Search NASA⌕ Search

SEARCH · Search NASA

Results for “Process Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Scalable Synthesis and Multi-Electron Transfer of Aniline/Fluorene Copolymer for Solution-Processable Battery Cathodes

Here, the authors report the highly efficient, multigram-scale synthesis of an ester-functionalized, poly(aniline-co-fluorene) polymer. The excellent solubility and film-forming ability of this polymer facilitate its application as a reversible battery cathode. Electrochemical quartz crystal microbalance with dissipation monitoring confirms a multi-electron transfer process, resulting in a specific discharge capacity of 51 mAh g -1 and a high reversible doping level of 0.69. Galvanostatic cycling at 1 C demonstrates excellent electrode stability with a capacity retention of 95.2% after 100 cycles. Therefore, this work demonstrates a novel electroactive polymer that exemplifies how chemical functionality may be used to properly balance processability and electroactivity of macromolecular battery cathodes.

25 ENERGY STORAGE↗

Investigating relationship between surface topography and emissivity of metallic additively manufactured parts

Due to the direct relationship between thermal history and mechanical behavior, in situ thermal monitoring is key in gauging quality of parts produced with additive manufacturing (AM). Accurate monitoring of temperatures in an AM process requires knowledge of environment and object parameters including object emissivity. The emissivity is dependent on several variables, including: wavelength, material composition, temperature, and surface topography. Researchers have been concerned with the thermal emissivity dependence on temperature since large ranges are seen in metal powder bed processes, but there is also an extensive range of surfaces produced by AM. This work focused on discovering what roughness characteristics control thermal emissivity through investigation of prototypic 316 stainless steel AM samples produced with a range of build conditions on a laser powder bed fusion machine. Through experimental measurements of emissivity using hemispherical directional reflectance (HDR), guided by simulations using a finite-difference time-domain (FDTD) Maxwell solver, it was found that combinations of existing roughness parameters describing both height and slope of the surface correlate well with emissivity changes. Furthermore, these parameters work well due to their apt description of surface features encouraging internal reflection, which is the phenomenon that increases emissivity when a surface falls under the geometric optical region conditions.

36 MATERIALS SCIENCE↗

SU-E-I-27: Establishing Target Exposure Index Values for Computed Radiography

Purpose: To develop a standard set of target exposure index (TEI) values to be applied to Agfa Computed Radiography (CR) readers in accordance with International Electrotechnical Committee 62494-1 (ed. 1.0). Methods: A large data cohort was collected from six USAF Medical Treatment Facilities that exclusively use Agfa CR Readers. Dose monitoring statistics were collected from each reader. The data was analyzed based on anatomic region, view, and processing speed class. The Agfa specific exposure metric, logarithmic mean (LGM), was converted to exposure index (EI) for each data set. The optimum TEI value was determined by minimizing the number of studies that fell outside the acceptable deviation index (DI) range of +/− 2 for phototimed techniques or a range of +/−3 for fixed techniques. An anthropomorphic radiographic phantom was used to corroborate the TEI recommendations. Images were acquired of several anatomic regions and views using standard techniques. The images were then evaluated by two radiologists as either acceptable or unacceptable. The acceptable image with the lowest exposure and EI value was compared to the recommended TEI values using a passing DI range. Results: Target EI values were determined for a comprehensive list of anatomic regions and views. Conclusion: Target EI values must be established on each CR unit in order to provide a positive feedback system for the technologist. This system will serve as a mechanism to prevent under or overexposures of patients. The TEI recommendations are a first attempt at a large scale process improvement with the goal of setting reasonable and standardized TEI values. The implementation and effectiveness of the recommended TEI values should be monitored and adjustments made as necessary.

