Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Production of a high brightness H{sup -} beam by charge exchange of a hydrogen atom beam in a sodium jet

Production of H{sup -} beams for applications in accelerators via charge exchange of a high brightness hydrogen neutral beam in a sodium jet cell is experimentally studied in a joint experiment by the Brookhaven National Laboratory (BNL) and the Budker Institute of Nuclear Physcis (BINP). In the experiment, a hydrogen atomic beam with an energy 3-6 keV, an equivalent current up to 5 A and a pulse duration 200 microseconds is used. Initial results demonstrate that an H{sup -} beam with a current 36 mA, an energy 5 keV and {approx}0.15 cm{center_dot}mrad normalized emittance was obtained. The recirculating sodium jet target with an entrance aperture 2 cm, which was developed for the BNL optically pumped polarized ion source, is used in the experiment. To increase the H{sup -} beam current, geometric focusing of the hydrogen neutral beam will be used in the future experiments. In addition, the effects of H{sup -} beam space-charge and sodium-jet stability will be studied to determine the basic limitations of this approach. The atomic beam is produced by charge exchange of a proton beam in a pulsed hydrogen target. The proton beam is formed by an ion source with a four-electrode multiaperture ion-optical system with small-size apertures. The plasma emission surface is formed by the plasma expansion from an arc plasma generator. The transverse ion temperature at the emission surface is 0.2 eV.

43 PARTICLE ACCELERATORS↗

Overview of the Systems Special Investigation Group investigation

The Long Duration Exposure Facility (LDEF) carried a remarkable variety of electrical, mechanical, thermal, and optical systems, subsystems, and components. Nineteen of the fifty-seven experiments flown on LDEF contained functional systems that were active on-orbit. Almost all of the other experiments possessed at least a few specific components of interest to the Systems Special Investigation Group (Systems SIG), such as adhesives, seals, fasteners, optical components, and thermal blankets. Almost all top level functional testing of the active LDEF and experiment systems has been completed. Failure analysis of both LDEF hardware and individual experiments that failed to perform as designed has also been completed. Testing of system components and experimenter hardware of interest to the Systems SIG is ongoing. All available testing and analysis results were collected and integrated by the Systems SIG. An overview of our findings is provided. An LDEF Optical Experiment Database containing information for all 29 optical related experiments is also discussed.

Mason, James B.↗

Development of ultralow energy (1–10 eV) ion scattering spectrometry coupled with reflection absorption infrared spectroscopy and temperature programmed desorption for the investigation of molecular solids

Extremely surface specific information, limited to the first atomic layer of molecular surfaces, is essential to understand the chemistry and physics in upper atmospheric and interstellar environments. Ultra low energy ion scattering in the 1–10 eV window with mass selected ions can reveal extremely surface specific information which when coupled with reflection absorption infrared (RAIR) and temperature programmed desorption (TPD) spectroscopies, diverse chemical and physical properties of molecular species at surfaces could be derived. These experiments have to be performed at cryogenic temperatures and at ultra high vacuum conditions without the possibility of collisions of neutrals and background deposition in view of the poor ion intensities and consequent need for longer exposure times. Here we combine a highly optimized low energy ion optical system designed for such studies coupled with RAIR and TPD and its initial characterization. Despite the ultralow collision energies and long ion path lengths employed, the ion intensities at 1 eV have been significant to collect a scattered ion spectrum of 1000 counts/s for mass selected CH{sub 2}{sup +}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nano-metrology: The art of measuring X-ray mirrors with slope errors <100 nrad

We present a comprehensive investigation of the systematic and random errors of the nano-metrology instruments used to characterize synchrotron X-ray optics at Diamond Light Source. With experimental skill and careful analysis, we show that these instruments used in combination are capable of measuring state-of-the-art X-ray mirrors. Examples are provided of how Diamond metrology data have helped to achieve slope errors of <100 nrad for optical systems installed on synchrotron beamlines, including: iterative correction of substrates using ion beam figuring and optimal clamping of monochromator grating blanks in their holders. Simulations demonstrate how random noise from the Diamond-NOM’s autocollimator adds into the overall measured value of the mirror’s slope error, and thus predict how many averaged scans are required to accurately characterize different grades of mirror.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial beam-profiling tests with the NML prototype station at the Fermilab A0 Photoinjector

