Pufferscale: Rescaling HPC Data Services for High Energy Physics Applications

User-space HPC data services are emerging as an appealing alternative to traditional parallel file systems, because of their ability to be tailored to application needs while eliminating unnecessary overheads incurred by POSIX compliance. The High Energy Physics (HEP) community is progressively turning towards such services to enable high-throughput accesses under heavy concurrency to billions of event data produced by instruments and consumed by subsequent analysis workflows. Such services would benefit from the possibility to be rescaled up and down to adapt to changing workloads, as experimental campaigns progress, in order to optimize resource usage. This paper formalizes rescaling a distributed storage system as a multi objective optimization problem considering three criteria: load balance, data balance, and duration of the rescaling operation. We propose a heuristic for rapidly finding a good approximate solution, while allowing users to weight the criteria as needed. The heuristic is evaluated with Pufferscale, a new rescaling manager for microservice-based distributed storage systems. To validate our approach in a real-world ecosystem, we showcase the use of Pufferscale as a means to enable storage malleability in the HEPnOS storage system for HEP applications.

Distributed Storage System↗

Baseline Testing of the Club Car Carryall With Asymmetric Ultracapacitors

The NASA John H. Glenn Research Center initiated baseline testing of the Club Car Carryall with asymmetric ultracapacitors as a way to reduce pollution in industrial settings, reduce fossil fuel consumption, and reduce operating costs for transportation systems. The Club Car Carryall provides an inexpensive approach to advance the state of the art in electric vehicle technology in a practical application. The project transfers space technology to terrestrial use via non-traditional partners, and provides power system data valuable for future space applications. The work was done under the Hybrid Power Management (HPM) Program, which includes the Hybrid Electric Transit Bus (HETB). The Carryall is a state of the art, ground up, electric utility vehicle. A unique aspect of the project was the use of a state of the art, long life ultracapacitor energy storage system. Innovative features, such as regenerative braking through ultracapacitor energy storage, are planned. Regenerative braking recovers much of the kinetic energy of the vehicle during deceleration. The Carryall was tested with the standard lead acid battery energy storage system, as well as with an asymmetric ultracapacitor energy storage system. The report concludes that the Carryall provides excellent performance, and that the implementation of asymmetric ultracapacitors in the power system can provide significant performance improvements.

Eichenberg, Dennis J.↗

XRootD Third Party Copy for the WLCG and HLLHC

A Third Party Copy (TPC) mechanism has existed in the pure XRootD storage environment for many years. However, using the XRootD TPC in the WLCG environment presents additional challenges due to the diversity of the storage systems involved such as EOS, dCache, DPM and ECHO, requiring that we carefully navigate the unique constraints imposed by these storage systems and their site-specific environments through customized configuration and software development. To support multitenant setups seen at many WLCG sites, X509 based authentication and authorization in XRootD was significantly improved to meet both security and functionality requirements. This paper presents architecture of the pull based TPC with optional X509 credential delegation, and how it is implemented in native XRootD and dCache. The paper discusses technical requirements, challenges, design choices and implementation details in the WLCG storage systems, as well as in FTS/gfal2. It also outlines XRootD’s plan to support newer TPC and security models such as token based authorization.

Adye, T.↗

XRootD Third Party Copy for the WLCG and HL- LHC

A Third Party Copy (TPC) mechanism has existed in the pure XRootD storage environment for many years. However, using the XRootD TPC in the WLCG environment presents additional challenges due to the diversity of the storage systems involved such as EOS, dCache, DPM and ECHO, requiring that we carefully navigate the unique constraints imposed by these storage systems and their site-specific environments through customized configuration and software development. To support multitenant setups seen at many WLCG sites, X509 based authentication and authorization in XRootD was significantly improved to meet both security and functionality requirements. This paper presents architecture of the pull based TPC with optional X509 credential delegation, and how it is implemented in native XRootD and dCache. The paper discusses technical requirements, challenges, design choices and implementation details in the WLCG storage systems, as well as in FTS/gfal2. It also outlines XRootD's plan to support newer TPC and security models such as token based authorization. 1

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Enabling High Availability Service with oVirt Virtualization and CephFS

