Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical signal processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Precision of FLEET Velocimetry Using High-speed CMOS Camera Systems

Femtosecond laser electronic excitation tagging (FLEET) is an optical measurement technique that permits quantitative velocimetry of unseeded air or nitrogen using a single laser and a single camera. In this paper, we seek to determine the fundamental precision of the FLEET technique using high-speed complementary metal-oxide semiconductor (CMOS) cameras. Also, we compare the performance of several different high-speed CMOS camera systems for acquiring FLEET velocimetry data in air and nitrogen free-jet flows. The precision was defined as the standard deviation of a set of several hundred single-shot velocity measurements. Methods of enhancing the precision of the measurement were explored such as digital binning (similar in concept to on-sensor binning, but done in post-processing), row-wise digital binning of the signal in adjacent pixels and increasing the time delay between successive exposures. These techniques generally improved precision; however, binning provided the greatest improvement to the un-intensified camera systems which had low signal-to-noise ratio. When binning row-wise by 8 pixels (about the thickness of the tagged region) and using an inter-frame delay of 65 micro sec, precisions of 0.5 m/s in air and 0.2 m/s in nitrogen were achieved. The camera comparison included a pco.dimax HD, a LaVision Imager scientific CMOS (sCMOS) and a Photron FASTCAM SA-X2, along with a two-stage LaVision High Speed IRO intensifier. Excluding the LaVision Imager sCMOS, the cameras were tested with and without intensification and with both short and long inter-frame delays. Use of intensification and longer inter-frame delay generally improved precision. Overall, the Photron FASTCAM SA-X2 exhibited the best performance in terms of greatest precision and highest signal-to-noise ratio primarily because it had the largest pixels.

Peters, Christopher J.↗

Radar Measurements of the LEO Orbital Debris Environment

Access to space and the preservation of the near-Earth space environment is of critical significance. Increased interest in issues surrounding space traffic management and the continued assessment and discussion of orbital debris at the United Nations Committee on the Peaceful Uses of Outer Space (COPUOS) illustrates the significance of the topic of orbital debris. There are currently over 20,000 tracked objects in the publicly available satellite catalog on Space-Track.org. The catalog is maintained by the US Air Force Space Command using a network of optical and radar ground-based sensors and is believed to be complete for a characteristic size of 10 cm or larger in low Earth orbit (LEO). Based on the work of the NASA Orbital Debris Program Office (ODPO) over approximately the past 40 years it is understood that the small debris population (< 10 cm) increases by orders of magnitude as characteristic size decreases. With population estimates ranging from 500,000 to 1,000,000 small debris objects (> 5 mm) in orbit, it is currently not practical to track and maintain precision orbits on every object. Instead the NASA ODPO uses powerful ground-based radars to sample the low Earth Orbit (LEO) environment and assign approximate orbits to each detection. This poses an interesting signal processing challenge as we are trying to detect the smallest objects possible on the edge of the radar's sensitivity. For approximately the last 30 years, NASA ODPO has partnered with the Massachusetts Institute of Technology Lincoln Laboratory (MIT/LL) to utilize the Haystack Ultra-wideband Satellite Imaging Radar (HUSIR - formerly the Long-Range Imaging Radar or simply Haystack) and the Haystack Auxiliary (HAX) radar to collect orbital debris radar data. Additionally, the ODPO collaborates with the NASA Jet Propulsion Laboratory (JPL) to use the Goldstone Solar System Radar. The orbital debris detections from these radars serve as inputs for statistical risk models used by the human spaceflight and satellite communities to assess risk to spacecraft posed by orbital debris. In this paper, we will describe the history of orbital debris radar measurements conducted by NASA, provide an overview of current radar measurements techniques and facilities, discuss the signal processing software used for orbital debris measurements and the inference of debris size and orbital parameters from these measurements, and discuss how orbital debris radar measurements are validated for use in models that are used throughout the aerospace industry.

