Assessing the Impacts of Two Averaging Methods on AIRS Level 3 Monthly Products and Multi-Year Monthly Means

The Atmospheric Infrared Sounder (AIRS) onboard NASA’s Aqua satellite provides more than 16 years of data. Its monthly gridded (Level 3) product has been widely used for climate research and applications. Since counts of successful soundings in a grid cell are used to derive monthly averages, this “Averaged By Observations (ABO)” approach effectively gives equal importance to all participating soundings within a month. It is conceivable, then, that days with more observations due to day-to-day orbit shift and regimes with better retrieval skills, will contribute disproportionately to the monthly average within a cell. Alternatively, the AIRS Level 3 monthly product can be produced through an "Averaged By Days (ABD)” approach, where the monthly mean in a grid cell is a simple average of the daily means. The effects of these averaging methods on the AIRS version 6 monthly product are assessed quantitatively using temperature and water vapor at surface and 500hPa. The ABO method results in a warmer (slightly colder) global mean temperature at surface (500hPa) and a drier global mean water vapor than ABD method. The AIRS multi-year monthly mean temperature and water vapor from both methods are also compared with the Modern-Era Retrospective analysis for Research and Applications – 2 (MERRA-2) product and evaluated with a simulation experiment, indicating the ABD method has less error and is more closely correlated with MERRA-2. In summary, the ABD method is recommended for future versions of the AIRS Level 3 monthly product and more data services supporting Level 3 aggregation are needed.

AIRS↗

Determination of the number of ψ(3686) events at BESIII

The numbers of ψ(3686) events accumulated by the BESIII detector for the data taken during 2009 and 2012 are determined to be $(107.0\pm 0.8)\times {10}^{6}$ and $(341.1\pm 2.1)\times {10}^{6}$, respectively, by counting inclusive hadronic events, where the uncertainties are systematic and the statistical uncertainties are negligible. The number of events for the sample taken in 2009 is consistent with that of the previous measurement. The total number of ψ(3686) events for the two data taking periods is $(448.1\pm 2.9)\times {10}^{6}$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

HIGH-RESOLUTION IMAGING OF THE ATLBS REGIONS: THE RADIO SOURCE COUNTS

The Australia Telescope Low-brightness Survey (ATLBS) regions have been mosaic imaged at a radio frequency of 1.4 GHz with 6'' angular resolution and 72 {mu}Jy beam{sup -1} rms noise. The images (centered at R.A. 00{sup h}35{sup m}00{sup s}, decl. -67 Degree-Sign 00'00'' and R.A. 00{sup h}59{sup m}17{sup s}, decl. -67 Degree-Sign 00'00'', J2000 epoch) cover 8.42 deg{sup 2} sky area and have no artifacts or imaging errors above the image thermal noise. Multi-resolution radio and optical r-band images (made using the 4 m CTIO Blanco telescope) were used to recognize multi-component sources and prepare a source list; the detection threshold was 0.38 mJy in a low-resolution radio image made with beam FWHM of 50''. Radio source counts in the flux density range 0.4-8.7 mJy are estimated, with corrections applied for noise bias, effective area correction, and resolution bias. The resolution bias is mitigated using low-resolution radio images, while effects of source confusion are removed by using high-resolution images for identifying blended sources. Below 1 mJy the ATLBS counts are systematically lower than the previous estimates. Showing no evidence for an upturn down to 0.4 mJy, they do not require any changes in the radio source population down to the limit of the survey. The work suggests that automated image analysis for counts may be dependent on the ability of the imaging to reproduce connecting emission with low surface brightness and on the ability of the algorithm to recognize sources, which may require that source finding algorithms effectively work with multi-resolution and multi-wavelength data. The work underscores the importance of using source lists-as opposed to component lists-and correcting for the noise bias in order to precisely estimate counts close to the image noise and determine the upturn at sub-mJy flux density.

