Search NASA⌕ Search

SEARCH · Search NASA

Results for “Surface sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

HRTEM study of track evolution in 120-MeV U irradiated Gd2Ti2O7

High resolution Scanning Transmission Electron Microscopy (HRTEM) experiments were performed on Gd2Ti2O7 pyrochlores irradiated with 120-MeV U ions. A judicious choice of irradiation energy, sample preparation (using Focused Ion Beam) and analytical technique (HRTEM) allowed us to visualize the complete evolution of tracks from the surface of samples down to depths exceeding the projected range of irradiating ions. Such features as variation of track diameters, changes in track directions and discontinuous segments of tracks were clearly documented at various depths. By using two different STEM imaging modes: High- and Low-Angle Annular Dark Field imaging (HAADF and LAADF), it was possible to observe the layered structure of tracks composed of an amorphous core surrounded by a strained crystalline envelope.

120↗

Measurement of surface microtopography

Acquisition of ground truth data for use in microwave interaction modeling requires measurement of surface roughness sampled at intervals comparable to a fraction of the microwave wavelength and extensive enough to adequately represent the statistics of a surface unit. Sub-centimetric measurement accuracy is thus required over large areas, and existing techniques are usually inadequate. A technique is discussed for acquiring the necessary photogrammetric data using twin film cameras mounted on a helicopter. In an attempt to eliminate tedious data reduction, an automated technique was applied to the helicopter photographs, and results were compared to those produced by conventional stereogrammetry. Derived root-mean-square (RMS) roughness for the same stereo-pair was 7.5 cm for the automated technique versus 6.5 cm for the manual method. The principal source of error is probably due to vegetation in the scene, which affects the automated technique but is ignored by a human operator.

Wall, S. D.↗

Phase II and III Solid Waste Management Unit Assessment and Confirmatory Sampling Report for Per- and Polyfluorinated Alkyl Substances, Potential Release Location 237, Kennedy Space Center, Florida

Per- and polyfluoroalkyl substances (PFAS) Phase II and III Solid Waste Management Unit (SWMU) Assessment (SA) and Confirmatory Sampling (CS) were conducted at the John F. Kennedy Space Center (KSC), Potential Release Location (PRL) 237, located in Merritt Island, Brevard County, Florida for the National Aeronautics and Space Administration (NASA) under Contract 80KSC019D0010/80KSC019F0289. A Phase I SA and CS Report was previously submitted that identified 33 locations of concern (LOCs) at KSC associated with the storage, use, or release of materials containing PFAS. The objectives of the Phase II and III SA and CS were to: - Complete site and source characterization of identified LOCs; - Identify areas of potential concern (AOPCs) where past or present activities may have resulted in a release of PFAS to the environment; - Qualitatively characterize migration potential of released PFAS to environmental media (primarily soil, groundwater, surface water, and sediment); and - Identify potential receptors for exposure to PFAS-impacted environmental media. Surface water samples were collected from LOCs/AOPCs and locations on the KSC periphery during PFAS CS Phases I, II and III. Including duplicate samples, 143 environmental samples were analyzed for 14 PFAS compounds and 104 environmental samples were analyzed for 18 PFAS compounds. Ten of the analytes on the 14 compound list were detected at least once in surface water at KSC, with a wide range in magnitude of detections. The State of Florida has surface water screening levels (SWSLs) for perfluorooctanoic acid (PFOA) and perfluorooctanesulfonic acid (PFOS) in surface water, both for human and ecological receptors. The human health screening levels are lower than the ecological ones and are used in this report. PFOA was not detected in surface water at concentrations exceeding the SWSL at any LOC or Area of Potential Concern (AOPC). PFOS was detected in surface water at concentrations exceeding the SWSL at 28 LOCs/AOPCs, plus 42 locations on the KSC periphery. The data suggest a wide distribution of PFAS, particularly PFOS, in surface water but the sources of surface water contamination are not yet adequately understood. Sediment samples were collected during Phases II and III but not Phase I. Including duplicate samples, 104 environmental samples were analyzed for 14 PFAS compounds and 10 environmental samples were analyzed for 18 PFAS compounds. Twelve compounds were detected in sediment at KSC, with a wide range in magnitude of detections. There are currently no screening levels or cleanup target levels (CTLs) for sediment. The need to delineate and further characterize PFAS in sediment will be evaluated for those sites that move forward into Site Assessment. Groundwater samples were collected via DPT from LOCs/AOPCs and locations on the KSC periphery during PFAS CS Phases I, II and III. Including duplicate samples, 812 environmental DPT groundwater samples were analyzed for 14 PFAS compounds and 247 environmental samples were analyzed for 18 PFAS compounds. Twelve of the 14 compounds were detected in groundwater at KSC, with a wide range in magnitude of detections. The State of Florida has provisional groundwater cleanup target levels (GCTLs) for PFOA, PFOS and the additive concentration of PFOA+PFOS. PFOA was detected in groundwater at concentrations exceeding its provisional GCTL at 16 LOCs/AOPCs, with no exceedances on the KSC periphery. PFOS was detected in groundwater at concentrations exceeding its provisional GCTL at 30 LOCs/AOPCs, plus two locations on the KSC periphery. PFOA+PFOS was detected in groundwater at concentrations exceeding the provisional GCTL at 31 LOCs/AOPCs, plus two locations on the KSC periphery. Soil samples were collected during Phases II and III but not Phase I. Including duplicate samples, 292 environmental samples were analyzed for 14 PFAS compounds and 80 environmental samples were analyzed for 18 PFAS compounds. Fourteen compounds were detected in soil at KSC, with a wide range in magnitude of detections. The State of Florida has provisional soil cleanup target levels (SCTLs) for PFOA and PFOS. There were no PFOA results above its provisional SCTL. There was one LOC with a result above the provisional SCTL for residential settings. Recommendations are presented for each LOC and AOPC.

