Magnetic fluctuation profile measurement using optics of motional Stark effect diagnostics in JT-60U

Motional Stark effect (MSE) diagnostics in JT-60U works as polarimeter to measure the pitch angle of magnetic field as well as beam-emission-spectroscopy (BES) monochromator simultaneously at 30 spatial channels. Fluctuation in the BES signal using MSE optics (MSE/BES) contains fluctuations in not only the density but also the pitch angle (or the magnetic field). Correlation analysis of the magnetic fluctuation between two spatial channels is applied to high-beta plasma with a magnetohydrodynamic activity at frequency of about 0.9 kHz. It has been found that the magnetic fluctuation measured by the MSE/BES is spatially localized near the magnetic flux surface having safety factor and that the phase of the fluctuation is inverted at about the surface, suggesting magnetic island structure by tearing mode. The phase of the magnetic fluctuation measured by the MSE/BES at outside of the q=2 surface is consistent with that by the pickup coil placed outside the plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A novel backscatter focus diagnostic for the TRIDENT 200 TW laser

Here we present the first direct focal spot images and analysis of an ultrahigh intensity short-pulse laser focus (>5x10{sup 19} W/cm{sup 2}) on target. Such a focal spot characterization is typically done previous to the shot with a low-power alignment beam using equivalent plane imaging techniques. The resulting intensity of the shot is then inferred from these results. We report on the development of a backscatter focus diagnostic, which enables imaging of the on-target full-power focal spot.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnostics for the biased electrode experiment on NSTX

A linear array of four small biased electrodes was installed in NSTX in an attempt to control the width of the scrape-off layer by creating a strong local poloidal electric field. The set of electrodes was separated poloidally by a 1 cm gap between electrodes and were located slightly below the midplane of NSTX, 1 cm behind the rf antenna, and oriented so that each electrode is facing approximately normal to the magnetic field. Each electrode can be independently biased to {+-}100 V. Present power supplies limit the current on two electrodes to 30 A and the other two to 10 A each. The effect of local biasing was measured with a set of Langmuir probes placed between the electrodes and another set extending radially outward from the electrodes, and also by the gas puff imaging diagnostic located 1 m away along the magnetic field lines intersecting the electrodes. Two fast cameras were also aimed directly at the electrode array. The hardware and controls of the biasing experiment will be presented and the initial effects on local plasma parameters will be discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Micro-Particles as Electrostatic Probes for Plasma Sheath Diagnostic

An interesting aspect in the research of complex (dusty) plasmas is the experimental study of the interaction of micro-particles of different sizes with the surrounding plasma for diagnostic purpose. In the plasma micro-disperse particles are negatively charged and confined in the sheath. The particles are trapped by an equilibrium of gravity, electric field force and ion drag force. From the behavior, local electric fields can be determined, e.g. particles are used as electrostatic probes. In combination with additional measurements of the plasma parameters with Langmuir probes and thermal probes as well as by comparison with an analytical sheath model, the structure of the sheath can be described. In the present work we focus on the behavior of micro-particles of different sizes and several plasma parameters e.g. the gas pressure and the rf-power.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Whispering Gallery Mode Spectroscopy as a Diagnostic for Dusty Plasmas

Whispering-gallery-mode spectroscopy is being assessed as a diagnostic method for the characterisation of size and chemical composition of spherical particles levitated in a plasma. With a pulsed laser whispering gallery modes (cavity resonances) are excited in individual microspheres leading to enhanced Raman scattering or fluorescence at characteristic wavelengths. This method can be used to gain specific information from the particle surface and is thus of great interest for the characterisation of layers deposited on microparticles, e.g. in molecular plasmas. We present investigations of different microparticles in air and results from fluorescent particles levitated in an Argon rf plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Low temperature plasma diagnostics with tunable synchrotron vacuum ultraviolet photoionization mass spectrometry

Plasma-based technology is of great importance for a range of industrial applications. However, due to the complexity of gas-phase and surface chemical reactions, the underlying plasma chemistry is still poorly understood, leading to a growing demand for experimental setups on plasma diagnostics. In this paper, we report an apparatus that combines tunable synchrotron vacuum ultraviolet (VUV) photoionization with molecular-beam mass spectrometry for detecting ionic and neutral species formed in the processes of plasma discharge. The products including reactive intermediates such as enols can be identified unambiguously with the measurements of photoionization mass spectrometry (PIMS) and photoionization efficiency spectra. The tunable VUV PIMS has been proven as an ideal and sensitive tool for a comprehensive understanding of plasma chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of the sensitivity and fading characteristics of an image plate system for x-ray diagnostics

Image plates (IPs) are a reusable recording media capable of detecting ionizing radiation, used to diagnose x-ray emission from laser-plasma experiments. Due to their superior performance characteristics in x-ray applications [C. C. Bradford, W. W. Peppler, and J. T. Dobbins III, Med. Phys. 26, 27 (1999) and J. Digit. Imaging. 12, 54 (1999)], the Fuji Biological Analysis System (BAS) IPs are fielded on x-ray diagnostics for the HELEN laser by the Plasma Physics Department at AWE. The sensitivities of the Fuji BAS IPs have been absolutely calibrated for absolute measurements of x-ray intensity in the energy range of 0-100 keV. In addition, the Fuji BAS IP fading as a function of time was investigated. We report on the characterization of three Fuji BAS IP responses to x-rays using a radioactive source, and discrete x-ray line energies generated by the Excalibur soft x-ray facility and the Defense Radiological Standards Centre filter-fluorescer hard x-ray system at AWE.

