Search NASA⌕ Search

SEARCH · Search NASA

Results for “diffraction in time”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Preferred orientation of calcium aluminosilicate hydrate compacts: Implications for creep and indentation

Nano/micro-indentation has been extensively used to examine elastic properties and creep of cement-based materials. However, there have been inconsistencies in the measured elastic moduli and debate on the creep mechanism of calcium (alumino) silicate hydrates (C-(A-)S-H). To bring new insights, we examined the deviatoric stress-induced preferred orientation of calcium aluminosilicate hydrate (C-A-S-H), portlandite, and ettringite compacts, using synchrotron-based X-ray diffraction. Intense preferred orientations were observed in C-A-S-H compacts, and the c-axis of unit cells is highly aligned with the compression direction; weaker c-axis related fiber-type texture formed in portlandite and ettringite. Higher humidity, greater compacting pressure, and/or increased duration of the pressure intensified the C-A-S-H preferred orientation, which is facilitated by gel-pore water lubrication. This pressure-induced time-dependent preferential re-orientation of crystallites can contribute to the creep of cement-based materials, and it may cause overrepresentation of the soft c-axis of C-(A-)S-H unit-cell in nanoindentation experiments and underestimation of Young's modulus.

36 MATERIALS SCIENCE↗

POWTEX visits POWGEN

The high-intensity time-of-flight (TOF) neutron diffractometer POWTEX for powder and texture analysis is currently being built prior to operation in the eastern guide hall of the research reactor FRM II at Garching close to Munich, Germany. Because of the world-wide 3 He crisis in 2009, the authors promptly initiated the development of 3 He-free detector alternatives that are tailor-made for the requirements of large-area diffractometers. Herein is reported the 2017 enterprise to operate one mounting unit of the final POWTEX detector on the neutron powder diffractometer POWGEN at the Spallation Neutron Source located at Oak Ridge National Laboratory, USA. As a result, presented here are the first angular- and wavelength-dependent data from the POWTEX detector, unfortunately damaged by a 50 g shock but still operating, as well as the efforts made both to characterize the transport damage and to successfully recalibrate the voxel positions in order to yield nonetheless reliable measurements. Also described is the current data reduction process using the PowderReduceP2D algorithm implemented in Mantid [Arnold et al. (2014). Nucl. Instrum. Methods Phys. Res. A , 764 , 156–166]. The final part of the data treatment chain, namely a novel multi-dimensional refinement using a modified version of the GSAS-II software suite [Toby & Von Dreele (2013). J. Appl. Cryst. 46 , 544–549], is compared with a standard data treatment of the same event data conventionally reduced as TOF diffraction patterns and refined with the unmodified version of GSAS-II . This involves both determining the instrumental resolution parameters using POWGEN's powdered diamond standard sample and the refinement of a friendly-user sample, BaZn(NCN) 2 . Although each structural parameter on its own looks similar upon comparing the conventional (1D) and multi-dimensional (2D) treatments, also in terms of precision, a closer view shows small but possibly significant differences. For example, the somewhat suspicious proximity of the a and b lattice parameters of BaZn(NCN) 2 crystallizing in Pbca as resulting from the 1D refinement (0.008 Å) is five times less pronounced in the 2D refinement (0.038 Å). Similar features are found when comparing bond lengths and bond angles, e.g. the two N—C—N units are less differently bent in the 1D results (173 and 175°) than in the 2D results (167 and 173°). The results are of importance not only for POWTEX but also for other neutron TOF diffractometers with large-area detectors, like POWGEN at the SNS or the future DREAM beamline at the European Spallation Source.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Kinetic protein crystallography: a tool to watch proteins in action

Many proteins function in the crystalline state, making crystallography a tool that, beside structure, can address mechanism. By initiating biological turnover in the crystal, transient structural species form, which may be filmed 'on the fly' by Laue diffraction or captured by trapping methods. These strategies are jointly referred to as 'kinetic crystallography'. In this article, we review the general concepts of kinetic crystallography in the context of the conformational energy landscape of a protein. Whereas Laue diffraction is best suited to the investigation of cyclic, ultra-fast and light-triggered reactions, trapping approaches, on the other hand, are applicable to a wider range of biological systems but require care to avoid artefacts. Complementary methods - mainly UV/visible single-crystal spectroscopy - have proven essential to design, interpret and validate kinetic crystallography experiments. Achievements in the field as well as remaining puzzling questions are considered through the examination of recently published work: real-time-resolved crystallography of dimeric haemoglobin based on pump-probe Laue diffraction, temperature-trapping crystallography of acetylcholinesterase based on photo- and radio-induced ligand cleavage, and lattice-trapping crystallography of superoxide reductase based on product soaking and the combined use of X-ray diffraction and Raman spectroscopy.