60 APPLIED LIFE SCIENCES↗

The Development of Legacy Waste Scaling Factors for Radioactively Contaminated Soils at Chalk River Laboratories - 19333

The Chalk River Laboratories (CRL) began nuclear operations in 1947. Beginning in 1952 after the NRX accident, the management of excess contaminated liquids from the accident, and later in 1953, other waste liquids, were intermittently dispersed to trenches and pits in the local sand. The local sands proved effective at immobilization of actinides, and most activation and fission products. However there was very limited retention of some more commonly mobile radionuclides. Sand filtration performance and radionuclide migration was studied beginning in 1952. Monitoring data indicated slow migration of most radioactive contaminants away from the trenches and pits due to the adsorbing capacity of the sand substrate. The radionuclide migration continues to be studied today in frequent plume monitoring studies. Because many hard-to measure (HTM) radionuclides may also present as long term dose contributors in post remediation scenarios, or in disposal site performance assessments, the quantification of these HTM radionuclides is important. The use of scaling factors between HTM radionuclides and easy-to-measure (ETM) radionuclides (gamma emitters) for packaged soil wastes would alleviate significant effort in sampling individual waste containers. As part of plume monitoring studies and the environmental remediation process, significant characterization of soils have been performed at the site. The soil sample data from multiple historic waste management areas across site is combined and relationships between HTM radionuclides and ETM or key radionuclides are examined. Additional (secondary) relationships between ETM key nuclides are also explored to evaluate secondary scaling relationships between ETM key radionuclides (e.g., Co- 60/Cs-137), because of the significant decay of the activation product key radionuclide Co-60, (predominantly 10-20 half-lives). The evaluation is yielding consistent scaling factors for legacy soil wastes in the historic waste management areas. Given the hydrogeology of the site, a sandy shallow unconfined aquifer, and the annual precipitation of about 0.85 m/a, this evaluation reveals some expected relationships between fission products and actinides and some unanticipated relationships between more mobile radionuclides and key gamma emitters. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

IDC Re-Engineering Phase 2 System Requirements Document V1.3.

This System Requirements Document (SRD) defines waveform data processing requirements for the International Data Centre (IDC) of the Comprehensive Nuclear Test Ban Treaty Organization (CTBTO). The IDC applies, on a routine basis, automatic processing methods and interactive analysis to raw International Monitoring System (IMS) data in order to produce, archive, and distribute standard IDC products on behalf of all States Parties. The routine processing includes characterization of events with the objective of screening out events considered to be consistent with natural phenomena or non-nuclear, man-made phenomena. This document does not address requirements concerning acquisition, processing and analysis of radionuclide data but includes requirements for the dissemination of radionuclide data and products.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Elevated Temperature Alpha Spectroscopy with Nickel-Platinum {sup 4}H-SiC Schottky Diodes

In order to protect against the diversion of special nuclear material during pyro-processing of spent nuclear fuel, an online monitoring of the actinide concentrations must be developed. In order to do so, alpha spectroscopy can be employed in order to determine the relative concentrations of various isotopes based on the characteristic alpha spectrum of each isotope of interest. The operating temperatures in the pyro-processing environment are such that high temperature operability of alpha detectors is required. The Idaho National Laboratory (INL) electro-refiner operates at a molten salt temperature of approximately 500 deg. C. The vapor temperature above the molten salt is approximately 100 deg. C. In order to provide reasonably compact online monitoring of the actinide concentrations within the molten salt the detector would be located in this vapor region. The temperature in this location is too high for a commercial silicon detector to operate without serious signal degradation due to thermal noise. As the operating temperature increases, the thermal energy available to the charge carriers within the semiconductor increases. For narrow band-gap semiconductors like silicon, this increase in free charge carriers with increasing temperature leads to unacceptable leakage current at relatively low temperatures when compared with wide band-gap materials. In order to overcome this, a wide band-gap material is employed. An alpha particle sensor utilizing a nickel Schottky barrier {sup 4}HSiC wafer was heated to a temperature of 100 deg. C and an alpha spectrum collected. The performance of the sensor at 100 deg. C was compared to the room temperature performance. Molten salts such as those used in the INL electro-refiner exhibit strong corrosive properties. Any sensor which will be exposed to or submerged in the molten salt must have a ruggedized sensor face capable to withstand the corrosive environment. In the contact design utilized in this paper the Schottky barrier forming metal, nickel, is coated with a thin layer of platinum to serve as a corrosion resistant layer. An additional modification to previous designs was the simplification of the Schottky barrier composition. A Schottky barrier is created when a metal is brought into close physical contact with a semiconductor. To first order, the barrier height of the Schottky barrier is a result of the mismatch between the electron affinity of the semiconductor and the metal work function of the metal. In previous iterations, the high temperature performance of the detectors had been limited by diffusion processes between the various metal layers. In order to reduce the likelihood of such a degradation, the Schottky contact structure was simplified without loss of functionality. By replacing the multiple metal layers with a nickel Schottky forming layer capped with a thin platinum layer, the potential degradation of the Schottky barrier height could be reduced, primarily through the similar Schottky barrier height to nickel formed by platinum with SiC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