07 ISOTOPE AND RADIATION SOURCES↗

On the Use of Spectral Lines Emitted by Carbon Ions for Plasma Diagnostics in Magnetic Fusion Devices

Profiles of the n = 5-6 ({lambda} = 4658 A) and n = 6-7(7726 A) lines emitted by Li-like carbon C{sup +3} ions have been computed for plasma conditions of tokamak and stellarator divertors (N{sub e} = 10{sup 19}-10{sup 21} m{sup -3}, Te = 1-10 eV). The broadening and profiles of these lines are proposed to be used for plasma diagnostic purposes in particular to crosscheck the validity of the plasma parameters determined from the CIV line intensities measured in JT-60U tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Localized measurement of short wavelength plasma fluctuations with the DIII-D phase contrast imaging diagnostic

A novel rotating mask system has been designed and implemented on the DIII-D phase contrast imaging (PCI) diagnostic to produce the first spatially localized PCI measurements of a tokamak plasma. The localization technique makes use of the variation in the magnetic field component perpendicular to the viewing chord as a function of chord height. This new capability provides measurements in the range of 2<k<30 cm{sup -1}, 10 kHz<f<10 MHz, and 0.7<r/a<1. This technique provides a spatial resolution of 10 cm at k=15 cm{sup -1} and can realistically provide measurements at a rate of 10 profiles/s. Calibration measurements show accurate characterization of the system transfer function making feasible a time dependent analysis that results in improved localization. Initial measurements show turbulence to peak near the plasma edge. This upgrade is part of a broader program to operate the DIII-D PCI at wave numbers up to 40 cm{sup -1} to probe electron scale turbulence in the plasma core.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Longitudinal Diagnostics of Short Bunches at FLASH

Novel acceleration concepts such as laser- or beam-driven plasma acceleration require advanced diagnostic techniques to characterize and monitor the beam. A particular challenge is to measure bunch lengths of the order of 10 femtoseconds. Several methods are currently explored at the free-electron laser FLASH at DESY/Hamburg and will be discussed it this paper, such as electro-optical sampling, streaking bunches with a transversely deflecting cavity, and -most recently implemented at FLASH--the optical-replica synthesizer, a laser-based technique promising a time resolution of a few femtoseconds.

43 PARTICLE ACCELERATORS↗

Fast optical spectrometer for the charge exchange diagnostic on RFX-mod

A new fast visible spectrometer built for the charge exchange diagnostic system of the RFX-mod Reversed Field pinch experiment is described. The optical mounting is of the Littrow type. The spectral resolution is defined by a 3000 grooves/mm, 180x143 mm{sup 2} wide reflection grating, and a focal length of 400 mm. The collimating optics is based on a commercial high quality f/2.8 telephoto lens, so that the input fibers can be vertically stacked without space in between. The detector is a two-dimensional charge coupled device back-illuminated sensor to ensure high quantum efficiency. Thus the spectrometer combines high speed, high spectral resolution, and excellent imaging quality.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnostic development in precise opacity measurement of radiatively heated Al plasma on Shenguang II laser facility

Simultaneous measurements of the self-emission spectrum, the backlighting source spectrum, and the transmission spectrum in one shot, which reduce the experimental uncertainties from shot-to-shot fluctuation, are essential for precise opacity experiments. In order to achieve precise absorption spectrum of Al plasmas, a special half sample sandwich target was designed and short backlighter was used to provide time- and space-resolving diagnostics on the Shenguang II high power laser facility. In the measurement, a cylindrical cavity with CH foam baffles was used to provide a clean x-ray radiation environment for sample heating. The x-ray source spectrum, the transmission spectrum, and the self-emission spectrum of the soft x-ray heated Al sample were recorded in one shot with a penta-erythritol tetrakis (hydroxymethy) methane C(CH{sub 2}OH){sub 4} (PET) crystal spectrometer by using the point-projection method. Experimental results have been compared with the calculation results of a detailed level accounting opacity code.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser-Aided Diagnostics of Atoms and Particulates in Magnetron Sputtering Plasmas

