Search NASA⌕ Search

SEARCH · Search NASA

Results for “grating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Fiber Optic Thermal Health Monitoring of Composites

A recently developed technique is presented for thermographic detection of flaws in composite materials by performing temperature measurements with fiber optic Bragg gratings. Individual optical fibers with multiple Bragg gratings employed as surface temperature sensors were bonded to the surfaces of composites with subsurface defects. The investigated structures included a 10-ply composite specimen with subsurface delaminations of various sizes and depths. Both during and following the application of a thermal heat flux to the surface, the individual Bragg grating sensors measured the temporal and spatial temperature variations. The data obtained from grating sensors were analyzed with thermal modeling techniques of conventional thermography to reveal particular characteristics of the interested areas. Results were compared with the calculations using numerical simulation techniques. Methods and limitations for performing in-situ structural health monitoring are discussed.

Wu, Meng-Chou↗

Fiber Optic Thermal Detection of Composite Delaminations

A recently developed technique is presented for thermographic detection of delaminations in composites by performing temperature measurements with fiber optic Bragg gratings. A single optical fiber with multiple Bragg gratings employed as surface temperature sensors was bonded to the surface of a composite with subsurface defects. The investigated structure was a 10-ply composite specimen with prefabricated delaminations of various sizes and depths. Both during and following the application of a thermal heat flux to the surface, the individual Bragg grating sensors measured the temporal and spatial temperature variations. The data obtained from grating sensors were analyzed with thermal modeling techniques of conventional thermography to reveal particular characteristics of the interested areas. Results were compared and found to be consistent with the calculations using numerical simulation techniques. Also discussed are methods including various heating sources and patterns, and their limitations for performing in-situ structural health monitoring.

Wu, Meng-Chou↗

Adaptive Wavelength Scanning Lidar (AWSL) for 3D Mapping from Space

We present the design and performance of an adaptive wavelength scanning lidar (AWSL) for highly efficient mapping from low Earth orbit (LEO). Mapping is accomplished by steering a laser beam across 1,200 resolvable spots using wavelength tuning and grating dispersion. Any subset of these 1,200 spots can be selected by wavelength switching. The design is validated with an 1550-nm prototype using a fast wavelength-tuned (500-kHz) pulsed (2-ns) fiber laser with the beam dispersed by gratings for beam steering. Reflected pulses are detected with an eight-pixel detector array with single-photon sensitivity. Eight lidar returns are time-multiplexed to one output that is digitized with a single 1-GSPS-digitizer, to save power. A grating spectrometer rejects solar background noise spatially and spectrally, and images laser footprints on to the detector array. The gratings retain the fiber laser beam quality. We are developing a 1030-nm AWSL intended for a LEO SmallSat platform.

Guangning Yang↗

Hyper dispersion pulse compressor for chirped pulse amplification systems

A grating pulse compressor configuration is introduced for increasing the optical dispersion for a given footprint and to make practical the application for chirped pulse amplification (CPA) to quasi-narrow bandwidth materials, such as Nd:YAG. The grating configurations often use cascaded pairs of gratings to increase angular dispersion an order of magnitude or more. Increased angular dispersion allows for decreased grating separation and a smaller compressor footprint.

Barty, Christopher P. J.↗

Optically transduced MEMS gyro device

A bulk micromachined vibratory gyro in which a proof mass has a bulk substrate thickness for a large mass and high inertial sensitivity. In embodiments, optical displacement transduction is with multi-layer sub-wavelength gratings for high sensitivity and low cross-talk with non-optical drive elements. In embodiments, the vibratory gyro includes a plurality of multi-layer sub-wavelength gratings and a plurality of drive electrodes to measure motion of the proof mass induced by drive forces and/or moments and induced by the Coriolis Effect when the gyro experiences a rotation. In embodiments, phase is varied across the plurality gratings and a multi-layer grating having the best performance is selected from the plurality.

47 OTHER INSTRUMENTATION↗

Dispersion compensation in chirped pulse amplification systems

A chirped pulse amplification system includes a laser source providing an input laser pulse along an optical path. The input laser pulse is characterized by a first temporal duration. The system also includes a multi-pass pulse stretcher disposed along the optical path. The multi-pass pulse stretcher includes a first set of mirrors operable to receive input light in a first plane and output light in a second plane parallel to the first plane and a first diffraction grating. The pulse stretcher also includes a second set of mirrors operable to receive light diffracted from the first diffraction grating and a second diffraction grating. The pulse stretcher further includes a reflective element operable to reflect light diffracted from the second diffraction grating. The system further includes an amplifier, a pulse compressor, and a passive dispersion compensator disposed along the optical path.