79 ASTRONOMY AND ASTROPHYSICS↗

Half-life and gamma abundance ratio measurements of Sm-153

The measurement of the decay of 153Sm was observed by gamma spectrometry, liquid scintillation counting and gas proportional counting in an attempt to confirm the half life and gamma abundance ratios for this isotope. Recent changes in the published nuclear decay data indicate that historical literature values may be biased. The 153Sm was made by the neutron activation of ultrapure isotopically enriched 152Sm to create 153Sm. The decay measurements were made over a three week period and no other isotopes were detected during this time. The gamma abundance ratio for the 103 keV gamma was measured to be (27.9%) which is 4% lower than the published data. In addition, the half life was 1.9308 days, which is 0.34% lower than the published data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reconfigurable Computing As an Enabling Technology for Single-Photon-Counting Laser Altimetry

Single-photon-counting laser altimetry is a new measurement technique offering significant advantages in vertical resolution, reducing instrument size, mass, and power, and reducing laser complexity as compared to analog or threshold detection laser altimetry techniques. However, these improvements come at the cost of a dramatically increased requirement for onboard real-time data processing. Reconfigurable computing has been shown to offer considerable performance advantages in performing this processing. These advantages have been demonstrated on the Multi-KiloHertz Micro-Laser Altimeter (MMLA), an aircraft based single-photon-counting laser altimeter developed by NASA Goddard Space Flight Center with several potential spaceflight applications. This paper describes how reconfigurable computing technology was employed to perform MMLA data processing in real-time under realistic operating constraints, along with the results observed. This paper also expands on these prior results to identify concepts for using reconfigurable computing to enable spaceflight single-photon-counting laser altimeter instruments.

Powell, Wesley↗

Sci—Thur PM: Imaging — 05: Calibration of a SPECT/CT camera for quantitative SPECT with {sup 99m}Tc

While quantitation is the norm in PET, it is not widely available yet in SPECT. This work's aim was to calibrate a commercially available SPECT/CT system to perform quantitative SPECT. Counting sensitivity, dead-time (DT) constant and partial volume effect (PVE) of the system were assessed. A dual-head Siemens SymbiaT6 SPECT/CT camera equipped with low energy high-resolution collimators was studied. {sup 99m}Tc was the radioisotope of interest because of its wide usage in nuclear medicine. First, point source acquisitions were performed (activity: 30–990MBq). Further acquisitions were then performed with a uniform Jaszczak phantom filled with water at high activity (25–5000MBq). PVE was studied using 6 hot spheres (diameters: 9.9–31.2 mm) filled with {sup 99m}Tc (2.8MBq/cc) in the Jaszczak phantom, which was: (1) empty, (2) water-filled and (3) water-filled with low activity (0.1MBq/cc). The data was reconstructed with the Siemens's Flash3D iterative algorithm with 4 subsets and 8 iterations, attenuation-correction (AC) and scatter-correction (SC). DT modelling was based on the total spectrum counting rate. Sensitivity was assessed using AC-SC reconstructed SPECT data. Sensitivity and DT for the sources were 99.51±1.46cps/MBq and 0.60±0.04µs. For the phantom, sensitivity and DT were 109.9±2.3cps/MBq and 0.62±0.13µs. The recovery-coefficient varied from 5% for the 9.9mm, to 80% for the 31.2mm spheres. With our calibration methods, both sensitivity and DT constant of the SPECT camera had little dependence on the object geometry and attenuation. For small objects of known size, recovery-coefficient can be applied to correct PVE. Clinical quantitative SPECT appears to be possible and has many potential applications.

07 ISOTOPE AND RADIATION SOURCES↗

Mach Stability Improvements Using an Existing Second Throat Capability at the National Transonic Facility

Recent data quality improvements at the National Transonic Facility have an intended goal of reducing the Mach number variation in a data point to within plus or minus 0.0005, with the ultimate goal of reducing the data repeatability of the drag coefficient for full-span subsonic transport models at transonic speeds to within half a drag count. This paper will discuss the Mach stability improvements achieved through the use of an existing second throat capability at the NTF to create a minimum area at the end of the test section. These improvements were demonstrated using both the NASA Common Research Model and the NTF Pathfinder-I model in recent experiments. Sonic conditions at the throat were verified using sidewall static pressure data. The Mach variation levels from both experiments in the baseline tunnel configuration and the choked tunnel configuration will be presented and the correlation between Mach number and drag will also be examined. Finally, a brief discussion is given on the consequences of using the second throat in its location at the end of the test section.

