Search NASA⌕ Search

SEARCH · Search NASA

Results for “Validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

A Possible Tool for Checking Errors in the INAA Results, Based on Neutron Data and Method Validation

This work presents preliminary results of a new type of possible application in the INAA experiments of elemental analysis, useful to check errors occurred during investigation of unknown samples; it relies on the INAA method validation experiments and accuracy of the neutron data from the literature. The paper comprises 2 sections, the first one presents--in short--the steps of the experimental tests carried out for INAA method validation and for establishing the 'ACTIVA-N' laboratory performance, which is-at the same time-an illustration of the laboratory evolution on the way to get performance. Section 2 presents our recent INAA results on CRMs, of which interpretation opens discussions about the usefulness of using a tool for checking possible errors, different from the usual statistical procedures. The questionable aspects and the requirements to develop a practical checking tool are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental validation of a diagnostic technique for tuning the fourth shock timing on National Ignition Facility

Capsule implosions on the National Ignition Facility (NIF) [Lindl et al., Phys. Plasmas 11, 339 (2004)] will be driven with a carefully tailored sequence of four shock waves that must be timed to very high precision in order to keep the fuel on a low adiabat. The Hohlraum conditions present during the first three shocks allow for a very accurate and direct diagnosis of the strength and timing of each individual shock by velocity interferometry. Experimental validation of this diagnostic technique on the OMEGA Laser Facility [Boehly et al., Opt. Commun. 133, 495 (1997)] has been reported in [Boehly et al., Phys. Plasmas 16, 056302 (2009)]. The Hohlraum environment present during the launch and propagation of the final shock, by contrast, is much more severe and will not permit diagnosis by the same technique. A new, closely related technique has been proposed for measuring and tuning the strength and timing of the fourth shock. Experiments to test this technique under NIF-relevant conditions have also been performed on OMEGA. The result of these experiments and a comparison to numerical simulations is presented, validating this concept.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Commissioning and Validation of the First Monte Carlo Based Dose Calculation Algorithm Commercial Treatment Planning System in Mexico

This work presents the beam data commissioning and dose calculation validation of the first Monte Carlo (MC) based treatment planning system (TPS) installed in Mexico. According to the manufacturer specifications, the beam data commissioning needed for this model includes: several in-air and water profiles, depth dose curves, head-scatter factors and output factors (6x6, 12x12, 18x18, 24x24, 42x42, 60x60, 80x80 and 100x100 mm{sup 2}). Radiographic and radiochromic films, diode and ionization chambers were used for data acquisition. MC dose calculations in a water phantom were used to validate the MC simulations using comparisons with measured data. Gamma index criteria 2%/2 mm were used to evaluate the accuracy of MC calculations. MC calculated data show an excellent agreement for field sizes from 18x18 to 100x100 mm{sup 2}. Gamma analysis shows that in average, 95% and 100% of the data passes the gamma index criteria for these fields, respectively. For smaller fields (12x12 and 6x6 mm{sup 2}) only 92% of the data meet the criteria. Total scatter factors show a good agreement (<2.6%) between MC calculated and measured data, except for the smaller fields (12x12 and 6x6 mm{sup 2}) that show a error of 4.7%. MC dose calculations are accurate and precise for clinical treatment planning up to a field size of 18x18 mm{sup 2}. Special care must be taken for smaller fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgrade and validation on plasma of the Tore Supra CW LHCD generator

A one year-long major upgrade of the 3.7 GHz Lower Hybrid Current Drive (LHCD) generator for the Tore Supra (TS) tokamak has been performed. It consisted in installing a first series of eight Thales Electron Devices (TED) 700 kW CW klystrons, new CW components and auxiliaries, and in modifying the transmitter control and protection software. Modifications and calibration of the sensors and the RF subsystems were completed as well. Finally, the RF power available in the generator has been increased by 35% and the pulse duration could reach 1000 s. A complete validation and optimization of the klystrons have been performed in 2010 on matched load before the generator could enter into operation. The eight klystrons connected with the Full Active Multijunction (FAM) antenna delivered 3.5 MW/50s in December 2010. The upgrade of the generator and the steps to validate the modifications are described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Civa 10 RX module: Preliminary validation in a nuclear context

