Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power system control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Controls for Electrified Aircraft Propulsion

Advanced electrified aircraft propulsion (EAP) concepts with integrated power, propulsion, and thermal systems require the development of equally sophisticated controllers to fly safe and efficient missions. Hybrid electric aircraft utilize electric machines mechanically coupled to the engine shafts to extract and insert power for a variety of purposes. Additionally, electric machines may drive propulsive fans pulling from a combination of on-board energy storage devices and engine extracted power. NASA’s investment in hybrid electric aircraft hardware-in-the-loop testing enables controls research on representative engine models using a novel emulation and scaling methodology. High-voltage, high-power electrical powertrain presents several technical risks at altitude. High-power requires high efficiency to minimize losses. Superconducting electric machines and power distribution research at NASA has identified key challenges with potential controls solutions. These risks necessitate the development of controllers robust to model uncertainty, disturbances, and fault conditions. System health management and fault detection schemes play an important role in a multi-layer controls approach that utilizes a supervisor which oversees inner loops for the highly coupled power, propulsion, and thermal systems. Such a supervisory controller enables coordinates energy transfer between engines, energy storage devices, electric machines, propulsors, and heat exchangers. Existing methods have shown an improvement in engine operability using the hybrid electric powertrain.

Halle E Buescher↗

Experimental Comparison of PV-Smoothing Controllers using Distributed Generators

The power output variability of photovoltaic systems can affect local electrical grids in locations with high renewable energy penetrations or weak distribution or transmission systems. In those rare cases, quick controllable generators (e.g., energy storage systems) or loads can counteract the destabilizing effects by compensating for the power fluctuations. Previously, control algorithms for coordinated and uncoordinated operation of a small natural gas engine-generator (genset) and a battery for smoothing PV plant output were optimized using MATLAB/Simulink simulations. The simulations demonstrated that a traditional generation resource such as a natural gas genset in combination with a battery would smooth the photovoltaic output while using a smaller battery state of charge (SOC) range and extending the life of the battery. This paper reports on the experimental implementation of the coordinated and uncoordinated controllers to verify the simulations and determine the differences in the controllers. The experiments were performed with the PNM PV and energy storage Prosperity site and a gas engine-generator located at the Aperture Center at Mesa Del Sol in Albuquerque, New Mexico. Two field demonstrations were performed to compare the different PV smoothing control algorithms: (1) implementing the coordinated and uncoordinated controls while switching off a subsection of the PV array at precise times on successive clear days, and (2) comparing the results of the battery and genset outputs for the coordinated control on a high variability day with simulations of the coordinated and uncoordinated controls. It was found that for certain PV power profiles the SOC range of the battery may be larger with the coordinated control, but the total amp-hours through the battery-which approximates battery wear-will always be smaller with the coordinated control.

14 SOLAR ENERGY↗

A Data-Driven Algorithm for Enabling Delay Tolerance in Resilient Microgrid Controls Using Dynamic Mode Decomposition

The increased implementation of smart grid technologies in the power distribution grid presents unique opportunities that enable resiliency, but also brings challenges motivating needs for novel solutions and mitigation techniques. The bi-directional power and data flow allow for the grid to operate with increased resiliency, which is the ability to avoid discontinuity of service to end-use loads during extreme events. However, in applications where control of the distribution grid or microgrid relies on communication networks, the degradation of communication systems in the form of loss or high latency can cause maloperation and result in loss of end-use loads. Here this paper presents a novel framework to enable delay tolerance of centralized microgrid control schemes to mitigate communication system latency impacts and guarantee successful control action. We demonstrate the delay tolerance on a control scheme that operates a battery energy storage system (BESS) to offset the sudden loss of generation and maintain system frequency. During periods of severely degraded communication system performance, the proposed delay-tolerant algorithm compensates for the latency by utilizing a data-driven model generated at the device level using dynamic mode decomposition (DMD) to determine the performance of the communications. The DMD technique predicts the system’s frequency using device-level terminal measurements and provides updated control signals. The HELICS cosimulation platform evaluates the cyber-physical interaction of the power system model in GridLAB-D, the centralized control agent in Python, and the discrete network model in NS-3. The framework is tested and validated on the IEEE-123 node system modified to represent a networked remote microgrid model, and the results show an improvement in the dynamic performance

24 POWER TRANSMISSION AND DISTRIBUTION↗

A thruster sub-system module /TSSM/ for solar electric propulsion

The thruster subsystem module (TSSM) considered for solar electric propulsion (SEP) missions is to consist of a 30-cm ion thruster, a thruster gimbal system, a propellant storage and feed system, a power processing unit, a modular thermal control system, and a modular support structure. TSSM design requirements are considered along with a TSSM general design approach. It is pointed out that a TSSM for SEP missions can be designed and built based on existing technology.