59 BASIC BIOLOGICAL SCIENCES↗

Grain Boundary Plane Measurement Using Transmission Electron Microscopy Automated Crystallographic Orientation Mapping for Atom Probe Tomography Specimens

Abstract Grain boundaries are critical in determining the properties of materials, including mechanical stability, conductivity, and corrosion resistance. The specific properties of materials depend not only on the misorientation of the crystals, the three most commonly characterized parameters, but also on the angle of the grain boundary plane between the two crystals, the final two parameters in the five-parameter macroscopic description of the grain boundary. The method presented here allows for the direct measurement of all five parameters of the grain boundary in a transmission electron microscopy specimen of various morphologies. This is especially applicable to atom probe specimens, where only a single-tilt axis is generally available, allowing the crystallographic description to be matched to the detailed chemical data available in the atom probe tomography. This method provides a platform for efficient grain boundary analysis in unique samples, saving operator time and allowing for ease of acquisition and interpretation in comparison with traditional electron diffraction methods.

Materials Science↗

Subdiffraction field localisation in the scattering of femtosecond laser radiation by a dielectric microsphere

The time dynamics of the optical field was theoretically considered in the near-field diffraction zone in the scattering of a femtosecond laser pulse by a transparent spherical microparticle. The spatial region of field focusing by the particle (the 'photonic jet' zone) was investigated; the evolution of the jet shape and the peak intensity in this region were analysed. For the first time it was determined that an extremely tight optical field localisation to a subdiffraction size is possible at a certain (resonance) temporal stage of photonic jet development. (radiation scattering)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A mechanistic study on the synthesis of β-Sialon whiskers from coal fly ash

Graphical abstract: The appearance of bead-like whiskers indicated that the growth mechanism of the β-Sialon whiskers was different from the conventional one, in which a chain of droplets were formed and then consumed to participate in the formation of the whiskers. - Highlights: • β-Sialon whiskers were synthesized using waste fly ash by carbothemal reduction reaction under nitrogen atmosphere. • Rod-like β-Sialon whiskers with a diameter of 100–500 nm were formed. • Bead-like whiskers as intermediate morphology of the growing β-Sialon whiskers were found with increasing sintering time. • The growth mechanism of β-Sialon whiskers was different from the conventional VLS mechanism. • A chain of droplets were formed and participated in the formation of the whiskers. - Abstract: β-Sialon whiskers were produced at 1420 °C through carbothemal reduction reaction under nitrogen atmosphere using fly ash from coal-fired power plants. The effects of sintering time on the phase formation and morphology of the products were investigated by X-ray diffraction (XRD), scanning electron microscope (SEM) and energy dispersive spectrometer (EDS) techniques. Rod-like β-Sialon whiskers with the diameter of 100–500 nm were successfully formed. With increasing sintering time, bead-like morphology during the growth process of the whiskers was found, and growth mechanism of β-Sialon whiskers was also discussed in detail. The growth mechanism proposed in this study was different from the conventional vapor–liquid–solid (VLS) mechanism.

36 MATERIALS SCIENCE↗

An inorganic coating and flexible regulating in situ of stent endothelialization by the controllable ion releasing

Highlights: • The Cu/Ti film with regulating the various responses of ECs and SMCs has been prepared. • The hemocompatibility could be adjusted via the ratio of Cu/Ti. • The volume and velocity of copper ion released from film was designed via the preparation processing. - Abstract: A facile approach to fabricate an inorganic coating with favorable blood compatibility and accelerating endothelialization is reported. The inorganic coating with various ratios of Cu and Ti atom are prepared on 316 L stainless steel by physical vapor deposition method. The phase composition and structure as well as the element concentration of the coating are investigated by X-ray diffraction and X-photoelectron energy spectrum. The hemolysis ratio, clotting time and platelet adhesion are utilized to characterize the materials’ hemocompatibility, the copper ion releasing was also investigated via immersing test. The result indicates that copper-titanium coating show good compatibility; however, as the ratio of Cu to Ti increases, the hemolysis ratio also increases. The endothelialization degree was accelerated owing to maintain less than 7.0 μg/ml of Cu{sup 2+} concentrate, and endothelial cells proliferate more readily than smooth muscle cells. The results demonstrate that this degradable copper-containing coating is suitable as a new surface modification for vascular stents.