PFAS↗

Remedial Investigation of Hanford Site Releases to the Columbia River - 13603

In south-central Washington State, the Columbia River flows through the U.S. Department of Energy Hanford Site. A primary objective of the Hanford Site cleanup mission is protection of the Columbia River, through remediation of contaminated soil and groundwater that resulted from its weapons production mission. Within the Columbia River system, surface water, sediment, and biota samples related to potential Hanford Site hazardous substance releases have been collected since the start of Hanford operations. The impacts from release of Hanford Site radioactive substances to the Columbia River in areas upstream, within, and downstream of the Hanford Site boundary have been previously investigated as mandated by the U.S. Department of Energy requirements under the Atomic Energy Act. The Remedial Investigation Work Plan for Hanford Site Releases to the Columbia River [1] was issued in 2008 to initiate assessment of the impacts under the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 [2]. The work plan established a phased approach to characterize contaminants, assess current risks, and determine whether or not there is a need for any cleanup actions. Field investigation activities over a 120-mile stretch of the Columbia River began in October 2008 and were completed in 2010. Sampled media included surface water, pore water, surface and core sediment, island soil, and fish (carp, walleye, whitefish, sucker, small-mouth bass, and sturgeon). Information and sample results from the field investigation were used to characterize current conditions within the Columbia River and assess whether current conditions posed a risk to ecological or human receptors that would merit additional study or response actions under CERCLA. The human health and ecological risk assessments are documented in reports that were published in 2012 [3, 4]. Conclusions from the risk assessment reports are being summarized and integrated with remedial investigation/feasibility study (RI/FS) reports developed for upland areas, riparian areas, and groundwater in the Hanford Site River Corridor. The RI/FS reports will evaluate the impacts to soil, groundwater, and river sediments and lead to proposed cleanup actions and records of decision to address releases from the Hanford Site reactor operations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Plutonium Migration during the Leaching of Cemented Radioactive Waste Sludges

