond structures in water have long been controversial. Here, carrying out molecular dynamics (MD) simulation studies of high salt solutions and comparing the MD simulation results with infrared absorption and pump-probe spectroscopy of O–D stretch mode of HDO in highly concentrated salt solutions and {sup 13}C-NMR chemical shift of S{sup 13}CN{sup −} in KSCN solutions, we find evidence on the onset of ion aggregate and large-scale ion-ion network formation that concomitantly breaks water hydrogen-bond structure in certain salt solutions. Despite that these experimental results cannot provide direct evidence on the three-dimensional morphological structures of ion aggregates, they serve as reference data for verifying MD simulation methods. The MD results suggest that disrupted water hydrogen-bond network is intricately intertwined with ion-ion network. This further shows morphological variation of ion aggregate structures from ion cluster to ion network in high salt solutions that are interrelated to the onset of macroscopic aggregate formation and the water hydrogen-bond structure making and breaking processes induced by Hofmeister ions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Noniterative finite amplitude methods for E 1 and M 1 giant resonances

The finite amplitude method (FAM) is a very efficient approach for solving the fully self-consistent random-phase approximation (RPA) equations. We use FAM to rederive the RPA matrices for Skyrme functionals, calculate the electric dipole ( E 1) and the magnetic dipole ( M 1) giant resonances, and compare the results with available experimental and evaluated data. For the E 1 transitions in heavy nuclei, the calculations reproduce well the resonance energy of the photoabsorption cross sections. In the case of M 1 transitions, we show that the residual interaction does not affect the transition strength of double-magic nuclei, which suggests that the spin terms in the Skyrme force currently neglected in the present computation could improve the agreement between FAM and experimental data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Prediction of countercurrent flow limitation and its uncertainty in a PWR hot leg

In previous studies, we did small-scale air-water experiments for the hot leg and pressurizer surge line in a PWR and three-dimensional (3D) numerical simulations for PWR conditions to evaluate countercurrent flow limitation (CCFL) there, and we developed a one-dimensional (1D) prediction method to generalize prediction of CCFL in a piping system such as the hot leg and pressurizer surge line. In this study, we evaluated computation errors of the 1D prediction method in comparison with CCFL data in the PWR hot leg models with the diameter D and length L of D = 50-650 mm and L/D = 4.5-9.5, and then evaluated uncertainties of the 1D prediction method in comparison with 3D numerical simulations for PWR conditions with D = 750 mm and L/D = 8.6. We found the computation errors were within the difference of dC = ±0.05 for the CCFL constant of C = 0.63 in the correlation with the Wallis parameters, but the computation errors include experimental errors and they are not uncertainties for the PWR conditions. The total uncertainty of the 1D computations for the actual PWR hot leg (including effects of the diameter and fluid properties) was estimated to be dC = ±0.035. The CCFL correlation and its uncertainty of dC = ±0.035 derived from the 1D prediction method were very close to those previously obtained from CCFL data and 3D simulations (dC = ±0.03). (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Tensor-decomposition techniques for ab initio nuclear structure calculations: From chiral nuclear potentials to ground-state energies

The computational resources needed to generate the ab initio solution of the nuclear many-body problem for increasing mass number and/or accuracy necessitates innovative developments to improve upon (i) the storage of many-body operators and (ii) the scaling of many-body methods used to evaluate nuclear observables. The storing and efficient handling of many-body operators with high particle ranks is currently one of the major bottlenecks limiting the applicability range of ab initio studies with respect to mass number and accuracy. Recently, the application of tensor decomposition techniques to many-body tensors has proven highly beneficial to reduce the computational cost of ab initio calculations in quantum chemistry and solid-state physics. The impact of applying state-of-the-art tensor factorization techniques to modern nuclear Hamiltonians derived from chiral effective field theory is investigated. Subsequently, the error induced by the tensor decomposition of the input Hamiltonian on ground-state energies of closed-shell nuclei calculated via second-order many-body perturbation theory is benchmarked. The first proof-of-principles application of tensor-decomposition techniques to the nuclear Hamiltonian is performed. Two different tensor formats are investigated by systematically benchmarking the approximation error on matrix elements stored in various bases of interest. The analysis is achieved while including normal-ordered three-nucleon interactions that are nowadays used as input to the most advanced ab initio calculations in medium-mass nuclei. With the aid of the factorized Hamiltonian, the second-order perturbative correction to ground-state energies is decomposed and the scaling properties of the underlying tensor network are discussed. The employed tensor formats are found to lead to an efficient data compression of two-body matrix elements of the nuclear Hamiltonian. In particular, the sophisticated tensor hypercontraction scheme yields low tensor ranks with respect to both harmonic-oscillator and Hartree-Fock single-particle bases. It is found that the tensor rank depends on the two-body total angular momentum J for which one performs the decomposition, which is itself directly related to the sparsity of the corresponding tensor. Furthermore, including normal-ordered two-body contributions originating from three-body interactions does not compromise the efficient data compression. Ultimately, the use of factorized matrix elements authorizes controlled approximations of the exact second-order ground-state energy corrections. In particular, a small enough error is obtained from low-rank factorizations in He4,O16, and Ca40. It is presently demonstrated that tensor-decomposition techniques can be efficiently applied to systematically approximate the nuclear many-body Hamiltonian in terms of lower-rank tensors. Beyond the input Hamiltonian, tensor-decomposition techniques can be envisioned to scale down the cost of state-of-the-art nonperturbative many-body methods in order to extend ab initio studies to (i) higher precisions, (ii) larger masses, and (iii) nuclei of doubly open-shell character.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Factors for conversion between human and automatic read-outs of CDMAM images

