Search NASA⌕ Search

SEARCH · Search NASA

Results for “experimental setup”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

An experimental comparison of triggered and random pulse train uncertainties

In this paper we present an experimental comparison of signal-triggered and randomly triggered based analysis algorithms of neutron multiplicity data. Traditional shift register type signal-triggered multiplicity analysis of singles, doubles and triples rates is compared with analysis using randomly triggered gates. Two methods of random gate generation are explored - non-overlapping gates (Feyrunan approach) and periodic overlapping gates (fast accidentals). Using californium sources with low, medium and high rate in combination with AmLi sources (as a surrogate for plutonium) we investigate relative standard deviation (RSD) of data in order to determine if there are parameter spaces in which one of the measurement methods should be preferred. Neutron correlation analysis is a commonly used NDA technique to assay plutonium mass. The data can be collected in two distinct ways: using signal-triggered or randomly triggered counting gates. Analysis algorithms were developed for both approaches to determine singles (S), doubles (D) and triples (7) rates from the measured sample. Currently the most commonly implemented technique to collect neutron coincidence data utilizes shift register based electronics. Shift register uses signal-triggered counting gates to generate foreground multiplicity distribution of correlated+accidental events and a random gate (opened after a predefined long delay following the signal trigger) to generate background multiplicity distribution of accidental events. Modern shift registers include fast accidental option to sample data with a fixed clock frequency. This way a set of overlapping gates is used to generate background multiplicity distributions in order to improve the measurement precision. In parallel to shift register approach the Feynman variance technique is frequently used, which utilizes set of consecutive non-overlapping gates. In general, different user communities (e.g. safeguards, nuclear material accountancy, emergency response) have used only one of the two analysis methods for the nuclear material assay. The aim of this study is to provide a systematic comparison of the precision of the measured S, D, T rates and {sup 240}Pu effective mass obtained using the above mentioned pulse train sampling techniques. In order to perform this task, a LANL developed list mode based data acquisition system is used, where the entire pulse train is recorded and subsequently analyzed. The list mode acquisition brings an essential advantage for this type of comparison, since the very same pulse train can be analyzed using signal-triggered as well as randomly triggered counting gates. The aim of this study is not only to compare the precision of signal-triggered versus random triggered sampling techniques, but also to investigate the influence of fast accidental sampling on the precision of signal-triggered results. In addition the different random sampling techniques used in safeguards are investigated. For this purpose we implement two types of random sampling - non-overlapping gates (Feynrnan approach) and periodic overlapping gates (fast accidentals). In the following sections the equations utilized in the pulse train analysis are described, experimental setup and measurement techniques are discussed and finally the results are summarized and discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Proof-of-Principle Experiment for FEL-based Coherent Electron Cooling

Coherent electron cooling (CEC) has a potential to significantly boost luminosity of high-energy, high-intensity hadron-hadron and electron-hadron colliders*. In a CEC system, a hadron beam interacts with a cooling electron beam. A perturbation of the electron density caused by ions is amplified and fed back to the ions to reduce the energy spread and the emittance of the ion beam. To demonstrate the feasibility of CEC we propose a proof-of-principle experiment at RHIC using one of JLab’s SRF cryo-modules. In this paper, we describe the experimental setup for CeC installed into one of RHIC's interaction regions. We present results of analytical estimates and results of initial simulations of cooling a gold-ion beam at 40 GeV/u energy via CeC.

43 PARTICLE ACCELERATORS↗

Emittance Measurements of the SSRL Gun Test Facility

A photocathode RF gun test stand is under construction in the injector vault of the Stanford Synchrotron Radiation Laboratory at SLAC. The goal of this facility is to produce an electron beam with a normalized emittance of 1-3[mm-mr], a longitudinal bunch duration of the order of 10[ps] FWHM and approximately 1[nC] of charge per bunch. The beam will be generated from a laser driven copper photocathode RF gun developed in collaboration with BNL, LBL and UCLA. The 3-5[MeV] beam from the gun will be accelerated using a SLAC three meter S-band accelerator section. The emittance of the electron beam will be measured through the use of quadrupole scans with phosphor screens and also a wire scanner. The details of the experimental setup will be discussed, and first measurements will be presented and compared with results from PARMELA simulations.

