Search NASA⌕ Search

SEARCH · Search NASA

Results for “computable error estimate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

A Müntz wavelets collocation method for solving fractional differential equations

In this paper, we introduce a new set of wavelets, namely Müntz wavelets. These wavelets are defined based on Müntz Legendre polynomials which have the property of orthogonality. We stabilize the wavelet coefficients by utilizing Jacobi polynomials to construct the modified Müntz wavelets. Next, we present a collocation scheme based on Müntz wavelets for solving fractional differential equations. The fractional derivative is described in the Caputo sense. Some error estimates are given and numerical examples are included to demonstrate the applicability and accuracy of the proposed method. This includes the elastic-dissipative mathematical model of linear mechanical devices known as Boltzman operator.

97 MATHEMATICS AND COMPUTING↗

A unified hp-HDG framework for Friedrichs' PDE systems

Here, this work proposes a unified hp-adaptivity framework for hybridized discontinuous Galerkin (HDG) method for a large class of partial differential equations (PDEs) of Friedrichs' type. In particular, we present unified hp-HDG formulations for abstract one-field and two-field structures and prove their well-posedness. In order to handle non-conforming interfaces we simply take advantage of HDG built-in mortar structures. With split-type mortars and the approximation space of trace, a numerical flux can be derived via Godunov approach and be naturally employed without any additional treatment. As a consequence, the proposed formulations are parameter-free. We perform several numerical experiments for time-independent and linear PDEs including elliptic, hyperbolic, and mixed-type to verify the proposed unified hp-formulations and demonstrate the effectiveness of hp-adaptation. Two adaptivity criteria are considered: one is based on a simple and fast error indicator, while the other is rigorous but more expensive using an adjoint-based error estimate. The numerical results show that these two approaches are comparable in terms of convergence rate even for problems with strong gradients, discontinuities, and singularities.

97 MATHEMATICS AND COMPUTING↗

3D localization of electrophysiology catheters from a single x-ray cone-beam projection

Purpose: X-ray images allow the visualization of percutaneous devices such as catheters in real time but inherently lack depth information. The provision of 3D localization of these devices from cone beam x-ray projections would be advantageous for interventions such as electrophysiology (EP), whereby the operator needs to return a device to the same anatomical locations during the procedure. A method to achieve real-time 3D single view localization (SVL) of an object of known geometry from a single x-ray image is presented. SVL exploits the change in the magnification of an object as its distance from the x-ray source is varied. The x-ray projection of an object of interest is compared to a synthetic x-ray projection of a model of said object as its pose is varied. Methods: SVL was tested with a 3 mm spherical marker and an electrophysiology catheter. The effect of x-ray acquisition parameters on SVL was investigated. An independent reference localization method was developed to compare results when imaging a catheter translated via a computer controlled three-axes stage. SVL was also performed on clinical fluoroscopy image sequences. A commercial navigation system was used in some clinical image sequences for comparison. Results: SVL estimates exhibited little change as x-ray acquisition parameters were varied. The reproducibility of catheter position estimates in phantoms denoted by the standard deviations, (σ{sub x}, σ{sub y}, σ{sub z}) = (0.099 mm, 0.093 mm, 2.2 mm), where x and y are parallel to the detector plane and z is the distance from the x-ray source. Position estimates (x, y, z) exhibited a 4% systematic error (underestimation) when compared to the reference method. The authors demonstrated that EP catheters can be tracked in clinical fluoroscopic images. Conclusions: It has been shown that EP catheters can be localized in real time in phantoms and clinical images at fluoroscopic exposure rates. Further work is required to characterize performance in clinical images as well as the sensitivity to clinical image quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of an equation‐oriented framework to formulate and estimate parameters of chemical looping reaction models

Abstract Accurate, predictive reaction models are critical for the design and optimization of chemical looping combustion (CLC) reactors. The formulation and estimation of kinetic parameters for these reaction models using a first‐principles equation‐oriented (EO) approach is particularly beneficial as large amounts of experimental data spanning process‐relevant conditions can be used to estimate parameters in a computationally tractable way. This work demonstrates the application of a novel EO framework to develop reduction reaction kinetic models of an iron‐based CLC oxygen carrier (OC). An optimization problem is formulated to estimate kinetic parameters that provide the best fit to the experimental data. The model predicts the state of the OC with mean square error values of 2.5%–4.4% across the full range of validation data, including multiple reduction cycles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Systematic problems with using dark matter simulations to model stellar halos

