At least 1,369 records · Page 76

The DOE E3SM Coupled Model Version 1: Description and Results at High Resolution

This study provides an overview of the coupled high-resolution Version 1 of the Energy Exascale Earth System Model (E3SMv1) and documents the characteristics of a 50-year-long high-resolution control simulation with time-invariant 1950 forcings following the HighResMIP protocol. In terms of global root-mean-squared error metrics, this high-resolution simulation is generally superior to results from the low-resolution configuration of E3SMv1 (due to resolution, tuning changes, and possibly initialization procedure) and compares favorably to models in the CMIP5 ensemble. Ocean and sea ice simulation is particularly improved, due to better resolution of bathymetry, the ability to capture more variability and extremes in winds and currents, and the ability to resolve mesoscale ocean eddies. The largest improvement in this regard is an ice-free Labrador Sea, which is a major problem at low resolution. Interestingly, several features found to improve with resolution in previous studies are insensitive to resolution or even degrade in E3SMv1. Most notable in this regard are warm bias and associated stratocumulus deficiency in eastern subtropical oceans and lack of improvement in El Niño. Another major finding of this study is that resolution increase had negligible impact on climate sensitivity (measured by net feedback determined through uniform +4K prescribed sea surface temperature increase) and aerosol sensitivity. Cloud response to resolution increase consisted of very minor decrease at all levels. Large-scale patterns of precipitation bias were also relatively unaffected by grid spacing.

54 ENVIRONMENTAL SCIENCES↗

Impact of Uncoordinated Plug-in Electric Vehicle Charging on Residential Power Demand

Electrification of transport offers opportunities to increase energy security, reduce carbon emissions, and improve local air quality. Plug-in electric vehicles (PEVs) are creating new connections between the transportation and electric sectors, and PEV charging will create opportunities and challenges in a system of growing complexity. Here, I use highly resolved models of residential power demand and PEV use to assess the impact of uncoordinated in-home PEV charging on residential power demand. While the increase in aggregate demand might be minimal even for high levels of PEV adoption, uncoordinated PEV charging could significantly change the shape of the aggregate residential demand, with impacts for electricity infrastructure, even at low adoption levels. Clustering effects in vehicle adoption at the local level might lead to high PEV concentrations even if overall adoption remains low, significantly increasing peak demand and requiring upgrades to the electricity distribution infrastructure. This effect is exacerbated when adopting higher in-home power charging.

33 ADVANCED PROPULSION SYSTEMS↗

Performance and Health Test Procedure for Grid Energy Storage Systems

A test procedure to evaluate the performance and health of field installations of grid-connected battery energy storage systems (BESS) is described. Performance and health metrics captured in the procedures are: round-trip efficiency, standby losses, response time/accuracy, and useable energy/state of charge at different discharge/charge rates over the system's lifetime. The procedures are divided into reference performance tests, which require the system to be put in a test mode and are to be conducted in intervals, and real-time monitoring tests, which collect data during normal operation without interruption. The procedures can be applied on a wide array of BESS with little modification and can thus support BESS operators in the management of BESS field installations with minimal interruption and expenditure. Simulated results based on a detailed system simulation of a prototype system are provided as guideline.

25 ENERGY STORAGE↗

Cost Estimation of a Permanent Magnet Synchronous Machine for Use in Adjustable Speed-Pumped Storage Hydropower

Electric machine design has become an easier process with the availability of computers in recent decades. However, the interest in electric machine design among students has declined. University-level design courses must compete with courses perceived as more desirable by the potential job market. Hence, the power system engineers with this expertise are very few and are nearing retirement. Contrarily, renewable energy has been picking up in the past few decades. The indeterminacy and variation of renewable energy sources require a balancing mechanism to maintain the constant voltage and frequency of the grid. Adjustable-Speed Pumped-Storage Hydropower plants are considered the contender for future energy storage, providing large capacity and fast-acting response. Large-scale hydropower applications depend on the natural characteristics of each project site, making less expensive, off-the-shelf generators unfeasible. This work gives a shortcut to estimate the cost of constructing a permanent magnet generator for low-volume manufacturing.

