Search NASA⌕ Search

SEARCH · Search NASA

Results for “Transient testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

One Dimensional Analysis Model of a Condensing Spray Chamber Including Rocket Exhaust Using SINDA/FLUINT and CEA

Modeling droplet condensation via CFD codes can be very tedious, time consuming, and inaccurate. CFD codes may be tedious and time consuming in terms of using Lagrangian particle tracking approaches or particle sizing bins. Also since many codes ignore conduction through the droplet and or the degradating effect of heat and mass transfer if noncondensible species are present, the solutions may be inaccurate. The modeling of a condensing spray chamber where the significant size of the water droplets and the time and distance these droplets take to fall, can make the effect of droplet conduction a physical factor that needs to be considered in the model. Furthermore the presence of even a relatively small amount of noncondensible has been shown to reduce the amount of condensation. It is desirable then to create a modeling tool that addresses these issues. The path taken to create such a tool is illustrated. The application of this tool and subsequent results are based on the spray chamber in the Spacecraft Propulsion Research Facility (B2) located at NASA's Plum Brook Station that tested an RL-10 engine. The platform upon which the condensation physics is modeled is SINDAFLUINT. The use of SINDAFLUINT enables the ability to model various aspects of the entire testing facility, including the rocket exhaust duct flow and heat transfer to the exhaust duct wall. The ejector pumping system of the spray chamber is also easily implemented via SINDAFLUINT. The goal is to create a transient one dimensional flow and heat transfer model beginning at the rocket, continuing through the condensing spray chamber, and finally ending with the ejector pumping system. However the model of the condensing spray chamber may be run independently of the rocket and ejector systems detail, with only appropriate mass flow boundary conditions placed at the entrance and exit of the condensing spray chamber model. The model of the condensing spray chamber takes into account droplet conduction as well as the degrading effect of mass and heat transfer due to the presence of noncondensibles. The one dimension model of the condensing spray chamber makes no presupposition on the pressure profile within the chamber, allowing the implemented droplet physics of heat and mass transfer coupled to the SINDAFLUINT solver to determine a transient pressure profile of the condensing spray chamber. Model results compare well to the RL-10 engine pressure test data.

Chemical Equilibrium↗

One Dimensional Analysis Model of a Condensing Spray Chamber Including Rocket Exhaust Using SINDA/FLUINT and CEA

Modeling droplet condensation via CFD codes can be very tedious, time consuming, and inaccurate. CFD codes may be tedious and time consuming in terms of using Lagrangian particle tracking approaches or particle sizing bins. Also since many codes ignore conduction through the droplet and or the degradating effect of heat and mass transfer if noncondensible species are present, the solutions may be inaccurate. The modeling of a condensing spray chamber where the significant size of the water droplets and the time and distance these droplets take to fall, can make the effect of droplet conduction a physical factor that needs to be considered in the model. Furthermore the presence of even a relatively small amount of noncondensible has been shown to reduce the amount of condensation [Ref 1]. It is desirable then to create a modeling tool that addresses these issues. The path taken to create such a tool is illustrated. The application of this tool and subsequent results are based on the spray chamber in the Spacecraft Propulsion Research Facility (B2) located at NASA's Plum Brook Station that tested an RL-10 engine. The platform upon which the condensation physics is modeled is SINDAFLUINT. The use of SINDAFLUINT enables the ability to model various aspects of the entire testing facility, including the rocket exhaust duct flow and heat transfer to the exhaust duct wall. The ejector pumping system of the spray chamber is also easily implemented via SINDAFLUINT. The goal is to create a transient one dimensional flow and heat transfer model beginning at the rocket, continuing through the condensing spray chamber, and finally ending with the ejector pumping system. However the model of the condensing spray chamber may be run independently of the rocket and ejector systems detail, with only appropriate mass flow boundary conditions placed at the entrance and exit of the condensing spray chamber model. The model of the condensing spray chamber takes into account droplet conduction as well as the degrading effect of mass and heat transfer due to the presence of noncondensibles. The one dimension model of the condensing spray chamber makes no presupposition on the pressure profile within the chamber, allowing the implemented droplet physics of heat and mass transfer coupled to the SINDAFLUINT solver to determine a transient pressure profile of the condensing spray chamber. Model results compare well to the RL-10 engine pressure test data.