One of the most challenging components of the UK nuclear legacy is Magnox sludge, arising from the corrosion of Mg alloy-clad irradiated metallic U fuel that has been stored in high pH ponds. The sludges mainly comprise Mg hydroxide and carbonate phases, contaminated with fission products and actinides, including Pu. Cementation and deep geological disposal is one option for the long-term management of this material, but there is a need to understand how Pu may be leached from the waste, if it is exposed to groundwater. Here, we show that cemented Mg(OH) 2 powder prepared with Pu(IV) aq is altered on contact with water to produce a visibly altered ‘leached zone’, which penetrates several hundred microns into the sample. In turn, this zone shows slow leaching of Pu, with long-term leaching rates between 1.8–4.4 × 10 -5 % of total Pu per day. Synchrotron micro-focus X-ray fluorescence mapping identified decreased Pu concentration within the ‘leached zone’. A comparison of micro-focus X-ray absorption spectroscopy (µ-XAS) spectra collected across both leached and unleached samples showed little variation, and indicated that Pu was present in a similar oxidation state and coordination environment. Fitting of the XANES spectra between single oxidation state standards and EXAFS modeling showed that Pu was present as a mixture of Pu(IV) and Pu(V). The change in Pu oxidation from the stock solution suggests that partial Pu oxidation occurred during sample ageing. Similarity in the XAS spectra from all samples, with different local chemistries, indicated that the Pu oxidation state was not perturbed by macro-scale variations in cement chemistry, surface oxidation, sample aging, or the leaching treatment. These experiments have demonstrated the potential for leaching of Pu from cementitious waste forms, and its underlying significance requires further investigation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Remote System for Characterizing, Monitoring and Inspecting the Inside of Contaminated Nuclear Stacks

The Stack Characterization System (SCS) is a collaborative project with the Robotics and Energetic Systems Group (RESG) at Oak Ridge National Laboratory (ORNL) and the Applied Research Center (ARC) at Florida International University (FIU). The SCS is a robotic system that will be deployed into off-gas stacks located around the central campus at ORNL. The system will consists of surveying equipment capable of taking surface contamination samples, radiation readings, core samples and transmit live video to its operators. Trade studies were conducted on varying concrete materials to determine the best way of retrieving loose contamination from the surface. The studies were performed at the ARC facility by DOE Fellows, where traditional cloth wipes were compared to adhesive material. The adhesive material was tested on the RESG s smear sampler to record how much loose surface material could be retrieved. The DOE Fellows completed a summer internship during which conceptual designs were created for a deployable radiation detector and core drill capable of retrieving multiple core samples.

Vargas, Mario↗

GAMA-LLNL Alpine Basin Special Study: Scope of Work

For this task LLNL will examine the vulnerability of drinking water supplies in foothills and higher elevation areas to climate change impacts on recharge. Recharge locations and vulnerability will be determined through examination of groundwater ages and noble gas recharge temperatures in high elevation basins. LLNL will determine whether short residence times are common in one or more subalpine basin. LLNL will measure groundwater ages, recharge temperatures, hydrogen and oxygen isotopes, major anions and carbon isotope compositions on up to 60 samples from monitoring wells and production wells in these basins. In addition, a small number of carbon isotope analyses will be performed on surface water samples. The deliverable for this task will be a technical report that provides the measured data and an interpretation of the data from one or more subalpine basins. Data interpretation will: (1) Consider climate change impacts to recharge and its impact on water quality; (2) Determine primary recharge locations and their vulnerability to climate change; and (3) Delineate the most vulnerable areas and describe the likely impacts to recharge.

54 ENVIRONMENTAL SCIENCES↗

Depth profiling and standardization from the back side of a sample for accurate analyses: Emphasis on quantifying low‐fluence, shallow implants in diamond‐like carbon

Rationale Back‐side thinning of wafers is used to eliminate issues with transient sputtering when analyzing near‐surface element distributions. Precise and accurate calibrated implants are created by including a standard reference material during the implantation. Combining these methods allows accurate analysis of low‐fluence, shallow features even if matrix effects are a concern. Methods Implanted Na (<2.0 × 10 11 ions/cm 2 , peaking <50 nm) in diamond‐like carbon (DLC) film on silicon (solar wind returned by NASA's Genesis mission) was prepared for measurement as follows. Implanted surfaces of samples were epoxied to wafers and back‐side‐thinned using physical or chemical methods. Thinned samples were then implanted with reference ions for accurate quantification of the solar wind implant. Analyses used a CAMECA IMS 7f‐GEO SIMS in depth‐profiling mode. Results Back‐side‐implanted reference ions reduced the need to change sample mounts or stage position and could be spatially separated from the solar wind implant even when measuring monoisotopic ions. Matrix effects in DLC were mitigated and the need to find an identical piece of DLC for a reference implant was eliminated. Accuracy was only limited by the back‐side technique itself. Conclusions Combining back‐side depth profiling with back‐side‐implanted internal standards aides quantification of shallow mono‐ and polyisotopic implants. This technique helps mitigate matrix effects and keeps measurement conditions consistent. Depth profile acquisition times are longer, but if sample matrices are homogeneous, procedural changes can decrease measurement times.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Organic constituents in eolian dust and surface sediments from northwest Africa

