Search NASA⌕ Search

SEARCH · Search NASA

Results for “code comparisons”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

CXTFIT/Excel A modular adaptable code for parameter estimation, sensitivity analysis and uncertainty analysis for laboratory or field tracer experiments

We implemented the widely used CXTFIT code in Excel to provide flexibility and added sensitivity and uncertainty analysis functions to improve transport parameter estimation and to facilitate model discrimination for multi-tracer experiments on structured soils. Analytical solutions for one-dimensional equilibrium and nonequilibrium convection dispersion equations were coded as VBA functions so that they could be used as ordinary math functions in Excel for forward predictions. Macros with user-friendly interfaces were developed for optimization, sensitivity analysis, uncertainty analysis, error propagation, response surface calculation, and Monte Carlo analysis. As a result, any parameter with transformations (e.g., dimensionless, log-transformed, species-dependent reactions, etc.) could be estimated with uncertainty and sensitivity quantification for multiple tracer data at multiple locations and times. Prior information and observation errors could be incorporated into the weighted nonlinear least squares method with a penalty function. Users are able to change selected parameter values and view the results via embedded graphics, resulting in a flexible tool applicable to modeling transport processes and to teaching students about parameter estimation. The code was verified by comparing to a number of benchmarks with CXTFIT 2.0. It was applied to improve parameter estimation for four typical tracer experiment data sets in the literature using multi-model evaluation and comparison. Additional examples were included to illustrate the flexibilities and advantages of CXTFIT/Excel. The VBA macros were designed for general purpose and could be used for any parameter estimation/model calibration when the forward solution is implemented in Excel. A step-by-step tutorial, example Excel files and the code are provided as supplemental material.

54 ENVIRONMENTAL SCIENCES↗

Comparison of German and American fabrication standards for transportation and storage containments of high level radioactive material type B packages - 15055

As the competent authority for the evaluation of German radioactive material (RAM) transport and storage packages, BAM (the German Federal Institute for Materials Research and Testing) has evaluated various international cask manufacturers regarding compliance with the German Type B(U) licensing requirements. The US NRC has recommended paragraphs in the ASME Boiler and Pressure Vessel (B and PV) Code, Section III, Division 3, as the measure to quantify the safety requirements of the US regulations regarding fabrication of RAM transportation and storage containments. The objective of this study is to compare the fabrication criteria of the German Dangerous Goods Procedural Rules (BAM-GGR) and the German Institute for Standardization (DIN) with the US quantitative measures for fabrication of RAM package containment vessels. This comparison will cover major similarities and differences between the requirements of the German standards and the ASME Code requirements for Type B package containment fabrication QC (quality control). While the material most often used for German RAM containment applications is ductile cast iron (DCI), in the US forged austenitic stainless steel is typically used. This study focuses on fabrication QC measures required to ensure reproducible and acceptable properties for DCI containments. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparison of fission product release predictions using PARFUME with results from the AGR-1 safety tests