Condensing Spray Model↗

US Contributions to the Athena Wide Field Imager

The world’s premier X-ray astronomical observatories, Chandra and XMM-Newton, have been operating for about 20 years. The next flagship X-ray observatory launched will be ESA’s Athena mission. We discuss planned US contributions to the Athena Wide Field Imager instrument, which encompass transient source detection, background characterization and reduction, and detector electronics design and testing, in addition to scientific contributions.

David N. Burrows↗

Characterizing Electrical Arc Behavior in Ion Engines

Test results using an engineering model Advanced NEXT thruster are presented to identify different arc types utilizing ground test hardware. Three distinct arc types were observed: grid-to-grid arcs, high voltage-to-chassis arcs, and a combination of both. The frequency of high voltage-to-chassis arcs ranged from 4-30%, depending on operating conditions and hardware configuration. Higher beam currents were typically associated with more frequent high voltage-to-chassis arcs. During these arcs, the measured chassis current levels ranged from 20-70 A, however a significant portion of the output beam current returned to the beam supply via the neutralizer cathode plasma, which may be a ground test facility effect. The paper also discusses conducted susceptibility tests that can be performed at the spacecraft level to address the transients associated with arcing events.

electric propulsion↗

Evaluating Protection System Performance for a Real-World Weak Grid Area With High Inverter-Based Resources: Preprint

This paper evaluates an existing protection scheme implemented in a real-world weak grid area with a high penetration of inverter-based resources (IBRs). The study aims to assess the reliability and adequacy of protection schemes originally designed for traditional synchronous machine systems and determine whether they can continue to operate reliably in systems with high levels of IBRs. Hardware relays are tested using a controller-hardware-in-the-loop setup. PSCAD electromagnetic transient simulation with an IBR original equipment manufacturer black-box model is used to perform fault studies and generate COMTRADE data, which are replayed by a real-time digital simulator (RTDS) to feed input to the hardware relays. Three scenarios are analyzed: normal operation, an N-1 contingency, and an IBR-only scenario. The evaluation results reveal the following: 1) the protection scheme remains reliable under normal conditions and N-1 contingencies and 2) in IBR-only scenarios, differential protection (87L) continues to operate reliably, whereas local protection elements, such as distance and directional elements, fail because of the lack of regulated negative sequence current contributed by IBRs. These findings provide utilities with valuable insights for improving their protection systems in high-IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Large-Scale Hardware Experiment Demonstration of Operating High Inverter-Based Resource Power Systems With Grid-Forming Inverters

This paper presents experimental hardware results from a microgrid system as the penetration level of grid-forming (GFM) inverters increases. The experiment aims to showcase the advantages of GFM inverters in enhancing system stability and to investigate the operational challenges in systems relying entirely on inverter-based resources (IBRs). Five test scenarios are devised to progressively increase GFM inverter penetration levels: 0% (S1), 19% (S2), 37% (S3), 68% (S4), and 100% (S5). To ensure consistency, identical loading conditions and dynamic events are applied across all scenarios. The conducted tests include load step changes, output variation of grid-following (GFL) inverters during islanded mode, transition operations (such as synchronization to the grid and islanding), and rateof- change-of-frequency (ROCOF) and voltage jump tests during grid-connected mode. Key findings from the tests are summarized as follows: (1) Scenario S1 proved most challenging for load steps, and GFL variations because of insufficient GFM capacity, leaving the diesel generator unable to handle transient ridethrough; (2) Scenario S5 was the most difficult for transition operations, because the lack of a diesel generator to maintain stiff bus voltage resulted in unexpected reactive power flows during synchronization, causing the point of common coupling (PCC) breaker to trip; (3) Scenarios S4 and S5 were particularly challenging for ROCOF tests because of minimal system inertia, leading to large transients that triggered breaker trips; and (4) Scenario S4 exhibited the strongest voltage recovery capability because of the presence of the diesel generator and a higher number of GFM inverters, both of which possess the highest capacity for reactive power injection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Test-Based Modeling of Photovoltaic Inverter Impact on Distribution Systems

