SiC MOSFET Based Modular Universal Power Electronics Regulator

A modular and scalable SiC MOSFET based universal power electronics regulator (UPER) allows coordinated integration of energy resources and loads, elimination of extra power conversion stages, and allowance of more sources or loads added with a simple plug and play feature. A comprehensive investigation has been conducted in term of the typical distributed generations and loads employed in buildings, in order to outline a detailed specification for UPER. Thus, a common DC bus voltage of 500 V and power rating of 3 kW are dedicatedly selected. The UPER hardware design and implementation are completely illustrated, including the static and dynamic characterization of the employed SiC MOSFET. The dedicated universal power cell and Plug-and-Play gate driver performs reliable continuous operation even exposed to an extreme fast switching speed (> 100 V/ns). The continuous operation of buck mode verified the UPER hardware development at 50 kHz with an overall efficiency of 98.19%. A new voltage polarity reversal phenomenon was also discovered in the verification of the isolated DAB stage with planar transformers.

Zheng, Sheng↗

In situ measurements of reactions in a glass-forming batch by X-ray and neutron diffraction

We report the batch materials used in glass production are often too coarse to allow phase evolution measurements by in situ high-temperature x-ray diffraction (HTXRD). Reducing the particle sizes to accommodate these measurements changes the reaction kinetics and can alter the reaction pathway. Unlike conventional laboratory XRD, which operates in reflection mode and analyzes the surface region of finely ground powder, neutron diffraction can be used to characterize as-received batch materials by means of an intense beam which penetrates through a bulk sample. In this study, the phase evolution in a glass-forming batch made with fine batch materials was probed in situ by both HTXRD and time-of-flight neutron diffraction to determine the similarities and differences between measurements by the two techniques. Therefore, the same composition, prepared using the coarser, as-received size distributions of the same batch materials, was studied by both techniques, demonstrating the unique capability of neutron diffraction to analyze material which is too coarse for the HTXRD, and to reveal the effect of the particle size distribution on the reaction kinetics.

36 MATERIALS SCIENCE↗

Novel strategy for low-temperature, high-rate growth of dense, hard, and stress-free refractory ceramic thin films

Growth of fully dense refractory thin films by means of physical vapor deposition (PVD) requires elevated temperatures T{sub s} to ensure sufficient adatom mobilities. Films grown with no external heating are underdense, as demonstrated by the open voids visible in cross-sectional transmission electron microscopy images and by x-ray reflectivity results; thus, the layers exhibit low nanoindentation hardness and elastic modulus values. Ion bombardment of the growing film surface is often used to enhance densification; however, the required ion energies typically extract a steep price in the form of residual rare-gas-ion-induced compressive stress. Here, the authors propose a PVD strategy for the growth of dense, hard, and stress-free refractory thin films at low temperatures; that is, with no external heating. The authors use TiN as a model ceramic materials system and employ hybrid high-power pulsed and dc magnetron co-sputtering (HIPIMS and DCMS) in Ar/N{sub 2} mixtures to grow dilute Ti{sub 1−x}Ta{sub x}N alloys on Si(001) substrates. The Ta target driven by HIPIMS serves as a pulsed source of energetic Ta{sup +}/Ta{sup 2+} metal–ions, characterized by in-situ mass and energy spectroscopy, while the Ti target operates in DCMS mode (Ta-HIPIMS/Ti-DCMS) providing a continuous flux of metal atoms to sustain a high deposition rate. Substrate bias V{sub s} is applied in synchronous with the Ta-ion portion of each HIPIMS pulse in order to provide film densification by heavy-ion irradiation (m{sub Ta} = 180.95 amu versus m{sub Ti} = 47.88 amu) while minimizing Ar{sup +} bombardment and subsequent trapping in interstitial sites. Since Ta is a film constituent, primarily residing on cation sublattice sites, film stress remains low. Dense Ti{sub 0.92}Ta{sub 0.08}N alloy films, 1.8 μm thick, grown with T{sub s} ≤ 120 °C (due to plasma heating) and synchronized bias, V{sub s} = 160 V, exhibit nanoindentation hardness H = 25.9 GPa and elastic modulus E = 497 GPa compared to 13.8 and 318 GPa for underdense Ti-HIPIMS/Ti-DCMS TiN reference layers (T{sub s} < 120 °C) grown with the same V{sub s}, and 7.8 and 248 GPa for DCMS TiN films grown with no applied bias (T{sub s} < 120 °C). Ti{sub 0.92}Ta{sub 0.08}N residual stress is low, σ = −0.7 GPa, and essentially equal to that of Ti-HIPIMS/Ti-DCMS TiN films grown with the same substrate bias.