135 Xe measurements with a two-element CZT-based radioxenon detector for nuclear explosion monitoring

Measurement of elevated concentrations of xenon radioisotopes ( 131m Xe, 133m Xe, 133 Xe and 135 Xe) in the atmosphere has been shown to be a very powerful method for verifying whether or not a detected explosion is nuclear in nature. These isotopes are among the few with enough mobility and with half-lives long enough to make their detection at long distances realistic. Existing radioxenon detection systems used by the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) suffer from problems such as complexity, need for high maintenance and memory effect. To study the response of CdZnTe (CZT) detectors to xenon radioisotopes and investigate whether it is capable of mitigating the afore-mentioned issues with the current radioxenon detection systems, a prototype detector utilizing two coplanar CZT detectors was built and tested at Oregon State University. The detection system measures xenon radioisotopes through beta-gamma coincidence technique by detecting coincidence events be-tween the two detectors. Here in this paper, we introduce the detector design and report our measurement results with radioactive lab sources and 135 Xe produced in the OSU TRIGA reactor. Minimum Detectable Concentration (MDC) for 135 Xe was calculated to be 1.47 ± 0.05 mBq/m 3 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-F-18A-01: Preliminary Results of a Prototype Quality Control Process for Spectral CT

Purpose: A prototype quality control (QC) phantom and analysis process has been designed specifically to monitor dual-energy CT and address the current lack of quantitative oversight of the spectral capabilities of these scanners. Methods: A prototype solid water phantom was designed with multiple material inserts, and to support both head and body protocols. Inserts included tissue equivalent and material rods (iodine, iron, calcium) at various concentrations. The oval body phantom, measuring 30cm×40cm×15cm, was scanned using four dual-energy protocols with CTDIvol ranges of 19.6–62mGy (0.516 pitch) and 10.3–32.5mGy (0.984 pitch), and rotation times ranging from 0.5-1sec. The circular head phantom, measuring 22cm in diameter by 15cm, was scanned using three dual-energy protocols with CTDIvol ranges of 67–132.6mGy (0.531 pitch) and 36.7–72.7mGy (0.969 pitch), and rotation times ranging from 0.5–0.9sec. All images were reconstructed at 50, 70, 110 and 140 keV, and using a water-iodine material basis pair. The images were evaluated for iodine quantification accuracy and stability of monoenergetic reconstructions. The phantom was scanned twice on ten GE 750HD CT scanners to evaluate inter-scanner agreement, as well as ten times on a single scanner over a oneweek period to evaluate intra-scanner repeatability. Results: Preliminary analysis revealed consistent (inter- and intra-scanner) iodine quantification accuracy within 10% was only achieved for protocols in the upper half of dose levels assessed when grouped by pitch. Although all scanners undergo rigorous daily single-energy QC, iodine quantification accuracy from one scanner unexpectedly deviated from the other nine substantially. In general, inter-scanner agreement and intra-scanner repeatability varied with dose, rotation time and reconstructed keV. Conclusion: Preliminary results indicate the need for a dual-energy QC process to ensure inter-scanner agreement and intra-scanner repeatability. In particular, iodine quantification accuracy within 10% may not be achievable using lower dose techniques. Future plans include longer term dual-energy CT QC data collection. In-kind financial support was provided by GE Healthcare.