Samples of eolian dust and comparably sized desert surface sediment samples collected over widely scattered regions of northwest Africa were analyzed for carbon, nitrogen, and hydrogen content and total carbohydrate. Infrared analysis and gas chromatographic analysis were also performed on organic components extracted from several of these samples. Although the total carbon content of the eolian dust samples varies from 2.8 to 7.0% by weight, the organic carbon component is relatively uniform at 2.9 + or - 0.5%. By comparison, the average organic carbon content of the African surface sediments is 0.7 + or - 0.5%. Total carbohydrate content averages 0.128% for the dust and 0.022% for the desert sediments. It is shown that these desert regions are not presently the principal sources of eolian material transported over the North Atlantic Ocean.

Lepple, F. K.↗

RF Surface Impedance Measurement of Polycrystalline and Large Grain Nb Disk Sample at 7.5 GHz

A Surface Impedance Characterization (SIC) system has been proposed at the 2005 SRF workshop and recently updated as detailed at the 2009 PAC conference. Currently the SIC system can measure samples in a temperature range from 2K to 20K exposed to an RF magnetic flux density of less than 3mT. We report on new results of a BCP etched large grain Nb sample measured with this system as compared with previous results of a BCP etched polycrystalline Nb sample. The design of an upgraded SIC system for use at higher magnetic flux densities is on the way to more efficiently investigate correlations between local material characteristics and associated SRF properties, both for preparation studies of bulk niobium and also new thin film SRF developments.

36 MATERIALS SCIENCE↗

Method development for determining the hydraulic conductivity of fractured porous media

Plausible, but unvalidated, theoretical model constructs for unsaturated hydraulic conductivity of fractured porous media are currently used in Performance Assessment (PA) modeling for cracked saltstone and concrete (Flach 2011). The Nuclear Regulatory Commission (NRC) has expressed concern about the lack of model support for these assumed Moisture Characteristic Curves (MCC) data, as noted in Requests for Additional Information (RAIs) PA-8 and SP-4 (Savannah River Remediation, LLC, 2011). The objective of this task was to advance PA model support by developing an experimental method for determining the hydraulic conductivity of fractured cementitious materials under unsaturated conditions, and to demonstrate the technique on fractured saltstone samples. The task was requested through Task Technical Request (TTR) HLW-SSF-TTR-2012-0016 and conducted in accordance with Task Technical & Quality Assurance Plan (TTQAP) SRNL-TR-2012-00090. Preliminary method development previously conducted by Kohn et al. (2012) identified transient outflow extraction as the most promising method for characterizing the unsaturated properties of fractured porous media. While the research conducted by Kohn et al. (2012) focused on fractured media analogs such as stacked glass slides, the current task focused directly on fractured saltstone. For this task, four sample types with differing fracture geometries were considered: 1) intact saltstone, 2) intact saltstone with a single saw cut, smooth surface fracture, 3) micro-fractured saltstone (induced by oven drying), and 4) micro-fractured saltstone with a single, fully-penetrating, rough-surface fracture. Each sample type was tested initially for saturated hydraulic conductivity following method ASTM D 5084 using a flexible wall permeameter. Samples were subsequently tested using the transient outflow extraction method to determine cumulative outflow as a function of time and applied pressure. Of the four sample types tested, two yielded datasets suitable for analysis (sample types 3 and 4). The intact saltstone sample (sample type 1) did not yield any measureable outflow over the pressure range of the outflow test (0-1000 cm H 2 O). This was expected because the estimated air entry pressure for intact saltstone is on the order of 100,000 cm H 2 O (Dixon et al., 2009). The intact saltstone sample with a single saw cut smooth surface fracture (sample type 2) did not produce useable data because the fracture completely drained at less than 10 cm H 2 O applied pressure. The cumulative outflow data from sample types 3 and 4 were analyzed using an inverse solution of the Richard’s equation for water flow in variably saturated porous media. This technique was implemented using the computer code Hydrus-1D (Šimunek et al., 2008) and the resulting output included the van Genuchten-Mualem water retention and relative permeability parameters and predicted saturated hydraulic conductivity (Van Genuchten, 1980; Van Genuchten et al., 1991). Estimations of relative permeability and saturated conductivity are possible because the transient response of the sample to pressure changes is recorded during the multi-step outflow extraction test. Characteristic curves were developed for sample types 3 and 4 based on the results of the transient outflow method and compared to that of intact saltstone previously reported by Dixon et al. (2009). The overall results of this study indicate that the outflow extraction method is suitable for measuring the hydraulic properties of micro-fractured porous media. The resulting cumulative outflow data can be analyzed using the computer code Hydrus-1D to generate the van Genuchten curve fitting parameters that adequately describe fracture drainage. The resulting characteristic curves are consistent with blended characteristic curves that combine the behaviors of low pressure drainage associated with fracture flow with high pressure drainage from the bulk saltstone matrix.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Strategy for Ranking the Science Value of the Surface of Asteroid 101955 Bennu for Sample Site Selection for Osiris-REx

