Search NASA⌕ Search

SEARCH · Search NASA

Results for “Physical Protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

ISR-1 Seminar: Nuclear Cloud Lofting

This report goes into detail about motivation, background, lofting methodologies (empirical, parcel methods, Navier-Stokes), DELFIC Model, validation, DIORAMA integration, and has the following conclusions: A parcel methodology was applied to develop the DIORAMA cloud lofting module. It is based on the DELFIC model and treats the cloud as a homogenous unit. It solves the set of 8 ODEs for cloud properties. It outputs the time history of the cloud height, radius, and other parameters. The cloud lofting module was tuned with 54 test cases. An iterative brute force search was carried out to find the best fit tuning parameters. The best fit parameters yielded average cloud height errors of 12.9% and 10.3% for the bottom and top, respectively. This all allows for more accurate modeling of the propagation of delayed gamma rays in DIORAMA.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Safeguards Technology Factsheet - Unattended Dual Current Monitor (UDCM)

The UDCM is a low-current measurement device designed to record sub-nano-amp to micro-amp currents from radiation detectors. The UDCM is a two-channel device that incorporates a Commercial-Off-The-Shelf (COTS) processor enabling both serial over USB as well as Ethernet communications. The instrument includes microSD and USB flash memory for data storage as well as a programmable High Voltage (HV) power supply for detector bias. The UDCM is packaged in the same enclosure, employs the same processor and has a similar user interface as the UMSR. A serial over USB communication line to the UDCM allows the use of existing versions of MIC software, while the Ethernet port is compatible with the new IAEA RAINSTORM communication protocol.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Review Facility Design Drawings M3FT-16LA040105011 - Safeguards and Security by Design for Used Fuel Extended Storage: 1.02.04.01.05 FT – 16LA04010501

This work package focuses on developing Best Practices for the design of security for, and domestic safeguarding (e.g. MC&A) of, a pilot-scale independent spent/used fuel storage facility consistent with conceptual design efforts in Nuclear Fuels Storage and Transportation (NFST) and Used Fuel Disposal (UFD) campaigns. This is a review of the basic design of the facility to determine a candidate list of accounting and control requirements that could be considered for safeguards and security purposes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Safeguards Technology Factsheet 3 He-free Neutron Coincidence Counter

A full scale thermal neutron coincidence counter (High Level Neutron Counter – Boron: HLNB) based on 3 He alternative detection technology was designed and built at LANL and field tested at Plutonium Conversion Development Facility (PCDF) of Japan Atomic Energy Agency (JAEA) during FY15. HLNB is based on boron-lined proportional plates that replace the traditional 3 He proportional tubes and was designed as a direct alternative to 3 He-based High Level Neutron Coincidence Counter (HLNC-II). During the JAEA field trial the HLNB demonstrated comparable performance to HLNC-II, which represents a key development in the area of 3 He alternative technologies and provides a complete demonstration of the technology for nuclear safeguards applications including high mass MOX samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

After Action Report - Kazakhstan NSDD July 2015

On Monday 20 July, Caterina Fox, Ruth Kips and Kim Knight were invited to participate in Kazakhstan's nuclear material inventory management working group meeting coordinated by Alexander Vasilliev as nuclear forensics subject matter experts. The meeting included participants from Kazakhstan's nuclear regulatory agency (CAESC, the Committee on Atomic and Energetic Supervision and Control) and 3 institutes 1. Institute of Nuclear Physics, INP (Almaty), 2. National Nuclear Center, NNC (Kurchatov), and 3. Ulba Metallurgical Plant, UMP (Oskemen). CAESC requested attendance of an MC&A expert, an IT Specialist, and a Physical Security Specialist from each site. The general meeting concerned considerations for creating unified or compatible systems for nuclear material inventory management. NSDD representatives provided an overview of nuclear forensics and presented considerations for developments of inventory management that might be synergistic with future consideration of development of a National Nuclear Forensics Library to support nuclear forensics investigations.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Simulating Supernova Light Curves

This report discusses supernova light simulations. A brief review of supernovae, basics of supernova light curves, simulation tools used at LANL, and supernova results are included. Further, it happens that many of the same methods used to generate simulated supernova light curves can also be used to model the emission from fireballs generated by explosions in the earth’s atmosphere.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Radiation-Triggered Surveillance for UF6 Monitoring

This paper recommends the use of radiation detectors, singly or in sets, to trigger surveillance cameras. Ideally, the cameras will monitor cylinders transiting the process area as well as the process area itself. The general process area will be surveyed to record how many cylinders have been attached and detached to the process between inspections. Rad-triggered cameras can dramatically reduce the quantity of recorded images, because the movement of personnel and equipment not involving UF6 cylinders will not generate a surveillance review file.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Correlates of Sensitive Technologies

