Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reference Model 3”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Design and Optimization of Structured Multi-Functional Trapping Catalysts for Conversion of Hydrocarbons and NOx from Diesel and Advanced Combustion Engines

Oxides of nitrogen in the form of nitric oxide (NO) and nitrogen dioxide (NO 2 ) commonly referred to as NOx, is one of the two chemical precursors that lead to ground-level ozone, a ubiquitous air pollutant in urban areas. A major source of NOx is generated by equipment and vehicles powered by diesel engines, which have a combustion exhaust that contains NOx in the presence of excess O 2 . Vehicular emission control catalysts are ineffective in eliminating CO, hydrocarbons, and NO x during engine cold-start when exhaust temperatures are below 200°C. The objective of the project was to develop and demonstrate a multi-functional, catalyzed trap that enables vehicles with advanced combustion strategies to meet Tier 3 emissions standards while achieving the 150 °C challenge for sustained co-oxidation of HCs and CO and ≥90% NO trapping and release during warmup. Specifically, the multi-functional Lean HC+NOx (LHCNT) was developed for application in the exhaust aftertreatment of conventional diesel engines and engines having low temperature combustion (LTC) regimes. Activities included the design and synthesis of adsorbents and catalysts, screening and evaluation. Passive NOx absorbers (PNA), hydrocarbon (HC) traps, and oxidation catalysts (OC) were evaluated for use in series or as integrated devices. Predictive tools were developed utilizing the characterization and analysis of these materials, and an emission system was designed and optimized utilizing the catalyst systems. Microkinetic models were developed for the PNA for the simple NO-only feed and complex feed containing CO, H 2 , and model hydrocarbons (ethylene and dodecane). A first-principles, mechanistic-based model of the PNA was developed which utilized molecular-scale estimates (density functional theory) of energy barriers, mechanistic-based kinetics and realistic treatments of the flow and transport processes. Two new oxidation catalysts were developed (PdCu alloy, mixed copper-ceria-cobalt oxide), both of which significantly lessened the detrimental inhibition by CO on hydrocarbon and NO oxidation. A method for lessening the detrimental impact of CO on PNA activity was developed that involves use of an oxidation catalyst upstream of the PNA. The SwRI Ectolab TM burner system was applied to evaluate the baseline PNA material and confirmed performance comparable to the benchflow PNA studies using simulated exhaust. Spatially-resolved mass spectrometry (SpaciMS) was used to measure the transient spatial profiles of reacting species spanning the length of a three-function LHCNT containing PNA, HCT, and OC. The findings from this study provide diesel vehicle and catalyst companies valuable information to develop more cost effective emission control catalysts which helps to expand the use of more fuel efficient diesel power. The fundamental modeling and experimental tools and findings from this project can be applied to catalyst technologies used in the energy and chemical industries. The project led to 14 publications in the peer-reviewed literature with 2 additional currently under review. Finally, the project also led to training of several doctoral students who were placed in research jobs in industry and academia. Specifically, Mugdha Ambast (UH) has joined Cummins, Kevin Gu (UVa) has joined GM, and Abhay Gupta (UH) is to join Caterpillar.

42 ENGINEERING↗

Test and Analysis of the 8-foot Diameter Cylindrical Sandwich Composite Test Article CTA8.2B: As part of the NASA Engineering and Safety Center Shell Buckling Knockdown Factor Project

The buckling response of thin-walled cylindrical structures have long been shown to be sensitive to various imperfections. That is, imperfections related to load introduction, boundary conditions, material property variation, and geometric deviations can all contribute to experimentally obtained buckling loads being lower than the buckling loads predicted for perfect representations of the same thin-walled cylindrical structure. To account for the influence of geometry-based imperfections of a thin-walled cylindrical structure on buckling response, a design factor (also known as a buckling knockdown factor) is used during the design phase. Guidelines for buckling knockdown factors are readily available in NASA SP-8007, Buckling of Thin Walled Circular Cylinders, which was updated in 2020. Prior to this recent update, NASA SP-8007 had not been updated since 1969, and since that time, computational analysis, experimental testing, and manufacturing methods have significantly improved. The NASA Engineering and Safety Center (NESC) Shell Buckling Knockdown Factor Project (SBKF, NESC Assessment 07-010-E) had the goal of developing buckling design recommendations for select classes of metallic and composite launch-vehicle structures [3]. Specifically, the test and analysis results from the fourth SBKF composite test article SBKF-P3-CYL-CTA8.2B, which is referred to as CTA8.2B, are described in this paper. This test was the fourth in a series of four tests on sandwich composite cylinders that will be used to experimentally validate analysis methods, which in turn can be used to develop new analysis-based shell buckling design guidelines for typical sandwich composite launch vehicle cylindrical structures. Publications describing previous test validation with analysis are available in Refs. CTA8.2B was designed to occupy one corner of the design space with approximately equal bending stiffnesses in the axial and transverse directions and have a larger ratio of radius to effective shell thickness. Each test article had a unique design and was designed to occupy a specific region of the design space. CTA8.2B was an 8-foot diameter honeycomb-core sandwich cylinder that was fabricated and tested at the NASA Marshall Space Flight Center (MSFC). The primary objectives of this test were to interrogate the structural capability of a composite test article, and to verify the test article design and analysis approach for cylinders subjected to axial compression and combined axial and bending loads. First, descriptions of the test article design and test are given in Section 2.0, and modeling and analysis methods used in support of the test article design and testing activities are described briefly in Section 3.0. Then, select test results are presented and compared to predicted results in Section 4.0, and concluding remarks are presented in Section 5.0. Finally, drawings of CTA8.2B and references used to support the test and analysis are provided in the Appendix.

