Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiator Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Optical diagnostic design for measuring the radiation front with a mid-leg pumped divertor on DIII-D

The design of an optical diagnostic system to localize the radiation front in a mid-leg pumped divertor configuration on DIII-D is presented. Divertor detachment is a key mechanism for handling power exhaust in tokamaks, and mid-leg pumping offers a promising approach to radiatively dissipate power while maintaining acceptable core performance. To predict the location of the radiation front and design a spectroscopic diagnostic to measure its position, a database of SOLPS-ITER simulations across a range of input powers and gas puffing rates representative of DIII-D operation was employed. These simulations provide self-consistent plasma backgrounds for a Cherab-Raysect synthetic diagnostic framework, which incorporates detailed tokamak geometry and physically accurate ray-tracing. Synthetic simulations of optical sightlines and viewing cone geometry were used to calculate line-integrated emission from the plasma, particularly of the C III 465 nm line, to serve as a proxy for the T e ≈ 7 − 10 eV temperature region associated with the onset and evolution of divertor detachment. Neutral deuterium emission is also evaluated for comparison. The synthetic diagnostic is used to assess the performance of existing DIII-D optical systems, including filterscopes and the Multichord Divertor Spectrometer, and to optimize line-of-sight placement within mechanical and installation constraints. The results provide quantitative guidance for diagnostic implementation on DIII-D and demonstrate the advantage of integrated synthetic diagnostics for divertor design studies and future advanced divertor concepts.

Cherab↗

Radiation damage in lithium-counterdoped n/p silicon solar cells

Lithium counterdoped n+/p silicon solar cells were irradiated with 1 MV electrons and their post irradiation performance and low temperature annealing properties were compared to that of the 0.35 ohm cm control cells. Cells fabricated from float zone and Czochralski grown silicon were investigated. It was found that the float zone cells exhibited superior radiation resistance compared to the control cells, while no improvement was noted for the Czochralski grown cells. Room temperature and 60 C annealing studies were conducted. The annealing was found to be a combination of first and second order kinetics for short times. It was suggested that the principal annealing mechanism was migration of lithium to a radiation induced defect with subsequent neutralization of the defect by combination with lithium. The effects of base lithium gradient were investigated. It was found that cells with negative base lithium gradients exhibited poor radiation resistance and performance compared to those with positive or no lithium gradients; the latter being preferred for overall performance and radiation resistance.

Hermann, A. M.↗

TU-H-BRA-06: Characterization of a Linear Accelerator Operating in a Compact MRIGuided Radiation Therapy System

Purpose: To describe the performance of a linear accelerator operating in a compact MRI-guided radiation therapy system. Methods: A commercial linear accelerator was placed in an MRI unit that is employed in a commercial MR-based image guided radiation therapy (IGRT) system. The linear accelerator components were placed within magnetic field-reducing hardware that provided magnetic fields of less than 40 G for the magnetron, gun driver, and port circulator, with 1 G for the linear accelerator. The system did not employ a flattening filter. The test linear accelerator was an industrial 4 MV model that was employed to test the ability to run an accelerator in the MR environment. An MR-compatible diode detector array was used to measure the beam profiles with the accelerator outside and inside the MR field and with the gradient coils on and off to examine if there was any effect on the delivered dose distribution. The beam profiles and time characteristics of the beam were measured. Results: The beam profiles exhibited characteristic unflattened Bremsstrahlung features with less than ±1.5% differences in the profile magnitude when the system was outside and inside the magnet and less than 1% differences with the gradient coils on and off. The central axis dose rate fluctuated by less than 1% over a 30 second period when outside and inside the MRI. Conclusion: A linaccompatible MR design has been shown to be effective in not perturbing the operation of a commercial linear accelerator. While the accelerator used in the tests was 4MV, there is nothing fundamentally different with the operation of a 6MV unit, implying that the design will enable operation of the proposed clinical unit. Research funding provided by ViewRay, Inc.

