Search NASA⌕ Search

SEARCH · Search NASA

Results for “adaptive methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Certainty Equivalence M-MRAC for Systems with Unmatched Uncertainties

The paper presents a certainty equivalence state feedback indirect adaptive control design method for the systems of any relative degree with unmatched uncertainties. The approach is based on the parameter identification (estimation) model, which is completely separated from the control design and is capable of producing parameter estimates as fast as the computing power allows without generating high frequency oscillations. It is shown that the system's input and output tracking errors can be systematically decreased by the proper choice of the design parameters.

Unmatched uncertainties↗

Combining computational modeling and experimental library screening to affinity-mature VEEV-neutralizing antibody F5

Engineered monoclonal antibodies have proven to be highly effective therapeutics in recent viral outbreaks. However, despite technical advancements, an ability to rapidly adapt or increase antibody affinity and by extension, therapeutic efficacy, has yet to be fully realized. We endeavored to stand-up such a pipeline using molecular modeling combined with experimental library screening to increase the affinity of F5, a monoclonal antibody with potent neutralizing activity against Venezuelan Equine Encephalitis Virus (VEEV), to recombinant VEEV (IAB) E1E2 antigen. We modeled the F5/E1E2 binding interface and generated predictions for mutations to improve binding using a Rosetta-based approach and dTERMen, an informatics approach. The modeling was complicated by the fact that a high-resolution structure of F5 is not available and the H3 loop of F5 exceeds the length for which current modeling approaches can determine a unique structure. A subset of the predicted mutations from both methods were incorporated into a phage display library of scFvs. This library and a library generated by error-prone PCR were screened for binding affinity to the recombinant antigen. Results from the screens identified favorable mutations which were incorporated into 12 human-IgG1 variants. The best variant, containing eight mutations, improved KD from 0.63 nM (parental) to 0.01 nM. While this did not improve neutralization or therapeutic potency of F5 against IAB, it did increase cross-reactivity to other closely related VEEV epizootic and enzootic strains, demonstrating the potential of this method to rapidly adapt existing therapeutics to emerging viral strains.

affinity-maturation↗

Multielectron effects on the orientation dependence and photoelectron angular distribution of multiphoton ionization of CO{sub 2} in strong laser fields

We perform an ab initio study of multiphoton ionization (MPI) of carbon dioxide in intense linearly polarized laser pulses with arbitrary molecular orientation by means of a time-dependent density-functional theory (TDDFT) with proper long-range potential. We develop a time-dependent Voronoi-cell finite difference method with highly adaptive molecular grids for accurate solution of the TDDFT equations. Our results demonstrate that the orientation dependence of MPI is determined by multiple orbital contributions and that the electron correlation effects are significant. The maximum peak of MPI is predicted to be at 40 deg. in good agreement with recent experimental data. Photoelectron angular distribution reveals the delicate relation between the orientation dependence and the molecular orbital symmetry.

74 ATOMIC AND MOLECULAR PHYSICS↗

Scheduling Mission Reconfiguration for an Interferometry Synthetic Aperture Radar Using Deep Reinforcement Learning

This paper presents a method to intelligently adapt the baseline of a synthetic aperture radar based on Deep Rein- forcement Learning to help create plans for missions that use formation flight for Earth observation purposes. The main contribution of this paper is the initial results we have found from applying the tool to a toy mission: measuring the ver- tical structure of forests by using a synthetic aperture radar mounted on a formation of 7 satellites orbiting the Earth in a Sun Synchronous Orbit. We have found that with a reward function based on expected science return over time and fuel usage, the Deep Reinforcement Learning planner is able to create plans with positive scientific returns while minimizing fuel usage. We also find that fuel usage and collision avoid- ance planning is better done with traditional methods, as Deep Reinforcement Learning does not converge to optimal solutions.