The beam-profile diagnostics station prototype for the superconducting rf electron linac being constructed at Fermilab at the New Muon Lab has been tested. The station uses intercepting radiation converter screens for the low-power beam mode: either a 100-{micro}m thick YAG:Ce single crystal scintillator or a 1-{micro}m thin Al optical transition radiation (OTR) foil. The screens are oriented with the surface perpendicular to the beam direction. A downstream mirror with its surface at 45 degrees to the beam direction is used to direct the radiation into the optical transport. The optical system has better than 20 (10) {micro}m rms spatial resolution when covering a vertical field of view of 18 (5) mm. The initial tests were performed at the A0 Photoinjector at a beam energy of {approx}15 MeV and with micropulse charges from 25 to 500 pC for beam sizes of 45 to 250 microns. Example results will be presented.

43 PARTICLE ACCELERATORS↗

Wide-view charge exchange recombination spectroscopy diagnostic for Alcator C-Mod

This diagnostic measures temperature, density, and rotation for the fully stripped boron ion between the pedestal top and the plasma core with resolution consistent with the profile gradients. The diagnostic neutral beam used for the measurements generates a 50 keV, 6 A hydrogen beam. The optical systems provide views in both poloidal and toroidal directions. The imaging spectrometer is optimized to simultaneously accept 45 views as input with minimum cross-talk. In situ calibration techniques are applied for spatial location, spectral intensity, and wavelength. In the analysis, measured spectra are fitted to a model constructed from a detailed description of the emission physics. Methods for removal of interfering spectra are included. Applications include impurity and thermal transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron density profile measurements from hydrogen line intensity ratio method in Versatile Experimental Spherical Torus

Electron density profiles of versatile experiment spherical torus plasmas are measured by using a hydrogen line intensity ratio method. A fast-frame visible camera with appropriate bandpass filters is used to detect images of Balmer line intensities. The unique optical system makes it possible to take images of H{sub α} and H{sub β} radiation simultaneously, with only one camera. The frame rate is 1000 fps and the spatial resolution of the system is about 0.5 cm. One-dimensional local emissivity profiles have been obtained from the toroidal line of sight with viewing dumps. An initial result for the electron density profile is presented and is in reasonable agreement with values measured by a triple Langmuir probe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solving scattering problems in the half-line using methods developed for scattering in the full line

We reduce the solution of the scattering problem defined on the half-line [0,∞) by a real or complex potential v(x) and a general homogeneous boundary condition at x=0 to that of the extension of v(x) to the full line that vanishes for x<0. We find an explicit expression for the reflection amplitude of the former problem in terms of the reflection and transmission amplitudes of the latter. We obtain a set of conditions on these amplitudes under which the potential in the half-line develops bound states, spectral singularities, and time-reversed spectral singularities where the potential acts as a perfect absorber. We examine the application of these results in the study of the scattering properties of a δ-function potential and a finite barrier potential defined in [0,∞), discuss optical systems modeled by these potentials, and explore the configurations in which these systems act as a laser or perfect absorber. In particular, we derive an explicit formula for the laser threshold condition for a slab laser with a single mirror and establish the surprising fact that a nearly perfect mirror gives rise to a lower threshold gain than a perfect mirror. We also offer a nonlinear extension of our approach which allows for utilizing a recently developed nonlinear transfer matrix method in the full line to deal with finite-range nonlinear scattering interactions defined in the half-line.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development and Testing of a Post-Installable Deepwater Monitoring System Using Fiber-Optic Sensors

This paper addresses the design and development of a fiber-optic monitoring system that can be deployed on existing deepwater risers and flowlines; and provides a summary of test article fabrication and the subsequent laboratory testing performed at the National Aeronautics and Space Administration-Johnson Space Center (NASA-JSC). A major challenge of a post-installed instrumentation system is to ensure adequate coupling between the instruments and the riser or flowline of interest. This work investigates the sensor coupling for pipelines that are suspended in a water column (from topside platform to seabed) using a fiber-optic sensor clamp and subsea bonding adhesive. The study involved the design, fabrication, and test of several prototype clamps that contained fiber-optic sensors. A mold was produced by NASA using 3-D printing methods that allowed the casting of polyurethane clamp test articles to accommodate 4-inch and 8-inch diameter pipes. The prototype clamps were installed with a subsea adhesive in a "wet" environment and then tested in the NASA Structures Test Laboratory (STL). The tension, compression, and bending test data showed that the prototype sensor clamps achieved good structural coupling, and could provide high quality strain measurement for active monitoring.