13 HYDRO ENERGY↗

Polyvinyl Chloride/Silica Nanoporous Composite Separator for All-Vanadium Redox Flow Battery Applications

Redox flow batteries (RFBs) are capable of reversible conversion between electricity and chemical energy. Potential RFB applications resolve around mitigating the discrepancy between electricity production and consumption to improve the stability and utilization of the power infrastructure and tackling the intermittency of renewables such as photovoltaics or wind turbines to enable their reliable integration [1, 2]. Because the energy is stored in externally contained liquid electrolytes and the energy conversion reactions take place at the electrodes, RFBs hold a unique capability to separate energy and power and thus possess considerable design flexibility to meet either energy management driven or power rating oriented grid applications, which is considered to be a unparalleled advantage over conventional solid-state secondary batteries [3]. Other advantages of RFBs include fast response to load changes, high round-trip efficiency, long calender and cycle lives, safe operations, tolerance to deep discharge, etc. [4]. Among various flow battery chemistries, all-vanadium redox flow battery (VRB) was invented by Maria Skyllas-Kazacos at the University of New South Wales in the 1980s [5, 6] and have attracted substantial attention in both research and industrial communities today [7, 8]. A well-recognized advantage that makes VRB stands out among other redox chemistries is the reduced crossover contamination ascribed to employing four different oxidation states of the same vanadium element as the two redox couples. Recently, great progress has led to remarkably improved energy density of VRB by using sulfuric-chloric mixed acid supporting electrolytes that were stable at 2.5M vanadium and had wider operational temperature window of -5~50oC [9], compared with the traditional sulfuric acid VRB system [10].

Wei, Xiaoliang↗

Current Developments in Retail Rate Design: Implications for Solar and Other Distributed Energy Resources

Retail electricity pricing is evolving in the context of broader shifts in how electricity customers pay for grid services and how they are compensated for customer-sited generation. This evolution has been prompted by a broad set of factors, chief among them being: widespread adoption of advanced metering infrastructure (AMI), increased customer investment in solar and other distributed energy resources (DERs), concerns about utilities’ fixed cost recovery and revenue sufficiency in an era of flat or declining load growth, and significant changes to utilities’ hourly net load profiles and operational needs as greater amounts of variable renewable energy (VRE) resources connect to the grid. This report discusses five current retail rate design trends among residential and commercial customer classes that have emerged, at least in part, in response to those drivers, and uses case studies to illustrate key motivations, variations in rate design, and aspects of implementation experience.

14 SOLAR ENERGY↗

Experimental Development and Physical Analysis of Jet and Vortex Actuators

The Vortex generator consists of a cavity with a lightweight actuator plate. The actuator plate acts like a piston pumping air out of the cavity on the down-stroke and sucking air into the cavity on the upstroke. The actuator is placed asymmetrically over the cavity opening, forming narrow and wide slots when viewed from the top. The actuator depending on amplitude, frequency, and slot spacing produces several flow fields (free jet, wall jet, vortex flow). Computational simulation of the actuator-generated flows have been developed and applied to several actuator flow modes. The objectives of this paper are to study the physics of the actuator-induced flow and to develop computational simulations of the actuatorgenerated flows. This work should provide an impetus for designing similar active flow control systems suitable for aircraft applications. The computational simulation uses a time-accurate full Navier-Stokes (NS) solver known as FTNS3D (a full NS version of CFL3D solver). A Multi-block moving grid has been developed and used for the computational study of the flow fields produced by the vortex generator. For three-dimensional computations, ten multi-block grids are used and for two-dimensional computations, six multiblock grids are used. The grid blocks adjacent to the actuator plate move with the plate motion, and second-order interpolation is used along the block interfaces. Periodic response of the flow has been observed to develop after three cycles of the plate sinusoidal motion.

Kandil, Osama A.↗

Magnetotail Current Sheet Thinning and Magnetic Reconnection Dynamics in Global Modeling of Substorms

