Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Trace”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Fast Radiative Transfer Model and Retrieval Algorithm Development for Satellite Remote Sensing Applications

The radiative transfer model (RTM) has a wide range of applications in satellite remote sensing and atmospheric radiation studies. For example, it can be used as a forward model for an inversion algorithm and a satellite data assimilation system, or as a L1 data simulator for pre-launch end-to-end satellite sensor performance studies. However, millions of line-by-line (LBL) radiative transfer calculations at fine monochromatic frequencies are needed in order to properly calculate spectral contributions of water vapor and trace gases in the atmosphere in infrared and solar spectral regions. Therefore, fast, and accurate radiative transfer models are needed. A Principal Component-based radiative transfer model (PCRTM) was developed at NASA Langley to fulfil this need. The PCRTM can simulate the top-of-atmosphere (TOA) radiance or reflectance spectra from 250 nm to 2000 micrometers with several orders of magnitude faster speed as compared to a LBL RTM. It is also extremely accurate compared to LBL RTM benchmarks. The PCRTM model has been developed for hyperspectral sensors such as AIRS, CrIS, IASI, NAST-I, SHIS, CPF, TEMPO, EMIT, OMI, and SCIAMACHY. By using the PCRTM as forward model for an inversion algorithm, one can reduce the data dimension significantly while maintaining original information content by compressing the TOA radiance spectrum into PC-scores. The PCRTM can directly compute the PC-scores and their derivatives with respect to retrieved parameters. Examples of using various PCRTM inversion algorithms to retrieve atmospheric temperature, water vapor, and trace gas profiles, as well as cloud and surface properties from satellite hyperspectral remote sensors will be given. Some of the algorithms have been transitioned to NASA's Goddard Earth Sciences Data and Information Services Center (GES DISC) for public access of high-quality L2 and L3 data.

Xu Liu↗

Ammonia at Blodgett Forest, Sierra Nevada, USA

Ammonia is a reactive trace gas that is emitted in large quantities by animal agriculture and other sources in California, which subsequently forms aerosol particulate matter, potentially affecting visibility, climate, and human health. We performed initial measurements of NH{sub 3} at the Blodgett Forest Research Station (BFRS) during a two week study in June, 2006. The site is used for ongoing air quality research and is a relatively low-background site in the foothills of the Sierra Nevada. Measured NH{sub 3} mixing ratios were quite low (< 1 to {approx} 2 ppb), contrasting with typical conditions in many parts of the Central Valley. Eddy covariance measurements showed NH{sub 3} fluxes that scaled with measured NH{sub 3} mixing ratio and calculated aerodynamic deposition velocity, suggesting dry deposition is a significant loss mechanism for atmospheric NH{sub 3} at BFRS. A simple model of NH{sub 3} transport to the site supports the hypothesis that NH{sub 3} is transported from the Valley to BFRS, but deposits on vegetation during the summer. Further work is necessary to determine whether the results obtained in this study can be generalized to other seasons.

54 ENVIRONMENTAL SCIENCES↗

Slab-geometry Nd:glass laser performance studies

It is noted that slab-geometry solid-state lasers potentially provide significant performance improvements relative to conventional rod-geometry lasers. Experimental measurements that use an Nd:glass test-bed slab laser are presented. A comparison is made between the results and computer-model predictions of the slab-geometry approach. The computer model calculates and displays the temperature and stress fields in the slab, and on the basis of these predicts birefringence and index-of-refraction distributions. The effect that these distributions have on optical propagation is determined in a polarization-sensitive ray-tracing section of the model. Calculations are also made of stress-induced surface curvature and the resulting focusing effects. The measurements are found to be in good agreement with the computer-model predictions. It is concluded that the slab configuration offers significant laser-performance advantages in comparison with the traditional rod-laser geometry.

