Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid simulator testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

RLC4CLR (Reinforcement Learning Controller for Critical Load Restoration Problems)

RLC4CLR demonstrates using a reinforcement learning controller (RLC) to solve a critical load restoration (CLR) problem, which improves the grid resilience after a substation outage event. RLC4CLR consists of two parts. (1) RL environment: This environment encapsulates the CLR problem to be solved and provides interfacing functions to follow the standard OpenAI Gym format. A power system simulator, i.e., OpenDSS, is included to provide the power flow solution. Controller inputs and outputs (RL state and action) as well as the reward are defined in this environment as well. In summary, the RL environment is the problem formulation from which the RL agent can learn. (2) RL training script: The training script enables the RL agent to learn its control policy by interacting with the RL environment. For RL training, an open-sourced RL library, i.e., RLlib, is leveraged which is based on a distributed computing framework (Ray). The training script is designed to be able to be run on both local machine or the NREL HPC system. Other components of RLC4CLR include input data, e.g., grid model (standard IEEE test feeders), and other files used for results analysis.

Zhang, Xiangyu↗

High-Performance Integrated Window and Façade Solutions for California

The researchers developed a new generation of high-performance façade systems and supporting design and management tools to support industry in meeting California’s greenhouse gas reduction targets, reduce energy consumption, and enable an adaptable response to minimize real-time demands on the electricity grid. The project resulted in five outcomes: (1) The research team developed an R-5, 1-inch thick, triplepane, insulating glass unit with a novel low-conductance aluminum frame. This technology can help significantly reduce residential cooling and heating loads, particularly during the evening. (2) The team developed a prototype of a windowintegrated local ventilation and energy recovery device that provides clean, dry fresh air through the façade with minimal energy requirements. (3) A daylight-redirecting louver system was prototyped to redirect sunlight 15–40 feet from the window. Simulations estimated that lighting energy use could be reduced by 35–54 percent without glare. (4) A control system incorporating physics-based equations and a mathematical solver was prototyped and field tested to demonstrate feasibility. Simulations estimated that total electricity costs could be reduced by 9-28 percent on sunny summer days through adaptive control of operable shading and daylighting components and the thermostat compared to state-of-the-art automatic façade controls in commercial building perimeter zones. (5) Supporting models and tools needed by industry for technology R&D and market transformation activities were validated. Attaining California’s clean energy goals require making a fundamental shift from today’s ad-hoc assemblages of static components to turnkey, intelligent, responsive, integrated building façade systems. These systems offered significant reductions in energy use, peak demand, and operating cost in California.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Convective Systems Over the South China Sea: Cloud-Resolving Model Simulations

The South China Sea Monsoon Experiment (SCSMEX) was conducted in May-June 1998. One of its major objectives is to better understand the key physical processes for the onset and evolution of the summer monsoon over Southeast Asia and southern China. Multiple observation platforms (e.g., upper-air soundings, Doppler radar, ships, wind profilers, radiometers, etc.) during SCSMEX provided a first attempt at investigating the detailed characteristics of convective storms and air pattern changes associated with monsoons over the South China Sea region. SCSMEX also provided rainfall estimates which allows for comparisons with those obtained from the Tropical Rainfall Measuring Mission (TRMM), a low earth orbit satellite designed to measure rainfall from space. The Goddard Cumulus Ensemble (GCE) model (with 1-km grid size) is used to understand and quantify the precipitation processes associated with the summer monsoon over the South China Sea. This is the first (loud-resolving model used to simulate precipitation processes in this particular region. The GCE-model results captured many of the observed precipitation characteristics because it used a fine grid size. For example, the temporal variation of the simulated rainfall compares quite well to the sounding-estimated rainfall variation. The time and domain-averaged temperature (heating/cooling) and water vapor (drying/ moistening) budgets are in good agreement with observations. The GCE-model-simulated rainfall amount also agrees well with TRMM rainfall data. The results show there is more evaporation from the ocean surface prior to the onset of the monsoon than after the on-~et of monsoon when rainfall increases. Forcing due to net radiation (solar heating minus longwave cooling) is responsible for about 25% of the precipitation in SCSMEX The transfer of heat from the ocean into the atmosphere does not contribute significantly to the rainfall in SCSMEX. Model sensitivity tests indicated that total rain production is reduced 17-18% in runs neglecting the ice phase. The SCSMEX results are compared to other GCE-model-simulated weather systems that developed during other field campaigns (i.e., west Pacific warm pool region, eastern Atlantic region and central USA). Large-scale forcing vie temperature and water vapor tendency, is the major energy source for net condensation in the tropical cases. The effects of large-scale cooling exceed that of large-scale moistening in the west pacific warm pool region and eastern Atlantic region. For SCSMEX, however, the effects of large-scale moistening predominate. Net radiation and sensible and latent hc,it fluxes play a much more important role in the central USA.

