Search NASA⌕ Search

SEARCH · Search NASA

Results for “Utility rate structure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Quantification of Energy Savings and Demand Reduction for a Heat Pump Integrated with Thermal Energy Storage (Final Report)

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries or installing new peaking power plants. Stakeholders and policy makers across the United States have expressed interests in promoting TES, as demonstrated by the US Department of Energy’s Grid-Interactive Efficient Buildings program and the efforts of various state legislatures. However, the cost value provided by TES are unclear. If reliable cost benefits were determined, stakeholders would have a clearer picture of the financial returns that can be gained from their investment in TES. The study in this report is conducted by ORNL with collaboration with Emerson the Helix Innovation Center. In the first part of this report, EnergyPlus was used to perform whole-building simulations for two residential buildings in Indianapolis and Atlanta. The HVAC system in both buildings were equipped with phase change material TES. The TES tank was charged in off-peak hours and discharged in peak hours to perform load shifting. First, the economic value implied by existing time-of-use (TOU) rates offered by utility companies was analyzed via whole-building simulation. Second, existing demand reduction (DR) incentives sourced from 3 different electrical grid administrators (i.e., California, Texas, and New England region) were surveyed to determine their implied value. The study suggests that the traditional value analysis that focuses on ROI for the building owner significantly undervalues TES technology making economic viability difficult. A more comprehensive value analysis that includes peak demand management and deferred capital for peaking power plants shows that TES should be economically viable but here the value is greater for the utility and requires large market penetration and aggregation to fully realize the benefits. Therefore, to facilitate commercialization, new business models are needed that include a broader range of stakeholders and distribute the value of TES proportionally. In the 2 nd part of this project, the benefits of a novel phase change material (PCM) integrated heat pump configuration were evaluated via detailed component based simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation. To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ASSESSMENT OF THE POTENTIAL FOR HYDROGEN GENERATION DURING GROUTING OPERATIONS IN THE R- AND P-REACTOR VESSELS

The R- and P-reactor buildings were retired from service and are now being prepared for deactivation and decommissioning (D&D). D&D activities will consist primarily of immobilizing contaminated components and structures in a grout-like formulation. Aluminum corrodes very rapidly when it comes in contact with the alkaline grout materials and as a result produces hydrogen gas. To address this potential deflagration/explosion hazard, the Materials Science and Technology Directorate (MS&T) of the Savannah River National Laboratory (SRNL) has been requested to review and evaluate existing experimental and analytical studies of this issue to determine if any process constraints on the chemistry of the fill material and the fill operation are necessary. Various options exist for the type of grout material that may be used for D&D of the reactor vessels. The grout formulation options include ceramicrete (pH 6-8), low pH portland cement + silica fume grout (pH 10.4), or Portland cement grout (pH 12.5). The assessment concluded that either ceramicrete or the silica fume grout may be used to safely grout the P-reactor vessel. The risk of accumulation of a flammable mixture of hydrogen between the grout-air interface and the top of the reactor is very low. Portland cement grout, on the other hand, for the same range of process parameters does not provide a significant margin of safety against the accumulation of flammable gas in the reactor vessel during grouting operations in the P-reactor vessel. It is recommended that this grout not be utilized for this task. The R-reactor vessel contains significantly less aluminum and thus a Portland cement grout may be considered as well. For example, if the grout fill rate is less than 1 inch/min and the grout temperature is maintained at 70 C or less, the risk of hydrogen accumulation in the R-reactor vessel is very low for the Portland cement. Alternatively, if the grout fill rate is less than 0.5 inch/min and the grout is maintained at a temperature of 80 C, the risk will again be very low. Although these calculations are conservative, there are some measures that may be taken to further minimize the potential for hydrogen evolution. (1) Minimize the temperature of the grout as much as practical. Lower temperatures will mean lower hydrogen generation rates. For P-reactor, grout temperatures less than 100 C should provide an adequate safety margin for the pH 8 and pH 10.4 grout formulations. For R-reactor, grout temperatures less than 70 C or 80 C will provide an adequate safety margin for the Portland cement. The other grout formulations are also viable options for R-reactor. (2) Minimize the grout fill rate as much as practical. Lowering the fill rate takes advantage of passivation of the aluminum components and hence lower hydrogen generation rates. For P-reactor, fill rates that are less than 2 inches/min for the ceramicrete and the silica fume grouts will reduce the chance of significant hydrogen accumulation. For R-reactor, fill rates less than 1 inch/min will again minimize the risk of hydrogen accumulation. (3) Ventilate the building as much as practical (e.g., leave doors open) to further disperse hydrogen. The volumetric hydrogen generation rates in the P-reactor vessel, however, are low for the pH 8 and pH 10.4 grout, (i.e., less than 0.32 ft{sup 3}/min). If further walk-down inspections of the reactor vessels suggest an increase in the actual areal density of aluminum, the calculations should be re-visited.