The online computing environment at STAR has generated demand for high availability of services (HAS) and a resilient uptime guarantee. Such services include databases, webservers, and storage systems that user and sub-systems tend to rely on for their critical workflows. Standard deployment of services on bare metal creates a problem if the fundamental hardware fails or loses connectivity. Additionally, the configuration of redundant failover nodes (a secondary Web service for example) requires constant syncing of configuration and content and sometimes manual interaction for switching hardware (DNS name comes to mind). For this project, we will focus on two tools: oVirt and Ceph. oVirt is an OpenSource virtualization management application that enables central management of hardware nodes, storage, and network resources used to deploy and monitor virtual machines. oVirt supports the deployment of a virtual environment for your data center leveraging automatic provisioning, live migration, and the ability to easily scale the number of hypervisors. oVirt enables the use of multiple storage technologies where you can store virtual machines, images, and templates within one or multiple storage systems. STAR's recent efforts focused on deploying a CephFS POSIX compliant distributed storage system, we would enable the ability to couple our Ceph storage with the oVirt virtualization management system. When designing an intricate system for hosting critical services, it is a requirement to circumvent single points of failure. This work will involve the testing and viability of such an approach along with test cases for high availability, live migration, and service on demand.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Co-optimized trading of hybrid wind power plant with retired EV batteries in energy and reserve markets under uncertainties

To be competitive in the electricity markets, various technologies have been reported to increase profits of wind farm owners. Combining battery storage system, wind farms can be operated as conventional power plants which promotes the integration of wind power into the power grid. However, high expenses on batteries keep investors away. Retired EV batteries, fortunately, still have enough capacity to be reused and could be obtained at a low price. In this work, a two-stage optimization of a wind energy retired EV battery-storage system is proposed. The economic performance of the proposed system is examined concerning its participation in the frequency containment normal operation reserve (FCR-N) market and the spot market simultaneously. To account uncertainties in the wind farm output, various electricity market prices, and up/down regulation status, a scenario-based stochastic programming method is used. The sizing of the equipment is optimized on top of daily operations of the hybrid system which formulates a mixed-integer linear programming (MILP) problem. Scenarios are generated with the Monte Carlo simulation (MCS) and Roulette Wheel Mechanism (RWM), which are further reduced with the simultaneous backward method (SBM) to increase computational efficiency. A 21 MW wind farm is selected as a case study. Here, the optimization results show that by integrating with a retired EV battery-storage system (RESS) and a bi-directional inverter, the wind farm can increase its profits significantly when forwarding bids in both of the aforementioned electricity markets.

17 WIND ENERGY↗

Upper Atmosphere Research Satellite (UARS) trade analysis

The Upper Atmosphere Research Satellite (UARS) which will collect data pertinent to the Earth's upper atmosphere is described. The collected data will be sent to the central data handling facility (CDHF) via the UARS ground system and the data will be processed and distributed to the remote analysis computer systems (RACS). An overview of the UARS ground system is presented. Three configurations were developed for the CDHF-RACS system. The CDHF configurations are discussed. The IBM CDHF configuration, the UNIVAC CDHF configuration and the vax cluster CDHF configuration are presented. The RACS configurations, the IBM RACS configurations, UNIVAC RACS and VAX RACS are detailed. Due to the large on-line data estimate to approximately 100 GB, a mass storage system is considered essential to the UARS CDHF. Mass storage systems were analyzed and the Braegan ATL, the RCA optical disk, the IBM 3850 and the MASSTOR M860 are discussed. It is determined that the type of mass storage system most suitable to UARS is the automated tape/cartridge device. Two devices of this type, the IBM 3850 and the MASSTOR MSS are analyzed and the applicable tape/cartridge device is incorporated into the three CDHF-RACS configurations.