The French Institute for Radioprotection and Nuclear Safety (IRSN) in partnership with CEA, has started in 2009 a program over several years for the validation of CIVA RX module. The aim of this paper is to present preliminary results of CIVA RX tools validation. The study consists in a cross comparison between experimental and simulation results. These have been carried out on different objects (step wedge, dissimilar metal weld mock up, IQI, notches) with different sources (Co{sup 60} and 450 kV X-ray tube) and radiographic film. Simulation and experimental data are compared in term of optical density, IQI perceptivity and flaws detectability. This study shows a good agreement between experiment and simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ESA DUE GlobVapour water vapor products: Validation

The main objective of the European Space Agency (ESA) Data User Element (DUE) GlobVapour project was the development of multi-annual global water vapor data sets. Since water vapour is a key climate variable it is important to have a good understanding of its behavior in the climate system. The ESA DUE GlobVapour project provides water vapor data, including error estimates, based on carefully calibrated and inter-calibrated satellite radiances in response to user requirements for long time series satellite observations. ESA DUE GlobVapour total columnar water vapor (TCWV) products derived from GOME/SCIA/GOME-2 (1996-2008) and SSM/I+MERIS (2003-2008) have been validated for the mentioned period, using satellite-based (AIRS, ATOVS) and ground-based measurements (radiosondes and microwave radiometer). The validation results are discussed in the following. The technical specifications on bias (1 kg/m{sup 2} for SSMI+MERIS and 2 kg/m{sup 2} for GOME/SCIA/GOME-2) are generally met. For more information, documents and data download follow the link: www.globvapour.info.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser Doppler vibrometry for assessment of arteriosclerosis: A first step towards validation

It has been shown that in cardiovascular risk management, stiffness of large arteries has a very good predictive value for cardiovascular disease and mortality. This parameter can be estimated from the pulse wave velocity (PWV) measured between the common carotid artery (CCA) in the neck and femoral artery (FA) in the groin. However PWV can also be measured locally in the CCA, using non-invasive methods such as ultrasound (US) or laser Doppler vibrometry (LDV). Potential of the latter approach was already explored in previous research, and in this work a first step towards clinical validation is made. 50 hypertension II/III patients aged between 30 and 65 participate in the study. Patients were asked to remain sober for 4 hours prior to the measurements. The trajectory of the CCA in the neck was determined by a trained clinician guided by an US probe. 3 laser Doppler vibrometer (LDV) systems were aimed along the CCA. PWV was then calculated from the distance between beams and the time-shift between waveforms. Immediately after LDV measurements, PWV was measured with US. Additionally, carotid-femoral PWV was measured. As a validation, PWV results of the different techniques were compared with each other, and with medical background of the test subjects. Since data acquisition is still ongoing, data from only 20 patients will be discussed. No trends between measurement methods for PWV are apparent. However, a positive trend was detected between PWV as measured with LDV and blood pressure. More data, including additional experiments will be needed to verify this observation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-ray digital industrial radiography (DIR) for local liquid velocity (V{sub LL}) measurement in trickle bed reactors (TBRs): Validation of the technique

Local liquid velocity measurements in Trickle Bed Reactors (TBRs) are one of the essential components in its hydrodynamic studies. These measurements are used to effectively determine a reactor's operating condition. This study was conducted to validate a newly developed technique that combines Digital Industrial Radiography (DIR) with Particle Tracking Velocimetry (PTV) to measure the Local Liquid Velocity (V{sub LL}) inside TBRs. Three millimeter-sized Expanded Polystyrene (EPS) beads were used as packing material. Three validation procedures were designed to test the newly developed technique. All procedures and statistical approaches provided strong evidence that the technique can be used to measure the V{sub LL} within TBRs.

