Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrically”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Optimal Gas-Electric Energy System Decarbonization Planning

As energy utilities implement climate change mitigation policies, system planners require strategies for achieving affordable emissions reductions. Coordinated planning of electric power and natural gas systems will allow synergistic investments to address cross-sector operational constraints, competing uses for net-zero emissions fuels, and shifts in energy demands across energy carriers. In this study, we develop a novel optimization program that finds the cost-minimizing mix of infrastructure expansion or reduction across gas and electric systems to satisfy sector-specific emissions constraints. Alongside energy supply resources, our framework allows for central-planning of end-use equipment stocks to allow switching between gas and electric appliances upon failure or premature replacement. The proposed model is used to simulate case study scenarios for a benchmark 24-pipe gas network coupled to a 24-node power system test network. We find that electrification of greater than 80% of core gas demands is a component of the least-cost solution for modeled energy systems. Despite this substitution, the gas system is maintained to service difficult-to-electrify customers and to deliver net-zero emissions gas to electricity generators in times of peak electricity demand. Restricting electrification of gas appliances increases reliance on power- to-gas technologies and increases annual costs by 15% in 2040. Neglecting constraints on pipeline blending of hydrogen can produce a misleading result that relies on hydrogen blend fractions of greater than 50%. In all cases, we find the average costs of delivered gas increase nearly 5-fold across the decarbonization transition, highlighting the importance of future work investigating cost-allocation strategies for ensuring an equitable energy transition.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Evaluating grid stress and reliability in future electricity grids across a range of demand, generation mix, and weather trends

The reliability of power grids in the future will depend on how system planners account for the integration of new technologies, extreme weather events, and uncertainties in demand growth from increased electrification and data centers. This study introduces an open-source, multisectoral, multiscale modeling framework that projects grid stress and reliability trends between 2020 and 2055 in the Western Interconnection of the United States. The framework integrates global to national energy-water-land dynamics with power plant siting and hourly grid operations modeling. We analyze future wholesale electricity price shocks and unserved energy events across eight scenarios spanning a range of population growth and economic change, generation mixes, and weather conditions. Our results show future grids with high percentage of non-renewable generation and strong economic growth are characterized by higher reliability and lower wholesale electricity prices than lower growth scenarios because of larger reliance on dispatchable generators and lower fossil fuel extraction costs. Scenarios with high percentage of renewable resources have lower median but more volatile wholesale electricity prices as well as more frequent and severe unserved energy events compared to scenarios relying more on dispatchable generators. These events occur because higher proportion of solar and wind energy causes net demand curves to deepen during midday (duck curves get progressively severe), exacerbating the challenge of meeting demand during summer evening peaks. This study suggests that robust and co-optimized transmission and energy storage planning could help maintain low wholesale electricity prices and high reliability levels in future electricity grids across uncertainties in generation mixes.

Electric grid reliability↗

3D-printed electrically conductive silicon carbide

The development of electrically conductive ceramics could achieve robust mechanical strength as well as practically high conductivity, offering applications in structural electrodes, conductors, catalyst supports, etc. However, its operating temperature is limited due to the intrinsic dense structures inevitably hindering the thermal management capability, thus resulting in a temperature-dependent electrical behavior in high-temperature environments. In this work, we report an additive manufacturing protocol through vat photopolymerization 3D printing to fabricate the architectured conductive silicon carbide (SiC) ceramics that simultaneously possess high electrical conductivity as well as low thermal conductivity, and demonstrate electric reliability under high-temperature environments above 600°C. The percolation of graphene into the ceramic scaffold establishes a uniform conductive network, exhibiting its electrical conductivity up to 1000 S m –1 . The bulk density of the 3D-printed ceramic is measured from 0.366 g cm –3 to 0.897 g cm –3 , with thermal conductivity ranging from 62 mW m –1 K –1 to 88 mW m –1 K –1 . Furthermore, the mechanical performance of conductive ceramic can be effectively reinforced by densifying the microstructures via spark plasma sintering treatment. The proposed additive manufacturing strategy widens the potential of ceramics as a structural and functional material, offering a promising pathway toward high-temperature electronics applications.

