Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Understanding the diversity of the West African monsoon system change projected by CORDEX-CORE regional climate models

Understanding real uncertainties in projections is needed to support actions of decision and policy makers. In this study, two state-of-the-art regional climate models with ~ 25 km horizontal resolution forced with three different global climate models are employed to investigate the response of the West African Monsoon (WAM) system under the low (RCP2.6) and high (RCP8.5) emission scenarios. We make a step towards assessing the plausibility of rainfall change (ΔPr) patterns based on the models’ ability to realistically represent the WAM system under the historical period, and by analyzing changes in mechanisms associated with ΔPr patterns. Under global warming, experiments exhibit diverse ΔPr patterns underpinned by different combinations of mechanisms operating simultaneously. A dipole-like surface pressure change between the Sahara Desert and the Guinea Coast appears to be a differentiating factor between experiments featuring homogeneous or increased rainfall over all or a part of the Sahel from those simulating heterogeneous or reduced rainfall over the same domain. This dipole acts by modulating the amount and the extent of deepening of the monsoon flux inland, and hence the latitudinal positioning of the monsoon convective system. This process contributes to moistening the whole or central and eastern Sahel in some experiments while drying the Guinea Coast. The West African Westerly Jet (WAWJ) is responsible for strengthening and moistening the western Sahel under RCP2.6. However, the WAMJ becomes much stronger under RCP8.5 and may have contributed to the drying of the western Sahel by shifting moisture eastwards in addition to the mid-tropospheric moisture divergence through enhanced African Easterly Jet. Furthermore, for experiments expecting wetting (drying) of the Sahel, the strengthening (weakening) of the tropical easterly jet may have contributed to the projected intensification (reduction) of WAM rainfall by favoring uplift (downlift) above 600 hPa. It also emerges that the ΔPr patterns from REMO2015 experiments are likely more plausible than those from RegCM4-v7. The impacts of strong warming on the regional hydrological cycle are further investigated and we found that changes gradually intensify with the level of radiative forcing, highlighting the importance of mitigating warming as recommended by the Paris agreement.

CORDEX-CORE↗

Evaluation of the geometric accuracy of surrogate-based gated VMAT using intrafraction kilovoltage x-ray images

Purpose: To evaluate the geometric accuracy of beam targeting in external surrogate-based gated volumetric modulated arc therapy (VMAT) using kilovoltage (kV) x-ray images acquired during dose delivery. Methods: Gated VMAT treatments were delivered using a Varian TrueBeam STx Linac for both physical phantoms and patients. Multiple gold fiducial markers were implanted near the target. The reference position was created for each implanted marker, representing its correct position at the gating threshold. The gating signal was generated from the RPM system. During the treatment, kV images were acquired immediately before MV beam-on at every breathing cycle, using the on-board imaging system. All implanted markers were detected and their 3D positions were estimated using in-house developed software. The positioning error of a marker is defined as the distance of the marker from its reference position for each frame of the images. The overall error of the system is defined as the average over all markers. For the phantom study, both sinusoidal motion (1D and 3D) and real human respiratory motion was simulated for the target and surrogate. In the baseline case, the two motions were synchronized for the first treatment fraction. To assess the effects of surrogate-target correlation on the geometric accuracy, a phase shift of 5% and 10% between the two motions was introduced. For the patient study, intrafraction kV images of five stereotactic body radiotherapy (SBRT) patients were acquired for one or two fractions. Results: For the phantom study, a high geometric accuracy was achieved in the baseline case (average error: 0.8 mm in the superior-inferior or SI direction). However, the treatment delivery is prone to geometric errors if changes in the target-surrogate relation occur during the treatment: the average error was increased to 2.3 and 4.7 mm for the phase shift of 5% and 10%, respectively. Results obtained with real human respiratory curves show a similar trend. For a target with 3D motion, the technique is able to detect geometric errors in the left-right (LR) and anterior-posterior (AP) directions. For the patient study, the average intrafraction positioning errors are 0.8, 0.9, and 1.4 mm and 95th percentile errors are 1.7, 2.1, and 2.7 mm in the LR, AP, and SI directions, respectively. Conclusions: The correlation between external surrogate and internal target motion is crucial to ensure the geometric accuracy of surrogate-based gating. Real-time guidance based on kV x-ray images overcomes the potential issues in surrogate-based gating and can achieve accurate beam targeting in gated VMAT.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatially Adaptive Tunable Lighting Control System with Expanded Wellness and Energy Saving Benefits