Safety tests were conducted on fourteen fuel compacts from AGR-1, the first irradiation experiment of the Advanced Gas Reactor (AGR) Fuel Development and Qualification program, at temperatures ranging from 1600 to 1800°C to determine fission product release at temperatures that bound reactor accident conditions. The PARFUME (PARticle FUel ModEl) code was used to predict the release of fission products silver, cesium, strontium, and krypton from fuel compacts containing tristructural isotropic (TRISO) coated particles during the safety tests, and the predicted values were compared with experimental results. Preliminary comparisons between PARFUME predictions and post-irradiation examination (PIE) results of the safety tests show different trends in the prediction of the fractional release depending on the species, and it leads to different conclusions regarding the diffusivities used in the modeling of fission product transport in TRISO-coated particles: • For silver, the diffusivity in silicon carbide (SiC) might be over-estimated by a factor of at least 102 to 103 at 1600°C and 1700°C, and at least 10 to 102 at 1800°C. The diffusivity of silver in uranium oxy-carbide (UCO) might also be over-estimated, but the available data are insufficient to allow definitive conclusions to be drawn. • For cesium, the diffusivity in UCO might be over-estimated by a factor of at least 102 to 103 at 1600°C, 105 at 1700°C, and 103 at 1800°C. The diffusivity of cesium in SiC might also over-estimated, by a factor of 10 at 1600°C and 103 at 1700°C, based upon the comparisons between calculated and measured release fractions from intact particles. There is no available estimate at 1800°C since all the compacts heated up at 1800°C contain particles with failed SiC layers whose release dominates the release from intact particles. • For strontium, the diffusivity in SiC might be over-estimated by a factor of 10 to 102 at 1600 and 1700°C, and 102 to 103 at 1800°C. These values might be somewhat over-estimated because the strontium retention during irradiation cannot be assessed a priori, which affects the magnitude of the calculated release during safety testing. The diffusivity of strontium in UCO cannot be derived from these heating tests, but it is assumed to be modeled correctly using the IAEA recommended value for kernel diffusivity. • For krypton, there is no reliable release data for compacts heated up at 1600°C, which includes all the compacts containing only intact particles. At 1700 and 1800°C, comparisons show an over-prediction of the release from compacts containing particles with failed SiC by 1 to 1.5 orders of magnitude. The available data from these heating tests do not allow to determine which of the TRISO-coating’s layers diffusivities are under or over-estimated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

3D hybrid fluid-particle jet simulations and the importance of synchrotron radiative losses

Context. Relativistic jets in active galactic nuclei are known for their exceptional energy output, and imaging the synthetic synchrotron emission of numerical jet simulations is essential for a comparison with observed jet polarization emission. Aims. Through the use of 3D hybrid fluid-particle jet simulations (with the PLUTO code), we overcome some of the commonly made assumptions in relativistic magnetohydrodynamic (RMHD) simulations by using non-thermal particle attributes to account for the resulting synchrotron radiation. Polarized radiative transfer and ray-tracing (via the RADMC-3D code) highlight the differences in total intensity maps when (i) the jet is simulated purely with the RMHD approach, (ii) a jet tracer is considered in the RMHD approach, and (iii) a hybrid fluid-particle approach is used. The resulting emission maps were compared to the example of the radio galaxy Centaurus A. Methods. We applied the Lagrangian particle module implemented in the latest version of the PLUTO code. This new module contains a state-of-the-art algorithm for modeling diffusive shock acceleration and for accounting for radiative losses in RMHD jet simulations. The module implements the physical postulates missing in RMHD jet simulations by accounting for a cooled ambient medium and strengthening the central jet emission. Results. We find a distinction between the innermost structure of the jet and the back-flowing material by mimicking the radio emission of the Seyfert II radio galaxy Centaurus A when considering an edge-brightened jet with an underlying purely toroidal magnetic field. We demonstrate the necessity of synchrotron cooling as well as the improvements gained when directly accounting for non-thermal synchrotron radiation via non-thermal particles.

79 ASTRONOMY AND ASTROPHYSICS↗

Unrestricted density functional theory based on the fragment molecular orbital method for the ground and excited state calculations of large systems

We extended the fragment molecular orbital (FMO) method interfaced with density functional theory (DFT) into spin unrestricted formalism (UDFT) and developed energy gradients for the ground state and single point excited state energies based on time-dependent DFT. The accuracy of FMO is evaluated in comparison to the full calculations without fragmentation. Electronic excitations in solvated organic radicals and in the blue copper protein, plastocyanin (PDB code: 1BXV), are reported. The contributions of solvent molecules to the electronic excitations are analyzed in terms of the fragment polarization and quantum effects such as interfragment charge transfer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SimProp: a simulation code for ultra high energy cosmic ray propagation

A new Monte Carlo simulation code for the propagation of Ultra High Energy Cosmic Rays is presented. The results of this simulation scheme are tested by comparison with results of another Monte Carlo computation as well as with the results obtained by directly solving the kinetic equation for the propagation of Ultra High Energy Cosmic Rays. A short comparison with the latest flux published by the Pierre Auger collaboration is also presented.