36 MATERIALS SCIENCE↗

Characterizing patterns and variability of building electric load profiles in time and frequency domains

The rapid development of advanced metering infrastructure provides a new data source—building electrical load profiles with high temporal resolution. Electric load profile characterization can generate useful information to enhance building energy modeling and provide metrics to represent patterns and variability of load profiles. Such characterizations can be used to identify changes to building electricity demand due to operations or faulty equipment and controls. In this study, we proposed a two-path approach to analyze high temporal resolution building electrical load profiles: (1) time-domain analysis and (2) frequency-domain analysis. Furthermore, the commonly adopted time-domain analysis can extract and quantify the distribution of key parameters characterizing load shape such as peak-base load ratio and morning rise time, while a frequency-domain analysis can identify major periodic fluctuations and quantify load variability. We implemented and evaluated both paths using whole-year 15-minute interval smart meter data of 188 commercial office building in Northern California. The results from these two paths are consistent with each other and complementary to represent full dynamics of load profiles. The time- and frequency-domain analyses can be used to enhance building energy modeling by: (1) providing more realistic assumptions about building operation schedules, and (2) validating the simulated electric load profiles using the developed variability metrics against the real building load data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-Driven Simulation-Based Planning for Electric Airport Shuttle Systems: A Real-World Case Study

Many airports are adopting battery electric buses in their shuttle fleets due to concerns over air quality and regulations. This study proposes a simulation-based optimization modeling framework to help airport shuttle operators effectively deploy electric buses. We evaluated a planned airport electric shuttle system with an event-driven simulator. Empirical data collected from existing systems were used to drive the simulations. We then proposed a simulation-based optimization model to determine the battery capacity, charging power, and number of chargers so that predefined objective(s) (e.g., minimizing total capital cost, minimizing emissions) are optimized. Compared to existing studies, the primary contribution of the proposed method is that it can model the real-world stochastic nature of operations in an electric bus system with much higher fidelity. To demonstrate the proposed modeling framework, we study a real-world shuttle system at the Dallas-Fort Worth International Airport, and present extensive numerical studies. When considering partial fleet electrification, the model can provide a set of Pareto optimal solutions. When considering full fleet electrification, the optimal solution requires a 50-kWh battery capacity and four 210-kW chargers, resulting in a total capital cost of $26,744,000. The results demonstrate that the proposed modeling framework can effectively optimize the planning of electric airport shuttle systems with partial or full fleet electrification.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

Effect of electrical field on TSA failure of cement-based materials

The impact of electrical field on the sulfate attack of cement-based materials at low temperatures was studied to rapidly detect Thaumasite Sulfate Attack (TSA) in the laboratory and in future engineering. Sulfate attack of cement paste with 30 wt% replacement of CaCO{sub 3} powder soaked in Na{sub 2}SO{sub 4} solution, MgSO{sub 4} solution, or CaSO{sub 4} solution was measured under the condition of 5 ± 2 °C when an electrical field was applied. Appearance changes and compressive strength of the samples were tested to evaluate the corrosion degree. Scanning Electron Microscopy (SEM), X-ray Diffraction (XRD), Fourier Transform Infrared Spectroscopy (FTIR) and Raman Spectroscopic measurements were applied to study the microstructure of the corrosion product. The test results indicate that sample damage was obvious, compression strength declined rapidly, and ettringite and/or thaumasite were found in the corrosion product after applying the electrical field for 90 days. A muddy product with TSA characteristics was formed, and thaumasite composition was found in the corrosion product after applying the electrical field for 120 days when MgSO{sub 4} solution was used as the corrosion medium. It is confirmed that an electrical field can accelerate TSA failure in cement-based materials.

36 MATERIALS SCIENCE↗

Experimental validation of a co-simulation architecture for modeling whole-building and detailed electrical distribution performance

This article presents an experimental validation of a co-simulation architecture for simultaneously modeling whole-building energy performance and detailed building electrical distribution system performance. The co-simulation architecture consists of a whole-building energy model (EnergyPlus®) embedded within a Modelica-based building electrical distribution system library called the Building Electrical Efficiency Analysis Model (BEEAM) using the Functional Mock-up Interface standard. We validate the model using experimental data collected at a full-scale test cell within Lawrence Berkeley National Laboratory’s FLEXLAB® facility. In conclusion, we show that the co-simulation model accurately predicts the electrical, mechanical, and thermal performance of the test cell for typical loads with both an AC and a DC electrical distribution topology.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Hydrogen underground storage for grid electricity storage: An optimization study on techno-economic analysis