Viros-i-Martin, Antoni↗

Deep Reinforcement Learning From Demonstrations to Assist Service Restoration in Islanded Microgrids

Microgrids can be operated in island mode during utility grid outages to support service restoration and improve system resilience. To schedule and dispatch distributed energy resources (DERs) in an islanded microgrid, conventional model-based methods rely on accurate distribution network models and lack generalization and adaptability. Data-driven methods are promising for DER coordination but face practical challenges such as potential hazards to microgrids during online training and insufficient online training opportunities due to low outage rates. This paper presents a novel two-stage learning framework that builds on the deep deterministic policy gradient from demonstrations to identify an optimal restoration strategy. At the pre-training stage, imitation learning is applied to equip the control agent with expert experiences to guarantee acceptable initial performance. At the online training stage, action clipping, reward shaping, and expert demonstrations are leveraged to ensure safe exploration while accelerating the training process. In conclusion, the proposed method is illustrated using the IEEE 123-node system and compared with a representative model-based method and the standard deep deterministic policy gradient method to prove solution accuracy and demonstrate increased computational efficiency.

Du, Yan↗

Automated planning of breast radiotherapy using cone beam CT imaging

Purpose: Develop and clinically validate a methodology for using cone beam computed tomography (CBCT) imaging in an automated treatment planning framework for breast IMRT. Methods: A technique for intensity correction of CBCT images was developed and evaluated. The technique is based on histogram matching of CBCT image sets, using information from “similar” planning CT image sets from a database of paired CBCT and CT image sets (n = 38). Automated treatment plans were generated for a testing subset (n = 15) on the planning CT and the corrected CBCT. The plans generated on the corrected CBCT were compared to the CT-based plans in terms of beam parameters, dosimetric indices, and dose distributions. Results: The corrected CBCT images showed considerable similarity to their corresponding planning CTs (average mutual information 1.0±0.1, average sum of absolute differences 185 ± 38). The automated CBCT-based plans were clinically acceptable, as well as equivalent to the CT-based plans with average gantry angle difference of 0.99°±1.1°, target volume overlap index (Dice) of 0.89±0.04 although with slightly higher maximum target doses (4482±90 vs 4560±84, P < 0.05). Gamma index analysis (3%, 3 mm) showed that the CBCT-based plans had the same dose distribution as plans calculated with the same beams on the registered planning CTs (average gamma index 0.12±0.04, gamma <1 in 99.4%±0.3%). Conclusions: The proposed method demonstrates the potential for a clinically feasible and efficient online adaptive breast IMRT planning method based on CBCT imaging, integrating automation.

60 APPLIED LIFE SCIENCES↗

Full-Scale Flight Research Testbeds: Adaptive and Intelligent Control

This viewgraph presentation describes the adaptive and intelligent control methods used for aircraft survival. The contents include: 1) Motivation for Adaptive Control; 2) Integrated Resilient Aircraft Control Project; 3) Full-scale Flight Assets in Use for IRAC; 4) NASA NF-15B Tail Number 837; 5) Gen II Direct Adaptive Control Architecture; 6) Limited Authority System; and 7) 837 Flight Experiments. A simulated destabilization failure analysis along with experience and lessons learned are also presented.

Pahle, Joe W.↗

Adaptive clipping‐and‐redistribution algorithms for bounded and conservative high‐order interpolations applied to discontinuous and reactive flows

Abstract A new adaptive clipping‐and‐redistribution method is presented which provides bounds‐preservation for multidimensional interpolation in the context of high‐order finite‐volume discretizations with adaptive mesh refinement (AMR). The underlying finite‐volume method (FVM) for the computational fluid dynamics applications is fourth‐order accurate for smooth solutions and utilizes AMR for computational efficiency in solving multiscale problems involving turbulence and combustion. High‐order interpolation between different AMR levels is required. However, this operation often leads to numerical issues because combustion species must have physical bounds preserved. The present study overcomes two major challenges in the development of the high‐order interpolation method. First, the method needs to be bound‐preserving near extrema or discontinuities to prevent the emergence of unphysical oscillations while maintaining fourth‐order accuracy in smooth flows. Second, the method needs to satisfy the conservation requirement in multiple dimensions, particularly in the context of curvilinear coordinate transformations. Additionally, the method is designed to be localized and computationally inexpensive. The new interpolation scheme is demonstrated by solving reacting flows, which are extremely sensitive to unphysical overshoots in conserved quantities. The test problems are shock‐induced ‐ combustion and a ‐air flame in a practical bluff‐body combustor. Results show the method prevents new extrema near discontinuities while maintaining high‐order accuracy in smooth regions. In particular, the method is extremely beneficial for combustion with stiff chemistry. With the proposed new method, even if flame fronts cross AMR interfaces or new grids are created in the vicinity of the flame, solution stability is retained.

