Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Characterization of plutonium activities in soil - 15429

Plutonium (Pu) contamination in soils at the Nevada National Security Site (NNSS) is characterized using Am-241 activity results from gamma spectroscopy (gamma Am-241) analysis. This is done by inferring the Pu activities using Pu to Am-241 ratios developed from Pu and Am-241 results from alpha spectroscopy isotopic analyses (isotopic Pu and isotopic Am-241). Although the isotopic Pu and Am-241 methods can accurately measure isotopic activities within the sampled material, the amount of soil analyzed is small (typically 1 gram [g] of soil). If there is heterogeneity of particle distribution within the contaminated release site soil, isotopic methods may provide results that are not representative of the contaminated site. The degree of potential heterogeneity needs to be considered before using isotopic analyses to characterize a Pu-contaminated site. Results from various Pu-contaminated sites at the NNSS are presented that demonstrate significant heterogeneity. A larger sample size (∼1,600 g) within a Marinelli container is used for the gamma spectroscopy analysis. This greatly reduces the impact of heterogeneously distributed discrete particles and provides results that are more representative of true contaminant activities at the release site. However, this method cannot provide Pu activities and has the potential to provide less accurate results due to the haphazard location of contaminant particles within the Marinelli container at the time of measurement. The distance of particles from the detector would result in some differential self-absorption of the emissions from radioactive particles. As the magnitude of this problem was not previously understood, a study was conducted to evaluate the variability in Am-241 results due to self-absorption from particle position. Results from this study are shown that demonstrate that this effect provides minimal variability in replicate Am-241 measurements. The method used at the NNSS to characterize Pu activities in soil takes advantage of the accuracy of the alpha spectroscopy isotopic analyses to establish Pu to Am-241 ratios and the more representative gamma spectroscopy results for Am-241 to provide a reliable characterization of Pu activities at contaminant release sites. (authors)

54 ENVIRONMENTAL SCIENCES↗

Uranium particle age dating, aggregation, and model age best estimators

We present important aspects of uranium particle age dating by Large-Geometry Secondary Ion Mass Spectrometry (LG-SIMS) that can introduce bias and increase model age uncertainties, especially for small, young, and/or low-enriched particles. This metrology is important for applications related to International Nuclear Safeguards. We explore influential factors related to model age estimation, including the effects of evolving surface chemistry on inter-element measurements of particles (e.g., Th and U), detector background, and aggregation methods using simulated and actual particle samples. We introduce a new model age estimator, called “mid68”, that supplements 95% confidence intervals, providing a “best estimate” and uncertainty about the most likely age. The mid68 estimator can be calculated using the Feldman and Cousins method or Bayesian methods and provides a value with a symmetric uncertainty that can be used for calculations and approximate aggregation of processed model age values when the raw data and correction factors are not available. For particles yielding low 230 Th counts amidst nonzero detector background, their underlying model age probability distributions are asymmetric, so the mid68 estimator provides additional robust information regarding the underlying model age likelihood. This study provides a comprehensive and timely examination of critical aspects of uranium particle age dating as more laboratories establish particle chronometry capabilities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Alpha particle response study of polycrstalline diamond radiation detector

Chemical vapor deposition has opened the possibility to grow high purity synthetic diamond at relatively low cost. This has opened up uses of diamond based detectors for wide range of applications. These detectors are most suitable for harsh environments where standard semiconductor detectors cannot work. In this paper, we present the fabrication details and performance study of polycrystalline diamond based radiation detector. Effect of different operating parameters such as bias voltage and shaping time for charge collection on the performance of detector has been studied.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterizing complex impedance in TES Detectors for SuperCDMS

Dark Matter composes 70% of all matter in the universe and traces out the large-structure of the universe. The SuperCDMS detector attempts to directly detect thermal relic dark matter, probing down to 300MeV through nucleus scattering and 500keV through electron scattering. To accomplish this we make use of Transition Edge Sensors (TES). TES-based detectors sit in the transition regime between acting as a superconductor or a normal conductor. As particles hit the detector, they heat it changing the impedance. To characterize this process we measure the impedance at multiple DC bias points (Figure 3) and multiple temperatures (Figures 5, 6).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Engineering challenges for detectors at the ILC

Over the last years two proposals for experiments at the ILC have been developed, ILD and SID. Extensive R&D has been carried out around the world to develop the needed technologies. Furthermore a first round of engineering studies was made as part of the ILC TDR to understand the integration of these different sub-systems into coherent and integrated detector concepts. Among the key challenges for the sub detectors are the extreme low mass/low power requirements or the extreme channel densities needed in particle flow based detectors. Throughout these studies special care was taken to ensure that the engineering models and the simulation models, used in studies of the physics capabilities of the detectors, stay synchronized. In the near future, the models will need to be evolved to take the special requirements of the potential ILC site in Japan into account. Furthermore, the state of the integration of the detectors, and the future directions, will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Research in particles and fields

The astrophysical aspects of cosmic radiation and the radiation and electromagnetic field environment of the Earth and other planets are investigated. Energetic particle and photon detector systems flown on spacecraft and balloons are used. Galactic, solar, interplanetary, and planetary energetic particles and plasmas are also studied with emphasis on precision measurements with high resolution in charge, mass, and energy.