Sharp, G. R.↗

The Mars 2020 Perseverance Navigation Filter

The Mars 2020 (M2020) Entry Descent and Landing (EDL) system delivered a rover named “Perseverance” at Jezero crater (Mars) on February 18th, 2021. M2020 EDL used a Guidance Navigation and Control (GN&C) system to achieve its landing target objectives. The navigation filter (NavFilter) integrated Descent Inertial Measurement Unit (DIMU) measurements to estimate position and attitude. The NavFilter also used the Terminal Descent Sensor (TDS) to es-timate surface-relative position and velocity corrections. The NavFilter provided all of the dynamic state information to the entry controller, entry guidance, Lander Vision System (LVS) and powered descent guidance and control algo-rithms. The NavFilter for Perseverance is based on Curiosity’s NavFilter with a couple of modifications.

Casoliva, Jordi↗

Cyber Security of the Electric Power Grid

Economic security and quality of life in modern society depend on the reliable supply and delivery of electric power. New cyber security vulnerabilities are emerging that introduce new risks to the Nation’s electric power grid. This presentation will describe issues, trends, and research opportunities for enhancing the cyber security of control systems associated with electric power system operations.

computer security↗

Adaptive Load Shedding for Grid Emergency Control via Deep Reinforcement Learning

Emergency control, typically such as under-voltage load shedding (UVLS), is broadly used to grapple with low voltage and voltage instability issues in real-world power systems under contingencies. However, existing emergency control schemes are rule-based and cannot be adaptively applied to uncertain and floating operating conditions. Here, we propose an adaptive UVLS algorithm for emergency control via deep reinforcement learning (DRL) and expert systems. We first construct dynamic components for picturing the power system operation as the environment. The transient voltage recovery criteria, which poses time-varying requirements to UVLS, is integrated into the states and reward function to advise the learning of deep neural networks. The proposed method has no tuning issue of coefficients in reward functions, and this issue was regarded as a deficiency in the existing DRL-based algorithms. Case studies illustrate that the proposed method outperforms the traditional UVLS relay in both the timeliness and efficacy for emergency control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

sCO2 Primary Power Large-Scale Pilot Plant FEED Summary

Echogen Power Systems and its project partners the Electric Power Research Institute, CDM Smith, Riley Power Inc. (a Babcock Power Inc. company), and the University of Missouri completed the Front-End Engineering Design (FEED) study of a nominal 10 MWe supercritical carbon dioxide (sCO2) large-scale pilot plant based on Recompression Brayton Cycle (RCBC) architecture. The FEED study was completed under Phase II of the U.S. Department of Energy Fossil Fuel Large-Scale Pilots program. The FEED study scope included the preliminary design of the combustion and environmental control systems, the primary heater, the sCO2 power cycle and its associated turbomachinery, and the balance of plant equipment to determine accurate cost and schedule requirements for fabrication and installation of the system at the University of Missouri’s Combined Cooling, Heat, and Power Plant, located in Columbia, Missouri. The RCBC sCO2 cycle presents superior thermodynamic efficiency compared to steam-Rankine cycles and is adaptable to a broad range of heat sources. The risk aversion of the power generation industry requires a successful large-scale pilot plant demonstration to enable financing and deployment of commercial-scale plants. Therefore, successful construction and demonstration of a 10 MWe RCBC sCO2 power plant would empower a transformational step forward for the efficiency of the next generation of utility power plants. This paper provides details on the primary heater, environmental control systems, and sCO2 power cycle design and performance.

01 COAL, LIGNITE, AND PEAT↗

Positive-Sequence Modeling of Droop-Controlled Grid-Forming Inverters for Transient Stability Simulation of Transmission Systems

Here, this paper describes a positive-sequence model to represent two widely reported droop-controlled grid-forming inverters for bulk power systems simulation study. Methods of how to develop the equivalent voltage source behind impedance to represent inverters with and without inner control loops, modeling of P-f and Q-V droop controls, active and reactive power limiting modeling, and modeling of fault current limiting controls are described in detail. The model is implemented in commercially available positive-sequence simulation tools and compared with detailed electromagnetic transient models in both a single-grid-forming-inverter infinite-bus system and a modified IEEE 39-bus system. Finally, the model is tested on the full US Western Electricity Coordinating Council (WECC) system. Study results show that the model has a good level of accuracy compared to the detailed EMT models, and at the same time also achieves a high computational efficiency, which is suitable for the bulk power system simulation study.