97 MATHEMATICS AND COMPUTING↗

Optimal control model of technology transition.

This paper discusses the use of optimization software to solve an optimal control problem arising in the modeling of technology transition. We set up a series of increasingly complex models with such features as learning-by-doing, adjustment cost, and capital investment. The models are written in continuous time and then discretized by using different methods to transform them into large-scale nonlinear programs. We use a modeling language and numerical optimization methods to solve the optimization problem. Our results are consistent with findings in the literature and highlight the impact the discretization choice has on the solution and accuracy. The primary goal of this paper is to develop solution methods for use in policy work. To do this, we will need to expand the model to include realistic features such as additional technologies and capital conversion. Our modeling approach allows us to add new technologies with minimal effort. For example, Figure 5 presents the solution to the capital model that includes a third technology, say, nuclear fusion, that is emission free but even more expensive (A{sub 3} > A{sub n}). We observe that industry first transitions to the intermediate technology but eventually adopts the cleanest one. We note that our solutions have few areas of large curvature and are relatively smooth elsewhere. On such smooth segments, we can achieve adequate precision with relatively large periods, which means fewer variables and increased computation speed. But we still need a small step length during the transition period. Adaptive mesh refinement methods have been developed to automatically identify the areas where extra precision is needed. Betts (2001) describes how the computation time can be reduced by a factor of 2.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

SU-E-J-102: Performance Variations Among Clinically Available Deformable Image Registration Tools in Adaptive Radiotherapy: How Should We Evaluate and Interpret the Result?

Purpose: To evaluate the performance variations in commercial deformable image registration (DIR) tools for adaptive radiation therapy. Methods: Representative plans from three different anatomical sites, prostate, head-and-neck (HN) and cranial spinal irradiation (CSI) with L-spine boost, were included. Computerized deformed CT images were first generated using virtual DIR QA software (ImSimQA) for each case. The corresponding transformations served as the “reference”. Three commercial software packages MIMVista v5.5 and MIMMaestro v6.0, VelocityAI v2.6.2, and OnQ rts v2.1.15 were tested. The warped contours and doses were compared with the “reference” and among each other. Results: The performance in transferring contours was comparable among all three tools with an average DICE coefficient of 0.81 for all the organs. However, the performance of dose warping accuracy appeared to rely on the evaluation end points. Volume based DVH comparisons were not sensitive enough to illustrate all the detailed variations while isodose assessment on a slice-by-slice basis could be tedious. Point-based evaluation was over-sensitive by having up to 30% hot/cold-spot differences. If adapting the 3mm/3% gamma analysis into the evaluation of dose warping, all three algorithms presented a reasonable level of equivalency. One algorithm had over 10% of the voxels not meeting this criterion for the HN case while another showed disagreement for the CSI case. Conclusion: Overall, our results demonstrated that evaluation based only on the performance of contour transformation could not guarantee the accuracy in dose warping. However, the performance of dose warping accuracy relied on the evaluation methodologies. Nevertheless, as more DIR tools are available for clinical use, the performance could vary at certain degrees. A standard quality assurance criterion with clinical meaning should be established for DIR QA, similar to the gamma index concept, in the near future.

60 APPLIED LIFE SCIENCES↗

Correlated electron pseudopotentials for 3d-transition metals

A recently published correlated electron pseudopotentials (CEPPs) method has been adapted for application to the 3d-transition metals, and to include relativistic effects. New CEPPs are reported for the atoms Sc − Fe, constructed from atomic quantum chemical calculations that include an accurate description of correlated electrons. Dissociation energies, molecular geometries, and zero-point vibrational energies of small molecules are compared with all electron results, with all quantities evaluated using coupled cluster singles doubles and triples calculations. The CEPPs give better results in the correlated-electron calculations than Hartree-Fock-based pseudopotentials available in the literature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Towards and FVE-FAC Method for Determining Thermocapillary Effects on Weld Pool Shape