60 APPLIED LIFE SCIENCES↗

Stability of a Uranium-Contaminated Plume in a Karst Aquifer in Northwest New Mexico - 19574

The US Department of Energy (DOE) Office of Legacy Management monitors groundwater contamination resulting from ore processing operations conducted between 1953 and 1982 at a former uranium mill site on property that is now part of the Bluewater, New Mexico, Disposal Site. The site is located in the Grants Mineral Belt in northwest New Mexico at the base of the Zuni Mountains. It is estimated that prior to mill tailings encapsulation in 1995, approximately 21.6 billion liters (5.7 billion gallons) of tailings fluid seeped from the main tailings impoundment into the underlying aquifers. Today, there is remnant groundwater contamination from the mill in two aquifers: the San Andres-Glorieta (SAG) bedrock aquifer and the Ancestral Rio San Jose alluvial aquifer. Groundwater contamination in the SAG aquifer is of particular concern, as the aquifer is the primary water source in the region for municipal, agricultural, and industrial use. Municipal wells for the region are located as close as 6.4 kilometers (4 miles) southeast of the Main Tailings Disposal Cell. The SAG uranium plume extends east for more than 4.8 kilometers (3 miles) beyond the site's eastern boundary, along the direction of groundwater flow. The plume intersects the Homestake Mining Company site, another former uranium mill site undergoing active remediation. The SAG aquifer contains two formations, the Lower Permian San Andres Limestone and the Glorieta Sandstone. Most of the groundwater moving through the SAG aquifer is in ancient karst features consisting of open conduits where the limestone has dissolved, resulting in flow through solution cavities, solution channels, cavernous zones, and enlarged fracture openings. These features make the San Andres Limestone extremely permeable and capable of rapidly transporting groundwater. In addition, the karst characteristics make the aquifer difficult to evaluate and the uranium plume difficult to characterize. Numerous faults in the area, including two directly under the Main Tailings Disposal Cell, further complicate characterization by impacting groundwater flow both onsite and in the vicinity. A DOE study of the SAG aquifer uranium plume at the Bluewater site, conducted in 2014, indicated that the plume had moved offsite soon after the start of milling and effectively stabilized in its present location prior to the 1980's. An updated study completed in 2018 confirmed previous information regarding general plume stability and provided insight regarding potential localized trends east and south of the Main Tailings Disposal Cell. One such trend may be decreasing uranium concentrations east of the Main Tailings Disposal Cell, potentially attributable to regional groundwater elevation decreases. Both the 2013 and 2017 plumes suggest that the dissolved uranium contamination is derived from the leaching of a secondary mineralized zone derived from seeped tailings fluids in the geologic formations and fault zones below the Main Tailings Disposal Cell at the Bluewater site. In developing the 2013 and 2017 SAG aquifer uranium plume depictions, DOE had to address challenges associated with data quality and comparability. Analytical results used to determine the plume extent were compiled from multiple sources, including the state of New Mexico, Homestake Mining Company, and DOE. Each source used different well identifiers and coordinate systems, and well information between sources was inconsistent. Also, the integrity of some wells was questionable and necessitated review; casing integrity was found to be compromised in multiple wells. Given these uncertainties, some of these wells were excluded from the characterization. Another source of uncertainty is the paucity of wells, particularly monitoring wells, near or immediately downgradient of the leading edge of the plume. Therefore, the exact extent of the SAG aquifer uranium plume is not known at this time. There is, however, no evidence or indication of milling-related contamination in municipal wells. Furthermore, due to plume stability and direction of groundwater flow, the municipal wells are not expected to be impacted. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

EMP, Attachment 2: Data Management Plan

This Data Management Plan (DMP) is an attachment to the Pacific Northwest National Laboratory Environmental Radiological Air Monitoring Plan (EMP). PNNL is a U.S. Department of Energy Office of Science national laboratory. Radioactive effluent monitoring and environmental surveillance for PNNL operations in Washington State are the responsibility of the PNNL Environmental Protection and Regulatory Programs division and are conducted by the Environmental Radiation Task staff. This DMP describes the data management processes for PNNL radioactive air emissions (stack) monitoring and environmental radiological ambient air surveillance activities.