Distributed PV has important effects on overcurrent, overvoltage and islanding protection. These effects are more difficult to analyze because the faulted behavior of PV inverters is less well understood than for rotating machines. Full transient models of the inverter can be accurate, but that approach requires inverter design details and simulation software that doesn’t easily interoperate with utility protection system software. Further, anomalous model behaviors often emerge at different grid conditions, and these are difficult to fix in a proprietary model. Testing provides another approach to characterize inverters, validate models or answer questions of application. This earlier work found major impacts from the inverter design, firmware, operating point and balance-of-system components. Our objective is to characterize PV inverters from black-box testing, leading to standard test reports that could provide parameter sets for widely-implemented models in software tools. The tool vendors can then develop standard inverter models, as they did for rotating machines and exciters. Besides fully detailed transient models, inverters can be represented with steady-state current sources, dynamically controlled current sources or non-linear frequency-dependent black boxes. Type-test data could support the last three kinds of model. Short circuit and sag tests would encompass the basic fault types, reporting the maximum transient and rms currents over all power levels and points-on-wave within four time ranges : 1) 0 to 1 cycles, for close and latch consideration 2) 1 to 4 cycles, for equipment withstand 3) 4 to 30 cycles, for interrupt ratings 4) 30 cycles and beyond, for backup protection analysis Open circuit tests would vary output power and power factor, and report the maximum rms voltage from 1 to 10 cycles after the event. Without models, the type-test data could also provide upper limits on the expected overvoltages and overcurrents.

Wieserman, Laura M.↗

Analysis of AP1000 Small-Break Loss-of-Coolant Accident Using Reactor Transient Simulator

The Westinghouse Electric Company’s Advanced Passive Reactor (AP1000) is characterized by the incorporation of passive safety systems (PSSs) designed to ensure core cooling during transient events. The assessment of PSSs requires evaluation of their performance through a combination of experiments and simulations employing various thermal-hydraulic codes. In addition, detailed evaluation of PSSs for a specific reactor system transient analysis such as loss-of-coolant-accident analysis supports understanding representative integral effects test facility development and the further evolution model development and assessment process. Developing a reactor system code is a complex and time-consuming process that requires significant engineering expertise and effort. It can take several months to even years to complete in the early stages of reactor system design and analysis. However, this process can be expedited through the use of transient simulator models for similar reactor systems, which can be used for lesson learning and training purposes. This study uses the Personal Computer Transient Analyzer (PCTRAN) code. The main advantage of PCTRAN is its ease of use and ability to run faster than real time. This study presents the results obtained for a small-break loss-of-coolant accident (SBLOCA) for two breaks using the full version (licensed) of PCTRAN. The purpose of this investigation is to evaluate the overall system behavior during the postulated SBLOCA event as well as assess the capability of the PCTRAN code to reproduce the system response during transient events. The obtained results were compared with the Westinghouse NOTRUMP system code. The PCTRAN code proved to be reliable in predicting the qualitative behavior of the system in both transient cases. As for the system response, it was found that it is contingent on the activation time of the PSSs. The differences in reactor coolant system pressure between the two codes were attributed to the critical flow model and simplification of mass and energy balance. Despite PCTRAN’s limitations, it can still provide a reasonable prediction of various reactor parameters such as pressure, mass flow rate, and void fraction during a SBLOCA scenario. It is worth noting that PCTRAN currently employs a bulk approach similar to that of the Modular Accident Analysis Program (MAAP) and MELCOR codes. However, the upcoming version of PCTRAN will include an artificial intelligence–based detection and accident prevention system, as well as different models for different reactor components. Consequently, PCTRAN has the potential to be upgraded to match the system thermal-hydraulic codes of the U.S. Nuclear Regulatory Commission and become more widely used in cybersecurity to safeguard nuclear power plants from cyberattacks.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Updates and Correlation of EMU System-Level Model (SINDA EMU)