36 MATERIALS SCIENCE↗

SU-F-BRE-11: Neutron Measurements Around the Varian TrueBeam Linac

Purpose: With the emergence of flattening filter free (FFF) photon beams, several authors have noted many advantages to their use. One such advantage is the decrease in neutron production by photonuclear reactions in the linac head. In the present work we investigate the reduction in neutrons from a Varian TrueBeam linac using the Nested Neutron Spectrometer (NNS, Detec). The neutron spectrum, total fluence and source strength were measured and compared for 10 MV with and without flattening filter and the effect of moderation by the room and maze was studied for the 15 MV beam. Methods: The NNS, similar to traditional Bonner sphere detectors but operated in current mode, was used to measure the neutron fluence and spectrum. The NNS was validated for use in high dose rate environments using Monte Carlo simulations and calibrated at NIST and NRC Canada. Measurements were performed at several positions within the treatment room and maze with the linac jaws closed to maximize neutron production. Results: The measurements showed a total fluence reduction between 35-40% in the room and maze when the flattening filter was removed. The neutron source strength Qn was calculated from in-room fluence measurements and was found to be 0.042 × 10{sup 2} n/Gy, 0.026 × 10{sup 2} n/Gy and 0.59 × 101{sup 2} n/Gy for the 10 MV, the 10 MV FFF and 15 MV beams, respectively. We measured ambient equivalent doses of 11 mSv/hr, 7 mSv/hr and 218 mSv/hr for the 10 MV, 10 MV FFF and 15 MV by the head. Conclusion: Our measurements revealed a decrease in total fluence, neutron source strength and equivalent dose of approximately 35-40% across the treatment room for the FFF compared to FF modes. This demonstrates, as expected, that the flattening filter is a major component of the neutron production for the TrueBeam. The authors greatly acknowledge support form the Canadian Nuclear Commission and the Natural Sciences and Engineering Research Council of Canada through the CREATE program. Co-authors Dubeau and Witharana are employees of Detec (Gatineau, Quebec), manufacturer of the Nested Neutron Spectrometer.

07 ISOTOPE AND RADIATION SOURCES↗

TH-C-19A-02: Characterization of An Actively Controlled Graphite Probe Calorimeter

Purpose: To construct and experimentally evaluate the performance of a miniature probe-format graphite calorimeter (GPC) with built-in active control. The GPC is the first ever calorimeter designed specifically for routine clinical use. Methods: The original GPC design, developed as part of our previous work, was modified to accommodate a micro-thin, resistive heating element and sensing thermistors embedded in the outermost graphite layer. A software-based process control loop was written to maintain a predefined set point temperature throughout the detector by precisely modulating the current flowing through the resistive element. Continuous feedback is provided to the controller by the additional thermistors. A functioning prototype was constructed in-house and operated in adiabatic mode in a 6 MV photon beam. Ten sets of measurements of varying duration (10 to 60 seconds) and repetition rate (200 to 600 MU/min) were analyzed. Reproducibility, linearity and dose rate dependence were assessed. Results: A total of 47 individual measurements were performed using the active GPC. The reproducibility, defined here as the sample standard deviation weighted across all 10 measurement sets, was found to be 0.37%. Similarly, the standard error (type A uncertainty) was 0.17%. Linearity was quantified by plotting signal as a function of monitor units delivered at 600 MU/min. The adjusted R-square of the resulting linear fit was 0.9996. Dose rate dependence, evaluated as the change in normalized response (signal/MU) as a function of repetition rate, was found to be statistically insignificant. Conclusions: The incorporation of active control has resulted in a marked improvement in the GPC's reproducibility and it allows the user to now perform measurements within minutes of setup. With this refinement, it is estimated that the overall standard uncertainty in the absolute determination of dose to water is 1%, making the GPC comparable to a calibrated ionization chamber. This research has received financial support from Sun Nuclear Corporation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sci—Fri PM: Dosimetry—02: A Nested Neutron Spectrometer to Measure Neutron Spectra in Radiotherapy