40 CFR 61 Subpart H↗

Development of pulse laser processing for mounting fiber Bragg grating

Pulse laser processing has been developed for the application of industrial plants in monitoring and maintenance. Surface cleaning by nano-second laser ablation was demonstrated for decontamination of oxide layers of Cr contained steel. Direct writing by femtosecond processing induced a Bragg grating in optical fiber to make it a seismic sensor for structural health monitoring. Adhesive cement was used to fix the seismic sensor on the surface of reactor coolant pipe material. Pulse laser processing and its related technologies were presented to overcome the severe accidents of nuclear power plants.

36 MATERIALS SCIENCE↗

Real time intelligent process control system for thin film solar cell manufacturing

This project addresses the problem of lower solar conversion efficiency and waste in the typical solar cell manufacturing process. The work from the proposed development will lead toward developing a system which should be able to increase solar panel conversion efficiency by an additional 12-15% resulting in lower cost panels, increased solar technology adoption, reduced carbon emissions and reduced dependency on foreign oil. All solar cell manufacturing processes today suffer from manufacturing inefficiencies that currently lead to lower product quality and lower conversion efficiency, increased product cost and greater material and energy consumption. This results in slower solar energy adoption and extends the time solar cells will reach grid parity with traditional energy sources. The thin film solar panel manufacturers struggle on a daily basis with the problem of thin film thickness non-uniformity and other parameters variances over the deposited substrates, which significantly degrade their manufacturing yield and quality. Optical monitoring of the thin films during the process of the film deposition is widely perceived as a necessary step towards resolving the non-uniformity and non-homogeneity problem. In order to enable the development of an optical control system for solar cell manufacturing, a new type of low cost optical sensor is needed, able to acquire local information about the panel under deposition and measure its local characteristics, including the light scattering in very close proximity to the surface of the film. This information cannot be obtained by monitoring from outside the deposition chamber (as traditional monitoring systems do) due to the significant signal attenuation and loss of its scattering component before the reflected beam reaches the detector. In addition, it would be too costly to install traditional external in-situ monitoring systems to perform any real-time monitoring over large solar panels, since it would require significant equipment refurbishing needed for installation of multiple separate ellipsometric systems, and development of customized software to control all of them simultaneously. The proposed optical monitoring system comprises AccuStrata’s fiber optics sensors installed inside the thin film deposition equipment, a hardware module of different components (beyond the scope of this project) and our software program with iterative predicting capability able to control material bandgap and surface roughness as films are deposited. Our miniature fiber optics monitoring sensors are installed inside the vacuum chamber compartments in very close proximity where the independent layers are deposited (an option patented by us in 2003). The optical monitoring system measures two of the most important parameters of the photovoltaic thin films during deposition on a moving solar panel - material bandgap and surface roughness. In this program each sensor array consists of two fiber optics sensors monitoring two independent areas of the panel under deposition. Based on the monitored parameters and their change in time and from position to position on the panel, the system is able to provide to the equipment operator immediate information about the thin films as they are deposited. This DoE Supply Chain program is considered the first step towards the development of intelligent optical control system capable of dynamically adjusting the manufacturing process “on-the-fly” in order to achieve better performance. The proposed system will improve the thin film solar cell manufacturing by improving the quality of the individual solar cells and will allow for the manufacturing of more consistent and uniform products resulting in higher solar conversion efficiency and manufacturing yield. It will have a significant impact on the multibillion-dollar thin film solar market. We estimate that the financial impact of these improvements if adopted by only 10% of the industry ($7.7 Billion) would result in about $1.5 Billion in savings by 2015 (at the assumed 20% improvement). This can be achieved by optimizing the manufactured product and process in real time without changing the manufacturing technology.