60 APPLIED LIFE SCIENCES↗

Zero-dimensional Cs 4 EuX 6 (X = Br, I) all-inorganic perovskite single crystals for gamma-ray spectroscopy

Organic–inorganic and all-inorganic halide perovskites have become leading candidates toward high-performance optoelectronic devices and radiation detectors. In this work, we report novel zero-dimensional Cs 4 EuX 6 (X = Br, I) perovskite single crystals as self-activated scintillators with superior performance for gamma-ray spectroscopy. Both Cs 4 EuBr 6 and Cs 4 EuI 6 single crystals grown by the Bridgman method were determined to have the trigonal crystal structure with the R$\bar{3}$c space group, and have a melting point of approximately 540°C. Cs 4 EuBr 6 and Cs4EuI 6 exhibit blue emission under UV excitation and high light yields of 78,000 ± 4000 photons/MeV and 53,000 ± 3000 photons/MeV under 137 Cs gamma-ray irradiation, respectively. In particular, the former represents the best result achieved for self-activated scintillators thus far. Thermally stimulated luminescence studies and density functional theory calculations elucidate the correlation between halogen vacancies and long-lived emission (afterglow) at room temperature in Cs4EuX 6 (X=Br, I) single crystals. In conclusion, our findings not only demonstrate the high gamma-ray detection efficiency in Cs 4 EuX 6 (X=Br, I), but will further promote the development of 0D metal halide-based novel luminescent and radiation detection materials.

36 MATERIALS SCIENCE↗

Short-term solar radiation forecast using total sky imager via transfer learning

Ground-based sky cameras, which capture hemispherical images, have been extensively used for localized monitoring of clouds. This paper proposes a short-term forecasting approach based on transfer learning using Total Sky-Imager (TSI) images of the Southern Great Plains (SGP) site obtained from the Atmospheric Radiation Measurement (ARM) dataset. An accurate estimation of solar irradiance using TSI is key for short-term solar energy generation forecasting and optimal energy consumption planning. We make use of deep neural network architectures such as AlexNet and ResNet-101 to extract the underlying deep convolution features from TSI images and then train using an ensemble learning approach to model and forecast solar radiation. We demonstrate the performance of the proposed approach by showcasing the best and worst cases. Thus, the transfer learning approach significantly reduces the time and resources required for modeling solar radiation. We outperform with reference to another state-of-art technique for solar modeling using TSI images at different forecast lead times.

54 ENVIRONMENTAL SCIENCES↗

Telescope performance and image simulations of the balloon-borne coded-mask protoMIRAX experiment

In this work we present the results of imaging simulations performed with the help of the GEANT4 package for the protoMIRAX hard X-ray balloon experiment. The instrumental background was simulated taking into account the various radiation components and their angular dependence, as well as a detailed mass model of the experiment. We modelled the meridian transits of the Crab Nebula and the Galactic Centre (CG) region during balloon flights in Brazil (∼ −23° of latitude and an altitude of ∼40 km) and introduced the correspondent spectra as inputs to the imaging simulations. We present images of the Crab and of three sources in the GC: 1E 1740.7-2942, GRS 1758-258 and GX 1+4. The results show that the protoMIRAX experiment is capable of making spectral and timing observations of bright hard X-ray sources as well as important imaging demonstrations that will contribute to the design of the MIRAX satellite mission.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An Experimental Facility Concept Revolutionizing Materials in Extremes

The planned Matter-Radiation Interactions in Extremes (MaRIE) facility at Los Alamos National Lab (LANL) is designed to fill a void in the materials research community. This void is the ability to study materials under extreme conditions (such as in high radiation environments). Ultimately, we want to be able to predict and control materials under extreme conditions. An example of where this capability is needed is in the performance of materials in advanced energy systems. The understanding of materials needs to move from the nano scale all the way to bulk systems. This talk discusses present capabilities for understanding materials at the Los Alamos Neutron Science Center (LANSCE) at LANL and the future capabilities MaRIE brings, including from the Multi-Probe Diagnostic Hall, the Fission, Fusion Materials Facility, and the Making, Measuring, Modeling and Materials Facility.

