Search NASA⌕ Search

SEARCH · Search NASA

Results for “dynamic loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Pick-up ion pressure gradients modulating the solar wind dynamics

Neutral interstellar atoms penetrate deeply into the inner heliosphere before they become ionized by various processes. As ions they are picked-up by the frozen-in magnetic fields and are convected outwards with the solar wind plasma. Thereby the primary plasma flow is mass, momentum, and energy-loaded. The dynamics of the distant multi-constituent solar wind is, however, not solely determined by these loading processes, but is also affected by the wave-mediated pick-up ion pressure gradients derivable from the pick-up ion distribution function. The action of the radial components of these pressures essentially counter balances the decelerating effect of the solar wind momentum loading, diminishing strongly the deceleration of the distant solar wind. Furthermore the latitudinal components of the pick-up ion pressures induce latitudinal forces acting on the multiconstituent solar plasma outflow and inducing nonradial bulk flow components. The enforced nonradial outflow geometry on the upwind hemisphere may partly be responsible for the magnetic flux deficit which was claimed since several years in the PIONEER-10 magnetic flux data.

Fahr, Hans J.↗

Dynamic tensile characterization of a 4330 steel with kolsky bar techniques.

There has been increasing demand to understand the stress-strain response as well as damage and failure mechanisms of materials under impact loading condition. Dynamic tensile characterization has been an efficient approach to acquire satisfactory information of mechanical properties including damage and failure of the materials under investigation. However, in order to obtain valid experimental data, reliable tensile experimental techniques at high strain rates are required. This includes not only precise experimental apparatus but also reliable experimental procedures and comprehensive data interpretation. Kolsky bar, originally developed by Kolsky in 1949 [1] for high-rate compressive characterization of materials, has been extended for dynamic tensile testing since 1960 [2]. In comparison to Kolsky compression bar, the experimental design of Kolsky tension bar has been much more diversified, particularly in producing high speed tensile pulses in the bars. Moreover, instead of directly sandwiching the cylindrical specimen between the bars in Kolsky bar compression bar experiments, the specimen must be firmly attached to the bar ends in Kolsky tensile bar experiments. A common method is to thread a dumbbell specimen into the ends of the incident and transmission bars. The relatively complicated striking and specimen gripping systems in Kolsky tension bar techniques often lead to disturbance in stress wave propagation in the bars, requiring appropriate interpretation of experimental data. In this study, we employed a modified Kolsky tension bar, newly developed at Sandia National Laboratories, Livermore, CA, to explore the dynamic tensile response of a 4330-V steel. The design of the new Kolsky tension bar has been presented at 2010 SEM Annual Conference [3]. Figures 1 and 2 show the actual photograph and schematic of the Kolsky tension bar, respectively. As shown in Fig. 2, the gun barrel is directly connected to the incident bar with a coupler. The cylindrical striker set inside the gun barrel is launched to impact on the end cap that is threaded into the open end of the gun barrel, producing a tension on the gun barrel and the incident bar.

36 MATERIALS SCIENCE↗

Dynamic tensile characterization of a 4330-V steel with kolsky bar techniques.

There has been increasing demand to understand the stress-strain response as well as damage and failure mechanisms of materials under impact loading condition. Dynamic tensile characterization has been an efficient approach to acquire satisfactory information of mechanical properties including damage and failure of the materials under investigation. However, in order to obtain valid experimental data, reliable tensile experimental techniques at high strain rates are required. This includes not only precise experimental apparatus but also reliable experimental procedures and comprehensive data interpretation. Kolsky bar, originally developed by Kolsky in 1949 [1] for high-rate compressive characterization of materials, has been extended for dynamic tensile testing since 1960 [2]. In comparison to Kolsky compression bar, the experimental design of Kolsky tension bar has been much more diversified, particularly in producing high speed tensile pulses in the bars. Moreover, instead of directly sandwiching the cylindrical specimen between the bars in Kolsky bar compression bar experiments, the specimen must be firmly attached to the bar ends in Kolsky tensile bar experiments. A common method is to thread a dumbbell specimen into the ends of the incident and transmission bars. The relatively complicated striking and specimen gripping systems in Kolsky tension bar techniques often lead to disturbance in stress wave propagation in the bars, requiring appropriate interpretation of experimental data. In this study, we employed a modified Kolsky tension bar, newly developed at Sandia National Laboratories, Livermore, CA, to explore the dynamic tensile response of a 4330-V steel. The design of the new Kolsky tension bar has been presented at 2010 SEM Annual Conference [3]. Figures 1 and 2 show the actual photograph and schematic of the Kolsky tension bar, respectively. As shown in Fig. 2, the gun barrel is directly connected to the incident bar with a coupler. The cylindrical striker set inside the gun barrel is launched to impact on the end cap that is threaded into the open end of the gun barrel, producing a tension on the gun barrel and the incident bar.