Lighting design is becoming increasingly complex, including active dimming for energy savings and spectral tuning for human wellbeing. Modern commercial lighting control systems are already difficult to use, and maintain, and even with so-called Smart Lighting, optimizing light settings is rapidly exceeding the capabilities of direct human control, limiting the adoption of lighting control systems. The growing importance of Occupancy Centric Controls (OCC) for advanced building management systems can be applied to the development of autonomous lighting system controls needed to drive the adoption of advanced lighting controls for improved adaptive “sculpted illumination” for both greater energy savings and broader human wellbeing perspectives. This project, led by Rensselaer Polytechnic Institute, entitled “Spatially adaptive tunable lighting control system with expanded wellness and energy saving benefits” will develop and test an entirely new platform for automated optimized lighting design and control that requires little or no human engagement, yet contours lighting profiles automatically to minimize lighting energy use. We call this approach to lighting control “dynamic light sculpting” since the right amount of illumination is automatically delivered to occupants in real time. Since the system uses new, privacy-preserving occupant position and pose detection technologies developed by Rensselaer for broad OCC building applications, the control system will analyze how to deliver the right amount of the right type of illumination only where and when it is needed based these OCC platforms. To create these powerful autonomous lighting control platforms, the project will integrate evolving augmented reality (AR) and virtual reality (VR) tools with sophisticated lighting and interior design toolkits to create interactive lighting design and control simulators. Using the quickly growing paradigm of digital twins, these tools will integrate light fixture properties, occupancy sensor data, interior design data, and lighting specifications to accurately visualize how various design concepts interact with simulated yet realistic human activities that occur in commercial office buildings of various types. These advanced digital twin design and simulation tools will be combined with a new class of digitally-programmable LED lighting fixtures that can dynamically change the spectral content and direction of light emission. When fully integrated, the new autonomous lighting control system will take all of the guesswork out of optimizing light quality while minimizing energy consumption. Digital twin tools will simplify the design, installation, commissioning, operation, and maintenance of future energy-efficient lighting systems. It should be possible to reduce lighting energy costs from 40% to 70% with OCC based dynamic light sculpting systems. The work will be led by the Center for Lighting Enabled Systems and Applications (LESA) and the Center for Architectural Science and Ecology (CASE), both at Renssealer Polytechnic Institute; Lumileds, a global leader in the development of advanced LED systems; and HKS, a leading global architecture design firm. This interdisciplinary project team’s experience includes all of the design simulation tools, VR/AR digital twin visualization technology, advanced occupancy sensing technology, and complex control system design capabilities that will revolutionize lighting design and control technology to autonomously deliver high-quality lighting that improves human health and wellbeing while simultaneously maximizing lighting energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mexico and the 21st Century Power Partnership (Fact Sheet)

The 21st Century Power Partnership's program in Mexico (21CPP Mexico) is one initiative of the Clean Energy Ministerial, carried out in cooperation with government and local stakeholders, drawing upon an international community of power system expertise. The overall goal of this program is to support Mexico's power system transformation by accelerating the transition to a reliable, financially robust, and low-carbon system. 21CPP Mexico activities focus on achieving positive outcomes for all participants, especially addressing critical questions and challenges facing policymakers, regulators, and system operators. In support of this goal, 21CPP Mexico taps into deep networks of expertise and professional connections.

21ST CENTURY POWER↗

Reduced Silicon Usage in Flat Photo-Voltaic Panels

Silicon usage in fixed, flat-panel photovoltaic systems can be reduced by 60 to 75% with no efficiency loss through use of arrays of mini-concentrators. These concentrators are simple trough-like reflectors that are formed in flat sheets of ~1- mm thick optical plastic. Concentration ratios of 2.55X can be achieved on rooftops and 4.0X on walls while collecting all of the direct sun and scattered skylight. The concentrators are fabricated in optical plastic— preferably polycarbonate for its high refractive index. The panels are typically 1mm thick so the weight of a panel is ~1kg/m 2 . In addition to the rooftop, wall and window blind designs, a design is proposed that can be tilted toward the sun position at the equinox. These systems are all designed so they can be mass-produced.