Eggleston, J. M.↗

Developmental long trace profiler using optimally aligned mirror based pentaprism

A low-budget surface slope measuring instrument, the Developmental Long Trace Profiler (DLTP), was recently brought into operation at the Advanced Light Source Optical Metrology Laboratory [Nucl. Instr. and Meth. A 616, 212-223 (2010)]. The instrument is based on a precisely calibrated autocollimator and a movable pentaprism. The capability of the DLTP to achieve sub-microradian surface slope metrology has been verified via cross-comparison measurements with other high-performance slope measuring instruments when measuring the same high-quality test optics. In the present work, a further improvement of the DLTP is achieved by replacing the existing bulk pentaprism with a specially designed mirror based pentaprism. A mirror based pentaprism offers the possibility to eliminate systematic errors introduced by inhomogeneity of the optical material and fabrication imperfections of a bulk pentaprism. We provide the details of the mirror based pentaprism design and describe an original experimental procedure for precision mutual alignment of the mirrors. The algorithm of the alignment procedure and its efficiency are verified with rigorous ray tracing simulations. Results of measurements of a spherically curved test mirror and a flat test mirror using the original bulk pentaprism are compared with measurements using the new mirror based pentaprism, demonstrating the improved performance.

47 OTHER INSTRUMENTATION↗

Source Attribution of Cyanides using Anionic Impurity Profiling, Stable Isotope Ratios, Trace Elemental Analysis and Chemometrics

Chemical attribution signatures (CAS) for chemical threat agents (CTAs) are being investigated to provide an evidentiary link between CTAs and specific sources to support criminal investigations and prosecutions. In a previous study, anionic impurity profiles developed using high performance ion chromatography (HPIC) were demonstrated as CAS for matching samples from eight potassium cyanide (KCN) stocks to their reported countries of origin. Herein, a larger number of solid KCN stocks (n = 13) and, for the first time, solid sodium cyanide (NaCN) stocks (n = 15) were examined to determine what additional sourcing information can be obtained through anion, carbon stable isotope, and elemental analyses of cyanide stocks by HPIC, isotope ratio mass spectrometry (IRMS), and inductively coupled plasma optical emission spectroscopy (ICP-OES), respectively. The HPIC anion data was evaluated using the variable selection methods of Fisher-ratio (F-ratio), interval partial least squares (iPLS), and genetic algorithm-based partial least squares (GAPLS) and the classification methods of partial least squares discriminate analysis (PLSDA), K nearest neighbors (KNN), and support vector machines discriminate analysis (SVMDA). In summary, hierarchical cluster analysis (HCA) of anion impurity profiles from multiple cyanide stocks from six reported country of origins resulted in cyanide samples clustering into three groups: Czech Republic, Germany, and United States, independent of the associated alkali metal (K or Na). The three country groups were independently corroborated by HCA of cyanide elemental profiles and corresponded to countries with known solid cyanide factories. Both the anion and elemental CAS are believed to originate from the aqueous alkali hydroxides used in cyanide manufacture. Carbon stable isotope measurements resulted in two clusters: Germany and United States (the single Czech stock grouped with United States stocks). The carbon isotope CAS is believed to originate from the carbon source and process used to make the HCN utilized in cyanide synthesis. Classification errors for two validation studies using anion impurity profiles collected over five years on different instruments were as low as zero for KNN and SVMDA, demonstrating the excellent reliability (so far) of using anion impurities for matching a cyanide sample to its country of manufacture (i.e., factory). Variable selection reduced errors for those classification methods having errors greater than zero with iPLS-forward selection, and F-ratio typically providing the lowest errors. Finally, using anion profiles to match cyanides to a specific stock or stock group resulted in cross-validation errors ranging from zero to 5.3%.

chemical forensics↗

Low Power Consumption Laser for Next Generation Miniature Optical Spectrometers for Trace Gas Analysis

The air quality of any manned spacecraft needs to be continuously monitored in order to safeguard the health of the crew. Air quality monitoring grows in importance as mission duration increases. Due to the small size, low power draw, and performance reliability, semiconductor laser-based instruments are viable candidates for this purpose. Achieving a minimum instrument size requires lasers with emission wavelength coinciding with the absorption of the fundamental absorption lines of the target gases, which are mostly in the 3.0-5.0 mu m wavelength range. In this paper we report on our progress developing high wall plug efficiency type-I quantum-well GaSb-based diode lasers operating at room temperatures in the spectral region near 3.0-3.5 mu m and quantum cascade (QC) lasers in the 4.0-5.0 mu m range. These lasers will enable the development of miniature, low-power laser spectrometers for environmental monitoring of the spacecraft

distributed feedback laser (DFB↗

Low Power Consumption Lasers for Miniature Optical Spectrometers for Trace Gas Analysis