The limits of available computing power have forced models for the structure of stellar halos to adopt one or both of the following simplifying assumptions: (1) stellar mass can be 'painted' onto dark matter (DM) particles in progenitor satellites; (2) pure DM simulations that do not form a luminous galaxy can be used. We estimate the magnitude of the systematic errors introduced by these assumptions using a controlled set of stellar halo models where we independently vary whether we look at star particles or painted DM particles, and whether we use a simulation in which a baryonic disk galaxy forms or a matching pure DM simulation that does not form a baryonic disk. We find that the 'painting' simplification reduces the halo concentration and internal structure, predominantly because painted DM particles have different kinematics from star particles even when both are buried deep in the potential well of the satellite. The simplification of using pure DM simulations reduces the concentration further, but increases the internal structure, and results in a more prolate stellar halo. These differences can be a factor of 1.5-7 in concentration (as measured by the half-mass radius) and 2-7 in internal density structure. Given this level of systematic uncertainty, one should be wary of overinterpreting differences between observations and the current generation of stellar halo models based on DM-only simulations when such differences are less than an order of magnitude.

79 ASTRONOMY AND ASTROPHYSICS↗

On the regularity of the covariance matrix of a discretized scalar field on the sphere

We present a comprehensive study of the regularity of the covariance matrix of a discretized field on the sphere. In a particular situation, the rank of the matrix depends on the number of pixels, the number of spherical harmonics, the symmetries of the pixelization scheme and the presence of a mask. Taking into account the above mentioned components, we provide analytical expressions that constrain the rank of the matrix. They are obtained by expanding the determinant of the covariance matrix as a sum of determinants of matrices made up of spherical harmonics. We investigate these constraints for five different pixelizations that have been used in the context of Cosmic Microwave Background (CMB) data analysis: Cube, Icosahedron, Igloo, GLESP and HEALPix, finding that, at least in the considered cases, the HEALPix pixelization tends to provide a covariance matrix with a rank closer to the maximum expected theoretical value than the other pixelizations. The effect of the propagation of numerical errors in the regularity of the covariance matrix is also studied for different computational precisions, as well as the effect of adding a certain level of noise in order to regularize the matrix. In addition, we investigate the application of the previous results to a particular example that requires the inversion of the covariance matrix: the estimation of the CMB temperature power spectrum through the Quadratic Maximum Likelihood algorithm. Finally, some general considerations in order to achieve a regular covariance matrix are also presented.

79 ASTRONOMY AND ASTROPHYSICS↗

Integrating proteomic or transcriptomic data into metabolic models using linear bound flux balance analysis

Abstract Motivation Transcriptomics and proteomics data have been integrated into constraint-based models to influence flux predictions. However, it has been reported recently for Escherichia coli and Saccharomyces cerevisiae, that model predictions from parsimonious flux balance analysis (pFBA), which does not use expression data, are as good or better than predictions from various algorithms that integrate transcriptomics or proteomics data into constraint-based models. Results In this paper, we describe a novel constraint-based method called Linear Bound Flux Balance Analysis (LBFBA), which uses expression data (either transcriptomic or proteomic) to predict metabolic fluxes. The method uses expression data to place soft constraints on individual fluxes, which can be violated. Parameters in the soft constraints are first estimated from a training expression and flux dataset before being used to predict fluxes from expression data in other conditions. We applied LBFBA to E.coli and S.cerevisiae datasets and found that LBFBA predictions were more accurate than pFBA predictions, with average normalized errors roughly half of those from pFBA. For the first time, we demonstrate a computational method that integrates expression data into constraint-based models and improves quantitative flux predictions over pFBA. Availability and implementation Code is available in the Supplementary data available at Bioinformatics online. Supplementary information Supplementary data are available at Bioinformatics online.