Nonlinear analysis↗

Development and Testing of Pulse Guns for Combustion Instability Testing

To test liquid rocket engines (LREs) for combustion instabilities, devices such as bombs are often used to create pressure wave disturbances. Bombs, while effective, are inherently dangerous, expensive, and difficult to procure. Over the years, pulse guns have been used as a safer and more cost-effective way to generate controlled pressure disturbances in engine chambers. In anticipation of the need for stability testing of prototype LREs at NASA Marshall Space Flight Center (MSFC), a set of pulse guns have been designed, fabricated, tested, and characterized. The pulse gun program is funded by the RS-25 Engine Program managed out of MSFC and funded by NASA’s Space Launch System (SLS) through the MSFC Liquid Engines Office (LEO). A pulse gun is a simple device – like a traditional gun, it has a breech and barrel section. However, unlike a traditional gun, there is no bullet, as the purpose of the pulse gun is strictly to fire a high pressure pulse. Instead of a firing pin and primer that would normally be used in a traditional gun, an initiator is used to activate the gun powder. The initiator is a highly reliable pyrotechnic initiator. For this study, clone versions of the NASA Standard Initiator (NSI) were used. The initiator is used to ignite a pre-measured amount of gun powder loaded into the breech. When the pressure of the burnt gun powder exceeds the set point of a downstream burst disk, the disk ruptures, allowing the high pressure pulse to travel downstream through the barrel section. A ballistic pressure transducer located in the breech section is used to measure the short duration, high pressure pulse. Some configurations of the pulse gun have barrel sections that include one or more additional ballistic pressure transducers. These additional pressure measurements help track the degradation and damping of the pulse as it travels out of the barrel section. The measurements may also be used to determine the velocity of pulse. The objective of this paper is to present the different variants of this newly-developed pulse gun and characterize performance over a range of parameters. The parameters include breech diameter, barrel length, amount of gun powder used, the way the gun powder is packed, and the pressure setting of the burst disk. There are a total of six pulse guns: three with the 0.25 inch breech and three different length barrels, and three with the 0.40 inch breech and three different length barrels. For both breech sizes, the associated barrels are referred to as standard, one-port, and two-port barrels. The standard barrel has no instrumentation and is likely the barrel that will be used for engine stability testing. The one- and two-port barrels were designed specifically for pulse gun component testing to allow measurements of the magnitude and timing of the high pressure pulse as it makes its way through the pulse gun. The burst disks tested were commercially-available burst disks designed to rupture at 8,000, 16,000, and 24,000 psid. Testing was accomplished by firing the pulse gun into a test chamber pressurized with nitrogen at about 2300 psig. A total of four Model 113B23 High frequency ICP® pressure sensors (10k psi) were mounted in the test chamber, in the same plane as the pulse gun. Two of the sensors had “trimmed” adapters, and two did not. Given the symmetrical configuration of the sensors within the test chamber, different amplitudes of pressure measurements are attributed to the use of trimmed versus untrimmed adapters. The untrimmed adapters, with their narrower passages, tended to amplify the pressure amplitudes by as much as 50%. In total, 41 pulse gun tests have been conducted.Data are still being analyzed, but some trends are apparent. For example, measurements taken within the pulse gun are shown in Figures 3 and 4 for Hot-fires (HFs) # 11 and 39, respectively. Both tests were identical in that the 0.40 inch ID breech, two-port barrel, 8,000 psid burst disk, and same amount of gunpowder (6.639 grains for HF# 11, and 6.576 grains for HF# 39) were used, and the back pressure in the nitrogen test chamber was ~2300 psig. Despite keeping all these variables constant, the results from these two tests look quite different. For both tests, the first pressure peak shown in the P2111 trace within the breech is the firing of the initiator. The second peak and any subsequent peaks are from the combustion of the gunpowder. It should be noted that because the sensors are dynamic, the ~2300 psig baseline static pressure is not shown in the figures. For HF# 11, the burst disk clearly ruptured in a little over 0.1 ms from the time the initiator was fired. This is evident from the abrupt rise in pressure for P2112 followed by another abrupt rise in pressure for P2113. The sensors track the movement of the high pressure pulse through the pulse gun. For HF# 39, however, there was nearly 1 ms delay between the initiator firing and the burst disk rupturing. The only difference between these two tests was the way in which the gunpowder was packed within the breech. For HF# 11, the gunpowder was poured directly into the breech, atop the initiator, and held in place with a vegetable fiber wad appropriately sized for the barrel diameter. Once in place, the wad firmly held the gunpowder in place. For HF# 39, the gunpowder was rolled within cigarette paper with the ends of the paper twisted. The rolled gunpowder was gently pushed down into the breech, toward the initiator, and no wad was used. This method of loading the gunpowder consistently produced longer delays in the rupture of the burst disk, presumably because there was a steady, fuller burning of the gunpowder. The burst disk was rated for 8,000 psid, which means that the burst disk should not have opened until the pressure in the breech reached ~10,300 since there was ~2300 psig back pressure in the test chamber. In the case of HF# 11, the breech pressure only reached roughly 4200 psi before there was leakage either through or past the burst disk, but for HF#39, the breech pressure reached 10,600 psi prior to the burst disk opening. The temperature of the burst disk is certainly a factor in determining when the burst disk will rupture. A sharp rise in the burst disk temperature could weaken it and cause it to stray from the designed set point burst pressure. The burst disks are manufactured of Inconel to try to reduce their sensitivity to temperature, but how the burst disks perform above 900°F is not documented. All burst disks were engineered and tested by the manufacturer for ambient temperature conditions. One theory for why rolling the gunpowder in cigarette paper may produce better results is related to a more controlled temperature environment. The cigarette paper may act as a sheath that protects the burst disk from excessive temperatures during the rapid buildup of pressure in the breech. The ultimate benefit of not breeching the burst disk prematurely is shown in Figures 5 and 6, which graphs the resultant pressure pulse produced in the test chamber. For HF #11, the peak pressure on the P2123 trimmed adapter is about 270 psi, while for HF# 39 it is 343 psi, which is about 1.27 times greater in magnitude. In either case, the pressure pulse is ~20 μs in width once it reaches the test chamber. Another pressure rise about 100 μs later can be seen on the sensors located across from the pulse gun port, P2124 and P2121. These pressures are lower due to attenuation of the pressure wave as it moves across the test chamber. After the wave encounters the wall, it reflects back and forth within the chamber until it completely dissipates.