Fox, M. M.↗

Using Encapsulated Phase Change Material in Thermal Storage for Baseload Concentrating Solar Power Plants

Terrafore successfully demonstrated and optimized the manufacturing of capsules containing phase-changing inorganic salts. The phase change was used to store thermal energy collected from a concentrating solar-power plant as latent heat. This latent heat, in addition to sensible heat increased the energy density (energy stored per unit weight of salt) by over 50%, thus requiring 40% less salt and over 60% less capsule container. Therefore, the cost to store high-temperature thermal energy collected in a concentrating solar power plant will be reduced by almost 40% or more, as compared to conventional two-tank, sensible-only storage systems. The cost for thermal energy storage (TES) system is expected to achieve the Sun Shot goal of $\$ $15 per kWh(t). Costs associated with poor heat-transfer in phase change materials (PCM) were also eliminated. Although thermal energy storage that relies on the latent heat of fusion of PCM improves energy density by as much as 50%, upon energy discharge the salt freezes and builds on the heat transfer surfaces. Since these salts have low thermal conductivity, large heat-transfer areas, or larger conventional heat-exchangers are needed, which increases costs. By encapsulating PCM in small capsules we have increased the heat transfer area per unit volume of salt and brought the heat transfer fluid in direct contact with the capsules. These two improvements have increased the heat transfer coefficient and boosted heat transfer. The program was successful in overcoming the phenomenon of melt expansion in the capsules, which requires the creation of open volume in the capsules or shell to allow for expansion of the molten salt on melting and is heated above its melting point to 550°C. Under contract with the Department of Energy, Terrafore Inc. and Southwest Research Institute, developed innovative method(s) to economically create the open volume or void in the capsule. One method consists of using a sacrificial polymer coating as the middle layer between the salt prill and the shell material. The selected polymer decomposes at temperatures below the melting point of the salt and forms gases which escape through the pores in the capsule shell thus leaving a void in the capsule. We have demonstrated the process with a commonly used inorganic nitrate salt in a low-cost shell material that can withstand over 10,000 high-temperature thermal cycles, or a thirty-year or greater life in a solar plant. The shell used to encapsulate the salt was demonstrated to be compatible with molten salt heat transfer fluid typically used in CSP plants to temperatures up to 600 °C. The above findings have led to the concept of a cascaded arrangement. Salts with different melting points can be encapsulated using the same recipe and contained in a packed bed by cascading the salt melting at higher melting point at the top over the salt melting at lower melting point towards the bottom of the tank. This cascaded energy storage is required to effectively transfer the sensible heat collected in heat transfer fluids between the operating temperatures and utilize the latent heat of fusion in the salts inside the capsule. Mathematical models indicate that over 90% of the salts will undergo phase change by using three salts in equal proportion. The salts are selected such that the salt at the top of the tank melts at about 15°C below the high operating-temperature, and the salt at the bottom of the tank melts 15°C above the low operating-temperature. The salt in the middle of tank melts in-between the operating temperature of the heat transfer fluid. A cascaded arrangement leads to the capture of 90% of the latent-heat of fusion of salts and their sensible heats. Thus the energy density is increased by over 50% from a sensible-only, two-tank thermal energy storage. Furthermore, the Terrafore cascaded storage method requires only one tank as opposed to the two-tanks used in sensible heat storage. Since heat is transferred from the heat transfer fluid by direct contact with capsules, external heat-exchangers are not required for charging storage. Thus, the cost of the thermal storage system is reduced due to smaller containers and less salt. The optimum salt proportions, their melting temperature and the number of salts in the cascade are determined by raw materials costs and the mathematical model. We estimate the processing cost of the encapsulation to be low, where the major cost of the capsule will be the cost of the phase-change salt(s). Our economic analyses show that the cost of EPCM-TES is about $\$ $17.98 per kWh(t), which is about 40% lower than the $\$ $28.36 per kWh(t) for a two-tank sensible heat TES for a large scale CSP-TES design. Finally, additional improvements in the heat-transfer fluids, currently in development elsewhere will further improve the energy density to achieve the SunShot goal of $\$ $15 per kWh(t).

