Search NASA⌕ Search

SEARCH · Search NASA

Results for “SWEEP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Effect of electron cyclotron resonance ion source frequency tuning on ion beam intensity and quality at Department of Physics, University of Jyvaeskylae

Ion beam intensity and quality have a crucial effect on the operation efficiency of the accelerator facilities. This paper presents the investigations on the ion beam intensity and quality after the mass separation performed with the Department of Physics, University of Jyvaeskylae 14 GHz electron cyclotron resonance ion source by sweeping the microwave in the 14.05-14.13 GHz range. In many cases a clear variation in the ion beam intensity and quality as a function of the frequency was observed. The effect of frequency tuning increased with the charge state. In addition, clear changes in the beam structure seen with the beam viewer were observed. The results confirmed that frequency tuning can have a remarkable effect on ion beam intensity and quality especially in the case of highly charged ion beams. The examples presented here represent the typical charge state behavior observed during the measurements.

43 PARTICLE ACCELERATORS↗

A wireless interrogation system exploiting narrowband acoustic resonator for remote physical quantity measurement

Monitoring physical quantities using acoustic wave devices can be advantageously achieved using the wave characteristic dependence to various parametric perturbations (temperature, stress, and pressure). Surface acoustic wave (SAW) resonators are particularly well suited to such applications as their resonance frequency is directly influenced by these perturbations, modifying both the phase velocity and resonance conditions. Moreover, the intrinsic radio frequency (rf) nature of these devices makes them ideal for wireless applications, mainly exploiting antennas reciprocity and piezoelectric reversibility. In this paper, we present a wireless SAW sensor interrogation unit operating in the 434 MHz centered ISM band--selected as a tradeoff between antenna dimensions and electromagnetic wave penetration in dielectric media--based on the principles of a frequency sweep network analyzer. We particularly focus on the compliance with the ISM standard which reveals complicated by the need for switching from emission to reception modes similarly to radar operation. In this matter, we propose a fully digital rf synthesis chain to develop various interrogation strategies to overcome the corresponding difficulties and comply with the above-mentioned standard. We finally assess the reader interrogation range, accuracy, and dynamics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of multipactor conditioning on technical electrode surfaces

Historically, multipactor conditioning has been utilized to remove surface contaminants from rf electrodes by electron-stimulated gas desorption, and such conditioning has been shown to reduce multipactor susceptibility. Multipactor threshold improvements are due to increasing E{sub 1}, the minimum energy for the secondary electron coefficient, {delta}>1, such that resonant electrons are incapable of producing discharge-sustaining secondary emission. Using an rf amplitude sweep technique, the evolution of the multipactor threshold is measured as a function of multipactor conditioning time for a series of technical electrode surfaces. Results show over +3 dB of threshold improvement in copper and gold electrodes, while the aluminum threshold actually decreases with conditioning exposure. Additionally, these conditioning results indicate the possible voltage region for transient-mode multipaction (TMM), which can cause significant risk to rf systems such as space satellite components for which in-situ conditioning is generally not possible. Experimental results and supporting Monte Carlo particle tracking simulation results are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A grazing incidence x-ray streak camera for ultrafast, single-shot measurements

An ultrafast x-ray streak camera has been realized using a grazing incidence reflection photocathode. X-rays are incident on a gold photocathode at a grazing angle of 20 degree and photoemitted electrons are focused by a large aperture magnetic solenoid lens. The streak camera has high quantum efficiency, 600fs temporal resolution, and 6mm imaging length in the spectral direction. Its single shot capability eliminates temporal smearing due to sweep jitter, and allows recording of the ultrafast dynamics of samples that undergo non-reversible changes.