79 ASTRONOMY AND ASTROPHYSICS↗

Perennial rhizomatous grasses as bioenergy feedstock in SWAT: parameter development and model improvement

The Soil and Water Assessment Tool (SWAT) is increasingly used to quantify hydrologic and water quality impacts of bioenergy production, but crop-growth parameters for candidate perennial rhizomatous grasses (PRG) Miscanthus × giganteus and upland ecotypes of Panicum virgatum (switchgrass) are limited by the availability of field data. Crop-growth parameter ranges and suggested values were developed in this study using agronomic and weather data collected at the Purdue University Water Quality Field Station in northwestern Indiana. During the process of parameterization, the comparison of measured data with conceptual representation of PRG growth in the model led to three changes in the SWAT 2009 code: the harvest algorithm was modified to maintain belowground biomass over winter, plant respiration was extended via modified-DLAI to better reflect maturity and leaf senescence, and nutrient uptake algorithms were revised to respond to temperature, water, and nutrient stress. Parameter values and changes to the model resulted in simulated biomass yield and leaf area index consistent with reported values for the region. Code changes in the SWAT model improved nutrient storage during dormancy period and nitrogen and phosphorus uptake by both switchgrass and Miscanthus.

59 BASIC BIOLOGICAL SCIENCES↗

TH-E-18A-01: Developments in Monte Carlo Methods for Medical Imaging

Monte Carlo simulation methods are widely used in medical physics research and are starting to be implemented in clinical applications such as radiation therapy planning systems. Monte Carlo simulations offer the capability to accurately estimate quantities of interest that are challenging to measure experimentally while taking into account the realistic anatomy of an individual patient. Traditionally, practical application of Monte Carlo simulation codes in diagnostic imaging was limited by the need for large computational resources or long execution times. However, recent advancements in high-performance computing hardware, combined with a new generation of Monte Carlo simulation algorithms and novel postprocessing methods, are allowing for the computation of relevant imaging parameters of interest such as patient organ doses and scatter-to-primaryratios in radiographic projections in just a few seconds using affordable computational resources. Programmable Graphics Processing Units (GPUs), for example, provide a convenient, affordable platform for parallelized Monte Carlo executions that yield simulation times on the order of 10{sup 7} xray/ s. Even with GPU acceleration, however, Monte Carlo simulation times can be prohibitive for routine clinical practice. To reduce simulation times further, variance reduction techniques can be used to alter the probabilistic models underlying the x-ray tracking process, resulting in lower variance in the results without biasing the estimates. Other complementary strategies for further reductions in computation time are denoising of the Monte Carlo estimates and estimating (scoring) the quantity of interest at a sparse set of sampling locations (e.g. at a small number of detector pixels in a scatter simulation) followed by interpolation. Beyond reduction of the computational resources required for performing Monte Carlo simulations in medical imaging, the use of accurate representations of patient anatomy is crucial to the virtual generation of medical images and accurate estimation of radiation dose and other imaging parameters. For this, detailed computational phantoms of the patient anatomy must be utilized and implemented within the radiation transport code. Computational phantoms presently come in one of three format types, and in one of four morphometric categories. Format types include stylized (mathematical equation-based), voxel (segmented CT/MR images), and hybrid (NURBS and polygon mesh surfaces). Morphometric categories include reference (small library of phantoms by age at 50th height/weight percentile), patient-dependent (larger library of phantoms at various combinations of height/weight percentiles), patient-sculpted (phantoms altered to match the patient's unique outer body contour), and finally, patient-specific (an exact representation of the patient with respect to both body contour and internal anatomy). The existence and availability of these phantoms represents a very important advance for the simulation of realistic medical imaging applications using Monte Carlo methods. New Monte Carlo simulation codes need to be thoroughly validated before they can be used to perform novel research. Ideally, the validation process would involve comparison of results with those of an experimental