Here, this study performs a techno-economic analysis of hydrogen underground storage systems for grid electricity storage, evaluating their economic viability at the plant scale using dynamic optimization. It explores the feasibility of various system configurations and revenue models in the context of volatile electricity prices and the necessity for multiple revenue streams. The hypothesis tested is that large-scale hydrogen storage, despite its low round-trip efficiency, can be economically viable with the right mix of revenue streams. This study uses scenario-based analysis to assess the impacts of different system configurations, including engaging in time-shifting arbitrage, ancillary service markets and blending hydrogen with natural gas. Results indicate potential annual net cash flows of up to $\$$1.5 million from ancillary services integration and $\$$5.2 million from natural gas blending, contingent on specific system sizes. The study concludes that hydrogen underground storage for grid electricity storage can be profitable, and emphasizes that proper system design and precise electricity price forecasting are crucial for optimizing system performance and economic returns. This research sets the stage for further investigations into the scalability of hydrogen storage systems and their broader implications for grid electricity storage and energy market dynamics.

25 ENERGY STORAGE↗

A view to the future of natural gas and electricity: An integrated modeling approach

This paper demonstrates the value of integrating two highly spatially resolved models: the Rice World Gas Trade Model (RWGTM) of the natural gas sector and the Regional Energy Deployment System (ReEDS) model of the U.S. electricity sector. The RWGTM passes electricity-sector natural gas prices to the ReEDS model, while the ReEDS model returns electricity-sector natural gas demand to the RWGTM. The two models successfully converge to a solution under reference scenario conditions. We present electricity-sector and natural gas sector evolution using the integrated models for this reference scenario. This paper demonstrates that the integrated models produced similar national-level results as when running in a stand-alone form, but that regional and state-level results can vary considerably. As we highlight, these regional differences have potentially significant implications for electric sector planners especially in the wake of substantive policy changes for the sector (e.g., the Clean Power Plan).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Influence of Climate Change Mitigation Technology on Global Demands of Water for Electricity Generation

Globally, electricity generation accounts for a large and potentially growing water demand, and as such is an important component to assessments of global and regional water scarcity. However, the current suite—as well as potential future suites—of thermoelectric generation technologies has a very wide range of water demand intensities, spanning two orders of magnitude. As such, the evolution of the generation mix is important for the future water demands of the sector. This study uses GCAM, an integrated assessment model, to analyze the global electric sector’s water demands in three futures of climate change mitigation policy and two technology strategies. We find that despite five- to seven-fold expansion of the electric sector as a whole from 2005 to 2095, global electric sector water withdrawals remain relatively stable, due to the retirement of existing power plants with water-intensive once-through flow cooling systems. In the scenarios examined here, climate policies lead to the large-scale deployment of advanced, low-emissions technologies such as carbon dioxide capture and storage (CCS), concentrating solar power, and engineered geothermal systems. In particular, we find that the large-scale deployment of CCS technologies does not increase long-term water consumption from hydrocarbon-fueled power generation as compared with a no-policy scenario without CCS. Moreover, in sensitivity scenarios where low-emissions electricity technologies are required to use dry cooling systems, we find that the consequent additional costs and efficiency reductions do not limit the utility of these technologies in achieving cost-effective whole-system emissions mitigation.

Climate policy↗

Electrical and seismic response of saline permafrost soil during freeze - Thaw transition

We conducted laboratory studies on the geophysical signals from Arctic saline permafrost soils to help understand the physical and mechanical processes during freeze-thaw cycles. Our results revealed low electrical resistivity (< 20 Ωm) and elastic moduli (7.7 GPa for Young's modulus and 2.9 GPa for shear modulus) at temperatures down to ~- 10 °C, indicating the presence of a significant amount of unfrozen saline water under the current field conditions. The spectral induced polarization signal showed a systematic shift during the freezing process, affected by concurrent changes of temperature, salinity, and ice formation. An anomalous induced polarization response was first observed during the transient period of supercooling and the onset of ice nucleation. Seismic measurements showed a characteristic maximal attenuation at the temperatures immediately below the freezing point, followed by a decrease with decreasing temperature. The calculated elastic moduli showed a non-hysteric response during the freeze – thaw cycle, which was different from the concurrently measured electrical resistivity response where a differential resistivity signal is observed depending on whether the soil is experiencing freezing or thawing. The differential electrical resistivity signal presents challenges for unfrozen water content estimation based on Archie's law. Using an improved formulation of Archie's law with a variable cementation exponent, the unfrozen water content estimation showed a large variation depending on the choice of the resistivity data during either a freezing or thawing cycle. Combining the electrical and seismic results, we suggest that, rather than a large hysteresis in the actual unfrozen water content, the shift of the resistivity response may reflect the changes of the distribution pattern of the unfrozen water (or ice) in the soil matrix during repeated freeze and thaw processes. Collectively, our results provide an improved petrophysical understanding of the physical and mechanical properties of saline permafrost during freeze – thaw transitions, and suggest that large uncertainty may exist when estimating the unfrozen water content using electrical resistivity data.