36 MATERIALS SCIENCE↗

A new setup for the investigation of swift heavy ion induced particle emission and surface modifications

The irradiation with fast ions with kinetic energies of >10 MeV leads to the deposition of a high amount of energy along their trajectory (up to several ten keV/nm). The energy is mainly transferred to the electronic subsystem and induces different secondary processes of excitations, which result in significant material modifications. A new setup to study these ion induced effects on surfaces will be described in this paper. The setup combines a variable irradiation chamber with different techniques of surface characterizations like scanning probe microscopy, time-of-flight secondary ion, and neutral mass spectrometry, as well as low energy electron diffraction under ultra high vacuum conditions, and is mounted at a beamline of the universal linear accelerator (UNILAC) of the GSI facility in Darmstadt, Germany. Here, samples can be irradiated with high-energy ions with a total kinetic energy up to several GeVs under different angles of incidence. Our setup enables the preparation and in situ analysis of different types of sample systems ranging from metals to insulators. Time-of-flight secondary ion mass spectrometry enables us to study the chemical composition of the surface, while scanning probe microscopy allows a detailed view into the local electrical and morphological conditions of the sample surface down to atomic scales. With the new setup, particle emission during irradiation as well as persistent modifications of the surface after irradiation can thus be studied. We present first data obtained with the new setup, including a novel measuring protocol for time-of-flight mass spectrometry with the GSI UNILAC accelerator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-Ray Diffraction of Slag-Based Sodium Salt Waste Forms

Cementitious materials are used to solidify and stabilize aqueous based radioactive waste containing sodium salts. The types and proportions of cementitious ingredients used to treat aqueous radioactive waste streams containing sodium salts depend on the performance objectives for the waste forms and the compositions of the waste streams. Matrix phases can stabilize certain contaminants (co-precipitation, substitution, ion exchange, and / or sorption), influence processing properties, and are responsible for physical properties and durability of the cured waste forms. Consequently, characterization of the matrix (binder) mineralogy (chemical compositions and crystalline / non crystalline structures) is important for predicting contaminant leaching and evolution of the materials as a function of time and changing conditions This report documents sample preparation and x-ray diffraction results for a series of mixtures of sodium salt waste and cementitious binders. The objective of this study was to provide initial phase characterization for the CBP reference case cementitious salt waste form. This information can be used to: 1) generate a base line for the evolution of the waste form as a function of time and conditions, 2) potentially to design new binders based on mineralogy of the binder, 3) understand and predict anion and cation leaching behavior of contaminants of concern, and 4) predict performance of the waste forms for which phase solubility and thermodynamic data are available. Characterization of the mineralogy is also important for understanding the buffering effects that the waste form has on infiltrating water / leachates. More specifically, identification of hydrated phases capable of sequestering anions in the structures and crystallinity of the calcium silicate binder phases were of particular interest. The intent was to use this characterization data as a starting point for more detailed phase characterization using neutron diffraction techniques in addition to quasi-elastic neutron scattering techniques for characterization of water at the ORNL Spallation Neutron Source, Oak Ridge, TN. The initial characterization is complete. Due to extensive substitutions of cations and anions in the layered double hydroxide phases and the very fine intermixing of poorly crystalline hydrated phases in the reference case blend (10 : 45 : 45 cement : slag : fly ash), electron diffraction and transmission electron spectroscopy are recommended as the next step for characterization. In summary, the hydrated mixtures of Type II portland cement, Grade 100 ground granulated blast furnace slag (GGBFS) and carbon burn-out (CBO) Class F Fly ash contained hydrated phase assemblages which were typical of those reported in the literature. Based on x-ray diffraction results, no significant differences were detected in samples cured 2 months and 14 months in sealed containers at ambient indoor temperatures.

36 MATERIALS SCIENCE↗

POWGEN: a third-generation high resolution high-throughput powder diffraction instrument at the Spallation Neutron Source

Powgen represents a departure from previous designs for a time-of-flight powder diffractometer at a spallation neutron source and may be considered a third-generation design. The instrument is optimized for both parametric studies of materials under a wide range of conditions (T, P, H, flowing gases, etc) and ab-initio crystal structure determinations of complex solid-state materials with asymmetric unit-cells of the order {approx}1500 {angstrom}{sup 3}. The geometric design of the instrument allows for all detected scattered neutrons to be focused onto a single diffraction profile yielding high count rate while preserving good resolution {Delta}d/d = 0.0015 at a d = 1 {angstrom}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Construction and development of a time-resolved x-ray magnetic circular dichroism-photoelectron emission microscopy system using femtosecond laser pulses at BL25SU SPring-8

