Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Scintillation event imaging with a single photon avalanche diode camera

Position and time measurements of scintillation events encode information about the radiation source. Single photon avalanche diode (SPAD) arrays offer multiple-megapixel spatial resolution and tens of picoseconds temporal resolution for detecting single photons. Current lensless designs for measuring scintillation events use sensors that are lower in spatial resolution. Camera-based designs use sensors that are lower in temporal resolution or readout rate and cannot image individual interactions. Here we propose to image scintillation events in a thick, monolithic scintillator using a high-resolution SPAD camera. We demonstrate that a commercial SPAD camera is able to gather sufficient signal to image individual scintillation events and observe 3D shifts in their spatial distribution. Simulations show that a SPAD camera can localize individual scintillation events in 3D. We report direct imaging of gamma-ray interactions in a scintillator with a SPAD camera. The proposed design may allow to measure complex signatures of individual particles interacting in the scintillator.

47 OTHER INSTRUMENTATION↗

An instrument for 3D x-ray nano-imaging

We present an instrument dedicated to 3D scanning x-ray microscopy, allowing a sample to be precisely scanned through a beam while the angle of x-ray incidence can be changed. The position of the sample is controlled with respect to the beam-defining optics by laser interferometry. The instrument achieves a position stability better than 10 nm standard deviation. The instrument performance is assessed using scanning x-ray diffraction microscopy and we demonstrate a resolution of 18 nm in 2D imaging of a lithographic test pattern while the beam was defined by a pinhole of 3 {mu}m in diameter. In 3D on a test object of copper interconnects of a microprocessor, a resolution of 53 nm is achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of XeI and XeII velocity in the near exit plane of a low-power Hall effect thruster by light induced fluorescence spectroscopy

Near exit plane non-resonant light induced fluorescence spectroscopy is performed in a Hall effect low-power Xenon thruster at discharge voltage of 250 V and anode flow rate of 0.7 mg/s. Measurements of the axial and radial velocity components are performed, exciting the 6s{sup 2}[3/2]{sub 2}{sup o}{yields}6p{sup 2}[3/2]{sub 2} transition at 823.16 nm in XeI and the 5d[4]{sub 7/2}{yields}6p[3]{sub 5/2}{sup o} transition at 834.724 nm in XeII. No significant deviation from the thermal velocity is observed for XeI. Two most probable ion velocities are registered at a given position with respect to the thruster axis, which are mainly attributed to different areas of creation of ions inside the acceleration channel. The spatial resolution of the set-up is limited by the laser beam size (radius of the order of 0.5 mm) and the fluorescence collection optics, which have a view spot diameter of 8 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Crystal Structure of Iodotyrosine Deiodinase, a Novel Flavoprotein Responsible for Iodide Salvage in Thyroid Glands

The flavoprotein iodotyrosine deiodinase (IYD) salvages iodide from mono- and diiodotyrosine formed during the biosynthesis of the thyroid hormone thyroxine. Expression of a soluble domain of this membrane-bound enzyme provided sufficient material for crystallization and characterization by x-ray diffraction. The structures of IYD and two co-crystals containing substrates, mono- and diiodotyrosine, alternatively, were solved at resolutions of 2.0, 2.45, and 2.6 {angstrom}, respectively. The structure of IYD is homologous to others in the NADH oxidase/flavin reductase superfamily, but the position of the active site lid in IYD defines a new subfamily within this group that includes BluB, an enzyme associated with vitamin B{sub 12} biosynthesis. IYD and BluB also share key interactions involving their bound flavin mononucleotide that suggest a unique catalytic behavior within the superfamily. Substrate coordination to IYD induces formation of an additional helix and coil that act as an active site lid to shield the resulting substrate {center_dot} flavin complex from solvent. This complex is stabilized by aromatic stacking and extensive hydrogen bonding between the substrate and flavin. The carbon-iodine bond of the substrate is positioned directly over the C-4a/N-5 region of the flavin to promote electron transfer. These structures now also provide a molecular basis for understanding thyroid disease based on mutations of IYD.

08 HYDROGEN↗

A strategy for the selection of monovalent antibodies that span protein dimer interfaces