14 SOLAR ENERGY↗

Performance of a high-sensitivity dedicated cardiac SPECT scanner for striatal uptake quantification in the brain based on analysis of projection data

Purpose: The authors have previously reported the advantages of high-sensitivity single-photon emission computed tomography (SPECT) systems for imaging structures located deep inside the brain. DaTscan (Isoflupane I-123) is a dopamine transporter (DaT) imaging agent that has shown potential for early detection of Parkinson disease (PD), as well as for monitoring progression of the disease. Realizing the full potential of DaTscan requires efficient estimation of striatal uptake from SPECT images. They have evaluated two SPECT systems, a conventional dual-head gamma camera with low-energy high-resolution collimators (conventional) and a dedicated high-sensitivity multidetector cardiac imaging system (dedicated) for imaging tasks related to PD. Methods: Cramer-Rao bounds (CRB) on precision of estimates of striatal and background activity concentrations were calculated from high-count, separate acquisitions of the compartments (right striata, left striata, background) of a striatal phantom. CRB on striatal and background activity concentration were calculated from essentially noise-free projection datasets, synthesized by scaling and summing the compartment projection datasets, for a range of total detected counts. They also calculated variances of estimates of specific-to-nonspecific binding ratios (BR) and asymmetry indices from these values using propagation of error analysis, as well as the precision of measuring changes in BR on the order of the average annual decline in early PD. Results: Under typical clinical conditions, the conventional camera detected 2 M counts while the dedicated camera detected 12 M counts. Assuming a normal BR of 5, the standard deviation of BR estimates was 0.042 and 0.021 for the conventional and dedicated system, respectively. For an 8% decrease to BR = 4.6, the signal-to-noise ratio were 6.8 (conventional) and 13.3 (dedicated); for a 5% decrease, they were 4.2 (conventional) and 8.3 (dedicated). Conclusions: This implies that PD can be detected earlier with the dedicated system than with the conventional system; therefore, earlier identification of PD progression should be possible with the high-sensitivity dedicated SPECT camera.

60 APPLIED LIFE SCIENCES↗

Emplacement Room Mock-up Structure for Testing the Placement of Nuclear Waste Within a Deep Geologic Repository - 19271

The Nuclear Waste Management Organization (NWMO) has conceptualized a unique method of long-term storage for spent nuclear waste. The concept encompasses all aspects of the end-of-life process from the point the spent fuel is no longer in-service; including handling, shipping, containing, storing, monitoring, and finally decommissioning. The equipment developed for each process is unique and designed specifically for each operation. Since these methods have not been implemented before, it is required to prove each process and the related equipment through simulations and eventually practical tests to evaluate performance and to confirm effective and safe operation. The spent fuel will be stored in an underground repository several hundred meters below the surface using autonomous machinery. Considering the significant investment and labour involved in creating full-scale tests underground, it would be impractical at this project stage to attempt tests of the newly developed machinery and methods in other than a surface setting. Therefore, our scope was to provide a customizable mock-up structure to simulate the conditions and constraints an underground repository would present. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The 'Room within a Room' Concept for Monitored Warhead Dismantlement