43 PARTICLE ACCELERATORS↗

Noise modeling from high-permeability shields using Kirchhoff equations

Progress in the development of high-sensitivity magnetic-field measurements has stimulated interest in understanding magnetic noise of conductive materials, especially of magnetic shields (DC or rf) based on high-permeability materials and/or high-conductivity materials. For example, SQUIDs and atomic magnetometers have been used in many experiments with mu-metal shields, and additionally SQUID systems frequently have rf shielding based on thin conductive materials. Typical existing approaches to modeling noise only work with simple shield and sensor geometries while common experimental setups today consist of multiple sensor systems arbitrary shapes and complex shield geometries. With complex sensor arrays used in, for example, MEG and Ultra Low Field MRI studies the knowledge of the noise correlation between sensors is as important as the knowledge of the noise itself. This is crucial for incorporating efficient noise cancelation schemes for the system. We developed an approach that allows us to calculate the Johnson noise for any geometrically shaped shield and multiple sensor systems. The approach uses a fraction of the processing power of other approaches and with a multiple sensor system our approach not only calculates the noise for each sensor but it also calculates the noise correlation matrix between sensors. Here we will show the algorithm and examples where it can be implemented.

42 ENGINEERING↗

Fire tests and analyses of a rail cask-sized calorimeter.

Three large open pool fire experiments involving a calorimeter the size of a spent fuel rail cask were conducted at Sandia National Laboratories Lurance Canyon Burn Site. These experiments were performed to study the heat transfer between a very large fire and a large cask-like object. In all of the tests, the calorimeter was located at the center of a 7.93-meter diameter fuel pan, elevated 1 meter above the fuel pool. The relative pool size and positioning of the calorimeter conformed to the required positioning of a package undergoing certification fire testing. Approximately 2000 gallons of JP-8 aviation fuel were used in each test. The first two tests had relatively light winds and lasted 40 minutes, while the third had stronger winds and consumed the fuel in 25 minutes. Wind speed and direction, calorimeter temperature, fire envelop temperature, vertical gas plume speed, and radiant heat flux near the calorimeter were measured at several locations in all tests. Fuel regression rate data was also acquired. The experimental setup and certain fire characteristics that were observed during the test are described in this paper. Results from three-dimensional fire simulations performed with the Cask Analysis Fire Environment (CAFE) fire code are also presented. Comparisons of the thermal response of the calorimeter as measured in each test to the results obtained from the CAFE simulations are presented and discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermodynamic and kinetic characterization of H-D exchange in Pd and Pd alloys.

A Sieverts apparatus coupled with an RGA is an effective method to detect composition variations during isotopic exchange. This experimental setup provides a powerful tool for the thermodynamic and kinetic characterization of H-D isotope exchange on metals and alloys. H-D exchange behavior during absorption and desorption in the plateau region in Pd have been investigated and reported here. It was found that in the plateau region of H-D-Pd system the equilibrium pressures are between those of H2-Pd and D2-Pd for both absorption and desorption and the equilibrium pressures are higher when the fractions of D in the Pd are higher. Adding a dose of gas H2 (or D2) to Pd-D (or Pd-H) system results in releasing of gas D2 and HD (or H2 and HD) in {beta}-phase of Pd-D (or {beta}-phase of Pd-H), but this does not happen in the plateau region. The equilibrium constants have been determined during exchange and it was found that they agree well with the calculated values reported in literature. The separation factor {alpha} values during exchange have been measured and compared with the literature values. The exchange rates have been determined from the exchange profiles and a first order kinetic model for the exchange of H-D-Pd systems has been employed for the analysis. The exchange activation energies for both directions, H2+PdD and D2+PdH, have been determined.