OSRIS-REx is NASA's New Frontiers 3 sample return mission that will return at least 60 g of pristine surface material from near-Earth asteroid 101955 Bennu in September 2023. The scientific value of the sample increases enormously with the amount of knowledge captured about the geological context from which the sample is collected. The OSIRIS-REx spacecraft is highly maneuverable and capable of investigating the surface of Bennu at scales down to the sub-cm. The OSIRIS-REx instruments will characterize the overall surface geology including spectral properties, microtexture, and geochemistry of the regolith at the sampling site in exquisite detail for up to 505 days after encountering Bennu in August 2018. The mission requires at the very minimum one acceptable location on the asteroid where a touch-and-go (TAG) sample collection maneuver can be successfully per-formed. Sample site selection requires that the follow-ing maps be produced: Safety, Deliverability, Sampleability, and finally Science Value. If areas on the surface are designated as safe, navigation can fly to them, and they have ingestible regolith, then the scientific value of one site over another will guide site selection.

Nakamura-Messenger, K.↗

Constraining the Surface Exposure Age of Asteroid Bennu Using Cosmogenic Radionuclides in an OSIRIS-REx Aggregate Sample and Individual Particles

Observations by NASA’s OSIRIS-REx spacecraft of asteroid Bennu revealed evidence that this small rubble-pile asteroid experiences several active surface processes that likely control its recent surface exposure history. In October 2020, the spacecraft collected a surface sample from a relatively young ~20 m diameter crater (Hokioi) on asteroid Bennu, and the sample was successfully delivered to Earth on September 24, 2023. Based on the population of craters >50 m diameter, Bennu’s surface is 0.1–1 Ga old, but the old surface is affected by recent processes including smaller meteoroid impacts, mass movement, and particle ejections. The sampling location within Hokioi crater was selected based on its relatively flat surface devoid of large boulders, but the crater floor is also believed to be one of the youngest surfaces on asteroid Bennu, with an age of <100 kyr. As the crater is ~2 m deep, the samples that were collected by OSIRIS-REx may have been relatively shielded from cosmic rays during most of its recent history. This scenario is different from the samples that were collected by Hayabusa2 from asteroid Ryugu, where cosmogenic noble gas and radionuclides indicate cosmic-ray exposure (CRE) ages of ~5 Myr near the surface. Our goal is to understand the recent exposure history of surface samples of asteroid Bennu utilizing radionuclides ( 10 Be, 26 Al, 36 Cl, 41 Ca) produced by both galactic (GCR) and solar (SCR) cosmic rays. With half- lives ranging from 0.1 to 1.36 million years (Myr), the concentrations of these cosmogenic nuclides provide information on the duration and exposure conditions (irradiation depth) of these samples on a timescale of a few Myr. This work will test one of the OSIRIS-REx mission’s driving hypotheses about asteroid Bennu’s recent evolution: that Hokioi crater is part of a population of small (25 m) spectrally red craters on Bennu that are less than 0.1 Myr old.

K. C. Welten↗

An Assessment of Molten Metal Detachment Hazards During Electron Beam Welding in Space