Tian, Mingyuan↗

Uncertainty quantification for deep learning in particle accelerator applications

With the advent of increased computational resources and improved algorithms, machine learning-based models are being increasingly applied to complex problems in particle accelerators. However, such data-driven models may provide overly confident predictions with unknown errors and uncertainties. For reliable deployment of machine learning models in high-regret and safety-critical systems such as particle accelerators, estimates of prediction uncertainty are needed along with accurate point predictions. In this investigation, we evaluate Bayesian neural networks (BNN) as an approach that can provide accurate predictions along with reliably quantified uncertainties for particle accelerator problems, and compare their performance with bootstrapped ensembles of neural networks. We select three accelerator setups for this evaluation: a storage ring, a photoinjector, and a linac. The problems span different data volumes and dimensionalities (e.g., scalar predictions as well as image outputs). It is found that BNN provide accurate predictions of the mean along with reliable estimates of predictive uncertainty across the test cases. In this vein, BNN may offer an attractive alternative to deterministic deep learning tools to generate accurate predictions with quantified uncertainties in particle accelerator applications.

43 PARTICLE ACCELERATORS↗

TH-A-BRF-01: A Probabilistic Bayesian Approach to Derive Electron Density From MRI for Radiation Therapy Treatment Planning

Purpose: MRI significantly improves the accuracy and reliability of target delineation for patient simulation and treatment planning in radiation therapy, due to its superior soft tissue contrast as compared to CT. An MRI based simulation will reduce cost and simplify clinical workflow with zero ionizing radiation. However, MRI lacks the key electron density information. The purpose of this work is to develop a reliable method to derive electron density from MRI. Methods: We adopt a probabilistic Bayesian approach for electron density mapping based on T1-weighted head MRI. For each voxel, we compute conditional probability of electron densities given its: (1) T1 intensity and (2) geometry in a reference anatomy, obtained by deformable image registration between the MRI of test patient and atlas. Intensity and geometry information are combined into a unifying posterior probability density function whose mean gives the electron density. Mean absolute HU error between the estimated and true CT, as well as ROC's for bone detection (HU>200) were calculated for 8 patients. The performance was compared with a global intensity approach based on T1 and no density correction (set whole head to water). Results: The proposed technique significantly reduced the errors in electron density estimation, with a mean absolute HU error of 132, compared with 139 for deformable registration (p=10{sup −3}), 371 for the intensity approach (p=10{sup −5}) and 282 without density correction (p=2×10{sup −4}). For 90% sensitivity in bone detection, the proposed method had a specificity of 85% and that for deformable registration, intensity and without density correction are 80%, 24% and 10% respectively. Conclusion: The proposed unifying method provides accurate electron density estimation and bone detection from MRI of the head with highly heterogeneous regions. This paves the way for accurate dose calculation and generating reference images for patient setup in MRI-based treatment planning.

60 APPLIED LIFE SCIENCES↗

Rotorcraft system identification techniques for handling qualities and stability and control evaluation

An integrated approach to rotorcraft system identification is described. This approach consists of sequential application of (1) data filtering to estimate states of the system and sensor errors, (2) model structure estimation to isolate significant model effects, and (3) parameter identification to quantify the coefficient of the model. An input design algorithm is described which can be used to design control inputs which maximize parameter estimation accuracy. Details of each aspect of the rotorcraft identification approach are given. Examples of both simulated and actual flight data processing are given to illustrate each phase of processing. The procedure is shown to provide means of calibrating sensor errors in flight data, quantifying high order state variable models from the flight data, and consequently computing related stability and control design models.

Hall, W. E., Jr.↗

Anytime synthetic projection: Maximizing the probability of goal satisfaction

A projection algorithm is presented for incremental control rule synthesis. The algorithm synthesizes an initial set of goal achieving control rules using a combination of situation probability and estimated remaining work as a search heuristic. This set of control rules has a certain probability of satisfying the given goal. The probability is incrementally increased by synthesizing additional control rules to handle 'error' situations the execution system is likely to encounter when following the initial control rules. By using situation probabilities, the algorithm achieves a computationally effective balance between the limited robustness of triangle tables and the absolute robustness of universal plans.

Drummond, Mark↗

Use of IRI to Model the Effect of Ionosphere Emission on Earth Remote Sensing at L-Band

Microwave remote sensing in the window at 1.413 GHz (L-band) set aside for passive use only is important for monitoring sea surface salinity and soil moisture. These parameters are important for understanding ocean dynamics and energy exchange between the surface and atmosphere, and both NASA and ESA plan to launch satellite sensors to monitor these parameters at L-band (Aquarius, Hydros and SMOS). The ionosphere is an important source of error for passive remote sensing at this frequency. In addition to Faraday rotation, emission from the ionosphere is also a potential source of error at L-band. As an aid for correcting for emission, a regression model is presented that relates ionosphere emission to the integrated electron density (TEC). The goal is to use TEC from sources such as TOPEX, JASON or GPS to obtain estimates of emission over the oceans where the electron density profiles needed to compute emission are not available. In addition, data will also be presented to evaluate the use of the IRI for computing emission over the ocean.