42 ENGINEERING↗

MPC-based double-layer real-time conditional cSelf-restoration for interconnected microgrids

In this report, we propose a novel model predictive control(MPC)-based real-time conditional self-restoration energy management system (CSR-EMS) for interconnected microgrids (IMGs) integrated with renewable energy sources (RESs) and energy storage systems (ESSs). Superior to the existing IMG self-restoration methods, the “conditionality” of the proposed CSR-EMS can economically realize self-restoration and grid-assisted restoration during energy deficiency or faults, in both islanded and grid-connected modes. Cost minimization is implemented as the objective function to judge in real-time which restoration mode is economically preferred. The proposed CSR-EMS comprises two layers–the lower layer operates locally to eliminate electricity fluctuations created by RESs and ensure economic effectiveness within an MG, whereas the upper layer oversees the real-time operational status of the IMG system and determines power exchange among microgrids (MGs) during abnormalities. In detail, when a microgrid inside the IMG system experiences an energy deficiency, the CSR-EMS, on an MPC basis, intelligently optimizes power production from each dispatchable distributed generator (DG), ESS, power imported from the main grid, and power exchange among the IMGs to maintain the demand–supply balance, while considering system recovery cost, state of charge (SoC) of ESSs and operation modes of the IMGs (i.e., grid-connected or islanded mode). Simulation results and comparisons with existing IMG self-healing EMSs demonstrate the economic efficacy of the proposed CSR-EMS strategy during normal and abnormal operations, which can be used as an energy control framework for modern power systems with multiple interconnected microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Propulsion Component Test Capabilities at MSFC’s Test Stand 115

Marshall Space Flight Center’s Test Stand 115 (TS115) is a propulsion component test facility in operation since its original activation in 1964 for testing small to medium size liquid rocket engine components including injectors, channel-cooled chambers, nozzles, passively-cooled metallic and composite nozzle extensions, valves, turbomachinery, and igniters. TS115 is a "blowdown" type facility, using high pressure tankage and components to provide liquid, gaseous, and cryogenic fluid delivery at specified pressures and flowrates. The facility consists of an open steel test stand structure, a mechanical hardware preparation shop, an electrical support equipment building, a control room, and a centralized data system room. In general, the facility infrastructure is rated to 3,000 psig. TS115 can accommodate thrust levels up to 10,000 lbf in the horizontal position. The facility is actively used for various internal NASA test programs as well as test campaigns for external customers from other government agencies, commercial industry partners, and academia. The available fluid systems, electrical power and instrumentation capabilities, facility controls and data acquisition systems, test program support capabilities, and available test rig configurations for external customer use are discussed in this paper.

Tal Wammen↗

Integrated Power/Attitude Control System (IPACS)

During orbit day, solar energy collected by the solar cell arrays and transformed into electrical energy is used to power the spacecraft subsystems, including the control system. In conventional spacecraft designs, a portion of the energy collected during the light portion of the orbit is stored in a set of batteries for use during orbit night. In the Integrated Power/Attitude Control System (IPACS) approach, that energy is stored in the rotating flywheel in the form of kinetic energy. Umbra electrical power demands are satisfied by attaching a generator to the wheel shaft and despinning the rotor. Through this approach, the battery system is no longer required and thus is eliminated.

Keckler, C. R.↗

Blockchain Enabled Intelligence of Federated Systems (BELIEFS): An attack-tolerant trustable distributed intelligence paradigm

In this article, a Blockchain Enabled Intelligence of Federated Systems (BELIEFS) is proposed to conduct cooperative control for the multi-regional large-scale power system with a multi-agents system (MAS). By establishing a two levels blockchain, each regional AI agent can simultaneously manage intra-regional controllers and cooperate with other AI agents. Under the consensus mechanism, the agents, which respectively conducted distributed deep reinforcement learning (DDRL) algorithm in multi-regions, can have the tolerant capability of malicious attacks in their training process. The demonstration of the proposed approach is within a multi-regional large-scale interconnected power system. Under the mode of "centralized dispatching and hierarchical management", this article aims to definite a mathematical model to deal with the control problem of the power systems. With the comparison experiments, the effectiveness and efficiency of our proposed method in the training process are verified. In addition, malicious attacks are set on the main chain and shard chains to verify the attack-tolerant capability. We expect that such approach and results can suggest a new paradigm of attack-tolerant trustable distributed AI deployment.