14 SOLAR ENERGY↗

Image-Guided Localization Accuracy of Stereoscopic Planar and Volumetric Imaging Methods for Stereotactic Radiation Surgery and Stereotactic Body Radiation Therapy: A Phantom Study

Purpose: To evaluate the positioning accuracies of two image-guided localization systems, ExacTrac and On-Board Imager (OBI), in a stereotactic treatment unit. Methods and Materials: An anthropomorphic pelvis phantom with eight internal metal markers (BBs) was used. The center of one BB was set as plan isocenter. The phantom was set up on a treatment table with various initial setup errors. Then, the errors were corrected using each of the investigated systems. The residual errors were measured with respect to the radiation isocenter using orthogonal portal images with field size 3 x 3 cm{sup 2}. The angular localization discrepancies of the two systems and the correction accuracy of the robotic couch were also studied. A pair of pre- and post-cone beam computed tomography (CBCT) images was acquired for each angular correction. Then, the correction errors were estimated by using the internal BBs through fiducial marker-based registrations. Results: The isocenter localization errors ({mu} {+-}{sigma}) in the left/right, posterior/anterior, and superior/inferior directions were, respectively, -0.2 {+-} 0.2 mm, -0.8 {+-} 0.2 mm, and -0.8 {+-} 0.4 mm for ExacTrac, and 0.5 {+-} 0.7 mm, 0.6 {+-} 0.5 mm, and 0.0 {+-} 0.5 mm for OBI CBCT. The registration angular discrepancy was 0.1 {+-} 0.2{sup o} between the two systems, and the maximum angle correction error of the robotic couch was 0.2{sup o} about all axes. Conclusion: Both the ExacTrac and the OBI CBCT systems showed approximately 1 mm isocenter localization accuracies. The angular discrepancy of two systems was minimal, and the robotic couch angle correction was accurate. These positioning uncertainties should be taken as a lower bound because the results were based on a rigid dosimetry phantom.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-BRE-16: VMAT Commissioning and Quality Assurance (QA) of An Elekta Synergy-STM Linac Using ICOM Test HarnessTM

Purpose: To establish a set of tests based on the iCOM software that can be used to commission and perform periodic QA of VMAT delivery on the Elekta Synergy-S, commonly known as the Beam Modulator (BM). Methods: iCOM is used to create and deliver customized treatment fields to characterize the system in terms of 1) MLC positioning accuracy under static and dynamic delivery with full gantry rotation, 2) MLC positioning with known errors, 3) Maximum dose rate, 4) Maximum MLC speed, 5) Maximum gantry speed, 6) Synchronization: gantry speed versus dose rate, and 7) Synchronization: MLC speed versus dose rate. The resulting images were captured on the iView GT and exported in DICOM format to Dosimetry Check™ system for visual and quantitative analysis. For the initial commissioning phase, the system tests described should be supplemented with extensive patient QAs covering all clinically relevant treatment sites. Results: The system performance test suite showed that on our Synergy-S, MLC positioning was accurate under both static and dynamic deliveries. Intentional errors of 1 mm were also easily identified on both static and dynamic picket fence tests. Maximum dose rate was verified with stop watch to be consistently between 475-480 MU/min. Maximum gantry speed and MLC speed were 5.5 degree/s and 2.5 cm/s respectively. After accounting for beam flatness, both synchronization tests, gantry versus dose rate and MLC speed versus dose rate, were successful as the fields were uniform across the strips and there were no obvious cold/hot spots. Conclusion: VMAT commissioning and quality assurance should include machine characterization tests in addition to patient QAs. Elekta iCOM is a valuable tool for the design of customized VMAT field with specific MU, MLC leaf positions, dose rate, and indirect control of MLC and gantry speed at each of its control points.