Vogt, R. E.↗

Multiple-Parameter, Low-False-Alarm Fire-Detection Systems

Fire-detection systems incorporating multiple sensors that measure multiple parameters are being developed for use in storage depots, cargo bays of ships and aircraft, and other locations not amenable to frequent, direct visual inspection. These systems are intended to improve upon conventional smoke detectors, now used in such locations, that reliably detect fires but also frequently generate false alarms: for example, conventional smoke detectors based on the blockage of light by smoke particles are also affected by dust particles and water droplets and, thus, are often susceptible to false alarms. In contrast, by utilizing multiple parameters associated with fires, i.e. not only obscuration by smoke particles but also concentrations of multiple chemical species that are commonly generated in combustion, false alarms can be significantly decreased while still detecting fires as reliably as older smoke-detector systems do. The present development includes fabrication of sensors that have, variously, micrometer- or nanometer-sized features so that such multiple sensors can be integrated into arrays that have sizes, weights, and power demands smaller than those of older macroscopic sensors. The sensors include resistors, electrochemical cells, and Schottky diodes that exhibit different sensitivities to the various airborne chemicals of interest. In a system of this type, the sensor readings are digitized and processed by advanced signal-processing hardware and software to extract such chemical indications of fires as abnormally high concentrations of CO and CO2, possibly in combination with H2 and/or hydrocarbons. The system also includes a microelectromechanical systems (MEMS)-based particle detector and classifier device to increase the reliability of measurements of chemical species and particulates. In parallel research, software for modeling the evolution of a fire within an aircraft cargo bay has been developed. The model implemented in the software can describe the concentrations of chemical species and of particulate matter as functions of time. A system of the present developmental type and a conventional fire detector were tested under both fire and false-alarm conditions in a Federal Aviation Administration cargo-compartment- testing facility. Both systems consistently detected fires. However, the conventional fire detector consistently generated false alarms, whereas the developmental system did not generate any false alarms.

Hunter, Gary W.↗

Alpha particle detection with GaN Schottky diodes

Ni/GaN Schottky diode radiation detectors were fabricated on 3-mum-thick unintentionally doped n-GaN films grown by molecular beam epitaxy (MBE) and metal organic chemical vapor deposition (MOCVD) and on 12-mum-thick undoped n-GaN layers prepared by epitaxial lateral overgrowth (ELOG). The reverse current of all detector structures was <10{sup -9} A for bias voltages necessary for detector operation, with the level of background donor doping of <10{sup 15} cm{sup -3}. With this doping level the space charge region of the Schottky diode could be extended to the entire thickness of the films. The charge collection efficiency of the detectors was close to 100% for MOCVD and ELOG detectors for alpha-particles with range comparable to the thickness of the layer. Electrical properties and deep trap spectra were also studied. The collection efficiency decreased when the concentra-tion of deep electron traps, particularly E{sub c}-0.6 eV traps, increased in MBE grown films.

36 MATERIALS SCIENCE↗

Studying {sup 12}B via {sup 8}Li-{alpha} resonant scattering

The inverse kinematics thick target scattering method (TTIK) has been used to study the {sup 8}Li elastic scattering on {sup 4}He in order to investigate {sup 8}Li-{alpha} cluster configurations in excited states of {sup 12}B. A {sup 8}Li beam, provided by the radioactive beam facility EXCYT, at E{sub beam} = 30.6 MeV, passing through helium thick target, continuously decreases its energy inducing elastic scattering starting from the initial energy down to zero. Four {Delta}E-E double stage silicon detector telescopes were used to detect the recoil {alpha}-particles coming from the scattering. Event by event time measurement between beam particles passing through a MCP detector and {alpha}-particles impinging on {Delta}E stage allows elastic from inelastic events discrimination, thus representing an improvement of the TTIK method. In this paper the used experimental technique and some preliminary results will be briefly described.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A self-powered thin-film radiation detector using intrinsic high-energy current