Abraham, Saji↗

An Iterated Global Mascon Solution with Focus on Land Ice Mass Evolution

Land ice mass evolution is determined from a new GRACE global mascon solution. The solution is estimated directly from the reduction of the inter-satellite K-band range rate observations taking into account the full noise covariance, and formally iterating the solution. The new solution increases signal recovery while reducing the GRACE KBRR observation residuals. The mascons are estimated with 10-day and 1-arc-degree equal area sampling, applying anisotropic constraints for enhanced temporal and spatial resolution of the recovered land ice signal. The details of the solution are presented including error and resolution analysis. An Ensemble Empirical Mode Decomposition (EEMD) adaptive filter is applied to the mascon solution time series to compute timing of balance seasons and annual mass balances. The details and causes of the spatial and temporal variability of the land ice regions studied are discussed.

Luthcke, S. B.↗

Digitizing gauge fields: Lattice Monte Carlo results for future quantum computers

We report that in the near-future noisy intermediate-scale quantum (NISQ) era of quantum computing technology, applications of quantum computing will be limited to calculations of very modest scales in terms of the number of qubits used. The need to represent numeric quantities using limited resources leads to digitization errors which must be taken into account. As a first step towards quantum simulations of realistic high-energy physics problems, we explore classically the effects of digitizing elements of the $\mathrm{SU}(2)$ gauge group to a finite set. We consider several methods for digitizing the group, finding the best performance from an action-preserving projection onto a mesh. Working in (3+1) dimensions, we find that using $\sim 7$ (qu)bits to represent each $\mathrm{SU}(2)$ gauge link induces a digitization error on the order of $10\%$ in short-distance observables and $2\%$ in long-distance observables. Promisingly, our results indicate that each $\mathrm{SU}(2)$ gauge link can be represented by $\mathcal{O}(10)$ (qu)bits, from which we estimate that a $16^3$ $\mathrm{SU}(2)$ lattice could be simulated with no more than $\mathcal{O}(10^5)$ (qu)bits. Lastly, our results on digitization are also of interest as a form of lossy compression that could be used in high-performance classical computing to alleviate communications bottlenecks.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A linear, separable two-parameter model for dual energy CT imaging of proton stopping power computation

Purpose: To evaluate the accuracy and robustness of a simple, linear, separable, two-parameter model (basis vector model, BVM) in mapping proton stopping powers via dual energy computed tomography (DECT) imaging. Methods: The BVM assumes that photon cross sections (attenuation coefficients) of unknown materials are linear combinations of the corresponding radiological quantities of dissimilar basis substances (i.e., polystyrene, CaCl{sub 2} aqueous solution, and water). The authors have extended this approach to the estimation of electron density and mean excitation energy, which are required parameters for computing proton stopping powers via the Bethe–Bloch equation. The authors compared the stopping power estimation accuracy of the BVM with that of a nonlinear, nonseparable photon cross section Torikoshi parametric fit model (VCU tPFM) as implemented by the authors and by Yang et al. [“Theoretical variance analysis of single- and dual-energy computed tomography methods for calculating proton stopping power ratios of biological tissues,” Phys. Med. Biol. 55, 1343–1362 (2010)]. Using an idealized monoenergetic DECT imaging model, proton ranges estimated by the BVM, VCU tPFM, and Yang tPFM were compared to International Commission on Radiation Units and Measurements (ICRU) published reference values. The robustness of the stopping power prediction accuracy of tissue composition variations was assessed for both of the BVM and VCU tPFM. The sensitivity of accuracy to CT image uncertainty was also evaluated. Results: Based on the authors’ idealized, error-free DECT imaging model, the root-mean-square error of BVM proton stopping power estimation for 175 MeV protons relative to ICRU reference values for 34 ICRU standard tissues is 0.20%, compared to 0.23% and 0.68% for the Yang and VCU tPFM models, respectively. The range estimation errors were less than 1 mm for the BVM and Yang tPFM models, respectively. The BVM estimation accuracy is not dependent on tissue type and proton energy range. The BVM is slightly more vulnerable to CT image intensity uncertainties than the tPFM models. Both the BVM and tPFM prediction accuracies were robust to uncertainties of tissue composition and independent of the choice of reference values. This reported accuracy does not include the impacts of I-value uncertainties and imaging artifacts and may not be achievable on current clinical CT scanners. Conclusions: The proton stopping power estimation accuracy of the proposed linear, separable BVM model is comparable to or better than that of the nonseparable tPFM models proposed by other groups. In contrast to the tPFM, the BVM does not require an iterative solving for effective atomic number and electron density at every voxel; this improves the computational efficiency of DECT imaging when iterative, model-based image reconstruction algorithms are used to minimize noise and systematic imaging artifacts of CT images.