Purpose: According to the European protocol for the quality control of the physical and technical aspects of mammography screening (EPQCM) image quality of digital mammography devices has to be assessed using human evaluation of the CDMAM contrast-detail phantom. This is accomplished by the determination of threshold thicknesses of gold disks with different diameters (0.08-2 mm) and revealed to be very time consuming. Therefore a software solution based on a nonprewhitening matched filter (NPW) model was developed at University of Nijmegen. Factors for the conversion from automatic to human readouts have been determined by Young et al.[Proc. SPIE 614206, 1-13 (2006) and Proc. SPIE 6913, 69131C1 (2008)] using a huge amount of data of both human and automatic readouts. These factors depend on the observer groups and are purely phenomenological. The authors present an alternative approach to determine the factors by using the Rose observer model. Methods: Their method uses the Rose theory which gives a relationship between threshold contrast, diameter of the object and number of incident photons. To estimate the conversion factors for the five diameters from 0.2 to 0.5 mm they exposed with five different current-time products which resulted in 25 equations with five unknowns. Results: The theoretical conversion factors (in dependence of the diameters) amounted to be 1.61 {+-} 0.02 (0.2 mm diameter), 1.67 {+-} 0.02 (0.25 mm), 1.85 {+-} 0.02 (0.31 mm), 2.09 {+-} 0.02 (0.4 mm), and 2.28 {+-} 0.02 (0.5 mm). The corresponding phenomenological factors found in literature are 1.74 (0.2 mm), 1.78 (0.25 mm), 1.83 (0.31 mm), 1.88 (0.4 mm), and 1.93 (0.5 mm). Conclusions: They transferred the problem of determining the factors to a well known observer model which has been examined for many years and is also well established. This method reveals to be reproduceable and produces factors comparable to the phenomenological ones.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental evaluation of the extended Dytlewski-style dead time correction formalism for neutron multiplicity counting

Over the past few decades, neutron multiplicity counting has played an integral role in Special Nuclear Material (SNM) characterization pertaining to nuclear safeguards. Current neutron multiplicity analysis techniques use singles, doubles, and triples count rates because a methodology to extract and dead time correct higher order count rates (i.e. quads and pents) was not fully developed. This limitation is overcome by the recent extension of a popular dead time correction method developed by Dytlewski. This extended dead time correction algorithm, named Dytlewski-Croft-Favalli (DCF), is detailed in reference Croft and Favalli (2017), which gives an extensive explanation of the theory and implications of this new development. Dead time corrected results can then be used to assay SNM by inverting a set of extended point model equations which as well have only recently been formulated. Here, we discuss and present the experimental evaluation of practical feasibility of the DCF dead time correction algorithm to demonstrate its performance and applicability in nuclear safeguards applications. In order to test the validity and effectiveness of the dead time correction for quads and pents, 252 Cf and SNM sources were measured in high efficiency neutron multiplicity counters at the Los Alamos National Laboratory (LANL) and the count rates were extracted up to the fifth order and corrected for dead time. To assess the DCF dead time correction, the corrected data is compared to traditional dead time correction treatment within INCC. In conclusion, the DCF dead time correction is found to provide adequate dead time treatment for broad range of count rates available in practical applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neural MUSE Analysis