36 MATERIALS SCIENCE↗

Evaluation of ion collection area in Faraday probes

A Faraday probe with three concentric rings was designed and fabricated to assess the effect of gap width and collector diameter in a systematic study of the diagnostic ion collection area. The nested Faraday probe consisted of two concentric collector rings and an outer guard ring, which enabled simultaneous current density measurements on the inner and outer collectors. Two versions of the outer collector were fabricated to create gaps of 0.5 and 1.5 mm between the rings. Distribution of current density in the plume of a low-power Hall thruster ion source was measured in azimuthal sweeps at constant radius from 8 to 20 thruster diameters downstream of the exit plane with variation in facility background pressure. A new analytical technique is proposed to account for ions collected in the gap between the Faraday probe collector and guard ring. This method is shown to exhibit excellent agreement between all nested Faraday probe configurations, and to reduce the magnitude of integrated ion beam current to levels consistent with Hall thruster performance analyses. The technique is further studied by varying the guard ring bias potential with a fixed collector bias potential, thereby controlling ion collection in the gap. Results are in agreement with predictions based on the proposed analytical technique. The method is applied to a past study comparing the measured ion current density profiles of two Faraday probe designs. These findings provide new insight into the nature of ion collection in Faraday probe diagnostics, and lead to improved accuracy with a significant reduction in measurement uncertainty.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Visible Light Diagnostics at SPEAR3

The visible light diagnostic beam line at SPEAR3 utilizes dipole radiation extracted through an ID exit port to evaluate electron beam properties at a variety of diagnostic end-stations. The unfocused SR light is collected 17 m from the source point by a 150 mm diameter, f = 2 m lens and optically relayed to the appropriate station. For transverse imaging, an image-intensified PiMax camera with 2 ns gate allows measurement of fast beam dynamics for either the stored beam or the injected beam. For these applications the visible light is switched into either a standard symmetric-lens transport line or a beam-shaping transport line equipped with cylindrical lenses and a rotating mirror to sweep the beam image across the camera photocathode. A separate two slit stellar-interferometer branch line can resolve the diffraction-limited vertical beam height down to about 10 {mu}m. For longitudinal charge profile measurements, the light is switched to a Hamamatsu C5680 streak camera with net system resolution of {approx}2.5 ps rms. In this paper we outline the main photon beam transport line, review the SR beam properties and describe measurement capabilities at each diagnostic station.

43 PARTICLE ACCELERATORS↗

Advances in Time Resolved X-ray Excited Optical Luminescence Instrumentation at the Canadian Light Source

Measurement of the optical emission properties of samples excited by x-rays can be used to study defect states in crystals and the optical properties of nanostructured materials. Changes in the intensities, wavelengths and lifetimes of the optical emission can occur when specific core level electrons are excited using tuneable light from a synchrotron light source. At the Canadian Light Source (CLS), collaboration between the user community, the experimental facilities group and the accelerator division has resulted in improved capabilities in the acquisition of Time Resolved XEOL (TRXEOL) data. Using a streak camera, the optical luminescence decay curves from samples excited with 35 ps long synchrotron pulses have been obtained. The streak tube is operated in single sweep mode and is triggered by the 500 MHz RF signal, which has been resynchronized to the orbit clock frequency giving a highly stable trigger pulse. A transverse kicker system is used to improve bunch purity from 10{sup 2} to 10{sup 6}. The decay curves of the XEOL of nanostructured ZnO and a high pressure form of SiO{sub 2} have been measured and demonstrate the unique capabilities of this instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Random walk of magnetic field lines in dynamical turbulence: A field line tracing method. I. Slab turbulence

To study the wandering of magnetic field lines is an important subject in theoretical physics. Results of field line random walk theories can be applied in plasma physics as well as astrophysics. Previous investigations are based on magnetostatic models. These models have been used in analytical work as well as in computer simulations to warrant mathematical and numerical tractability. To replace the magnetostatic model by a dynamical turbulence model is a difficult task. In the present article, a field line tracing method is used to describe field line wandering in dynamical magnetic turbulence. As examples different models are employed, namely, the plasma wave model, the damping model of dynamical turbulence, and the random sweeping model. It is demonstrated that the choice of the turbulence model has a very strong influence on the field line structure. It seems that if dynamical turbulence effects are included, Markovian diffusion can be found for other forms of the wave spectrum as in the magnetostatic model. Therefore, the results of the present paper are useful to specify turbulence models. As a further application we consider charged particle transport at early times.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Heavy ion beam probe operation in time varying equilibria of improved confinement reversed field pinch discharges