Ligand-induced dimerization is the predominant mechanism through which secreted proteins activate cell surface receptors to transmit essential biological signals. Cytokines are a large class of soluble proteins that dimerize transmembrane receptors into precise signaling topologies, but there is a need for alternative, engineerable ligand scaffolds that specifically recognize and stabilize these protein interactions. Recombinant antibodies can potentially serve as robust and versatile platforms for cytokine complex stabilization, and their specificity allows for tunable modulation of dimerization equilibrium. Here, we devised an evolutionary strategy to isolate monovalent antibody fragments that bridge together two different receptor subunits in a cytokine–receptor complex, precisely as the receptors are disposed in their natural signaling orientations. To do this, we screened a naive antibody library against a stabilized ligand– receptor ternary complex that acted as a “molecular cast” of the natural receptor dimer conformation. Our selections elicited “stapler” single-chain variable fragments (scFvs) of antibodies that specifically engage the interleukin-4 receptor heterodimer. The 3.1 Å resolution crystal structure of one such stapler revealed that, as intended, this scFv recognizes a composite epitope between the two receptors as they are positioned in the complex. Extending our approach, we evolved a stapler scFv that specifically binds to and stabilizes the interface between the interleukin-2 cytokine and one of its receptor subunits, leading to a 15-fold enhancement in interaction affinity. This demonstration that scFvs can be selected to recognize epitopes that span protein interfaces presents new opportunities to engineer structurally defined antibodies for a broad range of research and therapeutic applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A SIMULTANEOUS STACKING AND DEBLENDING ALGORITHM FOR ASTRONOMICAL IMAGES

Stacking analysis is a means of detecting faint sources using a priori position information to estimate an aggregate signal from individually undetected objects. Confusion severely limits the effectiveness of stacking in deep surveys with limited angular resolution, particularly at far-infrared to submillimeter wavelengths, and causes a bias in stacking results. Deblending corrects measured fluxes for confusion from adjacent sources; however, we find that standard deblending methods only reduce the bias by roughly a factor of 2 while tripling the variance. We present an improved algorithm for simultaneous stacking and deblending that greatly reduces bias in the flux estimate with nearly minimum variance. When confusion from neighboring sources is the dominant error, our method improves upon rms error by at least a factor of 3 and as much as an order of magnitude compared to other algorithms. This improvement will be useful for Herschel and other telescopes working in a source confused, low signal-to-noise regime.

79 ASTRONOMY AND ASTROPHYSICS↗

The (d,{sup 2}He) reaction on {sup 76}Se and the double-{beta}-decay matrix elements for A=76

The (d,{sup 2}He) charge-exchange reaction on {sup 76}Se was studied at an incident energy of 183 MeV. The outgoing two protons in the {sup 1}S{sub 0} state, referred to as {sup 2}He, were both momentum analyzed and detected by the same spectrometer and detector. The experiment was performed at KVI, Groningen, using the magnetic spectrometer BBS at three angular positions: 0 deg., 2.5 deg., and 5 deg. Excitation-energy spectra of the residual nucleus {sup 76}As were obtained with an energy resolution of about 120 keV (FWHM). Gamow-Teller (GT{sup +}) transition strengths were extracted up to 5 MeV and compared with those from an (n,p) experiment at low resolution. Together with the GT{sup -} transition strengths from the {sup 76}Ge(p,n) experiment leading to the same intermediate nucleus, the nuclear matrix element of the two-neutrino double-{beta} decay of {sup 76}Ge was evaluated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Observing the positions of spinning binary systems using LISA

We present an analysis of the expected angular and distance uncertainties of spinning binary systems as measured by the space-based gravitational-wave observatory LISA. We focus on two distinct cases: supermassive coalescing black holes at high redshift and nearby binary star systems with roughly constant orbital frequency. We calculate the uncertainties using least-squares parameter estimation of simulated waveforms that are accurate to 4/2 post-Newtonian order. Our results show that the presence of spin can decrease massive black hole distance and positional uncertainties by as much as factors of 10 and 100, respectively. In optimal circumstances, we find that LISA's massive black hole merger resolution can be as low as 10{sup -6} steradians. However, in low-mass binary systems the presence of spin tends to degrade LISA's resolution by anywhere from a factor of 3 to a factor of 100.

39↗

First experimental feasibility study of VIPIC: a custom-made detector for X-ray speckle measurements

The Vertically Integrated Photon Imaging Chip (VIPIC) was custom-designed for X-ray photon correlation spectroscopy, an application in which occupancy per pixel is low but high time resolution is needed. VIPIC operates in a sparsified streaming mode in which each detected photon is immediately read out as a time- and position-stamped event. This event stream can be fed directly to an autocorrelation engine or accumulated to form a conventional image. The detector only delivers non-zero data (sparsified readout), greatly reducing the communications overhead typical of conventional frame-oriented detectors such as charge-coupled devices or conventional hybrid pixel detectors. This feature allows continuous acquisition of data with timescales from microseconds to hours. In this work VIPIC has been used to measure X-ray photon correlation spectroscopy data on polystyrene latex nano-colliodal suspensions in glycerol and on colloidal suspensions of silica spheres in water. Relaxation times of the nano-colloids have been measured for different temperatures. These results demonstrate that VIPIC can operate continuously in the microsecond time frame, while at the same time probing longer timescales.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accurate Crystal Structure Refinement of La{sub 3}Ta{sub 0.25}Zr{sub 0.50}Ga{sub 5.25}O{sub 14}