During high-energy radiotherapy treatments, neutrons are produced in the head of the linac through photonuclear interactions. This has been a concern for many years as photoneutrons contribute to the accepted, yet unwanted, out-of-field doses that pose an iatrogenic risk to patients and an occupational risk to personnel. Presently, in-room neutron measurements are difficult and time-consuming and have traditionally been carried out using Bonner spheres with activation foils and TLDs. In this work, a new detector, the Nested Neutron Spectrometer (NNS) is tested for use in radiotherapy bunkers. The NNS is designed for easy handling and is more practical than the traditional Bonner spheres. The NNS, operated in current mode, was used to measure the dose equivalent, average energy and energy spectrum at several positions in a radiotherapy bunker. The average energy and spectra were compared to Monte Carlo simulations while the dose equivalent was compared to bubble detector measurements. The average energies, as measured by the NNS and Monte Carlo simulations, differed by approximately 30% across the bunker. Measurements of the dose equivalent using the NNS and the bubble detectors agreed within 50% in the maze and less than 10% close to the linac head. Apart from some discrepancies at thermal energies, we also found reasonable agreement between NNS-measured and Monte Carlo-simulated spectra at a number of locations within our radiotherapy bunker. Our results demonstrate that the NNS is a suitable detector to be used in high dose-rate radiotherapy environments.

07 ISOTOPE AND RADIATION SOURCES↗

Registration of clinical volumes to beams-eye-view images for real-time tracking

Purpose: The authors combine the registration of 2D beam’s eye view (BEV) images and 3D planning computed tomography (CT) images, with relative, markerless tumor tracking to provide automatic absolute tracking of physician defined volumes such as the gross tumor volume (GTV). Methods: During treatment of lung SBRT cases, BEV images were continuously acquired with an electronic portal imaging device (EPID) operating in cine mode. For absolute registration of physician-defined volumes, an intensity based 2D/3D registration to the planning CT was performed using the end-of-exhale (EoE) phase of the four dimensional computed tomography (4DCT). The volume was converted from Hounsfield units into electron density by a calibration curve and digitally reconstructed radiographs (DRRs) were generated for each beam geometry. Using normalized cross correlation between the DRR and an EoE BEV image, the best in-plane rigid transformation was found. The transformation was applied to physician-defined contours in the planning CT, mapping them into the EPID image domain. A robust multiregion method of relative markerless lung tumor tracking quantified deviations from the EoE position. Results: The success of 2D/3D registration was demonstrated at the EoE breathing phase. By registering at this phase and then employing a separate technique for relative tracking, the authors are able to successfully track target volumes in the BEV images throughout the entire treatment delivery. Conclusions: Through the combination of EPID/4DCT registration and relative tracking, a necessary step toward the clinical implementation of BEV tracking has been completed. The knowledge of tumor volumes relative to the treatment field is important for future applications like real-time motion management, adaptive radiotherapy, and delivered dose calculations.