The safety issue has been raised with regards to potential molten metal detachments from the weld pool and cold filler wire during electron beam welding in space. This investigation was undertaken to evaluate if molten metal could detach and come in contact with astronauts and burn through the fabric of the astronauts' Extravehicular Mobility Unit (EMU) during electron beam welding in space. Molten metal detachments from either the weld/cut substrate or weld wire could present harm to a astronaut if the detachment was to burn through the fabric of the EMU. Theoretical models were developed to predict the possibility and size of the molten metal detachment hazards during the electron beam welding exercises at Low Earth Orbit (LEO). The primary molten metal detachment concerns were those cases of molten metal separation from the metal surface due to metal cutting, weld pool splashing, entrainment and release of molten metal due to filler wire snap-out from the weld puddle, and molten metal accumulation and release from the end of the weld wire. Some possible ways of obtaining molten metal drop detachments would include an impulse force, or bump, to the weld sample, cut surface, or filler wire. Theoretical models were developed for these detachment concerns from principles of impact and kinetic energies, surface tension, drop geometry, surface energies, and particle dynamics. The surface tension represents the force opposing the liquid metal drop from detaching whereas the weight of the liquid metal droplet represents a force that is tending to detach the molten metal drop. Theoretical calculations have indicated that only a small amount of energy is required to detach a liquid metal drop; however, much of the energy of an impact is absorbed in the sample or weld plate before it reaches the metal drop on the cut edge or surface. The tendency for detachment is directly proportional to the weld pool radius and metal density and inversely proportional to the surface tension of the liquid metal. For a detachment the initial kinetic energy of the weld pool with respect to the plate has to exceed the energy to form the extra surface required for the detachment of the pool. The difficulty is in transferring the energy from the point of impact through the plate and sample to the cut edge. It is likely that not all of the kinetic energy is available for detaching the pool; some may be sequestered in weld pool oscillations. The coefficient of restitution for the collision will be lower than one if irreversible deformation, for example plastic flow deformation, takes place during the collision. Thus determining the amount of energy from an impact that actually reaches the molten metal droplet is critical. Various molten metal detachment scenarios were tested experimentally in an enclosed vacuum chamber using the Ukrainian Universal Hand Tool, an electron beam welder designed for space welding. The experimental testing was performed in a 4 ft. X 4 ft. vacuum chamber at Marshall Space Flight Center, evacuated to vacuum levels of at least 50 microTorr, and also some welding garment material was utilized to observe the effect of the molten metal detachments on the material. A "carillon" apparatus consisting of four pendulum hammer strikers, each weighing approximately 3.65 lbs, raised to predetermined specific heights was used to apply an impact force to the weld sample/plate during electron beam welding and cutting exercises. The strikers were released by switching on an electric motor to rotate a pin holding wires retaining the strikers at desired heights. The specimens were suspended so as to be free to respond to the blows with a sudden velocity increment. The specimens were mounted on a hinged plate for minimizing effective mass with the option to fasten it down so as to raise its effective mass closer to that anticipated for an actual space welding scenario. Measurements were made of the impact energy and the horizontal fling distances of the detached metal drops. It was not particularly easy to generate the detachments for this experiment. This document presents the details of the theoretical modeling effort and a summary of the experimental effort to measure molten metal drop detachments from terrestrial electron beam welding in the enclosed vacuum chamber. The results of the experimental effort have shown that molten metal detachments can occur from the sample/weld plate only if a sufficiently large impact force is applied to the weld plate. A "weld pool detachment parameter" was determined to indicate whether detachment would occur. Detachment can be either full or partial (dripping), Partial detachment means that the weld pool detached from one side of the liquid-solid boundary so as to leave a hole at the puddle site but remained attached over part of the liquid-solid boundary and dripped down the plate with no fully detached material detected. Full detachment, however, does not necessarily mean that the whole pool fully detached; in some cases only a smaller portion of the pool detached, the remainder dripping down the plate. The weld pool detachment parameter according to theory and according to the empirical data allows a determination of whether full detachments might occur. Theoretical calculations indicated titanium alloy would be the most difficult from which to detach molten metal droplets followed by stainless steel and then by aluminum. The experimental results were for the most part consistent with the theoretical analysis and predictions. The above theory is applicable to other situations as desired for assessing the potential for molten metal detachments.