58 GEOSCIENCES↗

Vector tomography for reconstructing electric fields with non-zero divergence in bounded domains

In vector tomography (VT), the aim is to reconstruct an unknown multi-dimensional vector field using line integral data. In the case of a 2-dimensional VT, two types of line integral data are usually required. These data correspond to integration of the parallel and perpendicular projection of the vector field along the integration lines and are called the longitudinal and transverse measurements, respectively. In most cases, however, the transverse measurements cannot be physically acquired. Therefore, the VT methods are typically used to reconstruct divergence-free (or source-free) velocity and flow fields that can be reconstructed solely from the longitudinal measurements. In this paper, we show how vector fields with non-zero divergence in a bounded domain can also be reconstructed from the longitudinal measurements without the need of explicitly evaluating the transverse measurements. To the best of our knowledge, VT has not previously been used for this purpose. In particular, we study low-frequency, time-harmonic electric fields generated by dipole sources in convex bounded domains which arise, for example, in electroencephalography (EEG) source imaging. We explain in detail the theoretical background, the derivation of the electric field inverse problem and the numerical approximation of the line integrals. We show that fields with non-zero divergence can be reconstructed from the longitudinal measurements with the help of two sparsity constraints that are constructed from the transverse measurements and the vector Laplace operator. As a comparison to EEG source imaging, we note that VT does not require mathematical modeling of the sources. By numerical simulations, we show that the pattern of the electric field can be correctly estimated using VT and the location of the source activity can be determined accurately from the reconstructed magnitudes of the field. - Highlights: • Vector tomography is used to reconstruct electric fields generated by dipole sources. • Inverse solutions are based on longitudinal and transverse line integral measurements. • Transverse line integral measurements are used as a sparsity constraint. • Numerical procedure to approximate the line integrals is described in detail. • Patterns of the studied electric fields are correctly estimated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Determination of neutron irradiation temperatures of SiC using electrical resistivity method

The irradiation temperature of silicon carbide (SiC) was determined post-irradiation by examination of the recovery of the electrical resistivity due to thermal annealing in a rapid heating/cooling optical furnace. High-purity, high-resistivity grade SiC is routinely used as a passive temperature monitor in neutron irradiation studies at the High Flux Isotope Reactor (HFIR), and this paper presents an alternative automated technique for determination of the irradiation temperature the SiC experienced. Neutron collisions with the atoms results in displaced lattice atoms (interstitials) that act as electron donors yielding a significant decrease in electrical resistivity. The irradiation defects become thermodynamically unstable and start to recombine, when annealed above the irradiation temperature, resulting in a recovery of the electrical resistivity. The resistivity is measured at a fixed elevated temperature above ambient, which is below the target irradiation temperature. When the resistivity is plotted as a function of annealing temperatures, a clear increase is observed due to the recovery of irradiation defects. We have demonstrated that this electrical resistivity measurement of SiC is effective to determine irradiation temperature of SiC. In conclusion, energy levels of various defects in SiC were calculated from Arrhenius plots of electrical conductivity versus inverse temperature.

36 MATERIALS SCIENCE↗

Hydrogen effects on thermal diffusivity and electrical resistivity of zircaloy cladding