60 APPLIED LIFE SCIENCES↗

SU-E-P-15: Technique Factor Modulation and Reference Plane Air Kerma Rates in Response to Simulated Patient Thickness Variations for a Sample of Current Generation Fluoroscopes

Purpose: To evaluate and compare approaches to technique factor modulation and air kerma rates in response to simulated patient thickness variations for four state-of-the-art and one previous-generation interventional fluoroscopes. Methods: A polymethyl methacrylate (PMMA) phantom was used as a tissue surrogate for the purposes of determining fluoroscopic reference plane air kerma rates, kVp, mA, and spectral filtration over a wide range of simulated tissue thicknesses. Data were acquired for each fluoroscopic and acquisition dose curve within a default abdomen or body imaging protocol. Results: The data obtained indicated vendor- and model-specific variations in the approach to technique factor modulation and reference plane air kerma rates across a range of tissue thicknesses. Some vendors have made hardware advances increasing the radiation output capabilities of their fluoroscopes; this was evident in the acquisition air kerma rates. However, in the imaging protocol evaluated, all of the state-of-the-art systems had relatively low air kerma rates in the fluoroscopic low-dose imaging mode as compared to the previous-generation unit. Each of the newest-generation systems also employ copper filtration in the selected protocol in the acquisition mode of imaging; this is a substantial benefit, reducing the skin entrance dose to the patient in the highest dose-rate mode of fluoroscope operation. Conclusion: Understanding how fluoroscopic technique factors are modulated provides insight into the vendor-specific image acquisition approach and provides opportunities to optimize the imaging protocols for clinical practice. The enhanced radiation output capabilities of some of the fluoroscopes may, under specific conditions, may be beneficial; however, these higher output capabilities also have the potential to lead to unnecessarily high dose rates. Therefore, all parties involved in imaging, including the clinical team, medical physicists, and imaging vendors, must work together to ensure that adequate but not excessive radiation doses are used.

60 APPLIED LIFE SCIENCES↗

SU-F-T-511: Feasibility Study of Using Flattening-Filter-Free Photon Beams to Deliver Conventional Flat Beam

Purpose: Various dosimetric benefits such as increased dose rate, and reduced leakage and out of field dose has led to the growth of FFF technology in the clinic. In this study, we concentrate on investigating the feasibility of using flattening-filter-free (FFF) beams to deliver conventional flat beams (CFB), since completely getting rid of the flattening-filter module from the gantry head can not only simplify the gantry design but also decrease the workload on machine maintain and quality assurance. Methods: The sliding window based IMRT technique was utilized to generate the CFB from the FFF beam for various beam configurations on the Elekta Versa HD. The flat beam reproducibility and MU efficiency were compared for each beam configuration among FFF planning, delivery and CFB planning. Results: Compared to the CFB plan, the 3%3mm passing rates of the FFF beams from both measurement and plan are 100% and 95%(or better) for 15×15 cm{sup 2} or smaller field size and for any field size greater than 15×15 cm{sup 2}at 10 cm depth, respectively. The largest discrepancy is about 5% and typically appears at the field shoulder area. The MU increase average was 80% for FFF compared to CFB, however has a minimal impact on treatment delivery time. Conclusion: The ability to deliver conventional flat treatments is not absent when operating in FFF mode. With proper TPS manipulation and beam modulation, FFF mode can achieve reasonable flat profiles and comparable dose coverage as CFB does for various conventional treatment techniques, such as four field box, or long spine treatment techniques. The ability to deliver most clinical treatments from the same treatment unit, will allow for less quality assurance as well as maintenance, and completely eliminate the need for the flattening filter on modern linacs.