By “Quantitative Empirical Analysis” (QEA) is intended the use of statistical methods to infer, from data that often tend to be of a historical nature, the characteristics of states that correlate with some designated dependent variable (e.g. proliferation of nuclear weapons). QEA is a well-established approach in the social sciences, but is not notably well-known among physical scientists, who tend to think of the social sciences as inherently qualitative. This article attempts to provide a snapshot of research, most of which has evolved over the past decade, involving the application of QEA to issues in which the dependent variable of interest is intended as some measure of nuclear proliferation. Standard practices in QEA are described, especially as they relate to data collection. The QEA approach is compared and contrasted to other quantitative approaches to studying proliferation-related issues, including a “figure of merit” approach that has largely been developed within the DOE complex, and two distinct methodologies termed in a recent US National Academy of Sciences study as “case by case” and “predefined framework.” Sample results from QEA applied to proliferation are indicated, as are doubts about such quantitative approaches. A simplistic decision-theoretic model of the optimal time for the international community to intervene in a possible proliferation scenario is used to illustrate the possibility of synergies between different approaches

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Uncertainties in the Standard Moments, the Derivation of the Y1 to Y8 parameters, and the Derivation of w 1 to w 8 for Feynman Histograms

Momentum is a neutron multiplicity analysis software package that calculates a variety of parameters associated with Feynman histograms. While most of these parameters are documented in Cifarelli and Smith-Nelson, there are some parameters which are not. Most prominent of these are the uncertainties in the standard moments, and this paper will explicitly document these parameters. This paper will also document the higher-order Y n parameters and their associated ω n functions because they may be useful for future applications. The generation of what is referred to as Feynman histograms is not explained here.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

On Line Enrichment Monitor (OLEM) UF 6 Tests for 1.5" Sch40 SS Pipe, Revision 1

As global uranium enrichment capacity under international safeguards expands, the International Atomic Energy Agency (IAEA) is challenged to develop effective safeguards approaches at gaseous centrifuge enrichment plants while working within budgetary constraints. The “Model Safeguards Approach for Gas Centrifuge Enrichment Plants” (GCEPs) developed by the IAEA Division of Concepts and Planning in June 2006, defines the three primary Safeguards objectives to be the timely detection of: 1) diversion of significant quantities of natural (NU), depleted (DU) or low-enriched uranium (LEU) from declared plant flow, 2) facility misuse to produce undeclared LEU product from undeclared feed, and 3) facility misuse to produce enrichments higher than the declared maximum, in particular, highly enriched uranium (HEU). The ability to continuously and independently (i.e. with a minimum of information from the facility operator) monitor not only the uranium mass balance but also the 235 U mass balance in the facility could help support all three verification objectives described above. Two key capabilities required to achieve an independent and accurate material balance are 1) continuous, unattended monitoring of in-process UF 6 and 2) monitoring of cylinders entering and leaving the facility. The continuous monitoring of in-process UF 6 would rely on a combination of load-cell monitoring of the cylinders at the feed and withdrawal stations, online monitoring of gas enrichment, and a high-accuracy net weight measurement of the cylinder contents. The Online Enrichment Monitor (OLEM) is the instrument that would continuously measure the time-dependent relative uranium enrichment, E(t), in weight percent 235 U, of the gas filling or being withdrawn from the cylinders. The OLEM design concept combines gamma-ray spectrometry using a collimated NaI(Tl) detector with gas pressure and temperature data to calculate the enrichment of the UF 6 gas within the unit header pipe as a function of time. The OLEM components have been tested on ORNL UF 6 flow loop. Data were collected at five different enrichment levels (0.71%, 2.97%, 4.62%, 6.0%, and 93.7%) at several pressure conditions. The test data were collected in the standard OLEM N.4242 file format for each of the conditions with a 10-minute sampling period and then averaged over the span of constant pressures. Analysis of the collected data has provided enrichment constants that can be used for 1.5” stainless steel schedule 40 pipe measurement sites. The enrichment constant is consistent among all the wide range of enrichment levels and pressures used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a Commercial Silicon Beta Cell