An accurate X-ray diffraction study of a La{sub 3}Ta{sub 0.25}Zr{sub 0.50}Ga{sub 5.25}O{sub 14} single crystal (a = 8.2574(4) A, c = 5.1465(4) A, sp. gr. P321, Z = 1, R/R{sub w} = 0.62/0.57% for 4144 unique reflections and 91 parameters) has been performed with a simultaneous neutron diffraction analysis. Tantalum, zirconium, and gallium atoms are found to occupy the mixed octahedral position (symmetry 32). Gallium atoms and a few zirconium atoms are in the position on axis 2 in the tetrahedron. The tetrahedral position on axis 3 is completely occupied by gallium atoms, while the large polyhedron on axis 2 is occupied by lanthanum atoms. The high resolution and averaging of the results obtained in two independent X-ray experiments with the same sample provided accu- rate structural data, in particular, on the anharmonicity of thermal atomic vibrations (atomic displacements). The X-ray and neutron diffraction data on the atomic displacements are compared.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

24.1.3.1.1 - Frisch Grid CZT Spectrometer

Brookhaven National Laboratory (BNL) worked with FLIR System Inc., the manufacturer of the nanoRAIDER, to develop a handheld field deployable detector based on the novel position-sensitive virtual Frisch-grid (VFG) Cadmium-Zinc-Telluride (CdZnTe or CZT) detectors (with 1% FWHM at 662 keV or better energy resolution). The detector called nanoRAIDER-VFG would be an improvement to the current nanoRAIDER, which is a compact gamma-ray detection instrument manufactured by FLIR Systems Inc. that employs relatively lower-performing CZT hemispheric detectors (i.e., 3%-FWHM CZT detectors). The nanoRAIDER-VFG would have significantly improved accuracy of measurements while maintaining similar efficiency, as compared to the nanoRAIDER, for in-field analysis of nuclear materials and detection of undeclared activities during inspections conducted by the International Atomic Energy Agency (IAEA). Since the nanoRAIDER is currently used by the IAEA as part of its Complementary Access toolkit, a relatively quick acceptance of the nanoRAIDER-VFG for safeguards was anticipated. The nanoRAIDER-VFG project was undertaken to address the following items in the IAEA's Long-Term R&D Plan, 2012-2023: 2.2 (elemental and isotopic signatures of fuel cycle processes); 2.3 (detect signatures of undeclared activity and improve analysis); and 2.6 (detect process emanations). The high energy-resolution of the nanoRAIDER-VFG would also have had applicability to 3.2 (fissile content of metal mixtures containing actinides Np, Am, etc.). The project was not completed due to a change in priorities within FLIR.

36 MATERIALS SCIENCE↗

Identification of Final-State Neutrons in ANNIE

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26-ton gadolinium-loaded (Gd-loaded) water Cherenkov detector located on the Booster Neutrino beamline at Fermilab. ANNIE's primary physics objectives include measuring neutron multiplicity for neutrino-nucleus interactions and performing cross-section measurements of charge current quasi-elastic and neutral current quasi-elastic processes. These measurements aim to improve neutrino energy reconstruction and reduce uncertainties in current and future neutrino oscillation experiments. Additionally, ANNIE serves as a testbed for advanced technologies such as Large Area Picosecond Photodetectors (LAPPDs) and Water-Based Liquid Scintillator, which enhance vertex resolution and enable detection below the Cherenkov threshold. By leveraging the high neutron capture cross section of Gd-loaded water, ANNIE is well positioned to observe final-state neutrons in beam-correlated neutrino interactions. To constrain the uncertainties in the neutron capture efficiency and time within the detector, we have conducted multiple calibration campaigns using an AmBe source. The AmBe source is deployed at different locations of the tank to map the neutron capture efficiency and determine the expected neutron capture time. Additionally, the AmBe calibration data are used to define the precise neutron clustering that will be useful for identifying neutron-like clusters from neutrino interaction. In this poster, we will present the current status of the AmBe neutron calibration program and the development of neutron cluster definition for the ANNIE Experiment.

Ajana, Dhavalkumar [Florida State U.]↗

Modeling Time Dispersion Due to Optical Path Length Differences in Scintillation Detectors

In this paper, we characterize the nature of the time dispersion in scintillation detectors caused by path length differences of the scintillation photons as they travel from their generation point to the photodetector. Using Monte Carlo simulation, we find that the initial portion of the distribution (which is the only portion that affects the timing resolution) can usually be modeled by an exponential decay. The peak amplitude and decay time depend both on the geometry of the crystal, the position within the crystal that the scintillation light originates from, and the surface finish. In a rectangular parallelpiped LSO crystal with 3 mm × 3 mm cross section and polished surfaces, the decay time ranges from 10 ps (for interactions 1 mm from the photodetector) up to 80 ps (for interactions 50 mm from the photodetector). Over that same range of distances, the peak amplitude ranges from 100% (defined as the peak amplitude for interactions 1 mm from the photodetector) down to 4% for interactions 50 mm from the photodetector. Higher values for the decay time are obtained for rough surfaces, but the exact value depends on the simulation details. Finally, estimates for the decay time and peak amplitude can be made for different cross section sizes via simple scaling arguments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A digitizer based compact digital spectrometer for ion beam analysis using field programmable gate arrays and various energy algorithms