08 HYDROGEN↗

Automatic Energy Schemes for High Performance Applications

Although high-performance computing traditionally focuses on the efficient execution of large-scale applications, both energy and power have become critical concerns when approaching exascale. Drastic increases in the power consumption of supercomputers affect significantly their operating costs and failure rates. In modern microprocessor architectures, equipped with dynamic voltage and frequency scaling (DVFS) and CPU clock modulation (throttling), the power consumption may be controlled in software. Additionally, network interconnect, such as Infiniband, may be exploited to maximize energy savings while the application performance loss and frequency switching overheads must be carefully balanced. This work first studies two important collective communication operations, all-to-all and allgather and proposes energy saving strategies on the per-call basis. Next, it targets point-to-point communications to group them into phases and apply frequency scaling to them to save energy by exploiting the architectural and communication stalls. Finally, it proposes an automatic runtime system which combines both collective and point-to-point communications into phases, and applies throttling to them apart from DVFS to maximize energy savings. The experimental results are presented for NAS parallel benchmark problems as well as for the realistic parallel electronic structure calculations performed by the widely used quantum chemistry package GAMESS. Close to the maximum energy savings were obtained with a substantially low performance loss on the given platform.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Baseload Nitrate Salt Central Receiver Power Plant Design (Final Report)

The objectives of the work were to demonstrate that a 100 MWe central receiver plant, using nitrate salt as the receiver coolant, thermal storage medium, and heat transport fluid in the steam generator, can 1) operate, at full load, for 6,400 hours each year using only solar energy, and 2) satisfy the DOE levelized energy cost goal of $0.09/kWhe (real 2009 $). To achieve these objectives the work incorporated a large range of tasks relating to many different aspects of a molten salt tower plant. The first Phase of the project focused on developing a baseline design for a Molten Salt Tower and validating areas for improvement. Tasks included a market study, receiver design, heat exchanger design, preliminary heliostat design, solar field optimization, baseline system design including PFDs and P&IDs and detailed cost estimate. The baseline plant met the initial goal of less than $0.14/kWhe, and reinforced the need to reduce costs in several key areas to reach the overall $0.09/kWhe goal. The major improvements identified from Phase I were: 1) higher temperature salt to improve cycle efficiency and reduce storage requirements, 2) an improved receiver coating to increase the efficiency of the receiver, 3) a large receiver design to maximize storage and meet the baseload hours objective, and 4) lower cost heliostat field. The second Phase of the project looked at advancing the baseline tower with the identified improvements and included key prototypes. To validate increasing the standard solar salt temperature to 600 °C a dynamic test was conducted at Sandia. The results ultimately proved the hypothesis incorrect and showed high oxide production and corrosion rates. The results lead to further testing of systems to mitigate the oxide production to be able to increase the salt temperature for a commercial plant. Foster Wheeler worked on the receiver design in both Phase I and Phase II looking at both design and lowering costs utilizing commercial fossil boiler manufacturing. The cost and design goals for the project were met with this task, but the most interesting results had to do with defining the failure modes and looking at a “shakedown analysis” of the combined creep-fatigue failure. A separate task also looked at improving the absorber coatings on the receiver tubes that would improve the efficiency of the receiver. Significant progress was made on developing a novel paint with a high absorptivity that was on par with the current Pyromark, but shows additional potential to be optimized further. Although the coating did not meet the emissivity goals, preliminary testing the new paint shows potential to be much more durable, and potential to improve the receiver efficiency through a higher average absorptivity over the lifetime. Additional coatings were also designed and modeled results meet the project goals, but were not tested. Testing for low cycle fatigue of the full length receiver tubes was designed and constructed, but is still currently undergoing testing. A novel small heliostat was developed through an extensive brainstorming and down select. The concept was then detailed further with inputs from component testing and eventually a full prototype was built and tested. This task met or exceeded the accuracy and structure goals and also beat the cost goal. This provides a significant solar field costs savings for Abengoa that will be developed further to be used in future commercial plants. Ultimately the $0.09/kWhe (real 2009 $) and 6,400 hours goals of the project were met.

14 SOLAR ENERGY↗

LLNL HEPA Filter Support of Nuclear Facility Safety R&D (FY12)

The ceramic HEPA filter project has been a successful and innovative project. This report contains information from the work from FY12 funding, as well as remaining FY11 funding. Of note, a total of 12 patents for the ceramic HEPA filter program have been filed, and an additional record of invention has been prepared with a provisional patent to follow. This project supports development of a ceramic HEPA filter technology to benefit DOE nuclear facilities by providing lower life-cycle costs and reducing or eliminating costs associated with Safety Class and Safety Significant systems in nuclear facilities. The satisfactory performance of ceramic filters in a fire could significantly reduce costs of support systems associated with mitigating a release, such as fire suppression, fire detection and alarm, and internal building structure. In nuclear safety, the best way to provide protection to public, workers and the environment is to provide a barrier between the hazard and the receptors. A passive engineered design feature is the best barrier for that purpose. Advanced ceramic HEPA filters provide an excellent barrier between radioactive material in a nuclear facility and everything downwind. Both university (Cal Poly) student teams did very well. As summarized in this report, they successfully added and upgraded instrumentation and controls to the High Temperature Test Unit (HTTU) for the ceramic filter project. They also succeeded in adding viewing ports, remotely controlled closed circuit television, a flame impingement system and a helium filter gasket leak detection system. Details can be found in Ref. 3 - 6. The HTTU has flexible capabilities and can also be used to test other types of filters or filter components in the future, if so desired. At LLNL, research to improve filter media coating (Fig. 1) is being conducted to maintain filtration efficiency while improving performance (reducing pressure drop). Improvements in the individual filter element are necessary to maintain filtration efficiency while decreasing pressure drop. The path forward for an optimal ceramic HEPA filter meeting DOE’s needs is to improve the filtration media. This task utilized the LLNL/DOE developed innovations along with progress in previous activities to prepare multiple ceramic filter elements and refine the technical details for depositing advanced filtration materials to the ceramic filter to meet desired filter performance. The ceramics filter elements were tested for pressure drop at the required air flow rate using an air flow test system. The filtration efficiency and pressure drop of the ceramic filter elements will be measured as part of the development process.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Voltron Compatible Whole Building Root-Fault Detection and Diagnosis