Magnetotail current sheet thinning and magnetic reconnection are key elements of magnetospheric substorms. We utilized the global MHD model BATS-R-US with Adaptive Mesh Refinement developed at the University of Michigan to investigate the formation and dynamic evolution of the magnetotail thin current sheet. The BATSRUS adaptive grid structure allows resolving magnetotail regions with increased current density up to ion kinetic scales. We investigated dynamics of magnetotail current sheet thinning in response to southwards IMF turning. Gradual slow current sheet thinning during the early growth phase become exponentially fast during the last few minutes prior to nightside reconnection onset. The later stage of current sheet thinning is accompanied by earthward flows and rapid suppression of normal magnetic field component $B-z$. Current sheet thinning set the stage for near-earth magnetic reconnection. In collisionless magnetospheric plasma, the primary mechanism controlling the dissipation in the vicinity of the reconnection site is non-gyrotropic effects with spatial scales comparable with the particle Larmor radius. One of the major challenges in global MHD modeling of the magnetotail magnetic reconnection is to reproduce fast reconnection rates typically observed in smallscale kinetic simulations. Bursts of fast reconnection cause fast magnetic field reconfiguration typical for magnetospheric substorms. To incorporate nongyritropic effects in diffusion regions we developed an algorithm to search for magnetotail reconnection sites, specifically where the magnetic field components perpendicular to the local current direction approaches zero and form an X-type configuration. Spatial scales of the diffusion region and magnitude of the reconnection electric field are calculated self-consistently using MHD plasma and field parameters in the vicinity of the reconnection site. The location of the reconnection sites and spatial scales of the diffusion region are updated during the simulations. Such an approach allows quantifying the interaction between large-scale global magnetospheric dynamics and microphysical processes in diffusion regions localized near reconnection sites. To clarify the role of smallscale non-MHD effects in diffusion region on the global magnetospheric dynamic and to test different models of dissipation we perform simulations with steady southward IMF driving of the magnetosphere.

Kuznetsova, M. M.↗

Formation of the Lyman Continuum during Solar Flares

The Lyman continuum (LyC; <911.12 Å) forms at the top of the chromosphere in the quiet Sun, making LyC a powerful tool for probing the chromospheric plasma during solar flares. To understand the effects of nonthermal energy deposition in the chromosphere during flares, we analyzed LyC profiles from a grid of field-aligned radiative-hydrodynamic models generated using the RADYN code as part of the F-CHROMA project. The spectral response of LyC, the temporal evolution of the departure coefficient of hydrogen, b 1 , and the color temperature, T c , in response to a range of nonthermal electron distribution functions, were investigated. The LyC intensity was seen to increase by 4–5.5 orders of magnitude during solar flares, responding most strongly to the nonthermal electron flux of the beam. Generally, b 1 decreased from 10 2 –10 3 to closer to unity during solar flares, indicating a stronger coupling to local conditions, while T c increased from 8–9 to 10–16 kK. T c was found to be approximately equal to the electron temperature of the plasma when b1 was at a minimum. Both optically thick and optically thin components of LyC were found to be in agreement with the interpretation of recent observations. The optically thick layer forms deeper in the chromosphere during a flare compared to quiescent periods, whereas the optically thin layers form at higher altitudes due to chromospheric evaporation, in low-temperature, high-density regions propagating upward. We put these results in the context of current and future missions.

Solar flares↗

Performance and Health Test Procedure for Grid Energy Storage Systems: Preprint

A test procedure to evaluate the performance and health of field installations of grid-connected battery energy storage systems (BESS) is described. Performance and health metrics captured in the procedures are: Round-trip efficiency, Standby losses, Response time/accuracy, and Useable Energy/ State of Charge at different discharge/charge rates over the system's lifetime. The procedures are divided into Reference Performance Tests, which require the system to be put in a test mode and are to be conducted in intervals, and Real-time Monitoring tests, which collect data during normal operation without interruption. The procedures can be applied on a wide array of BESS with little modifications and can thus support BESS operators in the management of BESS field installations with minimal interruption and expenditures.can be applied on a wide array of BESS with little modifications and can thus support BESS operators in the management of BESS field installations with minimal interruption and expenditures.