07 ISOTOPE AND RADIATION SOURCES↗

Tests of Scintillator+WLS Strips for Muon System at Future Colliders

Prototype scintilator+WLS strips with SiPM readout for muon system at future colliders were tested for light yield, time resolution and position resolution. Depending on the configuration, light yield of up to 36 photoelectrons per muon per SiPM has been achieved, as well as time resolution of 0.5 ns and position resolution of ~ 7 cm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cycloidal magnetic gear system

A cycloidal magnetic gear system for a turbine system is disclosed. The system includes a first stator magnet ring, a second stator magnet ring positioned opposite the first stator magnet ring, and a rotor positioned between the first and second stator rings of magnets. The rotor may include a first side positioned adjacent the first stator magnet ring, and a second side positioned adjacent the second stator magnet ring. The system may include a first rotor magnet ring affixed to the first side of the rotor, adjacent the first stator magnet ring. Additionally, the system may include a second rotor magnet ring affixed to the second side of the rotor, adjacent the second stator magnet ring. The rotor may be configured to rotate eccentrically about a center-axis of the first and/or second stator magnet ring.

Morris, Emily A.↗

Development of the Triple Theta assembly station with machine vision feedback

Increased requirements for tighter tolerances on assembled target components in complex three-dimensional geometries with only days to assemble complete campaigns require the implementation of a computer-controlled high-precision assembly station. Over the last year, an 11-axis computer-controlled assembly station has been designed and built with custom software to handle the multiple coordinate systems and automatically calculate all relational positions. Preliminary development efforts have also been done to explore the benefit of a machine vision feedback module with a dual-camera viewing system to automate certain basic features like crosshair calibration, component leveling, and component centering.

36 MATERIALS SCIENCE↗

TU-AB-201-03: A Robot for the Automated Delivery of An Electromagnetic Tracking Sensor for the Localization of Brachytherapy Catheters

Purpose: To present a programmable robotic system for the accurate and fast deployment of an electromagnetic (EM) sensor for brachytherapy catheter localization. Methods: A robotic system for deployment of an EM sensor was designed and built. The system was programmed to increment the sensor position at specified time and space intervals. Sensor delivery accuracy was measured in a phantom using the localization of the EM sensor and tested in different environmental conditions. Accuracy was tested by measuring the distance between the physical locations reached by the sensor (measured by the EM tracker) and the intended programmed locations. Results: The system consisted of a stepper motor connected to drive wheels (that grip the cable to move the sensor) and a series of guides to connect to a brachytherapy transfer tube, all controlled by a programmable Arduino microprocessor. The total cost for parts was <$300. The positional accuracy of the sensor location was within 1 mm of the expected position provided by the motorized guide system. Acquisition speed to localize a brachytherapy catheter with 20 cm of active length was 10 seconds. The current design showed some cable slip and warping depending on environment temperature. Conclusion: The use of EM tracking for the localization of brachytherapy catheters has been previously demonstrated. Efficient data acquisition and artifact reduction requires fast and accurate deployment of an EM sensor in consistent, repeatable patterns, which cannot practically be achieved manually. The design of an inexpensive, programmable robot allowing for the precise deployment of stepping patterns was presented, and a prototype was built. Further engineering is necessary to ensure that the device provides efficient independent localization of brachytherapy catheters. This research was funded by the Kaye Family Award.

60 APPLIED LIFE SCIENCES↗

Facet-Dependent Kinetics and Energetics of Hematite for Solar Water Oxidation Reactions

Currently, the performance of a photoelectrochemical (PEC) system is highly dependent on the charge separation, transport and transfer characteristics at the photoelectrode|electrolyte interface. Of the factors that influence the charge behaviors, the crystalline facets of the semiconductor in contact with the electrolyte play an important role but has been poorly studied previously. Here, we present a study aimed at understanding how the different facets of hematite affect the charge separation and transfer behaviors in a solar water oxidation reaction. Specifically, hematite crystallites with predominantly {012} and {001} facets exposed were synthesized. Density functional theory (DFT) calculations revealed that hematite {012} surfaces feature higher OH coverage, which was confirmed by X-ray photoelectron spectroscopy (XPS). These surface OH groups act as active sites to mediate water oxidation reactions, which plays a positive role for the PEC system. These surface OH groups also facilitate charge recombination, which compromises the charge separation capabilities of hematite. Moreover, intensity modulated photocurrent spectroscopy (IMPS) confirmed that hematite {012} surfaces exhibit higher rate constants for both charge transfer and recombination. Open circuit potential (OCP) measurements revealed that the hematite {012} surface reflects a greater degree of Fermi level pinning effect. Our results shed light on how different surface crystal structures may change surface kinetics and energetics. The information is anticipated to contribute to efforts on optimizing PEC performance for practical solar fuel synthesis.