Pulse Gun↗

Comment on "Observation of Large and All-Season Ozone Losses Over the Tropics" [AIP Advances 12, 075066 (2022)]

As discussed above, and supported by extensive literature, there is no robust, credible observational evidence for substantial ozone depletion (i.e., an “ozone hole”) in the tropics. It is well known that climatological total ozone in the tropics is much lower than that in the mid-latitudes (e.g., Sahai et al., 2000; Weber et al., 2022). Satellite and ozonesonde measurements indicate a 3%–5% per decade decline of tropical lower stratosphere ozone prior to 2000, far smaller than that reported by L2022. The stronger decline reported by L2022 is caused by inappropriate use of the gap-filled version of the TOST ozone dataset, which is based on sparse tropical ozone sondes before the 1990s. This misuse of data (TOST and total column ozone) shows the importance of collaboratively engaging with groups who obtain the measurements and create climatological datasets before performing such analyses. Furthermore, the study by L2022 has multiple flaws in its discussion of atmospheric chemistry and dynamics, particularly in the proposed, and previously refuted (see Sec. III A), cosmicray- driven electron induced (CRE) mechanism. Evidence for the occurrence of tropical stratospheric clouds, as needed for the tropical CRE mechanism, is lacking, nor do CFC-12 observations show signatures of depletion in the tropical lower stratosphere, which could be associated with dissociative electron attachment-induced loss of CFC-12 on particulate matter (i.e., the CRE mechanism). Finally, it is worth reiterating that the CRE mechanism is also not responsible for polar LS ozone depletion. Polar ozone loss can be well explained by the gas phase and heterogeneous chemistry, based on extensive observations and modeling studies documented in many thousands of scientific papers on the topic [e.g., see WMO (2018) and references therein], which is not acknowledged by L2022. L2022’s research paper is a severely flawed one. There is no tropical ozone hole, and the CRE mechanism does not explain observed changes in stratospheric ozone either in the polar regions or in the tropics.

Quality assurance↗

Technical aspects of real time positron emission tracking for gated radiotherapy

Purpose: Respiratory motion can lead to treatment errors in the delivery of radiotherapy treatments. Respiratory gating can assist in better conforming the beam delivery to the target volume. We present a study of the technical aspects of a real time positron emission tracking system for potential use in gated radiotherapy. Methods: The tracking system, called PeTrack, uses implanted positron emission markers and position sensitive gamma ray detectors to track breathing motion in real time. PeTrack uses an expectation–maximization algorithm to track the motion of fiducial markers. A normalized least mean squares adaptive filter predicts the location of the markers a short time ahead to account for system response latency. The precision and data collection efficiency of a prototype PeTrack system were measured under conditions simulating gated radiotherapy. The lung insert of a thorax phantom was translated in the inferior–superior direction with regular sinusoidal motion and simulated patient breathing motion (maximum amplitude of motion ±10 mm, period 4 s). The system tracked the motion of a {sup 22}Na fiducial marker (0.34 MBq) embedded in the lung insert every 0.2 s. The position of the was marker was predicted 0.2 s ahead. For sinusoidal motion, the equation used to model the motion was fitted to the data. The precision of the tracking was estimated as the standard deviation of the residuals. Software was also developed to communicate with a Linac and toggle beam delivery. In a separate experiment involving a Linac, 500 monitor units of radiation were delivered to the phantom with a 3 × 3 cm photon beam and with 6 and 10 MV accelerating potential. Radiochromic films were inserted in the phantom to measure spatial dose distribution. In this experiment, the period of motion was set to 60 s to account for beam turn-on latency. The beam was turned off when the marker moved outside of a 5-mm gating window. Results: The precision of the tracking in the IS direction was 0.53 mm for a sinusoidally moving target, with an average count rate ∼250 cps. The average prediction error was 1.1 ± 0.6 mm when the marker moved according to irregular patient breathing motion. Across all beam deliveries during the radiochromic film measurements, the average prediction error was 0.8 ± 0.5 mm. The maximum error was 2.5 mm and the 95th percentile error was 1.5 mm. Clear improvement of the dose distribution was observed between gated and nongated deliveries. The full-width at halfmaximum of the dose profiles of gated deliveries differed by 3 mm or less than the static reference dose distribution. Monitoring of the beam on/off times showed synchronization with the location of the marker within the latency of the system. Conclusions: PeTrack can track the motion of internal fiducial positron emission markers with submillimeter precision. The system can be used to gate the delivery of a Linac beam based on the position of a moving fiducial marker. This highlights the potential of the system for use in respiratory-gated radiotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