Several practical materials processes, e.g., welding, float-zone purification, and Czochralski crystal growth, involve a pool of molten metal with a free surface, with strong temperature gradients along the surface. In some cases, the resulting thermocapillary flow is vigorous enough to convect heat toward the edges of the pool, increasing the driving force in a sort of positive feedback. In this work we examine this mechanism and its effect on the solid-liquid interface through a model problem: a half space of pure substance with concentrated axisymmetric surface heating, where surface tension is strong enough to keep the liquid free surface flat. The numerical method proposed for this problem utilizes a finite volume element (FVE) discretization in cylindrical coordinates. Because of the axisymmetric nature of the model problem, the control volumes used are torroidal prisms, formed by taking a polygonal cross-section in the (r, z) plane and sweeping it completely around the z-axis. Conservation of energy (in the solid), and conservation of energy, momentum, and mass (in the liquid) are enforced globally by integrating these quantities and enforcing conservation over each control volume. Judicious application of the Divergence Theorem and Stokes' Theorem, combined with a Crank-Nicolson time-stepping scheme leads to an implicit algebraic system to be solved at each time step. It is known that near the boundary of the pool, that is, near the solid-liquid interface, the full conduction-convection solution will require extremely fine length scales to resolve the physical behavior of the system. Furthermore, this boundary moves as a function of time. Accordingly, we develop the foundation of an adaptive refinement scheme based on the principles of Fast Adaptive Composite Grid methods (FAC). Implementation of the method and numerical results will appear in a later report.

Canright, David↗

Combined Borehole Seismic and Electromagnetic Inversion For High-Resolution Petrophysical Assessment Of Hydocarbon Reservoirs

This report summarizes the work performed between January 2005 and December 2007, under DOE research contract DE-FC26-04NT15507. The project is was performed by the Center for Petroleum and Geosystems Engineering of The University of Texas at Austin and Lawrence Berkeley National Laboratory under the auspices of the National Energy Technology Office (NETL) and the Strategic Center for Natural Gas and Oil (SCNGO). During the three-year project, we developed new methods to combine borehole sonic and electromagnetic (EM) measurements for the improved assessment of elastic and petrophysical properties of rock formations penetrated by a well. Sonic measurements consisted of full waveform acoustic amplitudes acquired with monopole and dipole sources, whereas EM measurements consisted of frequency-domain voltages acquired with multi-coil induction systems. The combination of sonic and EM measurements permitted the joint estimation of elastic and petrophysical properties in the presence of mud-filtrate invasion. It was conclusively shown that the combined interpretation of sonic and EM measurements reduced non-uniqueness in the estimation of elastic and petrophysical properties and improved the spatial resolution of the estimations compared to estimations yielded separately from the two types of measurements. Moreover, this approach enabled the assessment of dynamic petrophysical properties such as permeability, as it incorporated the physics of mud-filtrate invasion in the interpretation of the measurements. The first part of the project considered the development of fast and reliable numerical algorithms to simulate borehole sonic waveforms in 2D, 3D, and radial 1D media. Such algorithms were subsequently used in the quantitative estimation of elastic properties jointly from borehole sonic and EM measurements. In the second part of the project we developed a new algorithm to estimate water saturation, porosity, and dry-rock elastic moduli jointly from borehole sonic and EM measurements. This algorithm assumed radial 1D variations of fluid saturation due to mud-filtrate invasion. Subsequently, we adapted the estimation method to interpret borehole field measurements acquired in both a shaly-sand sedimentary sequence and a tight-gas sandstone formation. In the two cases, we simulated the process of mud-filtrate invasion and concomitantly honored sonic and EM measurements. We produced reliable estimates of permeability and dry-rock moduli that were successfully validated with rock-core measurements. Finally, we introduced a new stochastic inversion procedure to estimate elastic, electrical, and petrophysical properties of layered media jointly from waveform sonic and frequency-domain EM measurements. The procedure was based on Bayesian statistical inversion and delivered estimates of uncertainty under various forms of a-priori information about the unknown properties. Tests on realistic synthetic models confirmed the reliability of this procedure to estimate elastic and petrophysical properties jointly from sonic and EM measurements. Several extended abstracts and conference presentations stemmed from this project, including 2 SEG extended abstracts, 1 SPE extended abstract, and 2 SPWLA extended abstracts. Some of these extended abstracts have been submitted for publication in peer-reviewed journals.