Tao, Wei-Kuo↗

DSMC Simulations of Hypersonic Flows With Shock Interactions and Validation With Experiments

The capabilities of a relatively new direct simulation Monte Carlo (DSMC) code are examined for the problem of hypersonic laminar shock/shock and shock/boundary layer interactions, where boundary layer separation is an important feature of the flow. Flow about two model configurations is considered, where both configurations (a biconic and a hollow cylinder-flare) have recent published experimental measurements. The computations are made by using the DS2V code of Bird, a general two-dimensional/axisymmetric time accurate code that incorporates many of the advances in DSMC over the past decade. The current focus is on flows produced in ground-based facilities at Mach 12 and 16 test conditions with nitrogen as the test gas and the test models at zero incidence. Results presented highlight the sensitivity of the calculations to grid resolution, sensitivity to physical modeling parameters, and comparison with experimental measurements. Information is provided concerning the flow structure and surface results for the extent of separation, heating, pressure, and skin friction.

Moss, James N.↗

DSMC Simulations of Hypersonic Flows With Shock Interactions and Validation With Experiments

The capabilities of a relatively new direct simulation Monte Carlo (DSMC) code are examined for the problem of hypersonic laminar shock/shock and shock/boundary layer interactions, where boundary layer separation is an important feature of the flow. Flow about two model configurations is considered, where both configurations (a biconic and a hollow cylinder-flare) have recent published experimental measurements. The computations are made by using the DS2V code of Bird, a general two-dimensional/axisymmetric time accurate code that incorporates many of the advances in DSMC over the past decade. The current focus is on flows produced in ground-based facilities at Mach 12 and 16 test conditions with nitrogen as the test gas and the test models at zero incidence. Results presented highlight the sensitivity of the calculations to grid resolutions, sensitivity to physical modeling parameters, and comparison with experimental measurements. Information is provided concerning the flow structure and surface results for the extent of separation, heating, pressure, and skin friction.

Moss, James N.↗

Co-Simulation of PSS/E, OpenDSS, and PSCAD for Power Systems Stability Analysis With Inverter-Based Resources: Preprint

The increasing penetration of inverter-based resources (IBRs) is reshaping the dynamic behavior of power systems. IEEE standard 1547-2018 suggests that distributed energy resources (DERs) should provide grid services such as voltage and frequency supports. On the other hand, dynamic events caused by IBRs such as sub-synchronous oscillation have been reported. These developments necessitate improvement in the current modeling capabilities to better understand the interdependencies within power systems. These include interactions between transmission and distribution systems, among IBRs themselves, and between IBRs and conventional resources. In this paper, we present a co-simulation model integrating PSS/E, OpenDSS, and PSCAD to analyze IBR impacts on the stability of transmission and distribution systems. A key challenge in developing a co-simulation model is ensuring interoperability among different simulators (interfacing and data flow) while maintaining accurate results. Using the developed model, we simulate the impact of IBRs on power systems in two test cases: 1) fault ride through (FRT) capability during a generation trip contingency; 2) IBR-induced sub-synchronous oscillation. The results show the effectiveness of the co-simulation model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling subgrid combustion processes in simulations of thermonuclear supernovae