Chan, David T.↗

DETERMINING NEUTRON STAR MASSES AND RADII USING ENERGY-RESOLVED WAVEFORMS OF X-RAY BURST OSCILLATIONS

Simultaneous, precise measurements of the mass M and radius R of neutron stars can yield uniquely valuable information about the still uncertain properties of cold matter at several times the density of nuclear matter. One method that could be used to measure M and R is to analyze the energy-dependent waveforms of the X-ray flux oscillations seen during some thermonuclear bursts from some neutron stars. These oscillations are thought to be produced by X-ray emission from hotter regions on the surface of the star that are rotating at or near the spin frequency of the star. Here we explore how well M and R could be determined by generating and analyzing, using Bayesian techniques, synthetic energy-resolved X-ray data that we produce assuming a future space mission having 2-30 keV energy coverage and an effective area of 10 m{sup 2}, such as the proposed Large Observatory for X-Ray Timing or Advanced X-Ray Timing Array missions. We find that waveforms from hot spots within 10° of the rotation equator usually constrain both M and R with an uncertainty of about 10%, if there are 10{sup 6} total counts from the spot, whereas waveforms from spots within 20° of the rotation pole provide no useful constraints. The constraints we report can usually be achieved even if the burst oscillations vary with time and data from multiple bursts must be used to obtain 10{sup 6} counts from the hot spot. This is therefore a promising method to constrain M and R tightly enough to discriminate strongly between competing models of cold, high-density matter.

79 ASTRONOMY AND ASTROPHYSICS↗

Uncovering a CF 3 Effect on X‐ray Absorption Energies of [Cu(CF 3 ) 4 ] − and Related Copper Compounds by Using Resonant Diffraction Anomalous Fine Structure (DAFS) Measurements**

Abstract Understanding the electronic structures of high‐valent metal complexes aids the advancement of metal‐catalyzed cross coupling methodologies. A prototypical complex with formally high valency is [Cu(CF 3 ) 4 ] − (1), which has a formal Cu(III) oxidation state but whose physical analysis has led some to a Cu(I) assignment in an inverted ligand field model. Recent examinations of1by X‐ray spectroscopies have led previous authors to contradictory conclusions, motivating the re‐examination of its X‐ray absorption profile here by a complementary method, resonant diffraction anomalous fine structure (DAFS). From analysis of DAFS measurements for a series of seven mononuclear Cu complexes including1, here it is shown that there is a systematic trifluoromethyl effect on X‐ray absorption that blue shifts the resonant Cu K‐edge energy by 2–3 eV per CF 3 , completely accounting for observed changes in DAFS profiles between formally Cu(III) complexes like1and formally Cu(I) complexes like (Ph 3 P) 3 CuCF 3 (3). Thus, in agreement with the inverted ligand field model, the data presented herein imply that1is best described as containing a Cu(I) ion with d n count approaching 10.

Chemistry↗

High sensitivity measurement of femtogram-level 238 Pu by thermal ionization mass spectrometry with correction of background 238 U