36 MATERIALS SCIENCE↗

Strength, Fracture Toughness, Fatigue, and Standardization Issues of Free-standing Thermal Barrier Coatings

Strength, fracture toughness and fatigue behavior of free-standing thick thermal barrier coatings of plasma-sprayed ZrO2-8wt % Y2O3 were determined at ambient and elevated temperatures in an attempt to establish a database for design. Strength, in conjunction with deformation (stress-strain behavior), was evaluated in tension (uniaxial and trans-thickness), compression, and uniaxial and biaxial flexure; fracture toughness was determined in various load conditions including mode I, mode II, and mixed modes I and II; fatigue or slow crack growth behavior was estimated in cyclic tension and dynamic flexure loading. Effect of sintering was quantified through approaches using strength, fracture toughness, and modulus (constitutive relations) measurements. Standardization issues on test methodology also was presented with a special regard to material's unique constitutive relations.

Choi, Sung R.↗

Evaluation of low heat conductivity rf cables

New potential applications of superconducting radio-frequency can be envisioned with conduction cooling of the cavities using cryocoolers. In this case, the total heat load to the cryocoolers have to be carefully managed to assure sufficient margin to operate the cavity at an acceptable accelerating gradient. The static and dynamic heat load from rf cables connected to the cavity can be a significant contribution to the total heat load. In this contribution we report the results from measurements of the temperature profile at 1.3 GHz for two low heat conductivity rf cables, as a function of the rf power and with one end of the cable in thermal contact with a liquid helium bath at 4.3 K. A parametric model of the two cables was developed with ANSYS to match the temperature profiles and calculate the heat load at the cold end of the cable.

Cheng, G.↗

Influence of Planetary-Gear Structure on the Load Distribution

A method is proposed for determining the load in the gear engagements of a multiflux planetary gear with flexible carrier jaws. The influence of the design and manufacturing errors of the mechanism on the pliability of its components and the nonuniformity of the load distribution over the satellites is determined.

42 ENGINEERING↗

Predicting Orion Launch Abort Acoustics

Computational fluid dynamics (CFD) scale-resolving simulations were performed to help assess the Orion launch abort system’s vibro-acoustic environment in collaboration with the Orion Loads and Dynamics team at the Johnson Space Center (JSC). The primary objectives are to establish best practices and to validate CFD predictions for surface fluctuating pressure spectra with ground, wind tunnel, and flight test data. Excellent agreement is obtained between CFD predictions by the Cartesian adaptive mesh refinement (AMR) module of the Launch, Ascent, and Vehicle Aerodynamics (LAVA) solver and measurements from a ground test representative of the start of a pad abort scenario, and with measurements from a wind tunnel test case corresponding to a transonic, high total angle of attack ascent abort scenario. A simplified (static and at rest) simulation of a pad abort flight test shows good agreement with the flight data, whereas a more costly simulation where the vehicle is accelerating relative to the ground from rest to Mach 0.4 shows consistent over-prediction of the spectra. Simulation results for a supersonic ascent abort flight test are in reasonable agreement with the measurements, but show larger excursions in regions where non-linear interactions between the plume turbulence, shocks, and turbulent boundary layer are strongest – likely due to CFD modeling assumptions, the effect of which are discussed. Overall, the CFD results demonstrate that scale-resolving simulation methodologies like the one presented can help characterize full-scale launch abort vehicle near-field noise and can complement wind tunnel, ground and flight tests by providing trends and reducing uncertainty for scenarios that cannot or are not planned to be tested.

Orion↗

Rapid activation of non-oriented mechanophores via shock loading and spallation

Mechanophores (MPs), stimuli-responsive molecules that respond chromatically to mechanochemical reactions, are important for understanding the coupling between mechanics and chemistry as well as in engineering applications. However, the atomic-level understanding of their activation originates from gas phase studies or under simple linear elongation forces directly on molecules or polymer chains containing MPs. The effect of many-body distortions, pervasive in condensed-phase applications, is not understood. Therefore, we performed large-scale molecular dynamics (MD) simulations of a poly(methyl methacrylate)-spiropyran copolymer under dynamic mechanical loading and studied the activation of the MP under various conditions from dynamical compression to tension during unloading. Detailed analysis of the all-atom MD trajectories shows that the MP blocks experience significant many-body intramolecular distortion that can significantly decrease the activation barrier as compared with when deformation rates are slow relative to molecular relaxation time scales. Here we find that the reactivity of MPs under material compression states is governed by many-body effects of intramolecular torsions, whereas under tension, the reactions are governed by tensile stresses.