36 MATERIALS SCIENCE↗

Model-Independent Characterization of Charge Diffusion in Thick Fully Depleted CCDs

We present a new method to measure charge diffusion in charge-coupled devices (CCDs). The method is based on a statistical characterization of the shapes of charge clouds produced by low-energy X-rays using known properties of the two-dimensional Gaussian point-spread function (PSF). The algorithm produces reliable upper and lower bounds on the size of the PSF for photons converting near the entrance window of a device. It is optimally suited to the case of thick back-illuminated CCDs where the X-ray absorption length is smaller than the silicon thickness and the diffusion scale is of the same order as the pixel size. The only assumptions are that the charge cloud width is a monotonically increasing function of distance from the conversion point to the buried channel, and that the conversion probability is peaked at the surface. Otherwise, no physical models of carrier transport or knowledge of the electric field profile in the CCD are needed. In suboptimal conditions, the upper bound increases and the lower bound is unaffected, so confidence in the correctness of results is retained. The new method has been benchmarked against Monte Carlo simulations and tested on X-ray images measured on thick high-resistivity prototype CCDs for the Large Synoptic Survey Telescope. In Monte Carlo simulations of noiseless images having the optimal diffusion scale, the upper bound approximated the true PSF within 5%, increasing to 10% in simulations with added noise. Even with severely undersampled or truncated PSFs, the method brackets the true value to within 25%. Our method is accurate and computationally efficient and offers a fast and simple experimental setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Capture Measurements on Minor Actinides at the n_TOF Facility at CERN: Past, Present and Future

The successful development of advanced nuclear systems for sustainable energy production and nuclear waste management depends on high quality nuclear data libraries. Recent sensitivity studies and reports have identified the need for substantially improving the accuracy of neutron cross-section data for minor actinides. The n-TOF collaboration has initiated an ambitious experimental program for the measurement of neutron capture cross sections of minor actinides. Two experimental setups have been constructed for this purpose: a Total Absorption Calorimeter (TAC) for measuring neutron capture cross-sections of low-mass and/or radioactive samples and a set of two low neutron sensitivity C{sub 6}D{sub 6} detectors for the less radioactive materials.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of Scanning Near-Field Ultrasound Holography as an Add-On Module for AFM systems

The project aimed to develop a standalone module for Atomic Force Microscope systems that the biological and environmental research community could use to image and quantify to a greater extent the interactions between nanoparticles and cells. If successful, it would enable the thousands of biological and environmental researchers with access to atomic force microscopes to perform scanning near field ultrasound holography to image nanoparticle interactions with cells. Over the course of this effort, grantees were able to develop a standalone module capable of performing scanning near field ultrasound holography on a variety of commercial systems. The add-on module was tested on systems from 3 of the major Atomic Force Microscope manufacturers (Veeco, JEOL and Park Systems). Furthermore, the investigators believe that the hardware developed will be capable of performing the technique on any AFM with standard signal access modules. The discrete components previously used to perform the SNFUH technique could cost upward of $\$$40,000. Beyond the cost issue, the components are bulky and cumbersome to work with because of the wiring needed between each of the components when implementing the technique. NanoSonix was able to dramatically reduce both the cost and complexity of implementing SNFUH, developing two functional versions of an add-on module (A&B) using National Instruments hardware as put forth in the proposal. More significantly, NanoSonix exceeded the aims of the proposal by developing completely custom electronics that should enable an almost order of magnitude cost reduction while improving the capability versus the discrete componentry. Because potential biological systems are so complex, biological applications of the technique are very diverse and require very distinct domain knowledge. This inhibits the utilization widespread adoption and penetration of new metrology techniques. Northwestern University and NanoSonix has made it both possible and practical for widespread adoption of the technique through the development of a standalone system with order of magnitude cost reduction and significant reduction in complexity. NanoSonix believes that it can produce the add-on modules and make them available to the academic research community at a price point below $\$$10,000, thereby enabling the biological research community to hardness the over 30,000 AFMs in existence around the world today, approximately 18,000 of which reside in the United States at a very modest incremental cost. Finally, we were able to implement a multi-frequency function generator and simultaneous multi-frequency lock-in amplifier with an internal reference frequency (which significantly simplifies the experimental setup) that it believes could lay the foundation for future non-destructive nanoscale 3-D tomography of buried and embedded sub-structures in cells and tissues. To date, we has been unable to find multiple frequency combinations which yield sufficiently strong mixing at the tip-sample interaction, but believes it is conceptually possible and doing so would enable the use of frequency dependent phase shift to better characterize the subsurface structures. Taken together, we believes that this work has materially advanced the prospects of enabling researchers to develop time-resolved cellular uptake of the nanoparticles used for drug delivery, cancer therapies, gene delivery and gene silencing and to assess cellular uptake of nanoparticles for environmental monitoring/remediation/impact.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Performance comparison of fiber optic tips in interferrometric displacement measurement