Buildings consume more than 40% of primary energy in the U.S. Malfunctioning sensors, components, and control systems, as well as degrading components in Heating, Ventilating and Air-conditioning (HVAC) and lighting systems are main reasons for energy waste and unsatisfactory indoor environment. Field studies have shown that an energy saving of 5-30% of total building energy consumption and improved indoor air quality can be achieved by simply applying automated fault detection and diagnosis (AFDD), followed by corrections even if these are not done in real time. Extensive research has been made on the development of component level AFDD tools in the past two decades. However, in recent years, the development of method for a whole building level AFDD has received much attention. Here, a whole building fault refers to a fault happening in one subsystem but impact on more than one subsystems, or has a significant impact on building performances, such as building’s energy consumption. Existing component level AFDD tools could fail to detect or give false alarm for faults that trigger abnormalities in multiple subsystems. Isolating such whole building faults, which have impacts on multiple subsystems, is also challenging by simply using component based AFDD solutions. On the other hand, it might be more cost-effective for medium- or small-sized commercial buildings that have subsystems (e.g. primary cooling subsystem, air loop subsystem, heating subsystem, lighting subsystem, etc.) to install one whole building level AFDD tool, rather than many component level AFDD tools, to focus on significant faults. The focus of this project is firstly to provide training opportunities in building AFDD research area for undergraduate students and to develop a workforce pipeline in building sciences. The objective of the proposed research activities is to develop cost-effective and scalable AFDD solutions for whole building level faults. The developed AFDD solution is VOLTTRONTM compatible to further increase its plug-n-play capacity and the market penetration. VOLTTRONTM is an open-source innovative distributed control and sensing software platform developed by the Pacific Northwest National Laboratory. A VOLTTRONTM compatible AFDD tool brings the benefits such as low-cost deployment, and better building to grid integration, etc. The performance of the developed whole building AFDD tools is evaluated using data collected from a mixed-use medium-sized university campus building. Another significant goal of this project is to engage undergraduate students in research activities and expose them to building control and AFDD fields. A demonstration building – Nesbitt Hall at Drexel University is identified for this study. This demonstration building has a typical HVAC system configuration, which includes a water-cooled chiller system, three variable air volume (VAV) air handling unit (AHU) systems, and a hydronic heating system. Faults, that are expected to have a whole building level impact, are artificially implemented in this demonstration building for three different seasons. Building data have been collected in this project, which include fault free building automation system (BAS) data and BAS data that contain system behaviors caused by artificially implemented and naturally occurred faults. These collected data are used to evaluate the developed whole building AFDD tools. A data-driven method, which includes a weather and schedule-based pattern matching (WPM) method and Feature based Principal Component Analysis (FPCA) method, is developed for whole building level fault detection. Parameter sensitivity tests, including snapshot window size, data sample searching pool size, etc., are implemented to evaluate the impacts of various WPM-FPCA parameters. A data-driven and expert knowledge/rule-based method using Bayesian Network (BN) and WPM is developed for whole building level fault diagnosis. The developed WPM-BN method, which includes a two-layer BN structure model and BN parameters, are either learned from baseline data or developed from expert knowledge. The developed whole building AFDD tools are evaluated using BAS data collected from the demonstration building. Using the evaluation data set, the WPM-FPCA fault detection method is evaluated under two different Principle Component (PC) retention rates, i.e., 0.65 retention rate and 0.95 retention rate. It is observed that when using 0.65 PC retention rate, the WPM-FPCA fault detection method achieves a 79% fault detection rate (this rate reaches to 85% when including the six make-up fault test cases discussed in the next bullet), while when using 0.95 PC retention rate, the WPM-FPCA fault detection method achieves 100% fault detection rate (this rate remains to be 100% when including the six make-up fault test cases). Under both PC retention rates, the WPM-FPCA fault detection method demonstrates 0% false alarm rates. Using the evaluation data set, the developed WPM-BN fault diagnosis method has successfully diagnosed thirteen (13) faults out of the fourteen (14) fault test cases. The one mis-diagnosed case exhibits fewer fault symptoms in different subsystems, when compared with other fault test cases. Overall speaking, the developed whole building AFDD solutions demonstrate satisfactory fault detection/diagnosis accuracy with very low false alarm rate. Lastly, a survey and market study has been performed to understand the existing AFDD market, including its gaps and needs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhancing the electron mobility in Si-doped (010) β-Ga 2 O 3 films with low-temperature buffer layers