36 MATERIALS SCIENCE↗

A numerical study of the spectral radiative properties of packed bed with mixed bauxite and silica spheres

Bauxite and silica particles have gained increasing attention for applications in the field of concentrated solar power. In this work, a Monte Carlo ray-tracing simulation is performed to predict the radiative properties (absorptance, reflectance, and transmittance) of packed beds with mixed bauxite and silica spherical particles at wavelengths of 0.5, 2.6, 9.0, and 9.35 µm. These wavelengths are representative for the visible, near-infrared, and the mid-infrared regions that are important for solar and thermal radiation, respectively. A repeating unit-column approach is used to mathematically represent the particle bed. The effects of particle mixing ratio, volume fraction, and wavelength on the predicted radiative properties are examined. The obtained radiative properties are inputted to an inverse method to retrieve the effective absorption and scattering coefficients as well as the scattering albedo, which may be later used in a continuous-scale radiative heat transfer analysis. Furthermore, the independent scattering model is used to obtain the absorption coefficient and scattering albedo based on the absorption and scattering cross sections predicted by a Monte Carlo algorithm for a single particle. It is shown that the independent scattering model underpredicts the scattering coefficient for opaque particles but overpredicts the scattering coefficient for semitransparent particles for sufficiently high particle volume fractions. Here, the radiative properties calculated from the independent scattering model are compared to the full Monte Carlo simulation of the particle bed to examine the influence of particle mixing on dependent scattering.

42 ENGINEERING↗

Clinical implementation of radiosurgery using the Helical TomoTherapy unit

The American Society of Radiation Oncology has recently recommended the use of radiosurgery to manage brain metastases. For such a recommendation to be implemented in a widespread manner, radiosurgery must be accessible at community radiation therapy facilities. The work presented here describes our clinical experience in the implementation of radiosurgery using a Helical TomoTherapy unit. Helical TomoTherapy is a unique dose-delivery system designed to perform intensity-modulated radiation therapy (IMRT). The system built on the ring-based gantry has the tight machine tolerances required for radiosurgery. A frameless system consisting of a thermoplastic mask and a noninvasive ''stereotactic radiosurgery (SRS)-stereotactic radiotherapy (SRT)'' fixation device is used for patient immobilization. Treatment planning is performed using the TomoHD treatment planning system designed for IMRT. The image-guidance system on the Helical TomoTherapy is used for patient localization. Our clinical experience demonstrated that the radiosurgery procedure can be streamlined as we do for IMRT patients. The treatment time of about 10 minutes is comparable with that for IMRT patients. The same patient-specific quality assurance for IMRT is used for radiosurgery. As demonstrated, SRS using Helical TomoTherapy is not a whole-day event, unlike SRS using other dose-delivery systems or SRS performed in the past.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Two-tiered design analysis of a radiator for a solar dynamic powered Stirling engine

Two separate design approaches for a pumped loop radiator used to transfer heat from the cold end of a solar dynamic powered Stirling engine are described. The first approach uses a standard method to determine radiator requirements to meet specified end of mission conditions. Trade-off studies conducted for the analysis are included. Justification of this concept within the specified parameters of the analysis is provided. The second design approach determines the life performance of the radiator/Stirling system. In this approach, the system performance was altered by reducing the radiator heat transfer area. Performance effects and equilibrium points were determined as radiator segments were removed. This simulates the effect of loss of radiator sections due to micro-meteoroid and space debris penetration. The two designs were compared on the basis of overall system requirements and goals.

Hainley, Donald C.↗

Two-tiered design analysis of a radiator for a solar dynamic powered Stirling engine

Two separate design approaches for a pumped loop radiator used to transfer heat from the cold end of a solar dynamic powered Stirling engine are described. The first approach uses a standard method to determine radiator requirements to meet specified end of mission conditions. Trade-off studies conducted for the analysis are included. Justification of this concept within the specified parameters of the analysis is provided. The second design approach determines the life performance of the radiator/Stirling system. In this approach, the system performance was altered by reducing the radiator heat transfer area. Performance effects and equilibrium points were determined as radiator segments were removed. This simulates the effect of loss of radiator sections due to micro-meteoroid and space debris penetration. The two designs are compared on the basis of overall system requirements and goals.