97 MATHEMATICS AND COMPUTING↗

Guarantee Testing Results from the Greenidge Mult-Pollutant Control Project

CONSOL Energy Inc. Research & Development (CONSOL R&D) performed flue gas sampling at AES Greenidge to verify the performance of the multi-pollutant control system recently installed by Babcock Power Environmental Inc. (BPEI) on the 107-megawatt (MW) Unit 4 (Boiler 6). The multi-pollutant control system includes combustion modifications and a hybrid selective non-catalytic reduction (SNCR)/induct selective catalytic reduction (SCR) system to reduce NO{sub x} emissions, followed by a Turbosorp{reg_sign} circulating fluidized bed dry scrubber system and baghouse to reduce emissions of SO{sub 2}, SO{sub 3}, HCl, HF, and particulate matter. Mercury removal is provided via the co-benefits afforded by the in-duct SCR, dry scrubber, and baghouse and by injection of activated carbon upstream of the scrubber, as required. Testing was conducted through ports located at the inlet and outlet of the SCR reactor to evaluate the performance of the hybrid NO{sub x} control system, as well as through ports located at the air heater outlet and baghouse outlet or stack to determine pollutant removal efficiencies across the Turbosorp{reg_sign} scrubber and baghouse. Data from the unit's stack continuous emission monitor (CEM) were also used for determining attainment of the performance targets for NO{sub x} emissions and SO{sub 2} removal efficiency.

54 ENVIRONMENTAL SCIENCES↗

Design and Control of a Ship Motion Simulation Platform from an Energy Efficiency Perspective

Most hydraulic servo systems are designed with little consideration for energy efficiency. Pumps are selected based upon required peak power demands, valves are chosen primarily for their rated flow, actuators for the maximum force. However, the design of a hydraulic servo system has great potential in terms of energy efficiency that has, for the most part, been ignored. This paper describes the design and control of a large-scale ship motion simulation platform that was designed and built at Oak Ridge National Laboratory for the Office of Naval Research. The primary reasons to incorporate energy-efficiency features into the design are cost and size reduction. A preliminary survey of proposed designs based on traditional motion simulation platform configurations (Stuart Platforms) required hydraulic power supplies approaching 1.22 MW. This manuscript describes the combined design and control effort that led to a system with the same performance requirements, however requiring a primary power supply that was less than 112 kW. The objective of this paper is to illustrate alternative design and control approaches that can significantly reduce the power requirements of hydraulic systems and improve the overall energy-efficiency of large-scale hydraulically actuated systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ramping Performance Analysis of the Kahuku Wind-Energy Battery Storage System

High penetrations of wind power on the electrical grid can introduce technical challenges caused by resource variability. Such variability can have undesirable effects on the frequency, voltage, and transient stability of the grid. Energy storage devices can be an effective tool in reducing variability impacts on the power grid in the form of power smoothing and ramp control. Integrating anenergy storage system with a wind power plant can help smooth the variable power produced from wind. This paper explores the fast-response, megawatt-scale, wind-energy battery storage systems that were recently deployed throughout the Hawaiian islands to support wind and solar projects.

17 WIND ENERGY↗

A Review of Transformer Aging and Control Strategies

Transformer aging is an important challenge in power system. Distribution transformers themselves are minimally controllable, but smart meters provide excellent, new insights into electrical loads, which insights can be used to understand and mitigate transformer aging. The nature of transformer loads is changing with the integration of distributed energy resources (DERs) and electric vehicles (EVs). This paper first reviews factors that influence the aging of distribution transformers, including root causes of transformer failure. Existing and proposed load control methods are then discussed. A distribution model is introduced to help evaluate potential control methods.

Gourisetti, Sri Nikhil Gup↗

The application of hydraulics in the 2,000 kW wind turbine generator

A 2000 kW turbine generator using hydraulic power in two of its control systems is being built under the management of NASA Lewis Research Center. The hydraulic systems providing the control torques and forces for the yaw and blade pitch control systems are discussed. The yaw-drive-system hydraulic supply provides the power for positioning the nacelle so that the rotary axis is kept in line with the direction of the prevailing wind, as well as pressure to the yaw and high speed shaft brakes. The pitch-change-mechanism hydraulic system provides the actuation to the pitch change mechanism and permits feathering of the blades during an emergency situation. It operates in conjunction with the overall windmill computer system, with the feather control permitting slewing control flow to pass from the servo valve to the actuators without restriction.

Onufreiczuk, S.↗