During United States Extravehicular Activity 80 (US EVA 80), water was observed in the helmet of an Extravehicular Mobility Unit (EMU) during cabin repressurization. One of the primary methods of determining the likely cause of this failure was through a comparison of EVA 80 to other historical EVAs using an analytical approach. The Systems Improved Numerical Differential Analysis EMU model (SINDA EMU) is a system-level model of the EMU that was used in this investigation. SINDA EMU was initially developed and correlated to test data in the 1980s. Since its conception, SINDA EMU has been continually adjusted based on new test data and changes to the EMU design. To support the water in the helmet investigation, SINDA EMU needed to be further updated and recorrelated to ensure accurate results. These changes included changing the primary carbon dioxide (CO2) removal technology, implementing logic to allow for re-evaporation of sweat runoff from the liquid cooling and ventilation garment (LCVG), and improving the transient modeling capabilities. To validate the implementation of these adjustments, SINDA EMU was correlated to test data from the 1990s and human-in-the-loop (HITL) testing from 2014. These updates and correlation efforts proved that SINDA EMU is an effective tool for investigating the EVA 80 water in the helmet failure event.

Noah Lial Andersen↗

SCANAIR-BISON BENCHMARK ON CIP0-1 RIA TEST

In the frame of their research programs on fuel safety, the French “Institut de Radioprotection et de Sûreté Nucléaire” (IRSN) and the Idaho National Laboratory (INL) have developed respectively SCANAIR and BISON codes to describe the thermo-mechanical behavior of irradiated fuel rods during Reactivity Initiated Accidents (RIA) in LWR. A RIA, characterized by a very rapid increase of reactivity and power in some rods of the reactor, can be schematically represented in two main phases. First, the energy deposition leads to a rapid rise of the fuel temperature which induces thermal swelling of the fuel pellets. During this phase, the Pellet Clad Mechanical Interaction (PCMI) leads to clad deformation and potentially to failure depending on fuel enthalpy increase and on the level of clad embrittlement. After the PCMI phase, the increase of clad temperature can lead to the boiling crisis of the water surrounding the rod. During the film boiling phase, the clad to coolant heat transfer becomes very low and the clad can reach high temperature (>700°C). Depending on the internal gas pressure, the ductile clad can undergo large deformation and possible failure. The RIA codes have to predict properly these two phases of the transient in order to be used, in particular, to assess current fuel safety criteria but also to be able to predict the behavior of upcoming fuel (such as accident tolerant fuel). In this paper, codes computation comparison against experimental data obtained on CIP0-1 test is done for the first phase of the transient, the PCMI phase, in order to point out the strengths and weaknesses of the codes. The CIP0-1 experiment was performed with UO2 high burnup fuel in the CABRI sodium loop facility, at 280°C and low pressure (~3 bars) without boiling crisis and no failure of the fuel rod. The initial state of the rod calculated by irradiation codes are compared with measurements before the transient. Then global rod thermal behavior during the CIP0-1 test is assessed with the sodium coolant temperature measurements. The rod mechanical behavior is analyzed with the fuel and clad elongation and the clad residual hoop strain. Finally comparison of the fission gas behavior between codes is performed and compared to the measurements of the fission gas released in the experiment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

PV Inverter Testing for Momentary Cessation and Rate-of-Change-of-Frequency Events: Preprint