An Analysis of Neptune's Stratospheric Haze Using High-Phase-Angle Voyager Images

We have inverted high-phase-angle Voyager images of Neptune to determine the atmospheric extinction coefficient as a function of altitude and the scattering phase function at a reference altitude. Comparisons between theoretical model and observations help separate the contributions from molecular Rayleigh and aerosol scattering and help determine the variation of the aerosol size, concentration, and scattering properties with altitude. Further comparisons between models and data allow us to place constraints on the location and composition of the hazes, the concentration and downward flux of certain condensible hydrocarbon gases, the eddy diffusion coefficient in the lower stratosphere, and the thermal profile in parts of Neptune's stratosphere. We find that a distinct stratospheric haze layer exists near 12(sub -1, sup +1) mbar in Neptune's lower stratosphere, most probably due to condensed ethane. The derived stratospheric haze production rate of 1.0(sub -0.3, sup +0.2) x 10(exp -15) g cm(exp -2) sec(exp -1) is substantially lower than photochemical model predictions. Evidence for hazes at higher altitudes also exists. Unlike the situation on Uranus, large particles (0.08-0.11 microns) may be present at high altitudes on Neptune (e.g., near 0.5 mbar), well above the region in which we expect the major hydrocarbon species to condense. Near 28 mbar, the mean particle size is about 0.13(sub -0.02, sup +0.02) microns with a concentration of 5(sub -3, sup +3) particles cm(exp -3). The cumulative haze extinction optical depth above 15 mbar in the clear filter is approx. 3 x 10(exp -3), and much of this extinction is due to scattering rather than absorption; thus, if our limb-scan sites are typical, the hazes cannot account for the stratospheric temperature inversion on Neptune and may not contribute significantly to atmospheric heating. We compare the imaging results with the results from other observations, including those of the Voyager Photopolarimeter Subsystem, and discuss differences between Neptune and Uranus.

Moses, Julianne I.↗

Validation of Mars-GRAM and Planned New Features

For altitudes below 80 km, Mars Global Reference Atmospheric Model (Mars-GRAM 2001) is based on output climatology from NASA Ames Mars General Circulation Model (MGCM). At COSPAR 2002, results were presented of validation tests of Mars-GRAM versus data from Mars Global Surveyor Thermal Emission Spectrometer (TES) and Radio Science (RS) experiment. Further validation tests are presented comparing Mars- GRAM densities with those from the European Mars Climate Database (MCD), and comparing densities from both Mars-GRAM and MCD against TES observations. Throughout most of the height and latitude range of TES data (040 km and 70s to 70N), good agreement is found between atmospheric densities from Mars-GRAM and MCD. However, at the season and latitude zone for Mars Phoenix arrival and landing (Ls = 65 to 80 degrees and latitude 65 to 75N), Mars-GRAM densities are about 30 to 45 percent higher than MCD densities near 40 km altitude. Further evaluation is warranted concerning potential impact of these model differences on planning for Phoenix entry and descent. Three planned features for Mars-GRAM update are also discussed: (1) new MGCM and Thermospheric General Circulation Model data sets to be used as a revised basis for Mars-GRAM mean atmosphere, (2) a new feature to represent planetary-scale traveling waves for upper altitude density variations (such as found during Mars Odyssey aerobraking), and (3) a new model for effects of high resolution topographic slope on winds near the surface (0 to 4.5 km above MOLA topography level). Mars-GRAM slope winds will be computed from a diagnostic (algebraic) relationship based on Ye, Segal, and Pielke (1990). This approach differs from mesoscale models (such as MRAMS and Mars MM5), which use prognostic, full-physics solutions of the time- and space-dependent differential equations of motion. As such, slope winds in Mars-GRAM will be consistent with its "engineering-level" approach, and will be extremely fast and easy to evaluate, compared with mesoscale model solutions. Mars-GRAM slope winds are not being suggested as a replacement for sophisticated, full-physics Mars mesoscale models, but may have value, particularly for preliminary screening of large numbers of candidate landing sites for future Mars missions, such as Phoenix and Mars Science Laboratory. Test output is presented from Mars-GRAM slope winds in the area of Gusev Crater and Valles Marineris.