Fragomeni, James M.↗

Doping effect of nano-Ho{sub 2}O{sub 3} and naphthalene in MgB{sub 2} superconductor prepared by powder-in-sealed-tube method

The effect on crystal structure, critical temperature (T{sub C}), and critical current density (J{sub C}) of bulk MgB{sub 2} doped with nano-Ho{sub 2}O{sub 3} and naphthalene was studied. Among all the samples studied, the sample doped with 2.5 wt. % nano-Ho{sub 2}O{sub 3} have shown the best field dependent critical current density [J{sub C}(H)], i.e., 0.77 × 10{sup 5 }A/cm{sup 2} at 2 T and 10 K. While naphthalene doped MgB{sub 2} sample has shown the least J{sub C}(H) characteristics. The improved J{sub C}(H) characteristics in the nano-Ho{sub 2}O{sub 3} doped MgB{sub 2} samples are attributed to improved flux pinning properties due to the formation of HoB{sub 4} and in naphthalene doped MgB{sub 2} samples. The slight lower T{sub C} value (37.01 K) in naphthalene doped samples is attributed to the occurrence of lattice defect by the substitution of carbon at boron site of MgB{sub 2} superconductor. Lower ΔT{sub C} value implies the lesser anisotropy in all the synthesized samples. The flux pinning force density (F{sub P}/F{sub Pmax}) curves are theoretically analyzed using Dew-Hughes model. The result revealed that point pinning is the dominant pinning mechanism for nano-Ho{sub 2}O{sub 3} doped MgB{sub 2} samples, while, surface and grain boundary pinning become dominant with increasing naphthalene addition in nano-Ho{sub 2}O{sub 3} doped MgB{sub 2} samples.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Containerless processing of undercooled melts

Containerless drop tube processing allows for significant levels of liquid undercooling through control of parameters such as sample size, surface coating and cooling rate. A laboratory scale (3 m) drop tube has been developed which allows the undercooling and solidification behavior of powder samples to be evaluated under low gravity free-fall conditions. The level of undercooling obtained in an InSb-Sb eutectic alloy has been evaluated by comparing the eutectic spacing in drop tube samples with a spacing/undercooling relationship established using thermal analysis techniques. Undercoolings of 0.17 and 0.23 T(e) were produced by processing under vacuum and He gas conditions respectively. Alternatively, the formation of an amorphous phase in a Ni-Nb eutectic alloy indicates that undercooling levels of approximately 500 C were obtained by drop tube processing. The influence of droplet size and gas environment on undercooling behavior in the Ni-Nb eutectic was evaluated through their effect on the amorphous/crystalline phase ratio. To supplement the structural analysis, heat flow modeling has been developed to describe the undercooling history during drop tube processing, and the model has been tested experimentally.

Shong, D. S.↗

Development of Broadband Microwave Absorber and Measurement of Its Magnetic and Microwave Properties

Toroid shape Co-doped barium hexaferrites of composition (BaFe{sub 11}CoO{sub 19}) are prepared by standard sintering technology as a sample. In this work, XRD is used to identify the structure of synthesized sample. Vibrating sample magnetometer is used to obtain magnetic hysteresis loop of sample. Scanning electron microscope is used for surface morphology of sample. The complex permeability and permittivity are measured with commercial automation measurement set up in the 2–18 GHz frequency range. As a result of measurement, the calculation of reflection loss of the synthesized samples has been carried out. Investigation of microwave absorption properties revealed that the maximum reflection loss of Co-doped barium hexaferrite sample is around −20 dB and almost flat in the measurement frequency band. From these results, it was concluded that Co-doped barium hexaferrites of composition had a good potential as microwave absorber in the broadband frequency range.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Subsoil Potassium in Central Iowa Soils: Status and Future Challenges

A reevaluation of plant-available K within central Iowa soils is needed, especially if crop residues are harvested for animal feed or cellulosic feedstock. This study evaluated plant-available K concentrations to depths of 120 cm (n = 2433) within soil profiles at 10 experimental sites. Data from 0- to 5-, 5- to 15-, 0- to 15-, 15- to 30-, 30- to 60-, 60- to 90-, and 90- to 120-cm depths were compiled and evaluated. Based on over 400 samples collected from each depth increment below 15 cm, a reference value of 100 mg kg –1 appears common for central Iowa subsoils. Sixty-four percent of all samples had soil-test K levels below the 120 mg kg –1 threshold for very low nutrient status for crop production in Iowa. Only 28% of surface soil samples (<15-cm depth) were considered to have at least optimum nutrient status with concentrations greater than 160 mg kg –1 . As K is not an environmentally sensitive nutrient, its management in central Iowa soils has generally been neglected in recent years, particularly when compared with N and P management initiatives. Building awareness of soil K profile concentrations, rather than focusing only on surface concentrations, will be necessary to meet nutrient requirements for 21st century agricultural production.

54 ENVIRONMENTAL SCIENCES↗