Low-concentration plutonium isotopic measurements provide a valuable fingerprint to identify possible material origins in the context of environmental contamination monitoring, environmental tracing, nuclear safeguards, nuclear forensics, and treaty monitoring. Thermal ionization mass spectrometry (TIMS) has long been recognized as one of the most sensitive techniques for plutonium isotopic measurement, but has not generally been utilized for 238 Pu determination, especially at low concentrations, due to an isobaric interference from 238 U, prevalent as background. Here, this work demonstrates a new analytical technique for correction of background 238 U from the 238 Pu counts collected during a TIMS analysis. The technique takes advantage of the higher ionization temperature of U relative to Pu and uses a 235 U tracer added after plutonium purification chemistry for 238 U semi-quantitative determination. This technique has been successfully applied to the determination of 238 Pu concentration and the 238 Pu/ 239 Pu ratio in sample types including single-isotope standards, isotopic certified reference materials, matrix-containing environmental reference materials, and simulated nuclear detonation debris. The results have been directly compared on a sample-by-sample basis to alpha spectrometry results. The detection limit by this new technique is 0.23 fg 238 Pu, which was previously unachievable by mass spectrometry and is possible in around 1 h of analysis time post-chemistry compared to weeks of required counting time by alpha spectrometry (at the same atom amount). We also present original, high precision data for Pu isotope concentrations in IAEA-384, Fangataufa Sediment, including 242 Pu results for the first time. The new technique allows measurement of a key isotope, 238 Pu, that was previously not measured in small environmental or nuclear forensics collections.

238Pu↗

Antimicrobial properties of nanostructured surfaces – demonstrating the need for a standard testing methodology

Bioinspired nanostructured materials that exhibit antimicrobial properties are being synthesized and tested at increasing rates for use in healthcare, manufacturing processes, and diagnostics. Although progress has been made in improving and understanding their bactericidal activity, arguably, the biggest problem currently in the field is the lack of a standard testing methodology that allows for optimal characterization and better comparison of emerging nanostructures. In this work, we examine two forms of nanostructured silicon that vary in their ability to kill certain bacterial species due to different physical mechanisms and derive guidelines for the comparative testing. We perform a comprehensive evaluation of methodologies used extensively in the field (e.g., colony counting and live dead analysis) and the novel application of high-throughput flow cytometry. The data reveal how the techniques are complementary but not always directly equivalent or correlative. Therefore, comparison of results obtained using different methodologies on different materials can be grossly misleading. We report significant variations in bactericidal efficiencies depending on experimental environments (medium type, etc.) and methodologies employed. In addition, we demonstrate how cytometry is yet another powerful complementary tool that can aid the mechanistic understanding of antimicrobial activities of rough surfaces. Besides standardization for comparison, ultimately, evaluation methods need to consider anticipated applications. Then and only then can the true potential (or limitation) of a novel material be determined for its suitability for advancement in a particular field of use.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Characterization of Thermal Cross-talk in a {gamma}-ray Microcalorimeter Array

We present experimental data describing cross-talk within an array of gamma-ray microcalorimeters during gamma-ray irradiation. The microcalorimeters consist of Mo/Cu transition-edge sensors (TESs) with attached Sn absorbers. We observe both thermal and electrical cross-talk with peak cross-talk amplitudes as large as 0.4%. We have developed an analytical model for thermal cross-talk and make a preliminary comparison to data. Cross-talk must be understood and minimized for high resolution spectroscopy at high input count rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

aCORN: An experiment to measure the electron-antineutrino correlation coefficient in free neutron decay

Here, we describe an apparatus used to measure the electron-antineutrino angular correlation coefficient in free neutron decay. This apparatus employs a novel measurement technique in which the angular correlation is converted into a proton time-of-flight asymmetry that is counted directly, avoiding the need for proton spectroscopy. We present details of the method, apparatus, detectors, data acquisition, and data reduction scheme, along with a discussion of the important systematic effects.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis of the low-energy electron-recoil spectrum of the CDMS experiment