Justus, C. G.↗

Recommendations for Using Noise Monitors to Estimate Noise Exposure During X-59 Community Tests

A low fidelity simulation approach is used to explore how to place and use noise monitors during X-59 QueSST community tests, where people’s annoyance to the noise produced by the X-59 aircraft will be gathered. Several recommendations are provided including: 1) the desired number of sparsely spaced noise monitor sites within the survey area, 2) whether to group and average measurements across multiple noise monitors located at a site, 3) what spacing should be used if grouped noise monitors are used, 4) an approach to mitigate ambient noise contamination at the measurement sites, 5) a method to combine empirical and predicted dose estimates to provide a single dose estimate for respondents, and 6) assessing how changes in turbulence intensity and array configuration affect dose uncertainty. To make these recommendations, the error that is expected when fitting contrived, smoothly varying sonic boom “reference exposure surfaces” is studied when a spatially sparse and scattered set of samples is used as responses for the fit. The reference exposure surfaces mimic the sonic boom exposure at ground level that might be expected in the X-59 survey area in the absence of atmospheric turbulence, ambient noise, and other localized effects. The spatial extent of these surfaces varies and is representative of the different survey area sizes that might be expected during future X-59 community overflight tests. These contrived reference surfaces are sampled, and those reference samples are then perturbed to mimic atmospheric turbulence, ambient noise and other localized effects that might affect noise monitor measurements within overflown communities. Two different surface fitting methods are investigated when fitting these perturbed samples to approximate the reference surface. The first method uses interpolation between the perturbed data at the scattered sites to compute the fit. The second method fits a polynomial surface model to the perturbed data using ordinary least squares regression analysis. For both fitting methods, the root mean square fit error is computed from the pointwise difference between the fit surface and the reference surface as the count and configuration of the sites is varied while also averaging the error across many different realizations of both the smooth variation of the reference exposure surface and the random, localized perturbations at the sample sites. Different site configurations are compared using this error statistic to make the recommendations noted above. Additionally, the two fitting approaches (interpolation vs linear regression) are compared based on the fit error observed in these simulations. These analyses, comparisons, and recommendations should inform future decisions on the noise monitor placement and the methods used to analyze the noise monitor data that is collected during X-59 community overflights.

sonic boom↗

Predictive role of PI-RADSv2 and ADC parameters in differentiating Gleason pattern 3 + 4 and 4 + 3 prostate cancer

Purpose: To compare the predictive roles of qualitative (PI-RADSv2) and quantitative assessment (ADC metrics), in differentiating Gleason pattern (GP) 3 + 4 from the more aggressive GP 4 + 3 prostate cancer (PCa) using radical prostatectomy (RP) specimen as the reference standard. Methods: We retrospectively identified treatment-naïve peripheral (PZ) and transitional zone (TZ) Gleason Score 7 PCa patients who underwent multiparametric 3T prostate MRI (DWI with b value of 0,1400 and where unavailable, 0,500) and subsequent RP from 2011 to 2015. For each lesion identified on MRI, a PI-RADSv2 score was assigned by a radiologist blinded to pathology data. A PI-RADSv2 score ≤ 3 was defined as “low risk,” a PI-RADSv2 score ≥ 4 as “high risk” for clinically significant PCa. Mean tumor ADC (ADC{sub T}), ADC of adjacent normal tissue (ADC{sub N}), and ADC{sub ratio} (ADC{sub T}/ADC{sub N}) were calculated. Stepwise regression analysis using tumor location, ADC{sub T} and ADC{sub ratio}, b value, low vs. high PI-RADSv2 score was performed to differentiate GP 3 + 4 from 4 + 3. Results: 119 out of 645 cases initially identified met eligibility requirements. 76 lesions were GP 3 + 4, 43 were 4 + 3. ADC{sub ratio} was significantly different between the two GP groups (p = 0.001). PI-RADSv2 score (“low” vs. “high”) was not significantly different between the two GP groups (p = 0.17). Regression analysis selected ADC{sub T} (p = 0.03) and ADC{sub ratio} (p = 0.0007) as best predictors to differentiate GP 4 + 3 from 3 + 4. Estimated sensitivity, specificity, and accuracy of the predictive model in differentiating GP 4 + 3 from 3 + 4 were 37, 82, and 66%, respectively. Conclusions: ADC metrics could differentiate GP 3 + 4 from 4 + 3 PCa with high specificity and moderate accuracy while PI-RADSv2, did not differentiate between these patterns.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An adaptive synchronous extraction (ASE) method for estimating intensity and footprint of surface urban heat islands: A case study of 254 North American cities