We demonstrate a new substrate cleaning and buffer growth scheme in β-Ga 2 O 3 epitaxial thin films using metal–organic vapor phase epitaxy (MOVPE). For the channel structure, a low-temperature (LT, 600 °C) un-doped Ga 2 O 3 buffer was grown, followed by a transition layer to a high-temperature (HT, 810 °C) Si-doped Ga 2 O 3 channel layers without growth interruption. The (010) Ga 2 O 3 Fe-doped substrate cleaning uses solvent cleaning, followed by additional hydrofluoric acid (49% in water) treatment for 30 min before the epilayer growth. This step is shown to compensate the parasitic Si channel at the epilayer–substrate interface that originates from the substrate polishing process or contamination from the ambient. From secondary ion mass spectroscopy (SIMS) analysis, the Si peak atomic density at the substrate interface is found to be several times lower than the Fe atomic density in the substrate—indicating full compensation. The elimination of the parasitic electron channel at the epi–substrate interface was also verified by electrical (capacitance–voltage profiling) measurements. In the LT-grown (600 °C) buffer layers, it is seen that the Fe forward decay tail from the substrate is very sharp, with a decay rate of ∼9 nm/dec. X-ray off-axis rocking curve ω-scans show very narrow full width at half maximum (FWHM) values, similar to the as-received substrates. These channels show record high electron mobility in the range of 196–85 cm 2 /V⋅s in unintentionally doped and Si-doped films in the doping range of 2 × 10 16 –1 × 10 20 cm −3 . Si delta-doped channels were also grown utilizing this substrate cleaning and the hybrid LT buffers. Record high electron Hall mobility of 110 cm 2 /V⋅s was measured for sheet charge density of 9.2 × 10 12 cm −2 . This substrate cleaning, combined with the LT buffer scheme, shows the potential of designing Si-doped β-Ga 2 O 3 channels with exceptional transport properties for high-performance Ga 2 O 3 -based electron devices.

Bhattacharyya, Arkka↗

Metalorganic chemical vapor deposition of ZnGeN 2 films on GaN: effects of cation stoichiometry on surface morphology and crystallinity

Novel optoelectronic device designs based on the heterostructures of III-N and II-IV-N 2 are promising to advance device performance significantly. For example, by utilizing InGaN-ZnGeN 2 quantum well (QW) structures instead of pure InGaN, the band structure engineering in the QW active region can lead to improved electron-hole wavefunction overlap, and thus enhance the radiative efficiency for photon generation. These novel heterostructures have great potential to address the current challenge of low quantum efficiency in InGaN QW based light emitting diodes emitting in green and beyond. The materials development of ZnGeN 2 is still at an early stage as compared to the much matured GaN material system. In an ideal octet rule preserving ordered structure of ZnGeN 2 , every N atom is coordinated by exactly two Zn and two Ge atoms. However, local violation of octet rule can be caused by non-ideal coordination of N by the cations. The disordered structure is thermodynamically less favorable but can still be achieved, for example, in kinetics-limited growth regime. The ordered ZnGeN 2 has a bandgap very close to that of GaN (~3.4 eV) and a lattice mismatch of <0.1% with GaN. Interestingly, the valence band of ZnGeN 2 has been predicted to be ~1 eV above that of GaN, which has inspired novel designs for high efficiency light emitters. In this work, we investigated the metalorganic chemical vapor deposition (MOCVD) of ZnGeN 2 films on GaN/c-sapphire templates. Diethylzinc (DEZn), germane (GeH4) and ammonia were used as the precursors for Zn, Ge and N, respectively. A systematic study was conducted to investigate the cation stoichiometry as a function of growth temperature (TG), total reactor pressure (P) and DEZn/GeH 4 molar flow rate ratio (RII/IV). Under the investigated growth window, the Zn/(Zn+Ge) composition in the films, determined from energy dispersive X-ray spectroscopy, decreased monotonically with increase in TG but increased with increase in P and RII/IV. Atom probe tomography data did not indicate the presence of any secondary phases such as Zn 3 N 2 or Ge 3 N 4 . The surface morphology and crystallinity of the grown films had strong correlation with the Zn/(Zn+Ge) composition. The scanning electron microscopy images showed that the near-stoichiometric films have planar surfaces whereas Zn-rich films had crystallites on their surface and the Zn-poor films had faceted surface. Scanning transmission electron microscopy (STEM) imaging revealed that the Zn-rich and Zn-poor films have columnar and filament-like morphology, respectively, whereas the near-stoichiometric films have continuous film-like cross-sectional morphology. TEM nano-diffraction patterns as well as X-ray diffraction 2θ-ω scan profiles indicate that the near stoichiometric films are single crystalline. Nano-diffraction pattern of the stoichiometric films resembled that of a disordered ZnGeN 2 structure. Room temperature Raman spectra of near-stoichiometric films showed only the phonon density of states like features of a cation disordered ZnGeN 2 . Cathodoluminescence and photoluminescence spectra measured at different temperatures had similar features with peak emission wavelength at ~ 2 eV. In conclusion, the stoichiometry of ZnGeN 2 films can be widely tuned by tuning the MOCVD growth parameters. The surface morphology and the crystallinity of the films were found to have strong correlation with the Zn/(Zn+Ge) composition. The stoichiometric ZnGeN 2 films grown on GaN were demonstrated with uniform surface morphology and high crystalline quality. The results from this work will provide pathway to implement ZnGeN 2 in device structures.