The air quality of any manned spacecraft needs to be continuously monitored in order to safeguard the health of the crew. Air quality monitoring grows in importance as mission duration increases. Due to the small size, low power draw, and performance reliability, semiconductor laser-based instruments are viable candidates for this purpose. Achieving a minimum instrument size requires lasers with emission wavelength coinciding with the absorption of the fundamental absorption lines of the target gases, which are mostly in the 3.0-5.0 micron wavelength range. In this paper we report on our progress developing high wall plug efficiency type-I quantum-well GaSb-based diode lasers operating at room temperatures in the spectral region near 3.0-3.5 micron and quantum cascade (QC) lasers in the 4.0-5.0 micron range. These lasers will enable the development of miniature, low-power laser spectrometers for environmental monitoring of the spacecraft.

Distributed Feedback (DFB) Diode Lasers↗

Low Power Consumption Lasers for Next Generation Miniature Optical Spectrometers for Major Constituent and Trace Gas Analysis

The air quality of any manned spacecraft needs to be continuously monitored in order to safeguard the health of the crew. Air quality monitoring grows in importance as mission duration increases. Due to the small size, low power draw, and performance reliability, semiconductor laser-based instruments are viable candidates for this purpose. The minimum instrument size requires lasers with emission wavelength coinciding with the absorption of the fundamental frequency of the target gases which are mostly in the 3.0-5.0 micrometers wavelength range. In this paper we report on our progress developing high wall plug efficiency type-I quantum-well GaSb-based diode lasers operating at room temperatures in the spectral region near 3.0-3.5 micrometers and quantum cascade (QC) lasers in the 4.0-5.0 micrometers range. These lasers will enable the development of miniature, low-power laser spectrometers for environmental monitoring of the spacecraft.

semiconductor lasers↗

New Technologies for Cost-Effective High-Performance Remote Sensing from Space

Scientific exploration of the Solar System, astrophysics discoveries, and earth observations for weather and environment have had a profound effect on our understanding of the Universe. Modern sensors, propulsion, materials technology, planetary and astrophysics missions are briefly discussed, tracing the history of the applications of technology to space science missions in a few areas.

Technology↗

RP-2 Thermal Stability and Heat Transfer Investigation for Hydrocarbon Boost Engines

A series of electrically heated tube tests were performed at the NASA Glenn Research Center s Heated Tube Facility to investigate the use of RP-2 as a fuel for next generation regeneratively cooled hydrocarbon boost engines. The effect that test duration, operating condition and test piece material have on the overall thermal stability and materials compatibility characteristics of RP-2 were evaluated using copper and 304 stainless steel test sections. The copper tests were run at 1000 psia, heat flux up to 6.0 Btu/in.2-sec, and wall temperatures up to 1180 F. Preliminary results, using measured wall temperature as an indirect indicator of the carbon deposition process, show that in copper test pieces above approximately 850 F, RP-2 begins to undergo thermal decomposition resulting in local carbon deposits. Wall temperature traces show significant local temperature increases followed by near instantaneous drops which have been attributed to the carbon deposition/shedding process in previous investigations. Data reduction is currently underway for the stainless steel test sections and carbon deposition measurements will be performed in the future for all test sections used in this investigation. In conjunction with the existing thermal stability database, these findings give insight into the feasibility of cooling a long life, high performance, high-pressure liquid rocket combustor and nozzle with RP-2.