42 ENGINEERING↗

Talbot-Lau X-ray Phase-Contrast Research at Johns Hopkins

The Talbot-Lau (T-L) grating interferometer enables X-ray differential phase-contrast (DPC) imaging with low coherence conventional X-ray tubes, being thus attractive for medical and other applications. We studied several variations of the conventional T-L interferometer design. First, to extend the T-L method to high X-ray energy we developed a symmetric interferometer having gratings inclined at a glancing angle (GAI). This simple setup enables achieving high fringe contrast up to 80 kVp or more. The high GAI contrast in turn enabled demonstrating for the first time DPC-CT of soft tissues with clinically compatible X-ray dose and energy. Industrial and security applications of the GAI appear also possible. Further on, we studied high magnification T-L interferometry for electron density diagnostic in high energy density plasmas. High magnification refraction radiography with laser driven backlighters can help understand inertial confinement fusion experiments for instance. For plasma diagnostic using a single radiographic image we develop Moiré fringe deflectometry. We also extended the T-L method below 10 keV using membrane and free standing gratings. Lastly, we explored using grazing incidence micro-periodic mirrors instead of gratings in the T-L interferometers. These enable in principle achieving very small interferometer periods over a broad energy range, at the price of a narrow field of view in one dimension. The possibility of using these designs for DPC imaging of materials under extreme conditions will also be examined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Metallic layer-by-layer photonic crystals for linearly-polarized thermal emission and thermophotovoltaic device including same

Metallic thermal emitters consisting of two layers of differently structured nickel gratings on a homogeneous nickel layer are fabricated by soft lithography and studied for polarized thermal radiation. A thermal emitter in combination with a sub-wavelength grating shows a high extinction ratio, with a maximum value close to 5, in a wide mid-infrared range from 3.2 to 7.8 .mu.m, as well as high emissivity up to 0.65 at a wavelength of 3.7 .mu.m. All measurements show good agreement with theoretical predictions. Numerical simulations reveal that a high electric field exists within the localized air space surrounded by the gratings and the intensified electric-field is only observed for the polarizations perpendicular to the top sub-wavelength grating. This result suggests how the emissivity of a metal can be selectively enhanced at a certain range of wavelengths for a given polarization.

14 SOLAR ENERGY↗

Modular Soft X-Ray Emission Spectrograph

We have been developing the Hettrick-Underwood type soft x-ray spectrograph for over a decade. This optical design uses one spherical mirror for focusing x-rays onto the CCD detector and a set of variable line-spacing gratings for energy analysis. Unlike the previous effort carried out at the ALS, what we have achieved in the current design is to incorporate the concept of modularity. The model of spectrograph is shown below. It contains three major components: the optics chamber and downstream section (detector plus driving mechanism using a swing arm pivoted at the grating location, see figure) for inside and outside order (translation stage without swing arm, not shown here). Inside order design is often used when source size is larger than the detector pixel resolution, while the outside order is used when source size is smaller than the detector pixel resolution. Irrespective to which order is selected, there is no change in the mechanism of optics chamber. The location of optics chamber relative to the source and detector can also be changed to optimize the energy resolution at target photon energy. The incident angles on mirror and gratings can be varied, in conjunction with the grating line densities, to balance the resolution and throughput. The internal components of optics chamber are also modular and changing the dimension of optics can be done by using different holders. The modularity not only greatly reduces the design and assembling effort, but also offers the cost benefit. Although the cost of this type of spectrograph is expected to be higher than XES350, it is still significant lower than the one-of-the-kind design used at every synchrotron facilities. The unique flexibility and modularity not only allows the users to tailor the design of spectrograph for the characteristic of their sources, but also to have cost down in standardizing the fabrication parts.

Hussain, Zahid↗

Polarization diversity optical interface assembly

Examples herein relate to polarization diversity optical interface assemblies including a single mode optical fiber and first and second grating couplers disposed on a substrate. The first and second grating couplers are coupled to first and second waveguides, respectively. The assemblies further includes an optical connector to couple light between the single mode optical fiber and each of the first and second grating couplers. The optical connector includes a ferrule and a walk-off crystal. The ferrule is coupled to a portion of the single mode optical fiber. The walk-off crystal is configured to spatially separate the light into first and second orthogonal polarization modes prior to passing through the respective first and second grating couplers and/or combine the first and second polarization modes of the light prior to passing through the single mode optical fiber.

42 ENGINEERING↗

Tunneling full-wave infrared rectenna

A rectenna is used for full-wave rectification of infrared radiation to produce electricity. In the rectenna, a metallic grating overlies a semiconductor body. A tunnel barrier is interposed between each grating element and the semiconductor body. Each of the grating elements overlies a bridge pair consisting of a region of n+-doped semiconductor and a region of p+-doped semiconductor, both of which are embedded in more lightly doped host semiconductor material. Each of the two regions that compose the bridge pair forms a rectifying tunnel junction through a tunnel barrier to at least one overlying grating element. Each of the two regions also forms a semiconductor junction with the host semiconductor material.