Karim, Md Rezaul↗

Preparation of MgCo 2 O 4 /graphite composites as cathode materials for magnesium-ion batteries

Magnesium-ion batteries are fabricated with MgCo 2 O 4 /graphite composites as the cathode material. MgCo 2 O 4 nanoparticles are arranged using a co-precipitation method. A three-dimensional mixing process is utilized to mechanically decorate MgCo 2 O 4 nanoparticles on graphite particles. The MgCo 2 O 4 spinel crystals of size ranging from 20 to 70 nm on micrometer-sized graphite chunks are analyzed by using X-ray diffraction and scanning electron microscopy. The electrochemical properties of the as-prepared composites are well characterized by cyclic voltammetry, charge and discharge cycling, and electrochemical impedance spectroscopy (EIS). Interestingly, the MgCo 2 O 4 /graphite composite with a relatively low proportion of MgCo 2 O 4 , compared with the other as-prepared composites, achieves the highest specific capacity of 180 mAh g –1 at a C rate of 0.05 C. EIS results suggest that the electrical conductivity of the composite material is an increasing function of the graphite proportion. The superior performance of the MgCo 2 O 4 /graphite composite could be ascribed to the decoration of nanosized MgCo 2 O 4 particles as well as to the increased conductivity provided by graphite.

25 ENERGY STORAGE↗

Magnetic field dependence of the martensitic transition and magnetocaloric effects in Ni 49 BiMn 35 In 15

The structural, magnetic, and magnetocaloric properties of the Bi-doped Heusler alloy Ni 49 BiMn 35 In 15 have been investigated using room temperature X-ray diffraction (XRD) and magnetization measurements in a temperature interval of 5-400 K. The alloy at room temperature was found to be in a mixture of a high temperature austenite phase (AP) and a low temperature martensite phase (MP). A drastic shift in the martensitic transition temperature at the rate of 16 K/T from 197 K to lower temperatures was observed. A kinetic arrest phenomenon of the AP was observed in the magnetization and electrical resistivity measurements during field-cooled (FC) measurements at 5T. A metamagnetic behavior characterized by a jump in magnetization in the isothermal M ( H ) curves near T M was observed. The maximum value of the magnetic entropy change and refrigerant capacity at Curie temperature were found to be 5.5 Jkg -1 K -1 and 312 Jkg -1 for μ o Δ H = 5T, respectively. A large magnetoresistance value of -56% was found near the martensitic transition.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Methanol Synthesis from H-2 and CO2 on a Mo6S8 Cluster: A Density Functional Study

Catalytic CO{sub 2} hydrogenation to methanol has received considerable attention as an effective way to utilize CO{sub 2}. In this paper, density functional theory was employed to investigate the methanol synthesis from CO{sub 2} and H{sub 2} on a Mo{sub 6}S{sub 8} cluster. The Mo{sub 6}S{sub 8} cluster is the structural building block of the Chevrel phase of molybdenum sulfide, and has a cagelike structure with an octahedral Mo{sub 6} metallic core. Our calculations indicate that the preferred catalytic pathway for methanol synthesis on the Mo{sub 6}S{sub 8} cluster is very different from that of bulklike MoS{sub 2}. MoS{sub 2} promotes the C-O scission of H{sub x}CO intermediates, and therefore, only hydrocarbons are produced. The lower S/Mo ratio for the cluster compared to stoichiometric MoS{sub 2} might be expected to lead to higher activity because more low-coordinated Mo sites are available for reaction. However, our results show that the Mo{sub 6}S{sub 8} cluster is not as reactive as bulk MoS{sub 2} because it is unable to break the C-O bond of H{sub x}CO intermediates and therefore cannot produce hydrocarbons. Yet, the Mo{sub 6}S{sub 8} cluster is predicted to have moderate activity for converting CO{sub 2} and H{sub 2} to methanol. The overall reaction pathway involves the reverse water-gas shift reaction (CO{sub 2} + H{sub 2} {yields} CO + H{sub 2}O), followed by CO hydrogenation via HCO (CO + 2H{sub 2} {yields} CH{sub 3}OH) to form methanol. The rate-limiting step is CO hydrogenation to the HCO with a calculated barrier of +1 eV. This barrier is much lower than that calculated for a comparably sized Cu nanoparticle, which is the prototypical metal catalyst used for methanol synthesis from syngas (CO + H{sub 2}). Both the Mo and S sites participate in the reaction with CO{sub 2}, CO, and CH{sub x}O preferentially binding to the Mo sites, whereas S atoms facilitate H-H bond cleavage by forming relatively strong S-H bonds. Our study reveals that the unexpected activity of the Mo{sub 6}S{sub 8} cluster is the result of the interplay between shifts in the Mo d-band and S p-band and its unique cagelike geometry.