Seaman, Calvin H.↗

Simulations of two-particle interactions with 2D quantum walks in time

We present the experimental implementation of a quantum walk on a two-dimensional lattice and show how to employ the optical system to simulate the quantum propagation of two interacting particles. Our quantum walk in time transfers the spatial spread of a quantum walk into the time domain, which guarantees a high stability and scalability of the setup. We present with our device quantum walks over 12 steps on a 2D lattice. By changing the properties of the driving quantum coin, we investigate different kinds of two-particle interactions and reveal their impact on the occurring quantum propagation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Imaging penetrating radiation through ion photon emission microscopy.

The ion photon emission microscope (IPEM), a new radiation effects microscope for the imaging of single event effects from penetrating radiation, is being developed at Sandia National Laboratories and implemented on the 88' cyclotron at Lawrence Berkeley National Laboratories. The microscope is designed to permit the direct correlation between the locations of high-energy heavy-ion strikes and single event effects in microelectronic devices. The development of this microscope has required the production of a robust optical system that is compatible with the ion beam lines, design and assembly of a fast single photon sensitive measurement system to provide the necessary coincidence, and the development and testing of many scintillating films. A wide range of scintillating material for application to the ion photon emission microscope has been tested with few meeting the stringent radiation hardness, intensity, and photon lifetime requirements. The initial results of these luminescence studies and the current operation of the ion photon emission microscope will be presented. Finally, the planned development for future microscopes and ion luminescence testing chambers will be discussed.

43 PARTICLE ACCELERATORS↗

X-ray Phase Imaging Microscopy using a Fresnel Zone Plate and a Transmission Grating

We report on a hard X-ray phase imaging microscopy (a phase-difference microscopy) that consists of an objective and a transmission grating. The simple optical system provides a quantitative phase image, and does not need a wave field mostly coherent on the objective. Our method has a spatial resolution almost same as that of the absorption contrast microscope image obtained by removing the grating. We demonstrate how our approach provides a phase image from experimentally obtained images. Our approach is attractive for easily appending a quantitative phase-sensitive mode to normal X-ray microscopes, and has potentially broad applications in biology and material sciences.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Mass separation of a multicomponent plasma flow in a curvilinear magnetic field

The motion of a metal plasma flow of a vacuum-arc discharge in a transportation plasma-optical system with a curvilinear magnetic field is studied experimentally and numerically. The flow position at the output of the system is shown to depend on the cathode material, which determines the mass-to-charge ratio of plasma ions. As a result, the flow with a greater ion mass-to-charge ratio moves along a trajectory with a larger radius. A similar effect is observed in the case of a multicomponent plasma flow generated by a composite cathode. The results of two-fluid MHD simulations of a plasma flow propagating in a curvilinear magnetic field agree qualitatively with the experimental data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Production, formation, and transport of high-brightness atomic hydrogen beam studies for the relativistic heavy ion collider polarized source upgrade

The RHIC polarized H{sup −} ion source had been successfully upgraded to higher intensity and polarization by using a very high brightness fast atomic beam source developed at BINP, Novosibirsk. In this source the proton beam is extracted by a four-grid multi-aperture ion optical system and neutralized in the H{sub 2} gas cell downstream from the grids. The proton beam is extracted from plasma emitter with a low transverse ion temperature of ∼0.2 eV which is formed by plasma jet expansion from the arc plasma generator. The multi-hole grids are spherically shaped to produce “geometrical” beam focusing. Proton beam formation and transport of atomic beam were experimentally studied at test bench.

43 PARTICLE ACCELERATORS↗

GTC/OSIRIS SPECTROSCOPIC IDENTIFICATION OF A FAINT L SUBDWARF IN THE UKIRT INFRARED DEEP SKY SURVEY

We present the discovery of an L subdwarf in 234 deg{sup 2} common to the UK InfraRed Telescope (UKIRT) Infrared Deep Sky Survey Large Area Survey Data Release 2 and the Sloan Digital Sky Survey Data Release 3. This is the fifth L subdwarf announced to date, the first one identified in the UKIRT Infrared Deep Sky Survey, and the faintest known. The blue optical and near-infrared colors of ULAS J135058.86+081506.8 and its overall spectra energy distribution are similar to the known mid-L subdwarfs. Low-resolution optical (700-1000 nm) spectroscopy with the Optical System for Imaging and low Resolution Integrated Spectroscopy spectrograph on the 10.4 m Gran Telescopio de Canarias reveals that ULAS J135058.86+081506.8 exhibits a strong K I pressure-broadened line at 770 nm and a red slope longward of 800 nm, features characteristics of L-type dwarfs. From direct comparison with the four known L subdwarfs, we estimate its spectral type to be sdL4-sdL6 and derive a distance in the interval 94-170 pc. We provide a rough estimate of the space density for mid-L subdwarfs of 1.5 x 10{sup -4} pc{sup -3}.