Hainley, Donald C.↗

Simulation of picosecond pulse propagation in fibre-based radiation shaping units

We have performed a numerical simulation of picosecond pulse propagation in a combined stretcher consisting of a segment of a telecommunication fibre and diffraction holographic gratings. The process of supercontinuum generation in a nonlinear photonic-crystal fibre pumped by picosecond pulses is simulated by solving numerically the generalised nonlinear Schrödinger equation; spectral and temporal pulse parameters are determined. Experimental data are in good agreement with simulation results. The obtained results are used to design a high-power femtosecond laser system with a pulse repetition rate of 1 kHz.

42 ENGINEERING↗

Radiation Effects on Flow Characteristics in Combustion Chambers

A JANNAF sponsored workshop was held to discuss the importance and role of radiative heat transfer in rocket combustion chambers. The potential impact of radiative transfer on hardware design, reliability, and performance was discussed. The current state of radiative transfer prediction capability in CFD modeling was reviewed and concluded to be substantially lacking in both the physical models used and the radiative property data available. There is a clear need to begin to establish a data base for making radiation calculations in rocket combustion chambers. A natural starting point for this effort would be the NASA thermochemical equilibrium code (CEC).

Brewster, M. Q.↗

LDEF Satellite Radiation Analyses

This report covers work performed by Science Applications International Corporation (SAIC) under contract NAS8-39386 from the NASA Marshall Space Flight Center entitled LDEF Satellite Radiation Analyses. The basic objective of the study was to evaluate the accuracy of present models and computational methods for defining the ionizing radiation environment for spacecraft in Low Earth Orbit (LEO) by making comparisons with radiation measurements made on the Long Duration Exposure Facility (LDEF) satellite, which was recovered after almost six years in space. The emphasis of the work here is on predictions and comparisons with LDEF measurements of induced radioactivity and Linear Energy Transfer (LET) measurements. These model/data comparisons have been used to evaluate the accuracy of current models for predicting the flux and directionality of trapped protons for LEO missions.

Armstrong, T. W.↗

Recent Advances in Binary Black Hole Merger Simulations

Recent advances in numerical simulation techniques have lead to dramatic progress in understanding binary black hole merger radiation. I present recent results from simulations performed at Goddard, focusing on the gravitational radiation waveforms, and the application of these results to gravitational wave observations.

Barker, John↗

Modeling Space Radiation Induced Bone Changes in Rat Femurs through Finite Element Analysis

As the duration of manned missions outside of the Earth’s protective shielding increase, astronauts are at risk for exposure to space radiation. Various organ systems may be damaged due to exposure. This study investigates the bonestrength changes using finite element modeling of Long Evans rats (n=85) subjected to graded, head-only proton (0, 10, 25, and 100 cGy, 150 MeV/n) and 28silicon (0, 10, 25, and 50 cGy, 300 MeV/n) radiation. The strength of the femoral neck will be examined due its clinical relevance to hip fractures. It has been shown in previous studies that bone mineral density was not reduced at the site of fracture. These findings question whether measurements of bone mineral density may be used to assess risk of hip fracture. The mechanisms leading to the irregular relationship between bone density and strength are still uncertain within literature and investigated to greater extent in clinical applications. Finite element analysis within this study simulated physiological loading of the femoral neck. No significant changes in femoral neck strength were found across doses of proton or 28silicon head-only radiation. Future work includes performing mechanical testing of the bone samples. Moving from mouse to larger animal models may also provide the increased lifespan for assessing the long-term outcomes of radiation exposure.

Dale Johnson↗

Micron-focused ion beamlets

A multiple beam electrode system (MBES) is used to provide focused ion beamlets of elements from a compact microwave plasma. In this study, a honeycomb patterned plasma electrode with micron size apertures for extracting ion beamlets is investigated. The performance of the MBES is evaluated with the help of two widely adopted and commercially available beam simulation tools, AXCEL-INP and SIMION, where the input parameters are obtained from our experiments. A simple theoretical model based upon electrostatic ray optics is employed to compare the results of the simulations. It is found that the results for the beam focal length agree reasonably well. Different geometries are used to optimize the beam spot size and a beam spot {approx}5-10 {mu}m is obtained. The multiple ion beamlets will be used to produce microfunctional surfaces on soft matter like polymers. Additionally, the experimental set-up and plans are presented in the light of above applications.

43 PARTICLE ACCELERATORS↗