10 SYNTHETIC FUELS↗

Achievable Performance and Effective Interrogator Design for SAW RFID Sensor Tags

For many NASA missions, remote sensing is a critical application that supports activities such as environmental monitoring, planetary science, structural shape and health monitoring, non-destructive evaluation, etc. The utility of the remote sensing devices themselves is greatly increased if they are passive that is, they do not require any on-board power supply such as batteries and if they can be identified uniquely during the sensor interrogation process. Additional passive sensor characteristics that enable greater utilization in space applications are small size and weight, long read ranges with low interrogator power, ruggedness, and operability in extreme environments (vacuum, extreme high/low temperature, high radiation, etc.) In this paper, we consider one very promising passive sensor technology, called surface acoustic wave (SAW) radio-frequency identification (RFID), that satisfies all of these criteria. Although SAW RFID tags have great potential for use in numerous space-based remote sensing applications, the limited collision resolution capability of current generation tags limits the performance in a cluttered sensing environment. That is, as more SAW-based sensors are added to the environment, numerous tag responses are superimposed at the receiver and decoding all or even a subset of the telemetry becomes increasingly difficult. Background clutter generated by reflectors other than the sensors themselves is also a problem, as is multipath interference and signal distortion, but the limiting factor in many remote sensing applications can be expected to be tag mutual interference. This problem may be greatly mitigated by proper design of the SAW tag waveform, but that remains an open research problem, and in the meantime, several other related questions remain to be answered including: What are the fundamental relationships between tag parameters such as bit-rate, time-bandwidth-product, SNR, and achievable collision resolution? What are the differences in optimal or near-optimal interrogator designs between noise-limited environments and interference-limited environments? What are the performance characteristics of different interrogator designs in term of parameters such as transmitter power level, range, and number of interfering tags? In this paper, we present the results of a research effort aimed at providing at least partial answers to all of these questions.

Barton, Richard J.↗

SO{sub 2} Retention by CaO-Based Sorbent Spent in CO{sub 2} Looping Cycles

CaO-based looping cycles are promising processes for CO{sub 2} Capture from both syngas and flue gas. The technology is based on cyclical carbonation of CaO and regeneration of CaCO{sub 3} in a dual fluidized-bed reactor to produce a pure CO{sub 2} stream suitable for sequestration. Use of spent sorbent from CO{sub 2} looping cycles for SO{sub 2} capture is investigated. Three limestones were investigated: Kelly Rock (Canada), La Blanca (Spain), and Katowice (Poland, Upper Silesia). Carbonation/calcination cycles were performed in a tube furnace with both the original limestones and samples thermally pretreated for different times (i.e., sintered). The spent sorbent samples were sulfated in a thermogravimetric analyzer (TGA). The changes in the resulting sorbent pore structure were then investigated using mercury porosimetry. It has been shown that the sulfation rates of both thermally pretreated and spent sorbent samples are lower in comparison with those of the original samples. However, final conversions of both spent and pretreated sorbents after longer sulfation time were comparable or higher than those observed for the original sorbents under comparable conditions. Maximum sulfation levels strongly depend on sorbent porosity and pore surface area. The results showed that spent sorbent samples from CO{sub 2} looping cycles can be used as sorbents for SO{sub 2} retention in cases where significant porosity loss does not occur during CO{sub 2} reaction cycles. In the case of spent Kelly Rock and Katowice samples, sorbent particles are practically uniformly sulfated, achieving final conversions that are determined by the total pore volume available for the bulky CaSO{sub 4} product.

01 COAL, LIGNITE, AND PEAT↗

National energy savings potential of cellular shades: A measurement and simulation study

Windows are major contributors to energy demand in residential homes because of their inferior thermal resistance compared with the opaque envelope, and sometimes from unwanted solar heat gain. Window attachments can help mitigate the energy demand by controlling the solar heat gains and enhancing window thermal resistance. Cellular shades have the potential of superior thermal performance compared with generic shades because of its honeycomb structure. Here, in this study, the team analyzed the energy savings potential of cellular shades in residential homes via experimental testing for two heating seasons and energy simulations. Five shading devices—three single-cell and two double cellular/cell-in-cell shades—were used to compare the performance with generic horizontal venetian blinds using two nearly identical side-by-side rooms in a residential home. The experimental testing showed daily heating energy savings in the range of 17%–36% compared with the case without shades. The experimental testing data also exhibited improvements in thermal comfort when using cellular shades. Additionally, energy simulations were performed to evaluate the energy savings potential of the cellular shades using a residential prototype home, which demonstrated energy savings up to 9 kWh/m2/year in cold climates. The total site energy savings for heating and cooling from cellular shades was up to ~9% for the home with a heat pump and up to ~15% for a home with a gas furnace compared with cases without any shading devices. The energy savings at a national scale were up to 14.6 TWh assuming a 20% penetration rate in residential homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DEVIATIONS FROM THE SCHMIDT-KENNICUTT RELATIONS DURING EARLY GALAXY EVOLUTION