Blackwell, Chris↗

Side chain dynamics in semiconducting polymer MEH-PPV

We report that the characteristic nanoscale dynamics of the alkyl side groups in the light-emitting polymer poly[2-methoxy-5-(2'-ethyl-hexyloxy)-1,4-phenylene vinylene] have been investigated using quasi-elastic neutron scattering (QENS). The measurements were taken below the polymer's glass transition (T ≤ T g ≃ 353 K), where the main backbone is in a rigid state and does not contribute to the broadening of the QENS signal. An analytical diffusion model consisting of a static term and two dynamical components, characterizing the flexible side groups, provide an excellent fit to the experimental data. The two observed dynamical processes are all localized in character, with no meaningful dependence on temperature. The faster process, with characteristic timescale of ~18 ps at room temperature (RT), can be linked to the average mobility of the terminal protons of the alkyl chain, while the slower process, with characteristic timescale of ~170 ps at RT, to those protons at the other end of the alkyl chain, closest to the backbone. Lastlyl, while the fraction of mobile protons contributing to the QENS signal increases with increasing temperature, the characteristic timescale and confining volume within which the protons are able to move locally depend chiefly on the polymer conformational state.

36 MATERIALS SCIENCE↗

Automated mass spectrometer analysis system

An automated mass spectrometer analysis system is disclosed, in which samples are automatically processed in a sample processor and converted into volatilizable samples, or their characteristic volatilizable derivatives. Each volatilizable sample is sequentially volatilized and analyzed in a double focusing mass spectrometer, whose output is in the form of separate ion beams all of which are simultaneously focused in a focal plane. Each ion beam is indicative of a different sample component or different fragments of one or more sample components and the beam intensity is related to the relative abundance of the sample component. The system includes an electro-optical ion detector which automatically and simultaneously converts the ion beams, first into electron beams which in turn produce a related image which is transferred to the target of a vilicon unit. The latter converts the images into electrical signals which are supplied to a data processor, whose output is a list of the components of the analyzed sample and their abundances. The system is under the control of a master control unit, which in addition to monitoring and controlling various power sources, controls the automatic operation of the system under expected and some unexpected conditions and further protects various critical parts of the system from damage due to particularly abnormal conditions.

Kuppermann, Aron↗

Automated mass spectrometer analysis system

An automated mass spectrometer analysis system is disclosed, in which samples are automatically processed in a sample processor and converted into volatilizable samples, or their characteristic volatilizable derivatives. Each volatizable sample is sequentially volatilized and analyzed in a double focusing mass spectrometer, whose output is in the form of separate ion beams all of which are simultaneously focused in a focal plane. Each ion beam is indicative of a different sample component or different fragments of one or more sample components and the beam intensity is related to the relative abundance of the sample component. The system includes an electro-optical ion detector which automatically and simultaneously converts the ion beams, first into electron beams which in turn produce a related image which is transferred to the target of a vidicon unit. The latter converts the images into electrical signals which are supplied to a data processor, whose output is a list of the components of the analyzed sample and their abundances. The system is under the control of a master control unit, which in addition to monitoring and controlling various power sources, controls the automatic operation of the system under expected and some unexpected conditions and further protects various critical parts of the system from damage due to particularly abnormal conditions.

Boettger, Heinz G.↗

Simulation of an intracavity Q -switched optical parametric oscillator using rate equations

Based on rate equations we have refined the model of an intracavity Q -switched optical parametric oscillator (IOPO) by taking into account the influence of self-Raman stimulated scattering. The rate equations are solved and analysed in the plane-wave approximation for a Gaussian spatial beam distribution profile under various conditions. The spatial rate equations are also solved numerically for a beam with a field distribution of the TEM{sub 00} mode. The numerical analysis shows that stimulated self-Raman scattering leads to a decrease in the output signal power and an increase in the signal pulse width. This model allows one to predict that the output signal power can be increased with increasing ratio of Raman to fundamental photon lifetimes. This suggests a practical method for determining the self-Raman gain coefficient experimentally. In addition, a multi-pulse process for the signal beam of the IOPO can be regenerated by the presented model. However, in comparison with the previous research, the presented model is more accurate and allows one to design and optimise single-resonator IOPOs.The bibliography includes 25 references. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Geophysical Signatures of Crack Network Coalescence in Rocks at Multiple Length Scales