Supernovae of type Ia are thought to arise from the thermonuclear incineration of a carbon-oxygen white dwarf stellar remnant. However, the detailed explosion scenario and stellar evolutionary origin scenario – or scenarios – which lead to observed supernovae are still quite uncertain. One of the principal tests of proposed scenarios is comparison with the explosion products inferred, for example, from the spectrum of the supernovae. Making this comparison requires computation of the combustion dynamics and products through simulation of proposed scenarios. Here we discuss two specific proposed explosion scenarios, the deflagration-detonation transition and the helium shell double detonation, With these two examples in mind, we proceed to discuss challenges to computational modeling of the combustion taking place in these explosions. Both subsonically and supersonically propagating reaction fronts are discussed,called deflagrations and detonations respectively. Several major stages of the combustion occur on length and time scales that are many orders of magnitude smaller than those accessible in simulations of the explosion. Models which attempt to capture this sub-grid behavior and the verification of those models is briefly discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Fault-Tolerant Decentralized Control for Large-Scale Inverter-Based Resources for Active Power Tracking

Integration of inverter-based resources (IBRs) which lack the intrinsic characteristics such as the inertial response of the traditional synchronous-generator (SG)-based sources presents a new challenge in the form of analyzing the grid stability under their presence. While the dynamic composition of IBRs differs from that of the SGs, the control objective remains similar in terms of tracking the desired active power. This letter presents a decentralized primal-dual-based fault-tolerant control framework for the power allocation in IBRs. Overall, a hierarchical control algorithm is developed with a lower level addressing the current control and the parameter estimation for the IBRs and the higher level acting as the reference power generator to the low level based on the desired active power profile. The decentralized network-based algorithm adaptively splits the desired power between the IBRs taking into consideration the health of the IBRs transmission lines. The proposed framework is tested through a simulation on the network of IBRs and the high-level controller performance is compared against the existing framework in the literature. The proposed algorithm shows significant performance improvement in the magnitude of power deviation and settling time to the nominal value under faulty conditions as compared to the algorithm in the literature.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High Resolution Aerospace Applications using the NASA Columbia Supercomputer

This paper focuses on the parallel performance of two high-performance aerodynamic simulation packages on the newly installed NASA Columbia supercomputer. These packages include both a high-fidelity, unstructured, Reynolds-averaged Navier-Stokes solver, and a fully-automated inviscid flow package for cut-cell Cartesian grids. The complementary combination of these two simulation codes enables high-fidelity characterization of aerospace vehicle design performance over the entire flight envelope through extensive parametric analysis and detailed simulation of critical regions of the flight envelope. Both packages. are industrial-level codes designed for complex geometry and incorpor.ats. CuStomized multigrid solution algorithms. The performance of these codes on Columbia is examined using both MPI and OpenMP and using both the NUMAlink and InfiniBand interconnect fabrics. Numerical results demonstrate good scalability on up to 2016 CPUs using the NUMAIink4 interconnect, with measured computational rates in the vicinity of 3 TFLOP/s, while InfiniBand showed some performance degradation at high CPU counts, particularly with multigrid. Nonetheless, the results are encouraging enough to indicate that larger test cases using combined MPI/OpenMP communication should scale well on even more processors.

Mavriplis, Dimitri J.↗

Impact of Blockchain Delay on Grid-Tied Solar Inverter Performance: Preprint

This paper investigates the impact of the delay resulting from a blockchain, a promising security measure, for a hierarchical control system of inverters connected to the grid. The blockchain communication network is designed at the secondary control layer for resilience against cyberattacks. To represent the latency in the communication channel, a model is developed based on the complexity of the blockchain framework. Taking this model into account, this work evaluates the plant’s performance subject to communication delays, introduced by the blockchain, among the hierarchical control agents. In addition, this article considers an optimal model-based control strategy that performs the system’s internal control loop. The work shows that the blockchain’s delay size influences the convergence of the power supplied by the inverter to the reference at the point of common coupling. In the results section, real-time simulations on OPAL-RT are performed to test the resilience of two parallel inverters with increasing blockchain complexity.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Compact millimeter-wavelength Fourier-transform spectrometer

Here, we have constructed a Fourier-transform spectrometer (FTS) operating between 50 GHz and 330 GHz with minimum volume (355×260×64 mm) and weight (5.9 kg) while maximizing optical throughput (100 mm 2 sr) and optimizing the spectral resolution (4 GHz). This FTS is designed as a polarizing Martin–Puplett interferometer with unobstructed input and output in which both input polarizations undergo interference. The instrument construction is simple with mirrors milled on the box walls and one motorized stage as the single moving element. We characterize the performance of the FTS, compare the measurements to an optical simulation, and discuss features that relate to details of the FTS design. The simulation is also used to determine the tolerance of optical alignments for the required specifications. We detail the FTS mechanical design and provide the control software as well as the analysis code online.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Self-induced temperature correction for inter-phase heat transfer in Euler-Lagrange point-particle simulation