25 ENERGY STORAGE↗

Atmospheric River Frequency-Category Characteristics Shape U.S. West Coast Runoff

Abstractrunoff response to atmospheric rivers (ARs) over the U.S. West Coast. We focused on runoff time series variations impacted by AR characteristics (e.g., category and frequency) and land preconditions during Northern Hemisphere cool seasons in the period of 1940–2023. Results show that high-category ARs significantly increase local runoff with higher hourly precipitation rates leading to a greater incremental rate and peak runoff. Extreme runoff increases greatly with the AR category with an increase rate up to 12.5 times stronger than non-extreme runoff. Besides the AR category, land preconditions such as soil moisture and snowpack also play crucial roles in modulating runoff response. We found that runoff induced by weak-category ARs is more sensitive to land preconditions than high-category ARs, with high peak runoff occurring when soil is nearly saturated. Additionally, more than 50% of high-peak-runoff events in snow-covered grid cells are associated with rain-on-snow events particularly for the events associated with weaker ARs. Regression analysis reveals that AR precipitation and land preconditions jointly influence runoff, emphasizing the importance of including soil moisture and snowpack levels in AR impact assessments. The study also highlights the intensified runoff response to back-to-back ARs with short intervals, which may become more frequent with climate warming, posing increased flood risks via facilitating wet soil conditions. Our findings have significant implications for AR risk predictions and the development of prediction models for AR-induced runoff.

54 ENVIRONMENTAL SCIENCES↗

Design and Prototyping of Advanced Control Systems for Advanced Reactors Operating in the Future Electric Grid (Final Report)

Despite its significant advantages as a baseload, low-carbon energy source, the U.S. nuclear power industry has faced increasing difficulties in maintaining economic competitiveness in a rapidly evolving energy market. The economic conditions faced by the current fleet of nuclear power plants (NPPs) in the U.S. deregulated electricity market require a concerted effort to mitigate specific cost factors. Many units are struggling to stay competitive, and some premature shutdowns have occurred. Besides, in response to the large penetration of renewable energy sources, the role of nuclear power plants as pure baseload units needs to be reconsidered. Based on these experiences, operational flexibility is considered a fundamental requirement for the next generation of nuclear reactors to be competitive in the future energy market. The deployment of advanced reactors capable of operating within a new power grid paradigm, known as the Integrated Energy System (IES) was investigated. This approach combines new reactor designs with Thermal Energy Storage (TES) technologies, allowing the nuclear reactor to maintain a steady power output without the need for constant adjustments in response to load demand fluctuations. With this configuration, the reactor operates as a baseload unit, experiencing only very gradual power transients, while the energy storage facility within the power conversion cycle acts as a peaking unit.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Multiyear Gridded Data Ensemble of Surface Biogenic Carbon Fluxes for North America: Evaluation and Analysis of Results

Accurate and fine-scale estimates of biogenic carbon fluxes are critical for measuring and monitoring the biosphere's responses and feedback to the climate system. Currently available data products from flux towers and model-intercomparison projects struggle to adequately represent spatiotemporal dynamics of surface biogenic carbon fluxes, and to quantify their uncertainties, which also are crucial to atmospheric inversion systems. To address these gaps, we introduce a new perturbed-parameter model ensemble with the CASA model to estimate surface biogenic carbon fluxes at monthly and 3-hourly scales for North America at ~500-m and 5-km resolutions. We first use the Extended Fourier Amplitude Sensitivity Testing to choose the three most sensitive parameters to be perturbed, maximum light use efficiency (E max ), optimal temperature of photosynthesis (T opt ), and temperature response of respiration (Q 10 ). The initial range for each parameter is broadly sampled for the L1 ensemble, but then we pruned E max with site-level primary productivity to derive an L2 ensemble with narrower uncertainty ranges. Ensembles are strongly correlated with site-level results at both monthly and 3-hourly scales, and the spread across L1/L2 ensemble members encompasses the range of AmeriFlux observations. Monthly variability in the L2 ensemble mean is 85% of the observed variability. The L2 ensemble outperforms diverse data products with the highest Taylor skill scores at diurnal to annual scales. Finally, the ensemble's seasonality agrees well with other models for most biome types and in high and middle latitudes, but inconsistencies are found in subtropical and tropical ecoregions and for annual totals over North America.