The urban heat island (UHI) effect has attracted great attention due to its potential impacts on rapidly growing urban areas. Using remotely sensed estimates of land surface temperature (LST), a large number of studies have focused on the surface UHI (SUHI) effect, which can be characterized by its two fundamental properties: intensity and footprint. The SUHI intensity reflects the LST difference between the urban area and the background reference area (BRA), and the SUHI footprint indicates the spatial extent influenced by the heat island. Currently, numerous methods have been developed to estimate the SUHI intensity and footprint, but are still greatly challenged by three main issues. Namely, the discrepancy in BRA selection criterion brings great uncertainty to the estimated SUHI intensity, the estimation of SUHI footprint is largely constrained by the predefined models, and the quantification of SUHI effect is potentially influenced by several confounding factors. Here, we proposed an adaptive synchronous extraction (ASE) method, which is capable of adaptively selecting the most optimal BRA while removing the influence of confounding factors, and achieving synchronous estimation of SUHI intensity and footprint. We applied the ASE method to 254 North American cities and conducted an in-depth comparative analysis to discuss its applicability and benefits. The main results include: (1) The ASE method avoids the limitations of existing methods in BRA selection and model presetting, and shows resilience to parameter variations. This makes the ASE method highly applicable to quantify the SUHI intensity and footprint in cities with various thermal characteristics. (2) The ASE method can better highlight the spatial, seasonal and day-night contrasts in the estimated SUHI intensity. This superiority is particularly evident when comparing it to methods based on the equal-area buffer or the simplified urban-extent algorithm. (3) Confounding factors pose non-negligible impacts on the quantification of the SUHI effect. Typically, ignoring the influence of topographic relief or missing LST data can lead to an overall overestimation of the SUHI intensity, while not removing surrounding urban areas will cause some underestimation of the SUHI intensity. In conclusion, overall, the proposed ASE method provides a new generalizable tool for quantifying the SUHI effect, which has great potentials for future studies and urban climate assessments.

54 ENVIRONMENTAL SCIENCES↗

Independent amplitude approximations in coupled cluster valence bond theory: Incorporation of 3-electron-pair correlation and application to spin frustration in the low-lying excited states of a ferredoxin-type tetrametallic iron-sulfur cluster

We report that coupled cluster valence bond (CCVB) is a simple electronic structure method based on a perfect pairing (PP) reference with 2-pair recouplings for strong electron correlation problems. CCVB is spin-pure, size-consistent, and can exactly (in its active space) separate any molecule into atoms for which unrestricted Hartree-Fock (UHF) at dissociation is the sum of the ground state UHF energies of the atoms. However CCVB is far from a complete description of strong correlations. Its first failure to exactly describe spin-recouplings arises at the level of 3 electron pairs, such as the recoupling of 3 triplet oxygen atoms in the dissociation of singlet ozone. Such situations are often associated with spin frustration. To address this limitation, an extension of CCVB, termed CCVB+i3, is reported here that includes an independent (i) amplitude approximation to the 3-pair recouplings. CCVB+i3 thereby has the same basic computational requirements as those of CCVB, which has previously been shown to be an efficient method. CCVB+i3 correctly separates molecules that CCVB cannot. As a by-product, an independent 2-pair amplitude approximation to CCVB, called PP+i2, is also defined. Remarkably, PP+i2 can also correctly separate systems that CCVB cannot. CCVB+i3 is validated on the symmetric dissociation of D 3h ozone. CCVB+i3 is then used to explore the role of 3-pair recouplings in an [Fe 4 S 4 (SCH 3 ) 4 ] 2- cluster that has been used to model the iron-sulfur core of [Fe 4 S 4 ] ferredoxins. Using localized PP orbitals, such recouplings are demonstrated to be large in some low-lying singlet excited states of the cluster. Lastly, significant 3 pair recoupling amplitudes include the usual triangular motif associated with spin frustration and other geometric arrangements of the 3 entangled pairs across the 4 iron centers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Pathway to a Safe and Effective Medication Formulary for Exploration Spaceflight

PURPOSE: Exploration space missions pose several challenges to providing a comprehensive medication formulary designed to accommodate the size and space limitations of the spacecraft; while addressing the individual medications needs and preferences of the Crew; the negative outcome of a degrading inventory over time, the inability to resupply before expiration dates; and the need to properly forecast the best possible medication candidates to treat conditions that will occur in the future. METHODS: The Pharmacotherapeutics Discipline has partnered with the Exploration Medical Capabilities (ExMC) Element to develop and propose a research pathway that is comprehensively focused on evidence-based models and theories, as well as on new diagnostic tools and treatments or preventive measures aimed at closure of the Med02 “Pharmacy” Gap; defined in the Human Research Program’s (HRP) risk-based research strategy. The Med02 Gap promotes the challenge to identify a strategy to ensure that medications used to treat medical conditions during exploration space missions are available, safe, and effective. It is abundantly clear that pharmaceutical intervention is an essential component of risk management planning for astronaut healthcare during exploration space. However, the quandary still remains of how to assemble a formulary that is comprehensive enough to prevent or treat anticipated medical events; and is also chemically stable, safe, and robust enough to have sufficient potency to last for the duration of an exploration space mission. In cases where that is not possible, addressing this Gap requires exploration of novel drug development techniques, dosage forms, and dosage delivery platforms that enhance chemical stability as well as therapeutic effectiveness. RESULTS: The proposed research pathway outlines the steps, processes, procedures, and a research portfolio aimed at identifying a capability that will provide a safe and effective pharmacy for any specific exploration Design Reference Mission (DRM). The proposed approach to building this research portfolio is to seek research projects that concentrate on four major focus areas; (1) Formulary selection, (2) Formulary potency and shelf life, (3) Formulary safety and toxicity, and (4) Novel technology and innovation such as portable real-time chemical analysis innovative drug therapies and dosage and delivery platforms. CONCLUSION: The research pathway has been completed and presented to the HRP. In spring 2017, it is scheduled to be reviewed by a panel of pharmaceutical and clinical experts that will evaluate the scientific merit and operational feasibility of the research pathway, as well as make suggestions for any warranted additions or improvements. Once finalized, the ExMC Element will proceed with the execution of this research pathway with the goal of gathering as much data, and learning as much as possible, to provide a safe and effective pharmaceutical formulary for use during exploration missions.