measurement, but accurate replication of experimental conditions can be very challenging. It is very common to validate new Monte Carlo simulations by replicating previously published simulation results of similar experiments. This process, however, is commonly problematic due to the lack of sufficient information in the published reports of previous work so as to be able to replicate the simulation in detail. To aid in this process, the AAPM Task Group 195 prepared a report in which six different imaging research experiments commonly performed using Monte Carlo simulations are described and their results provided. The simulation conditions of all six cases are provided in full detail, with all necessary data on material composition, source, geometry, scoring and other parameters provided. The results of these simulations when performed with the four most common publicly available Monte Carlo packages are also provided in tabular form. The Task Group 195 Report will be useful for researchers needing to validate their Monte Carlo work, and for trainees needing to learn Monte Carlo simulation methods. In this symposium we will review the recent advancements in highperformance computing hardware enabling the reduction in computational resources needed for Monte Carlo simulations in medical imaging. We will review variance reduction techniques commonly applied in Monte Carlo simulations of medical imaging systems and present implementation strategies for efficient combination of these techniques with GPU acceleration. Trade-offs involved in Monte Carlo acceleration by means of denoising and “sparse sampling” will be discussed. A method for rapid scatter correction in cone-beam CT (<5 min/scan) will be presented as an illustration of the simulation speeds achievable with optimized Monte Carlo simulations. We will also discuss the development, availability, and capability of the various combinations of computational phantoms for Monte Carlo simulation of medical imaging systems. Finally, we will review some examples of experimental validation of Monte Carlo simulations and will present the AAPM Task Group 195 Report. Learning Objectives: Describe the advances in hardware available for performing Monte Carlo simulations in high performance computing environments. Explain variance reduction, denoising and sparse sampling techniques available for reduction of computational time needed for Monte Carlo simulations of medical imaging. List and compare the computational anthropomorphic phantoms currently available for more accurate assessment of medical imaging parameters in Monte Carlo simulations. Describe experimental methods used for validation of Monte Carlo simulations in medical imaging. Describe the AAPM Task Group 195 Report and its use for validation and teaching of Monte Carlo simulations in medical imaging.

60 APPLIED LIFE SCIENCES↗

ExpM+NF MIMIC III experiments

This code allows reproduction of results in the paper "Are Normalizing Flows the Key to Unlocking the Exponential Mechanism? " https://arxiv.org/abs/2311.09200 The code here provides implementation of our experiments where we test if we can training models with ExpM+NF alongside and in comparison with DPSGD and non-private training.

Tombs, VandyJ↗

The Genome of Ganderma lucidum Provide Insights into Triterpense Biosynthesis and Wood Degradation

Ganoderma lucidum (Reishi or Ling Zhi) is one of the most famous Traditional Chinese Medicines and has been widely used in the treatment of various human diseases in Asia countries. It is also a fungus with strong wood degradation ability with potential in bioenergy production. However, genes, pathways and mechanisms of these functions are still unknown. The genome of G. lucidum was sequenced and assembled into a 39.9 megabases (Mb) draft genome, which encoded 12,080 protein-coding genes and ~83% of them were similar to public sequences. We performed comprehensive annotation for G. lucidum genes and made comparisons with genes in other fungi genomes. Genes in the biosynthesis of the main G. lucidum active ingredients, ganoderic acids (GAs), were characterized. Among the GAs synthases, we identified a fusion gene, the N and C terminal of which are homologous to two different enzymes. Moreover, the fusion gene was only found in basidiomycetes. As a white rot fungus with wood degradation ability, abundant carbohydrate-active enzymes and ligninolytic enzymes were identified in the G. lucidum genome and were compared with other fungi. : The genome sequence and well annotation of G. lucidum will provide new insights in function analyses including its medicinal mechanism. The characterization of genes in the triterpene biosynthesis and wood degradation will facilitate bio-engineering research in the production of its active ingredients and bioenergy.