36 MATERIALS SCIENCE↗

Evaluation of 1/100-Scale Mooring Systems for Wave Energy Converters

This study evaluates the feasibility, accuracy, and limitations of using 1/100th scale physical mooring systems to represent full-scale mooring behavior for wave energy converters (WECs) during small-scale tank testing. The work focuses on an RM3-style point absorber deployed in conditions representative of the PacWave South test site and examines whether small-scale physical testing can reliably inform numerical modeling, design decisions, and future prototype development. Overall, this study concludes that small-scale (1/100th) physical mooring models can provide valuable qualitative insights, including relative comparisons between mooring types and trends in device behavior, but cannot reliably replicate full-scale mooring loads or dynamic response without significant scaling distortion. Physical tests at this scale are most appropriate for motion characterization and model validation within known limitations, not for deriving absolute mooring loads or final engineering design values. Key lessons learned emphasize the importance of improved instrumentation strategies, iterative wave tank tuning, more precisely manufactured scaled mooring components, and enhanced anchoring systems to reduce experimental uncertainty.

16 TIDAL AND WAVE POWER↗

The Hard Life of Floatovoltaics: Modeling Wind-Driven Oscillations of Floating Solar Panels

Modern, thin photovoltaic (PV) panels for solar power are susceptible to high stress loads in windy conditions. Manufacturers are eager to determine optimal installation practices to reduce these loads, including in the relatively new practice of installing PV on floating structures located on artificial and natural lakes. As part of our effort to develop simulation capabilities for stress on such floating PV systems, we here present our combined model-simulation approach, which simulates the dynamic wind loading and uses modeled elements to capture both the hydrodynamic and mooring-line forces. We discuss the forces important for our model and the challenges inherent in our simulation. Of particular interest is our model of the hysteresis response displayed by the attached mooring lines, which are engineered to damp motion and oscillation of the floating panel system. We validate our approach against the benchmark problem of vortex-induced vibration of a cylinder, which is driven by the same dynamic forces present in floating PV panels.

floating↗

An investigation of the loads on the vertical tail of a jet-bomber airplane resulting from flight through rough air

Vertical-tail loads were measured in turbulent air on a four-engine jet bomber. Results showed large load oscillations which were lightly damped. Comparison of experimental results with discrete-load calculations indicated that discrete-gust calculations underestimated the loads by 30 to 40 percent and gave no indication of the low damping. Power spectral analysis, on the other hand, indicated the general frequency characteristics and gave a somewhat better estimate of the peak-load distributions. The present results strongly suggest that discrete-gust calculation for gust loads on vertical tails may seriously underestimate the gust loads for airplanes having lightly damped lateral oscillations.

GUSTS, FREQUENCY↗

The effects of defects on copper melting under hydrostatic and shock loading

With molecular dynamics (MD) simulations, we investigate the effects of defects on Cu melting under hydrostatic and shock wave loading. We explore preexistent defects including vacancies, stacking faults and grain boundaries, as well as shock-induced defects. Depending on defect characteristics (energy and concentration), defects may have negligible or considerable effects on melting at MD scales However, it is expected that defects have more pronounced effects at heating rates lower than the MD rates.

36 MATERIALS SCIENCE↗

ELM 1016706669-AA B581 GDE01 Generator Summary pg 4-5 only

The table below shows the general load breakdown for 581GDE01. Although the total connected load exceeds the generator’s 150kW nameplate capacity, the normal configured load during standby power mode is less, which was measured at 81kW, or 54%, during preventive maintenance activities on 12/12/24. The generator’s available spare capacity must account for dynamically changing loads that can increase the total power demand at any time. If the two online VFD’s are operated at full speed the actual standby mode load is estimated to increase by 38kW, which would bring the total configured load during standby power mode to 119kW, or 79%, still within 581GDE01’s acceptable capacity. Per the LLNL Site 200 Generator Consolidation Final Study 2022, “Standby Emergency Generator nameplate ratings are based upon operation with varying load averaging 70% of the nameplate for 200 hours per year. Continuous loading between 70% and 100% will reduce a generator’s expected lifetime before a major overhaul. This is never a problem with Laboratory machines because of conservative application of generators and the reliability of the normal power system combines to keeps the load and hours down”. To achieve optimal performance and prolong generator life, the recommended generator loading is between 40% and 70%, optimally at 70%, which 581GDE01 appropriately falls within.

42 ENGINEERING↗