We report on the implementation of a compact multi-detector fully digital spectrometer and data acquisition system at a nuclear microprobe for ion beam analysis and imaging. The spectrometer design allows for system scalability with no restriction on the number of detectors. It consists of four-channel high-speed digitizer modules for detector signal acquisition and one low-speed digital-to-analog converter (DAC) module with two DAC channels and additional general purpose inputs/outputs to control ion beam scanning and data acquisition. Each digitizer module of the spectrometer provides its own Field Programmable Gate Array (FPGA) as digital signal processing unit to analyze detector signals as well as to synchronize the ion beam position in hard real-time. With the customized FPGA designs for all modules, all calculation intensive tasks are executed inside the modules, which reduces significantly the data stream to and CPU load on the control computer. To achieve an optimal energy resolution for all detector/preamplifier pulse shape characteristics, a user-definable infinite impulse response filter with high throughput for energy determination was implemented. The new spectrometer has an online data analysis feature, a compact size, and is able to process any type of detector signals such as particle induced x-ray emission, Rutherford backscattering spectrometry, or scanning transmission ion microscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved Constraints on the Disk around MWC 349A from the 23 m LBTI

We present new spatially resolved observations of MWC 349A from the Large Binocular Telescope Interferometer (LBTI), a 23 m baseline interferometer made up of two, co-mounted 8 m telescopes. MWC 349A is a B[e] star with an unknown evolutionary state. Proposed scenarios range from a young stellar object, to a B[e] supergiant, to a tight binary system. Radio continuum and recombination line observations of this source revealed a sub-arcsecond bipolar outflow surrounding an ∼100 mas circumstellar disk. Follow-up infrared studies detected the disk, and suggested that it may have skew and an inner clearing. Our new infrared interferometric observations, which have more than twice the resolution of previously published data sets, support the presence of both skew and a compact infrared excess. They rule out inner clearings with radii greater than ∼14 mas. We show the improvements in disk parameter constraints provided by LBTI, and discuss the inferred disk parameters in the context of the posited evolutionary states for MWC 349A.

79 ASTRONOMY AND ASTROPHYSICS↗

Two-Dimensional Measurement of n+-p Asymmetrical Junctions in Multicrystalline Silicon Solar Cells Using AFM-Based Electrical Techniques with Nanometer Resolution: Preprint

Lateral inhomogeneities of modern solar cells demand direct electrical imaging with nanometer resolution. We show that atomic force microscopy (AFM)-based electrical techniques provide unique junction characterizations, giving a two-dimensional determination of junction locations. Two AFM-based techniques, scanning capacitance microscopy/spectroscopy (SCM/SCS) and scanning Kelvin probe forcemicroscopy (SKPFM), were significantly improved and applied to the junction characterizations of multicrystalline silicon (mc-Si) cells. The SCS spectra were taken pixel by pixel by precisely controlling the tip positions in the junction area. The spectra reveal distinctive features that depend closely on the position relative to the electrical junction, which allows us to indentify theelectrical junction location. In addition, SKPFM directly probes the built-in potential over the junction area modified by the surface band bending, which allows us to deduce the metallurgical junction location by identifying a peak of the electric field. Our results demonstrate resolutions of 10-40 nm, depending on the techniques (SCS or SKPFM). These direct electrical measurements withnanometer resolution and intrinsic two-dimensional capability are well suited for investigating the junction distribution of solar cells with lateral inhomogeneities.

14 SOLAR ENERGY↗

Achieving High-Resolution Hard X-ray Microscopy using Monolithic 2D Multilayer Laue Lenses

This article introduces the 2D multilayer Laue lens (MLL) nanofocusing optics recently developed for high-resolution hard X-ray microscopy. The new optics utilized a micro-electro-mechanical-system (MEMS)-based template to accommodate two linear MLL optics in a pre-aligned configuration. Angular misalignment between the two lenses was controlled in tens of millidegrees, and the lateral position error was on a micrometer scale. Using the developed 2D MLLs, an astigmatism-free point focus of approximately 14 nm by 13 nm in horizontal and vertical directions, respectively, at 13.6 keV photon energy was obtained. In conclusion, the success of 2D MLL optics with an approaching 10 nm resolution is a significant step forward for the development of high-resolution hard X-ray microscopy and applications of MLL optics in the hard X-ray community.

36 MATERIALS SCIENCE↗