59 BASIC BIOLOGICAL SCIENCES↗

SNEWPY: A Data Pipeline from Supernova Simulations to Neutrino Signals

Current neutrino detectors will observe hundreds to thousands of neutrinos from a Galactic supernovae, and future detectors will increase this yield by an order of magnitude or more. With such a data set comes the potential for a huge increase in our understanding of the explosions of massive stars, nuclear physics under extreme conditions, and the properties of the neutrino. However, there is currently a large gap between supernova simulations and the corresponding signals in neutrino detectors, which will make any comparison between theory and observation very difficult. SNEWPY is an open-source software package which bridges this gap. The SNEWPY code can interface with supernova simulation data to generate from the model either a time series of neutrino spectral fluences at Earth, or the total time-integrated spectral fluence. Data from several hundred simulations of core-collapse, thermonuclear, and pair-instability supernovae is included in the package. This output may then be used by an event generator such as sntools or an event rate calculator such as SNOwGLoBES. Additional routines in the SNEWPY package automate the processing of the generated data through the SNOwGLoBES software and collate its output into the observable channels of each detector. In this paper we describe the contents of the package, the physics behind SNEWPY, the organization of the code, and provide examples of how to make use of its capabilities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Coupled thermomechanical modeling using dissimilar geometries in arpeggio.

Performing coupled thermomechanical simulations is becoming an increasingly important aspect of nuclear weapon (NW) safety assessments in abnormal thermal environments. While such capabilities exist in SIERRA, they have thus far been used only in a limited sense to investigate NW safety themes. An important limiting factor is the difficulty associated with developing geometries and meshes appropriate for both thermal and mechanical finite element models, which has limited thermomechanical analysis to simplified configurations. This work addresses the issue of how to perform coupled analyses on models where the underlying geometries and associated meshes are different and tailored to their relevant physics. Such an approach will reduce the model building effort and enable previously developed single-physics models to be leveraged in future coupled simulations. A combined-environment approach is presented in this report using SIERRA tools, with quantitative comparisons made between different options in SIERRA. This report summarizes efforts on running a coupled thermomechanical analysis using the SIERRA Arpeggio code.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

REACTION SAMPLING IN MCATK: Using the Thermal Motion of the Target Nucleus to Perform Elastic and Inelastic Scattering (U)

We describe how the reaction sampling is currently performed in MCATK. The current reaction sampling method is modeled on the method coded in MCNP6 and briefly described in the MCNP manual. The method is validated using the MCATK criticality validation suite for comparison with MCNP6. The results of this validation suite show good agreement with results obtained with MCNP6.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Raytracing Project: Graybody Approximation [Slides]

Graybody approximation is first step to infrared raytracing code. Graybody approximation can capture temperature, but obviously cannot be used for gas species characterization. Graybody approximation will be used for comparisons to experimental data that is integrated across wavenumber.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CMM Sequential Analysis Program

This report documents a design agency (DA) method to evaluate coordinate measuring machine (CMM) data by constructing an algorithm that is equivalent to the production agency (PA) algorithm for processing the raw CMM data. Several refinements of the CMM analyses were implemented at both the PA and the DA to process inherent limitations of the raw data, such as the absence of measurements at the exact ends of the connector-adapter assembly (CAA) and the recovery from these limitations through (worst-case) adjustments to the the positional errors. Also, inherent errors of the CMM measurements were accommodated by introducing a guard band, which effectively lowered the tolerance so that the CMM code could not pass bad parts. The DA and the PA showed remarkable agreement in all areas of analysis. The ultimate comparison is shown in Figures 13a and 13b, where the effect of using a guard band and end adjustments to the CMM measurements were clearly shown.