VanNoord, J. L.↗

Performance status of the Atmospheric Infrared Sounder ten years after launch

The Atmospheric Infrared Sounder (AIRS) is a hyperspectral infrared instrument on the EOS Aqua Spacecraft, launched on May 4, 2002. AIRS has 2378 infrared channels ranging from 3.7 μm to 15.4 μm and a 13.5 km footprint at nadir. The AIRS is a “facility” instrument developed by NASA as an experimental demonstration of advanced technology for remote sensing and the benefits of high resolution infrared spectra to science investigations. AIRS, in conjunction with the Advanced Microwave Sounding Unit (AMSU), produces temperature profiles with 1K/km accuracy on a global scale, as well as water vapor profiles and trace gas amounts for CO2, CO, SO2, O3 and CH4. AIRS data are used for weather forecasting, climate process studies and validating climate models. The AIRS instrument has far exceeded its required design life of 5 years, with over 10 years of operations as of September 2012. While the instrument has performed exceptionally well, with little signs of wear, the AIRS Project continues to monitor and maintain the health of AIRS, characterize its behavior and improve performance where possible. Radiometric stability has been monitored and trending shows better than 16 mK/year stability. Spectral calibration stability is better than 1 ppm/year, and a new gain table was recently uploaded to recover 100 significantly degraded or dead channels by switching to their redundant counterpart. At this time we expect the AIRS to continue to perform well for the next decade.

Strow, Larrabee↗

Nanostructured materials for selective collection of trace-level metals from aqueous systems.

Nanostructured materials for selective collection of trace-level metals from aqueous systems A critical ability for responding to situations involving environmental contaminants is the ability to quickly identify the contaminant(s) involved and the scope of the contamination. Simple field-screening methods are needed to enable on-site, information allocation and decision making. Currently, analytical technology does not exist to allow quick, accurate, and efficient analysis. Existing field-screening methods lack the selectivity and sensitivity needed to provide key information. A large leap in performance is needed and is very unlikely to be achieved with incremental improvements in procedure, instrument design, or improved electronics. A new analytical approach is required. Deficiencies in selectivity and sensitivity can be addressed with high-performance sorbent materials capable of selectively concentrating the target analytes and removing them from the sample matrix. By concentrating and removing the target analyte, these sorbent materials provide a well-defined matrix for analysis. This chapter examines the use of nanostructured materials for the selective collection of trace-level metals from aqueous systems. The focus lies on thiol-functionalized materials. Focusing on thiol surface chemistry allows comparison of mesoporous silica, activated carbon, and superparamagnetic nanoparticles. The chapter also discusses zeolites, imprinted polymer materials, and activated carbon in general. The materials reviewed here are evaluated based on capacity, selectivity, and affinity for target analytes. Research presented here shows that correctly constructed nanostructured materials are superior to conventional sorbents.

nanomaterials, nanostructures, SAMMS, trace level ↗

Variations in Creep Performance of P92 Steel Within Its Composition Range: Influence of N Solubility

Underspecified composition ranges often lead to alloys with unpredictable mechanical performance. To better understand the changes in microstructure and mechanical performance associated with variations of key elements, three versions of P92 are formulated within, or close to, the specified allowable for N, B, and C ranges. Chromium and Si are also varied to influence N solubility. Different service conditions (i.e., temperature and stress) are explored. It is observed that >80% decrease in creep life occurs at 625 °C and 155 MPa for the highest B and N containing alloy. Multiscale characterization reveals key changes due to the trace element variation. The high B and N containing alloy forms deleterious BN precipitates with morphology that promotes crack nucleation and damage accumulation, but this alloy additionally forms higher fractions of beneficial MX precipitates. The alloy with the lowest B and N concentrations but greater C content shows the best creep performance—a consequence of the refined M 23 C 6 carbide precipitate population and the absence of large-scale inclusions or BN precipitates. Calculations of creep activation energy reveal that the high B and N containing alloy is more prone to damage accumulation which causes an early onset of accelerating creep and greater minimum creep rate.

36 MATERIALS SCIENCE↗

Atmospheric Pre-Corrected Differential Absorption Techniques to Retrieve Columnar Water Vapor: Application to AVIRIS 91/95 Data