Operation of a heavy ion beam probe (HIBP) on a reversed field pinch is unique from other toroidal applications because the magnetic field is more temporal and largely produced by plasma current. Improved confinement, produced through the transient application of a poloidal electric field which leads to a reduction of dynamo activity, exhibits gradual changes in equilibrium plasma quantities. A consequence of this is sweeping of the HIBP trajectories by the dynamic magnetic field, resulting in motion of the sample volume. In addition, the plasma potential evolves with the magnetic equilibrium. Measurement of the potential as a function of time is thus a combination of temporal changes of the equilibrium and motion of the sample volume. A frequent additional complication is a nonideal balance of ion current on the detectors resulting from changes in the beam trajectory (magnetic field) and energy (plasma potential). This necessitates use of data selection criteria. Nevertheless, the HIBP on the Madison Symmetric Torus has acquired measurements as a function of time throughout improved confinement. A technique developed to infer the potential in the improved confinement reversed field pinch from HIBP data in light of the time varying plasma equilibrium will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interpretation and implementation of an ion sensitive probe as a plasma potential diagnostic

An ion sensitive probe (ISP) is developed as a robust diagnostic for measuring plasma potentials ({Phi}{sub P}) in magnetized plasmas. The ISP relies on the large difference between the ion and electron gyroradii ({rho}{sub i}/{rho}{sub e}{approx}60) to reduce the electron collection at a collector recessed behind a separately biased wall distance {approx}{rho}{sub i}. We develop a new ISP method to measure the plasma potential that is independent of the precise position and shape of the collector. {Phi}{sub P} is found as the wall potential when charged current to the probe collector vanishes during the voltage sweep. The plasma potentials obtained from the ISP match {Phi}{sub P} measured with an emissive probe over a wide range of plasma conditions in a small magnetized plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Potential measurements with heavy ion beam probe system on LHD

The heavy ion beam probe system in the Large Helical Device (LHD) was improved as follows. At first, the additional new sweeper was installed into the diagnostic port to extend the observable region. By using this sweeper, the potential profile was measured in a wider minor radius range than in previous experiments, in the case of outward shifted magnetic configuration of LHD. Next, the real time control system was installed to control the probe beam orbit for measuring the potential in plasma with large plasma current. In this system, a digital signal processor was used to control the probe beam in real time. The system worked well in the fixed position observation mode. In the sweeping mode for profile measurement, this control system became unstable. The details of this system and the experimental results are reported in this article.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparative electron temperature measurements of Thomson scattering and electron cyclotron emission diagnostics in TCABR plasmas

We present the first simultaneous measurements of the Thomson scattering and electron cyclotron emission radiometer diagnostics performed at TCABR tokamak with Alfven wave heating. The Thomson scattering diagnostic is an upgraded version of the one previously installed at the ISTTOK tokamak, while the electron cyclotron emission radiometer employs a heterodyne sweeping radiometer. For purely Ohmic discharges, the electron temperature measurements from both diagnostics are in good agreement. Additional Alfven wave heating does not affect the capability of the Thomson scattering diagnostic to measure the instantaneous electron temperature, whereas measurements from the electron cyclotron emission radiometer become underestimates of the actual temperature values.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of the Li beam probe with a beam profile monitor on JET

The lithium beam probe (LBP) is widely used for measurements of the electron density in the edge plasma of magnetically confined fusion experiments. The quality of LBP data strongly depends on the stability and profile shape of the beam. The main beam parameters are as follows: beam energy, beam intensity, beam profile, beam divergence, and the neutralization efficiency. For improved monitoring of the beam parameters, a beam profile monitor (BPM) from the National Electrostatics Corporation (NEC) has been installed in the Li beam line at JET. In the NEC BPM, a single grounded wire formed into a 45 deg. segment of a helix is rotated by a motor about the axis of the helix. During each full revolution, the wire sweeps twice across the beam to give X and Y profiles. In this paper, we will describe the properties of the JET Li beam as measured with the BPM and demonstrate that it facilitates rapid optimization of the gun performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiband reflectometry system for density profile measurement with high temporal resolution on JET tokamak

A new system has been installed on the JET tokamak consisting of six independent fast-sweeping reflectometers covering four bands between 44 and 150 GHz and using orthogonal polarizations. It has been designed to measure density profiles from the plasma edge to the center, launching microwaves through 40 m of oversized corrugated waveguides. It has routinely produced density profiles with a maximum repetition rate of one profile every 15 {mu}s and up to 100 000 profiles per pulse.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A numerical method for determining highly precise electron energy distribution functions from Langmuir probe characteristics