Silicon detectors are of interest for the verification of the Comprehensive Nuclear-Test-Ban Treaty (CTBT) due to their enhanced energy resolution compared to plastic scintillators beta cells. Previous work developing a figure-of-merit (FOM) for comparison of beta cells suggests that the minimum detectable activity (MDA) could be reduced by a factor of two to three with the use of silicon detectors. Silicon beta cells have been developed by CEA (France) and Lares Ltd. (Russia), with the PIPSBox developed by CEA being commercially available from Canberra for approximately $35k, but there is still uncertainty about the reproducibility of the capabilities in the field. PNNL is developing a high-resolution beta-gamma detector system in the shallow underground laboratory, which will utilize and characterize the operation of the PIPSBox detector. Throughout this report, we examine the capabilities of the PIPSBox as developed by CEA. The lessons learned through the testing and use of the PIPSBox will allow PNNL to strategically develop a silicon detector optimized to better suit the communities needs in the future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Figure-of-Merit for Beta Cell Detector Characterization

In order to decrease the minimum detectable activities (MDAs) of beta-gamma radioxenon detectors, it is important to increase the ability to resolve the individual isotopes. One proposed method for doing this is to increase the energy resolution of the beta cell through the use of silicon detectors. While silicon detectors can improve the energy resolution, it is accompanied with a decrease in detection efficiency compared to plastic scintillator beta cells. Due to the uncertainty on the impact of the competing variables, we have developed a figure-of-merit (FOM) capable of determining the impact of detector parameters on the MDAs. By utilizing the FOM to analyze different detectors, we are able to directly compare current and future detectors and estimate their impact on the radioxenon MDAs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Testing of the KRI-developed Silicon PIN Radioxenon Detector

Radioxenon detectors are used for the verification of the Comprehensive Nuclear-Test-Ban Treaty (CTBT) in a network of detectors throughout the world called the International Monitoring System (IMS). The Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) Provisional Technical Secretariat (PTS) has tasked Pacific Northwest National Laboratory (PNNL) with testing a V.G. Khlopin Radium Institute (KRI) and Lares Ltd-developed Silicon PIN detector for radioxenon detection. PNNL measured radioxenon with the silicon PIN detector and determined its potential compared to current plastic scintillator beta cells. While the PNNL tested Si detector experienced noise issues, a second detector was tested in Russia at Lares Ltd, which did not exhibit the noise issues. Without the noise issues, the Si detector produces much better energy resolution and isomer peak separation than a conventional plastic scintillator cell used in the SAUNA systems in the IMS. Under the assumption of 1 cm 3 of Xe in laboratory-like conditions, 24-hr count time (12-hr count time for the SAUNA), with the respective shielding the minimum detectable concentrations for the Si detector tested by Lares Ltd (and a conventional SAUNA system) were calculated to be: 131m Xe – 0.12 mBq/m 3 (0.12 mBq/m 3 ); 133 Xe – 0.18 mBq/m 3 (0.21 mBq/m 3 ); 133m Xe – 0.07 mBq/m 3 (0.15 mBq/m 3 ); 135 Xe – 0.45 mBq/m 3 (0.67 mBq/m 3 ). Detection limits, which are one of the important factors in choosing the best detection technique for radioxenon in field conditions, are significantly better than for SAUNA-like detection systems for 131m Xe and 133m Xe, but similar for 133 Xe and 135 Xe. Another important factor is the amount of “memory effect” or carry over signal from one radioxenon measurement to the subsequent sample. The memory effect is reduced by a factor of 10 in the Si PIN detector compared to the current plastic scintillator cells. There is potential for further reduction with the removal of plastics within the cell, which will need to be explored in future work. A third important parameter in choosing the best detection technique for radioxenon is the resolution of the electron detection. While the resolution is important in determining the minimum detectable concentration, it plays a larger role in source identification when there is a visible signal. The Silicon PIN diodes generated improved resolution over a similar plastic scintillator cell. With the improved resolution, it becomes easier to distinguish the radioxenon isomers ( 133m Xe and 131m Xe) from the 133 Xe beta continuum background. With the beta background from 133 Xe ever present with the detection of the isomers, the improved resolution proves vital in calculating the ratios of the three isotopes. With an accurate measurement of the isotopic ratios, the anthropogenic sources of radioxenon (medical isotope production and nuclear reactors) can be more accurately distinguished. Based on the results shown within this report, a Si PIN beta cell shows the potential to aid in the operation and discriminating power of the IMS for the CTBTO. However, there are a number of issues that need attention before a detector of this design would be reliable enough for field operations in the IMS. Issues that need develop include, but are not limited to: studying the robustness of the design in field conditions, eliminating or minimizing the noise and variability of individual Si detector elements, understanding the long-term gain stability of the Si detectors, and reducing the non-Si materials within the cell (i.e. the plastic housing).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fabrication of Gamma Detectors Based on Magnetic Ag:Er Microcalorimeters