Daniels, V. R.↗

Modeling of Glycolate Destruction in the Recycle Collection Tank

The Savannah River Site’s DWPF is being upgraded with the introduction of the NG flowsheet. Glycolic acid has been shown to be a superior alternative to formic acid for sludge processing. The new flowsheet improves or maintains necessary parameters such as 1) reduction of mercury, 2) adjustment of feed rheology, 3) pH stability, and 4) adjustment of melter oxidation/reduction potential. Further, the use of glycolic acid virtually eliminates the potential for catalytic hydrogen generation in DWPF processing DWPF process condensates are collected and returned to the Savannah River Site (SRS) CSTF. The RCT collects off-gas condensate during chemical processing, vitrification, and other unit operations performed in DWPF and is the singular return vessel delivering recycle effluent back to CSTF. Each batch of recycle will have a small amount of glycolate from chemical processing and melter off-gas condensates. To avoid potential flammability issues due to thermolysis of glycolate in the CSTF, Savannah River National Laboratory (SRNL) provided to Savannah River Remediation (SRR) at their request a Task Technical and Quality Assurance Plan (TTQAP) to quantify and mitigate glycolate returns via DWPF’s recycle stream. The request included testing of a process to oxidize glycolate and other organic species that are responsible for hydrogen generation from thermolysis. Following that work SRR provided a Task Technical Request (TTR) that requested process modeling. In 2021 a TTQAP was issued to cover the modeling work. Modeling draws data from laboratory scale studies using chemical simulants and radioactive waste samples. Chemical kinetic modeling was performed to evaluate the feasibility of using sodium permanganate to destroy glycolate in the RCT. The results from the laboratory studies were summarized in a series of reports. Reference 9 is a report of lab scale processing of actual DWPF Slurry Mix Evaporate Condensate Tank (SMECT) and Offgas Condensate Tank (OGCT) samples in the SRNL Shielded Cells. Tests at caustic conditions demonstrated sodium permanganate was effective in converting glycolate to oxalate, and permanganate (Mn 7+ ) is reduced to manganate (Mn 6+ ) with no significant formation of carbon dioxide or carbonate. Equation (1) was found to best describe the observed reaction of glycolate with permanganate under nominal (60 to 145 mg/L in RCT) glycolate entrainment conditions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Analysis of Degradation in Low-Cost Particulate Matter Sensors

Low-cost sensors (LCSs) are increasingly being used to measure fine particulate matter (PM 2.5 ) concentrations in cities around the world. One of the most commonly deployed LCSs is PurpleAir with ∼15 000 sensors deployed in the United States, alone. PurpleAir measurements are widely used by the public to evaluate PM 2.5 levels in their neighborhoods. PurpleAir measurements are also increasingly being integrated into models by researchers to develop large-scale estimates of PM 2.5 . However, the change in sensor performance over time has not been well studied. It is important to understand the lifespan of these sensors to determine when they should be serviced or replaced, and when measurements from these devices should or should not be used for various applications. This paper fills this gap by leveraging the fact that: (1) each PurpleAir sensor is composed of two identical sensors and the divergence between their measurements can be observed, and (2) there are numerous PurpleAir sensors within 50 meters of regulatory monitors allowing for the comparison of measurements between these instruments. We propose empirically-derived degradation outcomes for the PurpleAir sensors and evaluate how these outcomes change over time. On average, we find that the number of ‘flagged’ measurements, where the two sensors within each PurpleAir sensor disagree, increases with time to ∼4% after 4 years of operation. Approximately, 2 percent of all PurpleAir sensors were permanently degraded. The largest fraction of permanently degraded PurpleAir sensors appeared to be in the hot and humid climate zone, suggesting that sensors in these locations may need to be replaced more frequently. We also find that the bias of PurpleAir sensors, or the difference between corrected PM2.5 levels and the corresponding reference measurements, changed over time by −0.12 μg m −3 (95% CI: −0.13 μg m −3 , −0.10 μg m −3 ) per year. The average bias increases dramatically after 3.5 years. Further, climate zone is a significant modifier of the association between degradation outcomes and time.