We utilize detailed time-varying models of the coupled evolution of stars and the H I, H{sub 2}, and CO-bright H{sub 2} gas phases in galaxy-sized numerical simulations to explore the evolution of gas-rich and/or metal-poor systems, which are expected to be numerous in the early universe. The inclusion of the CO-bright H{sub 2} gas phase and the realistic rendering of star formation as an H{sub 2}-regulated process (and the new feedback processes that this entails) allow the most realistic tracking of strongly evolving galaxies and much better comparison with observations. We find that while galaxies eventually settle into states conforming to the Schmidt-Kennicutt (S-K) relations, significant and systematic deviations of their star formation rates (SFRs) from the latter occur, and are especially pronounced and prolonged for metal-poor systems. The largest such deviations occur for gas-rich galaxies during not only the early evolutionary stages but also during brief periods at later stages. Given that gas-rich and/or metal-poor states of present-epoch galaxies are expected in the early universe while a much larger number of mergers frequently reset non-isolated systems to gas-rich states, even brief periods of sustained deviations of their SFRs from those expected from the S-K relations may come to characterize significant periods of their stellar mass built-up. This indicates potentially serious limitations of S-K-type relations as reliable sub-grid elements of star formation physics in simulations of structure formation in the early universe. We anticipate that galaxies with marked deviations from the S-K relations will be found at high redshifts as unbiased inventories of total gas mass become possible with ALMA and the EVLA.

79 ASTRONOMY AND ASTROPHYSICS↗

Geologic Modeling and Simulation Report for the Aquistore Project

The Plains CO 2 Reduction (PCOR) Partnership, through the Energy & Environmental Research Center (EERC), has been supporting, and continues to support, the Petroleum Technology Research Centre (PTRC) Aquistore project. This support has been in the form of geologic characterization, involvement in the Science and Engineering Research Committee (SERC), involvement in public outreach, developing geologic models and running predictive simulations on the expected injection program at the site. The Aquistore project is part of the world’s first commercial postcombustion carbon capture, utilization, and storage project from a coal-fired power-generating facility, the SaskPower Boundary Dam, located in Saskatchewan, Canada, and will be acting as a storage site for a portion of the captured CO 2 from the Boundary Dam power plant. The Aquistore site includes one injection well and a 152-meter offset observation well. Both wells were drilled and completed in the Deadwood and Black Island Formations. At the time of this report, injection at the Aquistore site is anticipated to begin in late 2014. To better understand the storage implications of injecting carbon dioxide (CO 2 ) at the Aquistore site, the EERC has constructed P10, P50, and P90 geologic model realizations and run three new predictive simulation scenarios on each realization. These models and simulations were constructed to better understand both operational and geologic uncertainties that may exist at the Aquistore site. The geologic model realizations and simulations are an update to those completed in the original report entitled “Geologic Modeling and Simulation Report for the Aquistore Project,” Deliverable D93, approved in March 2014. In this update, the same fine-scale model extent of the 34-square-kilometer PTRC 3-D seismic survey area, with higher structural resolution, was continually used for the uncertainty analysis. A low (P10), mid (P50), and high volumetric (P90) case for the amount of pore volume accessible to store the potential injected CO 2 was ranked based on certain deviation variations of model-building parameters, including effective porosity and net-to-gross reservoir, in six sand units of the study area. Three cases with various injection rate and period schemes were simulated based on uncertainty models P10, P50, and P90.

54 ENVIRONMENTAL SCIENCES↗

Use of Generalized Fluid System Simulation Program (GFSSP) for Teaching and Performing Senior Design Projects at the Educational Institutions