02 PETROLEUM↗

Proton dose calculation on scatter-corrected CBCT image: Feasibility study for adaptive proton therapy

Purpose: To demonstrate the feasibility of proton dose calculation on scatter-corrected cone-beam computed tomographic (CBCT) images for the purpose of adaptive proton therapy. Methods: CBCT projection images were acquired from anthropomorphic phantoms and a prostate patient using an on-board imaging system of an Elekta infinity linear accelerator. Two previously introduced techniques were used to correct the scattered x-rays in the raw projection images: uniform scatter correction (CBCT{sub us}) and a priori CT-based scatter correction (CBCT{sub ap}). CBCT images were reconstructed using a standard FDK algorithm and GPU-based reconstruction toolkit. Soft tissue ROI-based HU shifting was used to improve HU accuracy of the uncorrected CBCT images and CBCT{sub us}, while no HU change was applied to the CBCT{sub ap}. The degree of equivalence of the corrected CBCT images with respect to the reference CT image (CT{sub ref}) was evaluated by using angular profiles of water equivalent path length (WEPL) and passively scattered proton treatment plans. The CBCT{sub ap} was further evaluated in more realistic scenarios such as rectal filling and weight loss to assess the effect of mismatched prior information on the corrected images. Results: The uncorrected CBCT and CBCT{sub us} images demonstrated substantial WEPL discrepancies (7.3 ± 5.3 mm and 11.1 ± 6.6 mm, respectively) with respect to the CT{sub ref}, while the CBCT{sub ap} images showed substantially reduced WEPL errors (2.4 ± 2.0 mm). Similarly, the CBCT{sub ap}-based treatment plans demonstrated a high pass rate (96.0% ± 2.5% in 2 mm/2% criteria) in a 3D gamma analysis. Conclusions: A priori CT-based scatter correction technique was shown to be promising for adaptive proton therapy, as it achieved equivalent proton dose distributions and water equivalent path lengths compared to those of a reference CT in a selection of anthropomorphic phantoms.

60 APPLIED LIFE SCIENCES↗

SU-F-BRF-01: A GPU Framework for Developing Interactive High-Resolution Patient-Specific Biomechanical Models

Purpose: To develop a GPU-based framework that can generate highresolution and patient-specific biomechanical models from a given simulation CT and contoured structures, optimized to run at interactive speeds, for addressing adaptive radiotherapy objectives. Method: A Massspring-damping (MSD) model was generated from a given simulation CT. The model's mass elements were generated for every voxel of anatomy, and positioned in a deformation space in the GPU memory. MSD connections were established between neighboring mass elements in a dense distribution. Contoured internal structures allowed control over elastic material properties of different tissues. Once the model was initialized in GPU memory, skeletal anatomy was actuated using rigid-body transformations, while soft tissues were governed by elastic corrective forces and constraints, which included tensile forces, shear forces, and spring damping forces. The model was validated by applying a known load to a soft tissue block and comparing the observed deformation to ground truth calculations from established elastic mechanics. Results: Our analyses showed that both local and global load experiments yielded results with a correlation coefficient R{sup 2} > 0.98 compared to ground truth. Models were generated for several anatomical regions. Head and neck models accurately simulated posture changes by rotating the skeletal anatomy in three dimensions. Pelvic models were developed for realistic deformations for changes in bladder volume. Thoracic models demonstrated breast deformation due to gravity when changing treatment position from supine to prone. The GPU framework performed at greater than 30 iterations per second for over 1 million mass elements with up to 26 MSD connections each. Conclusions: Realistic simulations of site-specific, complex posture and physiological changes were simulated at interactive speeds using patient data. Incorporating such a model with live patient tracking would facilitate real time assessment of variations of the actual anatomy and delivered dose for adaptive intervention and re-planning.