Fiber optic displacement sensors have many potential advantages over traditional displacement measurement techniques, including small size, immunity to electromagnetic interference, electrical isolation, and high resolution. In this report, we focus on an interferometric fiber optic sensor, where the gap between the fiber tip and the device under test forms a Fabry-Perot resonant cavity. An optical interrogator measures the reflected intensity at wavelengths ranging from 1510 to 1590 nm. The spacing between resonant frequencies allows us to determine the distance from the tip to the device under test. We consider ferrule connector angled physical contact (FC/APC), ferrule connector ultra physical contact (FC/UPC) and unpolished cleaved tips and compare their influence on sensor performance. A plane wave propagation model is proposed for predicting tip effects. Comparisons are made on the basis of sensor measurement range, resolution, and sensitivity to changes in test conditions. In this paper, we discuss the experimental setup, detail our analysis, and present test results with recommendations for the applications of each tip.

42 ENGINEERING↗

A Flow-through Reaction Cell that Couples Time-resolved X-ray Diffraction with Stable Isotope Analysis

A non-metallic flow-through reaction cell is described, designed for in situ time-resolved X-ray diffraction coupled with stable isotope analysis. The experimental setup allows the correlation of Cu isotope fractionation with changes in crystal structure during copper sulfide dissolution. This flow-through cell can be applied to many classes of fluid-mineral reactions that involve dissolution or ion exchange.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Intelligent Detector Design

As the complexity and resolution of imaging detectors increases, the need for detailed simulation of the experimental setup also becomes more important. Designing the detectors requires efficient tools to simulate the detector response and reconstruct the events. We have developed efficient and flexible tools for detailed physics and detector response simulation as well as event reconstruction and analysis. The primary goal has been to develop a software toolkit and computing infrastructure to allow physicists from universities and labs to quickly and easily conduct physics analyses and contribute to detector research and development. The application harnesses the full power of the Geant4 toolkit without requiring the end user to have any experience with either Geant4 or C++, thereby allowing the user to concentrate on the physics of the detector system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mesh size and code option effects of strength calculations

Modern Lagrangian hydrodynamics codes include numerical methods which allow calculations to proceed past the point obtainable by a purely Lagrangian scheme. These options can be employed as the user deems necessary to 'complete' a calculation. While one could argue that any calculation is better than none, to truly understand the calculated results and their relationship to physical reality, the user needs to understand how their runtime choices affect the calculated results. One step toward this goal is to understand the effect of each runtime choice on particular pieces of the code physics. This paper will present simulation results for some experiments typically used for strength model validation. Topics to be covered include effect of mesh size, use of various ALE schemes for mesh detangling, and use of anti-hour-glassing schemes. Experiments to be modeled include the lower strain rate ({approx} 10{sup 4} s{sup -1}) gas gun driven Taylor impact experiments and the higher strain rate ({approx} 10{sup 5}-10{sup 6} s{sup -1}) HE products driven perturbed plate experiments. The necessary mesh resolution and the effect of the code runtime options are highly dependent on the amount of localization of strain and stress in each experiment. In turn, this localization is dependent on the geometry of the experimental setup and the drive conditions.