Davids, Paul↗

Single beam write and/or replay of spatial heterodyne holograms

A method of writing a spatially heterodyne hologram having spatially heterodyne fringes includes: passing a single write beam through a spatial light modulator that digitally modulates said single write beam; and focusing the single write beam at a focal plane of a lens to impose a holographic diffraction grating pattern on the photorefractive crystal, the holographic diffraction grating pattern including the spatially heterodyne hologram having spatially heterodyne fringes, wherein only said single write beam is incident on said photorefractive crystal without a reference beam. A method of replaying a spatially heterodyne hologram having spatially heterodyne fringes at a replay angle includes: illuminating a photorefractive crystal having a holographic diffraction grating with a beam from a laser at an illumination angle, the holographic diffraction grating pattern including the spatially heterodyne hologram having spatially heterodyne fringes, wherein a difference between said illumination angle and said replay angle defines a diffraction angle .alpha. that is a function of a plane wave mathematically added to original object wave phase and amplitude data of said spatially heterodyne hologram having spatially heterodyne fringes.

Thomas, Clarence E.↗

Bismuth-doped fibre laser continuously tunable within the range from 1.36 to 1.51 μm

A single-mode bismuth-doped fibre laser continuously tunable within the wavelength range from 1366 to 1507 nm with the help of an external diffraction grating has been developed. Such a wide wavelength tuning range is achieved by inserting a long-period fibre grating in the laser cavity. The grating smoothes the gain spectrum and thus ensures stable lasing at the edges of the above-mentioned spectral range. The output laser power varies from 25 mW at the tuning range edges to 50 mW in the centre upon pumping at 1.34 μm with a power of 300 mW. (paper)

42 ENGINEERING↗

Scaling in the Optical Characteristics of Aperiodic Structures with Self-Similarity Symmetry

The properties of diffraction gratings and multilayered systems constructed using 1D models of quasicrystals are considered based on numerical simulation. It is shown that there is a direct relationship between the self-similarity symmetry of quasicrystals and scaling in the characteristics of the above-mentioned optical devices. The degree of structural correspondence between the graphical representations of the geometric properties of crystals, light diffraction patterns of gratings, and the transmission spectra of multilayered systems is estimated. It is shown that certain types of self-similarity symmetry make the characteristics of aperiodic diffraction gratings highly stable to a change in the size ratio of forming elements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SiO 2 Nanoparticle Sequestration via Reactive Functionalization in Holographic Polymer-Dispersed Liquid Crystals

Holographic photopolymerization of reactively functionalized silica nanoparticles in polymer/liquid-crystal systems leads to sequestration of the silica nanoparticles in the polymeric domain of holographic polymer-dispersed liquid-crystals Bragg gratings. Here, excellent dispersion of the nanoparticles maintains the optical properties of the reflection grating without additional scattering while lowering the voltage necessary to switch the state of the grating.

36 MATERIALS SCIENCE↗

Generation of two-color terahertz radiation using Smith–Purcell emitter and periodic dielectric layers

This paper proposes and simulates three vacuum state devices each of which generates two-color terahertz radiation by Smith–Purcell emitter and dielectric layers. Each of the devices is a SiO{sub 2}-made vacuum tube consisting of a Smith–Purcell emitter located at the bottom of the tube and also periodic dielectric layers located at the top. Smith–Purcell structure is a metal grating above which electron beam is generated closely by the cathode and are collected by a collector in another side of the grating. The emitter generates two terahertz radiations including evanescent and coherent Smith–Purcell radiations. While the evanescent radiation is the first harmonic of the emitted radiation, coherent Smith–Purcell radiation is the second and dominant one. The coherent Smith–Purcell radiation is emitted in a specific angle calculated by Smith–Purcell relation. The emitted coherent Smith–Purcell radiation coincides with periodic grating dielectric layers made of Si and SiO{sub 2} on top of the vacuum tube, and the transmitted pulse is transformed to two-terahertz pulses. The output of each device is a two-color terahertz pulse. Two generated terahertz wavelengths are very applicable in pump–probe experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and fabrication of ring resonator spectral response through-drop wavelengths selective

In this paper, we discuss the basic characteristics of the SOI based micro-ring resonator, and understand the influence of the high refractive index difference and the small size on the spectral characteristics of the ring resonator. The novelty and importance of the spectral response selectivity of ring resonators is driven by the grating couple technique. This advantage is the periodic variation of the refractive index in the coupled grating, which will result in the coupling of the conduction wave modes. By means of measurement and simulation, observe the changes and trends of the spectrum in steady state and transient state, and finally analyze the performance of the ring resonator in the application of signal processing. It achieves polarization-independent grating couplers with high efficiency, wide bandwidth and low polarization-dependent loss at around the 1560 nm optical communication band. Drop end set laser wavelength correction 1591.9 nm.

36 MATERIALS SCIENCE↗