In a two-way coupled Euler-Lagrange simulation, particles are approximated as point sources and their momentum and energy exchange with the surrounding flow are modeled through point-particle force and heat transfer models. As the particle size increases and approaches the Eulerian grid, the feedback force and heat transfer become large and strongly affect the local flow at the particle location. The fluid velocity and temperature computed in the EL simulation when interpolated to the particle location will be substantially different from the corresponding undisturbed values. In this work we will follow the approach pursued in Balachandar et al. (2018) [1] for self-induced velocity correction to develop an analogous correction procedure for self-induced temperature. We obtain analytical solutions for the self-induced thermal perturbation for a steady uniform cross flow past a Gaussian filtered heat source under both steady and unsteady conditions. The analytical results are extended to finite Peclet number using numerical simulations. The resulting quasi-steady and unsteady models are tested with a simple problem of exponential thermal evolution against the corresponding EL simulation results. We also provide a simple criterion for when the self-induced temperature correction is needed in an Euler-Lagrange simulation.

42 ENGINEERING↗

Staggered scheme for the compressible fluctuating hydrodynamics of multispecies fluid mixtures

Here, we present a numerical formulation for the solution of nonisothermal, compressible Navier-Stokes equations with thermal fluctuations to describe mesoscale transport phenomena in multispecies fluid mixtures. The novelty of our numerical method is the use of staggered grid momenta along with a finite volume discretization of the thermodynamic variables to solve the resulting stochastic partial differential equations. The key advantages of the numerical scheme are that it significantly simplifies the discretization of diffusive and stochastic momentum fluxes into a more compact form, and it provides an unambiguous prescription of boundary conditions involving pressure. The staggered grid scheme more accurately reproduces the equilibrium static structure factor of hydrodynamic fluctuations in gas mixtures compared to a collocated scheme described previously by Balakrishnan et al. [Phys. Rev. E 89, 013017 (2014)1539-375510.1103/PhysRevE.89.013017]. The numerical method is tested for ideal noble gases mixtures under various nonequilibrium conditions, such as applied thermal and concentration gradients, to assess the role of cross-diffusion effects, such as Soret and Dufour, on the long-ranged correlations of hydrodynamic fluctuations, which are also more accurately reproduced compared to the collocated scheme. We numerically study giant nonequilibrium fluctuations driven by concentration gradients and fluctuation-driven Rayleigh-Taylor instability in gas mixtures. Wherever applicable, excellent agreement is observed with theory and measurements from the direct simulation Monte Carlo method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Unintentional Islanding Detection Performance with Mixed DER Types

Most inverters for use in distribution-connected distributed energy resource applications (distributed generation and energy storage) are tested and certified to detect and cease to energize unintentional islands on the electric grid. The requirements for the performance of islanding detection methods are specified in IEEE 1547-2018, and specified conditions for certification- type testing of islanding detection are defined in IEEE 1547.1. Such certification-type testing is designed to ensure a minimum level of confidence that these inverters will not island in field applications. However, individual inverter certification tests do not address interactions between dissimilar inverters or between inverter and synchronous machines that may occur in the field. This work investigates the performance of different inverter island detection methods for these two circumstances that are not addressed by the type testing: 1) combinations of different inverters using different types of islanding detection methods, and 2) combinations of inverters and synchronous generators. The analysis took into consideration voltage and frequency ride- through requirements as specified in IEEE 1547-2018, but did not consider grid support functionality such as voltage or frequency response. While the risk of islanding is low even in these cases, it is often difficult to deal with these scenarios in a simplified interconnection screening process. This type of analysis could provide a basis to establish a practical anti- islanding screening methodology for these complex scenarios, with the goal of reducing the number of required detailed studies. Eight generic Groups of islanding detection behavior are defined, and examples of each are used in the simulations. The results indicate that islanding detection methods lose effectiveness at significantly different rates as the composition of the distributed energy resources (DERs) varies, with some methods remaining highly effective over a wide range of conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Super Resolution of Remote Sensing Images Using Edge-Directed Radial Basis Functions