36 MATERIALS SCIENCE↗

ASTROMETRY.NET: BLIND ASTROMETRIC CALIBRATION OF ARBITRARY ASTRONOMICAL IMAGES

We have built a reliable and robust system that takes as input an astronomical image, and returns as output the pointing, scale, and orientation of that image (the astrometric calibration or World Coordinate System information). The system requires no first guess, and works with the information in the image pixels alone; that is, the problem is a generalization of the 'lost in space' problem in which nothing-not even the image scale-is known. After robust source detection is performed in the input image, asterisms (sets of four or five stars) are geometrically hashed and compared to pre-indexed hashes to generate hypotheses about the astrometric calibration. A hypothesis is only accepted as true if it passes a Bayesian decision theory test against a null hypothesis. With indices built from the USNO-B catalog and designed for uniformity of coverage and redundancy, the success rate is >99.9% for contemporary near-ultraviolet and visual imaging survey data, with no false positives. The failure rate is consistent with the incompleteness of the USNO-B catalog; augmentation with indices built from the Two Micron All Sky Survey catalog brings the completeness to 100% with no false positives. We are using this system to generate consistent and standards-compliant meta-data for digital and digitized imaging from plate repositories, automated observatories, individual scientific investigators, and hobbyists. This is the first step in a program of making it possible to trust calibration meta-data for astronomical data of arbitrary provenance.

07 ISOTOPE AND RADIATION SOURCES↗

An Observational Evaluation of RKW Theory over the U.S. Southern Great Plains

The theory of Rotunno et al. (“RKW” theory) addresses the behavior of squall-line cold pools in vertically sheared flows. It predicts that, within a given thermodynamic environment, a balance between baroclinic vorticity generation by the cold pool and low-level environmental vertical wind shear induces an upright updraft along the gust front that maximizes the initiation of new convective cells. Although this theory has been evaluated numerically, its applicability to observed systems remains unclear and is limited by a lack of critical measurements, including high-frequency thermodynamic and wind profiles across the gust front. Herein, observations from the Atmospheric Radiation Measurement Southern Great Plains (ARM-SGP) observatory near Lamont, Oklahoma, are used to evaluate RKW theory for 10 well-observed squall lines over a 11-yr period. For this evaluation, RKW parameters including cold-pool intensity (c), low-level ambient, line-normal vertical shear (ΔV n ), subcloud and cloud-layer updraft tilts, and multiple measures of system intensity are estimated. Furthermore, the c estimates rely on thermodynamic retrievals from the Atmosphere Emitted Radiance Interferometer (AERI), which are uncertain but verify reasonably well against independent observations. As predicted by the theory, for c/ΔV n ≥ 1, c/ΔV n correlates positively with updraft tilt and negatively with system intensity, but these results are not always statistically significant and are also sensitive to the method by which ΔV n is evaluated. Specifically, ΔV n evaluations that extend above the cold-pool top yield greater consistency with RKW predictions. Also, some measures of intensity correlate more strongly with standard moist instability metrics than with RKW parameters.

Cold pools↗

SU-E-T-228: Liquid Ionisation Chamber Array and MicroDiamond Measurements with the CyberKnife System