To understand the power system stability and develop better electromagnetic transient (EMT) models of field deployed photovoltaic (PV) inverters, it is important to characterize inverters' response to abnormal voltage and frequency scenarios. Because EMT models are not typically available for small distribution-connected PV inverters, and because inerterconnection standards historically did not specify desired ride-through behaviors, we tested two such inverters in the lab to characterize their responses to severe undervoltage events and high rate-of-change-of-frequency (ROCOF) conditions. The inverters tested were pre-IEEE 1547-2018 residential PV inverters widely used in the Hawaiian Electric territory and many other areas. The testing results for undervoltage scenarios showed that the inverter from one vendor exhibited momentary cessation while the inverter from the other vendor did not exhibit momentary cessation behavior or tripping for most of the events below the 120 ms undervoltage trip threshold duration set by IEEE 1547-2003. The testing results for ROCOF scenarios showed that the inverter from one vendor temporarily lost synchronization during ROCOF conditions while the inverter from the other vendor did not lose synchronization or cease generation for any ROCOF conditions. Both the inverters were also tested for EMT-simulated grid events with severe changes in frequency and voltage. The observed responses of the inverters were different from the simulated response of PV inverters represented the best available assumptions from pre-existing information. The results from these experiments can be used to update the inverter models used in bulk power system studies.

IEEE 1547 2018↗

Determining performance parameters of general aviation aircraft

A method for determining propeller efficiency and drag from flight tests, using relatively simple instrumentation, is under development at Mississippi State University. Flight test data from several simple maneuvers are combined to produce sufficient information to determine the desired parameters. Information obtained from the transient response of airspeed to a step change in power or drag in level flight is utilized. Theory is developed and results of preliminary computer studies and preliminary flight test are presented.

Bull, G.↗

Development of NASA/DOE NTP System Performance Models

A critical enabling technology in the evolutionary development of Nuclear Thermal Propulsion (NTP) is the ability to predict the system performance under a variety of operating conditions. The ability to predict the system performance is critical for mission analysis and for control subsystem testing, as well as for the modeling of various failure modes. Performance must be accurately predicted during steady-state and transient operation, such as start-up, shut-down and after-cooling. The development and application of verified and validated system models has the potential to reduce testing, cost and time required for the technology to again reach flight-ready status. An integrated NASA/DOE team was formed in late 1991 to develop and implement a strategy for modeling NTP systems. It is the intent of the interagency team to develop several levels of computer programs, which vary in detail, to simulate NTP systems based on either prismatic, particle or advanced fuel forms. This paper presents an overview of the models under development by the interagency team. In addition, the status of the development and validation efforts for the Level 1 steady-state parametric model is discussed.

Walton, James T.↗

Evaluating the Effects of Transient Purge Flow on Stator-Rotor Seal Performance

Abstract As modern engine designs target higher efficiencies through increased turbine inlet temperatures, critical turbine components are at increased risk of damage from conditions exceeding material melting temperatures. In particular, improperly designed underplatform hardware components are susceptible to damage when hot main gas path flow is ingested into the stator-rotor cavity. While all turbines inherently experience transients during operation, a majority of publicly available turbine studies have been executed using steady operating conditions or inherently transient “blowdown” rigs. For this reason, routine transient events are not well understood. To address this need, the present study utilized a combined experimental and computational approach. The test article is a continuous-duration, one-stage test turbine operating with true-scale engine hardware and seal geometries at engine-representative flow conditions. The nature of the continuous-duration facility uniquely supports the direct assessment of transient events through its ability to transition between steady-state operating conditions. The effects of a transient purge flow were investigated in this study to identify general trends for transient events in a full-scale engine. Results from multiple measurement techniques in the wheelspace region show an interdependence of transient purge flow with a thermal lag of the underplatform hardware. Through experiments conducted at different coolant-to-main gas path temperature ratios, the use of pressure measurements as an indicator of fully purged behavior was introduced, and a thermally driven influence on rim seal performance was quantified. The computational results show good agreement with experimental pressure measurements and provide insight into the physical mechanisms that drive the relationship between pressure and sealing effectiveness measurements observed for the tested geometry.

Engineering↗

In-circuit fault injector user's guide

A fault injector system, called an in-circuit injector, was designed and developed to facilitate fault injection experiments performed at NASA-Langley's Avionics Integration Research Lab (AIRLAB). The in-circuit fault injector (ICFI) allows fault injections to be performed on electronic systems without special test features, e.g., sockets. The system supports stuck-at-zero, stuck-at-one, and transient fault models. The ICFI system is interfaced to a VAX-11/750 minicomputer. An interface program has been developed in the VAX. The computer code required to access the interface program is presented. Also presented is the connection procedure to be followed to connect the ICFI system to a circuit under test and the ICFI front panel controls which allow manual control of fault injections.