14 SOLAR ENERGY↗

Test report :

The Department of Energy Office of Electricity (DOE/OE), Sandia National Laboratory (SNL) and the Base Camp Integration Lab (BCIL) partnered together to incorporate an energy storage system into a microgrid configured Forward Operating Base to reduce the fossil fuel consumption and to ultimately save lives. Energy storage vendors will be sending their systems to SNL Energy Storage Test Pad (ESTP) for functional testing and then to the BCIL for performance evaluation. The technologies that will be tested are electro-chemical energy storage systems comprised of lead acid, lithium-ion or zinc-bromide. Princeton Power Systems has developed an energy storage system that utilizes lithium ion phosphate batteries to save fuel on a military microgrid. This report contains the testing results and some limited analysis of performance of the Princeton Power Systems Prototype Energy Storage System.

Rose, David Martin↗

Co-design optimization of combined heat and power-based microgrids

With the emergent need for clean and reliable energy resources, hybrid energy systems, such as the microgrid, are widely adopted in the United States. A microgrid can consist of various distributed energy resources, for instance, combined heat and power (CHP) systems. Here, the CHP module is a distributed cogeneration technology that produces electricity and recaptures heat generated as a by-product. It is an energy-efficient technology converting heat that would otherwise be wasted to valuable thermal energy. For an optimal system configuration, this study develops a novel co-design optimization framework for CHP-based cogeneration microgrids. The framework provides the stakeholder with a method to optimize investments and attain resilient operations. The proposed co-design framework has a mixed integer programming (MIP) model that outputs decisions for both plant designs and operating controls. The microgrid considered in this study contains six components: the CHP, boiler, heat recovery unit, thermal storage system, power storage system, and photovoltaic plant. After solving the MIP model, the optimal design parameters of each component can be found to minimize the total installation cost of all components in the microgrid. Furthermore, the online costs from energy production, operation, maintenance, machine startup, and disruption-induced unsatisfied loads are minimized by solving the optimal control decisions for operations. Case studies based on designing a CHP-based microgrid with empirical data are conducted. Moreover, we consider both nominal and disruptive operational scenarios to validate the performance of the proposed co-design framework in terms of a cost-effective, resilient system.

42 ENGINEERING↗

Chloride-Induced Stress Corrosion Cracking Characteristics of the Used Nuclear Fuel Canister Material

The used nuclear fuel (UNF) dry storage systems are located in the coastal and lake/river-side regions, the service time of which is 60 years and more. One type of dry storage systems is composite of a thin-walled austenitic stainless steel (SS) welded canister and a concrete overpack. The air flows through the canister surface and brings away the decay heat. Meanwhile, the air brings the salt species into the canister and make them deposit on the surface. The salt deposit will be deliquescent when absorbing the moisture air, being corrosive to the surface. NRC and other programs claimed that chloride induced stress corrosion cracking (CISCC) would lead to the canister failure, being one of the major technical gaps for extended dry storage systems. CISCC is induced by the combined influence of the aggressive environment (chloride ions in our case) and tensile stresses (residual stresses in our case) on the susceptible materials (the austenitic SS in our case). Chrome (Cr), as one of the chemical compositions of SSs, plays an important role in the corrosion resistance. It can form a chrome-rich inner barrier oxide layer to prevent the SS from corrosion. However, chloride ions can easily break down the barrier and accelerate dissolution of the underlying metal, the phenomena of which is pitting corrosion. Pitting is the precursor to CISCC as which provides the combination of a local aggressive solution chemistry and a stress concentrating feature. Accordingly, CISCC invariably originates from the pits, and cracks that have nucleated on pit walls can grow around the pit and coalesce to form a complete through-crack. Significant tensile residual stresses, caused by the welding process, exist throughout the thickness of the canister wall. Enos and Bryan found that large residual stresses were in the full-scale mockup container simulating a canister, which supports the SCC propagation. It is therefore interesting to achieve a good knowledge about the effect of welding on the durability of SSs, especially in the corrosive environment. In order to understand the fundamental of the cracking behaviors, it's vital to elucidate the microstructure and microchemistry of cracking. This study focused on observing the CISCC characteristics of the UNF canister material exposed to the humid environment with salt deposit. Extensive micro-characteristics have been achieved by the techniques include focused ion beam/ scanning electron microscope (FIB/SEM), transmission electron microscopy (TEM), energy dispersive spectroscopy (EDS), and optical profiler. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Volumetrics of Hydrogen Storage by Physical Adsorption