97 MATHEMATICS AND COMPUTING↗

Bunch Length Measurements With Laser/SR Cross-Correlation

By operating SPEAR3 in low-{alpha} mode the storage ring can generate synchrotron radiation pulses of order 1ps. Applications include pump-probe x-ray science and the production of THz radiation in the CSR regime. Measurements of the bunch length are difficult, however, because the light intensity is low and streak cameras typically provide resolution of only a few ps. Tests are now underway to resolve the short bunch length using cross-correlation between a 60-fs Ti:Sapphire laser and the visible SR beam in a BBO crystal. In this paper we report on the experimental setup, preliminary measurements and prospects for further improvement.

43 PARTICLE ACCELERATORS↗

Status of Proof-of-principle Experiment for Coherent Electron Cooling

Coherent electron cooling (CEC) has a potential to significantly boost luminosity of high-energy, high-intensity hadron colliders. To verify the concept we conduct proof-of-the-principle experiment at RHIC. In this paper, we describe the current experimental setup to be installed into 2 o'clock RHIC interaction regions. We present current design, status of equipment acquisition and estimates for the expected beam parameters.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Status of proof-of-principle experiment for coherent electron cooling

Coherent electron cooling (CEC) has a potential to significantly boost luminosity of high-energy, high-intensity hadron colliders. To verify the concept we conduct proof-of-the-principle experiment at RHIC. In this paper, we describe the current experimental setup to be installed into 2 o'clock RHIC interaction regions. We present current design, status of equipment acquisition and estimates for the expected beam parameters. We use a dogleg to merge the electron and ion beams. The ions 'imprint' their distribution into the electron beam via a space charge density modulation. The modulation is amplified in an FEL comprised of a 7-m long helical wiggler. The ions are co-propagating with electron beam through the FEL. The ion's average velocity is matched to the group velocity of the wave-packet of e-beam density modulation in the FEL. A three-pole wiggler at the exit of the FEL tune the phase of the wave-packet so the ion with the central energy experience the maximum of the e-beam density modulation, where electric field is zero. The time-of-flight dependence on ion's provides for the electrical field caused by the density modulation to reduce energy spread of the ion beam. The used electron beam is bent off the ion path and damped.

43 PARTICLE ACCELERATORS↗

Performance comparison of fiber tips in interferometric displacement mesurements

Fiber optic displacement sensors have many potential advantages over traditional displacement measurement techniques, including small size, immunity to electromagnetic interference, electrical isolation, and high resolution. In this report, we focus on an interferometric fiber optic sensor, where the gap between the fiber tip and the device under test forms a Fabry-Perot resonant cavity. An optical interrogator measures the reflected intensity at wavelengths ranging from 1510 to 1590 nm. The spacing between resonant frequencies allows us to determine the distance from the tip to the device under test. We consider ferrule connector angled physical contact (FC/APC), ferrule connector ultra physical contact (FC/UPC) and unpolished cleaved tips and compare their influence on sensor performance. A plane wave propagation model is proposed for predicting tip effects. Comparisons are made on the basis of sensor measurement range, resolution, and sensitivity to changes in test conditions. In this paper, we discuss the experimental setup, detail our analysis, and present test results with recommendations for the applications of each tip.

42 ENGINEERING↗

The proton form factor ratio results from Jefferson Lab

The ratio of the proton form factors, GE p/GMp, has been measured extensively, from Q2 of 0.5 GeV2 to 8.5 GeV2, at the Jefferson Laboratory, using the polarization transfer method. This ratio is extracted directly from the measured ratio of the transverse and longitudinal polarization components of the recoiling proton in elastic electron-proton scattering. The polarization transfer results are of unprecedented high precision and accuracy, due in large part to the small systematic uncertainties associated with the experimental technique. There is an approved experiment at JLab, GEP(5), to continue the ratio measurements to 12 GeV2. A dedicated experimental setup, the Super Bigbite Spectrometer (SBS), will be built for this purpose. It will be equipped with a focal plane polarimeter to measure the polarization of the recoil protons. The scattered electrons will be detected in an electromagnetic calorimeter. In this presentation, I will review the status of the proton elastic electromagnetic form factors and discuss a number of theoretical approaches to describe nucleon form factors.

43 PARTICLE ACCELERATORS↗