Padilla, Peter A.↗

Failure analysis of a cooling pump using modal and vibration analysis

Four pumps redundantly supply cooling water to a system. All four pumps underwent maintenance during a recently scheduled downtime. During preliminary evaluation following maintenance, one pump, the subject of this document, exhibited higher vibration levels compared to the other three pumps. The pump underwent further performance testing to rule out potential damage resulting from the higher vibration. Vibration analysis and modal analysis including steady state spectrum, operational deflection shape, run up transients, and modal impact have been utilized to identify dynamic characteristics that could contribute to the increased vibration levels. This article will cover the testing setup, methodology, analysis results, and recommendations.

42 ENGINEERING↗

Dynamic Modeling and Testing of MSRR-1 for Use in Microgravity Environments Analysis

Delicate microgravity science is unlikely to succeed on the International Space Station if vibratory and transient disturbers corrupt the environment. An analytical approach to compute the on-orbit acceleration environment at science experiment locations within a standard payload rack resulting from these disturbers is presented. This approach has been grounded by correlation and comparison to test verified transfer functions. The method combines the results of finite element and statistical energy analysis using tested damping and modal characteristics to provide a reasonable approximation of the total root-mean-square (RMS) acceleration spectra at the interface to microgravity science experiment hardware.

Gattis, Christy↗

Effects of Intrusive Confining Units on Groundwater Flow at Pahute Mesa, Nevada National Security Site

Geological, geophysical, hydrogeological, and hydrological evidence indicates that feeder dikes to rhyolitic lava flows may play a role as confining units in the groundwater flow system underlying the Pahute Mesa (PM) area of underground nuclear testing at the Nevada National Security Site (NNSS) (Figure 1). Of geological significance, the PM testing area is largely situated within the Silent Canyon caldera complex (SCCC), which includes both tuffs and lavas that were fed by (and are connected to) intrusive rock units such as feeder dikes prior to and during volcanic eruptions (Orkild et al., 1968; Byers et al., 1976a). Groundwater modeling results presented in this report support extension of “pool-dam” and “breach scenario” concepts presented in Jackson and Fenelon (2018) and Jackson et al. (2021) to low-permeability intrusive confining units (ICUs) such as feeder dikes that are expected to dissect and ring silicic calderas. As laterally extensive, steeply-dipping, and sub-parallel planar structures, ICUs may further compartmentalize groundwater flow in some areas of the volcanic aquifer system at PM. ICUs may explain unusually high horizontal hydraulic gradient southwest of Cheshire. Breaching of an ICU within which the Cheshire test was emplaced may explain changes in water levels before and after the Cheshire test was detonated in the U-20n emplacement hole on 2/14/76 (USDOE, 2015b). This analysis of the effects of ICUs on groundwater flow at PM addresses a need to evaluate uncertainty in the conceptual model or structural aspects of hydrologic source term (HST) or corrective action unit (CAU) models for groundwater flow and contaminant transport (FFACO, 1996, as amended). At Cheshire and possibly other test locations at PM, downgradient extent of radionuclide contamination may be overpredicted by not including the confining effects of ICUs. On the other hand, contaminant extent may be underpredicted by not considering transient flow effects and/or the re-equilibrated flow field caused by breaching of an ICU by an underground nuclear test. Near Cheshire, the effects of ICUs may be most apparent and impactful to the groundwater flow system at PM because of an unusual combination of thickness, extent, and frequency of dikes transecting the saturated CHLFA4 aquifer and feeding into the overlying unsaturated rhyolite lava of Windy Wash. Chapters 2, 3, and 4 present geological, geophysical, hydrogeological, and hydrological evidence for ICUs at PM. Chapters 5 and 6 examine effects of ICUs on groundwater flow including analysis by groundwater modeling.

54 ENVIRONMENTAL SCIENCES↗