42 ENGINEERING↗

Ultrasonic linear array validation via concrete test blocks

Oak Ridge National Laboratory (ORNL) comparatively evaluated the ability of a number of NDE techniques to generate an image of the volume of 6.5′ X 5.0′ X 10″ concrete specimens fabricated at the Florida Department of Transportation (FDOT) NDE Validation Facility in Gainesville, Florida. These test blocks were fabricated to test the ability of various NDE methods to characterize various placements and sizes of rebar as well as simulated cracking and non-consolidation flaws. The first version of the ultrasonic linear array device, MIRA [version 1], was one of 7 different NDE equipment used to characterize the specimens. This paper deals with the ability of this equipment to determine subsurface characterizations such as reinforcing steel relative size, concrete thickness, irregularities, and inclusions using Kirchhoff-based migration techniques. The ability of individual synthetic aperture focusing technique (SAFT) B-scan cross sections resulting from self-contained scans are compared with various processing, analysis, and interpretation methods using the various features fabricated in the specimens for validation. The performance is detailed, especially with respect to the limitations and implications for evaluation of a thicker, more heavily reinforced concrete structures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Prototyping and validating requirements of radiation and nuclear emergency plan simulator

Organizational incapability in developing unrealistic, impractical, inadequate and ambiguous mechanisms of radiological and nuclear emergency preparedness and response plan (EPR) causing emergency plan disorder and severe disasters. These situations resulting from 65.6% of poor definition and unidentified roles and duties of the disaster coordinator. Those unexpected conditions brought huge aftermath to the first responders, operators, workers, patients and community at large. Hence, in this report, we discuss prototyping and validating of Malaysia radiation and nuclear emergency preparedness and response plan simulation model (EPRM). A prototyping technique was required to formalize the simulation model requirements. Prototyping as systems requirements validation was carried on to endorse the correctness of the model itself against the stakeholder’s intensions in resolving those organizational incapability. We have made assumptions for the proposed emergency preparedness and response model (EPRM) through the simulation software. Those assumptions provided a twofold of expected mechanisms, planning and handling of the respective emergency plan as well as in bringing off the hazard involved. This model called RANEPF (Radiation and Nuclear Emergency Planning Framework) simulator demonstrated the training emergency response perquisites rather than the intervention principles alone. The demonstrations involved the determination of the casualties’ absorbed dose range screening and the coordination of the capacity planning of the expected trauma triage. Through user-centred design and sociotechnical approach, RANEPF simulator was strategized and simplified, though certainly it is equally complex.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Validations of calibration-free measurements of electron temperature using double-pass Thomson scattering diagnostics from theoretical and experimental aspects

This paper evaluates the accuracy of electron temperature measurements and relative transmissivities of double-pass Thomson scattering diagnostics. The electron temperature (T{sub e}) is obtained from the ratio of signals from a double-pass scattering system, then relative transmissivities are calculated from the measured T{sub e} and intensity of the signals. How accurate the values are depends on the electron temperature (T{sub e}) and scattering angle (θ), and therefore the accuracy of the values was evaluated experimentally using the Large Helical Device (LHD) and the Tokyo spherical tokamak-2 (TST-2). Analyzing the data from the TST-2 indicates that a high T{sub e} and a large scattering angle (θ) yield accurate values. Indeed, the errors for scattering angle θ = 135° are approximately half of those for θ = 115°. The method of determining the T{sub e} in a wide T{sub e} range spanning over two orders of magnitude (0.01–1.5 keV) was validated using the experimental results of the LHD and TST-2. A simple method to provide relative transmissivities, which include inputs from collection optics, vacuum window, optical fibers, and polychromators, is also presented. The relative errors were less than approximately 10%. Numerical simulations also indicate that the T{sub e} measurements are valid under harsh radiation conditions. This method to obtain T{sub e} can be considered for the design of Thomson scattering systems where there is high-performance plasma that generates harsh radiation environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validating Intra-Plate Power Distributions in the Advanced Test Reactor

We report that the neutronics software, HELIOS, was validated in 2015 for performing core reload design and safety analysis of the Advanced Test Reactor. However, when HELIOS was benchmarked against historic fission-wire measurements (i.e., zero-power full-core measurements) a statistically resolved calculation-to-measurement bias was discovered. The azimuthal power along each fuel plate computed by HELIOS has consistently shown to under-predict measurements made by fission-wires in historic zero-power tests near the fuel element side-plates. It was hypothesized during the HELIOS software validation work, that this bias is attributable to local moderation in coolant vents in the side-plates axially just above and below the fission-wires on the fuel-plate edges. This work used detailed MCNP and MC21 models of the side-plate vents to test this hypothesis. By comparing the average azimuthal biases between HELIOS, and 2D and 3D MCNP models, and a 3D MC21 model, it was found that the HELIOS azimuthal bias is not due to the measurement.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Implementation of a Drift Flux Model into SAM with Development of a Verification and Validation Test Suite for Modeling of Noncondensable Gas Mixtures