Researchers at Oak Ridge National Laboratory (ORNL) created data as part of the MUSE (Multi-Agency Urban Search Experiment Detector and Algorithm Test Bed) project simulating illicit nuclear materials located in various buildings along a road. In the simulation, a truck containing a radiation detector drives down the road gathering listmode data (counting the and energy of incident gamma radiation). Building materials, source shielding, driving speed, truck direction, truck location on the road, source type, and source placement are all varied between runs of the data set. This data was created using deterministic neutron transport and Monte Carlo methods through a combination of SCALE, MAVRIC, MCNP, and GADRAS. As part of a follow-on NA-22 project, two Kaggle competitions were created to determine the best algorithms for finding and identifying gamma sources in this simulated urban environment. The winning algorithm was neural network-based and had a test accuracy of 76.4% accuracy for source identification. This work seeks to build upon this work and improve the results through the application of novel machine learning techniques. As a first step, the data was classified by a simple Convolutional Neural Network (CNN) To accomplish this, the data was first preprocessed into “waterfall plots.” These plots are composed of energy vs count plots that are stacked vertically to show progression in time. The horizontal axis indicating the particle energy incorporated user defined bin spacing with options for in linear-, logarithmic-, square root-, and user-spaced bins. The z or color dimension showed the number of counts corresponding the energy-time combination. This data was then used to generate more data, by generating a local estimate of the mean of the distribution for a bin and then randomly re-sampling that bin from a Poisson distribution. Once all of this data was generated, it was fed into a well-known CNN architecture, ResNet50. The output layer of this model was removed and replaced with layers corresponding to the shape desired isotope outputs. The provided training data was used to train the classifier and the remaining testing data was used to evaluate the model. Results are soon to be forthcoming.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of Uranium Measurements in Water by Various Methods - 13571

In December 2000, EPA amended its drinking water regulations for radionuclides by adding a Maximum Contaminant Level (MCL) for uranium (so called MCL Rule)[1] of 30 micrograms per liter (μg/L). The MCL Rule also included MCL goals of zero for uranium and other radionuclides. Many radioactively contaminated sites must test uranium in wastewater and groundwater to comply with the MCL rule as well as local publicly owned treatment works discharge limitations. This paper addresses the relative sensitivity, accuracy, precision, cost and comparability of two EPA-approved methods for detection of total uranium: inductively plasma/mass spectrometry (ICP-MS) and alpha spectrometry. Both methods are capable of measuring the individual uranium isotopes U-234, U- 235, and U-238 and both methods have been deemed acceptable by EPA. However, the U-238 is by far the primary contributor to the mass-based ICP-MS measurement, especially for naturally-occurring uranium, which contains 99.2745% U-238. An evaluation shall be performed relative to the regulatory requirement promulgated by EPA in December 2000. Data will be garnered from various client sample results measured by ALS Laboratory in Fort Collins, CO. Data shall include method detection limits (MDL), minimum detectable activities (MDA), means and trends in laboratory control sample results, performance evaluation data for all methods, and replicate results. In addition, a comparison will be made of sample analyses results obtained from both alpha spectrometry and the screening method Kinetic Phosphorescence Analysis (KPA) performed at the U.S. Army Corps of Engineers (USACE) FUSRAP Maywood Laboratory (UFML). Many uranium measurements occur in laboratories that only perform radiological analysis. This work is important because it shows that uranium can be measured in radiological as well as stable chemistry laboratories and it provides several criteria as a basis for comparison of two uranium test methods. This data will indicate which test method is the most accurate and most cost effective. This paper provides a benefit to Formerly Utilized Sites Remedial Action Program (FUSRAP) and other Department of Defense (DOD) programs that may be performing uranium measurements. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of high-energy brachytherapy source electronic disequilibrium and dose from emitted electrons

Purpose: The region of electronic disequilibrium near photon-emitting brachytherapy sources of high-energy radionuclides ({sup 60}Co, {sup 137}Cs, {sup 192}Ir, and {sup 169}Yb) and contributions to total dose from emitted electrons were studied using the GEANT4 and PENELOPE Monte Carlo codes. Methods: Hypothetical sources with active and capsule materials mimicking those of actual sources but with spherical shape were examined. Dose contributions due to source photons, x rays, and bremsstrahlung; source {beta}{sup -}, Auger electrons, and internal conversion electrons; and water collisional kerma were scored. To determine if conclusions obtained for electronic equilibrium conditions and electron dose contribution to total dose for the representative spherical sources could be applied to actual sources, the {sup 192}Ir mHDR-v2 source model (Nucletron B.V., Veenendaal, The Netherlands) was simulated for comparison to spherical source results and to published data. Results: Electronic equilibrium within 1% is reached for {sup 60}Co, {sup 137}Cs, {sup 192}Ir, and {sup 169}Yb at distances greater than 7, 3.5, 2, and 1 mm from the source center, respectively, in agreement with other published studies. At 1 mm from the source center, the electron contributions to total dose are 1.9% and 9.4% for {sup 60}Co and {sup 192}Ir, respectively. Electron emissions become important (i.e., >0.5%) within 3.3 mm of {sup 60}Co and 1.7 mm of {sup 192}Ir sources, yet are negligible over all distances for {sup 137}Cs and {sup 169}Yb. Electronic equilibrium conditions along the transversal source axis for the mHDR-v2 source are comparable to those of the spherical sources while electron dose to total dose contribution are quite different. Conclusions: Electronic equilibrium conditions obtained for spherical sources could be generalized to actual sources while electron contribution to total dose depends strongly on source dimensions, material composition, and electron spectra.

61 RADIATION PROTECTION AND DOSIMETRY↗