The main goal of the research project was to identify the geophysical signatures of fracture growth in natural rocks by utilizing novel geophysical techniques. The research objectives were to (a) investigate the potential for geophysical methods to determine when cracks initiate, the types and locations of propagated cracks, and the coalescence of networks of cracks in natural rocks at multiple scales, (b) determine how damage at the microscale evolved into damage at the macroscale and then link the microscopic and macroscopic observations, (c) quantify crack coalescence in rocks under realistic stress conditions using coupled mechanical-geophysical-optical visualization, and (d) identify the precursors in geophysical signals to crack coalescence. The following research thrusts were explored to achieve the research objectives: (1) uniaxial compression testing of rock specimens with and without a set of pre‐existing flaws and (2) triaxial compression testing of natural rock specimens. These thrusts allowed for exploring fracturing in rocks under realistic in situ environments and at multiple scales. This project provided educational opportunities for nine graduate and undergraduate students and resulted in 27 peer-reviewed publications. This first research thrust focused on investigating the micromechanics of fractures in rocks through uniaxial compression testing combined with advanced geophysical and imaging techniques, specifically acoustic emission (AE) monitoring, ultrasonic imaging, and 2-dimensional Digital Image Correlation (2D-DIC). By examining damage processes under time-independent and time-dependent loading conditions, insights into damage localization, crack initiation, and fracturing mechanisms were gained. It was observed that the AE signals and the strain-based measurements directly reflect the state of damage in the rock specimen and could be used to identify the cracking levels, such as the crack initiation (CI) and crack damage (CD), and the mode of deformation. A novel calibration apparatus was developed to enhance the accuracy of AE sensors, allowing for the estimation of key parameters such as magnitude, source dimension, stress drop, and radiated seismic energy associated with the fractures. The findings highlighted significant variations in the temporal evolution of AE source parameters during the primary, secondary, and tertiary stages of creep, identifying tensile cracking as the primary deformation mode. The second research thrust focused on enhancing the understanding of fracturing processes in natural rocks through triaxial compression testing, real-time AE monitoring, and ultrasonic monitoring. We investigated the impact of various factors such as fracture propagation regimes, injection parameters, rock types, and pre-existing conditions on the hydraulic fracture (HF) behavior using scaled true-triaxially loaded specimens of Barre granite and Lyons sandstone. Custom sensor housing facilitated concurrent active and passive monitoring to analyze hydro-mechanical responses and microseismicity associated with different HF scenarios. A coupled investigation of passive microseismicity and active signal attributes permitted a detailed comprehension of the various HF processes (aseismic deformation, fracture initiation and propagation, fluid permeation, and leak-off) and their dependence on the specific rock type. The findings of this research demonstrated the effectiveness of AE monitoring techniques in providing valuable insights into the impact of various factors on the behavior and dynamics of HF processes. The advancements in monitoring techniques, offering a more thorough and precise approach, represent a significant step towards optimizing HF practices and ensuring sustainable resource extraction.