A femtosecond pulsed laser system has been installed at the BL25SU soft x-ray beamline at SPring-8 for time-resolved pump-probe experiments with synchronization of the laser pulses to the circularly polarized x-ray pulses. There are four different apparatuses situated at the beamline; for photoemission spectroscopy, two-dimensional display photoelectron diffraction, x-ray magnetic circular dichroism (XMCD) with electromagnetic coils, and photoelectron emission microscopy (PEEM). All four can be used for time-resolved experiments, and preliminary investigations have been carried out using the PEEM apparatus to observe magnetization dynamics in combination with XMCD. In this article, we describe the details of the stroboscopic pump-probe XMCD-PEEM experiment, and present preliminary data. The repetition rate of the laser pulses is set using a pulse selector to match the single bunches of SPring-8's hybrid filling pattern, which consists of several single bunches and a continuous bunch train. Electrons ejected during the bunch train, which do not provide time-resolved signal, are eliminated by periodically reducing the channel plate voltage using a custom-built power supply. The pulsed laser is used to create 300 ps long magnetic field pulses, which cause magnetic excitations in micron-sized magnetic elements which contain magnetic vortex structures. The observed frequency of the motion is consistent with previously reported observations and simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-Resolved X-ray Emission Spectroscopy and Resonant Inelastic X-ray Scattering Spectroscopy of Laser Irradiated Carbon

The existence of liquid carbon as an intermediate phase preceding the formation of novel carbon materials has been a point of contention for several decades. Experimental observation of such a liquid state requires nonthermal melting of solid carbon materials at various laser fluences and pulse properties. Reflectivity experiments performed in the mid-1980s reached opposing conclusions regarding the metallic or insulating properties of the purported liquid state. Time-resolved X-ray absorption studies showed shortening of C–C bonds and increasing diffraction densities, thought to evidence a liquid or glassy carbon state, respectively. Nevertheless, none of these experiments provided information on the electronic structure of the proposed liquid state. Herein, we report the results of time-resolved resonant inelastic X-ray scattering (RIXS) and time-resolved X-ray emission spectroscopy (XES) studies on amorphous carbon (a-C) and ultrananocrystalline diamond (UNCD) as a function of delay time between the irradiating pulse and X-ray probe. For both a-C and UNCD, we attribute decreases in RIXS or XES signals to transition blocking, relaxation, and finally, ablation. Increased signal at 20 ps following the irradiation of the UNCD is attributed to the probable formation of nanoscale structures in the ablation plume. Further, differences in the amount of signal observed between a-C and UNCD are explained by the difference in sample thickness and, specifically, incomplete melting of the UNCD film. Comparisons to spectral simulations based on MD trajectories at extreme conditions indicate that the carbon state in our experiments is crystalline. Normal mode analysis confirmed that symmetrical bending or stretching of the C–C bonds in the diamond lattice results in XES spectra with small intensity differences. Overall, we observed no evidence of melting to a liquid state, as determined by the lack of changes in the spectral properties for up to 100 ps delays following the melting pulses.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Response to 'Comment on 'Elastic incoherent neutron scattering operating by varying instrumental energy resolution: Principle, simulations, and experiments of the resolution elastic neutron scattering (RENS)'' [Rev. Sci. Instrum. 83, 107101 (2012)]

Recently [S. Magazu et al., Rev. Sci. Instrum. 82, 105115 (2011)] we have proposed a new method for characterizing, by neutron scattering, the dynamical properties of complex material systems, such as, the ones of interest in the biophysical field. This approach called Resolution Elastic Neutron Scattering, in short RENS, is based on the detection of the elastically scattered neutron intensity as a function of the instrumental energy resolution. By experimental, theoretical, and numerical findings, we have pointed out that an inflection point occurs in the elastic intensity when the system relaxation time approaches the instrumental energy resolution time. This approach, differently from quasi-elastic neutron scattering (QENS), gives the chance to evaluate the system relaxation times without using pre-defined models that can be wrong and/or misleading. Here, we reply to a Comment on the above-mentioned main paper in which Wuttke proposes a different approach to evaluate the above-mentioned inflection point; on this regard, it should be noticed that the existence of the inflection point, which is the main topic of our work, is not questioned and that the approach proposed by Wuttke in the Comment, although valid for a class of dynamical processes, is not applicable when different and distinct processes occur simultaneously at different time scale.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Multi-Anode Photomultiplier Tube Based Wavelength-Shifting-Fiber Detector for neutron diffraction