Water vapor is one of the main forces for weather development as well as for mesoscale air transport processes. The monitoring of water vapor is therefore an important aim in remote sensing of the atmosphere. Current operational systems for water vapor detection use primarily the emission in the thermal infrared (AVHRR, GOES, ATSR, Meteosat) or in the microwave radiation bands (DMSP). The disadvantage of current satellite systems is either a coarse spatial (horizontal) resolution ranging from one to tens of kilometers or a limited insight into the lower atmosphere. Imaging spectrometry on the other hand measures total column water vapor contents at a high spatial horizontal resolution and has therefore the potential of filling these gaps. The sensors of the AVIRIS instrument are capable of acquiring hyperspectral data in 224 bands located in the visible and near infrared at 10 nm resolution. This data includes the information on constituents of the earth's surface as well as of the atmosphere. The optical measurement of water vapor can be performed using sensor channels located in bands or lines of the absorption spectrum. The AVIRIS sensor has been used to retrieve water vapor and with less accuracy carbon dioxide, oxygen and ozone. To retrieve the water vapor amount, the so called differential absorption technique has been applied. The goal of this technique is to eliminate background factors by taking a ratio between channels within the absorption band and others besides the band. Various ratioing methods on the basis of different channels and calculation techniques were developed. The influence of a trace gas of interest on the radiance at the sensor level is usually simulated by using radiative transfer codes. In this study, the spectral transmittance and radiance are calculated by MODTRAN3 simulations with the new DISORT option. The objective of this work is to test the best performing differential absorption techniques for imaging spectrometry of tropospheric water vapor.

Schlaepfer, Daniel↗

Observing the onset of the accretion wake in Vela X-1

High-mass X-ray binaries (HMXBs) offer a unique opportunity to investigate accretion onto compact objects and the wind structure in massive stars. A key source for such studies is the bright neutron star HMXB Vela X-1 whose convenient physical and orbital parameters facilitate analyses and in particular enable studies of the wind structure in HMXBs. Here, we analyse simultaneous XMM-Newton and NuSTAR observations at $\phi_{orb}$ ≈ 0.36–0.52 and perform time-resolved spectral analysis down to the pulse period of the neutron star based on our previous NuSTAR-only results. For the first time, we are able to trace the onset of the wakes in a broad 0.5–78 keV range with a high-time resolution of ~283 s and compare our results with theoretical predictions. Here we observed a clear rise in the absorption column density of the stellar wind N H,1 starting at orbital phase ~0.44, corresponding to the wake structure entering our line of sight towards the neutron star, together with local extrema throughout the observation, which are possibly associated with clumps or other structures in the wind. Periods of high absorption reveal the presence of multiple fluorescent emission lines of highly ionised species, mainly in the soft-X-ray band between 0.5 and 4 keV, indicating photoionisation of the wind.

79 ASTRONOMY AND ASTROPHYSICS↗

High-Resolution X-ray Microprobe Using a Spatial Filter and Its Application to Micro-XAFS Measurements

An x-ray microprobe system with total-reflection mirror optics for trace element analysis has been developed at beamline 37XU of SPring-8. To achieve sub-microprobe, a spatial filter has been installed downstream of a monochromator. Focusing tests have been performed in the x-ray energy range of 6-14 keV. A focused beam size of 0.83 {mu}m(V)x1.35 {mu}m(H) has been obtained at an x-ray energy of 10 keV, and using a spatial filter in the horizontal direction, the beam size is down to 0.84 {mu}m. Micro-x-ray absorption fine structure (XAFS) spectroscopy of submicrometer particles has been done by utilizing the total-reflection mirror optics. It was clearly observed from the nickel K-edge XAFS spectra that the oxidation state of nickel was a mixture of metal and oxide even in the single submicrometer particle.

07 ISOTOPE AND RADIATION SOURCES↗

Existence of a robust optimal control process for efficient measurements in a two-qubit system

The verification of quantum entanglement is essential for quality control in quantum communication. In this work we propose an efficient protocol to directly verify the two-qubit entanglement of a known target state through a single-expectation-value measurement. Our method provides exact entanglement quantification using the concurrence measure without performing quantum state tomography. We prove the existence of a unitary transformation that drives a known initial state of a two-qubit system to a designated final state, where the trace over a chosen observable directly yields the concurrence of the initial state. Furthermore, we implement an optimal control process of that transformation and demonstrate its effectiveness through numerical simulations. We also show that this process is robust to environmental noise. Our approach offers advantages in directly verifying entanglement with low circuit depth, making it suitable for industrial-scale quality control of entanglement generation. Our results presented here provide mathematical justification for our earlier computational experiments.

Rodriguez, Ricardo [McPherson Coll.] (ORCID:000000↗