58 GEOSCIENCES↗

Optical diagnostics of solution crystal growth

Solution crystal growth monitoring of LAP/TGS crystals by various optical diagnostics systems, such as conventional and Mach-Zehnder (M-Z) interferometers, optical heterodyne technique, and ellipsometry, is under development. The study of the dynamics of the crystal growth process requires a detailed knowledge of crystal growth rate and the concentration gradient near growing crystals in aqueous solution. Crystal growth rate can be measured using conventional interferometry. Laser beam reflections from the crystal front as well as the back surface interfere with each other, and the fringe shift due to the growing crystal yields information about the growth rate. Our preliminary results indicate a growth rate of 6 A/sec for LAP crystals grown from solution. Single wavelength M-Z interferometry is in use to calculate the concentration gradient near the crystal. Preliminary investigation is in progress using an M-Z interferometer with 2 cm beam diameter to cover the front region of the growing crystal. In the optical heterodyne technique, phase difference between two rf signals (250 KHZ) is measured of which one is a reference signal, and the other growth signal, whose phase changes due to a change in path length as the material grows. From the phase difference the growth rate can also be calculated. Our preliminary results indicate a growth rate of 1.5 A/sec. the seed and solution temperatures were 26.46 C and 27.92 C respectively, and the solution was saturated at 29.0 C. an ellipsometer to measure the growth rate and interface layer is on order from JOBIN YVON, France. All these systems are arranged in such a manner that measurements can be made either sequentially or simultaneously. These techniques will be adapted for flight experiment.

Kim, Yongkee↗

NASA Tech Briefs, July 2004

Topics: Optoelectronic Sensor System for Guidance in Docking; Hybrid Piezoelectric/Fiber-Optic Sensor Sheets; Multisensor Arrays for Greater Reliability and Accuracy; Integrated-Optic Oxygen Sensors; Ka-Band Autonomous Formation Flying Sensor; CMOS VLSI Active-Pixel Sensor for Tracking; Lightweight, Self-Deploying Foam Antenna Structures; Electrically Small Microstrip Quarter-Wave Monopole Antennas; A 2-to-28-MHz Phase-Locked Loop; Portable Electromyograph; Open-Source Software for Modeling of Nanoelectronic Devices; Software for Generating Strip Maps from SAR Data; Calibration Software for use with Jurassicprok; Software for Probabilistic Risk Reduction; Software Processes SAR Motion-Measurement Data; Improved Method of Purifying Carbon Nanotubes; Patterned Growth of Carbon Nanotubes or Nanofibers; Lightweight, Rack-Mountable Composite Cold Plate/Shelves; SiC-Based Miniature High-Temperature Cantilever Anemometer; Inlet Housing for a Partial-Admission Turbine; Lightweight Thermoformed Structural Components and Optics; Growing High-Quality InAs Quantum Dots for Infrared Lasers; Selected Papers on Protoplanetary Disks; Module for Oxygenating Water without Generating Bubbles; Coastal Research Imaging Spectrometer; Rapid Switching and Modulation by use of Coupled VCSELs; Laser-Induced-Fluorescence Photogrammetry and Videogrammetry; Laboratory Apparatus Generates Dual-Species Cold Atomic Beam; Laser Ablation of Materials for Propulsion of Spacecraft; Small Active Radiation Monitor; Hybrid Image-Plane/Stereo Manipulation; Partitioning a Gridded Rectangle into Smaller Rectangles; Digital Radar-Signal Processors Implemented in FPGAs; Part 1 of a Computational Study of a Drop-Laden Mixing Layer; and Some Improvements in Signal-Conditioning Circuits.

Source record↗

Multiplexing of Hot-Electron Nanobolometers Using Microwave SQUIDs

We have obtained the first data on the multiplexed operation of titanium hot-electron bolometers (HEB). Because of their low thermal conductance and small electron heat capacity nanobolometers are particularly interesting as sensors for far-infrared spectroscopy and mid- and near-IR calorimetry. However, the short time constant of these devices (approximately microseconds at 300-400 mK) makes time domain or audio-frequency domain multiplexing impractical. The Microwave SQUID (MSQUID) approach pursued in this work uses dc SQUIDs coupled to X-band microresonators which are, in turn, coupled to a transmission line. We used a 4-element array of Ti HEBs operated at 415 mK in a He3 dewar with an optical fiber access. The microwave signal exhibited 10-MHz wide resonances at individual MSQUD frequencies between 9 GHz and 10 GHz. The resonance depth is modulated by the current through the bolometer via a change of the SQUID flux state. The transmitted signal was amplified by a cryogenic amplifier and downconverted to baseband using an IQ mixer. A 1-dB per ??/2 responsivity was sufficient for keeping the system noise at the level of ~ 2 pA/Hz1/2. This is more than an order of magnitude smaller than phonon noise in the HEB. The devices were able to detect single near- IR photons (1550 nm) with a time constant of 3.5 ?s. Follow-on work will scale the array to larger size and will address the microwave frequency signal generation and processing using a digital transceiver.