Over the past 10 years, US and UK experts have engaged in a technical collaboration with the aim of improving scientific and technological abilities in support of potential future nuclear arms control and non-proliferation agreements. In 2011 a monitored dismantlement exercise provided an opportunity to develop and test potential monitoring technologies and approaches. The exercise followed a simulated nuclear object through a dismantlement process and looked to explore, with a level of realism, issues surrounding device and material monitoring, chain of custody, authentication and certification of equipment, data management and managed access. This paper focuses on the development and deployment of the ‘room-within-a-room’ system, which was designed to maintain chain of custody during disassembly operations. A key challenge for any verification regime operating within a nuclear weapon complex is to provide the monitoring party with the opportunity to gather sufficient evidence, whilst protecting sensitive or proliferative information held by the host. The requirement to address both monitoring and host party concerns led to a dual function design which: • Created a controlled boundary around the disassembly process area which could provide evidence of unauthorised diversion activities. • Shielded sensitive disassembly operations from monitoring party observation. The deployed room-within-a-room was an integrated system which combined a number of chain of custody technologies (i.e. cameras, tamper indicating panels and enclosures, seals, unique identifiers and radiation portals) and supporting deployment procedures. This paper discusses the bounding aims and constraints identified by the monitoring and host parties with respect to the disassembly phase, the design of the room-within-a-room system, lessons learned during deployment, conclusions and potential areas of future work. Overall it was agreed that the room-within-a-room approach was effective but the individual technologies used to create the system deployed during this exercise required further development.

Nuclear Weapon, Dismantlement, Chain of Custody, C↗

Predicting Deposition Rate and Closing the Loop on Aerosol Jet Printing with In‐Line Light Scattering Measurements

Aerosol jet printing is a compelling noncontact, digital manufacturing technology for flexible, hybrid, and conformal electronics, but batch‐to‐batch variability and process drift inhibit systematic study and translation to production environments. Emerging measurement techniques for the aerosol volume fraction, a key parameter governing deposition rate, have shown promise for real‐time response, including a recent demonstration of human‐in‐the‐loop control. By integrating improved light scattering measurements with custom software, a robust environment for real‐time monitoring is established and fully automated closed‐loop control over the deposition rate during printing is enabled. The physical basis for scattering measurements as a feedback source is examined and the quantitative insight this provides for ink development and fundamental process studies is highlighted. Three candidate process variables for closed‐loop control, namely the atomizer voltage, carrier gas flow rate, and print speed, are then evaluated. The atomizer voltage demonstrates the best extended duration validity because it addresses atomization variability directly, but carrier gas flow rate and print speed provide faster and more deterministic responses. This methodology is then demonstrated for electrical properties using a silver nanoparticle ink, maintaining 98% of printed patterns within 10% of the mean resistance value over 3 h of printing.

36 MATERIALS SCIENCE↗

Towards real time diagnostics of Hybrid Welding Laser/GMAW

Methods are currently being developed towards a more robust system real time feedback in the high throughput process combining laser welding with gas metal arc welding. A combination of ultrasonic, eddy current, electronic monitoring, and visual techniques are being applied to the welding process. Initial simulation and bench top evaluation of proposed real time techniques on weld samples are presented along with the concepts to apply the techniques concurrently to the weld process. Consideration for the eventual code acceptance of the methods and system are also being researched as a component of this project. The goal is to detect defects or precursors to defects and correct when possible during the weld process.

42 ENGINEERING↗

An overview of the Department of Energy's CarbonSAFE Initiative: Moving CCUS toward commercialization

The U.S. Department of Energy (DOE) Office of Fossil Energy (FE) National Energy Technology Laboratory (NETL) Carbon Storage Program helps develop technologies that safely and permanently store carbon dioxide (CO 2 ) without adversely impacting natural resources or hindering economic growth. Since 1997, the program has significantly advanced carbon capture, utilization, and storage (CCUS) science and technology, with more than 10.5 million metric tons (MMT) of CO 2 safely stored. However, key gaps in experience and knowledge remain (e.g., the technology, expertise, and processes needed to safely characterize and monitor 50+ MMT-scale geologic CO 2 storage sites). DOE's Carbon Storage Assurance Facility Enterprise (CarbonSAFE) Initiative (launched in FY16) is beginning to address this gap. The CarbonSAFE Initiative currently consists of 13 projects in Phase I: Integrated Carbon Capture and Storage (CCS) Pre-Feasibility and six projects in Phase II: Storage Complex Feasibility. Here this article includes the latest updates from the CarbonSAFE Initiative.

01 COAL, LIGNITE, AND PEAT↗