Physical adsorption remains a promising method for achieving fast, reversible hydrogen storage at both ambient and cryogenic conditions. Research in this area has recently shifted to focus primarily on the volumetric (H 2 stored/delivered per volume) gains achieved within an adsorptive storage system over that of pure H 2 compression; however, the methodology for estimating a volumetric stored or delivered amount requires several assumptions related to the ultimate packing of the adsorbent material into an actual storage system volume. In this work, we critically review the different assumptions commonly employed, and thereby categorize and compare the volumetric storage and delivery across numerous different porous materials including benchmark metal-organic frameworks, porous carbons, and zeolites. In several cases, there is a significant gain in both storage and delivery by the addition of an adsorbent to the high-pressure H 2 storage system over that of pure compression, even at room temperature. Lightweight, low-density materials remain the optimal adsorbents at low temperature, while higher density, open metal-containing frameworks are necessary for high-density room temperature storage and delivery.

08 HYDROGEN↗

It’s Time to Talk About HPC Storage: Perspectives on the Past and Future

High-performance computing (HPC) storage systems are a key component of the success of HPC to date. Recently, we have seen major developments in storage-related technologies, as well as changes to how HPC platforms are used, especially in relation to artificial intelligence and experimental data analysis workloads. Additionally, these developments merit a revisit of HPC storage system architectural designs. In this article, we discuss the drivers, identify key challenges to status quo posed by these developments, and discuss directions future research might take to unlock the potential of new technologies for the breadth of HPC applications.

97 MATHEMATICS AND COMPUTING↗

Demonstration of Power System Black Start with Hydropower Generator and Battery Energy Storage: Preprint

Battery energy storage systems (BESS) are an important asset for power systems with high integration levels of renewable energy, and they can be controlled to provide various services to the grid. This paper presents the hardware demonstration and characterization of using a utility-scale BESS with grid-following (GFL) and grid-forming (GFM) controls and a run-of-river (ROR) hydropower plant to perform a bottom-up power system black start that enhances power systems' resiliency. ROR hydropower plants are generally not used for power system restoration due to their frequency instability during islanded operation; however, BESS with droop control can provide critical damping to convert a ROR hydropower generator into a blackstart- capable unit. To demonstrate this, we carry out hardware experiments at the megawatt-scale integrating a synchronous generator driven by a dynamometer, an actual GFL/GFM BESS, a medium-voltage impedance network, and a load bank. The demonstration shows the different roles of BESS with GFL and GFM control in power system restoration. GFL BESS can suffer from high-frequency oscillations, even instability, depending on the droop control gain and loading condition. The results provide further insights for system operators on how GFL- or GFMcontrolled BESS can enhance grid stability and how hydro-BESS hybrids can operate as a black-start-capable unit. The presented experimental results are also a valuable resource to understand the different stability characteristics of real-world BESS with different control modes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

THERMAL MODELING OF HANFORD CESIUM AND STRONTIUM CANISTERS DURING SIMULATED LOADING

A computational fluid dynamics (CFD) model was built to simulate planned testing of heater assemblies within a canister and overpack for the Hanford Lead Canister (HLC) project. The HLC is a canister storage system that will contain heaters to simulate the decay heat of nuclear material and provide the canister storage system with environmental conditions equivalent to the operating conditions on a dry storage pad. The HLC will be equipped with long-term data collection and monitoring systems to provide an early warning of corrosion, pitting, cracking, or other signs of canister degradation that might threaten the integrity of the containment boundary over the potentially long term of dry storage. An important part of the HLC development is to make pretest numerical predictions for the behavior of the heated canister during the simulated radiolytic decay heat testing, which simulates the dry storage system during loading operations. The simulated radiolytic decay heat test is planned for mid-2024 in a configuration that includes the heater assembly, overpack, and canister, but with the lids removed to allow loading cesium and strontium capsules into the canister. One of the goals of the test is to evaluate the thermal behavior of the canister and overpack assembly in the ambient air of the test facility, which will provide data critical to validating the thermal models and understanding how the HLC will perform as a system once deployed. To best approximate real-world conditions, the CFD model includes the full air volume of the mock-up truck bay the heated canister test will be performed in, enabling detailed investigation of how the heated canister affects airflow around it. Rigorous pre-deployment testing of the complete HLC cask and canister system is intended to be completed before the HLC is deployed in the 2028 timeframe. This study presents the pre-test temperature predictions of the simulated radiolytic decay heat test. A description of the heater assembly, canister, and overpack system is presented. The model was developed with the commercial CFD software STAR-CCM+. An uncertainty analysis was run with the CFD model to determine the uncertainty in the temperature predictions and provide a range over which the predicted temperatures are expected to vary. The uncertainty analysis was preformed by coupling STAR-CCM+ with the software Dakota, which provides advanced parametric analyses, including quantification of margins and uncertainty with computational models. This work is expected to provide insight into SNF canister behavior.