60 APPLIED LIFE SCIENCES↗

Monte Carlo calculation of the maximum therapeutic gain of tumor antivascular alpha therapy

Purpose: Metastatic melanoma lesions experienced marked regression after systemic targeted alpha therapy in a phase 1 clinical trial. This unexpected response was ascribed to tumor antivascular alpha therapy (TAVAT), in which effective tumor regression is achieved by killing endothelial cells (ECs) in tumor capillaries and, thus, depriving cancer cells of nutrition and oxygen. The purpose of this paper is to quantitatively analyze the therapeutic efficacy and safety of TAVAT by building up the testing Monte Carlo microdosimetric models. Methods: Geant4 was adapted to simulate the spatial nonuniform distribution of the alpha emitter {sup 213}Bi. The intraluminal model was designed to simulate the background dose to normal tissue capillary ECs from the nontargeted activity in the blood. The perivascular model calculates the EC dose from the activity bound to the perivascular cancer cells. The key parameters are the probability of an alpha particle traversing an EC nucleus, the energy deposition, the lineal energy transfer, and the specific energy. These results were then applied to interpret the clinical trial. Cell survival rate and therapeutic gain were determined. Results: The specific energy for an alpha particle hitting an EC nucleus in the intraluminal and perivascular models is 0.35 and 0.37 Gy, respectively. As the average probability of traversal in these models is 2.7% and 1.1%, the mean specific energy per decay drops to 1.0 cGy and 0.4 cGy, which demonstrates that the source distribution has a significant impact on the dose. Using the melanoma clinical trial activity of 25 mCi, the dose to tumor EC nucleus is found to be 3.2 Gy and to a normal capillary EC nucleus to be 1.8 cGy. These data give a maximum therapeutic gain of about 180 and validate the TAVAT concept. Conclusions: TAVAT can deliver a cytotoxic dose to tumor capillaries without being toxic to normal tissue capillaries.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adaptive Sampling-Based Bi-Fidelity Stochastic Trust Region Method for Stochastic Derivative-Free Optimization

Bi-fidelity stochastic optimization has gained increasing attention as an efficient approach to reduce computational costs by leveraging a low-fidelity (LF) model to optimize an expensive high-fidelity (HF) objective. In this paper, we propose ASTRO-BFDF, an adaptive sampling trust-region method specifically designed for unconstrained bi-fidelity stochastic derivative-free optimization problems. In ASTRO-BFDF, the LF function serves two purposes: (i) to identify better iterates for the HF function when the optimization process indicates a high correlation between them and (ii) to reduce the variance of the HF function estimates using bi-fidelity Monte Carlo (BFMC). The algorithm dynamically determines sample sizes while adaptively choosing between crude Monte Carlo and BFMC to balance the trade-off between optimization and sampling errors. We prove that the iterates generated by ASTRO-BFDF converge to a first-order stationary point almost surely. Additionally, we demonstrate the effectiveness of the proposed algorithm through numerical experiments on synthetic benchmarks and simulation optimization problems involving discrete event systems.

97 MATHEMATICS AND COMPUTING↗

SU-E-J-191: Automated Detection of Anatomic Changes in H'N Patients

Purpose: To develop a novel statistics-based method for automated detection of anatomical changes using cone-beam CT data. A method was developed that can provide a reliable and automated early warning system that enables a “just-in-time” adaptation of the treatment plan. Methods: Anatomical changes were evaluated by comparing the original treatment planning CT with daily CBCT images taken prior treatment delivery. The external body contour was computed on a given CT slice and compared against the corresponding contour on the daily CBCT. In contrast to threshold-based techniques, a statistical approach was employed to evaluate the difference between the contours using a given confidence level. The detection tool used the two-sample Kolmogorov-Smirnov test, which is a non-parametric technique that compares two samples drawn from arbitrary probability distributions. 11 H'N patients were retrospectively selected from a clinical imaging database with a total of 186 CBCT images. Six patients in the database were confirmed to have anatomic changes during the course of radiotherapy. Five of the H'N patients did not have significant changes. The KS test was applied to the contour data using a sliding window analysis. The confidence level of 0.99 was used to moderate false detection. Results: The algorithm was able to correctly detect anatomical changes in 6 out of 6 patients with an excellent spatial accuracy as early as at the 14th elapsed day. The algorithm provided a consistent and accurate delineation of the detected changes. The output of the anatomical change tool is easy interpretable, and can be shown overlaid on a 3D rendering of the patient's anatomy. Conclusion: The detection method provides the basis for one of the key components of Adaptive Radiation Therapy. The method uses tools that are readily available in the clinic, including daily CBCT imaging, and image co-registration facilities.

60 APPLIED LIFE SCIENCES↗