Laser-aided diagnostic technique is introduced as an advanced and valuable technique to evaluate the properties of plasma. This technique is an expensive and sophisticated technique which requires researchers to have a basic knowledge in optical spectroscopy. In the present paper, we will generally introduce the experimental work using laser-induced fluorescence (LIF) and laser light scattering (LLS) techniques. The LIF was used to evaluate the spatial distribution of Cu atoms in magnetron sputtering plasma. The change in the spatial distribution was studied as a function of discharge power. On the other hand, the LLS was used to evaluate the generation of Cu particulates in high-pressure magnetron sputtering plasma. The temporal evolution of Cu particulates in the gas phase of sputtering plasma was visualized successfully.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On-Target Contrast Diagnostic via Specular Reflectivity Measurement

High-power laser contrast is challenging to measure, especially in the real target irradiation conditions. We present a convenient and relatively simple contrast diagnostic technique based on the measurement of target specular reflectivity at full laser power. The reflectivity remains high even at intensities above 10{sup 19} W/cm{sup 2} in the case of a high-contrast prepulse-free laser. On the contrary, the specular reflectivity drops in the case of lower contrast, due to the beam break-up and increased absorption caused by the preformed plasma. The technique was demonstrated using three different laser systems with several contrast conditions: Astra (CLF, RAL), TiS laser at APRI, GIST, and J-KAREN (APRC, JAEA).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnostic based modeling for determining absolute atomic oxygen densities in atmospheric pressure helium-oxygen plasmas

Absolute atomic oxygen ground state densities in a radio-frequency driven atmospheric pressure plasma jet, operated in a helium-oxygen mixture, are determined using diagnostic based modeling. One-dimensional numerical simulations of the electron dynamics are combined with time integrated optical emission spectroscopy. The population dynamics of the upper O 3p {sup 3}P ({lambda}=844 nm) atomic oxygen state is governed by direct electron impact excitation, dissociative excitation, radiation losses, and collisional induced quenching. Absolute values for atomic oxygen densities are obtained through comparison with the upper Ar 2p{sub 1} ({lambda}=750.4 nm) state. Results for spatial profiles and power variations are presented and show excellent quantitative agreement with independent two-photon laser-induced fluorescence measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ion flux mapping in an inertial-electrostatic confinement device using a chordwire diagnostic

Theoretical study of ion microchannels that form in an inertial-electrostatic confinement (IEC) device has helped understand the behavior of ions of various energies within a microchannel and has also predicted that smaller grids produce a more converged core. However, such theoretical work has many limitations that make experimental work indispensable. In the present paper the experimental measurements of ion flow patterns into the cathode grid and their consequences (using a 'chordwire' diagnostic that intercepts ions streaming into the IEC core) are reported. Experimental measurements also have quantified the interruption of the ion flow due to the adverse influence of the high voltage stalk. In addition, the chordwire arrangement can be used to study the radiation damage of materials.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Use of Fast Ion D-Alpha diagnostics for understanding ICRF effects

Combined neutral beam injection and fast wave heating at cyclotron harmonics accelerate deuterium fast ions in the National Spherical Torus Experiment (NSTX) and in the DIII-D tokamak. Acceleration above the injected energy is evident in fast-ion D-alpha (FIDA) and volume-average neutron data. The FIDA diagnostic measures spatial profiles of the accelerated fast ions. In DIII-D, the acceleration is at a 4th or 5th cyclotron harmonic; the maximum enhancement in the high-energy FIDA signal is 8-10 cm beyond the resonance layer. In NSTX, acceleration is observed at five harmonics (7-11) simultaneously; overall, the profile of accelerated fast ions is much broader than in DIII-D. The energy distribution predicted by the CQL3D Fokker-Planck code agrees fairly well with measurements in DIII-D. However, the predicted profiles differ from experiment, presumably because the current version of CQL3D uses a zero-banana-width model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental validation of a diagnostic technique for tuning the fourth shock timing on National Ignition Facility

Capsule implosions on the National Ignition Facility (NIF) [Lindl et al., Phys. Plasmas 11, 339 (2004)] will be driven with a carefully tailored sequence of four shock waves that must be timed to very high precision in order to keep the fuel on a low adiabat. The Hohlraum conditions present during the first three shocks allow for a very accurate and direct diagnosis of the strength and timing of each individual shock by velocity interferometry. Experimental validation of this diagnostic technique on the OMEGA Laser Facility [Boehly et al., Opt. Commun. 133, 495 (1997)] has been reported in [Boehly et al., Phys. Plasmas 16, 056302 (2009)]. The Hohlraum environment present during the launch and propagation of the final shock, by contrast, is much more severe and will not permit diagnosis by the same technique. A new, closely related technique has been proposed for measuring and tuning the strength and timing of the fourth shock. Experiments to test this technique under NIF-relevant conditions have also been performed on OMEGA. The result of these experiments and a comparison to numerical simulations is presented, validating this concept.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