Carpenter-Graffy, Dina E.↗

A Safe Response to Renewable Energy Hazards

The International Association of Fire Fighters (IAFF) and Underwriters Laboratories, LLC (UL) in conjunction with UL Solutions initiated a joint project in 2022 under an agreement with the United States Department of Energy-Office of Energy Efficiency and Renewable Energy (DOE-EERE). This project focused on two separate and important initiatives related to energy efficiency in residential buildings. Initiative 1: Fire Performance on Energy Efficient Exterior Walls. Initiative 2: Firefighting Tactics in Residential Properties with Building Energy Storage Systems (BESS). The project’s first initiative addresses concerns surrounding new technologies with enhanced, energy-efficient exterior walls installed on residential properties. The concerns of fire rapidly traveling vertically up the exterior of these walls were examined. This addressed a growing concern from the first responder community that many times, the fires on the exterior of residential buildings have already evolved into an attic fire by the time of arrival – making it problematic to address the fire scenario. The test plan for Initiative 1 incorporated a modified version of an American Society for Testing and Materials (ASTM) test method, ASTM E2707, Standard Test Method for Determining Fire Penetration of Exterior Wall Assemblies Using a Direct Flame Impingement Exposure, as the foundation of the research. The test method involved a wall structure intended to represent retrofit construction to evaluate how fire would spread vertically or laterally. The second aspect of the UL-IAFF Project focuses on the fire service response to Residential Battery Energy Storage System (RBESS) incidents. These simulation tests were constructed in the large-scale fire test facility at UL Solutions’ Northbrook, IL campus. A baseline test was conducted that involved a test structure with no batteries—shelving units populated with standardized commodities, representing a typical garage with cellulosic and plastic contents. Three additional tests have been conducted to generate data with the contribution of energy storage system (ESS) batteries to compare fire and explosion hazards against the baseline test. Through this work, fire service tactical considerations can be explored. From the data, the team can determine 1) the visual indicators of a residential fire that has involved an RBESS (or, potentially, other large batteries) and 2) the impact of fire service-initiated ventilation of the structure on the fire conditions and explosion risks.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Unsteady thermotechnical model of a closed flat plate solar collector–storage tank system

The main provisions of the developed numerical unsteady model of the flat plate solar collector–storage tank (SC–ST) system are given. The model takes into account all of the main parameters of the SC (receiver parameters, radiative properties of the transparent fence for solar radiation, and thermophysical properties of the thermal insulation of the bottom) and the ST (thermophysical parameters of thermal insulation). An algorithm and a program for calculating the thermal properties of a closed SC–ST system have been developed based on this model in the Delphi language. The results of the calculated estimates of the time variation of water heating temperatures in the ST and the efficiency of the closed SC–ST system as a function of the ST volume are given for the case where the water temperature at the SC inlet is equal to the mean water temperature in the ST. The model and the program also make it possible to determine the time variation of temperatures of SC elements and water in individual sections along the length of the SC as well as the thermal losses of the SC sections. The model makes it possible to estimate the effect of the thermal properties of SC elements and the water velocity on the thermal properties of the SC–ST system. The program can be modified for the case of the open SC–ST system, i.e., where the water temperature at the SC inlet does not depend on the water temperature in the ST.

14 SOLAR ENERGY↗