microwave readout↗

Towards a program of record of inland water quality: Exploiting present and heritage multispectral sensors for maximum information extraction

Degradation of Earth’s inland water resources due to anthropogenic perturbations and climate anomalies at both local and global scales continues to place human health at substantial risk. There is now a growing necessity to develop pragmatic approaches that allow timely and effective extrapolation of local processes, to spatially resolved global products, and to promote operational and sustainable resource policy management. This research exploits recent advancements in bio-optical modeling, cloud computing, and machine learning to enhance our capacity to leverage present and heritage satellite data. Recent research suggests that sensors with low spectral resolution, such as Sentinel 2 and Landsat missions, contain enough hidden spectral variation which can be exploited using data-driven approaches. The availability of three decades of archival imagery will open doors to discover global trends of eutrophication and increased cyanobacteria dominance and provide valuable insight to the development of predictive methodologies. Preliminary efforts in synthetic emulation of global natural inland waters will be discussed and contextualized against satellite radiometric measurement uncertainty, satellite data product uncertainties and causal signal ambiguity over the visible wavelength range, supported by high quality field and image data for selected inland aquatic sites. Insights on water quality estimation via data-driven machine learning models versus matrix inversions will be discussed, and how we can exploit spectral-spatial relationships in high spatial resolution data. A cross-sensor synergistic approach with detailed uncertainty analysis based on optical water types, will allow for unprecedented global snapshots of fine scale ecological dynamics of inland waters.

Inland↗

Experimental demonstration of higher-order Laguerre-Gauss mode interferometry

The compatibility of higher-order Laguerre-Gauss (LG) modes with interferometric technologies commonly used in gravitational wave detectors is investigated. In this paper, we present the first experimental results concerning the performance of the LG{sub 33} mode in optical resonators. We show that the Pound-Drever-Hall error signal for a LG{sub 33} mode in a linear optical resonator is identical to that of the more commonly used LG{sub 00} mode, and demonstrate the feedback control of the resonator with a LG{sub 33} mode. We succeeded to increase the mode purity of a LG{sub 33} mode generated using a spatial-light modulator from 51% to 99% upon transmission through a linear optical resonator. We further report the experimental verification that a triangular optical resonator does not transmit helical LG modes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pre-Ionization Controlled Laser Plasma Formation for Ignition Applications (Final Scientific/Technical Report)