61 RADIATION PROTECTION AND DOSIMETRY↗

Bayesian and LASSO Regressions for Comparative Permeability Modeling of Sandstone Reservoirs

In this research, Bayesian model averaging (BMA) and least absolute shrinkage and selection operator regression (LASSO) algorithms were adopted for the core permeability modeling as a function of well log and core measurements. More specifically, the core permeability (dependent factor) was modeled given the well log and core data (independent variables) and then predicted in non-cored intervals of a well in a sandstone formation. The BMA is a stochastic linear modeling and a Bayesian parameter selection. Among 50 linear models generated as a function of the independent variables and depicted in Occam’s window, the best model of the highest posterior probability is determined. The best model has the optimal subset parameters that most influences the response factor. The core permeability modeling was again conducted using the LASSO algorithm, which adopts a completely different way of modeling and subset selection by using the penalized least-squared equation. Both BMA and LASSO resulted in a very accurate prediction of the core permeability by achieving perfect measured and calculated permeability matching. Matches for the two algorithms were quantified by computing the adjusted R-squared and root-mean-squared prediction error. In addition, results of the BMA and LASSO were compared to the conventional multiple linear regression (LM). The LASSO algorithm led to an accurate matching similar to LM, but slightly better than BMA. Therefore, both BMA and LASSO represent integrated procedures for accurate permeability estimation similar to conventional regression analysis.

58 GEOSCIENCES↗

Stochastic multiscale modeling for quantifying statistical and model errors with application to composite materials

This paper provides a coherent and efficient computational framework for stochastic multiscale analysis of material systems in the presence of parametric uncertainties and modeling errors. Uncertainty in those model parameters that are not deduced as upscaled quantities is attributed to an uncertainty “germ”. While such parameters can appear at any scale, they are predominant at the finest analysis scale. Additional uncertainties stemming from statistical estimation, attributed to lack of data and model error, are associated with each submodel contributing to the multiscale system. Here, a robust and efficient framework based on a generalized extended polynomial chaos expansion (gEPCE) is proposed to simultaneously propagate all these uncertainties in order to provide a probabilistic representation of specific quantities of interest (QoI). We characterize the full probability distribution of the QoI and the uncertainty in the failure probability pertaining to its tails. By combining gEPCE with kernel density estimation (KDE) and directional derivatives, we construct sensitivity measures that connect these statistical metrics of QoI to the various sources of uncertainty to assess their individual and combined impacts. An illustrative problem featuring three-point bending of a composite beam is investigated to demonstrate the presented approach.

36 MATERIALS SCIENCE↗

An Automated Thermochemistry Protocol Based on Explicitly Correlated Coupled-Cluster Theory: The Methyl and Ethyl Peroxy Families

An automated computational thermochemistry protocol based on explicitly correlated coupled-cluster theory was determined to produce highly accurate enthalpies of formation and atomization energies for small- to medium-sized molecular species (3–12 atoms). Each possible source of error was carefully examined, and the sizes of contributions to the total atomization enthalpies were used to generate uncertainty estimates. The protocol was first used to generate total atomization enthalpies for a family of four molecular species exhibiting a variety of charges, multiplicities, and electronic ground states. The new protocol was demonstrated to be in good agreement with the Active Thermochemical Tables database for the four species: the methyl peroxy radical, methoxyoxoniumylidene (methyl peroxy cation), methyl peroxy anion, and methyl hydroperoxide. Updating the Active Thermochemical Tables to include those results yielded significantly improved accuracy for the formation enthalpies of those species. The derived protocol was then used to predict formation enthalpies for the larger ethyl peroxy family of species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