60 APPLIED LIFE SCIENCES↗

Poster - 30: Use of a Hazard-Risk Analysis for development of a new eye immobilization tool for treatment of choroidal melanoma

Purpose: Our treatment for choroidal melanoma utilizes the GTC frame. The patient looks at a small LED to stabilize target position. The LED is attached to a metal arm attached to the GTC frame. A camera on the arm allows therapists to monitor patient compliance. To move to mask-based immobilization we need a new LED/camera attachment mechanism. We used a Hazard-Risk Analysis (HRA) to guide the design of the new tool. Method: A pre-clinical model was built with input from therapy and machine shop personnel. It consisted of an aluminum frame placed in aluminum guide posts attached to the couch top. Further development was guided by the Department of Defense Standard Practice - System Safety hazard risk analysis technique. Results: An Orfit mask was selected because it allowed access to indexes on the couch top which assist with setup reproducibility. The first HRA table was created considering mechanical failure modes of the device. Discussions with operators and manufacturers identified other failure modes and solutions. HRA directed the design towards a safe clinical device. Conclusion: A new immobilization tool has been designed using hazard-risk analysis which resulted in an easier-to-use and safer tool compared to the initial design. The remaining risks are all low probability events and not dissimilar from those currently faced with the GTC setup. Given the gains in ease of use for therapists and patients as well as the lower costs for the hospital, we will implement this new tool.

60 APPLIED LIFE SCIENCES↗

Simultaneous Implementation of NiSWAP and NSWAP Gates Using N + 1 Qubits in a Cavity or Coupled to a Circuit

We propose an effective method to realize NiSWAP and NSWAP gates in a cavity or coupled to a circuit driven by a strong microwave field. The scheme is insensitive to the initial state of the resonator mode, and the operation time is independent of the number of qubits involved in the gates operations. These logic gates can be realized in a time much shorter than the radiative time and the lifetime of the cavity photon, and can be realized in a time (nanosecond-scale) much smaller than the decoherence time and the dephasing time (microsecond-scale) in circuit QED. Numerical simulation under the influence of the gates operations shows that the scheme can be implemented with high fidelity. We also propose a detailed procedure and experimentally analyze its feasibility. Moreover, the scheme might be experimentally achieved efficiently within current state-of-the-art technology.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Corpuscular Diagnosis of the Plasma of Penning Ion Sources

The results of the studies of the energy distribution and atomic-molecular composition of the ions emitted from two Penning ion sources are presented. The transitions between different discharge modes, when the operating pressure and voltage on the anode are changed, are investigated. The energy spectra and mass-charge spectra are measured and the dependences of the fraction of atomic ions on the discharge parameters are determined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First results from plasma density measurements in the FTU tokamak by means of a two-frequency pulsed time-of-flight refractometer

A pulsed time-of-flight refractometer was developed and tested to determine the mean plasma density in the T-11M tokamak by measuring the propagation time of nanosecond microwave pulses in plasma. Later, it was also proposed to use such an instrument to measure and control the mean plasma density in the ITER tokamak by probing the plasma with an extraordinary wave, the electric field of which is perpendicular to the magnetic field in plasma, in the transparency window at frequencies of 50-100 GHz. To avoid the effect of the density profile shape on the measurement results in the nonlinear mode of refractometer operation (near the cutoff), a system operating at two different probing frequencies was developed and tested. Such a system provides two values of the time delay, which can be used to estimate the peaking factor of the density distribution {alpha} and correctly determine the linear density Left-Pointing-Angle-Bracket Nl Right-Pointing-Angle-Bracket , regardless of the density profile (assuming a smooth density profile of the form of N({rho}) = N(0)(1 - {rho}{sup 2}){sup {alpha}}, where N(0) is the central plasma density and {rho} = r/a is the normalized plasma radius). The first experiments on density measurements in the FTU tokamak performed with this refractometer are described, and results from these experiments are presented. The formation of a thin dense plasma layer in the zone of a strong magnetic field (the so-called MARFE layer) at a relatively low (for FTU) plasma density of {approx}6 Multiplication-Sign 10{sup 19} m{sup -3} was detected. The thickness of this layer, determined from the refractometry data, agrees well with the data obtained using a digital camera.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Asymmetry of the Balmer-alpha line shape and recovery of the effective hydrogen temperature in the tokamak scrape-off layer