Thermal diffusivity measurements on Zirconium-based cladding materials have historically been a challenge due to the difficulty to measure on specimens with curved geometries, including nuclear grade Zircaloy cladding materials. Here, in this work, we first used laser flash analysis method and four-probe configuration method to measure the thermal diffusivity and electrical resistivity of Zircaloy tubes respectively, which show good agreement with Zircaloy plates in this work, as well as previously published data. The consistent results proved the applicability of the laser flash analysis setup and four-probe configuration method for investigating thermal diffusivity and electrical resistivity of Zircaloy tubes. We further investigated the hydrogen effect on thermal diffusivity and electrical resistivity of Zircaloy. Hydrogen plays significant roles in the thermal diffusivity of Zircaloy, which depends on the hydrogen concentration. For higher hydrogen contents (1130 and 1820 wppm in this work), where phase transformation (α-Zr + δ-hydride → α-Zr + β-Zr) occurs at 567 °C, thermal diffusivity decreases as a function of temperature at the α-Zr + δ-hydride phase regime, while increase at higher temperature at the α-Zr + β-Zr phase regime. For low hydrogen concentration, where hydride dissolved into α-Zr matrix phase at higher temperature, the thermal diffusivity is lower than non-hydrided Zircaloy-4 with similar temperature-dependent trends. Such observation demonstrates the hydrogen effects on reducing thermal diffusivity of α-Zr phase. Hydrogen increases the electrical resistivity of Zircaloy. Similar to thermal diffusivity results, the phase transformation causes a reversal of temperature-dependent trends in electrical resistivity results in Zircaloy-4 with higher hydrogen contents.

36 MATERIALS SCIENCE↗

Electron microscopy analyses and electrical properties of the layered Bi{sub 2}WO{sub 6} phase

The bismuth tungstate Bi{sub 2}WO{sub 6} was synthesized using a classical coprecipitation method followed by a calcination process at different temperatures. The samples were characterized by X-ray diffraction, simultaneous thermogravimetry and differential thermal analysis (TGA/DTA), scanning and transmission electron microscopy (SEM, TEM) analyses. The Rietveld analysis and electron diffraction clearly confirmed the Pca2{sub 1} non centrosymmetric space group previously proposed for this phase. The layers Bi{sub 2}O{sub 2}{sup 2+} and WO{sub 4}{sup 2−} have been directly evidenced from the HRTEM images. The electrical properties of Bi{sub 2}WO{sub 6} compacted pellets systems were determined from electrical impedance spectrometry (EIS) and direct current (DC) analyses, under air and argon, between 350 and 700 °C. The direct current analyses showed that the conduction observed from EIS analyses was mainly ionic in this temperature range, with a small electronic contribution. Electrical change above the transition temperature of 660 °C is observed under air and argon atmospheres. The strong conductivity increase observed under argon is interpreted in terms of formation of additional oxygen vacancies coupled with electron conduction. - Graphical abstract: High resolution transmission electron microscopy: inverse fast Fourier transform giving the layered structure of the Bi{sub 2}WO{sub 6} phase, with a representation of the cell dimensions (b and c vectors). The Bi{sub 2}O{sub 2}{sup 2+} and WO{sub 4}{sup 2−} sandwiches are visible in the IFFT image. - Highlights: • Using transmission electron microscopy, we visualize the layered structure of Bi{sub 2}WO{sub 6}. • Electrical analyses under argon gas show some increase in conductivity. • The phase transition at 660 °C is evidenced from electrical modification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mg dopant in Cu{sub 2}ZnSnSe{sub 4}: An n-type former and a promoter of electrical mobility up to 120 cm{sup 2} V{sup −1} s{sup −1}

Mg-doped Cu{sub 2}ZnSnSe{sub 4} (CZTSe) bulk materials with the (Cu{sub 2−x}Mg{sub x})ZnSnSe{sub 4} formula at x=0, 0.1, 0.2, 0.3, and 0.4 were prepared at 600 °C for 2 h with soluble sintering aids of Sb{sub 2}S{sub 3} and Te. Defect chemistry was studied by measuring structural and electrical properties of Mg-doped CZTSe as a function of dopant concentration. Except at x=0, all Mg-doped CZTSe pellets showed an n-type behavior. The Mg-doped CZTSe pellets showed an n-type behavior. n-Type Mg-CZTSe pellets at x=0.1 showed the highest electrical conductivity of 24.6 S cm{sup −1} and the net hole mobility of 120 cm{sup 2} V{sup −1} s{sup −1}, while they were 11.8 S cm{sup −1} and 36.5 cm{sup 2} V{sup −1} s{sup −1} for the undoped p-type CZTSe. Mg dopant is a strong promoter of electrical mobility. Mg dopant behaves as a donor defect in CZTSe at a 5% doping content, but is also used as an acceptor at a high content above 5%. Mg doping has further developed CZTSe into a promising semiconductor. - Graphical abstract: The effects of extrinsic doping of Mg{sup 2+} on the electrical properties of Cu{sub 2}ZnSnSe{sub 4} bulks. - Highlights: • (Cu{sub 2−x}Mg{sub x})ZnSnSe{sub 4} bulks were fabricated by liquid-phase sintering at 600 °C. • All Mg-x-CZTSe pellets except at x=0 exhibited n-type conductivity. • Electrical properties of CZTSe pellets changed with the Cu and Mg ratios. • Mg{sup 2+} goes to the Cu{sup 1+} site to form the Mg{sub Cu}{sup 1+} donor defect for the n-type CZTSe. • n-Type Mg-0.1-CZTSe bulk with 5% Mg showed the highest mobility of 120 cm{sup 2} V{sup −1} s{sup −1}.