This report consists of three grand funded papers. Abstracts for each follow. 1) In this work, we present experimental and modeling studies of air pre-ionization using ultraviolet (UV) laser pulses and its effect on laser breakdown of an overlapped near-infrared (NIR) pulse. Experimental studies are conducted with a 266 nm beam (fourth harmonic of Nd:YAG) for UV pre-ionization and an overlapped 1064 nm NIR beam (fundamental of Nd:YAG), both having pulse duration of 10 ns. Results show that the UV beam produces a pre-ionized volume which assists in breakdown of the NIR beam, leading to reduction in NIR breakdown threshold by factor of >2. Numerical modeling is performed to examine the ionization and breakdown of both beams. The modeled breakdown threshold of the NIR, including assist by pre-ionization, is in reasonable agreement with the experimental results. 2) The present contribution compares the energy absorption, optical emission, temperature, and fluid dynamics of ultraviolet (UV) λ = 266 nm and near infrared (NIR) λ = 1064 nm nanosecond laser induced plasmas in ambient air. For UV pulses at the conditions studied, energy absorption by the plasmas increases relatively gradually with laser pulse energy starting at delivered energy of E~8 mJ. Corresponding measurements of plasma luminosity show that the absorption of UV radiation does not necessarily result in visible plasma emission. For the NIR induced plasmas, the energy absorption profile is far more abrupt and begins at ~55 mJ. In contrast with UV, the absorption of NIR radiation is always accompanied by intense optical emission. The temperatures of both types of plasma have been measured with Rayleigh scattering thermometry (at times after the Thomson signal sufficiently diminishes). The UV plasmas can attain a wider range of temperatures, including lower temperatures, depending on the pulse energy (e.g., T ~400–2000K for E ~7–35 mJ at Δt = 10 μs after the pulse) while the NIR plasmas show only hotter temperatures (e.g., T ~ 12 000 K for E = 75 mJ at Δt = 10 μs after the pulse) as is consistent with the literature. Differences in the fluid dynamics for UV versus NIR pulses are shown with Schlieren imaging. In this work, the contrast in the UV and NIR plasma threshold behavior is attributed to differing roles of avalanche ionization and multiphoton ionization as is also illustrated by a simple numerical model. 3) The present contribution examines the impact of plasma dynamics and plasma-driven fluid dynamics on the flame growth of laser ignited mixtures and shows that a new dual-pulse scheme can be used to control the kernel formation process in ways that extend the lean ignition limit. We perform a comparative study between (conventional) single-pulse laser ignition (λ = 1064 nm) and a novel dual-pulse method based on combining an ultraviolet (UV) pre-ionization pulse (λ = 266 nm) with an overlapped near-infrared (NIR) energy addition pulse (λ = 1064 nm). We employ OH* chemiluminescence to visualize the evolution of the early flame kernel. For single-pulse laser ignition at lean conditions, the flame kernel separates through third lobe detachment, corresponding to high strain rates that extinguish the flame. In this work, we investigate the capabilities of the dual-pulse to control the plasma-driven fluid dynamics by adjusting the axial offset of the two focal points. In particular, we find there exists a beam waist offset whereby the resulting vorticity suppresses formation of the third lobe, consequently reducing flame stretch. With this approach, we demonstrate that the dual-pulse method enables reduced flame speeds (at early times), an extended lean limit, increased combustion efficiency, and decreased laser energy requirements.

Mechanical engineering↗

Fast, high-fidelity, all-optical and dynamically-controlled polarization gate using room-temperature atomic vapor

We demonstrate a fast, all-optical polarization gate in a room-temperature atomic medium. Using a Polarization-Selective-Kerr-Phase-Shift (PSKPS) technique, we selectively write a π phase shift to one circularly-polarized component of a linearly-polarized input signal field. The output signal field maintains its original strength but acquires a 90° linear polarization rotation, demonstrating fast, high-fidelity, dynamically-controlled polarization gate operation. The intensity of the polarization-switching field used in this PKSPK-based polarization gate operation is only 2 mW/cm{sup 2}, which would be equivalent to 0.5 nW of light power (λ = 800 nm) confined in a typical commercial photonic hollow-core fiber. This development opens a realm of possibilities for potential future extremely low light level telecommunication and information processing systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Autonomous sputter synthesis of thin film nitrides with composition controlled by Bayesian optimization of optical plasma emission