79 ASTRONOMY AND ASTROPHYSICS↗

Reduce, reuse, recycle for robust cluster-state generation

Efficient generation of cluster states is crucial for engineering large-scale measurement-based quantum computers. Hybrid matter-optical systems offer a robust, scalable path to this goal. Such systems have an ancilla which acts as a bus connecting the qubits. We show that by generating the cluster in smaller sections of interlocking bricks, reusing one ancilla per brick, the cluster can be produced with maximal efficiency, requiring fewer than half the operations compared with no bus reuse. By reducing the time required to prepare sections of the cluster, bus reuse more than doubles the size of the computational workspace that can be used before decoherence effects dominate. A row of buses in parallel provides fully scalable cluster-state generation requiring only 20 controlled-phase gates per bus use.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Extending the path for efficient extreme ultraviolet sources for advanced nanolithography

Developing efficient light sources for extreme ultraviolet (EUV) lithography is one of the most important problems of high volume manufacturing (HVM) of the next generation computer chips. Critical components of this technology are continued to face challenges in the demanding performance for HVM. Current investigations of EUV and beyond EUV (BEUV) community are focused on the dual-pulse laser produced plasma (LPP) using droplets of mass-limited targets. Two main objectives as well as challenges in the optimization of these light sources are related to enhancement of the conversion efficiency (CE) of the source and increase components lifetime of the collector optical system. These require significant experimental and computer simulation efforts. These requirements call for fine detail analysis of various plasma physics processes involved in laser target interactions and their effects on source optimization. We continued to enhance our comprehensive HEIGHTS simulation package and upgrade our CMUXE laboratories to study and optimize the efficiency of LPP sources. Integrated modeling and experimental research were done to both benchmark simulation results and to make projections and realistic predictions of the development path for powerful EUVL devices for HVM requirements. We continued the detail analysis of dual-pulse laser systems using various laser wavelengths and delay times between the two pulses. We showed that the efficiency of EUV sources can be improved utilizing the higher harmonics of Nd:YAG laser for the prepulse and the first harmonics for the main pulse, while still having lower efficiency than the combination involving CO{sub 2} laser in the range of parameters studied in this case. The differences in optimization process as well as in the source characteristics for two combinations of laser wavelengths were analyzed based on details of atomic and hydrodynamics processes during the evolving plasma plumes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnostic developments for quasicontinuous operation of the Wendelstein 7-X stellarator

The stellarator Wendelstein 7-X will allow for quasicontinuous operation with the duration only being limited to two 30 min discharges per day, at a continuous heating power of 10 MW electron cyclotron resonance heating (ECRH) at 140 GHz, by the capacity of the cooling water reservoir. This will result in high thermal loads on all plasma facing components of 50-100 kW/m{sup 2} from radiation alone and of up to about 500 kW/m{sup 2} on components additionally exposed to convective loads. In high density scenarios toroidally varying ECRH stray radiation levels of 50-200 kW/m{sup 2} need to be coped with, requiring careful material selection and different shielding and hardening techniques. Furthermore, a gradual buildup of coatings on plasma facing optical components, which without any measures being taken, would lead to high transmission losses already within a few days of long pulse operation (equivalent to about 1 year of operation in pulsed devices like JET or ASDEX-upgrade) and therefore needs to be prevented as much as possible. In addition in situ cleaning as well as absolute calibration techniques need to be developed for all plasma facing optical systems. Here we report about some of our efforts to find, for various types of diagnostics, ways to cope with these adverse effects. Moreover, we give a few examples for individual diagnostic specific issues with respect to quasicontinuous operation, such as the development of a special integrator for the magnetic diagnostics as well as special interferometer types which can cope with unavoidable vibrations and slow path length changes due to, e.g., thermal expansion of the plasma vessel.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