Electron energy distribution functions (EEDFs) were determined from probe characteristics using a numerical ac superimposed method with a distortion correction of high derivative terms by varying amplitude of a sinusoidal perturbation voltage superimposed onto the dc sweep voltage, depending on the related electron energy. Low amplitude perturbation applied around the plasma potential represented the low energy peak of the EEDF exactly, and high amplitude perturbation applied around the floating potential was effective to suppress noise or distortion of the probe characteristic, which is fatal to the tail electron distribution. When a small random noise was imposed over the stabilized prove characteristic, the numerical differentiation method was not suitable to determine the EEDF, while the numerical ac superimposed method was able to obtain a highly precise EEDF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Axisymmetric oscillation modes of a double droplet system

A double droplet system (DDS) consists of a sessile and a pendant drop that are coupled through a liquid filled cylindrical hole in a plate of thickness d. For a small hole radius R, equilibrium shapes of both drops are sections of spheres. While DDSs have a number of applications in microfluidics, a DDS oscillating about its equilibrium state can be used as a fast focusing liquid lens. Here, a DDS consisting of an isothermal, incompressible Newtonian fluid of constant density p and constant viscosity u that is surrounded by a gas is excited by oscillating in time (a) the pressure in the gas surrounding either drop (pressure excitation), (b) the plate perpendicular to its plane (axial excitation), and (c) the hole radius (radial excitation). In contrast to previous works that assumed transient drop shapes are spherical, they are determined here by simulation and used to identify the natural modes of axisymmetric oscillations from resonances observed during frequency sweeps with DDSs for which the combined volume V of the two drops is less than (4/3)πR 3 . Pressure and axial excitations are found to have identical responses but axial and radial excitations are shown to excite different modes. These modes are compared to those exhibited by single pendant (sessile) drop systems. Specifically, while a single pendant (sessile) drop has one additional oscillation mode compared to a free drop, a DDS is found to exhibit roughly twice as many oscillation modes as a pendant (sessile) drop. The effects of dimensionless volume V/R 3 , dimensionless plate thickness d/R, and Ohnesorge number Oh =μ/√ρRσ , where σ is the surface tension of the DDS-gas interface, on the resonance frequencies are also investigated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Determination of radial location of rotating magnetic islands by use of poloidal soft x-ray detector arrays in the STOR-M tokamak

A technique is presented for determining the radial location of the rotating magnetic islands in the STOR-M tokamak by use of soft x-ray (SXR) detector arrays. The location is determined by examining the difference in the integrated SXR emission intensities through two adjacent lines of sight. A model for calculating dependence of the line integrated SXR emission intensity on the radius, the mode numbers and the magnetic island geometry, has been developed. The SXR difference signal shows phase inversion when the impact parameter of the line of sight sweeps across the magnetic islands. Experimentally, the difference SXR signals significantly reduce noise and suppress the influence of background plasma fluctuations through common mode rejection when a dominant mode exists in the STOR-M tokamak. The radial locations of the m= 2 magnetic islands have been determined under several experimental conditions in the STOR-M discharges. With the decrease in the tokamak discharge current and thus the increase of the safety factor at the edge, the radial location of the m= 2 magnetic islands has been found to move radially inward.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synchronous (Lock-in) Measurement Techniques for Magnetic Contrast Enhancement in STXM

We have explored the capabilities of synchronous ('lock-in') point detection techniques to enhance the x-ray magnetic circular dichroism (XMCD) contrast in scanning x-ray transmission microscopy (STXM) of magnetic thin-film microstructures. Local absorption contrast, measured synchronously with low-amplitude (<10 Oe) and low-frequency (<200 hz) longitudinal fields perturbing the near-remanent magnetization state, reveal a strong spatial dependence of the response, with a roll-off in frequency response above 200 Hz. In this context, synchronous measurement affords us a basis for imaging the relation between energy loss and the sweeping rate. We speculate that the lock-in approach will be uniquely suited for detailing stochastic and deterministic frequency-dependent events in the process of magnetization reversal.

36 MATERIALS SCIENCE↗