Autonomous experimentation has emerged as an efficient approach to accelerate the pace of material discovery. Although instruments for autonomous synthesis have become popular in molecular and polymer science, solution processing of hybrid materials, and nanoparticles, examples of autonomous tools for physical vapor deposition are scarce yet important for the semiconductor industry. Here, we report the design and implementation of an autonomous workflow for sputter deposition of thin films with controlled composition, leveraging a highly automated sputtering reactor custom-controlled by Python, optical emission spectroscopy (OES), and a Bayesian optimization algorithm. We modeled film composition, measured by x-ray fluorescence, as a linear function of plasma emission lines monitored during co-sputtering from elemental Zn and Ti targets in an N 2 and Ar atmosphere. A Bayesian control algorithm, informed by OES, navigates the space of sputtering power to fabricate films with user-defined compositions by minimizing the absolute error between desired and measured optical emission signals. We validated our approach by autonomously fabricating Zn x Ti 1-x N y films that deviate from the targeted cation composition by a relative ±3.5%, even for 15 nm thin films, demonstrating that the proposed approach can reliably synthesize thin films with a specific composition and minimal human interference. Moreover, the proposed method can be extended to more difficult synthesis experiments where plasma intensity lines depend non-linearly on pressure, or the elemental sticking coefficients strongly depend on the substrate temperature.

36 MATERIALS SCIENCE↗

An investigation of self-subtraction holography in LiNbO3

A sample having self subtraction characteristics that were very promising was tested in depth: hologram formation times were on the order of 150 sec, the null signal was less than 2.5% of the peak signal, and no fatigue nor instability was detected over the span of the experiments. Another sample, fabricated with, at most, slight modifications did not perform nearly as well. In all samples, attempts to improve self subtraction characteristics by various thermal treatments had no effects or adverse effects, with one exception in which improvement was noted after a time delay of several days. A theory developed to describe self subtraction showed the observed decrease in beam intensity with time, but the shape of the predicted decay curve was oscillatory in contrast to the exponential like decay observed. The theory was also inadequate to account for the experimental sensitivity of self subtraction to the Bragg angle of the hologram. It is concluded that self subtraction is a viable method for optical processing systems requiring background discrimination.

Vahey, D. W.↗

Nonlinear reflection of a spherically divergent N-wave from a plane surface: Optical interferometry measurements in air

Mach stem is a well-known structure typically observed in the process of strong (acoustic Mach numbers greater than 0.4) step-shock waves reflection from a rigid boundary. However, this phenomenon has been much less studied for weak shocks in nonlinear acoustic fields where Mach numbers are in the range from 0.001 to 0.01 and pressure waveforms have more complicated waveforms than step shocks. The goal of this work was to demonstrate experimentally how nonlinear reflection occurs in air for very weak spherically divergent acoustic spark-generated pulses resembling an N-wave. Measurements of reflection patterns were performed using a Mach-Zehnder interferometer. A thin laser beam with sub-millimeter cross-section was used to obtain the time resolution of 0.4 µs, which is 6 times higher than the time resolution of the condenser microphones. Pressure waveforms were reconstructed using the inverse Abel transform applied to the phase of the signal measured by the interferometer. The Mach stem formation was observed experimentally as a result of collision of the incident and reflected shock pulses. It was shown that irregular reflection of the pulse occurred in a dynamic way and the length of the Mach stem increased linearly while the pulse propagated along the surface. Since the front shock of the spark-generated pulse was steeper than the rear shock, irregular type of reflection was observed only for the front shock of the pulse while the rear shock reflection occurred in a regular regime.

42 ENGINEERING↗

Applications of Phase-Based Motion Processing

Image pyramids provide useful information in determining structural response at low cost using commercially available cameras. The current effort applies previous work on the complex steerable pyramid to analyze and identify imperceptible linear motions in video. Instead of implicitly computing motion spectra through phase analysis of the complex steerable pyramid and magnifying the associated motions, instead present a visual technique and the necessary software to display the phase changes of high frequency signals within video. The present technique quickly identifies regions of largest motion within a video with a single phase visualization and without the artifacts of motion magnification, but requires use of the computationally intensive Fourier transform. While Riesz pyramids present an alternative to the computationally intensive complex steerable pyramid for motion magnification, the Riesz formulation contains significant noise, and motion magnification still presents large amounts of data that cannot be quickly assessed by the human eye. Thus, user-friendly software is presented for quickly identifying structural response through optical flow and phase visualization in both Python and MATLAB.

Branch, Nicholas A.↗