The advanced thermal-hydraulic system code, System Analysis Module (SAM), was originally developed for the modeling of single-phase flow in advanced reactors. It has since been expanded to include a four-equation drift flux model for the modeling of two-phase flows containing a noncondensable gas. The model was expanded to support the modeling of molten salt reactor (MSR) designs in which the fuel is directly dissolved in the circulating coolant. These designs have shown that circulating gas bubbles can play an important role in the management of fission products and the operational behavior of the reactor. A drift flux model was implemented to more accurately capture the localized behavior of the void in the core and its impact on the mass transfer of fission products. A thorough assessment of the new model was performed by developing a verification and validation test suite. Verification problems were designed to test all major terms in the new governing equations. The new model converged to the correct solution at the expected order of accuracy for all verification cases. The validation cases included a wide range of flow and void conditions in different pipe geometries. Although higher void experiments show a slight underprediction of void by the drift flux model, experiments that aim to reproduce Molten Salt Reactor Experiment (MSRE) experimental conditions show good agreement with the model. The gas transport model was activated for a SAM model of the MSRE to demonstrate that it can be used in a more complex model. Finally, this gas transport model will be used along with an interfacial area transport equation being implemented in SAM for the prediction of mass transport behavior in MSR conditions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of HELIOS/BIPR/PARCS/MCNP6 Computation Route for WWER RPV Neutron Fluence Analysis and Validation Against Ex-Vessel Detector Measurement Data

Here, a computational route was developed for precise calculation of fast neutron fluence on a WWER-type reactor pressure vessel (RPV). The method is based on the transfer of neutronics data from HELIOS-2 lattice calculations and nodal diffusion neutronics data (power, density, and temperature) from BIPR7.1 and PARCS 3.36/PATHS core calculations into a three-dimensional (pinwise axially distributed) fixed neutron source for modeling of transport of fast neutrons from the reactor core to the outer surface of the RPV using MCNP6.2. Validation of the proposed computational method was carried out based on comparative analysis of MCNP6.2-predicted and neutron dosimetry–measured reaction rates [ 54 Fe(n,p) 54 Мn, 93 Nb(n,n') 93 mNb, and 58 Ni(n,р) 58 Со] on the outer surface of the Armenian Nuclear Power Plant (ANPP) Unit 2 RPV. Validation revealed that the MCNP6.2-predicted fast neutron fluence results are very sensitive to the ENDF-B neutron data. Particularly, MCNP6.2 with ENDF/B-VIII.0 significantly underpredicts (20% to 30%) fast neutron fluence while using ENDF/B-VII.1 data overpredicts it. Adding revised beta-released evaluations of 54 Fe, 56 Fe, 57 Fe, and 16 O from the International Nuclear Data Evaluation Network (INDEN) to ENDF/B-VIII.0 allows one to obtain reasonable agreement with measurement results for all types of measured reaction rates.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Verification and validation of detonation-shock-dynamics relations for explosives described by general equation of state and chemical reaction models

Detonation shock dynamics is a powerful method to model the behaviour of High Explosives (HE). However in order to use this method, the underlying relationship between the local radius of curvature and the detonation speed must be known. Previous work has developed methods to calculate this effect using simple, single-step Arrhenius and polytropic gas, models for the chemical reaction and the equation of state, respectively. In recent years, more complex models for both reaction rates and equations of state have been developed which show better agreement with experimental data than these simple models, especially when considering condensed phase explosives.. This work presents the governing equations for solving these problems in a way that is generalised to use arbitrary equations of state as well as reaction models which may have more than a single step and multiple product species. This implementation is verified against exact solutions, demonstrating that the equations were implemented properly. The verified algorithm is then validated against experimental data and high fidelity simulations, showing that it is able to make accurate predictions in a regime where the underlying assumptions of the governing equations are valid. Importantly, this approach has many applications: from creating equivalent detonation shock dynamics models for existing reactive burn calibrations for HE; to developing new functional forms and calibrations of reactive burn models for condensed phase high explosives.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