An algorithm for recovering the effective temperature of atoms of hydrogen (and its isotopes) in the tokamak scrape-off layer from the asymmetry of the Balmer-alpha line shape is proposed. The algorithm is based on the parametrization of the asymmetry of the line shape caused by the nonlocal character of neutral hydrogen flux from the wall into the tokamak plasma. The accuracy of the algorithm is tested against the results of simulations of the velocity distribution function of deuterium neutrals in the scrape-off layer by the EIRENE code with the use of the source data on the main plasma component in the quasi-stationary stage of the inductive mode of ITER operation calculated by the SOLPS4.3 (B2-EIRENE) code.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Increase the threshold voltage of high voltage GaN transistors by low temperature atomic hydrogen treatment

High-electron-mobility transistors (HEMTs) based on AlGaN/GaN epitaxial heterostructures are a promising element base for the fabrication of high voltage electronic devices of the next generation. This is caused by both the high mobility of charge carriers in the transistor channel and the high electric strength of the material, which makes it possible to attain high breakdown voltages. For use in high-power switches, normally off-mode GaN transistors operating under enhancement conditions are required. To fabricate normally off GaN transistors, one most frequently uses a subgate region based on magnesium-doped p-GaN. However, optimization of the p-GaN epitaxial-layer thickness and the doping level makes it possible to attain a threshold voltage of GaN transistors close to V{sub th} = +2 V. In this study, it is shown that the use of low temperature treatment in an atomic hydrogen flow for the p-GaN-based subgate region before the deposition of gate-metallization layers makes it possible to increase the transistor threshold voltage to V{sub th} = +3.5 V. The effects under observation can be caused by the formation of a dipole layer on the p-GaN surface induced by the effect of atomic hydrogen. The heat treatment of hydrogen-treated GaN transistors in a nitrogen environment at a temperature of T = 250°C for 12 h reveals no degradation of the transistor’s electrical parameters, which can be caused by the formation of a thermally stable dipole layer at the metal/p-GaN interface as a result of hydrogenation.

36 MATERIALS SCIENCE↗

First- and Second-Order Methods for Online Convolutional Dictionary Learning

Convolutional sparse representations are a form of sparse representation with a structured, translation-invariant dictionary. Most convolutional dictionary learning algorithms to date operate in batch mode, requiring simultaneous access to all training images during the learning process, which results in very high memory usage and severely limits the training data size that can be used. Very recently, however, a number of authors have considered the design of online convolutional dictionary learning algorithms that offer far better scaling of memory and computational cost with training set size than batch methods. This study extends our prior work, improving a number of aspects of our previous algorithm; proposing an entirely new one, with better performance, that supports the inclusion of a spatial mask for learning from incomplete data; and providing a rigorous theoretical analysis of these methods.

97 MATHEMATICS AND COMPUTING↗

Data Elevator

Data Elavator allows extensive optimizations, such as overlapping read and write operations, choosing I/O modes, and aligning buffer boundaries. Is as much as 4.2X faster than Cray DataWarp, the start-of-art software for burst buffer, and 4X faster than directly writing to PFS.

Wu, Kesheng↗

MultiAlign: a multiple LC-MS analysis tool for targeted omics analysis

MultiAlign is a free software tool that aligns multiple liquid chromatography-mass spectrometry datasets to one another by clustering mass and LC elution features across datasets. Applicable to both label-free proteomics and metabolomics comparative analyses, the software can be operated in several modes. Clustered features can be matched to a reference database to identify analytes, used to generate abundance profiles, linked to tandem mass spectra based on parent precursor masses, and culled for targeted liquid chromatography-tandem mass spectrometric analysis. MultiAlign is also capable of tandem mass spectral clustering to describe proteome structure and find similarity in subsequent sample runs.

Environmental Molecular Sciences Laboratory↗