Priyanka deSouza↗

SMEFT ATLAS: The landscape beyond the Standard Model

The Standard Model Effective Field Theory (SMEFT) based on the unbroken gauge group SU(3) 𝐶 ⊗SU(2) 𝐿 ⊗U(1) 𝑌 and containing only particles of the Standard Model (SM) has developed in the last decade to a mature field. It is the framework to be used in the energy gap from scales sufficiently higher than the electroweak scale up to the lowest energy scale at which new particles show up. We summarize the present status of this theory with a particular emphasize on its role in the indirect search for new physics (NP). While flavour physics of both quarks and leptons is the main topic of our review, we also discuss electric dipole moments, anomalous magnetic moments (𝑔−2) 𝜇,𝑒 , 𝑍-pole observables, Higgs observables and high-𝑝𝑇 scattering processes within the SMEFT. We group the observables into ten classes and list for each class the most relevant operators and the corresponding renormalization group equations (RGEs). We exhibit the correlations between different classes implied both by the operator mixing and the SU(2) 𝐿 gauge symmetry. Our main goal is to provide an insight into the complicated operator structure of this framework which hopefully will facilitate the identification of valid ultraviolet completions behind possible anomalies observed in future data. Numerous colourful charts, and 85 tables, while representing rather complicated RG evolution from the NP scale down to the electroweak scale, beautify the involved SMEFT landscape. Over 1000 references to the literature underline the importance and the popularity of this field. We discuss both top-down and bottom-up approaches as well as their interplay. This allows us eventually to present an atlas of different landscapes beyond the SM that includes heavy gauge bosons and scalars, vector-like quarks and leptons and leptoquarks.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Rationalizing the suitability of rhodamines as chromophores in dye-sensitized solar cells: A systematic molecular design study

Here, rhodamines are chromophores that are employed in many dye applications. Their strong optical absorption in the visible region of the electromagnetic spectrum renders them attractive dye candidates for dye-sensitized solar cells (DSCs). However, they have not yet been systematically tested in DSCs as single- or co-sensitizers. Recent advances in concerted experimental and computational workflows involving molecular design protocols can afford a better understanding of the molecular origins of the optoelectronic properties in these sensitizers. Herein, we examine the suitability of rhodamines R560 (1), R575 (2), R590 (3), R610 (4), R620 (5), R640 (6), and R3B (7) as chromophores in co-sensitized DSCs. Our study follows a stepwise approach. Initially, structural and optical properties of the dyes are investigated by experimental and computational methods to reveal structure-property relationships and other useful features for DSC applications. Subsequently, 1-7 are investigated at the dye···TiO 2 interface, both by calculations of dye-adsorption onto the surface of a modeled (TiO 2 ) 9 cluster, and by experimental studies of dye-adsorption on TiO 2 . For that purpose, a selection of rhodamine dyes are paired together (1 and 5) and (1 and 7) for co-sensitization, among which 5 is also co-adsorbed with a fluorescein dye in order to explore chemical compatibility factors. The best dye candidates are identified from the findings of these adsorption studies in terms of dye aggregation, anchoring modes, and panchromatic response. Despite their promising dye…TiO 2 adsorption and optical prospects, our results show that rhodamines lack a suitable intramolecular charge transfer pathway for dye-to-TiO 2 electron injection to occur, thus precluding their photovoltaic function as DSC dyes. Our results are then assessed against ostensibly disparate reports of rhodamines performing successfully in DSC devices; this comparison necessitated the internal reproduction of previously reported co-sensitization experiments on 2 with the industrial standard reference dye, N3. We achieve reconciliation between our results and those in the literature by reasoning that while rhodamines cannot deliver photovoltaic function in DSCs in their own right, they can either act to facilitate or deplete the photovoltaic output of a DSC indirectly by affecting the TiO 2 adsorption prospects of a photovoltaic-active dye with which a rhodamine is co-sensitized.

14 SOLAR ENERGY↗

G2Aero: A Python package for separable shape tensors

G2Aero is a Python package for the design and deformation of discrete planar curves and tubular surfaces using a geometric data-driven approach. G2Aero utilizes a topology of product manifolds: the Grassmannian, $\mathcal{G}$($\mathcal{n}$, 2) - the set of 2-dimensional subspaces in $\mathbb{R}$ $\mathcal{n}$ - and the symmetric positive-definite (SPD) manifold, $\mathcal{S}^{2}_{++}$ - the set of 2x2 SPD matrices. The package provides a novel framework for representing separable deformations to shapes, which consist of stretching, scaling, rotating, and translating - also known as affine deformations - and a set of complementary deformations - which we refer to as undulation-type deformations. We focus on airfoil and blade design applications to emphasize the utility of the methods in an environment where the separation of affine and undulation-type deformations is critical. Notable functionalities of the framework for blade design include: 1) generating novel 2D (airfoil) shapes informed by a database of physically relevant airfoils, 2) building 3D blades by interpolating sequences of 2D airfoil cross-sections, and 3) generating blades with consistent perturbations along the blade span. We discuss the framework and provide examples in the context of wind energy applications, specifically wind turbine blade design. Figure 1 shows the wire frame obtained by interpolating airfoils defining the IEA 15-MW wind turbine blade and applying affine transformations corresponding to twist, chordal scaling, and bending. This, and all other figures in the paper, can be reproduced following examples and referencing supporting documentation provided in the G2Aero package.

97 MATHEMATICS AND COMPUTING↗