42 ENGINEERING↗

Acceptance Testing of the Scorpius Sweep Magnet

A beam-dump magnet for Scorpius has been defined by LANL and designed and built by Radiabeam Technologies. Initial verification of the Radiabeam design used a magnetic field model provided by Radiabeam and analyzed by LANL tools during September 2021. Simulations indicated that the design was sufficient to meet deflection requirements to protect sensitive equipment in the case of a failed target. In January 2022, the magnet was fabricated and Radiabeam conducted measurements of the magnetic field as a function of position. The measurements deviate somewhat from the simulation. In particular, the peak magnetic field is 10-15% smaller in magnitude than expected from simulation. This note compares the magnetic field measurements to simulation and to measurements of the existing DARHT magnet, which was designed for the same purpose. We show a comparison of the measured beam deflection performance between Scorpius and DARHT and show updated results of LANL’s electron beam tracking code using the Scorpius measurements. Using field measurements we find that the DARHT magnet will deflect a 19.6 MeV electron beam by 46.6° and the Scorpius magnet will deflect by 44.6°. These results show that the as-built Scorpius magnet has met design requirements for beam deflection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Summary of LANL Critical Benchmark Comparison Study and Revisions for Cases Involving HEU, LEU, MIX, and Pu

This report documents results obtained for revisions made to cases involving Highly Enriched Uranium (HEU), Intermediate Enriched Uranium (IEU), a mixture of Pu and Uranium (MIX), as well as Pu cases. A previous summary of revisions for HEU an Pu cases was reported and additional investigations into four cases originally presented therein uncovered further revisions which led to better agreement with other transport codes, those cases are updated in this report. The summary of all cases reported in Reference 2 is updated in this report. In addition, a previous summary of revisions for LEU and MIX was reported, a summary of those revisions in reproduced in this report for a comprehensive summary of changes to benchmarks beginning in fiscal year 2020 to current date. The report focuses on the changes made to LANL benchmarks modeled with MCNP6 using ENDF/B-VII.1 nuclear data that appeared to have discrepant results when compared with results of other codes. Feedback was used to pinpoint review of benchmark input files and to revise them when necessary. This report documents the results of review and revision of specific benchmarks highlighted as possibly discrepant in the comparison study. In addition, there is an effort tied to this work involving collaboration between LANL XCP and NCS Divisions in the development of a shared review/revision procedure and use of a new benchmark repository. LANL has a benchmark library of critical experiments from the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook modeled for use with MCNP. This collection is now over 1100 benchmarks, referred to as the Whisper-1.1 library because it is used with the sensitivity/uncertainty package, Whisper, which supports nuclear criticality safety validation and is released with MCNP6.2. The collection, originally created several decades ago, is a combination of smaller collections, which has been revised and expanded, by various groups at LANL over the years. The original authors are no longer at the laboratory and little formal documentation of review and revision of these benchmarks exists today. A branch of the benchmark collection was already the subject of a formal review undertaken by the LANL NCS Division and expanded to include XCP Division.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurements of Separate Neutron and Gamma-Ray Coincidences with Liquid Scintillators and Digital PSD Technique

A new technique is presented for the measurement of neutron and/or gamma-ray coincidences. Separate neutron neutron, neutron gamma-ray, gamma-ray neutron, and gamma-ray gamma-ray coincidences are acquired with liquid scintillation detectors and a digital pulse shape discrimination (PSD) technique based on standard charge integration method. The measurement technique allows for the collection of fast coincidences in a time window of the order of a few tens of nanoseconds between the coincident particles. The PSD allows for the acquisition of the coincidences in all particle combinations. The measurements are compared to results obtained with the MCNP-PoliMi code, which simulates neutron and gamma-ray coincidences from from a source on an event-by-event basis. This comparison leads to good qualitative agreement.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