This report discusses the photolithographic fabrication of ultra-high resolution gamma-ray detectors based on magnetic microcalorimeters (MMCs). The MMC uses a novel Er-doped silver sensor (Ag:Er) that is expected to have higher sensitivity than the Er-doped gold (Au:Er) sensors currently in use. The MMC also integrates the first-stage SQUID preamplifier on the same chip as the MMC gamma detector to increase its signal-to-noise ratio. In addition, the MMC uses a passive Ta-Nb heat switch to replace one of the common long-term failure points in earlier detectors. This report discusses the fabrication process we have developed to implement the proposed improvements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transition of Iodine Analysis to Accelerator Mass Spectrometry

The goal of the project, New Paradigms for Isotope Ratio Mass Spectrometry: Raising the Scientific Profile and Improved Performance for Accelerator Mass Spectrometry (AMS) and Thermal Ionization Mass Spectrometry (TIMS), is to ensure that the ongoing isotope ratio determination capability within the U.S. Department of Energy complex is the world’s best for application to nonproliferation. This report spells out the progress of Task 4, Transition of TIMS to AMS for Iodine Analysis, of the larger project. The subtasks under Task 4 and the accomplishments throughout the three year project life cycle are presented in this report. Progress was made in optimization of chemical extraction, determination of a detection limit for 127Iodine, production of standard materials for AMS analysis quality assurance, facilitation of knowledge exchange with respect to analyzing iodine on an AMS, cross comparison with a world-leading AMS laboratory, supercritical fluid extraction of iodine for AMS analysis and electrodeposition of seawater as a direct method of preparation for iodine analysis by AMS--all with the goal of minimizing the time required to stand up an AMS capability for iodine analysis of exposed air filters at INL. An effective extraction method has been developed and demonstrated for iodine analysis of exposed air filters. Innovative techniques to accomplish the cathode preparation for AMS analysis were developed and demonstrated and published. The known gap of a lack of available materials for reference standards in the analysis of iodine by AMS was filled by the preparation of homogenous materials that were calibrated against NIST materials. A minimum limit on the amount of abundant isotope in a sample was determined for AMS analysis. The knowledge exchange occurred with fantastic success. Scientists engaged the international AMS community at conferences, as well as in their laboratories for collaborative work. The supercritical fluid extraction work has positive data, but is not a replacement for leaching yet. The added seawater work has led to a good method and a possible publication. The focus of this project was to minimize the time to stand up the AMS capability, by having all the preparation and supporting functions worked out ahead of the instrument arrival. Due to all the preparatory work and its success, the instrument was delivered and turned over to the INL in February 2015. Since then, INL scientists have been successfully vetting the capabilities and accomplishing their own measurements that agree well with the leading laboratories of the world for iodine analysis by AMS. Initially, all AMS data was gathered on other laboratories instruments, but during the last six months data for this project has come from INL’s AMS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

RELAP-7 Theory Manual

This document summarizes the physical models and mathematical formulations used in the RELAP-7 code. In summary, the MOOSE based RELAP-7 code development is an ongoing effort. The MOOSE framework enables rapid development of the RELAP-7 code. The developmental efforts and results demonstrate that the RELAP-7 project is on a path to success. This theory manual documents the main features implemented into the RELAP-7 code. Because the code is an ongoing development effort, this RELAP-7 Theory Manual will evolve with periodic updates to keep it current with the state of the development, implementation, and model additions/revisions.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A kinematically complete, interdisciplinary, and co-institutional measurement of the 19 F(α,n) cross section for nuclear safeguards science

Alpha particles emitted from the decay of uranium in a UF 6 matrix can interact with fluorine and generate neutrons via the 19 F(α,n) 22 Na reaction. These neutrons can be used to determine the uranium content in a UF 6 storage cylinder. The accuracy of this self-interrogating, non-destructive assay (NDA) technique is, however, limited by the uncertainty of the 19 F(α,n) 22 Na cross section. We have performed complementary measurements of the 19 F(α,n) 22 Na reaction with both 4 He and 19 F beams to improve the precision of the 19 F(α,n) 22 Na cross section over the alpha energy range that encompasses common actinide alpha decay needed for NDA studies. We have determined an absolute cross section for the 19 F(α,n) 22 Na reaction to an average precision of 7.6% over the alpha energy range of 3.9 – 6.7 MeV. We utilized this cross section in a simulation of a 100 g spherical UF 6 assembly and obtained a change in neutron emission rate values of approximately 10-12%, and a significant (factor of 3.6) decrease in the neutron emission rate uncertainty (from 50-51% to 13-14%), compared to simulations using the old cross section. Our new absolute cross section enables improved interpretations of NDAs of containers of arbitrary size and configuration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