This paper describes the experience of the authors in using the Generalized Fluid System Simulation Program (GFSSP) in teaching Design of Thermal Systems class at University of Alabama in Huntsville. GFSSP is a finite volume based thermo-fluid system network analysis code, developed at NASA/Marshall Space Flight Center, and is extensively used in NASA, Department of Defense, and aerospace industries for propulsion system design, analysis, and performance evaluation. The educational version of GFSSP is freely available to all US higher education institutions. The main purpose of the paper is to illustrate the utilization of this user-friendly code for the thermal systems design and fluid engineering courses and to encourage the instructors to utilize the code for the class assignments as well as senior design projects. The need for a generalized computer program for thermofluid analysis in a flow network has been felt for a long time in aerospace industries. Designers of thermofluid systems often need to know pressures, temperatures, flow rates, concentrations, and heat transfer rates at different parts of a flow circuit for steady state or transient conditions. Such applications occur in propulsion systems for tank pressurization, internal flow analysis of rocket engine turbopumps, chilldown of cryogenic tanks and transfer lines, and many other applications of gas-liquid systems involving fluid transients and conjugate heat and mass transfer. Computer resource requirements to perform time-dependent, three-dimensional Navier-Stokes computational fluid dynamic (CFD) analysis of such systems are prohibitive and therefore are not practical. Available commercial codes are generally suitable for steady state, single-phase incompressible flow. Because of the proprietary nature of such codes, it is not possible to extend their capability to satisfy the above-mentioned needs. Therefore, the Generalized Fluid System Simulation Program (GFSSP1) has been developed at NASA Marshall Space Flight Center (MSFC) as a general fluid flow system solver capable of handling phase changes, compressibility, mixture thermodynamics and transient operations. It also includes the capability to model external body forces such as gravity and centrifugal effects in a complex flow network. The objectives of GFSSP development are: a) to develop a robust and efficient numerical algorithm to solve a system of equations describing a flow network containing phase changes, mixing, and rotation; and b) to implement the algorithm in a structured, easy-to-use computer program. The analysis of thermofluid dynamics in a complex network requires resolution of the system into fluid nodes and branches, and solid nodes and conductors as shown in Figure 1. Figure 1 shows a schematic and GFSSP flow circuit of a counter-flow heat exchanger. Hot nitrogen gas is flowing through a pipe, colder nitrogen is flowing counter to the hot stream in the annulus pipe and heat transfer occurs through metal tubes. The problem considered is to calculate flowrates and temperature distributions in both streams. GFSSP has a unique data structure, as shown in Figure 2, that allows constructing all possible arrangements of a flow network with no limit on the number of elements. The elements of a flow network are boundary nodes where pressure and temperature are specified, internal nodes where pressure and temperature are calculated, and branches where flowrates are calculated. For conjugate heat transfer problems, there are three additional elements: solid node, ambient node, and conductor. The solid and fluid nodes are connected with solid-fluid conductors. GFSSP solves the conservation equations of mass and energy, and equation of state in internal nodes to calculate pressure, temperature and resident mass. The momentum conservation equation is solved in branches to calculate flowrate. It also solves for energy conservation equations to calculate temperatures of solid nodes. The equations are coupled and nonlinear; therefore, they are solved by an iterative numerical scheme. GFSSP employs a unique numerical scheme known as simultaneous adjustment with successive substitution (SASS), which is a combination of Newton-Raphson and successive substitution methods. The mass and momentum conservation equations and the equation of state are solved by the Newton-Raphson method while the conservation of energy and species are solved by the successive substitution method. GFSSP is linked with two thermodynamic property programs, GASP2 and WASP3 and GASPAK4, that provide thermodynamic and thermophysical properties of selected fluids. Both programs cover a range of pressure and temperature that allows fluid properties to be evaluated for liquid, liquid-vapor (saturation), and vapor region. GASP and WASP provide properties of 12 fluids. GASPAK includes a library of 36 fluids. GFSSP has three major parts. The first part is the graphical user interface (GUI), visual thermofluid analyzer of systems and components (VTASC). VTASC allows users to create a flow circuit by a 'point and click' paradigm. It creates the GFSSP input file after the completion of the model building process. GFSSP's GUI provides the users a platform to build and run their models. It also allows post-processing of results. The network flow circuit is first built using three basic elements: boundary node, internal node, and branch.

Majumdar, A. K.↗

Organic matter and soil structure in the Everglades Agricultural Area

This publication pertains to management of organic soils (Histosols) in the Everglades Agricultural Area (EAA). These former wetland soils are a major resource for efficient agricultural production and are important globally for their high organic matter content. Recognition of global warming has led to considerable interest in soils as a repository for carbon. Soils rich in organic matter essentially sequester or retain carbon in the profile and can contribute directly to keeping that sequestered carbon from entering the atmosphere. Identification and utilization of management practices that minimize the loss of carbon from organic soils to the atmosphere can minimize effects on global warming and increase the longevity of subsiding Histosols for agricultural use. Understanding and predicting how these muck soils will respond to current and changing land uses will help to manage soil carbon. The objectives of this document are to: a. Discuss organic soil oxidation relative to storing or releasing carbon and nitrogen b. Evaluate effects of cultivation (compare structure for sugarcane vs. uncultivated soil) Based upon the findings from the land-use comparison (sugarcane or uncultivated), organic carbon was higher with cultivation in the lower depths. There is considerable potential for minimum tillage and residue management to further enhance carbon sequestration in the sugarcane system. Carbon sequestration is improved and soil subsidence is slowed with sugarcane production, and both of these are positive outcomes. Taking action to increase or maintain carbon sequestration appears to be appropriate but may introduce some risk to farming operations. Additional management methods are needed to reduce this risk. For both the longevity of these organic soils and from a global perspective, slowing subsidence through BMP implementation makes sense. Since these BMPs also have considerable societal benefit, it remains to be seen if society will help to offset a part or all of the additional risk through some form of cost-sharing program or carbon credits trading. In general, the subsidence throughout the EAA has been slowed because of higher water table management and implementation of other selected BMPs. In addition, the comparison of soil with different land uses shows that the humification rate, conversion of organic matter from peat to humus, has changed. Another likely factor is a relative increase in the mineral content of soil as the organic constituents are lost through subsidence.

54 ENVIRONMENTAL SCIENCES↗