36 MATERIALS SCIENCE↗

Mg dopant in Cu{sub 2}SnSe{sub 3}: An n-type former and a promoter of electrical mobility up to 387 cm{sup 2} V{sup −1} s{sup −1}

Mg-doped Cu{sub 2}SnSe{sub 3} bulk materials with the (Cu{sub 2−x}Mg{sub x})SnSe{sub 3} (Mg-x-CTSe) formula at x=0, 0.05, 0.1, 0.15, and 0.2 were prepared at 550 °C for 2 h with soluble sintering aids of Sb{sub 2}S{sub 3} and Te. Defect chemistry was studied by measuring structural and electrical properties of Mg-doped Cu{sub 2}SnSe{sub 3} as a function of dopant concentration. Mg-x-CTSe pellets show p-type at x=0, 0.05 and 0.1 and n-type at x=0.15 and 0.2. The low hole concentration of 3.2×10{sup 17} cm{sup −3} and high mobility of 387 cm{sup 2} V{sup −1} s{sup −1} were obtained for (Cu{sub 2−x}Mg{sub x})SnSe{sub 3} bulks at x=0.1 (5% Mg) as compared to 2.2×10{sup 18} cm{sup −3} and 91 cm{sup 2} V{sup −1} s{sup −1} for the undoped one. The explanation based upon the Mg-to-Cu antisite donor defect for the changes in electrical property was declared. A high Mg content for Mg-x-CTSe at x≥0.1 can lead to the formation of second phases. The study in bulk Mg-x-CTSe has been based upon defect states and is consistent and supported by the data of structural and electrical properties. - Graphical abstract: The effects of extrinsic doping of Mg{sup 2+} on the electrical properties of Cu{sub 2}SnSe{sub 3} bulks. - Highlights: • p-Type Mg-CTSe with n{sub p} of 3.2×10{sup 17} cm{sup −3} and μ{sub p} of 387 cm{sup 2} V{sup −1} s{sup −1} was obtained. • This p-type occurred for 5%Mg-doped CTSe with the (Cu{sub 1.9}Mg{sub 0.1})SnSe{sub 3} formula. • Mg dopant acts as a donor to lower n{sub p} and an accelerator to increase mobility. • High Mg content leads to the p-to-n transitions. • Defect was explored by measuring electrical property and lattice parameter.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evolution of mechanical properties of ultrafine grained 1050 alloy annealing with electric current

The tensile properties and microstructures of 1050 aluminum alloy prepared by equal channel angular pressing at cryogenic temperature (cryoECAP) after electric current annealing at 90–210 °C for 3 h were investigated by tensile test, electron back scattering diffraction (EBSD) and transmission electron microscopy (TEM). An unexpected annealing-induced strengthening phenomenon occurs at 90–210 °C, due to a significant decrease in the density of mobile dislocations after annealing, and thus a higher yield stress is required to nucleate alternative dislocation sources during tensile test. The electric current can enhance the motion of dislocations, lead to a lower dislocation density at 90–150 °C, and thus shift the peak annealing temperature from 150 °C to 120 °C. Moreover, the electric current can promote the migration of grain boundaries at 150–210 °C, result in a larger grain size at 150 °C and 210 °C, and thus causes a lower yield stress. The sample annealed with electric current has a lower uniform elongation at 90–120 °C, and the deviation in the uniform elongation between samples annealed without and with electric current becomes smaller at 150–210 °C. - Highlights: • An unexpected annealing-induced strengthening phenomenon occurs at 90–210 °C. • The d. c. current can enhance the motion of dislocations at 90–150 °C, and thus shift the peak annealing temperature from 150 °C to 120 °C. • The d. c. current can promote the grain growth at 150–210 °C, and thus cause a lower yield stress. • The DC annealed sample has a lower uniform elongation at 90–120 °C.

36 MATERIALS SCIENCE↗