Purpose: The aim of this study was to measure the dose profile and output factors with a CyberKnife accelerator using a TM60019 microDiamond detector and a 1000SRS liquid chamber array (both PTW Freiburg, Germany). Methods: An MP3 water phantom (PTW, Freiburg) was positioned along the robotic world coordinate system. The TM60019 detector was adjusted to the center of the according fields and the semiconductor axis was aligned with the beam direction. Profiles at 5cm water depth and SSD = 80 cm were measured along the robotic x axis and y axis for the cylindrical collimators of the CyberKnife (diameter 60, 50, 40, 30, 20, 15, 12.5, 10, 7.5 and 5mm). To determine the output factors the dose profile was measured at 0.1 mm steps around the field center to find the maximum dose value. The liquid chamber array (1000SRS) measurement was performed with the same setup, but with RW3 buildup. Results: The 1000SRS measurements closely conform with the TM60019 profile measurement in all profile regions and for all collimator sizes. The profile measurement is influenced by the almost equal spatial resolution of the TM60019 detector (radius of the sensitive area 1.1mm) and of the 1000SRS liquid chamber array (single chamber width 2.3mm). The measured dose profiles have not been corrected for this limited spatial resolution. Rather we purpose to consider that spatial dose averaging over 2 mm wide regions might be justified in view of patient positioning inaccuracies and of the spaces in tissue participating in the biological radiation responses. Conclusion: The 1000SRS data points conform with the TM60019 profile measurements at all profile regions showing the applicability of liquid ion chamber arrays with the CyberKnife system.

60 APPLIED LIFE SCIENCES↗

SU-E-J-191: Motion Prediction Using Extreme Learning Machine in Image Guided Radiotherapy

Purpose: Real-time motion tracking is a critical issue in image guided radiotherapy due to the time latency caused by image processing and system response. It is of great necessity to fast and accurately predict the future position of the respiratory motion and the tumor location. Methods: The prediction of respiratory position was done based on the positioning and tracking module in ARTS-IGRT system which was developed by FDS Team (www.fds.org.cn). An approach involving with the extreme learning machine (ELM) was adopted to predict the future respiratory position as well as the tumor’s location by training the past trajectories. For the training process, a feed-forward neural network with one single hidden layer was used for the learning. First, the number of hidden nodes was figured out for the single layered feed forward network (SLFN). Then the input weights and hidden layer biases of the SLFN were randomly assigned to calculate the hidden neuron output matrix. Finally, the predicted movement were obtained by applying the output weights and compared with the actual movement. Breathing movement acquired from the external infrared markers was used to test the prediction accuracy. And the implanted marker movement for the prostate cancer was used to test the implementation of the tumor motion prediction. Results: The accuracy of the predicted motion and the actual motion was tested. Five volunteers with different breathing patterns were tested. The average prediction time was 0.281s. And the standard deviation of prediction accuracy was 0.002 for the respiratory motion and 0.001 for the tumor motion. Conclusion: The extreme learning machine method can provide an accurate and fast prediction of the respiratory motion and the tumor location and therefore can meet the requirements of real-time tumor-tracking in image guided radiotherapy.

60 APPLIED LIFE SCIENCES↗

THE UVJ SELECTION OF QUIESCENT AND STAR-FORMING GALAXIES: SEPARATING EARLY- AND LATE-TYPE GALAXIES AND ISOLATING EDGE-ON SPIRALS

We utilize for the first time Hubble Space Telescope Advanced Camera for Surveys imaging to examine the structural properties of galaxies in the rest-frame U - V versus V - J diagram (i.e., the UVJ diagram) using a sample at 0.6 < z < 0.9 that reaches a low stellar mass limit (log M/M{sub Sun} >10.25). The use of the UVJ diagram as a tool to distinguish quiescent galaxies from star-forming galaxies (SFGs) is becoming more common due to its ability to separate red quiescent galaxies from reddened SFGs. Quiescent galaxies occupy a small and distinct region of UVJ color space and we find most of them to have concentrated profiles with high Sersic indices (n > 2.5) and smooth structure characteristic of early-type systems. SFGs populate a broad but well-defined sequence of UVJ colors and are comprised of objects with a mix of Sersic indices. Interestingly, most UVJ-selected SFGs with high Sersic indices also display structure due to dust and star formation typical of the n < 2.5 SFGs and late-type systems. Finally, we find that the position of an SFG on the sequence of UVJ colors is determined to a large degree by the mass of the galaxy and its inclination. Systems that are closer to edge-on generally display redder colors and lower [O II]{lambda}3727 luminosity per unit mass as a consequence of the reddening due to dust within the disks. We conclude that the two main features seen in UVJ color space correspond closely to the traditional morphological classes of early- and late-type galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