Purpose: The authors introduce a radiation detection method that relies on high-energy current (HEC) formed by secondary charged particles in the detector material, which induces conduction current in an external readout circuit. Direct energy conversion of the incident radiation powers the signal formation without the need for external bias voltage or amplification. The detector the authors consider is a thin-film multilayer device, composed of alternating disparate electrically conductive and insulating layers. The optimal design of HEC detectors consists of microscopic or nanoscopic structures. Methods: Theoretical and computational developments are presented to illustrate the salient properties of the HEC detector and to demonstrate its feasibility. In this work, the authors examine single-sandwiched and periodic layers of Cu and Al, and Au and Al, ranging in thickness from 100 nm to 300 μm and separated by similarly sized dielectric gaps, exposed to 120 kVp x-ray beam (half-value thickness of 4.1 mm of Al). The energy deposition characteristics and the high-energy current were determined using radiation transport computations. Results: The authors found that in a dual-layer configuration, the signal is in the measurable range. For a defined total detector thickness in a multilayer structure, the signal sharply increases with decreasing thickness of the high-Z conductive layers. This paper focuses on the computational results while a companion paper reports the experimental findings. Conclusions: Significant advantages of the device are that it does not require external power supply and amplification to create a measurable signal; it can be made in any size and geometry, including very thin (sub-millimeter to submicron) flexible curvilinear forms, and it is inexpensive. Potential applications include medical dosimetry (both in vivo and external), radiation protection, and other settings where one or more of the above qualities are desired.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electromagnetic calorimeters based on scintillating lead tungstate crystals for experiments at Jefferson Lab

A new electromagnetic calorimeter consisting of 140 lead tungstate (PbWO 4 ) scintillating crystals was constructed for the PrimEx- &#x3B7; experiment at Jefferson lab. The calorimeter was integrated into the data acquisition and trigger systems of the GlueX detector and used in the experiment to reconstruct Compton scattering events. The experiment started collecting data in the spring of 2019 and acquired about 30% of the required statistics. The calorimeter is a prototype for two PbWO 4 -based detectors: the Neutral Particle Spectrometer (NPS) and the lead tungstate insert of the Forward CALorimeter (FCAL) of the GlueX detector. The article presents the design and performance of the Compton calorimeter and gives a brief overview of the FCAL and NPS projects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Acoustic Detection Of Loose Particles In Pressure Sensors

Particle-impact-noise-detector (PIND) apparatus used in conjunction with computer program analyzing output of apparatus to detect extraneous particles trapped in pressure sensors. PIND tester essentially shaker equipped with microphone measuring noise in pressure sensor or other object being shaken. Shaker applies controlled vibration. Output of microphone recorded and expressed in terms of voltage, yielding history of noise subsequently processed by computer program. Data taken at sampling rate sufficiently high to enable identification of all impacts of particles on sensor diaphragm and on inner surfaces of sensor cavities.

Kwok, Lloyd C.↗

A Cargo Inspection System for Special Nuclear Material (SNM) Based on Associated Particle Neutron Generators and Liquid-Kr Detectors

A feasibility analysis is presented of a cargo inspection system based on neutron-induced fission followed by the coincident detection of multiple prompt fission gamma rays as a signature of Special Nuclear Material (SNM). The system does not require gamma ray spectroscopy and would be capable of distinguishing U-238 from U-235 using the ratio of signals from two modes of detection: thermal neutron capture induced fission and fast neutron-induced fission. The system utilizes two deuterium-tritium (DT) associated particle neutron generators, each capable of 10{sup 9} neutrons/s at 14.1 MeV, with sub-nanosecond timing resolution ZnO:Ga alpha detectors. The expected {approx}1 MeV prompt gamma rays are detected using liquid krypton (LKr) detectors with sub-nanosecond timing resolution ({approx}600 ps) and high detection efficiency. The expected SNM signal and randomly correlated background rates are discussed using Monte Carlo N-Particle (MCNP) code.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Performance of the LHCb muon detector in Run 3

In Run 3 of the LHC, the instantaneous luminosity at the LHCb interaction point has been increased by a factor of five, from to $\mathscr{L}$ = 4 x 10 32 cm -2 s -2 to $\mathscr{L}$ = 2 x 10 33 cm -2 s -1 . Several hardware interventions, including a complete overhaul of the readout electronics, have been carried out on the muon detector. The muon identification algorithms in the software trigger were improved with the aim of ensuring Run 2 performance under a higher particle rate. The operation and calibration of the upgraded muon detector are presented. The muon detection efficiency and muon identification performance are evaluated on data calibration samples collected during the year 2024. A muon identification efficiency above 90% with sub-percent hadron misidentification probability is achieved by exploiting the pattern of hits in the muon detector.

Gaseous detectors↗

Signal formation in irradiated silicon detectors

In this paper we present an initial study on the effects induced by radiation on the signal generated by a minimum ionising particle in silicon detector. The results are obtained by implementing in the simulation programme Weightfield2 (WF2) charge carrier trapping and non linear distribution of the electric field. Results of sample simulations are presented, along with a discussion of the limitations of the current approach and ideas for future improvements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutrino Tridents in the NOvA Near Detector

NOvA is a long-baseline neutrino oscillation experiment based at Fermilab that uses theNuMI beam line and two detectors to measure neutrino rates at a near location, and 810 km away at a far location.The detectors are made from PVC extrusions which segment the volume in to 4x6 cm cells which alternate orientations to provide 3D tracking of particles in the detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