We report on the analysis of the low-energy electron-recoil spectrum from the CDMS II experiment using data with an exposure of 443.2 kg-days. The analysis provides details on the observed counting rate and possible background sources in the energy range of 2-8.5 keV. We find no significant excess of a peaked contribution to the total counting rate above the background model, and compare this observation to the recent DAMA results. In the framework of a conversion of a dark matter particle into electromagnetic energy, our 90% confidence level upper limit of 0.246 events/kg/day at 3.15 keV is lower than the total rate above background observed by DAMA. In absence of any specific particle physics model to provide the scaling in cross section between NaI and Ge, we assume a Z{sup 2} scaling. With this assumption the observed rate in DAMA remains higher than the upper limit in CDMS. Under the conservative assumption that the modulation amplitude is 6% of the total rate we obtain upper limits on the modulation amplitude a factor of {approx}2 lower than observed by DAMA, constraining some possible interpretations of this modulation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cooling Strategies for an Electric Motor with Additively Manufactured Hollow Conductors and Distributed Power Electronics Integrated with Heat Pipes

This paper discusses design tradeoffs and thermal modeling explored in cooling strategies for an aircraft propulsion electric motor with additively manufactured coils and distributed power electronics integrated with heat pipes. Design tradeoffs include heat pipe Qmax performance related to inclination, condenser configuration, coolant type, coolant flow path complexity, and ease of access to modular power electronics. Three cooling strategies were selected and realized into CAD models. These models were further evaluated using 3D thermal FEA and optimization tools to explore cooling geometry details that include fin thickness, spacing and count with the objective to minimize fin mass under a set of constraints. Lastly, motorette test data is presented comparing air versus liquid cooling of heat pipes.

additive manufacturing↗

Analytical Modeling of Cache Behavior for Affine Programs

Modern optimizing compiler design integrates program transformation strategies aimed at reducing data movement to/from main memory by exploiting the data cache hierarchy. But in reality, the effect of these transformations on the actual cache miss count is ignored in compilers due to the lack of precise compile-time models of misses for hierarchical caches. The current state of practice for cache miss analysis is based on accurate simulation. However, simulation requires time proportional to the dataset/problem size as well as the number of distinct cache configurations of interest to be evaluated. This paper takes a fundamentally different approach, made possible by focusing on polyhedral programs with static control flow: instead of relying on costly simulation, this paper develops the first closed-form solution for exact modeling of misses in a set-associative cache hierarchy. It enabling simulation-less selection of program transformations at compile-time to optimize cache misses. A push-button tool implementing the approach is developed and used for extensive validation of the complete framework.

affine programs, cache modeling, set associativity↗

Analysis of prescribed fire days in climate model output

This code analyzes openly available, downscaled climate model output and counts days in a year that are available to conduct prescribed fire based on meteorological prescription data obtained from US land management agencies.

Jonko, Alexandra↗

The effect of enrofloxacin on enteric Escherichia coli : Fitting a mathematical model to in vivo data

Antimicrobial drugs administered systemically may cause the emergence and dissemination of antimicrobial resistance among enteric bacteria. To develop logical, research-based recommendations for food animal veterinarians, we must understand how to maximize antimicrobial drug efficacy while minimizing risk of antimicrobial resistance. Our objective is to evaluate the effect of two approved dosing regimens of enrofloxacin (a single high dose or three low doses) on Escherichia coli in cattle. We look specifically at bacteria above and below the epidemiological cutoff (ECOFF), above which the bacteria are likely to have an acquired or mutational resistance to enrofloxacin. We developed a differential equation model for the antimicrobial drug concentrations in plasma and colon, and bacteria populations in the feces. The model was fit to animal data of drug concentrations in the plasma and colon obtained using ultrafiltration probes. Fecal E. coli counts and minimum inhibitory concentrations were measured for the week after receiving the antimicrobial drug. We predict that the antimicrobial susceptibility of the bacteria above the ECOFF pre-treatment strongly affects the composition of the bacteria following treatment. Faster removal of the antimicrobial drugs from the colon throughout the study leads to improved clearance of bacteria above the ECOFF in the low dose regimen. If we assume a fitness cost is associated with bacteria above the ECOFF, the increased fitness costs leads to reduction of bacteria above the ECOFF in the low dose study. These results suggest the initial E. coli susceptibility is a strong indicator of how steers respond to antimicrobial drug treatment.

59 BASIC BIOLOGICAL SCIENCES↗