The wavelength-shifting (WLS) fiber scintillator neutron detectors were developed for two time-of-flight (TOF) neutron powder diffractometers (POWGEN, VULCAN) at Spallation Neutron Source (SNS). In a recent module (v3.0), however, there are 32 1-inch-diameter photomultiplier tubes (PMTs) which are bulky and expensive. We built a new detector module (v3.1) based on four multi-anode (MA) PMTs, and tested its performance including detection efficiency, count rate capability, spatial resolution, ghosting properties, and gamma-ray sensitivity. The v3.1 module was compared with two prior v3.0 modules, and 3He tube detectors.

Berry, Kevin D↗

In-line holographic imaging and electron density extraction of ultrafast ionized air filaments

In-line spatial holographic methods are used to image the optical diffraction patterns of ultrafast laser produced plasma filaments in air. Using femtosecond laser pump-probe methods the plasma filament is produced and subsequently probed by a time-delayed probe beam traversing the filament at a right angle. The resulting probe beam image is recorded as a holographic diffraction pattern on a charge coupled device camera as the probe beam is diffracted due to the optical index change caused by the plasma filament. Extraction of the electron density in the filament down to 10{sup 16} cm{sup -3} is obtained by using the Helmholtz wave equation beam propagation model to simulate the data. By varying the pump-probe optical time delay, a plasma electron recombination time of approximately 250 ps is measured and agrees with our rate equation population kinetics model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The crystallinity of calcium phosphate powders influenced by the conditions of neutralized procedure with citric acid additions

Calcium phosphate powders with nano-sized crystallinity were synthesized by neutralization using calcium hydroxide and orthophosphoric acid with the assistance of citric acid. The influence of processing parameters, such as free or additive citric acid, synthetic temperature and ripening time, on the crystallinity of hydroxyapatite were investigated. The results of X-ray diffraction and microstructure observations showed that the crystallinity and morphology of nano-sized hydroxyapatite particles were influenced by the presence or absence of citric acid. It was found that the crystallinities and crystallite sizes of hydroxyapatite powders prepared with the additive citric acid increased with increasing synthetic temperature and ripening time. Especially, the crystallinities of (h k 0) planes were raised and more homogeneously grown particles were obtained with increasing synthetic temperature.

36 MATERIALS SCIENCE↗

Microfocus/Polycapillary-Optic Crystallographic X-Ray System

A system that generates an intense, nearly collimated, nearly monochromatic, small-diameter x-ray beam has been developed for use in macromolecular crystallography. A conventional x-ray system for macromolecular crystallography includes a rotating-anode x-ray source, which is massive (.500 kg), large (approximately 2 by 2 by 1 m), and power-hungry (between 2 and 18 kW). In contrast, the present system generates a beam of the required brightness from a microfocus source, which is small and light enough to be mounted on a laboratory bench, and operates at a power level of only tens of watts. The figure schematically depicts the system as configured for observing x-ray diffraction from a macromolecular crystal. In addition to the microfocus x-ray source, the system includes a polycapillary optic . a monolithic block (typically a bundle of fused glass tubes) that contains thousands of straight or gently curved capillary channels, along which x-rays propagate with multiple reflections. This particular polycapillary optic is configured to act as a collimator; the x-ray beam that emerges from its output face consists of quasi-parallel subbeams with a small angular divergence and a diameter comparable to the size of a crystal to be studied. The gap between the microfocus x-ray source and the input face of the polycapillary optic is chosen consistently with the focal length of the polycapillary optic and the need to maximize the solid angle subtended by the optic in order to maximize the collimated x-ray flux. The spectrum from the source contains a significant component of Cu K (photon energy is 8.08 keV) radiation. The beam is monochromatized (for Cu K ) by a nickel filter 10 m thick. In a test, this system was operated at a power of 40 W (current of 897 A at an accelerating potential of 45 kV), with an anode x-ray spot size of 41+/-2 microns. Also tested, in order to provide a standard for comparison, was a commercial rotating-anode x-ray crystallographic system with a pyrolytic graphite monochromator and a 250-micron pinhole collimator, operating at a power of 3.15 kW (current of 70 mA at an accelerating potential of 45 kV). The flux of collimated Cu K radiation in this system was found to be approximately 16 times that in the rotatinganode system. Data on x-ray diffraction from crystals of tetragonal form of lysozyme (protein) in this system were found to be of high quality and to be reducible by use of standard crystallographic software.

Joy, Marshall↗