54 ENVIRONMENTAL SCIENCES↗

Real-Time Testbed for Studying Cyberattacks and Defense in DER-integrated Smart Inverter Systems

In this paper, we propose a Hardware-in-the-Loop (HIL) simulation testbed suitable for the implementation and testing of realistic cyberattacks on grid-tied smart inverter systems integrated with Distributed Energy Resources (DER) that use the Distributed Network Protocol-3 (DNP3) protocol for communications between grid components. Specifically, our testbed combines a Real-Time Digital Simulator (RTDS) NovaCor device, outfitted with GNETx2 network interface cards, a gridtied DER topology implemented via the RTDS software package RSCAD, and a custom virtual network that emulates a man in the middle attacker. The Man-in-the-Middle (MITM) attacker captures DNP3 traffic and falsifies telemetry data in DNP3 packets to trigger unwarranted commands from a DNP3 controller that exploit smart inverter grid support functions. We choose DNP3 and implement grid support functions according to the IEEE Std. 1547-2018 mandated for the interconnection and interoperability of DER power systems with associated power components. Furthermore, we develop a protocol payload agnostic attack detection framework that leverages the round-trip time (RTT) anomalies between DNP3 requests and responses and can detect the presence of attacks without having to analyze the payload’s contents, while balancing trade-offs between false alarm counts, missed detections, and time to detection. To facilitate further research, we publicly release benign and attack network traffic exchanged between various sensors, controllers, and actuators in our grid-tied inverter testbed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Commercial and Industrial Base Intermittent Resource Management Pilot

This scoping study summarizes the challenges with integrating wind and solar generation into the California's electricity grid. These challenges include: Smoothing intra-hour variability; - Absorbing excess renewable energy during over-generation periods; - Addressing morning and evening ramping periods. In addition, there are technical challenges to integrating retail demand response (DR) triggered by the wholesale conditions into the CAISO markets. The study describes the DR programs available to the consumers through the utilities in California and CAISO's ancillary services market because an integration of the wholesale and retail DR requires an understanding of these different offerings and the costs associated with acquiring them. Demand-side active and passive storage systems are proposed as technologies that may be used to mitigate the effects of intermittence due to renewable generation. Commercial building technologies as well as industrial facilities with storage capability are identified as targets for the field tests. Two systems used for ancillary services communications are identified as providing the triggers for DR enablement. Through the field tests, issues related to communication, automation and flexibility of demand-side resources will be explored and the performance of technologies that participate in the field tests will be evaluated. The major outcome of this research is identifying and defining flexibility of DR resources and optimized use of these resources to respond to grid conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigating Oscillations in Bulb Turbine Plant During Islanded black start Operation

This paper investigates the frequency oscillatory behavior displayed by the bulb turbine-based run-of-river (ROR) hydropower system under islanded operation. These oscillations prevent higher loading of these generators (under islanded conditions) and hence reduce the black start capability of these generators. To investigate the problem, first, a transfer function model of the bulb-turbine system, sensitive to the effects of head variation, blade angle, and other non-linearities pertaining to turbine characteristics is derived. Next, by analyzing this transfer function model and through simulations, it is determined that system inertia along with other parameters could be responsible for these oscillations. Also, through simulations it is shown that the same ROR system’s behavior is different under islanded mode compared to grid-connected mode.

13 HYDRO ENERGY↗

Multi-Agent Simulation Based Framework for Power Restoration Time Estimation at Distribution Level

The growing frequency of power outages has prompted increased interest in developing a more resilient power grid that can quickly recover from weather-related damage. At the distribution level, power restoration is a complex, multi-stage process involving multiple response entities. Providing utility stakeholders, government regulators, and the public with information about outage duration and estimated time to restoration is crucial. The research employs a multi-agent simulation approach, which allows for the simulation of decision-making behaviors among different entities and the incorporation of various uncertainties. Specifically, the study uses the open-source simulation package Mesa-Geo in conjunction with the Python language and constructs a road network using the open-source network extension pgRouting for routing queries. The research design includes several experiments focused on Florida as a case study, comparing repair crew sizes, power outage numbers, and road damage scenarios. The findings could offer valuable managerial guidance on resource allocation in the restoration process.

Chen, Yang↗

Transactive Approach for Engaging Distribution Network Assets for Voltage Management in Southern California Edison Distribution Feeders

This report documents an effort by Pacific Northwest National Laboratory (PNNL) investigating the utility of using incentive signals to elicit useful responses from smart inverters associated with customer-owned distributed energy resources (DERs). This project was an element of the Southern California Edison (SCE) Integrated Grid Project (IGP) funded by the California Public Utilities Commission’s (CPUC’s) Electric Program Investment Charge (EPIC) program (CPUC 2018) to support applied research and development, technology demonstration and deployment, and the market facilitation of clean energy technologies and approaches.

24 POWER TRANSMISSION AND DISTRIBUTION↗