Edge-Directed Radial Basis Functions (EDRBF) are used to compute super resolution(SR) image from a given set of low resolution (LR) images differing in subpixel shifts. The algorithm is tested on remote sensing images and compared for accuracy with other well-known algorithms such as Iterative Back Projection (IBP), Maximum Likelihood (ML) algorithm, interpolation of scattered points using Nearest Neighbor (NN) and Inversed Distance Weighted (IDW) interpolation, and Radial Basis Functin(RBF) . The accuracy of SR depends on various factors besides the algorithm (i) number of subpixel shifted LR images (ii) accuracy with which the LR shifts are estimated by registration algorithms (iii) and the targeted spatial resolution of SR. In our studies, the accuracy of EDRBF is compared with other algorithms keeping these factors constant. The algorithm has two steps: i) registration of low resolution images and (ii) estimating the pixels in High Resolution (HR) grid using EDRBF. Experiments are conducted by simulating LR images from a input HR image with different sub-pixel shifts. The reconstructed SR image is compared with input HR image to measure the accuracy of the algorithm using sum of squared errors (SSE). The algorithm has outperformed all of the algorithms mentioned above. The algorithm is robust and is not overly sensitive to the registration inaccuracies.

Mareboyana, Manohar M.↗

Large-Scale Adoption of Self-Synchronized Universal Droop Controller-Based Inverters to Enable Ancillary Services for Different Modes of Distribution System Operations

This work proposes the large-scale adoption of self-synchronized universal droop controller (SUDC)-based inverters to enable ancillary services for different modes of distribution system operations. The IEEE 123 bus system was modeled on a real-time simulator to study the performance of large-scale adoption of SUDC inverters in a distribution system. The resulting data collected shows that the voltage and the frequency were regulated within ranges, such as less than 5% for voltage and less than 0.5% for frequency, under different load variations and grid operations. Also, the black start was achieved within 0.4 s without any voltage overshoot. Through the simulation and validation on a small microgrid and the IEEE 123 bus distribution system, it can be concluded that the SUDC was successfully adopted to regulate the voltage and the frequency within the given ranges, and black start achieved within 1 s without voltage overshoot for different modes of distribution system operations.

14 SOLAR ENERGY↗

A fourth-order Lagrangian discontinuous Galerkin method using a hierarchical orthogonal basis on curvilinear grids

The existing high-order Lagrangian discontinuous Galerkin (DG) hydrodynamic methods are restricted to using quadratic meshes with quadratic polynomials (P2), which in turn, yield up to third-order accuracy. Additionally, these existing DG hydrodynamic schemes, when extended to work with cubic meshes and cubic polynomials (P3), can be unstable on strong-shock problems. Therefore, this paper presents a new Lagrangian discontinuous Galerkin (DG) hydrodynamic method to simulate compressible material dynamics ( e.g., gasses, fluids, and solids) with strong-shocks using cubic meshes and cubic polynomials, and delivers up to fourth-order accuracy on smooth flows. The stability on shock problems is achieved using new hierarchical orthogonal basis functions and a new subcell mesh stabilization (SMS) scheme for cubic meshes. The accuracy and robustness of the new high-order accurate Lagrangian DG hydrodynamic method is demonstrated by simulating a diverse suite of challenging test problems covering gas and solid dynamic problems on curvilinear meshes.

97 MATHEMATICS AND COMPUTING↗

Immunity Study: Port Impedance Measurement of PMU and PCI testing under EMP

Phasor Measurement Units (PMUs) are critical for the Wide Area Measurement System (WAMS), especially for real-time grid monitoring, disturbance location, and situation awareness. Once they are damaged, the stable operation of the power system will be affected directly and greatly. Therefore, it is urgent and necessary to study their immunity to electromagnetic pulse (EMP) events. In this paper, an effective impedance measurement scheme is proposed for port impedance measurement of PMU. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Then circuit of pulsed current generator is established to generate damping sinusoid and double exponential wave applied to the port. Finally, by using measured impedance as a load of the generator, the voltage and current responses of different ports are calculated in the pulsed current injection (PCI) testing simulation. Results show that common-mode impedance is large and differential mode impedance is small. The critical condition will appear in the common mode for voltage and differential mode for current.

Zhang, Liang↗