VALIDATION OF OBSERVATIONS OBTAINED WITH A LIQUID MIRROR TELESCOPE BY COMPARISON WITH SLOAN DIGITAL SKY SURVEY OBSERVATIONS

The results of a search for peculiar astronomical objects using very low resolution spectra obtained with the NASA Orbital Debris Observatory (NODO) 3 m diameter liquid mirror telescope (LMT) are compared with results of spectra obtained with the Sloan Digital Sky Survey (SDSS). The main purpose of this comparison is to verify whether observations taken with this novel type of telescope are reliable. This comparison is important because LMTs are an inexpensive novel type of telescope that is very useful for astronomical surveys, particularly surveys in the time domain, and validation of the data taken with an LMT by comparison with data from a classical telescope will validate their reliability. We start from a published data analysis that classified as peculiar only 206 of the 18,000 astronomical objects observed with the NODO LMT. A total of 29 of these 206 objects were found in the SDSS. The reliability of the NODO data can be seen through the results of the detailed analysis that, in practice, incorrectly identified less than 0.3% of the 18,000 spectra as peculiar objects, most likely because they are variable stars. We conclude that the LMT gave reliable observations, comparable to those that would have been obtained with a telescope using a glass mirror.

79 ASTRONOMY AND ASTROPHYSICS↗

Validation of Kepler's multiple planet candidates. III. Light curve analysis and announcement of hundreds of new multi-planet systems

The Kepler mission has discovered more than 2500 exoplanet candidates in the first two years of spacecraft data, with approximately 40% of those in candidate multi-planet systems. The high rate of multiplicity combined with the low rate of identified false positives indicates that the multiplanet systems contain very few false positive signals due to other systems not gravitationally bound to the target star. False positives in the multi-planet systems are identified and removed, leaving behind a residual population of candidate multi-planet transiting systems expected to have a false positive rate less than 1%. We present a sample of 340 planetary systems that contain 851 planets that are validated to substantially better than the 99% confidence level; the vast majority of these have not been previously verified as planets. We expect ∼two unidentified false positives making our sample of planet very reliable. We present fundamental planetary properties of our sample based on a comprehensive analysis of Kepler light curves, ground-based spectroscopy, and high-resolution imaging. Since we do not require spectroscopy or high-resolution imaging for validation, some of our derived parameters for a planetary system may be systematically incorrect due to dilution from light due to additional stars in the photometric aperture. Nonetheless, our result nearly doubles the number verified exoplanets.

79 ASTRONOMY AND ASTROPHYSICS↗

VALIDATION OF 12 SMALL KEPLER TRANSITING PLANETS IN THE HABITABLE ZONE

We present an investigation of 12 candidate transiting planets from Kepler with orbital periods ranging from 34 to 207 days, selected from initial indications that they are small and potentially in the habitable zone (HZ) of their parent stars. Few of these objects are known. The expected Doppler signals are too small to confirm them by demonstrating that their masses are in the planetary regime. Here we verify their planetary nature by validating them statistically using the BLENDER technique, which simulates large numbers of false positives and compares the resulting light curves with the Kepler photometry. This analysis was supplemented with new follow-up observations (high-resolution optical and near-infrared spectroscopy, adaptive optics imaging, and speckle interferometry), as well as an analysis of the flux centroids. For 11 of them (KOI-0571.05, 1422.04, 1422.05, 2529.02, 3255.01, 3284.01, 4005.01, 4087.01, 4622.01, 4742.01, and 4745.01) we show that the likelihood they are true planets is far greater than that of a false positive, to a confidence level of 99.73% (3σ) or higher. For KOI-4427.01 the confidence level is about 99.2% (2.6σ). With our accurate characterization of the GKM host stars, the derived planetary radii range from 1.1 to 2.7 R {sub ⊕}. All 12 objects are confirmed to be in the HZ, and nine are small enough to be rocky. Excluding three of them that have been previously validated by others, our study doubles the number of known rocky planets in the HZ. KOI-3284.01 (Kepler-438b) and KOI-4742.01 (Kepler-442b) are the planets most similar to the Earth discovered to date when considering their size and incident flux jointly.

79 ASTRONOMY AND ASTROPHYSICS↗